G3RV-SL700-ADC24

G3RV-SL700-ADC24

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    模块

  • 描述:

    RELAYSSRSPST-NO2A24VDC

  • 数据手册
  • 价格&库存
G3RV-SL700-ADC24 数据手册
Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm • Long electrical life and high speed switching • Large plug-in terminals for reliable connection • G3RV-D (DC load) models can manage resistive loads of 100 µA to 3.0 A • LED indicator for visible operation checking • Convenient quick electrical connections possible with G3RV push-in models and cross bar connectors • Low power consumption for energy savings • G3RV is cUL listed when correct relay is matched with the G3RV Socket Model Number Structure ■ Model Number Legend G3RV-SL @ @ @ - @ 1 2 3 4 4. Output voltage specifications A(L): AC Output .. TRIAC *A: with Zero cross function AL: without Zero cross function D: DC Output .. MOS FET 1. Basic Model Name G3RV: Solid State Relay 2. Auxiliary Type Designation SL: Slim Solid State Relay and socket combination 3. Wire Connection 700: Screw Terminals 500: Push-in (screwless) terminals Ordering Information ■ List of Models Classification Enclosure rating Input voltage Type of connection Contact form SPST Plug-in terminals General-purpose Unsealed AC/DC Screw terminals G3RV-SL700 Push-in terminals G3RV-SL500 SSR and Socket Combinations Input voltage 12 VDC 24 VDC 24 VAC/DC 48 VAC/DC 110 VAC 230 VAC Screw terminals G3RV-SL700-D 12VDC Push-in terminals G3RV-SL500-D 12VDC G3RV-SL700-A(L) 12VDC G3RV-SL500-A(L) 12VDC G3RV-SL700-D 24VDC G3RV-SL500-D 24VDC G3RV-SL700-A(L) 24VDC G3RV-SL500-A(L) 24VDC G3RV-SL700-D 24VAC/DC G3RV-SL500-D 24VAC/DC G3RV-SL700-A(L) 24VAC/DC G3RV-SL500-A(L) 24VAC/DC G3RV-SL700-D 48VAC/DC G3RV-SL500-D 48VAC/DC G3RV-SL700-A(L) 48VAC/DC G3RV-SL500-A(L) 48VAC/DC G3RV-SL700-D 110VAC G3RV-SL500-D 110VAC G3RV-SL700-A(L) 110VAC G3RV-SL500-A(L) 110VAC G3RV-SL700-D 230VAC G3RV-SL500-D 230VAC G3RV-SL700-A(L) 230VAC G3RV-SL500-A(L) 230VAC Solid State Relays G3RV 1 Specifications ■ Ratings (at an Ambient Temperature of 25°C) Input G3RV-SL700/500-A Series Rated voltage Rated current AC 50 Hz DC Must operate voltage Must release voltage Input voltage % of rated voltage 60 Hz 12 VDC --- --- 15 mA 10.8V 24 VDC --- --- 12 mA 21.6V 24 VAC/DC 20 mA 21 mA 11 mA 21.6V 48 VAC/DC 10 mA 11 mA 6 mA 43.2V 110 VAC 7.5 mA 8.2 mA --- 99V 230 VAC 7.3 mA 8.6 mA --- 207V ±10% 1V G3RV-SL700/500-AL Series Rated voltage Rated current AC 50 Hz DC Must operate voltage Must release voltage Input voltage % of rated voltage 60 Hz 12 VDC --- --- 15 mA 10.8V 24 VDC --- --- 12 mA 21.6V 24 VAC/DC 20 mA 21 mA 11 mA 21.6V 48 VAC/DC 10 mA 11 mA 6 mA 43.2V 110 VAC 7.5 mA 8.2 mA --- 99V 230 VAC 7.3 mA 8.6 mA --- 207V ±10% 1V G3RV-SL700/500-D Series Rated voltage Rated current AC 50 Hz DC Must operate voltage Must release voltage Input voltage % of rated voltage 60 Hz 12 VDC --- --- 8 mA 10.8V 24 VDC --- --- 4.5 mA 21.6V 24 VAC/DC 10.7 mA 11.1 mA 4.3 mA 21.6V 48 VAC/DC 9.6 mA 10.2 mA 6 mA 43.2V 110 VAC 6.8 mA 7.5 mA --- 99V 230 VAC 6.8 mA 8.1 mA --- 207V ±10% 1V Output Item G3RV-SL700/500-A(L) G3RV-SL700/500-D Rated load voltage AC100~240V (50/60Hz) DC5~24V Load voltage range AC75~264V (50/60Hz) DC3~26.4V Load current 0.1~2A (Ta=40°C) 100µA~3A (Ta=40°C) Inrush current 30A (60Hz/1cycle) 30A (60Hz/1cycle) Permissible I2t ; Joule Integral (Reference value) 15A2s 9A2s Application load capacity 400W (Output voltage: AC200V) 72W (Output voltage: DC24V) 2 Solid State Relays G3RV ■ Characteristics G3RV-SL700/500-A G3RV-SL700/500-AL G3RV-SL700/500-D Operate time Item 1/2 of load power source cycle + 1 ms max. 1 ms max. 6 ms max. Release time 40 ms max. 20 ms max. 60 ms max. Output ON voltage drop Leakage current 1.6 V rms max. 0.9 V max. 5 mA max. (at 200 VAC 50/60Hz) 10 µA max. (at 24VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength AC2500V 50/60 Hz for 1 min between input and output Vibration resistance Malfunction: 10 to 55 to 10 Hz, 0.7-mm single amplitude Shock resistance 300m/s2 Ambient temperature Storage: -30~+100°C (with no icing or condensation) Operating: -30~+55°C (with no icing or condensation) Ambient humidity 45~85%RH Weight Approx. 38 g Pollution degree 2 Degree of protection according to IEC 60529 IP20 Rated Impulse Withstand Voltage 4.0kV / III Load category LC-A DC-12 Overload Current Profile 1.5Ie 1.1Ue 5s ON, 10s OFF, 10cycles Rated insulation Voltage 240V ■ Approved Standards UL 508 (File No. E64562) Model Input ratings Contact ratings G3RV-SL700/500-D Series 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC 24 VDC 3 A (Resistive Load) at 25°C G3RV-SL700/500-A(L) Series 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC 240 VAC 2 A (Resistive Load) at 25°C IEC/TUV (EN 62314) Input ratings Contact ratings 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC 24 VDC 3 A (Resistive Load) 12, 24 VDC 24, 48 VAC/DC 110, 230 VAC 240 VAC 2 A (Resistive Load) Solid State Relays G3RV 3 Engineering Data ■ Load current derating curves G3RV-SL700/500-A(L) Series Mounting Distance 10mm Mounting Distance 0mm G3RV-SL700/500-D Series Mounting Distance 10mm Mounting Distance 0mm ■ One Cycle Surge Current: Non-repetitive Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) The values shown by the solid line are for non-repetitive inrush currents. G3RV-SL700/500-D Series 㪠㫅㫉㫌㫊㪿㩷㪺㫌㫉㫉㪼㫅㫋㩷㩿㪘㪅㩷㪧㪼㪸㫂㪀 G3RV-SL700/500-A(L) Series 㪊㪌 㪊㪇 㪉㪌 㪉㪇 㪈㪌 㪈㪇 㪌 㪇 㪈㪇 4 Solid State Relays G3RV 㪈㪇㪇 㪈㪇㪇㪇 㪜㫅㪼㫉㪾㫀㫑㪼㪻㩷㫋㫀㫄㪼㩷㩿㫄㫊㪀 Accessories ■ PLC Interface (for G2RV-SL700 & G3RV-SL700 series only) List of Models Model number P2RVC-8-O-F Description PLC Output Interface for 8x G2RV-SL700 & G3RV-SL700 series PNP - type Connection Ribbon cable connector 10 Pole, IEC603/1 Specifications Input Rated voltage 30 VAC/VDC max. Current capacity 0.5 A per channel 2.0 A total current, power supply terminal Characteristics Ambient temperature Operating: 0 to 55°C Storage: − 20 to 85°C Overvoltage category III Pollution degree 2 Electrical schematic P2RVC-O-8-F Solid State Relays G3RV 5 ■ SSR for Maintenance (Replacement SSRs) Model Number Legend G3RV-@ @ @ @ 1 2 3 4 1. Output voltage specifications D: DC Output 2: AC Output 2. Rated Current 02: AC Output 2A 03: DC Output 3A 3. Terminals S: Plug-In 4. Zero cross function Blank: with Zero cross function L: without Zero cross function List of Models Isolation Phototriac Movement indication Yes (Green) Rated input voltage (Socket) DC12V Output Zero cross (SSR) function AC Yes DC24V Rated output load* Model Number 2A at 100 G3RV-202S DC12 to 240VAC G3RV-202S DC24 AC/DC24V G3RV-202S DC48 G3RV-SL700/500-A AC110 G3RV-202SL DC12 G3RV-SL700/500-AL DC12 G3RV-202SL DC24 G3RV-SL700/500-AL DC12 AC230V G3RV-SL700/500-A AC230 DC12V No DC24V AC/DC24V G3RV-SL700/500-AL AC/DC24 AC/DC48V G3RV-SL700/500-AL AC/DC48 AC110V G3RV-202SL DC48 G3RV-SL700/500-AL AC110 G3RV-D03SL DC12 G3RV-SL700/500-D DC12 AC230V G3RV-SL700/500-AL AC230 DC DC24V --- 3A at 5 to 24 VDC G3RV-D03SL DC24 AC/DC24V AC/DC48V G3RV-SL700/500-D DC24 G3RV-SL700/500-D AC/DC24 G3RV-D03SL DC48 G3RV-SL700/500-D AC/DC48 AC110V G3RV-SL700/500-D AC110 AC230V G3RV-SL700/500-D AC230 *different by ambient temperature. Please refer to 4 pages of characteristic data “ ■ Load current derating curves” for the details. 6 G3RV-SL700/500-A DC24 G3RV-SL700/500-A AC/DC48 AC110V DC12V G3RV-SL700/500-A DC12 G3RV-SL700/500-A AC/DC24 AC/DC48V Photocoupler Replacement for Solid State Relays G3RV ■ Cross bars Model Number Legend P2RVM -@ @ 1 2 1. Number of Poles 020: 2 poles 030: 3 poles 040: 4 poles 100: 10 poles 200: 20 poles 2. Color R: Red S: Blue B: Black List of Models Model number Poles Quantity Color P2RVM-020@ 2 60 pcs / box (minimum order) P2RVM-030@ 3 P2RVM-040@ 4 P2RVM-100@ 10 60 pcs / box (minimum order) Red (R) 60 pcs / box (minimum order) Blue (S) 20 pcs / box (minimum order) Black (B) P2RVM-200@ 20 20 pcs / box (minimum order) @ select color: R = Red, S = Blue, B = Black Specification Max current (EN60947-7-1 section 8.3.3 / 1991) 32A Max. Voltage 400 VAC Max. Voltage when cutting Cross-bar without using separation plate or end-bracket 250 VAC ■ Plastic Labels for G2RV/G3RV Sockets Model number R99-15 for G2RV Box quantity 5 sheets × 120 labels = 600 labels (minimum order) Color White ■ Labels (Stickers) for G2RV/G3RV Sockets Model number R99-16 for G2RV Box quantity Color 10 sheets × 484 labels = White 4,840 labels (minimum order) Solid State Relays G3RV 7 ■ Separating Plates Model number P2RV-S Quantity 50 plates Description Provides isolation between adjacent relays to achieve 400 V isolation. Dimensions Note: All units are in millimeters unless otherwise indicated. Complete Unit G3RV-SL700 Input circuit 106.7 max. 83 70.9 47.2 6.2 max. 26.1 24 V DC Terminal Arrangement/ 35 Internal Connections 92.7 max. (Top View) Five, M2.5 × 6 88.9 7.1 99.2 12 V DC Terminal Arrangement/ Internal Connections (Top View) 8 Solid State Relays G3RV Other Input Voltage Terminal Arrangement/ Internal Connections (Top View) G3RV-SL500 Input circuit 106.7 max. 82.9 69.8 46 6.2 max. 24.6 24 V DC Terminal Arrangement/ Internal Connections 35 97.4 max. (Top View) 88.9 Other Input Voltage Terminal Arrangement/ Internal Connections (Top View) 7.1 99.2 12 V DC Terminal Arrangement/ Internal Connections (Top View) Solid State Relay G3RV-D03SL G3RV-202S(L) Input circuit G3RV-D03SL G3RV-202S(L)   PD[ PD[ Terminal Arrangement/ Internal Connections (Bottom View)   PD[    Solid State Relays G3RV 9 Installation ■ Tools G3RV-SL700 series: Flat-Blade screwdriver should be used for mounting and / or releasing cables. G3RV-SL500 series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables. Applicable Screwdriver ● Flat-blade, Parallel-tip, 2.5 mm diameter (3.0 mm max.) ● Flat-blade, Parallel-tip 2.5 dia. (3.0 mm max.) ● Flat-blade, Flared-tip Cannot be used. Examples: FACOM AEF.2.5 × 75E VESSEL No. 9900-(-)2.5 × 75 WAGO 210-119 WIHA 260/2.5 × 40 (AEF. 3 × 75E) (No. 9900-(-)3 × 100) (260/3 × 50) *Chamfering the tip of the driver improves insertion when used as an exclusive tool. ■ Applicable Wires Applicable Wire Sizes G3RV-SL700 Series Box clamp technology Wire type Applicable wire size Stripping length Stranded without ferrules 0.5 - 1.5 mm2 7 mm Stranded with ferrules and plastic collar 0.5 - 1.5 mm2 7 mm Stranded with ferrules without plastic collar 0.5 - 1.5 mm2 7 mm 2 7 mm Solid 0.5 - 1.5 mm G3RV-SL500 Series Push-in technology Wire type Applicable wire size Stripping length Stranded without ferrules 2 0.5 - 1.5 mm 12 mm Stranded with ferrules and plastic collar 0.5 - 1.5 mm2 12 mm Stranded with ferrules without plastic collar 2 0.5 - 1.5 mm 12 mm Solid 0.5 - 1.5 mm2 12 mm Tightening torque G3RV-SL700 Series: 0.4Nm 10 Solid State Relays G3RV ■ Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G3RV-SL700 series, 12 mm for a G3RV-SL500 series. G3RV-SL700 7 mm G3RV-SL500 12 mm Fig. 1 Exposed Conductor Length Wiring Procedure for G3RV-SL500 series Screwdriver hole Wire connection hole ● Wiring ● Removing Wire Insert the exposed conductor into the connection hole. Insert the specified screwdriver into the release hole. No other tools are required. Removing wire. Note: In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire. Screwdriver should be removed after fully insertion of the wire. Removing screwdriver. Solid State Relays G3RV 11 Precautions Precautions for Connection • Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. • Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit. • Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks. • If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. • Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly. General Precautions • Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. • Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator. • Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock. • Do not pour water or cleansing agents on the product. Doing so may result in electric shock. • Do not use the socket in locations subject to solvents or alkaline chemicals. • Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration. • Do not dispose the product in fire. Removing from Mounting Rail To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below. • Insert the screwdriver along the hole wall as shown below. Screwdriver 12 Solid State Relays G3RV Definition of Precautionary Information WARNING CAUTION Indicates a potentially hazardous situation which, if not avoided, will result in minor or moderate injury, or may result in serious injury or death. Additionally there may be significant property damage. A potentially hazardous situation by misuse, may result in property damage only accident. ● Handling • Be sure to provide adequate air flow to G3RV. Failure to do so can cause the G3RV to overheat leading to short circuit and burning. • Do not install G3RV Relay with bent terminals into the socket. Doing so could lead to poor electrical connection and hazardous conditions. • Be sure to mount G3RV's with clean hands. Performing mounting with oil stained hands or coated with metal powder could result in hazardous outcomes. ● Mounting CAUTION Minor hazard by electric shock may occasionally occur. Do not touch the G3RV's terminal (Charging part) while the power supply turned on. The G3RV may occasionally rupture in case of a short circuit. To protect against short-circuit accident, install a protective device, such as a quick-burning fuse or a circuit breaker or the like, on the power supply. Minor hazard by electric shock may occasionally occur. Do not touch the G3RV's main circuit terminals immediately after the power is turned OFF. The internal snubber circuit is charged. * 202S,SL,G3RV-A(L) Type only Minor hazard by burns may occasionally occur. Do not touch the G3RV or the heat sink either while the power supply is ON, or immediately after the power is turned OFF. The G3RV and the heat sink will be hot. Precautions for Safe Use ● Shipping When shipping the G3RV, be sure to avoid the following: • Conditions where the G3RV is exposed to water. • High ambient temperatures and humidity. • Be sure to mount the G3RV in the specified orientation. Mounting the G3RV in a different orientation could lead to abnormal heat generation causing output elements to short leading to burning. • G3RV's are SSR's and generate heat. Be sure to control ambient temperature in setting where G3RV is used. If mounted in an enclosed space, install a fan to insure G3RV is properly ventilated. • Be sure that the G3RV clicks into place when mounting it to DIN Track. The G3RV may fall if it is not mounted correctly. ● Wiring • Use a wire an adequate size for current to be applied. Abnormal heating of wire may cause burning. • Do not use any wires with damaged sheaths. These may cause electric shock. • Confirm that wiring to G3RV Socket is not used in pipe or duct for high voltage power supply. Using a wire in pipe or duct connected to high voltage power supply will generate induction causing malfunction or damage. • Be sure to conduct wiring with the power supply turned OFF. Touching the terminals when they are charged may occasionally result in minor electric shock. ● Using • Select a load within the rated range. Inappropriate load may cause misoperation, trouble or burning. • Select the power supply within the rated frequency range. Inappropriate power frequency may cause misoperation, trouble or burning. • Inadequate packaging Failure to avoid these conditions while shipping G3RV will lead to damage, malfunction, or deterioration. ● Operating and Storage Locations Do not use or store the G3RV in the locations listed below. Failure to do so may result in damage, malfunction, or deterioration of performance characteristics. • Locations subject to rain or water drops. • Locations subject to exposure to water, or oil, or chemicals. • Locations subject to high temperatures or high humidity. • Locations subject to ambient temperatures outside the range from -30 to +100 centigrade. Precautions for Correct Use ● G3RV uses electronics parts inside, so that any dropping, vibration, and physical shock beyond the standard level should be prevented. Failure to do so may result in damage, malfunction, or deterioration of performance characteristics. ● Be sure to use tightening torque of 0.4 N·m for screw terminal G3RV. Failure to do so could result in short circuit failure and burning. ● Be sure to use proper voltage/current to G3RV input and output terminals. Failure to do so could result in short circuit failure and burning. • Locations subject to relative humidity outside the range 45% to 85%. • Locations subject to corrosive or flammable gases. • Locations subject to dust (especially iron dust) or salts. • Locations subject to barrier. • Locations subject to static electricity or other forms of noise. • Locations subject to strong electromagnetic fields. • Locations subject to possible exposure to radioactivity. Solid State Relays G3RV 13 ● Mounting Be aware of air flow Duct Duct Ventllation outlet SSR SSR SSR 60mm min. Air inlet * If the air inlet or outlet has a filter, clean the filter regularly to prevent it from clogging and ensuring efficient flow of air. SSR * Do no locate any objects around the air inlet or air outlet, otherwise the objects may obstruct the proper ventilation of the control panel. Vertical direction * A heat exchanger, if used, should be located in front of the G2RVs to ensure the efficiency of the heat exchanger. * Please monitor the ambient temperature of the G3RV's. The rated load current is measured at 25°C ambient temperature. * A G3RV uses semiconductor in the output element. This causes the temperature inside the control panel to increase due to heating resulting from the passage of electrical current through the load. To the restrict heating, attach a fan to the ventilation outlet or air inlet of the control panel to ventilate the panel. This will reduce the ambient temperature of the G3RVs and thus increase reliability. (Generally, each 10°C reduction in temperature will double the expected life.) 30mm min. 80mm min. ● EMI • This is a class A product. In residential areas it may cause radio interference, in which case the user may be required to take adequate measures to reduce interference. Suitability for Use OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the product. Duct Depth Counter measure(1) The recommended width is 1/2 as large as the depth of SSR or less Duct or air flow obstruction Vertical direction Know and observe all prohibitions of use applicable to this product. Duct or air flow obstruction Duct or air flow obstruction The depth of SSR Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Counter measure(2) Air flow Metal base SSR SSR NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. SSR See also Product catalog for Warranty and Limitation of Liability. Duct or air flow obstruction Do not surrounded the SSR with the duct in the depth direction, or otherwise the heat radiation of the S5R will be adversely affected. Duct or air flow obstruction Use a short duct in the depth direction. Duct or air flow obstruction If the height of the ducts can not be lowered, place the SSR or a metal base so that they are not surrounded by the ducts. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J180-E2-02 14 In the interest of product improvement, specifications are subject to change without notice. Solid State Relays G3RV
G3RV-SL700-ADC24 价格&库存

很抱歉,暂时无法提供与“G3RV-SL700-ADC24”相匹配的价格&库存,您可以联系我们找货

免费人工找货