0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
Y92A-Y1

Y92A-Y1

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    RING TIME SETTING FOR H2C-S/-SR

  • 数据手册
  • 价格&库存
Y92A-Y1 数据手册
Motor Timer H2C Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 12), and Safety Precautions (page 10). DIN-sized (48 x 48, 45 x 75 mm) Motor Timer with Variable Time Ranges • Five time ranges are selectable per timer unit. • Easy-to-monitor neon lamp for timing operation indication (for 110, 120, 220, 240 VAC types only). • Easy-to-set large transparent knob and easy-to-read single pattern scale facilitate time setting. • Equipped with timing operation indicator and moving pointer. • Conforms to EN61812-1 and IEC60664-1 4 kV/1 for Low Voltage, and EMC Directives (except for H2C-F@). Model Number Structure ■ Model Number Legend H2C-@ @ 1 2 1. External Connection/Attachment None: 11-pin socket S: 11-pin socket/time setting ring 8: 8-pin socket F: Front screw 2. Operation/Resetting System None: Time-limit operation/self-resetting R: Time-limit operation/electric resetting Ordering Information ■ List of Models Operation/resetting system Time-limit operation/ self-resetting Internal connection Terminal Parallel motor and 8-pin socket clutch connection Time-limit contact SPDT Instantaneous contact SPDT 11-pin socket Separate motor and clutch connection 8-pin socket 11-pin socket --- Model H2C-8 H2C Y92A-Y1 Time Set- H2C-S ting Ring Front screw Time-limit operation/ electric resetting Attachment --SPDT --- H2C-F --- H2C-8R SPDT H2C-R Y92A-Y1 Time Set- H2C-SR ting Ring Front screw --- H2C-FR Note: Specify both the supply voltage and time range code (A, B, or C) in addition to the model number when ordering. Example: H2C-S 24 VAC B Time range code Supply voltage Motor Timer H2C 1 ■ Accessories (Order Separately) Name/specifications Models Flush Mounting Adapter Y92F-30 Time Setting Ring (See note 1.) Y92A-Y1 50 cm (l) ´ 7.3 mm (t) Mounting Track PFP-50N 1 m (l) ´ 7.3 mm (t) PFP-100N 1 m (l) ´ 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Protective Cover Y92A-48B Track Mounting/Front Connecting Socket Back Connecting Socket Hold-down Clip (See note 3.) 8-pin P2CF-08 8-pin, finger safe type P2CF-08-E 11-pin P2CF-11 11-pin, finger safe type P2CF-11-E 8-pin, screw terminal P3G-08 8-pin, finger safe type P3G-08 with Y92A-48G (See note 2.) 11-pin P3GA-11 11-pin, finger safe type P3GA-11 with Y92A-48G (See note 2.) For PL08 and PL11 Sockets Y92H-1 For PF085A Socket Y92H-2 Note: 1. Supplied with H2C-S/-SR models. 2. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket. 3. Hold-down Clips are sold in sets of two. Specifications ■ Time Ranges Five time ranges are available for each timer by turning the time range selector every 60 degrees. Note: Rated time is displayed on the window. Time range code Position of time range selector A 1.25 to 30 s 7.5 s to 3 min 1.25 to 30 min 7.5 min to 3 h 1.25 to 30 h B 0.2 to 6 s 2 to 60 s 0.2 to 6 min 2 to 60 min 0.2 to 6 h C 0.5 to 12 s 5 to 120 s 0.5 to 12 min 5 to 120 min 0.5 to 12 h ■ Ratings Item H2C Rated supply voltage (motor and clutch) 24, 48, 100, 110, 115, 120, 200, 220, or 240 VAC (50/60 Hz) (see note) Operating voltage range 85% to 110% of rated supply voltage Power consumption 4.2 VA max. (3.96 W max.) Reset voltage 10% max. of rated supply voltage Reset time Minimum power-opening time: 0.5 s Minimum pulse width: 0.5 s Control outputs 6 A at 250 VAC, resistive load (cosφ = 1) Mounting method Flush mounting (except for H2C-F/-FR models), surface mounting, DIN track mounting Note: The front panel of the timer is color coded to identify the following supply voltage classifications: 100 to 120 V: Blue 200 to 240 V: Red Other classes: Black 2 Motor Timer H2C ■ Characteristics Accuracy of operating time ±0.5% FS max. á±1% max. at 0.2 to 6 s for the time range code B or at 0.5 to 12 s for the time range code C) Setting error ±2% FS max. Reset time 0.5 s max. Influence of voltage ±1% FS max. Influence of temperature ±2% FS max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts) 2,000 VAC, 50/60 Hz for 1 min (between contact and control circuit and between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: Malfunction: 10 to 55 Hz with 0.375-mm single amplitude for 1 h each in three directions 10 to 55 Hz with 0.25-mm single amplitude for 10 min each in three directions Shock resistance Destruction: Malfunction: 1,000 m/s2 150 m/s2 Ambient temperature Operating: Storage: –10°C to 50°C –25°C to 65°C Ambient humidity Operating: 45% to 85% Life expectancy Mechanical: Electrical: 10,000,000 operations min. (under no load at 1,800 operations/h) 500,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h) See Life-test Curve for other details. Motor life expectancy 20,000 h Approved standards UL917, CSA C22.2 No.14. Conforms to EN61812-1 and IEC60664-1 4 kV/1 (except for H2C-F@ models). Output category according to EN60947-5-1 (except for H2C-F@ models). EMC (except for H2C-F@ models) (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: Case color Light gray (Munsell 5Y7/1) Degree of protection IP40 (panel surface) Weight H2C series: approx. 180 g H2C-F series: approx. 270 g EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) 300 200 100 250 VAC cosφ = 1 50 40 30 20 24 VDC cosφ = 1 10 5 1 2 3 4 5 6 Load current (A) Switching operations (x 104) Switching operations (x 104) ■ Life-test Curve 300 200 100 50 40 30 20 250 VAC cosφ = 0.4 24 VDC L/R = 7 msec 10 5 1 2 3 4 5 6 Load current (A) Motor Timer H2C 3 Connections ■ Terminal Arrangement Note: The connections diagrams are for when the clutch is in the excited, reset state. H2C-8 H2C-8R H2C(-F)/H2C-S H2C-(F)R/H2C-SR Clutch coil 6 5 (B1)(B2) Clutch coil (B2) (16) 7 (B1) 8 (18) 4 (16) (24) (22) (A1) (18)(A2) 3 (21) (24) 9 (15) (A1) (A2) 10 2 (15) (21) (22) 1 11 (DIN 46 199-5) 4 Motor Timer H2C 6 (B2) 7 (B1) 8 4 (16) (22) (18) (24) 9 3 (A1) (A2) 2 (15) (21) 10 5 1 11 (DIN 46 199-5) Operation ■ Timing Chart H2C-8 H2C-8R Rt t t Rt Rt Power failure time (t') Rt t Rt Power and motor (2-7) Power (2-7) Time-limit contacts NC (8-5) Time-limit contacts NO (8-6) Instantaneous contacts NC (1-4) Instantaneous contacts NO (1-3) Timing operation indicator lamp (OFF at time-up) t+t' Power and clutch (1-4) Time-limit contacts NC (8-5) Time-limit contacts NO (8-6) Timing operation indicator lamp (OFF at time-up) Rt: Resetting time H2C(-F)/H2C-S t Rt Rt: Resetting time H2C-(F)R/H2C-SR t Power and motor 2(A1)-10(A2) Rt Power and clutch 7(B1)-6(B2) Time-limit contacts NC 1(15)-4(16) Power and motor 2(A1)-10(A2) Power and clutch 7(B1)-6(B2) Time-limit contacts NC 1(15)-4(16) Time-limit contacts NO 1(15)-3(18) Time-limit contacts NO 1(15)-3(18) Instantaneous contacts NC 11(21)-8(22) Instantaneous contacts NC 11(21)-8(22) Instantaneous contacts NO 11(21)-9(24) Instantaneous contacts NO 11(21)-9(24) Timing operation indicator lamp (OFF at time-up) (See note.) Timing operation indicator lamp (OFF at time-up) (See note.) Rt: Resetting time Rt t Rt Power failure time (t') Rt t+t' Rt: Resetting time Note: For the types rated at 24 and 48 VAC, the timing operation indicator is not equipped. Nomenclature Timing operation indicator Time range selector Rated voltage color code Motor Timer H2C 5 Dimensions Note: All units are in millimeters unless otherwise indicated. H2C/H2C-S/H2C-R/H2C-SR/H2C-8/H2C-8R For Flush Mounting 44.8 x 44.8 37 dia. 45+0.6 −0 45+0.6 −0 For a load current of 3 A max., dimension L becomes 3 mm min. with an interval of 0 mm between timers. For a load current of 6 A max., dimension L becomes 8 mm min. with an interval of 5 mm between timers. When using in locations with high ambient temperatures, ensure that there is an interval of at least 5 mm between timers. Mounting Holes H2C-F/H2C-FR Two, M4 or 4.5 dia. holes For a load current of 1 A max., dimension L becomes 10 mm min. with an interval of 0 mm between timers. For a load current of 3 A max., dimension L becomes 15 mm min. with an interval of 5 mm between timers. For a load current of 6 A max., dimension L becomes 20 mm min. with an interval of 10 mm between timers. Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@ Dimensions with Back Connecting Socket P3G-08/P3GA-11 16.3 100.8* H2C H2C-S H2C-R H2C-SR 103.1* H2C-8 H2C-8R 81.5 80 H2C H2C-S H2C-R H2C-SR + Adapter Y92F-30 P2CF-11 P2CF-11-E P2CF-08 P2CF-08-E *These dimensions vary with the kind of DIN track (reference value). 6 Motor Timer H2C P3GA-11 (When Y92A-48G mounted) 16.3 92.2 85.7 H2C-8 H2C-8R + Adapter Y92F-30 P3G-08 (When Y92A-48G mounted) ■ Accessories (Order Separately) Adapter for Flush Mounting Y92F-30 Track Mounting/Front Connecting Socket P2CF-08 Eight, M3.5 x 7.5 sems 7.8 3 4.5 70 max. 35.4 Two, 4.5 dia. holes Terminal Arrangement/ Internal Connections (Top View) Surface Mounting Holes 4 50 max. Two, 4.5 dia. or two, M4 20.3 max. P2CF-08-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eight, M3.5 x 7.5 sems 40±0.2 5 7.8 4.5 3 1.3 70 max. 35.4 Two, 4.5 dia. holes 4 40±0.2 50 max. 19 20.3 21.5 max. Motor Timer H2C 7 Track Mounting/Front Connecting Socket P2CF-11 Eleven, M3.5 x 7.5 sems 3 4.5 7.8 70 max. Terminal Arrangement/ Internal Connections (Top View) 35.4 Two, 4.5 dia. holes Surface Mounting Holes Two, 4.5 dia. or two, M4 4 50 max. 31.2 max. 40±0.2 P2CF-11-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eleven, M3.5 x 7.5 sems 7.8 5 4.5 3 1.2 35.4 70 max. Two, 4.5 dia. holes 4 40±0.2 50 max. 30 31.2 max. Back Connecting Socket P3G-08 Terminal Arrangement/ Internal Connections (Bottom View) 27 dia. 45 45 4.9 17 P3GA-11 Terminal Arrangement/ Internal Connections (Bottom View) 27 dia. 45 25.6 45 4.5 6.2 16.3 Finger Safe Terminal Cover Conforming to VDE0106/P100 Y92A-48G (Attachment for P3G-08/ P3GA-11 Socket) Twelve, 6.4 dia. holes 34 47.7 x 47.7 16.5 47.4 8 Motor Timer H2C 24.6 27.6 48 x 48 Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 15 25 25 10 25 25 10 1,000 (500) (see note) 35±0.3 27 27±0.15 35±0.3 15 15 (5) (see note) 1 25 25 10 25 1,000 25 15 10 24 29.2 1 1.5 Note: The value shown in parentheses are for the PFP-50N. End Plate Spacer PFP-M PFP-S 10 6.2 1 50 1.8 35.5 35.3 10 M4 x 8 pan head screw 34.8 44.3 1.8 11.5 16 12 5 1.3 4.8 16.5 Time Setting Ring Protective Cover Y92A-Y1 Y92A-48B The time setting ring locks the time setting knob to store the set time to facilitate its resetting. A maximum of two time setting rings are connectable per timer. The protective cover shields the front panel, particularly the time setting section, from dust, dirt, and water, as well as prevents the set value from being altered due to accidental contact with the time setting knob. Timer Hold-down Clips Y92H-2 (for PF085A/PF113A Connecting Socket) Y92H-1 (for PL08/PL11 Connecting Socket) Motor Timer H2C 9 Safety Precautions ■ Precautions for Correct Use !CAUTION This may occasionally cause electric shock, fire, or malfunction. Never disassemble, repair, or modify the H2C. How to Change the Time Range This may occasionally cause electric shock, fire, or malfunction. Do not allow metal fragments or lead wire scraps to fall inside the H2C. Change the time range by turning the knob clockwise using a flatblade screwdriver or an Allen wrench. There are five possible settings. The selected time is displayed in the time range display window above the knob. ■ Precautions for Safe Use Observe the following items to ensure the safe use of this product. Time range display window Environmental Precautions • Store the H2C within the specified ratings. If the H2C has been stored at temperatures –10°C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. • Use the H2C within the specified ratings for operating temperature and humidity. • Do not operate the H2C in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. • Do not use the H2C in locations subject to vibrations or shock. Extended use in such locations may result in damage due to stress. • Do not use the H2C in locations subject to excessive dust, corrosive gas, or direct sunlight. • Install the H2C well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. • The H2C is not waterproof or oil resistant. Do not use it in locations subject to water or oil. • The life expectancy of internal components may be reduced if the H2C is mounted side-by-side. • Do not use organic solvents (such as paint thinner or benzine), strong alkaline, or strong acids because they will damage the external finish. Usage Precautions • Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. • Be sure to wire the terminals correctly. • Do not install input lines in the same duct or conduit as power supply or other high-voltage lines. Doing so may result in malfunction due to noise. Separate the input lines from highvoltage lines. • Internal elements may be destroyed if a voltage outside the rated voltage is applied. • Maintain voltage fluctuations in the power supply within the specified range. • Use a switch, relay, or other contact so that the rated power supply voltage will be reached within 0.1 s. If the power supply voltage is not reached quickly enough, the H2C may malfunction or outputs may be unstable. • Leaving the H2C with outputs ON at a high temperature for a long time may hasten the degradation of internal parts (such as electrolytic capacitors). Therefore, use the H2C in combination with relays and avoid leaving the H2C for more than 1 month with an output turned ON. X2/b T 10 T/a X1/a X1 Motor Timer H2C Hex. hole for Allen wrench Do not change the time range while the timer is in operation. How to Select Power Frequency Before using the timer, set the frequency selector located at the rear panel to the proper power frequency (50 to 60 Hz). 50 Hz 60 Hz How to Mount the Timer on Mounting Track Mounting First hook portion A of the timer to the mounting track, then press the timer in direction B. Dismounting Pull out portion C with a round-blade screwdriver and remove the timer from the mounting track. A C B Electrical Set The motor and clutch do not need to be reset simultaneously. X1/a X2 Groove for flatblade screwdriver X Auxiliary relay (e.g., MY Relay) Use the voltage applied to the clutch for resetting with the H2C-@R. Do not allow power to be continuously applied to the motor and clutch for extended periods of time. Others Do not turn the operation time setting knob beyond the range of the scale. To achieve higher accuracy in setting, measure the operation time while turning the operation time setting knob. The deviation and setting error for the operation time shows the percent of FS. The absolute value of the deviation and setting error will not change even if the set time is changed. The time specifications should therefore be selected to use the operation time as close to FS as possible. At high temperatures, the operation voltage will be 90% or less if voltage is applied continuously after timeout. Be sure to keep the voltage within the allowable voltage fluctuation range. Precautions for EN61812-1 The H2C (except for H2C-F@) as a built-in timer conforms to EN61812-1, provided that the following conditions are satisfied. Handling Before dismounting the H2C from the Socket, make sure that no voltage is imposed on any terminal of the H2C. Applicable Sockets: P2CF-@@, P2CF-@@-E, PF085A, PL@@. Wiring Basic insulation is ensured between the motor circuit, clutch circuit, and control output circuit. (However, the H2C-8 motor circuit and clutch circuit use the same input.) Basic insulation is also ensured between the output circuits of models with instantaneous output. Basic insulation: Overvoltage category III, pollution degree 1 (See note.) Operating parts: Reinforced insulation (double insulation) (with a clearance of 5.5 mm and a creepage distance of 5.5 mm at 240 VAC) Output parts: Basic insulation (with a clearance of 3.0 mm and a creepage distance of 3.0 mm at 240 VAC) Note: Overvoltage category II, pollution degree 1 if the Timer is mounted to the PL11 Socket. Motor Timer H2C 11 Warranty and Application Considerations Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. L007-E1-10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company Industrial Devices and Components Division H.Q. Industrial Control Components Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7119/Fax: (81)75-344-7149 12 Printed in Japan 0804-0.5C (0696) (M)
Y92A-Y1 价格&库存

很抱歉,暂时无法提供与“Y92A-Y1”相匹配的价格&库存,您可以联系我们找货

免费人工找货