0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
R0E000010KCE00

R0E000010KCE00

  • 厂商:

    RENESAS(瑞萨)

  • 封装:

    Development Kit

  • 描述:

    EMULATOR DEBUGGER E1 无原盒包装

  • 数据手册
  • 价格&库存
R0E000010KCE00 数据手册
4 E1 Emulator R0E000010KCE00 E20 Emulator R0E000200KCT00 User’s Manual All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corporation without notice. Please review the latest information published by Renesas Electronics Corporation through various means, including the Renesas Electronics Corporation website (http://www.renesas.com). www.renesas.com Rev.4.01 Mar 2016 Notice 1. Descriptions of circuits, software and other related information in this document are provided only to illustrate the operation of semiconductor products and application examples. You are fully responsible for the incorporation of these circuits, software, and information in the design of your equipment. Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from the use of these circuits, software, or information. 2. Renesas Electronics has used reasonable care in preparing the information included in this document, but Renesas Electronics does not warrant that such information is error free. Renesas Electronics assumes no liability whatsoever for any damages incurred by you resulting from errors in or omissions from the information included herein. 3. Renesas Electronics does not assume any liability for infringement of patents, copyrights, or other intellectual property rights of third parties by or arising from the use of Renesas Electronics products or technical information described in this document. No license, express, implied or otherwise, is granted hereby under any patents, copyrights or other intellectual property rights of Renesas Electronics or others. 4. You should not alter, modify, copy, or otherwise misappropriate any Renesas Electronics product, whether in whole or in part. Renesas Electronics assumes no responsibility for any losses incurred by you or third parties arising from such alteration, modification, copy or otherwise misappropriation of Renesas Electronics product. 5. Renesas Electronics products are classified according to the following two quality grades: “Standard” and “High Quality”. The recommended applications for each Renesas Electronics product depends on the product’s quality grade, as indicated below. “Standard”: Computers; office equipment; communications equipment; test and measurement equipment; audio and visual equipment; home electronic appliances; machine tools; personal electronic equipment; and industrial robots etc. “High Quality”: Transportation equipment (automobiles, trains, ships, etc.); traffic control systems; anti-disaster systems; anticrime systems; and safety equipment etc. Renesas Electronics products are neither intended nor authorized for use in products or systems that may pose a direct threat to human life or bodily injury (artificial life support devices or systems, surgical implantations etc.), or may cause serious property damages (nuclear reactor control systems, military equipment etc.). You must check the quality grade of each Renesas Electronics product before using it in a particular application. You may not use any Renesas Electronics product for any application for which it is not intended. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for which the product is not intended by Renesas Electronics. 6. You should use the Renesas Electronics products described in this document within the range specified by Renesas Electronics, especially with respect to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation characteristics, installation and other product characteristics. Renesas Electronics shall have no liability for malfunctions or damages arising out of the use of Renesas Electronics products beyond such specified ranges. 7. Although Renesas Electronics endeavors to improve the quality and reliability of its products, semiconductor products have specific characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use conditions. Further, Renesas Electronics products are not subject to radiation resistance design. Please be sure to implement safety measures to guard them against the possibility of physical injury, and injury or damage caused by fire in the event of the failure of a Renesas Electronics product, such as safety design for hardware and software including but not limited to redundancy, fire control and malfunction prevention, appropriate treatment for aging degradation or any other appropriate measures. Because the evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or systems manufactured by you. 8. Please contact a Renesas Electronics sales office for details as to environmental matters such as the environmental compatibility of each Renesas Electronics product. Please use Renesas Electronics products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances, including without limitation, the EU RoHS Directive. Renesas Electronics assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations. 9. Renesas Electronics products and technology may not be used for or incorporated into any products or systems whose manufacture, use, or sale is prohibited under any applicable domestic or foreign laws or regulations. You should not use Renesas Electronics products or technology described in this document for any purpose relating to military applications or use by the military, including but not limited to the development of weapons of mass destruction. When exporting the Renesas Electronics products or technology described in this document, you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations. 10. It is the responsibility of the buyer or distributor of Renesas Electronics products, who distributes, disposes of, or otherwise places the product with a third party, to notify such third party in advance of the contents and conditions set forth in this document, Renesas Electronics assumes no responsibility for any losses incurred by you or third parties as a result of unauthorized use of Renesas Electronics products. 11. This document may not be reproduced or duplicated in any form, in whole or in part, without prior written consent of Renesas Electronics. 12. Please contact a Renesas Electronics sales office if you have any questions regarding the information contained in this document or Renesas Electronics products, or if you have any other inquiries. (Note 1) “Renesas Electronics” as used in this document means Renesas Electronics Corporation and also includes its majorityowned subsidiaries. (Note 2) “Renesas Electronics product(s)” means any product developed or manufactured by or for Renesas Electronics. (2012.4) E1/E20 Emulator Preface Preface The E1 emulator (R0E000010KCE00) and the E20 emulator (R0E000200KCT00) are designed for use with the MCU’s made by Renesas Electronics. All components of the E1 and E20 emulators are listed under “1.1 Package Components”. If you have any questions about the E1 or E20 emulator, contact your local distributor. Documentation for the E1/E20 emulator manual is in two parts: the E1/E20 Emulator User’s Manual (this manual) and the E1/E20 Emulator Additional Document for the User’s Manual. Different versions of the latter correspond to different sets of MCUs. This user’s manual describes mainly the hardware specifications of the E1 and E20 emulators. For information on emulator debuggers and other related products, please see the additional document for user’s manuals included with each product. You can download the latest manuals from the Renesas Tools homepage. [E1] http://www.renesas.com/e1 [E20] http://www.renesas.com/e20 R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 3 of 40 E1/E20 Emulator Important Important Before using the emulator, be sure to read this user’s manual carefully. Keep this user’s manual, and refer to it when you have questions about the emulator. Emulator: "Emulator" in this user’s manual collectively refers to the E1 and E20 emulators manufactured by Renesas Electronics Corporation. "Emulator" herein encompasses neither the customer's user system nor the host machine. Purpose of use of the emulator: This emulator is a device to support the development of systems that uses the Renesas microcomputers. It provides support for system development in both software and hardware. By using in combination with a programming software, it is available as a Flash programming tool. Be sure to use the emulator correctly according to said purpose of use. Please avoid using the emulator other than for its intended purpose of use. For those who use the emulator: The emulator can only be used by those who have carefully read the user’s manual and know how to use it. Use of the emulator requires basic knowledge of electric circuits, logical circuits, and MCUs. When using the emulator: (1) The emulator is a development-support unit for use in your program development and evaluation stages. When a program you have finished developing is to be incorporated in a mass-produced product, the judgment as to whether it can be put to practical use is entirely your own responsibility, and should be based on evaluation of the device on which it is installed and other experiments. (2) In no event shall Renesas Electronics Corporation be liable for any consequence arising from the use of the emulator. (3) Renesas Electronics Corporation strives to provide workarounds for and correct trouble with products malfunctions, with some free and some incurring charges. However, this does not necessarily mean that Renesas Electronics Corporation guarantees the provision of a workaround or correction under any circumstances. (4) The emulator covered by this document has been developed on the assumption that it will be used for program development and evaluation in laboratories. Therefore, it does not fall within the scope of applicability of the Electrical Appliance and Material Safety Law and protection against electromagnetic interference when used in Japan. (5) Renesas Electronics Corporation cannot predict all possible situations and possible cases of misuse that carry a potential for danger. Therefore, the warnings in this user's manual and the warning labels attached to the emulator do not necessarily cover all such possible situations and cases. The customer is responsible for correctly and safely using the emulator. (6) This emulator has acquired the standards shown in "1.5 Regulatory Compliance Notices". This fact must be taken into account when the emulator is taken from Japan to some other country. (7) Renesas Electronics Corporation will not assume responsibility of direct or indirect damage caused by an accidental failure or malfunction in the emulator. When disposing of the emulator: Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 4 of 40 E1/E20 Emulator Important Usage restrictions: The emulator has been developed as a means of supporting system development by users. Therefore, do not use it as an embedded device in other equipment. Also, do not use it to develop systems or equipment for use in the following fields. (1) (2) (3) (4) (5) Transportation and vehicular Medical (equipment that has an involvement in human life) Aerospace Nuclear power control Undersea repeaters If you are considering the use of the emulator for one of the above purposes, please be sure to consult your local distributor. About product changes: We are constantly making efforts to improve the design and performance of our product. Therefore, the specification or design of the emulator, or this user's manual, may be changed without prior notice. About rights: (1) We assume no responsibility for any damage or infringement on patent rights or any other rights arising from the use of any information, products or circuits presented in this user’s manual. (2) The information or data in this user’s manual does not implicitly or otherwise grant a license to patent rights or any other rights belonging to Renesas or to a third party. (3) This user’s manual and the emulator are copyrighted, with all rights reserved by Renesas. This user’s manual may not be copied, duplicated or reproduced, in whole or part, without prior written consent from Renesas. About diagrams: Some diagrams in this user’s manual may differ from the objects they represent. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 5 of 40 E1/E20 Emulator Precautions for safety Precautions for Safety This chapter, by showing the relevant diagrammatic symbols and their meanings, describes the precautions which should be taken in order to use this product safely and properly. Be sure to read and understand this chapter before using this product. Contact us if you have any questions about the precautions described here. WARNING WARNING indicates a potentially dangerous situation that will cause death or heavy wound unless it is avoided. CAUTION CAUTION indicates a potentially dangerous situation that will cause a slight injury or a medium-degree injury or property damage unless it is avoided. To avoid a possible danger, the following diagrammatic symbols are used to call your attention. means WARNING or CAUTION. Example: CAUTION AGAINST AN ELECTRIC SHOCK means PROHIBITION. Example: DISASSEMBLY PROHIBITED means A FORCIBLE ACTION. Example: UNPLUG THE POWER CABLE FROM THE RECEPTACLE. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 6 of 40 E1/E20 Emulator Precautions for safety WARNING Warnings for AC Power Supply: Do not repair or remodel the emulator product by yourself in order to prevent danger such as an electric shock or fire and for the sake of quality assurance. For after-sale services in case of a mechanical or electrical fault, please contact your local distributor. Always switch off the host computer and user system before connecting or disconnecting any cables or parts. Neglect of this precaution will result in getting an electric shock or will result in the emulator product or user system emitting smoke or catching fire. Also, the user program under debug will be destroyed. Make sure that the connectors on both ends of the user-system interface cable are facing the right way relative to the user-side connector on the emulator and the connector on the user system, respectively. Neglect of this precaution will result in getting an electric shock or will result in the emulator product or user system emitting smoke or catching fire. Warning for Modification: Do not modify the emulator. Personal injury due to electric shock may occur if the emulator is modified. Modifying the product will void your warranty. Warning for Installation: Do not set the emulator in water or areas of high humidity. Make sure that the product does not get wet. Spilling water or some other liquid into the product may cause un-repairable damage. Warning for Use temperature: The emulator is to be used in an environment with a maximum ambient temperature of 35°C. Care should be taken that this temperature is not exceeded. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 7 of 40 E1/E20 Emulator Precautions for safety CAUTION Cautions to Be Taken for Handling The emulator: Use caution when handling the emulator. Be careful not to apply a mechanical shock. Do not touch the connector pins of the emulator and the target MCU connector pins directly. Static electricity may damage the internal circuits. When attaching and removing the cable, hold the plug of the cable and do not touch the cable. When installing the emulator, do not flex the cable excessively or pull the emulator or the board by the cable connected to it. The cable may cause a break. Do not tape the flexible cable or apply adhesives to secure the cable. The shielding material on the surface of the cable may come off. Caution to Be Taken for System Malfunctions: If the emulator malfunctions because of interference like external noise, do the following to remedy the trouble. (1) Exit the emulator debugger, and shut OFF the emulator and the user system. (2) After a lapse of 10 seconds, turn ON the power of the emulator and the user system again, then launch the emulator debugger. Caution to Be Taken for Disposal: Penalties may be applicable for incorrect disposal of this waste, in accordance with your national legislation. European Union regulatory notices: The WEEE (Waste Electrical and Electronic Equipment) regulations put responsibilities on producers for the collection and recycling or disposal of electrical and electronic waste. Return of WEEE under these regulations is applicable in the European Union only. This equipment (including all accessories) is not intended for household use. After use the equipment cannot be disposed of as household waste, and the WEEE must be treated, recycled and disposed of in an environmentally sound manner. Renesas Electronics Europe GmbH can take back end of life equipment, register for this service at “http://www.renesas.eu/weee” R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 8 of 40 E1/E20 Emulator Contents Contents Page Preface .............................................................................................................................................................. 3 Important ............................................................................................................................................................ 4 Precautions for Safety ....................................................................................................................................... 6 Contents............................................................................................................................................................. 9 Terminology ..................................................................................................................................................... 10 1. Outline .......................................................................................................................................................... 11 1.1. Package Components ........................................................................................................................ 11 1.2. System Configuration ........................................................................................................................ 12 1.3. PC Interface....................................................................................................................................... 12 1.4. Specifications .................................................................................................................................... 13 1.5. Regulatory Compliance Notices ........................................................................................................ 14 1.5.1. European Union regulatory notices......................................................................................... 14 1.5.2. United States Regulatory notices ............................................................................................ 14 1.6. Emulator Hardware Configuration ..................................................................................................... 15 1.7. The Names of the Emulator Parts ..................................................................................................... 16 1.8. Operating Environment ..................................................................................................................... 17 2. Setup ........................................................................................................................................................... 18 2.1. Installing Emulator Software .............................................................................................................. 18 2.2. Connecting the Emulator to the Host Computer ............................................................................... 18 2.3. Connecting the Emulator to the User System ................................................................................... 19 2.4. Turning the Power On/Off .................................................................................................................. 23 2.4.1. When a Separate Power Supply is Used for the User System ............................................... 23 2.4.2. When Power is supplied to the User System from the Emulator (E1 Only)............................ 24 2.5. Connecting System Ground .............................................................................................................. 25 3. Troubleshooting (Action in Case of an Error) .............................................................................................. 26 3.1. How to Solve a Trouble ..................................................................................................................... 26 3.1.1. ACTION LED does not light .................................................................................................... 26 3.1.2. Unconnectable with the debugger .......................................................................................... 26 3.2. How to Request Support ................................................................................................................... 26 4. Maintenance and Warranty.......................................................................................................................... 27 4.1. Maintenance ...................................................................................................................................... 27 4.2. Warranty ............................................................................................................................................ 27 4.3. Repair Provisions .............................................................................................................................. 28 4.4. How to Make Request for Repair ...................................................................................................... 28 Appendix A Self-Checking Program (SCP)...................................................................................................... 29 A.1 Flow of Self-Checking ........................................................................................................................ 29 A.2 Preparations for Self-Checking .......................................................................................................... 30 A.3 Executing the Self-Checking Program ............................................................................................... 31 Revision History ............................................................................................................................................... 37 R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 9 of 40 E1/E20 Emulator Terminology Terminology Some specific words used in this user's manual are defined below. Integrated development environment: High-performance Embedded Workshop This tool provides powerful support for the development of embedded applications for Renesas microcomputers. It has an emulator debugger function allowing the emulator to be controlled from the host machine via an interface. Furthermore, it permits a range of operations from editing a project to building and debugging it to be performed within the same application. In addition, it supports version management. Emulator debugger This means a software tool that is started up from the High-performance Embedded Workshop, and controls the emulator and enables debugging. Programming software This means Flash Development Toolkit or Renesas Flash Programmer that is available on the emulator. Host machine This means a personal computer used to control the emulator. Target MCU This means the MCU to be debugged. User system This means a user's application system in which the MCU to be debugged is used. User program This means the program to be debugged. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 10 of 40 E1/E20 Emulator Outline 1. Outline This chapter describes the package components, the system configuration, and the specifications of the emulator functions and operating environment. 1.1. Package Components The E1/E20 emulator package consists of the following items. After you have unpacked the box, check if your E1 or E20 emulator contains all of these items. Table 1.1 and Table 1.2 show the packing components for the E1 and E20, respectively. Table 1.1 Package components for the E1 Item Main E1 emulator unit (R0E000010KCE00) USB interface cable (A plug — mini-B plug, 1.5 m, high-speed grade) User-system interface cable (14-pin flat cable, 15cm) CD-ROM - Guide to the software information page - Self-Checking Program - E1/E20 Emulator User’s Manual Quantity 1 1 1 1 Table 1.2 Package components for the E20 Item Main E20 emulator unit (R0E000200KCT00) USB interface cable (A plug — mini-B plug, 1.5 m, high-speed grade) User-system interface cable (38-pin flexible cable, 20cm) 38-pin to 14-pin conversion adapter (R0E000200CKA00) CD-ROM - Guide to the software information page - Self-Checking Program - E1/E20 Emulator User’s Manual Quantity 1 1 1 1 1 Please keep the E1/E20 emulator's packing box and cushioning materials at hand for later reuse in sending the product for repairs or for other purposes. Always use the original packing box and cushioning material when transporting the E1 or E20 emulator. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 11 of 40 E1/E20 Emulator Outline 1.2. System Configuration The E1 or E20 emulator is used by connecting it to the target MCU mounted on the user system. Figure 1.1 shows the configuration of the emulator system. User-system interface cable (with the 14-or 38-pin connector) Integrated Development Environment + Emulator debigger User system Host computer USB interface cable E1 or E20 emulator Figure 1.1 System configuration with an Emulator (1) (2) (3) (4) E1 or E20 emulator (this product) USB interface cable (included) User-system interface cable (included) User system This is your application system using the MCU to be debugged. The E20 emulator cannot supply power to the user system. Get a power supply separately. (5) Host machine A personal computer to control the emulator by USB interface. 1.3. PC Interface  USB Interface *1 USB 2.0 high-speed (also connectable to the USB 1.1-compatible host machine) Note: 1 Not guaranteed to operate in any combination of a host machine, USB device, and USB hub. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 12 of 40 E1/E20 Emulator Outline 1.4. Specifications Table 1.3 lists the specifications of the E1 or E20 emulator. Table 1.3 Specifications of the E1 or E20 emulator Item Emulator Type PC Interface User Interface Power Voltage for the emulator Power supply for the target MCU External dimension (main body) Weight Operating temperature Storage temperature EMC Description E1 Emulator E20 Emulator Type name: R0E000010KCE00 Type name: R0E000200KCT00 USB 2.0 (high speed/ full speed) 14-pin connector 38-pin connector 7614-6002 [3M Japan Limited] 2-5767004-2 [Tyco Electronics Japan 2514-6002 [3M Limited] G.K.] USB-bus power supply (VBUS 4.5 V, min / 500 mA, min) Supplied from the user system or Supplied from the E1 emulator (200 mA, max *) 109.4 mm × 53.2 mm × 18.6 mm 72g 5 to 35°C (no condensation) -10 to 60°C (no condensation) EU: EN 55022 Class A, EN 55024 USA: FCC part 15 Class A Note: If you can supply 500mA from USB VBUS R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Supplied from the user system 114.9 mm × 74.2 mm × 19.2 mm 103g Page 13 of 40 E1/E20 Emulator Outline 1.5. Regulatory Compliance Notices 1.5.1. European Union regulatory notices This product complies with the following EU Directives. (These directives are only valid in the European Union.) CE Certifications: ・Electromagnetic Compatibility (EMC) Directive 2014/30/EU EN 55022 Class A WARNING: This is a Class A product. This equipment can cause radio frequency noise when used in the residential area. In such cases, the user/operator of the equipment may be required to take appropriate countermeasures under his responsibility. EN 55024  Information for traceability  Authorised representative Name: Renesas Electronics Corporation Address: Toyosu Foresia, 3-2-24, Toyosu, Koto-ku, Tokyo 135-0061, Japan  Manufacturer Name: Renesas System Design Co., Ltd. Address: 5-20-1, Josuihon-cho, Kodaira-shi, Tokyo 187-8588, Japan  Person responsible for placing on the market Name: Renesas Electronics Europe GmbH Address: Arcadiastrasse 10, 40472 Dusseldorf, Germany  Trademark and Type name Trademark: Renesas Product name: E1 Emulator / E20 Emulator Type name: R0E000010KCE00 / R0E000200KCT00 Environmental Compliance and Certifications:  Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU 1.5.2. United States Regulatory notices This product complies with the following EMC regulation. (This is only valid in the United States.) FCC Certifications: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 14 of 40 E1/E20 Emulator Outline 1.6. Emulator Hardware Configuration As shown in Figures 1.2 and 1.3, the emulator consists of a main emulator unit, a USB interface cable, and a usersystem interface cable. The emulator is connectable to the host computer via a USB port compliant with USB 2.0 (Full-Speed/High-Speed) or USB 1.1. USB interface cable VCC ACT RESET RUN SELF CHECK User-system interface cable E1 main emulator unit Figure 1.2 E1 Hardware Configuration Optional 38-pin to 14-pin conversion adapter included in the package USB interface cable RESET RUN TOP VCC ACT User-system interface cable SELF CHECK E20 main emulator unit Note: The 38-pin to 14-pin conversion adapter is used to connect the E20 to a board on which a 14-pin connector is mounted. Figure 1.3 E20 Hardware Configuration R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 15 of 40 E1/E20 Emulator Outline 1.7. The Names of the Emulator Parts The names of the emulator parts are given in Figures 1.4 to 1.6. E1 Emulator E20 Emulator (c) (e) (e) (c) VCC ACT VCC RESET ACT RESET RUN SELF CHECK (a) Logotype: (b) Connector for self-checking: (c) ACTIVE LED: (d) VCC LED: (e) RESET LED: (f) RUN LED: (b) (d) (a) (d) TOP (a) RUN (f) SELF CHECK (b) (f) The casing bears the “RENESAS E1” or “RENESAS E20” logotype. A connector for use in self-checking. The lid is usually closed because this connector is not used during debugging. For details on the self-checking procedure, refer to appendix A. Marked ‘ACT’. This LED indicates the operating state of the E1 or E20 control software. Illuminated: The emulator is usable. Blinking: The USB driver has not been recognized (e.g. the USB driver has not correctly been installed). Not illuminated: The emulator is not usable for some reason. Marked ‘VCC’. This LED indicates the current state of power supply to the user system. Illuminated (orange): The emulator is supplying power to the user system. Illuminated (yellowish green): External power for the user system is on. Not illuminated: The user system is not being supplied with power. Marked ‘RESET’. This LED indicates whether or not the signal on the MCU RESET pin of the user system is being enabled. Illuminated: The reset signal is enabled. Not illuminated: The reset signal is disabled. Marked ‘RUN’. This LED indicates whether or not the MCU on the user system is running. Illuminated: The user program is running. Not illuminated: A break in execution of the user program Figure 1.4 E1 and E20 Top View R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 16 of 40 E1/E20 Emulator Outline E1 Emulator E20 Emulator (b) (a) (a) (b) (c) I (a) Host-side connector: (b) Host-side connector mark: (c) Power switch (E20 only): O A USB connector for the host computer. Be sure to connect the provided USB interface cable. Marked “ ”. A connector for the host computer is provided at the side of this mark. Power switch of the emulator. When the switch is shifted to “|”, the power is on. Shifting the switch to “”, on the other hand, turns off the power. The USB supplies power to the emulator. Figure 1.5 E1 and E20 Host-Side View E1 Emulator E20 Emulator (b) (a) (b) (a) USER I/F USER I/F (a) User-side connector: (b) User-side connector mark: A user-system interface cable is connected. Marked ‘USER I/F’. A connector for the user-system interface cable is provided at the side of this mark. Figure 1.6 E1 and E20 User-Side View 1.8. Operating Environment Observe the conditions listed in Table 1.4 when using the emulator. Table 1.4 Operating environmental conditions Item Temperature Humidity Vibration Ambient gases R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Description Operating: +5°C to +35°C Storage: –10°C to +60°C 35% RH to 80% RH, no condensation Operating: 2.45 m/s2 max. Storage: 4.9 m/s2 max. Transportation: 14.7 m/s2 max. No corrosive gases may be present Page 17 of 40 E1/E20 Emulator Setup 2. Setup 2.1. Installing Emulator Software Insert the installation media into the host machine. Follow the displayed procedure to download and install the emulator software. 2.2. Connecting the Emulator to the Host Computer Use the USB interface cable to connect the emulator to the host computer as shown in Figure 2.1. For the position of each connector of the emulator, refer to section 1.7, The Names of the Emulator Parts. Host computer USB interface cable(1.5m) E1 or E20 emulator Figure 2.1 System Configuration when Connecting the Emulator to the Host Computer (1) Connect the A plug of the USB interface cable to the USB I/F connector of the host machine. (2) Connect the mini-B plug of the USB interface cable to the USB I/F connector of the E1 or E20 emulator. The USB interface cable included with the product conforms to the USB 2.0 high-speed standard. When you use the E1 or E20 emulator, be sure to use the USB interface cable supplied with it. The E1 emulator is turned on by connecting the USB interface cable. When using the E20 emulator, turn on its power switch. The E20 emulator is turned on when the power switch is shifted to the on position after connecting the USB interface cable. On Windows Vista®, Windows® 7, Windows® 8, Windows® 8.1 and Windows® 10, the USB driver is automatically installed. On Windows® XP, the USB driver is installed first time the emulator is turned on. When “Can Windows connect to Windows Update to search for software?” is displayed, select “No, not this time” and then click on [Next]. When “What do you want the wizard to do?” is displayed, select “Install the software automatically (Recommended)” and then click on [Next]. If the USB port of the host machine or the emulator to be connected is changed, the USB driver is re-installed. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 18 of 40 E1/E20 Emulator Setup 2.3. Connecting the Emulator to the User System Use the procedure below to connect the emulator to the user system with the user-system interface cable, or to disconnect them when moving the emulator or the user system. (1) Connect the user-system interface cable to the user-side connector of the emulator. When connecting the user-system interface cable to the E1 emulator, check the position of the erroneous insertion prevention key to ensure that the cable is plugged in correctly. When connecting the user-system interface cable to the E20 emulator, check to see that the cable is plugged in correctly, with the TOP side of its connector cover up. User-side connector User-side connector USER I/F USER I/F E1 Emulator E20 Emulator Figure 2.2 User-Side Connector on the E1 and E20 CAUTION Notes on connector insertion and removal: When connecting or disconnecting the user-system interface cable and the emulator or user system, grasp the connector cover at the end of the cable. Pulling the cable itself will damage the wiring. Also, be aware that the user-system interface cable has the direction in which it must be inserted. If the cable is connected in the wrong direction, it may break down. Correct example R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Incorrect example Page 19 of 40 E1/E20 Emulator Setup (2) A connector to the user-system interface cable must be installed on the user system. Table 2.1 shows the recommended connector for the emulator. Table 2.1 Recommended Connector Connector 14-pin connector 38-pin connector Type Number 7614-6002 2514-6002 2-5767004-2 Manufacturer 3M Japan Limited 3M Limited Tyco Electronics Japan G.K. Specifications 14-pin straight type (Japan) 14-pin straight type (other countries) 38-pin type (3) For the pin assignments of the connector, refer to the separate MCU-specific manual for the emulator. (4) Connect one end of the user-system interface cable to the emulator and the other end to the connector on the user system as shown in Figures 2.3, 2.4, and 2.5. 14-pin user-system interface cable 14-pin connector 7614-6002 or 2514-6002 Pin 2 User system Pin 1 Figure 2.3 Connecting the User-System Interface Cable to the User System when the 14-Pin Connector is in Use with the E1 CAUTION Notes on connector insertion and removal: When connecting or disconnecting the user-system interface cable and the emulator or user system, grasp the connector cover at the end of the cable. Pulling the cable itself will damage the wiring. Correct example R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Incorrect example Page 20 of 40 E1/E20 Emulator Setup 38-pin user-system interface cable 9.4 mm 38-pin to 14-pin conversion adapter 14-pin connector 7614-6002 or 2514-6002 10 mm 9.4 mm 26.2 mm 38-pin to 14-pin conversion adapter (top view) R0E000200CKA00 (include in the E20 package) User system Figure 2.4 Connecting the User-System Interface Cable to the User System when the 14-Pin Connector is in Use with the E20 CAUTION Limit to the height on connector periphery: For a case where the R0E000200CKA00 is used for connecting the E20 emulator to a 14-pin connector: When designing the layout of a user board with a 14-pin connector, do not mount other components with a height of 10 mm or more within 5 mm of the connector on the user system. 3M Japan Ltd.) R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 21 of 40 E1/E20 Emulator Setup 38-pin user-system interface cable 30 mm 1 38 2 15 mm 37 38-pin connector 2-5767004-2 5 mm : Area with limit on mounted components User system Figure 2.5 Connector (top view) Connecting the User-System Interface Cable to the User System when the 38-Pin Connector is in Use with the E20 CAUTION Limit to the height on connector periphery: For a case where the E20 emulator is connected to a 38-pin connector: When designing the layout of a user board with a 38-pin connector, reduce cross-talk noise etc. by keeping other signal lines out of the region where the connector is situated. As shown in Figure 2.5, an upper limit (5 mm) applies to the heights of components mounted around the connector on the user system (indicated by “area with limit on mounted components” in the figure). R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 22 of 40 E1/E20 Emulator Setup 2.4. Turning the Power On/Off Turn the power of the E1 or E20 emulator and the user system following the procedure below. 2.4.1. When a Separate Power Supply is Used for the User System (1) Check the power is off. Check that the user system is turned off. When using the E20 emulator, check its power switch is off. (2) Connect the user system. Connect the emulator and the user system with a user-system interface cable. (3) Connect the host machine and turn on the emulator. Connect the emulator and the host machine with a USB interface cable. The E1 emulator is turned on by connecting the USB interface cable. When using the E20 emulator, turn on its power switch. (4) Launch the emulator debugger or programming software. Launch the emulator debugger or programming software. (5) Turn on the user system Turn on the user system. (6) Connect the emulator debugger or programming software to the emulator. Connections may vary depending on software. (1) Disconnect the emulator debugger or programming software from the emulator. Disconnections may vary depending on software. (2) Turn off the user system. Turn off the user system. (3) Close the emulator debugger or programming software. Close the emulator debugger or programming software. (4) Turn off the emulator and disconnect the emulator. When using the E20 emulator, turn off its power switch. Disconnect the USB interface cable from the E1 or E20 emulator. The E1 emulator is turned off by disconnecting from the USB interface cable. (5) Disconnecting the user system Disconnect the user-system interface cable from the user system. CAUTION Note on the User System Power Supply : While the power of the user system is on, do not turn off the host machine, unplug the USB interface cable, or turn off the power switch of the E20 emulator. The user system may be damaged due to leakages current. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 23 of 40 E1/E20 Emulator Setup 2.4.2. When Power is supplied to the User System from the Emulator (E1 Only) (1) Connect the user system. Connect the emulator and the user system with a user-system interface cable. (2) Connect the host machine and turn on the emulator. Connect the emulator and the host machine with a USB interface cable, then turn on the emulator. (3) Launch the emulator debugger or programming software. Launch the emulator debugger and select the setting of power supply to the user system. (4) Connect the emulator debugger or programming software to the emulator. Connections may vary depending on software. (1) Disconnect the emulator debugger or programming software from the emulator. Disconnections may vary depending on software. (2) Close the emulator debugger or programming software. Close the emulator debugger or programming software. (3) Turn off the emulator and disconnect the emulator. Disconnect the USB interface cable from the emulator, then turn off the emulator. (4) Disconnecting the user system Disconnect the user-system interface cable from the user system. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 24 of 40 E1/E20 Emulator Setup 2.5. Connecting System Ground The emulator's signal ground is connected to the user system's signal ground. In the emulator, the signal ground and frame ground are connected. In the user system, connect the frame ground only; do not connect the signal ground to the frame ground (Figure 2.6). If it is difficult to separate the frame ground from the signal ground in the user system, set the GND for DC power input (AC adapter) of the host computer and the frame ground of the user system as the same potential. If the GND potential is different between the host computer and the user system, an overcurrent will flow in the lowimpedance GND line and thin lines might be burned. WARNING Connecting System Ground : Separate the frame ground from the signal ground at the user system. Failure to do so will result in smoke, fire, or an electric shock due to the difference in ground potential. Signal ground E1/E20 emulator Signal Signal Logic Logic Host computer User system USB Signal ground Signal ground Power supply Frame ground Figure 2.6 Connecting System Ground For a debugging environment where there is a GND gap between the user system and host PC, use the isolator for the E1 emulator (R0E000010ACB10 / R0E000010ACB20) or the isolator for the E20 emulator (R0E000200ACB10) that are separately available from Renesas. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 25 of 40 E1/E20 Emulator Troubleshooting (Action in Case of an Error) 3. Troubleshooting (Action in Case of an Error) 3.1. How to Solve a Trouble The following describes how to solve a trouble when any problem occurs before the emulator debugger starts after the emulator and the user system have been powered on. For the latest information on the emulator and emulator debugger, visit Renesas Electronics’ development environment website (http://www.renesas.com/tools). 3.1.1. ACTION LED does not light (1) Keeps flashing The USB driver is not installed correctly in the host machine. Install the USB driver correctly. (2) Remains off This means that the E1 or E20 is in an unusable state for some reason. Check the following: • Whether the E1 or E20 and the host machine are connected with the USB interface cable. • Whether the power switch of the E20 is turned on. • Whether the power for the host machine is turned on. 3.1.2. Unconnectable with the debugger (1) Check the connection between the emulator and the MCU. For details, consult the separate E1/E20 manual for the MCU you’re using. • Whether the emulator and the MCU are connected correctly. • Whether the connected signal lines are pulled up to the power supply or down to GND properly. (2) Check to see that the MCU is in a ready state. • The MCU operating clock is on (= oscillating). • The MCU is supplied with power properly. • The MCU has been reset and is ready to go. 3.2. How to Request Support After checking the items in “Troubleshooting”, contact us from the following URL. http://www.renesas.com/contact/ For prompt response, please specify the following information: (1) Operating environment MCU name: Operating frequency: [MHz] MCU operating mode: [Mode] (2) Condition The emulator debugger starts up / does not start up The error is detected / not detected in the self-check Frequency of errors: always / frequency ( ) (3) Problem R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 26 of 40 E1/E20 Emulator Maintenance and Warranty 4. Maintenance and Warranty This chapter covers basic maintenance, warranty information, provisions for repair and the procedures for requesting a repair. 4.1. Maintenance (1) If dust or dirt collects on this product, wipe it off with a dry soft cloth. Do not use thinner or other solvents because these chemicals can cause the surface coating to separate. (2) When you do not use this product for a long period, disconnect it from the power supply, host machine and user system. 4.2. Warranty (1) This product comes with a one-year limited warranty after purchase. Should the product break down or be damaged while you’re using it under normal condition based on its user’s manual, it will be repaired or replaced free of cost. (2) However, if the following failure or damage occurs to the product under warranty, the product will be repaired or replaced at cost. a) Failure or damage attributable to the misuse or abuse of the product or its use under other abnormal conditions. b) Failure or damage attributable to improper handling of the product after purchase, such as dropping of the product when it is transported or moved. c) Failure or damage to the product caused by other pieces of equipment connected to it. d) Failure or damage attributable to fire, earthquakes, thunderbolts, floods, or other natural disasters or abnormal voltages, etc. e) Failure or damage attributable to modifications, repairs, adjustments, or other acts made to the product by other than Renesas Electronics Corporation. (3) Consumables (e.g., sockets and adapters) are not covered by the aforementioned repair. In the above cases, contact your local distributor. If your product is being leased, consult the leasing company or the owner. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 27 of 40 E1/E20 Emulator Maintenance and Warranty 4.3. Repair Provisions (1) Repairs not covered by warranty Problems arising in products for which more than one year has elapsed since purchase are not covered by warranty. (2) Replacement not covered by warranty If your product's fault falls into any of the following categories, the fault will be corrected by replacing the entire product instead of repairing it, or you will be advised to purchase a new product, depending on the severity of the fault. - Faulty or broken mechanical portions - Flaws, separation, or rust in coated or plated portions - Flaws or cracks in plastic portions - Faults or breakage caused by improper use or unauthorized repair or modification - Heavily damaged electric circuits due to overvoltage, overcurrent or shorting of power supply - Cracks in the printed circuit board or burnt-down patterns - A wide range of faults that make replacement less expensive than repair - Faults that are not locatable or identifiable (3) Expiration of the repair period When a period of one year has elapsed after production of a given model ceased, repairing products of that model may become impossible. (4) Carriage fees for sending your product to be repaired Carriage fees for sending your product to us for repair are at your own expense. 4.4. How to Make Request for Repair If your product is found faulty, fill in a Repair Request Sheet downloadable from the following URL. And email the sheet and send the product to your local distributor. http://www.renesas.com/repair CAUTION Note on Transporting the Product: When sending your product for repair, use the packing box and cushioning material supplied with the product when it was delivered to you and specify caution in handling (handling as precision equipment). If packing of your product is not complete, it may be damaged during transportation. When you pack your product in a bag, make sure to use the conductive plastic bag supplied with the product (usually a blue bag). If you use a different bag, it may lead to further trouble with your product due to static electricity. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 28 of 40 E1/E20 Emulator Appendix A Appendix A Self-Checking Program (SCP) This section gives the procedure for using the self-checking program for the E1 and E20 in fault analysis. A.1 Flow of Self-Checking Install the emulator software.  Connect the user interface cable.  Connect the USB interface cable*.  Initiate the SCP for the E1 and E20.  Execute the TEST1 and TEST2 programs.  Disconnect the user interface cable.  Execute the TEST3 program.  View the results of self-checking. Note: Install the SCP and USB driver for the E1 and E20 on the host computer (this step is only required once). Connect one end of the user-system interface connector to the user-side connector and the other end to the selfchecking connector on the emulator (see Figure A.1). Do not connect the USB interface connector yet. Connect the host computer and the emulator via the USB interface cable and turn on the power for the emulator. E1: The supply of power starts when the USB interface connector is connected. E20: The supply of power starts when the power switch is turned on after the USB interface cable has been connected. Initiate the SCP. Execute the TEST1 and TEST2 programs. Remove the cable from the self-checking connector. Execute the TEST3 program. If the results were normal, “PASS” will be displayed. If checking indicated a failure, “FAIL” will be displayed. In the case of “FAIL”, a further error message is also given. For the messages and their meanings, see Table A.1. Fault analysis of the hardware by using the self-checking program only works correctly when a single emulator is connected to the host computer. When two or more emulators are connected, correct operation is not guaranteed. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 29 of 40 E1/E20 Emulator Appendix A A.2 Preparations for Self-Checking (1) The following items are required to execute the self-checking program.  E1 or E20 emulator  USB interface cable (included in the package)  User interface cable (included in the package)  Installation medium (included in the package)  Host computer The emulator software and USB driver must also be installed on the host computer in advance. (2) Open the lid of the self-checking connector on the emulator. Then connect the user-side connector and selfchecking connector via the user interface cable. E1 Emulator E20 Emulator User-side connector User-side connector ACT ACT RESET RESET RUN RUN Self-checking connector Lid TOP VCC VCC SELF CHECK Self-checking connector Lid SE Figure A.1 Connecting the User Interface Cable (for the E1 and E20) CAUTION Insert the user interface cable firmly into the self-checking connector. If the connection is loose, the result will be “FAIL”. (3) Start up the host computer. Connect the host computer and the emulator via the USB interface cable and turn on the power for the emulator. The timing with which the supply of power starts differs with the emulator. E1: The supply of power starts when the USB interface connector is connected. E20: The supply of power starts when the power switch is turned on after the USB interface cable has been connected. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 30 of 40 E1/E20 Emulator Appendix A A.3 Executing the Self-Checking Program (1) Execute the E1/E20 Self Check Program (E1E20SCP.exe). When installing the High-performance Embedded Workshop RX E1/E20 debugger, open the start menu and select [Programs] -> [Renesas] -> [High-performance Embedded Workshop] -> [E1/E20 Self Check Program]. When installing the CubeSuite+, open the start menu and select [Programs] -> [Renesas Electronics CubeSuite+] -> [Emulator Utilities] -> [RX] -> [E1, E20 Emulator Self Check Program]. If you are using any other debugger product, refer to its manual, or install the self-checking program from included installation media, then open the start menu and select [Programs -> Renesas -> E1E20SCP -> E1E20 Self Check Program]. Figure A.2 Starting the Self-Checking Program R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 31 of 40 E1/E20 Emulator Appendix A (2) Click on the [START] button to start the self-checking program. If the user interface cable has not been connected to the self-checking connector, the following message is displayed: “Please connect the user interface cable to the self-check connector on E1 or E20 in a correct direction.” Check that the user interface cable is connected to the self-checking connector in the right direction as shown in Figure A.1, and click on the [OK] button. This starts the self-checking program. Figure A.3 Checking the Connection If the user interface cable has not been connected to the self-checking connector when the [OK] button is clicked on, “FAIL” is displayed on the screen (see figure below). Correctly connect the cable to the self-checking connector and click on the [START] button again to start the self-checking program. Figure A.4 [FAIL] at the Start of Self-Checking (without the Cable Connected to the Self-Checking Connector) R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 32 of 40 E1/E20 Emulator Appendix A If the user interface cable has been connected to the user system, “FAIL” is displayed on the screen (see figure below). Correctly connect the cable to the self-checking connector and click on the [START] button again to start the self-checking program. Figure A.5 [FAIL] at the Start of Self-Checking (with the Cable Connected to the User System) If the USB interface cable has been disconnected from the emulator, “FAIL” is displayed on the screen (see figure below). Correctly connect the cable and click on the [START] button again to start the self-checking program. Figure A.6 [FAIL] on Error with USB I/O Processing R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 33 of 40 E1/E20 Emulator Appendix A (3) As soon as the self-checking program is started. “TEST1 is running.” and “TEST2 is running.” are shown on the screen. If the emulator correctly completes TEST1 and TEST2, “TEST1: PASS” and “TEST2: PASS” are displayed. Figure A.7 Running the Self-Checking Program (4) When TEST3 is entered, the following message appears. “Please remove the User interface cable from the self-checking connector to execute TEST3.” After this message has been displayed, disconnect the user interface cable from the self-checking connector and close the lid of the self-checking connector. Then click on the [OK] button to continue with the self-checking process. If the user interface cable is still connected to the self-checking connector or user system, clicking on the [OK] button does not restart the self-checking process. Figure A.8 Message [Please remove the User interface cable from the self-checking connector to execute TEST3.] R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 34 of 40 E1/E20 Emulator Appendix A If you click on the [Cancel] button, “FAIL” is displayed on the screen (see figure below). Correctly connect the cable to the self-checking connector and click on the [START] button again to start the self-checking program. Figure A.9 [FAIL] Display that Appears When [Cancel] is Clicked on (5) As soon as the self-checking program is started. “TEST3 is running.” appears on the screen and self-checking continues. “PASS” or “FAIL” appears after TEST3 is completed. “PASS” indicates no problems with the emulator. Click on the [QUIT] button to end the self-checking program. Figure A.10 Normal Completion of Self-Checking R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 35 of 40 E1/E20 Emulator Appendix A In the case of failure, the word “FAIL” is displayed, followed by an error message in the center of the window. Table A.1 lists the error messages. Figure A.11 Display for an Error Found in Self-Checking Clicking on the [LOG] button opens the file selection dialog box. Specify the location where you want the results of self-checking to be saved. The results of self-checking are saved as a text file. Table A.1 Error Messages Message The E1/E20 self-check has failed. Please connect the user interface cable with the self-check connector in a correct direction. An error occurred during USB I/O processing. Description The user interface cable was connected to the user system at the time the self-checking program was started or there is a fault in the emulator. If the fault falls under the warranty conditions given in section 7, “Maintenance and Warranty”, we will correct the fault or replace the product for free. Correction or replacement in other cases incurs a fee. Correctly connect the user interface cable to the self-checking connector before starting the self-checking program. The USB interface cable was disconnected from the emulator during self-checking or there is a fault in the emulator. Connect the USB interface cable and restart the self-checking program. If the error recurs, it is due to a fault in the emulator. If the FAIL is displayed in the other error, please request the repair because the product is defective. R20UT0398EJ0401 Rev.4.01 Mar 15, 2016 Page 36 of 40 Revision History Rev. Date Description Page 4.01 Mar 15, 2016 14 Summary Regulatory Compliance Notices changed E1 Emulator R0E000010KCE00 E20 Emulator R0E000200KCT00 User’s Manual Publication Date: Mar 15, 2016 Rev.4.01 Published by: Renesas Electronics Corporation http://www.renesas.com SALES OFFICES Refer to "http://www.renesas.com/" for the latest and detailed information. Renesas Electronics America Inc. 2801 Scott Boulevard Santa Clara, CA 95050-2549, U.S.A. Tel: +1-408-588-6000, Fax: +1-408-588-6130 Renesas Electronics Canada Limited 9251 Yonge Street, Suite 8309 Richmond Hill, Ontario Canada L4C 9T3 Tel: +1-905-237-2004 Renesas Electronics Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K Tel: +44-1628-585-100, Fax: +44-1628-585-900 Renesas Electronics Europe GmbH Arcadiastrasse 10, 40472 Düsseldorf, Germany Tel: +49-211-6503-0, Fax: +49-211-6503-1327 Renesas Electronics (China) Co., Ltd. Room 1709, Quantum Plaza, No.27 ZhiChunLu Haidian District, Beijing 100191, P.R.China Tel: +86-10-8235-1155, Fax: +86-10-8235-7679 Renesas Electronics (Shanghai) Co., Ltd. Unit 301, Tower A, Central Towers, 555 Langao Road, Putuo District, Shanghai, P. R. China 200333 Tel: +86-21-2226-0888, Fax: +86-21-2226-0999 Renesas Electronics Hong Kong Limited Unit 1601-1611, 16/F., Tower 2, Grand Century Place, 193 Prince Edward Road West, Mongkok, Kowloon, Hong Kong Tel: +852-2265-6688, Fax: +852 2886-9022 Renesas Electronics Taiwan Co., Ltd. 13F, No. 363, Fu Shing North Road, Taipei 10543, Taiwan Tel: +886-2-8175-9600, Fax: +886 2-8175-9670 Renesas Electronics Singapore Pte. Ltd. 80 Bendemeer Road, Unit #06-02 Hyflux Innovation Centre, Singapore 339949 Tel: +65-6213-0200, Fax: +65-6213-0300 Renesas Electronics Malaysia Sdn.Bhd. Unit 1207, Block B, Menara Amcorp, Amcorp Trade Centre, No. 18, Jln Persiaran Barat, 46050 Petaling Jaya, Selangor Darul Ehsan, Malaysia Tel: +60-3-7955-9390, Fax: +60-3-7955-9510 Renesas Electronics India Pvt. Ltd. No.777C, 100 Feet Road, HAL II Stage, Indiranagar, Bangalore, India Tel: +91-80-67208700, Fax: +91-80-67208777 Renesas Electronics Korea Co., Ltd. 12F., 234 Teheran-ro, Gangnam-Gu, Seoul, 135-080, Korea Tel: +82-2-558-3737, Fax: +82-2-558-5141 © 2016 Renesas Electronics Corporation. All rights reserved. Colophon 4.0 E1 Emulator R0E000010KCE00 E20 Emulator R0E000200KCT00 User’s Manual R20UT0398EJ0401
R0E000010KCE00 价格&库存

很抱歉,暂时无法提供与“R0E000010KCE00”相匹配的价格&库存,您可以联系我们找货

免费人工找货