0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
84DUE92EMF

84DUE92EMF

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    STARTER,DUPLEX,S1,SSOLR,120VAC,M

  • 数据手册
  • 价格&库存
84DUE92EMF 数据手册
Data sheet US2:84DUE92EMF Duplex starter with alternator Size 1 Three phase full voltage Solid-state overload relay OLRelay amp range 10-40a 110VAC 50HZ / 120VAC 60HZ coil Combination type Two 30A circuit breakers Encl NEMA type 4 painted steel Water/dust tight weather proof product brand name Class 84 design of the product Duplex controller with two MCPs with alternator special product feature ESP200 overload relay General technical data weight [lb] Height x Width x Depth [in] 70 lb touch protection against electrical shock NA for enclosed products installation altitude [ft] at height above sea level maximum 6560 ft 34 × 25 × 8 in ambient temperature [°F] ● during storage -22 ... +149 °F ● during operation -4 ... +104 °F ambient temperature ● during storage -30 ... +65 °C ● during operation -20 ... +40 °C country of origin USA Horsepower ratings yielded mechanical performance [hp] for 3-phase AC motor ● at 200/208 V rated value 7.5 hp ● at 220/230 V rated value 7.5 hp ● at 460/480 V rated value 0 hp ● at 575/600 V rated value 0 hp Contactor size of contactor NEMA controller size 1 number of NO contacts for main contacts 3 operating voltage for main current circuit at AC at 60 Hz maximum 600 V operational current at AC at 600 V rated value 27 A mechanical service life (switching cycles) of the main contacts typical 10000000 Auxiliary contact number of NC contacts at contactor for auxiliary contacts 0 number of NO contacts at contactor for auxiliary contacts 1 number of total auxiliary contacts maximum 8 contact rating of auxiliary contacts of contactor according to UL 10A@600VAC (A600), 5A@600VDC (P600) Coil US2:84DUE92EMF Page 1/2 1.14.2021 Subject to change without notice © Copyright Siemens type of voltage of the control supply voltage AC control supply voltage ● at DC rated value 0 ... 0 V ● at AC at 50 Hz rated value 110 ... 110 V ● at AC at 60 Hz rated value 120 ... 120 V holding power at AC minimum 8.6 W apparent pick-up power of magnet coil at AC 218 V·A apparent holding power of magnet coil at AC 25 V·A operating range factor control supply voltage rated value of magnet coil 0.85 ... 1.1 percental drop-out voltage of magnet coil related to the input voltage 50 % switch ON delay time 19 ... 29 ms OFF delay time 10 ... 24 ms Overload relay product function ● overload protection Yes ● phase failure detection Yes ● asymmetry detection Yes ● ground fault detection Yes ● test function Yes ● external reset Yes reset function Manual, automatic and remote trip class Class 5 / 10 / 20 (factory set) / 30 adjustable current response value current of the currentdependent overload release 10 ... 40 A tripping time at phase-loss maximum 3s relative repeat accuracy 1% product feature protective coating on printed-circuit board Yes number of NC contacts of auxiliary contacts of overload relay 1 number of NO contacts of auxiliary contacts of overload relay 1 operational current of auxiliary contacts of overload relay ● at AC at 600 V 5A ● at DC at 250 V 1A contact rating of auxiliary contacts of overload relay according to UL 5A@600VAC (B600), 1A@250VDC (R300) insulation voltage ● with single-phase operation at AC rated value 600 V ● with multi-phase operation at AC rated value 300 V Enclosure degree of protection NEMA rating of the enclosure NEMA Type 4 design of the housing Dust-tight, watertight & weather proof Circuit Breaker type of the motor protection Motor circuit protector (magnetic trip only) operational current of motor circuit breaker rated value 30 A adjustable current response value current of instantaneous short-circuit trip unit 80 ... 270 A Mounting/wiring mounting position Vertical fastening method Surface mounting and installation type of electrical connection for supply voltage line-side Box lug type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 1x (10 AWG ... 1/0 AWG) temperature of the conductor for supply maximum permissible 75 °C material of the conductor for supply AL or CU type of electrical connection for load-side outgoing feeder Screw-type terminals tightening torque [lbf·in] for load-side outgoing feeder 35 ... 35 lbf·in US2:84DUE92EMF Page 2/3 1.14.2021 Subject to change without notice © Copyright Siemens type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multistranded 1x (14 ... 2 AWG) temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C material of the conductor for load-side outgoing feeder AL or CU type of electrical connection of magnet coil Screw-type terminals tightening torque [lbf·in] at magnet coil 5 ... 12 lbf·in type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 ... 12 AWG) temperature of the conductor at magnet coil maximum permissible 75 °C material of the conductor at magnet coil CU type of electrical connection at contactor for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at contactor for auxiliary contacts 10 ... 15 lbf·in type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multistranded 1x (12 AWG), 2x (16 ... 14 AWG), 2x (18 ... 16 AWG) temperature of the conductor at contactor for auxiliary contacts maximum permissible 75 °C material of the conductor at contactor for auxiliary contacts CU type of electrical connection at overload relay for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at overload relay for auxiliary contacts 7 ... 10 lbf·in type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multistranded 2x (20 ... 14 AWG) temperature of the conductor at overload relay for auxiliary contacts maximum permissible 75 °C material of the conductor at overload relay for auxiliary contacts CU Short-circuit current rating design of the short-circuit trip Instantaneous trip circuit breaker breaking capacity maximum short-circuit current (Icu) ● at 240 V 100 kA ● at 480 V 100 kA ● at 600 V 25 kA certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No.14 Further information Industrial Controls - Product Overview (Catalogs, Brochures,…) www.usa.siemens.com/iccatalog Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:84DUE92EMF Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/US/en/ps/US2:84DUE92EMF Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:84DUE92EMF&lang=en Certificates/approvals https://support.industry.siemens.com/cs/US/en/ps/US2:84DUE92EMF/certificate US2:84DUE92EMF Page 3/4 1.14.2021 Subject to change without notice © Copyright Siemens US2:84DUE92EMF Page 4/5 1.14.2021 Subject to change without notice © Copyright Siemens last modified: US2:84DUE92EMF Page 5/5 3/27/2020 1.14.2021 Subject to change without notice © Copyright Siemens
84DUE92EMF 价格&库存

很抱歉,暂时无法提供与“84DUE92EMF”相匹配的价格&库存,您可以联系我们找货

免费人工找货