TDA75613LV
4 x 45 W power amplifier with full I2C diagnostics, high efficiency,
SSR and low voltage operation
Datasheet - production data
ESD protection
Very robust against misconnections
Improved SVR suppression during battery
transients
Capable to operate down to 6 V (e.g. “Start-stop”)
'!0'03
Flexiwatt27 (vertical)
SSR (speaker safety routine)
Features
Description
Multipower BCD technology
The TDA75613LV is a new quad bridge car radio
amplifier, designed in BCD technology, in order to
include a wide range of innovative features in a
very compact and flexible device.
MOSFET output power stage
DMOS power output
High efficiency (class SB)
High output power capability 4x25 W/4 Ω @
14.4 V, 1 kHz, 10% THD, 4 x 45 W max power
2 Ωdriving capability (64 W max power)
2
Full I C bus driving:
– Standby
– Independent front/rear soft play/mute
– Selectable gain 30 dB /16 dB (for low noise
line output function)
– High efficiency enable/disable
– I2C bus digital diagnostics (including DC
and AC load detection)
Flexible fault detection through integrated
diagnostic
DC offset detection
Four independent short circuit protection
Clipping detector pin with selectable threshold
(2 %/10 %)
Standby/mute pin
The TDA75613LV is equipped with the most
complete diagnostics array that communicates
the status of each speaker through the I2C bus.
The dissipated output power under average
listening condition is significantly reduced when
compared to the conventional class AB solutions,
thanks to the patented 'class SB' efficiency
concept. TDA75613LV has been designed to be
very robust against several kinds of
misconnections.
The TDA75613LV is equipped with the SSR
(speaker safety routine), a procedure able to
check the offset at the speakers and automatically
shut down the power amplifier in case of
dangerous DC voltage.
It is moreover compliant to the most recent OEM
specifications for low voltage operation (so called
'start-stop' battery profile during engine stop),
helping car manufacturers to reduce the overall
emissions and thus contributing to environment
protection.
Linear thermal shutdown with multiple thermal
warning
Table 1. Device summary
Order code
Package
Packing
TDA75613LV
Flexiwatt27 (vertical)
Tube
September 2014
This is information on a product in full production.
DocID025640 Rev 5
1/39
www.st.com
Contents
TDA75613LV
Contents
1
Block diagram and application circuits . . . . . . . . . . . . . . . . . . . . . . . . . 6
2
Pins description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3
Electrical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4
5
6
3.1
Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.2
Thermal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3.3
Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.4
Electrical characteristic curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Diagnostics functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.1
Turn-on diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.2
Permanent diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.3
AC diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Output DC offset detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.1
Offset detection and mute at start-up, SSR (Speaker Safety Routine) . . 22
5.2
Offset detection in normal operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Multiple faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.1
7
Thermal protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.1
8
9
8.1
Low voltage operation (“start stop”) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8.2
Advanced battery management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Application suggestion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
High efficiency introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
I2C bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10.1
2/39
Fast muting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Battery transitions management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
9.1
10
Faults availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
I2C programming/reading sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
DocID025640 Rev 5
TDA75613LV
Contents
10.2
Address selection and I2C disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10.3
I2C bus interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10.3.1
Data validity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
10.3.2
Start and stop conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
10.3.3
Byte format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
10.3.4
Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
11
Software specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
12
Examples of bytes sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
13
Package information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
14
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
DocID025640 Rev 5
3/39
3
List of tables
TDA75613LV
List of tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
4/39
Device summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Pins list description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Thermal data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Double fault table for turn on diagnostic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
IB1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
IB2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
DB1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
DB2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
DB3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
DB4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
DocID025640 Rev 5
TDA75613LV
List of figures
List of figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Figure 10.
Figure 11.
Figure 12.
Figure 13.
Figure 14.
Figure 15.
Figure 16.
Figure 17.
Figure 18.
Figure 19.
Figure 20.
Figure 21.
Figure 22.
Figure 23.
Figure 24.
Figure 25.
Figure 26.
Figure 27.
Figure 28.
Figure 29.
Figure 30.
Figure 31.
Figure 32.
Figure 33.
Figure 34.
Figure 35.
Figure 36.
Figure 37.
Figure 38.
Figure 39.
Figure 40.
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Application circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pins connection diagram (top of view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Quiescent current vs. supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Output power vs. supply voltage (4 Ω) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Distortion vs. output power (4 Ω, STD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Distortion vs. output power (4 Ω, HI-EFF). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Distortion vs. output power (2 Ω, STD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Distortion vs. output power (2 Ω, HI-EFF). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Distortion vs. frequency (2 Ω, 8W,STD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Distortion vs. output power Vs = 6 V (4 Ω, STD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Distortion vs. frequency (4 Ω, 4W, STD). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Crosstalk vs. frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Supply voltage rejection vs. frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Power dissipation vs. average Po (audio program simulation, 2 Ω) . . . . . . . . . . . . . . . . . . 15
Power dissipation vs. average Po (audio program simulation, 4 Ω) . . . . . . . . . . . . . . . . . . 16
Total power dissipation & efficiency vs.output power (4 Ω, HI-EFF, Sine) . . . . . . . . . . . . . 16
Total power dissipation & efficiency vs. output power (4 Ω, STD, Sine). . . . . . . . . . . . . . . 16
ITU R-ARM frequency response, weighting filter for transient pop. . . . . . . . . . . . . . . . . . . 16
Turn-on diagnostic: working principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SVR and output behavior (Case 1: without turn-on diagnostic) . . . . . . . . . . . . . . . . . . . . . 17
SVR and output pin behavior (Case 2: with turn-on diagnostic) . . . . . . . . . . . . . . . . . . . . . 18
Short circuit detection thresholds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Load detection thresholds - high gain setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Load detection threshold - low gain setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Restart timing without diagnostic enable (permanent) - Each 1 mS time,
a sampling of the fault is done . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Restart timing with diagnostic enable (permanent). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Current detection high: load impedance |Z| vs. output peak voltage . . . . . . . . . . . . . . . . . 21
Current detection low: load impedance |Z| vs. output peak voltage . . . . . . . . . . . . . . . . . . 21
Power on sequence with a detected offset lower than 2 V . . . . . . . . . . . . . . . . . . . . . . . . . 22
Power on sequence with a detected offset higher than 2 V . . . . . . . . . . . . . . . . . . . . . . . . 23
Thermal foldback diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Worst case battery cranking curve sample 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Worst case battery cranking curve sample 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Upwards fast battery transitions diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
High efficiency - basic structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Data validity on the I2C bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Timing diagram on the I2C bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Acknowledge on the I2C bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Flexiwatt27 (vertical) mechanical data and package dimensions . . . . . . . . . . . . . . . . . . . . 37
DocID025640 Rev 5
5/39
5
Block diagram and application circuits
1
TDA75613LV
Block diagram and application circuits
Figure 1. Block diagram
#,+
$!4!
6##
6##
34
"9-54%
4HERMAL
0ROTECTION
$UMP
)#"53
-UTE -UTE
).
#$?/54
#LIP
$ETECTOR
2EFERENCE
&
/54
D"
/54
3HORT#IRCUIT
0ROTECTION
$IAGNOSTIC
).
2
/54
D"
).
/54
3HORT#IRCUIT
0ROTECTION
$IAGNOSTIC
&
/54
D"
).
3HORT#IRCUIT
0ROTECTION
$IAGNOSTIC
2
/54
/54
D"
3HORT#IRCUIT
0ROTECTION
$IAGNOSTIC
!#?'.$
362
!$SEL
3'.$
4! "
/54
!$3%,
)#$)3
07 ?'.$
'!0'03
Figure 2. Application circuit
6S
#
&
666CC
#
&
6CC
K7 34
"9
6CC
/54
$!4!
#,+
)#"53
/54
).
).
).
#&
#&
4$!,6
/54
).
).
).
#&
#&
/54
3'.$
!#'.$
#
&
!$3%,)#$)3
362
4!"
2K7
#
&
6
#$
'!0'03
6/39
DocID025640 Rev 5
TDA75613LV
2
Pins description
Pins description
For channel name reference: CH1 = LF, CH2 = LR, CH3 = RF and CH4 = RR.
Figure 3. Pins connection diagram (top of view)
!$3%,)#$)3
$!4!
07'.$
/54
#+
/54
6##
/54
07'.$
/54
!#'.$
).
).
3'.$
).
).
362
/54
07'.$
/54
6##
/54
#$
/54
/54
07'.$
34"9
4!"
&LEXIWATTVERTICAL
DocID025640 Rev 5
'!0'03
7/39
38
Pins description
TDA75613LV
Table 2. Pins list description
Pin #
Pin name
1
TAB
2
STBY
3
PWGND2
4
OUT2-
5
CD
6
OUT2+
Channel 2, + output
7
VCC1
Supply voltage pin1
8
OUT1-
Channel 1, - output
9
PWGND1
10
OUT1+
11
SVR
SVR pin
12
IN1
Input pin, channel 1
13
IN2
Input pin, channel 2
14
SGND
15
IN4
Input pin, channel 4
16
IN3
Input pin, channel 3
17
AC GND
18
OUT3+
19
PWGND3
20
OUT3-
Channel 3, - output
21
VCC2
Supply voltage pin2
22
OUT4+
Channel 4, + output
23
CK
24
OUT4-
25
PWGND4
26
DATA
27
8/39
Function
Standby pin
Channel 2 output power ground
Channel 2, - output
Clip detector output pin
Channel 1 output power ground
Channel 1, + output
Signal ground pin
AC ground
Channel 3, + output
Channel 3 output power ground
I2C bus clock/HE selector
Channel 4, - output
Channel 4 output power ground
I2C bus data pin/gain selector
ADSEL/I2CDIS Address selector pin/ I2C bus disable (legacy select)
DocID025640 Rev 5
TDA75613LV
Electrical specifications
3
Electrical specifications
3.1
Absolute maximum ratings
Table 3. Absolute maximum ratings
Symbol
Parameter
(1)
Value
Unit
18
V
Vop
Operating supply voltage
VS
DC supply voltage
28
V
Peak supply voltage (for tmax = 50 ms)
50
V
-0.3 to 0.3
V
-0.3 to 6
V
Vpeak
GNDmax
VCK, VDATA
Ground pins voltage
CK and DATA pin voltage
Vcd
Clip detector voltage
-0.3 to 5.5
V
Vstby
STBY pin voltage
-0.3 to Vop
V
IO
Ptot
Tstg, Tj
Tamb
Output peak current (not repetitive tmax = 100ms)
8
Output peak current (repetitive f > 10 kHz)
6
Power dissipation Tcase = 70°C
85
W
-55 to 150
°C
-40 to +105
°C
Storage and junction
temperature(2)
Operative temperature range
A
1. For RL = 2 Ω the output current limit might be reached for VOP > 16 V; thus triggering self-protection.
2. A suitable dissipation system should be used to keep Tj inside the specified limits.
3.2
Thermal data
Table 4. Thermal data
Symbol
Rth j-case
Parameter
Thermal resistance junction-to-case
DocID025640 Rev 5
Max.
Value
Unit
1
°C/W
9/39
38
Electrical specifications
3.3
TDA75613LV
Electrical characteristics
Refer to the test circuit, VS = 14.4 V; RL = 4 Ω; f = 1 kHz; GV = 30 dB; Tamb = 25 °C;
unless otherwise specified.
Table 5. Electrical characteristics
Symbol
Parameter
Test condition
Min.
Typ.
Max.
RL = 4 ohm
6
-
18
RL = 2 ohm
6
-
16 (1)
Unit
General characteristics
VS
Supply voltage range
Id
Total quiescent drain current
-
-
165
250
mA
RIN
Input impedance
-
45
60
70
kΩ
VAM
Min. supply mute threshold
7
-
8
5
-
6
VOS
Offset voltage
Mute & play
-100
0
100
mV
Vdth
Dump threshold
-
18.5
19.5
20.5
V
ISB
Standby current
Vstandby = 0
-
1
5
µA
SVR
Supply voltage rejection
f = 100 Hz to 10 kHz; Vr = 1 Vpk;
Rg = 600 Ω
55
60
-
dB
TON
Turn on timing (Mute play
transition)
D2/D1 (IB1) 0 to 1
-
25
50
ms
TOFF
Turn off timing (Play mute
transition)
D2/D1 (IB1) 1 to 0
-
25
50
ms
IB1(D7) = 1
IB1(D7) = 0
(default)(2)
V
V
THWARN1
Average junction temperature for
DB1 (D7) = 1
TH warning 1
-
160
-
THWARN2
Average junction temperature for
DB4 (D7) = 1
TH warning 2
-
145
-
THWARN3
Average junction temperature for
DB4 (D6) = 1
TH warning 3
-
125
-
-
45
-
W
23
-
25
22
-
W
W
RL = 2 Ω; THD 10 %
RL = 2 Ω; THD 1 %
RL = 2 Ω; Max. power(3) Vs = 14.4 V
-
44
33
64
-
W
W
W
Max power@ Vs = 6 V, RL = 4 Ω
-
5
-
W
°C
Audio performances
Max. power(3) Vs = 15.2 V, RL = 4 Ω
THD = 10 %, RL = 4 Ω
THD = 1 %, RL = 4 Ω
PO
10/39
Output power
DocID025640 Rev 5
TDA75613LV
Electrical specifications
Table 5. Electrical characteristics (continued)
Symbol
THD
Parameter
Total harmonic distortion
Test condition
Min.
Typ.
Max.
Unit
PO = 1 W to 10 W; STD mode
HE MODE; PO = 1.5 W
HE MODE; PO = 8 W
-
0.015
0.05
0.1
0.1
0.1
0.5
%
%
%
PO = 1-10 W, f = 10 kHz
-
0.15
0.5
%
GV = 16 dB; STD Mode
VO = 0.1 to 5 VRMS
-
0.02
0.05
%
CT
Cross talk
f = 1 kHz to 10 kHz, Rg = 600 Ω
50
65
-
dB
GV1
Voltage gain 1
-
29
30
31
dB
Voltage gain match 1
-
-1
-
1
dB
Voltage gain 2
-
15
16
17
dB
GV2
Voltage gain match 2
-
-1
-
1
dB
EIN1
Output noise voltage 1
Rg = 600 Ω 20 Hz to 22 kHz
-
65
80
µV
EIN2
Output noise voltage 2
Rg = 600 Ω; GV = 16d B
20 Hz to 22 kHz
-
20
30
µV
BW
Power bandwidth
-
100
-
-
kHz
Input CMRR
VCM = 1 Vpk-pk; Rg = 0 Ω
-
70
-
dB
-10
-
10
mV
-10
-
10
mV
GV1
GV2
CMRR
VOS
During mute ON/OFF output
offset voltage
During standby ON/OFF output
offset voltage
ITU R-ARM weighted
(see Figure 18)
Clip detector
CDLK
Clip det. high leakage current
CD off / VCD = 6 V
-
0
5
µA
CDSAT
Clip det sat. voltage
CD on; ICD = 1 mA
-
-
300
mV
CDTHD
Clip det THD level
D0 (IB1) = 1
5
10
15
%
D0 (IB1) = 0
1
2
3
%
Control pin characteristics
VSBY
Standby/mute pin for standby
-
0
-
1.2
V
VMU
Standby/mute pin for mute
-
2.9
-
3.5
V
VOP
Standby/mute pin for operating
-
4.5
-
18
V
IMU
Standby/mute pin current
Vst-by/mute = 4.5 V
-
1
5
µA
Vst-by/mute < 1.2 V
-
0
5
µA
ASB
Standby attenuation
-
90
110
-
dB
AM
Mute attenuation
-
80
100
-
dB
DocID025640 Rev 5
11/39
38
Electrical specifications
TDA75613LV
Table 5. Electrical characteristics (continued)
Symbol
Parameter
Test condition
Min.
Typ.
Max.
Unit
Turn on diagnostics 1 (Power amplifier mode)
Pgnd
Short to GND det. (below this
limit, the Output is considered in
short circuit to GND)
-
-
1.2
V
Pvs
Short to Vs det. (above this limit,
the output is considered in short
circuit to Vs)
Vs -1.2
-
-
V
1.8
-
Vs -1.8
V
-
-
0.5
Ω
Pnop
Power amplifier in standby
Normal operation thresholds.
(Within these limits, the output is
considered without faults).
Lsc
Shorted load det.
Lop
Open load det.
85
-
-
Ω
Lnop
Normal load det.
1.5
-
45
Ω
-
-
1.2
V
Turn on diagnostics 2 (Line driver mode)
Pgnd
Short to GND det. (below this
limit, the output is considered in
short circuit to GND)
Power amplifier in standby
Pvs
Short to Vs det. (above this limit,
the output is considered in short circuit to Vs)
Vs -1.2
-
-
V
Pnop
Normal operation thresholds.
(Within these limits, the output is considered without faults).
1.8
-
Vs -1.8
V
Lsc
Shorted load det.
-
-
-
1.5
Ω
Lop
Open load det.
-
330
-
-
Ω
Lnop
Normal load det.
-
7
-
180
Ω
-
-
1.2
V
Vs -1.2
-
-
V
1.8
-
Vs -1.8
V
Power amplifier mode
-
-
0.5
Ω
Line driver mode
-
-
1.5
Ω
±1.5
±2
±2.5
V
Permanent diagnostics 2 (Power amplifier mode or line driver mode)
Pgnd
Pvs
Pnop
Short to GND det. (below this
limit, the Output is considered in
short circuit to GND)
Short to Vs det. (above this limit, Power amplifier in mute or play,
the output is considered in short one or more short circuits
protection activated
circuit to Vs)
Normal operation thresholds.
(Within these limits, the output is
considered without faults).
LSC
Shorted load det.
VO
Offset detection
12/39
Power amplifier in play,
AC input signals = 0
DocID025640 Rev 5
TDA75613LV
Electrical specifications
Table 5. Electrical characteristics (continued)
Symbol
I
Parameter
INLH
Normal load current detection
IOLH
Open load current detection
INLL
Normal load current detection
IOLL
Open load current detection
2C
Test condition
VO < (VS-5)pk, IB2 (D7) = 0
VO < (VS-5)pk, IB2 (D7) = 1
Min.
Typ.
Max.
Unit
500
-
-
mA
-
-
250
mA
250
-
-
mA
-
-
125
mA
bus interface
SCL
Clock frequency
-
-
-
400
kHz
VIL
Input low voltage
-
-
-
1.5
V
VIH
Input high voltage
-
2.3
-
-
V
1. When VS > 16 V the output current limit is reached (triggering embedded internal protections).
2. In legacy mode only low threshold option is available.
3. Saturated square wave output.
DocID025640 Rev 5
13/39
38
Electrical specifications
3.4
TDA75613LV
Electrical characteristic curves
Figure 4. Quiescent current vs. supply voltage Figure 5. Output power vs. supply voltage (4 Ω)
,TP$
9LQ
12/2$'6
3R:
5/ ȍ
I N+]
3RPD[
7+'
7+'
9V9
*$3*36
Figure 6. Distortion vs. output power (4 Ω, STD)
9V9
7+ '
*$3*36
7+ '
9V 9
5/ ȍ
I N+]
I N+]
I N+]
I N+]
3 R:
3 R:
*$3*36
*$3*36
Figure 8. Distortion vs. output power (2 Ω, STD)
7+'
Figure 7. Distortion vs. output power
(4 Ω, HI-EFF)
9V 9
5/ ȍ
Figure 9. Distortion vs. output power
(2 Ω, HI-EFF)
67$1'$5' 02'(
9V 9
5/ ȍ
7+'
+,())02'(
9V 9
5/ ȍ
I N+]
I N+]
I N+]
I N+]
3R:
*$3*36
14/39
DocID025640 Rev 5
3R:
*$3*36
TDA75613LV
Electrical specifications
Figure 10. Distortion vs. frequency (2 Ω,
8W,STD)
Figure 11. Distortion vs. output power Vs = 6 V
(4 Ω, STD)
7+'
7+ '
9V 9
5/ ȍ
9V 9
5/ ȍ
3R :
I N+]
I N+]
I+]
Figure 13. Crosstalk vs. frequency
7+'
9V 9
5/ ȍ
3R :
*$3*36
Figure 12. Distortion vs. frequency (4 Ω, 4W,
STD)
3 R:
*$3*36
&52667$/.G%
67$1'$5' 02'(
5/ ȍ
3R :
5J ȍ
I+]
I+]
*$3*36
Figure 14. Supply voltage rejection vs.
frequency
695G%
*$3*36
Figure 15. Power dissipation vs. average Po
(audio program simulation, 2 Ω)
67' +(02'(
5J ȍ
9ULSSOH 9UPV
9V 9
5/ [ȍ
3LQN1RLVH
&/,367$57
3WRW:
I+]
*$3*36
DYJ3R:
DocID025640 Rev 5
*$3*36
15/39
38
Electrical specifications
TDA75613LV
Figure 16. Power dissipation vs. average Po
(audio program simulation, 4 Ω)
Figure 17. Total power dissipation & efficiency
vs.output power (4 Ω, HI-EFF, Sine)
3 WR W:
9V 9
5/ [ȍ
3LQN1RLVH
3WRW:
Ș
9V 9
5/ ȍ
I N+]
Ș
&/,367$57
Ș
0TOT 7
9V 9
5/ ȍ
I N+]
Ș
0TOT
16/39
3R:FK
3RZFK
Figure 19. ITU R-ARM frequency response,
weighting filter for transient pop
*$3*36
Figure 18. Total power dissipation & efficiency
vs. output power (4 Ω, STD, Sine)
*$3*36
DY J 3 R :
0TOT
/UTPUTATTENUATIOND"
*$3*36
DocID025640 Rev 5
(Z
*$3*36
TDA75613LV
Diagnostics functional description
4
Diagnostics functional description
4.1
Turn-on diagnostic
It is recommended to activate this function at the turn-on (standby out) through an I2C bus
request. Detectable output faults are:
Short to GND
Short to Vs
Short across the speaker
Open speaker
To verify if any of the above misconnections are in place, a subsonic (inaudible) current
pulse (Figure 20) is internally generated, sent through the speaker(s) and sunk back.The
Turn On diagnostic status is internally stored until a successive diagnostic pulse is
requested (after a I2C reading).
If the "standby out" and "diag. enable" commands are both given through a single
programming step, the pulse takes place first (during the pulse the power stage stays 'off',
showing high impedance at the outputs).
Afterwards, when the Amplifier is biased, the PERMANENT diagnostic takes place. The
previous turn-on state is kept until a short appears at the outputs.
Figure 20. Turn-on diagnostic: working principle
9Va9
,VRXUFH
,P$
,VRXUFH
,VLQN
,VLQN
aPV
WPV
0HDVXUHWLPH
'!0'03
Figure 21 and 22 show SVR and OUTPUT waveforms at the turn-on (standby out) with and
without turn-on diagnostic.
Figure 21. SVR and output behavior (Case 1: without turn-on diagnostic)
6SVR
/UT
0ERMANENTDIAGNOSTIC
ACQUISITIONTIMEMS4YP
T
"IASPOWER AMPT URN
ON
$IAGNOSTIC %NABLE
0ERMANENT
)#"$!4!
&!5,4
EVENT
0ERMANENT$IAGNOSTICSDATAOUPUT
PERMITTEDTIME
DocID025640 Rev 5
2EAD$ATA
'!0'03
17/39
38
Diagnostics functional description
TDA75613LV
Figure 22. SVR and output pin behavior (Case 2: with turn-on diagnostic)
6SVR
/UT
4U RN
OND IAGNOSTIC
ACQU ISI TIONTIM EMS 4YP
0ERMANENTDIAGN OST IC
ACQUI SIT IONTIMEMS 4YP
T
4URN
ON $IAGN OST ICS DATAOUT PU T
PER MITT EDTI ME
$IAGNOST IC%NABLE
4UR N
ON
"IASPOWERAMP TURN
ON
PERMITTE DT IME
$IAGN OST IC% NABLE
0ERMAN ENT
2EAD$ATA
&!5,4
EVENT
0ERMANENT$IAGNO ST ICS DAT AOUT PUT
PERMITTE DTIME
)#"$!4!
'!0'03
The information related to the outputs status is read and memorized at the end of the
current pulse plateau. The acquisition time is 100 ms (typ.). No audible noise is generated in
the process. As for SHORT TO GND / Vs the fault-detection thresholds remain unchanged
from 30 dB to 16 dB gain setting. They are as follows:
Figure 23. Short circuit detection thresholds
3#TO'.$
6
X
6
.ORMAL/PERATION
6
X
63
6
3#TO6S
63
6
63
'!0'03
Concerning SHORT ACROSS THE SPEAKER / OPEN SPEAKER, the threshold varies
from 30 dB to 16 dB gain setting, since different loads are expected (either normal speaker's
impedance or high impedance). The values in case of 30 dB gain are as follows:
Figure 24. Load detection thresholds - high gain setting
3#ACROSS,OAD
6
X
7
.ORMAL/PERATION
7
X
/PEN,OAD
7
7
)NFINITE
'!0'03
If the Line-Driver mode (Gv= 16 dB and Line Driver Mode diagnostic = 1) is selected, the
same thresholds will change as follows:
Figure 25. Load detection threshold - low gain setting
3#ACROSS,OAD
7
7
X
.ORMAL/PERATION
7
7
X
/PEN,OAD
7
INFINITE
'!0'03
18/39
DocID025640 Rev 5
TDA75613LV
4.2
Diagnostics functional description
Permanent diagnostics
Detectable conventional faults are:
Short to GND
Short to Vs
Short across the speaker
The following additional feature is provided:
Output offset detection (see Section 5)
The TDA75613LV has 2 operating status:
1.
RESTART mode. The diagnostic is not enabled. Each audio channel operates
independently of each other. If any of the a.m. faults occurs, only the channel(s)
interested is shut down. A check of the output status is made every 1 ms (Figure 26).
Restart takes place when the overload is removed.
2.
DIAGNOSTIC mode. It is enabled via I2C bus and it self activates if an output overload
(such as to cause the intervention of the short-circuit protection) occurs to the speakers
outputs. Once activated, the diagnostics procedure develops as follows (Figure 27):
–
To avoid momentary re-circulation spikes from giving erroneous diagnostics, a
check of the output status is made after 1ms: if normal situation (no overloads) is
detected, the diagnostic is not performed and the channel returns active.
–
Instead, if an overload is detected during the check after 1 ms, then a diagnostic
cycle having a duration of about 100 ms is started.
–
After a diagnostic cycle, the audio channel interested by the fault is switched to
RESTART mode. The relevant data are stored inside the device and can be read
by the microprocessor. When one cycle has terminated, the next one is activated
by an I2C reading. This is to ensure continuous diagnostics throughout the carradio operating time.
–
To check the status of the device a sampling system is needed. The timing is
chosen at microprocessor level (over half a second is recommended).
Figure 26. Restart timing without diagnostic enable (permanent) - Each 1 mS time, a
sampling of the fault is done
/UT
M3
M3
M3
M3
M3
T
/VERCUR RENTAND SHOR T
CIRCUIT PROTECT IONI NTERVENT ION
IESHOR TCIRCUI TT O'.$
3HOR TCI RCUI TREMOVED
'!0'03
Figure 27. Restart timing with diagnostic enable (permanent)
M3
M3
M3
M3
T
/VERCURRENT ANDSHORT
CIRCUITPROTECTI ON IN TERVENTI ON
IES HORTC IRCUI TTO'.$
3HO RTCIRCUIT REMOVED
'!0'03
DocID025640 Rev 5
19/39
38
Diagnostics functional description
4.3
TDA75613LV
AC diagnostic
It is targeted at detecting accidental disconnection of tweeters in 2-way speaker and, more
in general, presence of capacitive (AC) coupled loads.
This diagnostic is based on the notion that the overall speaker's impedance (woofer +
parallel tweeter) will tend to increase towards high frequencies if the tweeter gets
disconnected, because the remaining speaker (woofer) would be out of its operating range
(high impedance). The diagnostic decision is made according to peak output current
thresholds, and it is enabled by setting (IB2-D2) = 1. Two different detection levels are
available:
–
High current threshold IB2 (D7) = 0
Iout > 500 mApk = normal status
Iout < 250 mApk = open tweeter
–
Low current threshold IB2 (D7) = 1
Iout > 250 mApk = normal status
Iout < 125 mApk = open tweeter
To correctly implement this feature, it is necessary to briefly provide a signal tone (with the
amplifier in "play") whose frequency and magnitude are such to determine an output current
higher than 500 mApk with IB2(D7) = 0 (higher than 250 mApk with IB2(D7) = 1) in normal
conditions and lower than 250 mApk with IB2(D7) = 0 (lower than 125 mApk with
IB2(D7)=1) should the parallel tweeter be missing.
The test has to last for a minimum number of 3 sine cycles starting from the activation of the
AC diagnostic function IB2) up to the I2C reading of the results (measuring period). To
confirm presence of tweeter, it is necessary to find at least 3 current pulses over the above
threadless over all the measuring period, else an "open tweeter" message will be issued.
The frequency / magnitude setting of the test tone depends on the impedance
characteristics of each specific speaker being used, with or without the tweeter connected
(to be calculated case by case). High-frequency tones (> 10 kHz) or even ultrasonic signals
are recommended for their negligible acoustic impact and also to maximize the impedance
module's ratio between with tweeter-on and tweeter-off.
Figure 28 and 29 shows the load impedance as a function of the peak output voltage and
the relevant diagnostic fields.
It is recommended to keep output voltage always below 8 V (high threshold case) or 4 V
(low threshold case) to avoid the circuit to saturate (causing wrong detection cases).
This feature is disabled if any overload leading to activation of the short-circuit protection
occurs in the process.
20/39
DocID025640 Rev 5
TDA75613LV
Diagnostics functional description
Figure 28. Current detection high: load impedance |Z| vs. output peak voltage
,O AD\Z\/HM
)OUTPEAK M!
,OWCURRENTDETECTIONAREA
/PENLOAD
$OFTHE$"XBYRES
)OUTPEAK M!
)"$
(IGHCURRENTDETECTIONAREA
.ORMALLOAD
$OFTHE$"XBYTES
6OUT 0EAK
'!0'03
Figure 29. Current detection low: load impedance |Z| vs. output peak voltage
,OAD\Z\/HM
)OUTPEAK M!
,OWCURRENTDETECTIONAREA
/PENLOAD
$OFTHE$"XBYRES
)OUTPEAK M!
)"$
(IGHCURRENTDETECTIONAREA
.ORMALLOAD
$OFTHE$"XBYTES
6OUT0EAK
DocID025640 Rev 5
'!0'03
21/39
38
Output DC offset detection
5
TDA75613LV
Output DC offset detection
The TDA75613LV can detect any DC output offset exceeding ±2 V. This inconvenient might
occur as a consequence of initially defective or aged and worn-out input capacitors feeding
a DC component to the inputs, so putting the speakers at risk of overheating.
Every time the power amplifier switches on, the SSR automatically mutes the device in case
of offset.
In play mode, the offset is signalled out on I2C bus.
5.1
Offset detection and mute at start-up, SSR (Speaker Safety
Routine)
TDA75613LV embeds a speaker safety routine in order to protect the speakers in case of
big output offset. This protection mechanism can automatically mute the device within 40 ms
when it detects an offset bigger than 2 V at the output. No external circuit is required for this
feature.
The SSR requires the MCU to turn on the audio power amplifier in a proper sequence. The
MCU should at first turn on the device in MUTE condition and, after a suitable time to
completely power on the device, which is about 1s, send a PLAY command to it and make
sure there is no input signal applied to any of the inputs for at least 100 ms.
See Figure 30. The power amplifier switches on and no input signal is applied. After 1 s the
SVR is fully charged and the output dc voltage is set. The MCU sends the PLAY command
and the offset, on all the channels, is checked. In case the detected offset is null or, anyhow,
lower than 2 V, the power amplifier is kept alive and the audio signal can be applied after 100 ms.
Figure 30. Power on sequence with a detected offset lower than 2 V
22/39
DocID025640 Rev 5
TDA75613LV
Output DC offset detection
Look at the Figure 31. The power amplifier switches on and no input signal is applied. After
1 s the SVR is fully charged and the output dc voltage is set. The MCU sends the PLAY
command and the offset, on all the channels, is checked. If an offset bigger than 2 V is
detected, the power amplifier is switched off within 40 ms.
Figure 31. Power on sequence with a detected offset higher than 2 V
This action is pointed out on the I2C bus, bit DB2-D6. This flag is seen by the microcontroller
which can take necessary actions.
A standby command (hardware or by I2C) can reset the power amplifier
5.2
Offset detection in normal operation
It is a diagnostics function which has to be performed with low-level output AC signal (or
Vin = 0).
The test is run with selectable time duration by microprocessor (from a "start" to a "stop"
command):
START = Last reading operation or setting IB1 - D5 - (OFFSET enable) to 1
STOP = Actual reading operation
Excess offset is signalled out if it is persistent for all the assigned testing time. This feature is
disabled if any overloads leading to activation of the short-circuit protection occurs in the
process.
DocID025640 Rev 5
23/39
38
Multiple faults
6
TDA75613LV
Multiple faults
When more misconnections are simultaneously in place at the audio outputs, it is
guaranteed that at least one of them is initially read out. The others are notified after
successive cycles of I2C reading and faults removal, provided that the diagnostic is enabled.
This is true for both kinds of diagnostic (Turn-On and Permanent).
The table below shows all the couples of double-fault possible. It should be taken into account
that a short circuit with the 4 ohm speaker unconnected is considered as double fault.
Table 6. Double fault table for turn on diagnostic
S. GND
S. Vs
S. Across L.
Open L.
S. GND
S. GND
S. Vs + S. GND
S. GND
S. GND
S. Vs
/
S. Vs
S. Vs
S. Vs
S. Across L.
/
/
S. Across L.
N.A.
Open L.
/
/
/
Open L. (*)
In Permanent Diagnostic the table is the same, with only a difference concerning Open
Load (*), which is not among the recognizable faults. Should an Open Load be present
during the device's normal working, it would be detected at a subsequent Turn-On
Diagnostic cycle (i.e. at the successive Car Radio Turn-On).
6.1
Faults availability
All the results coming from I2C bus, by read operations, are the consequence of
measurements inside a defined period of time. If the fault is stable throughout the whole
period, it will be sent out.
To guarantee always resident functions, every kind of diagnostic cycle (Turn-On,
Permanent, Offset) is activated again after any I2C reading operation. So, when the micro
reads the I2C, a new cycle will be able to start, but the read data will come from the previous
diag. cycle (i.e. The device is in Turn-On state, with a short to GND, then the short is
removed and micro reads I2C. The short to GND is still present in bytes, because it is the
result of the previous cycle. If another I2C reading operation occurs, the bytes do not show
the short). In general to observe a change in Diagnostic bytes, two I2C reading operations
are necessary.
24/39
DocID025640 Rev 5
TDA75613LV
7
Thermal protection
Thermal protection
Thermal protection is implemented through thermal foldback (Figure 32).
Thermal foldback begins limiting the audio input to the amplifier stage as the junction
temperatures rise above the normal operating range. This effectively limits the output power
capability of the device thus reducing the temperature to acceptable levels without totally
interrupting the operation of the device.
The output power will decrease to the point at which thermal equilibrium is reached.
Thermal equilibrium will be reached when the reduction in output power reduces the
dissipated power such that the die temperature falls below the thermal foldback threshold.
Should the device cool, the audio level will increase until a new thermal equilibrium is
reached or the amplifier reaches full power. Thermal foldback will reduce the audio output
level in a linear manner.
Three thermal warnings are available through the I2C bus data. After thermal shut down
threshold is reached, the CD could toggle (as shown in Figure 32) or stay low, depending on
signal level.
Figure 32. Thermal foldback diagram
6OUT
6OUT
4(7!2.
4(7! 2.
4(7!2.
/.
/.
/.
4YP
4YP
4YP
4(3(
34!24
43$
#$OUT
3$
4(3(
%.$
WITHSAMEINPUT
SIGNAL
4J #
4J #
4J #
7.1
'!0'03
Fast muting
The muting time can be shortened to less than 1.5ms by setting (IB2) D5 = 1. This option
can be useful in transient battery situations (i.e. during car engine cranking) to quickly
turnoff the amplifier to avoid any audible effects caused by noise/transients being injected
by preamp stages. The bit must be set back to “0” shortly after the mute transition.
DocID025640 Rev 5
25/39
38
Battery transitions management
TDA75613LV
8
Battery transitions management
8.1
Low voltage operation (“start stop”)
The most recent OEM specifications are requiring automatic stop of car engine at traffic
light, in order to reduce emissions of polluting substances. The TDA75613LV, thanks to its
innovating design, allows to go on playing sound when battery falls down to 6/7V during
such conditions, without producing pop noise. The maximum system power will be reduced
accordingly.
Supported battery cranking curves are shown below, indicating the shape and durations of
allowed battery transitions.
Figure 33. Worst case battery cranking curve sample 1
9EDWW9
9
9
9
9
W
W
W
W W
W
W
WV
*$3*36
V1 = 12 V; V2 = 6 V; V3 = 7 V; V4 = 8 V
t1 = 2 ms; t2 = 50 ms; t3 = 5 ms; t4 = 300 ms; t5 =10 ms; t6 = 1 s; t7 = 2 ms
Figure 34. Worst case battery cranking curve sample 2
9EDWW 9
9
9
9
W
W
W
W
V1 = 12 V; V2 = 6 V; V3 = 7 V
t1 = 2 ms; t2 = 5 ms; t3 = 15 ms; t5 = 1 s; t6 = 50 ms
26/39
DocID025640 Rev 5
W
WV
*$3*36
TDA75613LV
8.2
Battery transitions management
Advanced battery management
In addition to compatibility with low Vbatt, the TDA75613LV is able to sustain upwards fast
battery transitions (like the one showed in Figure 35) without causing unwanted audible
effect, thanks to the innovative circuit topology.
Figure 35. Upwards fast battery transitions diagram
'!0'03
DocID025640 Rev 5
27/39
38
Application suggestion
TDA75613LV
9
Application suggestion
9.1
High efficiency introduction
Thanks to its operating principle, the TDA75613LV obtains a substantial reduction of power
dissipation from traditional class-AB amplifiers without being affected by the massive
radiation effects and complex circuitry normally associated with class-D solutions.
The high efficiency operating principle is based on the use of bridge structures which are
connected by means of a power switch. In particular, as shown in Figure 36, Ch1 is linked to
Ch2, while Ch3 to Ch4. The switch, controlled by a logic circuit which senses the input
signals, is closed at low volumes (output power steadily lower than 2.5 W) and the system
acts like a "single bridge" with double load. In this case, the total power dissipation is a
quarter of a double bridge.
Due to its structure, the highest efficiency level can be reached when symmetrical loads are
applied on channels sharing the same switch.
Figure 36. High efficiency - basic structure
&0
2-
n
)?&
)?2
2EAR
&RONT
6IN&
6IN2
20
&n
)?20
&
CHANNEL
(IGH
IMPEDANCE
2
CHANNEL
#/.42/,
,/')#
"UFFER
'!0'03
When the power demand increases to more than 2.5 W, the system behavior is switched
back to a standard double bridge in order to guarantee the maximum output power, while in
the 6 V start-stop devices the High Efficiency mode is automatically disabled at low VCC
(7.3 V ±0.3 V). No need to re-program it when VCC goes back to normal levels.
In the range 2-4 W (@ VCC = 14.4 V, RL = 4Ω), with the High Efficiency mode, the dissipated
power gets up to 50 % less than the value obtained with the standard mode.
28/39
DocID025640 Rev 5
I2C bus
TDA75613LV
10
I2C bus
10.1
I2C programming/reading sequences
A correct turn on/off sequence with respect to of the diagnostic timings and producing no
audible noises could be as follows (after battery connection):
10.2
TURN-ON: PIN2 > 4.5 V - wait for 10 ms - (STAND-BY OUT + DIAG ENABLE) - wait
for 1s - Muting out (play with no signal) - wait for 100 ms
TURN-OFF: MUTING IN - wait for 50 ms - HW ST-BY IN (ST-BY pin ≤ 1.2 V)
Car Radio Installation: PIN2 > 4.5 V - wait for 10 ms - DIAG ENABLE (write) - wait for
200 ms - I2C read (repeat until all faults disappear).
Address selection and I2C disable
When the ADSEL/I2CDIS pin is left open the I2C bus is disabled and the device can be
controlled by the STBY/MUTE pin.
In this status (no - I2C bus) the CK pin enables the HIGH-EFFICIENCY MODE (0 = STD
MODE; 1 = HE MODE) and the DATA pin sets the gain (0 = 30 dB; 1 = 16 dB).
When the ADSEL/I2CDIS pin is connected to GND the I2C bus is active with address
.
To select the other I2C address a resistor must be connected to ADSEL/I2CDIS pin as
following:
0 < R < 1 kΩ: I2C bus active with address
11 kΩ < R < 21 kΩ: I2C bus active with address
40 kΩ < R < 70 kΩ: I2C bus active with address
R > 120 kΩ: Legacy mode
(x: read/write bit sector)
10.3
I2C bus interface
Data transmission from microprocessor to the TDA75613LV and viceversa takes place
through the 2 wires I2C bus interface, consisting of the two lines SDA and SCL (pull-up
resistors to positive supply voltage must be connected).
10.3.1
Data validity
As shown by Figure 37, the data on the SDA line must be stable during the high period of
the clock. The HIGH and LOW state of the data line can only change when the clock signal
on the SCL line is LOW.
10.3.2
Start and stop conditions
As shown by Figure 38 a start condition is a HIGH to LOW transition of the SDA line while
SCL is HIGH. The stop condition is a LOW to HIGH transition of the SDA line while SCL is
HIGH.
DocID025640 Rev 5
29/39
38
I2C bus
10.3.3
TDA75613LV
Byte format
Every byte transferred to the SDA line must contain 8 bits. Each byte must be followed by an
acknowledge bit. The MSB is transferred first.
10.3.4
Acknowledge
The transmitter* puts a resistive HIGH level on the SDA line during the acknowledge clock
pulse (see Figure 39). The receiver** has to pull-down (LOW) the SDA line during the
acknowledge clock pulse, so that the SDA line is stable LOW during this clock pulse.
* Transmitter
–
master (µP) when it writes an address to the TDA75613LV
–
slave (TDA75613LV) when the µP reads a data byte from TDA75613LV
** Receiver
–
slave (TDA75613LV) when the P writes an address to the TDA75613LV
–
master (µP) when it reads a data byte from TDA75613LV
Figure 37. Data validity on the I2C bus
3$!
3#,
$!4!,).%
34!",%$!4!
6!,)$
#(!.'%
$!4!
!,,/7%$
'!0'03
Figure 38. Timing diagram on the I2C bus
3#,
)#"53
3$!
34!24
34/0
'!0'03
Figure 39. Acknowledge on the I2C bus
3#,
3$!
-3"
!#+./7,%$'-%.4
&2/-2%#%)6%2
34!24
30/39
DocID025640 Rev 5
'!0'03
TDA75613LV
11
Software specifications
Software specifications
All the functions of the TDA75613LV are activated by I2C interface.
The bit 0 of the "ADDRESS BYTE" defines if the next bytes are write instruction (from µP to
TDA75613LV) or read instruction (from TDA75613LV to µP).
Chip address
D7
1
D0
1
0
1
1
(*)
(*)
X
D8 Hex
X = 0 Write to device
X = 1 Read from device
If R/W = 0, the µP sends 2 "Instruction Bytes": IB1 and IB2.
(*) address selector bit, please refer to address selection description on Chapter 10.2.
Table 7. IB1
Bit
Instruction decoding bit
D7
Supply transition mute threshold high (D7 = 1)
Supply transition mute threshold low (D7 = 0)
D6
Diagnostic enable (D6 = 1)
Diagnostic defeat (D6 = 0)
D5
Offset Detection enable (D5 = 1)
Offset Detection defeat (D5 = 0)
D4
Front Channel (CH1, CH3)
Gain = 30 dB (D4 = 0)
Gain = 16 dB (D4 = 1)
D3
Rear Channel (CH2, CH4)
Gain = 30 dB (D3 = 0)
Gain = 16 dB (D3 = 1)
D2
Mute front channels (D2 = 0)
Unmute front channels (D2 = 1)
D1
Mute rear channels (D1 = 0)
Unmute rear channels (D1 = 1)
D0
CD 2% (D0 = 0)
CD 10% (D0 = 1)
DocID025640 Rev 5
31/39
38
Software specifications
TDA75613LV
Table 8. IB2
Bit
Instruction decoding bit
D7
Current detection threshold
High th (D7 = 0)
Low th (D7 =1)
D6
0
D5
Normal muting time (D5 = 0)
Fast muting time (D5 = 1)
D4
Stand-by on - Amplifier not working - (D4 = 0)
Stand-by off - Amplifier working - (D4 = 1)
D3
Power amplifier mode diagnostic (D3 = 0)
Line driver mode diagnostic (D3 = 1)
D2
Current Detection Diagnostic Enabled (D2 =1)
Current Detection Diagnostic Defeat (D2 =0)
D1
Right Channel Power amplifier working in standard mode (D1 = 0)
Power amplifier working in high efficiency mode (D1 = 1)
D0
Left Channel Power amplifier working in standard mode (D0 = 0)
Power amplifier working in high efficiency mode (D0 = 1)
If R/W = 1, the TDA75613LV sends 4 "Diagnostics Bytes" to P: DB1, DB2, DB3 and DB4.
Table 9. DB1
Bit
Instruction decoding bit
D7
Thermal warning 1 active (D7 = 1), Tj = 160 °C (Typ)
-
D6
Diag. cycle not activated or not terminated (D6 = 0)
Diag. cycle terminated (D6 = 1)
-
D5
Channel LF (CH1)
Current detection IB2 (D7) = 0
Output peak current < 250 mA - Open load (D5 = 1)
Output peak current > 500 mA - Normal load (D5 = 0)
Channel LF (CH1)
Current detection IB2 (D7) = 1
Output peak current < 125 mA - Open load (D5 = 1)
Output peak current > 250 mA - Normal load (D5 = 0)
D4
Channel LF (CH1)
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
-
D3
Channel LF (CH1)
Normal load (D3 = 0)
Short load (D3 = 1)
-
D2
Channel LF (CH1)
Turn-on diag.: No open load (D2 = 0)
Open load detection (D2 = 1)
Offset diag.: No output offset (D2 = 0)
Output offset detection (D2 = 1)
-
32/39
DocID025640 Rev 5
TDA75613LV
Software specifications
Table 9. DB1 (continued)
Bit
Instruction decoding bit
D1
Channel LF (CH1)
No short to Vcc (D1 = 0)
Short to Vcc (D1 = 1)
-
D0
Channel LF (CH1)
No short to GND (D1 = 0)
Short to GND (D1 = 1)
-
Table 10. DB2
Bit
Instruction decoding bit
D7
Offset detection not activated (D7 = 0)
Offset detection activated (D7 = 1)
-
D6
Offset detected and automute (SSR) (D6=1)
-
D5
Channel LR (CH2)
Current detection IB2 (D7) = 0
Output peak current < 250 mA - Open load (D5 = 1)
Output peak current > 500 mA - Normal load (D5 = 0)
Channel LR (CH2)
Current detection IB2 (D7) = 1
Output peak current < 125 mA - Open load (D5 = 1)
Output peak current > 250 mA - Normal load (D5 = 0)
D4
Channel LR (CH2)
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
-
D3
Channel LR (CH2)
Normal load (D3 = 0)
Short load (D3 = 1)
-
D2
Channel LR (CH2)
Turn-on diag.: No open load (D2 = 0)
Open load detection (D2 = 1)
Permanent diag.: No output offset (D2 = 0)
Output offset detection (D2 = 1)
-
D1
Channel LR (CH2)
No short to Vcc (D1 = 0)
Short to Vcc (D1 = 1)
-
D0
Channel LR (CH2)
No short to GND (D1 = 0)
Short to GND (D1 = 1)
-
DocID025640 Rev 5
33/39
38
Software specifications
TDA75613LV
Table 11. DB3
Bit
Instruction decoding bit
D7
Standby status (= IB2 - D4)
-
D6
Diagnostic status (= IB1 - D6)
-
D5
Channel RF (CH3)
Current detection IB2 (D7) = 0
Output peak current < 250 mA - Open load (D5 = 1)
Output peak current > 500 mA - Normal load (D5 = 0)
Channel RF (CH3)
Current detection IB2 (D7) = 1
Output peak current < 125 mA - Open load (D5 = 1)
Output peak current > 250 mA - Normal load (D5 = 0)
D4
Channel RF (CH3)
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
-
D3
Channel RF (CH3)
Normal load (D3 = 0)
Short load (D3 = 1)
-
D2
Channel RF (CH3)
Turn-on diag.: No open load (D2 = 0)
Open load detection (D2 = 1)
Permanent diag.: No output offset (D2 = 0)
Output offset detection (D2 = 1)
-
D1
Channel RF (CH3)
No short to Vcc (D1 = 0)
Short to Vcc (D1 = 1)
-
D0
Channel RF (CH3)
No short to GND (D1 = 0)
Short to GND (D1 = 1)
-
34/39
DocID025640 Rev 5
TDA75613LV
Software specifications
Table 12. DB4
Bit
Instruction decoding bit
D7
Thermal warning 2 active (D7 = 1), Tj = 145 °C (Typ)
-
D6
Thermal warning 3 active (D6 = 1) Tj = 125 °C (Typ)
-
D5
Channel RR (CH4)
Current detection IB2 (D7) = 0
Output peak current < 250 mA - Open load (D5 = 1)
Output peak current > 500 mA - Normal load (D5 = 0)
Channel RR (CH4)
Current detection IB2 (D7) = 1
Output peak current < 125 mA - Open load (D5 = 1)
Output peak current > 250 mA - Normal load (D5 = 0)
D4
Channel RR (CH4)
Turn-on diagnostic (D4 = 0)
Permanent diagnostic (D4 = 1)
-
D3
Channel R (CH4)
R Normal load (D3 = 0)
Short load (D3 = 1)
-
D2
Channel RR (CH4)
Turn-on diag.: No open load (D2 = 0)
Open load detection (D2 = 1)
Permanent diag.: No output offset (D2 = 0)
Output offset detection (D2 = 1)
-
D1
Channel RR (CH4)
No short to Vcc (D1 = 0)
Short to Vcc (D1 = 1)
-
D0
Channel RR (CH4)
No short to GND (D1 = 0)
Short to GND (D1 = 1)
-
DocID025640 Rev 5
35/39
38
Examples of bytes sequence
12
TDA75613LV
Examples of bytes sequence
1 - Turn-On diagnostic - Write operation
Start
Address byte with D0 = 0
ACK
IB1 with D6 = 1
ACK
IB2
ACK
STOP
2 - Turn-On diagnostic - Read operation
Start Address byte with D0 = 1 ACK DB1
ACK DB2 ACK DB3 ACK DB4 ACK STOP
The delay from 1 to 2 can be selected by software, starting from 1ms
3a - Turn-On of the power amplifier with 30 dB gain, mute on, diagnostic defeat, CD = 2%
.
Start
Address byte with D0 = 0
ACK
IB1
ACK
X0000000
IB2
ACK STOP
XXX1XX11
3b - Turn-Off of the power amplifier
Start
Address byte with D0 = 0
ACK
IB1
ACK
X0XXXXXX
IB2
ACK STOP
XXX0XXXX
4 - Offset detection procedure enable
Start
Address byte with D0 = 0
ACK
IB1
XX1XX11X
ACK
IB2
ACK STOP
XXX1XXXX
5 - Offset detection procedure stop and reading operation (the results are valid only for the
offset detection bits (D2 of the bytes DB1, DB2, DB3, DB4)
.
Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP
36/39
The purpose of this test is to check if a D.C. offset (2V typ.) is present on the outputs,
produced by input capacitor with anomalous leakage current or humidity between pins.
The delay from 4 to 5 can be selected by software, starting from 1ms
DocID025640 Rev 5
TDA75613LV
Package information
In order to meet environmental requirements, ST offers these devices in different grades of
ECOPACK® packages, depending on their level of environmental compliance. ECOPACK®
specifications, grade definitions and product status are available at: www.st.com.
ECOPACK® is an ST trademark.
Figure 40. Flexiwatt27 (vertical) mechanical data and package dimensions
$)-
-).
!
"
#
$
%
&
'
'
(
(
(
(
,
,
,
,
,
,
-
.
/
2
2
2
2
2
6
6
6
6
MM
490
-!8
-).
INCH
490
-!8
/54,).%!.$
-%#(!.)#!,$!4!
7\S
7\S
7\S
7\S
&LEXIWATTVERTICAL
DAM
BARPROTUSIONNOTINCLUDED
MOLDINGPROTUSIONINCLUDED
6
#
"
6
(
(
6
!
(
/
(
2
,
2
6
2
,
.
2
,
13
Package information
,
,
6
6
2
$
2
,
0IN
2
2
%
'
'
&
&,%8-%
-
-
'!0'03
DocID025640 Rev 5
37/39
38
Revision history
14
TDA75613LV
Revision history
Table 13. Document revision history
38/39
Date
Revision
Changes
05-Dec-2013
1
Initial release.
10-Feb-2014
2
Updated Section 10.1: I2C programming/reading sequences on
page 29.
28-Apr-2014
3
Updated Section 10.2: Address selection and I2C disable on
page 29.
07-Jul-2014
4
Modified Figure 2: Application circuit on page 6.
Added Section 3.4: Electrical characteristic curves on page 14.
22-Sep-2014
5
Updated Section 10.1: I2C programming/reading sequences on
page 29.
DocID025640 Rev 5
TDA75613LV
IMPORTANT NOTICE – PLEASE READ CAREFULLY
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and
improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on
ST products before placing orders. ST products are sold pursuant to ST’s terms and conditions of sale in place at the time of order
acknowledgement.
Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or
the design of Purchasers’ products.
No license, express or implied, to any intellectual property right is granted by ST herein.
Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.
ST and the ST logo are trademarks of ST. All other product or service names are the property of their respective owners.
Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
© 2014 STMicroelectronics – All rights reserved
DocID025640 Rev 5
39/39
39