ED-P

ED-P

  • 厂商:

    SYSTEMSENSOR

  • 封装:

  • 描述:

    ED-P - Intelligent Photoelectric Smoke Detectors - Systemsensor advanced ideas.

  • 数据手册
  • 价格&库存
ED-P 数据手册
INSTALLATION AND MAINTENANCE INSTRUCTIONS ED-P, ED-PT, and ED-DP Intelligent Photoelectric Smoke Detectors Specifications Normal Operating Voltage: Standby Current: Alarm Current: Humidity Range: Temperature Range: Heat Detector: Height: Diameter: Weight: 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com 15 to 30 VDC 481µA max. @ 24 VDC (continuous broadcasts) 2 mA max. @ 24 VDC (LEDs on) 10% to 93% Relative Humidity, noncondensing 32°F to 120°F (0°C to 49°C ); ED-P, ED-DP 32°F to 100°F (0°C to 38°C); ED-PT 135°F Fixed Temperature Electronic Thermistor 2.1 inches (51 mm) installed in EBF Base 6.1 inches (155 mm) installed in EBF Base 4.1 inches (104 mm) installed in EB Base 5.2 oz. (147 g) Before Installing This detector must be installed in compliance with the con- apart. For specific information regarding detector spacing, trol panel system installation manual. The installation must placement, and special applications, refer to NFPA 72 or meet the requirements of the Authority Having Jurisdiction the System Smoke Detector Applications Guide, available (AHJ). Detectors offer maximum performance when from System Sensor. installed in compliance with the National Fire Protection Duct Applications: ED-P and ED-PT are listed for use in Association (NFPA); see NFPA 72. ducts. See Duct Applications Guide A05-1004-XX for details on pendant mount applications. General Description Models ED-P, ED-PT and ED-DP are intelligent photoelectric, spot-type smoke detectors utilizing sensing chambers Wiring Guide that are designed to respond rapidly to a broad range of All wiring must be installed in compliance with the fires. The sensing chamber employs features that minimize National Electrical Code, applicable local codes, and any the effects of settled dust on performance. Model ED-PT special requirements of the Authority Having Jurisdiction uses a thermistor based, 135°F heat detection circuit in (AHJ). Proper wire gauges should be used. The installation addition to the photoelectric sensing chamber. ED-DP is wires should be color-coded to limit wiring mistakes and designed for use inside the ED-DPR duct housing only. ED- simplify system troubleshooting. Improper connections will prevent a system from responding properly in the event of DP should not be used in open area applications. a fire. The detector is designed with tri-color LEDs to indicate detector status. The detector can be programmed to make 1. Wire the detector base (supplied separately) per the wiring diagram, see Figure 1. the LEDs blink or be steady green, amber or red. The detector remote output can be configured to follow the LED or 2. Install the detector into the base. Push the detector into the base while turning it clockwise to secure it in be independently controlled. A remote LED annunciator is place. available as an accessory (RA400Z). 3. Set the desired address using the IR configuration tool The ED-P, ED-PT and ED-DP require compatible address- (model no. EA–CT). able communications to function properly. Connect these Note: Maximum range for the EA–CT is 30 ft. (9 m). 4. Test the detector(s) as described in the TESTING section detectors to listed-compatible control panels only. of this manual. Spacing System Sensor recommends spacing detectors in compliance with NFPA 72. In low air flow applications with smooth ceilings, the detectors should be spaced 30 feet D800-02-00 1 I56-2026-02R Figure 1. Wiring diagram: CAUTION: Do not loop wire under terminal 1 or 3. Break wire run to provide supervision of connections. OPTIONAL REMOTE ANNUNCIATOR – + LISTED COMPATIBLE CONTROL PANEL 2 3 2 3 + 4 4 1 – – + OPTIONAL RETURN LOOP C0113-00 CAUTION Dust covers provide limited protection against airborne dust particles during shipping. Dust covers must be removed before the detectors can sense smoke. Remove detectors prior to heavy remodeling or construction. Tamper-Resistance Models ED-P and ED-PT include a tamper-resistant capability that prevents their removal from the base without the use of a tool. Refer to the base manual for details on making use of this capability. Testing Before testing, notify the proper authorities that the system is undergoing maintenance, and will temporarily be out of service. Disable the system to prevent unwanted alarms. All detectors must be tested after installation and periodically thereafter. Testing methods must satisfy the Authority Having Jurisdiction (AHJ). Detectors offer maximum performance when tested and maintained in compliance with NFPA 72. B. Smoke Entry: Smoke entry testing should be performed immediately following the functional test. The functional test initiates an approximately 5 minute period when the detector’s signal processing software routines are not active. Failure to do so will introduce a time delay before the detector alarms. Home Safeguard Model 25S Smoke Detector Tester can be used to verify smoke entry into the sensing chamber and the corresponding alarm response. Aim the aerosol can at the detector and spray for one to two seconds from a distance of two to four feet until the panel alarms. Another method is to use the GEMINI model 501 aerosol generator for smoke entry testing. Set the generator to represent 4%/ft. to 5%/ft. obscuration as described in the GEMINI 501 manual. Using the bowl shaped applicator, apply aerosol until the panel alarms. C. Direct Heat (ED-PT only): A hair dryer, heat gun, or test apparatus designed for this purpose should be used to test the thermistors. Direct the heat toward either of the two thermistors, using care The detector can be tested in the following ways: to avoid damaging the plastic housing. The detector will A. Functional: reset only after it has had sufficient time to cool. Make This detector can be functionally tested by using the sure that both thermistors are tested individually. EA–CT. Following the instructions, initiate the detector test sequence. The detector will then send a test alarm A detector that fails any of these tests should be cleaned message to the panel. Refer to the control panel techni- as described under CLEANING, and retested. If the cal documentation for further information. detector fails after cleaning, it must be replaced. When testing is complete, restore the system to normal operation and notify the proper authorities that the system is back in operation. D800-02-00 2 1 I56-2026-02R Cleaning Before removing the detector, notify the proper authorities that the smoke detector system is undergoing maintenance and will be temporarily out of service. Disable the zone or system undergoing maintenance to prevent unwanted alarms. Figure 2. Detector assembly: Sensor Cover 1. Remove the detector to be cleaned from the system. 2. Remove the detector cover by pressing firmly on each Cover of the four removal tabs that hold the cover in place. Removal Tabs 3. Vacuum the screen carefully without removing it. If further cleaning is required continue with Step 4, oth- Optional erwise skip to Step 7. Thermistors 4. Remove the chamber cover/screen assembly by pull- (ED-PT) ing it straight out. 5. Use a vacuum cleaner or clean compressed air to remove dust and debris from the sensing chamber. 6. Reinstall the chamber cover/screen assembly by sliding the edge over the sensing chamber. Turn until it is firmly in place. 7. Replace the cover using the LEDs to align the cover and then gently pushing it until it locks into place. Make sure that the thermistors do not become bent under the cover on ED-PT models. 8. Reinstall the detector. 9. Test the detector as described in TESTING. 10. Reconnect disabled circuits. 11. Notify the proper authorities that the system is back on line. Special Note Regarding Smoke Detector Guards Smoke detectors are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. Sensing Chamber Cover and Screen Sensing Chamber C0348-00 D800-02-00 3 I56-2026-02R Please refer to insert for the Limitations of Fire Alarm Systems Three-Year Limited Warranty System Sensor warrants its enclosed smoke detector to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for this smoke detector. No agent, representative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the repair or replacement of any part of the smoke detector which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Returns Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: his equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These T limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. D800-02-00 4 © 2004 System Sensor I56-2026-02R

很抱歉,暂时无法提供与“ED-P”相匹配的价格&库存,您可以联系我们找货

免费人工找货
EDP3036
  •  国内价格
  • 1+7.66803
  • 30+7.39802
  • 100+6.85802
  • 500+6.31802
  • 1000+6.04802

库存:2798

EDP3020
  •  国内价格
  • 1+5.8
  • 30+5.6
  • 100+5.2
  • 500+4.8
  • 1000+4.6

库存:20

CRCW04021K00DHEDP
  •  国内价格
  • 1+2.38328

库存:10