0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GSOT05L-V-G-08

GSOT05L-V-G-08

  • 厂商:

    VISHAY

  • 封装:

  • 描述:

    GSOT05L-V-G-08 - Single-Line ESD-Protection Diode in SOT-23 - Vishay Siliconix

  • 数据手册
  • 价格&库存
GSOT05L-V-G-08 数据手册
GSOT05L-V Vishay Semiconductors Single-Line ESD-Protection Diode in SOT-23 FEATURES 3 • Single-line ESD-protection device • ESD-immunity acc. IEC 61000-4-2 ± 30 kV contact discharge ± 30 kV air discharge 1 2 20421 20512 • Space saving SOT-23 package 1 • AEC-Q101 qualified • e3 - Sn • Compliant to RoHS directive 2002/95/EC and in accordance to WEEE 2002/96/EC MARKING (example only) XX XX 20357 YYY YYY = type code (see table below) X = date code ORDERING INFORMATION DEVICE NAME GSOT05L-V ENVIRONMENTAL STATUS Standard Green ORDERING CODE GSOT05L-V-GS08 GSOT05L-V-G-08 TAPED UNITS PER REEL (8 mm TAPE ON 7" REEL) 3000 MINIMUM ORDER QUANTITY 15 000 PACKAGE DATA DEVICE NAME GSOT05L-V PACKAGE NAME SOT-23 TYPE CODE 05L 5LG ENVIRONMENTAL STATUS Standard Green WEIGHT 8.8 mg 8.1 mg MOLDING COMPOUND FLAMMABILITY RATING UL 94 V-0 MOISTURE SENSITIVITY LEVEL SOLDERING CONDITIONS MSL level 1 260 °C/10 s at terminals (according J-STD-020) ABSOLUTE MAXIMUM RATINGS GSOT05L-V PARAMETER Peak pulse current Peak pulse power ESD immunity Operating temperature Storage temperature TEST CONDITIONS Pin 3 to 1 acc. IEC 61000-4-5, 8/20 µs/single shot Pin 3 to 1 acc. IEC 61000-4-5, 8/20 µs/single shot Contact discharge acc. IEC 61000-4-2; 10 pulses Air discharge acc. IEC 61000-4-2; 10 pulses Junction temperature SYMBOL IPPM PPP VESD TJ TSTG VALUE 13 156 ± 30 ± 30 - 40 to + 150 - 55 to + 150 UNIT A W kV kV °C °C ** Please see document “Vishay Material Category Policy”: www.vishay.com/doc?99902 Document Number: 85181 Rev. 1.2, 01-Jul-10 For technical questions, contact: ESDprotection@vishay.com www.vishay.com 1 GSOT05L-V Vishay Semiconductors Single-Line ESD-Protection Diode in SOT-23 BiAs-MODE (bidirectional asymmetrical protection mode) With the GSOT05L-V one signal- or data-lines (L1) can be protected against voltage transients. With pin 1 connected to ground and pin 3 connected to a signal- or data-line which has to be protected. As long as the voltage level on the data- or signal-line is between 0 V (ground level) and the specified maximum reverse working voltage (VRWM) the protection diode between data line and ground offers a high isolation to the ground line. The protection device behaves like an open switch. As soon as any positive transient voltage signal exceeds the break through voltage level of the protection diode, the diode becomes conductive and shorts the transient current to ground. Now the protection device behaves like a closed switch. The clamping voltage (VC) is defined by the breakthrough voltage (VBR) level plus the voltage drop at the series impedance (resistance and inductance) of the protection device. Any negative transient signal will be clamped accordingly. The negative transient current is flowing in the forward direction of the protection diode. The low forward voltage (VF) clamps the negative transient close to the ground level. Due to the different clamping levels in forward and reverse direction the GSOT05L-V clamping behaviour is bidirectional and asymmetrical (BiAs). L1 3 1 2 BiAs Ground 20422 ELECTRICAL CHARACTERISTICS GSOT05L-V PARAMETER Protection paths Reverse stand off voltage Reverse current Reverse breakdown voltage Reverse clamping voltage Forward clamping voltage Capacitance TEST CONDITIONS/REMARKS Number of lines which can be protected at IR = 1 µA at VR = 5.5 V at IR = 1 mA at IPP = 1 A at IPP = IPPM = 13 A at IPP = 1 A at IPP = IPPM = 13 A at VR = 0 V; f = 1 MHz at VR = 2.5 V; f = 1 MHz SYMBOL Nlines VRWM IR VBR VC VF CD MIN. 5.5 6 TYP. 6.1 6.75 6.9 10 1 2.6 100 60 MAX. 1 7 1 9 12 1.3 3 120 UNIT lines V µA V V V V V pF pF Note • Ratings at 25 °C, ambient temperature unless otherwise specified. BiAs mode (between pin 3 to 1). TYPICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified) 120 % Rise time = 0.7 ns to 1 ns 100 % 80 % 80 % 60 % 53 % 8 µs to 100 % Discharge Current IESD 100 % IPPM 60 % 20 µs to 50 % 40 % 20 % 0% 0 10 20 30 40 40 % 27 % 20 % 0% - 10 0 10 20 30 40 50 60 70 80 90 100 20557 Time (ns) 20548 Time (µs) Fig. 1 - ESD Discharge Current Wave Form acc. IEC 61000-4-2 (330 Ω/150 pF) Fig. 2 - 8/20 µs Peak Pulse Current Wave Form acc. IEC 61000-4-5 www.vishay.com 2 For technical questions, contact: ESDprotection@vishay.com Document Number: 85181 Rev. 1.2, 01-Jul-10 GSOT05L-V Single-Line ESD-Protection Diode in Vishay Semiconductors SOT-23 120 f = 1MHz 100 12 10 8 positive surge 80 6 CD (pF) VC (V) 60 40 4 2 0 Measured acc. IEC 61000-4-5 (8/20 µs - wave form) VC Pin 3 to 1 negative surge 0 2 4 6 8 10 12 14 16 20 0 0 21926 -2 -4 1 2 3 4 5 6 21929 VR (V) IPP (A) Fig. 3 - Typical Capacitance CD vs. Reverse Voltage VR Fig. 6 - Typical Peak Clamping Voltage VC vs. Peak Pulse Current IPP 102 101 Pin 1 to 3 1 10-1 10-2 10-3 10-4 10-5 10-6 0.3 21927 80 60 40 acc. IEC 61000-4-2 + 8 kV contact discharge VC-ESD (V) IF (mA) 20 0 - 20 - 40 - 60 - 10 0 21930 Pin 3 to 1 pos. discharge 0.4 0.5 0.6 0.7 0.8 0.9 10 20 30 40 50 60 70 80 90 V F (V ) t (ns) Fig. 4 - Typical Forward Current IF vs. Forward Voltage VF Fig. 7 - Typical Clamping Performance at + 8 kV Contact Discharge (acc. IEC 61000-4-2) 8 7 6 60 40 20 acc. IEC 61000-4-2 - 8 kV contact discharge VC-ESD (V) 5 Pin 3 to 1 VR (V) 0 - 20 - 40 - 60 - 80 - 10 0 Pin 3 to 1 neg. discharge 4 3 2 1 0 0.01 0.1 1 10 100 1000 10 000 21928 10 20 30 40 50 60 70 80 90 IR (µA) 21931 t (ns) Fig. 5 - Typical Reverse Voltage VR vs. Reverse Current IR Fig. 8 - Typical Clamping Performance at - 8 kV Contact Discharge (acc. IEC 61000-4-2) Document Number: 85181 Rev. 1.2, 01-Jul-10 For technical questions, contact: ESDprotection@vishay.com www.vishay.com 3 GSOT05L-V Vishay Semiconductors Single-Line ESD-Protection Diode in SOT-23 250 200 150 100 acc. IEC 61000-4-2 contact discharge VC-ESD (V) 50 0 - 50 - 100 - 150 - 200 - 250 0 5 10 15 20 25 30 Pin 3 to 1 VC-ESD 21932 VESD (kV) Fig. 9 - Typical Peak Clamping Voltage at ESD Contact Discharge (acc. IEC 61000-4-2) PACKAGE DIMENSIONS in millimeters (inches): SOT-23 1.15 (0.045) 2.6 (0.102) 2.35 (0.093) 0.7 (0.028) 0.95 (0.037) 0.9 (0.035) 0.9 (0.035) 3.1 (0.122) 2.8 (0.110) 0.550 ref. (0.022 ref.) 0.1 (0.004) max. 0.175 (0.007) 0.098 (0.004) 0.2 (0.008) 0.45 (0.018) 0.35 (0.014) 0.45 (0.018) 0.35 (0.014) 0.3 (0.012) 0.45 (0.018) 1.43 (0.056) 0.35 (0.014) 1.20 (0.047) Foot print recommendation: 1 (0.039) 0.9 (0.035) 1 (0.039) 0.9 (0.035) Document no.: 6.541-5014.01-4 Rev. 8 - Date: 23.Sept.2009 17418 2 (0.079) 0.95 (0.037) www.vishay.com 4 For technical questions, contact: ESDprotection@vishay.com Document Number: 85181 Rev. 1.2, 01-Jul-10 0° t 0.5 (0.020) o8 ° Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 11-Mar-11 www.vishay.com 1
GSOT05L-V-G-08 价格&库存

很抱歉,暂时无法提供与“GSOT05L-V-G-08”相匹配的价格&库存,您可以联系我们找货

免费人工找货