0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TPB-1200-E

TPB-1200-E

  • 厂商:

    EATON(伊顿)

  • 封装:

    -

  • 描述:

    TELECOMFUSE1200AMP

  • 数据手册
  • 价格&库存
TPB-1200-E 数据手册
Telpower® DC Power Protection Systems Telpower® DC Power Distribution Fuses Bussmann® TPB 170 Volts DC, 1000-2000 Amps Catalog Symbol: TPB DC Power Distribution Fuses Current-Limiting Ampere Rating: 1000 to 2000A Voltage Rating: 170Vdc Interrupting Rating: 100,000A Agency Information: UL Recognized, Guide JFHR2, File E91958 Catalog Number TPB-1000-E TPB-1000-M TPB-1200-E TPB-1200-M TPB-1600-E TPB-1600-M TPB-2000-E TPB-2000-M Amp 1000 1000 1200 1200 1600 1600 2000 2000 Qty. 1 1 1 1 1 1 1 1 Weight* Lbs. 4.25 4.25 4.25 4.25 4.25 4.25 4.25 4.25 Kg. 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 * Weight per carton. General Information: • Telpower® BLUE™ label fuses are specifically designed for dc power distribution systems. • Minimum I2t short-circuit let-through levels. • Current-limiting capability. • Complete system coordination capability. Mounting Alignment TPB fuses are not meant as fixing isolators. Excessive push, pull and tensional forces due to misalignments between fuse and bus bars, which might occur like in the example shown below, should be avoided. If possible the fuse installation should be made starting with a fixed input busbar. The fuse should then be mounted to the input busbar, followed by the output busbar. Finally, the output busbar should be rigidly fixed within the system equipment. TABLE A PART NUMBER TPB-1000-E TPB-1200-E TPB-1600-E TPB-2000-E TPB-1000-M TPB-1200-M TPB-1600-M TPB-2000-M AMP TIGHTENING TORQUE THREADS RATING * ** 1000 1200 ENGLISH 29 lbf-ft 14.7 lbf-ft 1600 3/8-24 x .590DEEP 2000 1000 1200 METRIC 40N-m 20N-m 1600 M10 x 15mm DEEP 2000 Bussmann recommends a calibrated torque wrench with a tolerance of max. ±4%. *) Ungreased thread **) Thread greased with Rhodorsil Paste 4 (Rhone-Poulenc) etc. Tightening torque and contact pressure TPB fuses are electro-mechanical devices. Their function is very much dependent of the quality of the contact between the fuse and the connecting bus bars. A poor thermal connection can result in overheating of the fuse and reduced lifetime. The number one rule is therefore to observe the right tightening torque when mounting the fuse. See Table A. Fuses with flush end contacts For all types of flush end fuses Bussmann recommends (screw in) studs. The studs must be tightened carefully applying a torque of 5-8Nm (3.7 -5.9 lbf-ft). As a general rule the tightening torque for the nuts relates to the dimension of the threaded hole in the fuse contact. See Table A for the recommended nut tightening torques. The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 3-26-03 SB03087 Look for Telpower® BLUE™ fuses exclusively from Cooper Bussmann. Form No. TPB Page 1 of 2 Data Sheet: 5025 Telpower® DC Power Protection Systems Telpower® DC Power Distribution Fuses Bussmann® TPB 170 Volts DC, 1000-2000 Amps Time-Current Characteristic Curve–Average Melt 3-26-03 SB03087 Look for Telpower® BLUE™ fuses exclusively from Cooper Bussmann. Form No. TPB Page 2 of 2 Data Sheet: 5025
TPB-1200-E 价格&库存

很抱歉,暂时无法提供与“TPB-1200-E”相匹配的价格&库存,您可以联系我们找货

免费人工找货