0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
655

655

  • 厂商:

    TPI(TPI 公司)

  • 封装:

    -

  • 描述:

    LAMP INCAND T3.25 GLSS WEDGE 28V

  • 数据手册
  • 价格&库存
655 数据手册
Tuffman Pressure Meter TPI 635 / 645 / 655 Visit TPI, The Value Leader at: www.tpi-thevalueleader.com Table of Contents Page 3 Introduction & Product Description Page 4 Safety Considerations Page 5 Technical Data & International Symbols Page 6 Features & Benefits Page 7 Pressure Conversion Table Page 8 Step by Step Procedures Page 9 Accessories & Specifications Page 10 Maintenance Page 11 Trouble Shooting Guide EC declaration of conformity Page 12 Warranty Statement page 1 Introduction Congratulations! Thank you for purchasing TPI brand products. This meter is easy to use and is built to last. It is backed by a 3 year limited warranty. Please remember to return your product warranty registration card. Product Description The TPI 600 Tuffman series is a hand held range Of pressure meters and can be summarized as follows. TPI 635 5 PSI pressure range TPI 645 30 PSI pressure range TPI655 100 PSI pressure range All of these models are dual input differential pressure meters with 7 selectable scales to choose from: mbar, kPa, PSI, inHg. mmHg,inH20, and mH20. page 2 Safety Considerations WARNING: Please follow the manufacture's test procedure whenever possible. Make sure the pressure to be measured is not outside the range of the TPI 635/645/655 meter. General Guidelines ALWAYS • Test the pressure meter before use to ensure it is operating properly • Ensure that the connecting hose you are using is free from kinks or splits • Double check all connections before testing NEVER • Connect the instrument to an unknown pressure source if the source is twice the working pressure of the instrument the sensor will be damaged and may cause injury to the user • Tamper with the instrument or attempt to modify it in any way. Otherwise accident and injury may occur and the warranty be comes void. page 3 Technical Data Controls TPI 635/645/655 ON OFF ZERO == MAX/MIN HOLD UNITS page 4 Switches instrument "ON" for use Switches instrument "OFF" after use Automatically "zero's" the instrument Smoothing function to stabilize rapidly changing readings Enables user to recall & display both the maximum and minimum pressure recorded since the function was selected. Press button once to activate, twice to read minimum and three times to read the maximum. To cancel the function press and the hold the "MAXIMIN" button Maintains the reading on the LCD display Selects 7 units of measure kPa, PSI, inHg, mmHg, inH20, mH 20, mbar Features & Benefils Auto rangingProvides high resolution & accuracy at low pressures where it is needed Auto Power Off- Powers off after 30 minutes to conserve battery life. Trim ModeSmoothing function to stabilize erratic readings. It displays the average value of 4 values previously measured. Zero functionProvides immediate push-button zeroing for Speed and accuracy. Record Max/Min- Enables long term testing of pressure systems for leaks HoldEnables the user to freeze the display reading, when working in cramped working conditions, when the display is not visible. UnitsChange the display value in anyone of the following engineering units. kPa, PSI, inHg, mmHg, inH20, mH20 and mbar. page 5 Pressure Conversion Table Atmos Atmos 1 mbar 1013.25 in H20 406.8 inHg 29.9213 PSI 14.6959 mH20 10.3323 mmHg kPa page 6 760 101.325 mbar inHg inH20 9.86923 x 10-4 3.34207 X 10-2 2.45832 X 10-3 2.95301 x 10-2 1 7.35561 X 10-2 1 0.401463 33.8638 13.5951 1.45038 x 10-2 0.491153 1.01972 x 10-2 0.345315 0.750064 0.1 25.4 3.38638 2.49089 1 3.61273 X 10-2 1.86833 2.54 X 10-2 0.249089 PSI mmHg mH20 kPa 6.8046 X 10-2 1.31579 X 10-3 9.67841 X 10-3 9.86923 X 10-3 2.036 3.937 X 10-2 2.89591 0.295301 39.3701 4.01463 1.42233 0.145038 73.5561 7.50064 1 0.101972 9.80665 1 68.9476 27.68 1 51.715 0.70307 6.89476 1.33322 0.534 1.934 X 10-2 1 1.35951 X10-2 0.133322 98.0665 10 Step by Step Procedures • Press the "ON" key and the LCD display will be activated if it does not read 0.00 proceed as follows • Press the "zero" key and the display should read zero. if not repeat until it does • Connect pressure meter to installation or equipment to be tested using appropriate hose connection in accordance with the manufactures instructions • The pressure reading will appear on the display. To activate the backlight in poor light conditions press the "ON' key at any time • If the reading is erratic or changing activate the smoothing unction by pressing the" =" key • To freeze a reading in awkward or cramped working spaces press the "Hold" key • To record maximum & minimum pressures when establishing pressure decay or carrying out gas line soundness testing press the "MAXIMIN" key • To convert the displayed pressure reading to another engineering unit depress the "Unit" key anytime and scroll through to the desired units of pressure. page 7 Accessories & Specifications Standard Accessories 9V ALKALINE battery Replacement tubing t/4" 00 x 28"(L) Optional Accessories Replacement tubing 1/4' 00 x 28" T Fitting Large Zippered Case 9V lithium battery Part No. A009A A601 Part No. A605 A904 U9VL Features Model 635 645 655 Range 5 PSI 30 PSI 100 PSI Accuracy ±O.2'% of full scale +3 digits Over Pressure 14.5 psi (1000 mbar) 58.0 psi (4000 mbar) 145 psi (10 bar) Power Supply 9V Relative Humidity 0% to 80% (a· to + 40°C) Operating Temp. 32° to 104°F (D' to +40°C) Storage Temp. 14° to 122°F (-10"10 + 50'C) Auto Power Off After 30 minutes Trim Mode Yes Zero Adjust Yes Push Button Data Hold Yes Record Yes Max/Min page 8 Maintenance Battery Replacement The 635/645/655 will display a iBATi symb 01 when the internal 9V battery needs replacement. Replace battery as follows: 1. Ensure instrument is switched off 2. Loosen the cross head screw on the battery compartment cover 3. Remove battery compartment cover 4. Remove old battery 5. Replace with new battery 9V NEDA 1604 or equivalent 6. Reassemble the instrument in reverse order from above 7. RE-fit the cross head screw being sure not to over tighten Cleaning Use a mild detergent and a slightly damp cloth to clean the surfaces of the instrument. page 9 Trouble Shooting Guide Problem Pro Unit does not zero Unit still does not zero iBati appears on the display bable Cause Zero button has not been operated If reading is greater than 0.05 and constantly fluctuation return to local service centre Replace battery immediately 9V NEDA 15050cequivalent EC Declaration 01 Conformity This is to certify that model 634/645/655 conform to the protection requirements of the council directive 89/336/EEC, in the approximation of laws of the member states relating to Electromagnetic compatibility by application of the following standards EN50081-1 1992 Emissions Standard EN50082-1 1992 Immunity Standard To ensure conformity with these standards, this instrument must be operated in accordance with the instructions and specifications given in this manual. page 10 Warranty Statement 3 Year Limited Warranty This TPI product is warranted to the purchaser against defect in materials and workmanship for 3 years from the date of purchase. Covered by TPI: Repair parts and labour; or replacement of the product at the option of TPI. Normal transportation charges to the purchaser are also covered. Not covered by TPI: Damage to the product which are the result of abuse, improper use or maintenance are not covered. Any other expense, consequential damages, incidental expenses including damages to property is not covered. Transportation expense to the company are not covered. To obtain warranty performance: include with the product your name, address, phone number, written description of the problem and proof of purchase date. Carefully package and return to the address printed below. Test Products International, Ltd. 342 Bronte Sl. South Unit #9 Miltoll, Ontario L9T 5B7 Canada 905-693-8558 Fax: 905 -693-0888 e-mail: inlo@lpicanada.com page 11 Test Products International, Inc Headquarters 9615 SW AIlen Blvd. Beaverton, OR 97005 USA 503-520-91971 Fax: 503-520-1225 e-mail: inlo@tpi-lhevalueleader.com

很抱歉,暂时无法提供与“655”相匹配的价格&库存,您可以联系我们找货

免费人工找货