0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VP9MU2G7228JBHSB

VP9MU2G7228JBHSB

  • 厂商:

    VIKINGTECHNOLOGY

  • 封装:

    288-UDIMM

  • 描述:

    MODULE DDR4 SDRAM 16GB 288UDIMM

  • 数据手册
  • 价格&库存
VP9MU2G7228JBHSB 数据手册
DDR4 (PC4) ECC UDIMM VP9MUxx72x8xxx The Viking DDR4 UDIMM memory module offers lower operating voltages, higher module densities and faster speed categories than the prior DDR3 generation. JEDEC DDR4 (JESD79-4) has been defined to provide higher performance, with improved reliability and reduced power, thereby representing a significant achievement relative to previous DRAM memory technologies. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 1 of 42 vikingtechnology.com REVISION HISTORY Revision A Release Date 3/19/17 Description of Change Initial release modified from PS9MUxx72x8xxx_C. Add 2666 timings and PN Datasheet PS9MUxx72x8xxx_VP Revision A Checked By (Full Name) 3/13/2017 Viking Technology Page 2 of 42 vikingtechnology.com Legal Information Legal Information Copyright© 2017 Sanmina Corporation. All rights reserved. The information in this document is proprietary and confidential to Sanmina Corporation. No part of this document may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from Sanmina. Sanmina reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of Sanmina to provide notification of such revision or change. Sanmina provides this documentation without warranty, term or condition of any kind, either expressed or implied, including, but not limited to, expressed and implied warranties of merchantability, fitness for a particular purpose, and noninfringement. While the information contained herein is believed to be accurate, such information is preliminary, and should not be relied upon for accuracy or completeness, and no representations or warranties of accuracy or completeness are made. In no event will Sanmina be liable for damages arising directly or indirectly from any use of or reliance upon the information contained in this document. Sanmina may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time. Sanmina, Viking Technology, Viking Modular Solutions, and the Viking logo are trademarks of Sanmina Corporation. Other company, product or service names mentioned herein may be trademarks or service marks of their respective owners. STATEMENT OF COMPLIANCE Viking Technology, Sanmina Corporation ("Viking") shall use commercially reasonable efforts to provide components, parts, materials, products and processes to Customer that do not contain: (i) lead, mercury, hexavalent chromium, polybrominated biphenyls (PBB) and polybrominated diphenyl ethers (PBDE) above 0.1% by weight in homogeneous material or (ii) cadmium above 0.01% by weight of homogeneous material, except as provided in any exemption(s) from RoHS requirements (including the most current version of the "Annex" to Directive 2002/95/EC of 27 January, 2003), as codified in the specific laws of the EU member countries. Viking strives to obtain appropriate contractual protections from its suppliers in connection with the RoHS Directives. All printed circuit boards (PCBs) have a flammability rating of UL94V-0. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 3 of 42 vikingtechnology.com 288 pin Ordering Information and Module Configuration Viking Part Number VP9MU127228HBHyz VP9MU127228HBJyz1 VP9MU127228HBKyz1 VP9MU1G7228HBHyz VP9MU1G7228HBJyz1 VP9MU1G7228HBKyz1 VP9MU1G7228JBHyz VP9MU1G7228JBJyz1 VP9MU1G7228JBKyz1 VP9MU2G7228JBHyz VP9MU2G7228JBJyz1 VP9MU2G7228JBKyz1 Voltage Capacity 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V 1.2V 4GB 4GB 4GB 8GB 8GB 8GB 8GB 8GB 8GB 16GB 16GB 16GB Module Configuration 512Mx72 512Mx72 512Mx72 1Gx72 1Gx72 1Gx72 1Gx72 1Gx72 1Gx72 2Gx72 2Gx72 2Gx72 Device Configuration 512Mx8 (9) 512Mx8 (9) 512Mx8 (9) 512Mx8 (18) 512Mx8 (18) 512Mx8 (18) 1024Mx8 (9) 1024Mx8 (9) 1024Mx8 (9) 1024Mx8 (18) 1024Mx8 (18) 1024Mx8 (18) Device Package 4Gb FBGA 4Gb FBGA 4Gb FBGA 4Gb FBGA 4Gb FBGA 4Gb FBGA 8Gb FBGA 8Gb FBGA 8Gb FBGA 8Gb FBGA 8Gb FBGA 8Gb FBGA DIMM Ranks Speed 1 1 1 2 2 2 1 1 1 2 2 2 PC4-17000 PC4-19200 PC4-21300 PC4-17000 PC4-19200 PC4-21300 PC4-17000 PC4-19200 PC4-21300 PC4-17000 PC4-19200 PC4-21300 CAS Latency CL15 (15-15-15) CL17 (17-17-17) CL19 (19-19-19) CL15 (15-15-15) CL17 (17-17-17) CL19 (19-19-19) CL15 (15-15-15) CL17 (17-17-17) CL19 (19-19-19) CL15 (15-15-15) CL17 (17-17-17) CL19 (19-19-19) Notes:  The lowercase letters y and z are wildcard characters that indicate DRAM vendor and die revisions and /or for customer specific locked BOMs. Refer to the Viking part number coversheet for details. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 4 of 42 vikingtechnology.com Features  JEDEC Standard Power Supply o PC4: VDD = VDDQ = 1.2V± 5% (1.14V-1.26V) o External VPP = 2.5 Volt +10%, -5% o VDDSPD = 2.5V± 10% (2.25-2.75V)  288 pin Dual-In-Line Memory Module  Edge finger connector ramp zone to reduce insertion force  Point-to-Point topology to reduce loading  Pseudo-open drain (POD12) DQ lines  Internally generated VrefDQ  ECC recovery from command and parity errors  On-chip CA Parity detection for the command/address bus  Programmable CAS Latency: 13,15,16  Programmable CAS Write Latency (CWL).  Programmable Additive Latency (Posted CAS)  Per DRAM addressability is supported  Data Bus Inversion support for x8 devices  Selectable Fixed burst chop (BC4) of 4 and burst length (BL8) of 8 on-the-fly (OTF) via the mode register set (MRS)  8n prefetch with 2 or 4 selectable bank groups: 16 banks (4 bank groups x 4 banks per bank group)  Separate activation, read, write, refresh operations for each bank group  7 mode registers  Dynamic On-Die-Termination (ODT) and ODT Park for improved signal integrity.  Self Refresh and several Power Down Modes  DLL-off mode for power savings  System Level Timing Calibration Support via Write Leveling and Multi Purpose Register (MPR) Read Pattern  Serial Presence Detect with EEPROM  Two On-DIMM Thermal Sensors  Asynchronous Reset  Bidirectional Differentially Buffered Data Strobes(DQS)  UDIMM dimensions per JEDEC MO-309 maximum limits  RoHS Compliant DDR4 SPEED BIN Nomenclature Module Standard DDR4-14900 DDR4-17000 1 DDR4-19200 1 DDR4-21300 1 DDR4-25600 SDRAM Standard DDR4-1866 DDR4-2133 DDR4-2400 DDR4-2667 DDR4-3200 Clock 933 MHz 1066 MHz 1200 MHz 1333 MHz 1600 MHz Notes: 1. Contact Viking for availability date DDR4 Timing Summary MT/s tCK (ns) CAS Latency (tCK) tRCD (ns) tRP (ns) tRAS (ns) tRC (ns) CL-tRCDtRP DDR4-1866 1.071 13 13.92 13.92 34 47.92 13-13-13 DDR4-2133 0.93 15 14.06 14.06 33 47.05 15-15-15 DDR4-2400 0.83 17 14.16 14.16 32 46.16 17-17-17 DDR4-2666 0.75 22 14.25 14.25 32 46.25 19-19-19 Notes:  CL = CAS Latency, tRCD = Activate –to-Command Time, tRP = Precharge Time. Refer to Speed Bin tables for details. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 5 of 42 vikingtechnology.com Addressing 4GB(1Rx8) 512Mx8 DRAM 8GB(1Rx8) 1024Mx8 DRAM 16GB(2Rx8) 1024Mx8 DRAM 4 4 4 BG Address BG0~BG1 BG0~BG1 BG0~BG1 Bank Address in a BG BA0~BA1 BA0~BA1 BA0~BA1 Row Address A0~A14 64K:A0~A15 64K:A0~A15 Column Address A0~ A9 A0~ A9 A0~ A9 512B 512B 512B 4K 8K 8K # of Bank Groups Bank Address Page size Refresh Count Note:  Micron datasheet specified 512B / 1KB as page size with “Die revision dependant”.  In Hynix and Samsung Datasheet specfies 512B for x4 Device. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 6 of 42 vikingtechnology.com DDR4 288-pin UDIMM Pin Wiring Assignments/Configurations Pin# Description Pin# Description Pin# Description Pin# Description Pin# Description Pin# Description 196 DQS8_c 102 DQ38 246 VSS 1 12V3, NC 145 12V3, NC 52 DQS17_c, TDQS17_c 2 VSS 146 VREFCA 53 VSS 197 DQS8_t 103 VSS 247 DQ39 3 DQ4 147 VSS 54 CB6, NC 198 VSS 104 DQ34 248 VSS 4 VSS 148 DQ5 55 VSS 199 CB7, NC 105 VSS 249 DQ35 5 DQ0 149 VSS 56 CB2, NC 200 VSS 106 DQ44 250 VSS 6 150 DQ1 57 VSS 201 CB3, NC 107 VSS 251 DQ45 151 VSS 58 RESET_n 202 VSS 108 DQ40 252 VSS 8 VSS DQS9_t, DM0_n, DBI0_n, TDQS9_t DQS9_c, TDQS9_c 152 DQS0_c 59 VDD 203 CKE1 109 253 DQ41 9 VSS 153 DQS0_t 60 CKE0 204 VDD 110 254 VSS 10 DQ6 154 VSS 61 VDD 205 RFU 111 VSS DQS14_t, DM5_n, DBI5_n, TDQS14_t DQS14_c, TDQS14_c 255 DQS5_c 11 VSS 155 DQ7 62 ACT_n 206 VDD 112 VSS 256 DQS5_t 12 DQ2 156 VSS 63 BG0 207 BG1 113 DQ46 257 VSS 13 VSS 157 DQ3 64 VDD 208 ALERT_n 114 VSS 258 DQ47 14 DQ12 158 VSS 65 A12 209 VDD 115 DQ42 259 VSS 15 VSS 159 DQ13 66 A9 210 A11 116 VSS 260 DQ43 16 DQ8 160 VSS 67 VDD 211 A7 117 DQ52 261 VSS 17 161 DQ9 68 A8 212 VDD 118 VSS 262 DQ53 162 VSS 69 A6 213 A5 119 DQ48 263 VSS 19 VSS DQS10_t, DM1_n, DBI1_n, TDQS10_t DQS10_c, TDQS10_c 163 DQS1_c 70 VDD 214 A4 120 264 DQ49 20 VSS 164 DQS1_t 71 A3 215 VDD 121 265 VSS 21 DQ14 165 VSS 72 A1 216 A2 122 VSS DQS15_t, DM6_n, DBI6_n, TDQS15_t DQS15_c, TDQS15_c 266 DQS6_c 22 VSS 166 DQ15 73 VDD 217 VDD 123 VSS 267 DQS6_t 23 DQ10 167 VSS 74 CK0_t 218 CK1_t 124 DQ54 268 VSS 24 VSS 168 DQ11 75 CK0_c 219 CK1_c 125 VSS 269 DQ55 25 DQ20 169 VSS 76 VDD 220 VDD 126 DQ50 270 VSS 26 VSS 170 DQ21 77 VTT 221 VTT 127 VSS 271 DQ51 27 DQ16 171 VSS 78 EVENT_n 222 PARITY 128 DQ60 272 VSS 28 172 DQ17 79 A0 223 VDD 129 VSS 273 DQ61 29 VSS DQS11_t, DM2_n, DBI2_n, TDQS11_t 173 VSS 80 VDD 224 BA1 130 DQ56 274 VSS 30 DQS11_c, 174 DQS2_c 81 BA0 225 A10_AP 131 VSS 275 DQ57 7 18 Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 7 of 42 vikingtechnology.com Pin# Description Pin# Description Pin# Description Pin# Description Pin# Description Pin# Description 276 VSS 277 DQS7_c TDQS11_c 31 VSS 175 DQS2_t 82 RAS_n/A16 226 VDD 132 32 DQ22 176 VSS 83 VDD 227 RFU 133 DQS16_t, DM7_n, DBI7_n, TDQS16_t DQS16_c, TDQS16_c 33 VSS 177 DQ23 84 S0_n 228 WE_n/A14 134 VSS 278 DQS7_t 34 DQ18 178 VSS 85 VDD 229 VDD 135 DQ62 279 VSS 35 VSS 179 DQ19 86 CAS_n/A15 230 SAVE_n, NC2 136 VSS 280 DQ63 36 DQ28 180 VSS 87 ODT0 231 VDD 137 DQ58 281 VSS 37 VSS 181 DQ29 88 VDD 232 A13 138 VSS 282 DQ59 38 DQ24 182 VSS 89 S1_n 233 VDD 139 SA0 283 VSS 39 183 DQ25 90 VDD 234 A17, NC 140 SA1 284 VDDSPD 184 VSS 91 ODT1 235 C[2], NC 141 SCL 285 SDA 41 VSS DQS12_t, DM3_n, DBI3_n, TDQS12_t DQS12_c, TDQS12_c 185 DQS3_c 92 VDD 236 VDD 142 VPP 286 VPP 42 VSS 186 DQS3_t 93 S2_n, C[0] 237 S3_n, C[1] 143 VPP 287 VPP 43 DQ30 187 VSS 94 VSS 238 SA2, RFU 144 RFU 288 VPP 44 VSS 188 DQ31 95 DQ36 239 VSS 45 DQ26 189 VSS 96 VSS 240 DQ37 46 VSS 190 DQ27 97 DQ32 241 VSS 47 CB4, NC 191 VSS 98 242 DQ33 48 VSS 192 CB5, NC 99 243 VSS 49 CB0, NC 193 VSS 100 VSS DQS13_t, DM4_n, DBI4_n, TDQS13_t DQS13_c, TDQS13_c 244 DQS4_c 50 VSS DQS17_t, DM8_n, DBI8_n, TDQS17_t 194 CB1, NC 101 VSS 245 DQS4_t 40 51 195 VSS Notes: 1. VPP is 2.5V DC 2. Pin 230 is defined as NC for UDIMMs, RDIMMs and LRDIMMs. Pin 230 is defined as SAVE_n (ADR) for NVDIMMs. 3. Pins 1 and 145 are defined as NC for UDIMMs, RDIMMs and LRRDIMMs. Pins 1 and 145 are defined as 12V for Hybrid /NVDIMM DIMMs. 4. A15 needed for 4GBit DRAM, A16 needed for 8GBit DRAM, A17 needed for 16GBit DRAM 5. Only x8 and x16 DRAM support Data Mask (DM) and Data Bus Inversion (DBI). Only x8 DRAM support TDQS 6. DM, DBI & TDQS functions are supported with dedicated one pin labeled as DM_n/DBI_n/TDQS_t. The pin is bi-directional pin for DRAM. The DM_n/DBI _n pin is Active Low as DDR4 supports VDDQ reference termination. TDQS function does not drive actual level on the pin. DM, DBI & TDQS functions are programmable through DRAM Mode Register (MR). The MR bit location is bit A11 in MR1 and bit A12:A10 in MR5 . Write operation: Either DM or DBI function can be enabled but both functions cannot be enabled simultaneously. When both DM and DBI functions are disabled, DRAM turns off its input receiver and does not expect any valid logic level. Read operation: Only DBI function applies. When DBI function is disabled, DRAM turns off its output driver and does not drive any valid logic level. TDQS function: When TDQS function is enabled, DM & DBI functions are not supported. When TDQS function is disabled, When enabled, the same termination resistance function is applied to the TDQS_t/TDQS_c pins that is applied to DQS_t/DQS_c pins. DM, DBI & TDQS functions are described in more detail on x8 based datasheets Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 8 of 42 vikingtechnology.com PIN FUNCTION DESCRIPTION Pin Name Description Pin Name Description A0-A17' Register address input SCL BA0, BA1 Register bank select input SDA BG0, BG1 Register bank group select input SA0-SA2 RAS_n Register row address strobe input PAR I2C serial bus clock for SPD/TS and register I2C serial bus data line for SPD/TS and register I2C slave address select for SPD/TS and register Register parity input CAS_n3 Register column address strobe input VDD SDRAM core power supply VREFCA SDRAM command/address reference supply VSS Power supply return (ground) 2 WE_n4 CS0_n, CS1_n, CS2_n, CS3_n CKE0, CKE1 Register write enable input DIMM Rank Select Lines input Register clock enable lines input ACT_n Register on-die termination control lines input Register input for activate input VDDSPD Serial SPDrTS positive power supply DQ0-DQ63 DIMM memory data bus ALERT_n Register ALERT_n output CB0-CB7 DIMM ECC check bits Data Buffer data strobes (positive line of differential pair) Data Buffer data strobes (negative line of differential pair) Vpp DRAM Activation Power Supply ODT0, ODT1 TDQS9_t-TDQS17_t TDQS9_c- TDQS17_c RESET_n EVENT_n CK0_t, CK1_t CK0_c, CK1_c Register clock input (positive line of differential pair) Register clocks input (negative line of differential pair) Vtt RFU Set Register and SDRAMs to a Known state SPD signals a thermal event has occurred. SDRAM I/O termination supply Reserved for future use Notes: 1. Address A17 is only valid for 16GBit DRAM 2. RAS_n is a multiplexed function with A16. (A16 needed for 8GBit DRAM) 3. CAS_n is a multiplexed function with A15. (A15 needed for 4GBit DRAM) 4. WE_n is a multiplexed function with A14 Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 9 of 42 vikingtechnology.com Input/Output Functional Descriptions Symbol Type CK_t, CK_c Input CKE0, (CKE1) Input CS0_n, (CS1_n) Input C0,C1,C2 Input ODT0, (ODT1) Input ACT_n Input RAS_n/A16, CAS_n/A15, WE_n/A14 Input DM_n/DBI_n/ TDQS_t, (DMU_n/DBIU_n), (DML_n/DBIL_n) Input/ Output BG0 - BG1 Input Function Clock: CK_t and CK_c are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CK_t and negative edge of CK_c. Clock Enable: CKE HIGH activates, and CKE Low deactivates, internal clock signals and device input buffers and output drivers. Taking CKE Low provides Precharge Power-Down and Self-Refresh operation (all banks idle), or Active Power-Down (row Active in any bank). CKE is asynchronous for Self-Refresh exit. After VREFCA and VREFDQ have become stable during the power on and initialization sequence, they must be maintained during all operations (including Self-Refresh). CKE must be maintained high throughout read and write accesses. Input buffers, excluding CK, CK_c, ODT and CKE, are disabled during powerdown. Input buffers, excluding CKE, are disabled during Self-Refresh. Chip Select: All commands are masked when CS_n is registered HIGH. CS_n provides for external Rank selection on systems with multiple Ranks. CS_n is considered part of the command code. Chip ID: Chip ID is only used for 3DS for 2,4,8high stack via TSV to select each slice of stacked component. Chip ID is considered part of the command code. On Die Termination: ODT (registered HIGH) enables termination resistance internal to the DDR4 SDRAM. When enabled, ODT is only applied to each DQ, DQS_t, DQS_c and DM_n/DBI_n/TDQS_t,NU/TDQS_c (When TDQS is enabled via Mode Register A11=1 in MR1) signal for x8 configurations. For x16 configuration ODT is applied to each DQ, DQSU_c, DQSU_t, DQSL_t, DQSL_c, DMU_n, and DML_n signal. The ODT pin will be ignored if MR1 is programmed to disable RTT_NOM. Activation Command Input: ACT_n defines the Activation command being entered along with CS_n. The input into RAS_n/A16, CAS_n/A15 and WE_n/A14 will be considered as Row Address A16, A15 and A14. Command Inputs RAS_n/A16, CAS_n/A15 and WE_n/A14 (along with CS_n) define the command being entered. Those pins have multi function. For example, for activation with ACT_n Low, those are Addressing like A16,A15 and A14 but for non-activation command with ACT_n High, those are Command pins for Read, Write and other command defined in command truth table. Input Data Mask and Data Bus Inversion: DM_n is an input mask signal for write data. Input data is masked when DM_n is sampled LOW coincident with that input data during a Write access. DM_n is sampled on both edges of DQS. DM is muxed with DBI function by Mode Register A10,A11,A12 setting in MR5. For x8 device, the function of DM or TDQS is enabled by Mode Register A11 setting in MR1. DBI_n is an input/output identifying whether to store/output the true or inverted data. If DBI_n is LOW, the data will be stored/output after inversion inside the DDR4 SDRAM and not inverted if DBI_n is HIGH. TDQS is only supported in x8. Bank Group Inputs: BG0 - BG1 define to which bank group an Active, Read, Write or Precharge command is being applied. BG0 also determines which mode register is to be accessed during a MRS cycle. x4/8 have BG0 and BG1 but x16 has only BG0. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 10 of 42 vikingtechnology.com Input/Output Functional Descriptions (cont.) Symbol Type Function BA0 - BA1 Input Bank Address Inputs: BA0 - BA1 define to which bank an Active, Read, Write or Precharge command is being applied. Bank address also determines if the mode register or extended mode register is to be accessed during a MRS cycle. Input Address Inputs: Provided the row address for ACTIVATE Commands and the column address for Read/Write commands th select one location out of the memory array in the respective bank. (A10/AP, A12/BC_n, RAS_n/A16, CAS_n/A15 and WE_n/A14 have additional functions, see other rows. The address inputs also provide the op-code during Mode Register Set commands. A17 is only defined for the x4 configuration. A10 / AP Input Auto-precharge: A10 is sampled during Read/Write commands to determine whether Autoprecharge should be performed to the accessed bank after the Read/Write operation. (HIGH: Autoprecharge; LOW: no Autoprecharge).A10 is sampled during a Precharge command to determine whether the Precharge applies to one bank (A10 LOW) or all banks (A10 HIGH). If only one bank is to be precharged, the bank is selected by bank addresses. A12 / BC_n Input Burst Chop: A12 / BC_n is sampled during Read and Write commands to determine if burst chop (on-the-fly) will be performed. (HIGH, no burst chop; LOW: burst chopped). See command truth table for details. RESET_n Input Active Low Asynchronous Reset: Reset is active when RESET_n is LOW, and inactive when RESET_n is HIGH. RESET_n must be HIGH during normal operation. RESET_n is a CMOS rail to rail signal with DC high and low at 80% and 20% of V DD. DQ Input / Output Data Input/ Output: Bi-directional data bus. If CRC is enabled via Mode register then CRC code is added at the end of Data Burst. Any DQ from DQ0~DQ3 may indicate the internal Vref level during test via Mode Register Setting MR4 A4=High. Refer to vendor specific datasheets to determine which DQ is used. CB Input / Output Check Bit Input/ Output: Bi-directional ECC portion of data bus for x72 configurations Input / Output Data Strobe: output with read data, input with write data. Edge-aligned with read data, centered in write data. For x16, DQSL corresponds to the data on DQL0-DQL7; DQSU corresponds to the data on DQU0-DQU7. The data strobe DQS_t, DQSL_t, and DQSU_t are paired with differential signals DQS_c, DQSL_c, and DQSU_c, respectively, to provide differential pair signaling to the system during reads and writes. DDR4 SDRAM supports differential data strobe only and does not support single-ended. A0 - A17 DQS_t, DQS_c, DQSU_t, DQSU_c, DQSL_t, DQSL_c Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 11 of 42 vikingtechnology.com Input/Output Functional Descriptions (cont.) Symbol ALERT_n TEN Type Function Output Alert: It has multi functions such as CRC error flag, Command and Address Parity error flag. If there is error in CRC, then Alert_n goes LOW for the period time interval and goes back HIGH. IF there is error in Command Address Parity Check, then Alert_n goes LOW for relatively long period until on going DRAM internal recovery transaction to complete. Input Boundary Scan Mode Enable: Required on x16 devices and optional input on x4/x8 with densities equal to or greater than 8Gb. HIGH in this pin will enable boundary scan operation along with other pins. It is a CMOS rail to rail signal with DC high and low at 80% and 20% of VDD. NC No Connect: No internal electrical connection is present. VDDQ Supply DQ Power Supply: 1.2 V +/- 0.06 V VSSQ Supply DQ Ground VDD Supply Power Supply: 1.2 V +/- 0.06 V VSS Supply Ground Vpp Supply DRAM Activation Power Supply: 2.5V (2.375V min , 2.75 max) VREFCA Supply Reference voltage for CA ZQ Supply Reference Pin for ZQ calibration Note: The input only pins (BG0-BG-1, BA0-BA1, A0-A17, ACT_n, RAS_n,/A16, CAS_n/A15, WE_n/A14, CS_n, CKE, ODT, and RESET_n) do not supply termination. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 12 of 42 vikingtechnology.com MECHANICAL OUTLINE 4.1mm 3.90 mm Max 133.50 mm Max 31.4 mm Max 1.50 mm Max Notes: 1. All dimensions in mm (inches) 2. Tolerance is +/- 0.0127, unless otherwise stated. 3. Refer to JEDEC Standard Mechanical Outline MO-309 for other details 4. DDR4 PCB is higher and thicker then DDR3 and the gold finger pins may have a ramp zone for easy insertion into DIMM Sockets Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 13 of 42 vikingtechnology.com Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 14 of 42 vikingtechnology.com FUNCTIONAL BLOCK DIAGRAM Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 15 of 42 vikingtechnology.com Notes:  The ZQ ball on each DDR4 component is connected to an external 240Ω ±1% resistor that is tied to ground. It is used for the calibration of the component’s ODT and output driver. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 16 of 42 vikingtechnology.com DQ Internal Vref Specifications Parameter Vref Max operating point Range 1 Vref Min operating point Range 1 Vref Max operating point Range 2 Vref Min operating point Range 2 Vref Stepsize Vref Set Tolerance Vref Step Time Vref VaIid tolerance Symbol Min Typ Max Unit NOTE Vref_max_R1 - - 92% VDDQ 1, 11 Vref_min_R1 60% - - VDDQ 1,11 Vref_max_R2 - - 77% VDDQ 1, 11 0.65% 0.00% 0.00% 0.00% 0.80% 1.63% 0.15% 150 60 0.15% VDDQ VDDQ VDDQ VDDQ ns ns VDDQ 1,11 2 3,4,6 3,5,7 9 8 10 Vref_min_R2 Vref_step Vref_set_tol 45% 0.50% -1 .625% -0.15% Vref_time-long Vref_time-Short Vref_val_tol -0.15% Notes: 1. JESD8-24 specifies Vref to be 70% of VDDQ. Vref DC voltage referenced to VDDQ_DC. VDDQ_DC is 1.2V 2. Vref stepsize increment/decrement range. Vref at DC level. 3. Vref_new = Vref_old+n*Vref_step; n=number of step; if increment use “+”; If decrement use “-” 4. The minimum value of Vref setting tolerance=Vref_new-1.625%*VDDQ. The maximum value of Vref setting tolerance=Vref_new+1.625%*VDDQ. For n>4 5. The maximum value of Vref setting tolerance=Vref_new-0.15%*VDDQ. The maximum value of Vref setting tolerance=Vref_new+0.15%*VDDQ. For n&4 tbd 6. Measured by recording the min and max values of the Vref output over the range, drawing a straight line between those points and comparing all other Vref output settings to that line 7. Measured by recording the min and max values of the Vref output across 4 consecutive steps(n=4), drawing a straight line between those points and comparing all other Vref output settings to that line 8. Time from MRS command to increment of decrement one step size for Vref 9. Time from MRS command to increment of decrement more than one step size up to full range of Vref 10. Only applicable for DRAM component level test/characterization purpose. Not applicable for normal mode of operation. Vref valid is to qualify the step times which will be characterized at the component level. 11. DRAM range1 or 2 set by MRS bit MR6,A6. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 17 of 42 vikingtechnology.com OVERVIEW OF DDR4 UDIMM MODULE OPERATION The DDR4 architecture is generally a point-to-point topology with a dedicated channel design. The highest system performance levels can be achieved with DDR4-2133 and beyond, when the system is configured as 1 UDIMM Per Channel (1DPC). DDR4 has more features than DDR3 with a pseudo-open drain (POD12) 1.2v I/O for the data channel, trained Vref, bank groups and write CRC. The POD12 interface only applies to the data channel. The address command channel behave like DDR3 using mid-point termination and mid-point Vref. The new bank group interleaving feature in DDR4 maximizes data transfer bandwidth. DDR4 DRAM use pseudo-open drain (POD12) 1.2v drivers with Vdd terminations on DQ lines to increase data rates; unlike DDR3 DRAM that uses stub-series terminated logic drivers, The DRAM addressing scheme in DDR4 is organized into bank groups, Side A and Side B. The host DDR4 memory controller interleaves (multiplexes) among the bank groups to achieve high data rates. DDR4 architecture is a 8n prefetch with bank groups, including the use of two or four selectable bank groups. This will permit the DDR4 memory devices to have separate activation, read, write or refresh operations simultaneously underway in each of the unique bank groups to improve overall memory efficiency and bandwidth, especially when small memory granularities are used. The data written to the UDIMM is read back the same way. However when writing to the internal registers with a "load mode" operation, a specific address is required. This requires the controller to know if the rank is mirrored or not. There is a bit assignment in the SPD that indicates whether the module has been designed with a mirrored feature or not. DDR4 offers ECC recovery from command and parity errors to prevent the host system from crashing. The use of CRC parity is an optional feature on address command and data; (Error command blocking when parity enabled and post CA parity. If the UDIMM does not support CRC, the values of 0x00 will fill the CRC table. The new CA parity feature on the command/address bus provides a low-cost method of verifying the integrity of command and address transfers over a link, for all operations. Some of the main attributes of DDR4 memory are: 1) Internally generated VrefDQ and Calibration. VrefDQ is supplied by the DRAM internally. VrefCA is supplied by the board. 2) The ACT_n activate pin replaces RAS#, CAS#, and WE# commands, 3) Alert_n for error checking 4) Bank group Interleaving 5) Improved training modes upon power-up 5) Nominal and dynamic ODT: Improvements to the ODT protocol and a new Park Mode allow for a nominal termination and dynamic write termination without having to drive the ODT pin 6) DQ bus geardown mode for 2667 Mhz data rates and beyond 7) External VPP at 2.5V (for wordline boost) 8) 1.2V VDD power with power-saving features that include MPSM Maximum Power Savings Mode, Low Power Auto Self Refresh, Temperature Controlled Refresh, Fine Granularity Refresh, and CMD/ADDT latency. DLL off mode. Important Note: Longer boot-up times may be experienced in certain situations due to controller initiated functions such as VrefDQ calibration, write leveling and other trainings for the UDIMM. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 18 of 42 vikingtechnology.com DDR4 MODE REGISTERS A12 A11 MR0 RFU MR1 Qoff TDQS MR2 Write CRC RFU MR3 MPR Read Format MR4 MR5 MR6 Write Preamble Read DBI Enable A10 A9 Write Recovery and RTP A7 Test Mode Write Leveling Rtt_NOM Rtt_WR RFU Write CMD Latency with CRC and DM Read Preamble Read Preamble Training Enable Self Refresh Abort Enable Write DBI Enable Data Mask Enable Parity Persiste nt Error tCCD_L and tDLLK Timing MR7 A8 DLL Reset RFU A6 A5 A4 CAS Latency CL RFU RFU Auto Self Refresh A3 A2 Burst Type CL Additive Latency CWL A1 Burst Length BL RFU Temp Sensor PerDRAM Addr Mode Gear down MPR Enable CS-to-Address Latency CAL RFU VrefDQ Monitor Enable Temp Refresh Mode Temp. Refresh Range Rtt_PARK ODT input in Power Down Panty Error Status CRC Error Clear VrefDQ Training enable VrefDQ Training Range DLL Enable Ron Fine Granularity Refresh RFU A0 RFU RFU MPR Page Max Power Down Enable RFU CMD Address Parity Latency VretDQ Training Value Manufacturing use only to program the RCD Notes:  Refer to JEDEC documentation for detail of the control/status bits Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 19 of 42 vikingtechnology.com DC OPERATING CONDITIONS AND CHARACTERISTICS ABSOLUTE MAXIMUM RATINGS Parameter Symbol Value Unit Notes Voltage on any pin relative to GND Vin, Vout -0.3 ~ 1.5 V 1, Voltage on VDD supply relative to GND VDD -0.3 ~ 1.5 V 1,3 Voltage on VDDQ supply relative to GND VDDQ -0.3 ~ 1.5 V 1,3 Voltage on VPP supply relative to GND VPP -0.3 ~ 3.0 V 4 1,5 Module operating temperature (ambient) Topr 0 ~ 55 C 1,2 Storage temperature Tstg -55 ~ +100 C Notes: 1. Permanent device damage may occur if ‘ABSOLUTE MAXIMUM RATINGS’ are exceeded. Functional operation should be restricted to recommended operating condition. Exposure to higher than recommended voltage for extended periods of time could affect device reliability. Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability 2. Storage Temperature is the case surface temperature on the center/top side of the DRAM. For the measurement conditions, please refer to JESD51- 2 standard. 3. VDD and VDDQ must be within 300 mV of each other at all times and VREFCA must be not greater than 0.6 x VDDQ, When VDD and VDDQ are less than 500 mV; VREF may be equal to or less than 300 mV 4. VPP must be equal or greater than VDD/VDDQ at all times 5. Refer to JEDEC JC451 specification DRAM Component Operating Temperature Range Symbol Toper Parameter Rating Units Note Normal Operating Temperature Range 0 to 85 °C 1,2 Extended Temperature Range 85 to 95 °C 1,3 Notes: 1. Operating Temperature TOPER is the case surface temperature on the center / top side of the DRAM. For measurement conditions, please refer to the JEDEC document JESD51-2. 2. The Normal Temperature Range specifies the temperatures where all DRAM specifications will be supported. During operation, the DRAM case temperature must be maintained between 0 - 85oC under all operating conditions. 3. Some applications require operation of the DRAM in the Extended Temperature Range between 85oC and 95oC case temperature. Full specifications are guaranteed in this range, but the following additional conditions apply: a) Refresh commands must be doubled in frequency, therefore reducing the Refresh interval tREFI to 3.9 µs. It is also possible to specify a component with 1X refresh (tREFI to 7.8µs) in the Extended Temperature Range. Please refer to the DIMM SPD for option availability. b) If Self-Refresh operation is required in the Extended Temperature Range, then it is mandatory to either use the Manual SelfRefresh mode with Extended Temperature Range capability (MR2 A6 = 0b and MR2 A7 = 1b) or enable the optional Auto SelfRefresh mode (MR2 A6 = 1b and MR2 A7 = 0b). DDR4 SDRAMs support Auto Self-Refresh and in Extended Temperature Range and please refer to component datasheet and/or the DIMM SPD for tREFI requirements in the Extended Temperature Range tREFI by Device Density Parameter Average periodic refresh interval Symbol 2Gb 4Gb 8Gb 16Gb Units 0°C ≤ Tcase ≤ 85°C 7.8 7.8 7.8 7.8 μs 85°C ≤ Tcase ≤ 95°C 3.9 3.9 3.9 3.9 μs tREFI Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 20 of 42 vikingtechnology.com AC & DC Operating Conditions DC OPERATING CONDITIONS AND CHARACTERISTICS (POD12) Symbol VDD Rating Parameter Supply Voltage VDD: PC4:1.2V±5%, VPP Supply Voltage for Output. Values in () are at 70% of VDD 2.5V +10%, -5% VDDSPD @2.5V VDDQ Units Notes Min Typ Max 1.14 1.2 1.26 v 1,2,3 1.14 (0.798) 1.2 (0.84) 1.26 (0.882) v 1 2.375 2.5 2.75 v 3 2.2 2.5 2.8 v Notes: 1. JESD8-24 specifies Vref to be 70% of VDDQ. Under all conditions VDDQ must be less than or equal to VDD. 2. VDDQ tracks with VDD. AC parameters are measured with VDD and VDDQ tied together. 3. DC bandwidth is limited to 20MHz., 4. PODI2 1.2 V Pseudo Open Drain Interface has a VDDQ value of 1.2V but the reference voltage allows PODI2 to be used with other VDDQ values. POD12 signals have pull-up-only parallel input termination and have an asymmetric output drive impedance. For example, if the output drivers were using a 60 ohm pull-up drive impedance then the pull-down drivers would be expected to produce a 40 ohm pull-down drive impedance. PODI2 does not explicitly call for series termination resistors, so it is suitable for point-to-point as well as multi-drop stub environments which may require some additional termination. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 21 of 42 vikingtechnology.com DC CHARACTERISTICS, IDD CURRENTS IDD DEFINITIONS Symbol Parameter IDD0 One bank ACTIVATE-PRECHARGE current IPP0 IDD1 IDD2N IDD2NT IDD2P IDD2Q One bank ACTIVATE-PRECHARGE, Word Line Boost, IPP current One bank ACTIVATE-READ-PRECHARGE current Precharge standby current Precharge standby ODT current Precharge power-down current Precharge quiet standby current IDD3N IPP3N IDD3P IDD4R IDDQ4R IDD4W Active standby current Active standby IPP current Active power-down current Burst read current Burst read IDDQ current Burst write current IDD5B IPP5B IDD6N IDD6E IDD6R IDD6A Burst refresh current (1x REF) Burst refresh IPP current (1 x REF) Self refresh current: Normal temperature range (0°C to +85°C) Self refresh current: Extended temperature range (0°C to +95°C) Self refresh current: Reduced temperature range (0°C to +45°C) Auto self refresh current (25°C) IDD6A Auto self refresh current (45°C) IDD6A Auto self refresh current (75°C) IDD7 Bank interleave read current IPP7 Bank interleave read IPP current IDD8 Maximum power-down current Notes: 1) DDR4 IDD and IDDQ specs include the same DDR3 IDD and IDDQ specs with these exceptions: a. IDD2P0 and IDD2P1 are replaced with a single IDD2P. There’s no longer any difference in power for the DLL because of better DLL power management inside the DRAM device without any benefit for using slow exit. b. IDD6 is renamed IDD6N Self Refresh Current: Normal Temperature Range c. IDD6ET is renamed IDD6E Self-Refresh Current: Extended Temperature Range d. IDD6TC is renamed IDD6AAut0 Self-Refresh Current e. IDD8 is redefined from (optional) RESET Low Current to IDD8 Maximum Power Down Current, TBD 2) IDD values are an average (not peak) current drawn throughout the entire time that it takes to execute the set of conditions specified by JEDEC standards. 3) Consult with Viking for tools to help specify the Total Design Power (TDP) Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 22 of 42 vikingtechnology.com IDD6 Specification Symbol IDD6N IDD6E IDD6R IDD6A Temperature Range o 0 - 85 C o 0 - 95 C o 0 - 45 C o 0 C ~ Ta Tb ~ Ty Tz ~ TOPERmax Value 22 33 10 9 10 16 Unit mA mA mA mA mA mA Notes 3,4 4,5,6 4,6,9 4,6,7,8 4,6,7,8 4,6,7,8 Notes: 1. Some IDD currents are higher for x16 organization due to larger page-size architecture. 2. Max. values for IDD currents considering worst case conditions of process, temperature and voltage. 3. Applicable for MR2 settings A6=0 and A7=0. 4. Supplier data sheets include a max value for IDD6. 5. Applicable for MR2 settings A6=0 and A7=1. IDD6ET is only specified for devices which support the Extended Temperature Range feature. 6. Refer to the supplier data sheet for the value specification method (e.g. max, typical) for IDD6ET and IDD6TC 7. Applicable for MR2 settings A6=1 and A7=0. IDD6TC is only specified for devices which support the Auto Self Refresh feature. 8. The number of discrete temperature ranges supported and the associated Ta - Tz values are supplier/design specific. Temperature ranges are specified for all supported values of TOPER. Refer to supplier data sheet for more information. 9. Applicable for MR2 settings TBD. IDD6R is verified by design and characterization, and may not be subject to production test. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 23 of 42 vikingtechnology.com IDD CURRENTS, SINGLE RANK, 4Gbit Symbol DDR4-1866 DDR4-2133 DDR4-2400 Units IDD0 IPP0 IDD1 IDD2N IDD2NT IDD2P IDD2Q IDD3N IPP3N IDD3P IDD4R IDDQ4R IDD4W IDD5B IPP5B IDD6N IDD6E IDD6R IDD6A (25°C) IDD6A (45°C) IDD6A (75°C) IDD7 IPP7 IDD8 522 36 567 396 450 270 351 549 27 396 1260 288 1404 1710 198 180 243 90 81 90 144 1440 90 162 540 36 585 414 486 270 351 567 27 396 1350 324 1584 1710 198 180 243 90 81 90 144 1665 108 162 576 36 612 450 522 288 369 603 27 396 1440 360 1764 1728 198 180 243 90 81 90 144 1890 126 162 mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA Notes: 1. Users should refer to the DRAM supplier data sheet and/or the DIMM SPD to determine if DDR4 SDRAM devices support the following options or requirements referred to in this material. 2. Values as per Micron Datasheet Revision “A”. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 24 of 42 vikingtechnology.com IDD CURRENTS, 2 RANK, 4Gbit Symbol 1 IDD0 IPP01 IDD11 IDD2N2 IDD2NT1 IDD2P2 IDD2Q2 IDD3N2 IPP3N2 IDD3P2 IDD4R1 IDDQ4R1 IDD4W1 IDD5B1 IPP5B1 IDD6N2 IDD6E2 IDD6R2 IDD6A2 (25°C) IDD6A2 (45°C) IDD6A2 (75°C) IDD71 IPP71 IDD82 DDR4-1866 DDR4-2133 DDR4-2400 Units 792 306 837 792 720 540 702 1098 54 792 1530 558 1674 1980 468 360 486 180 162 180 288 1710 360 324 810 306 855 828 756 540 702 1134 54 792 1620 594 1854 1980 468 360 486 180 162 180 288 1935 378 324 864 324 900 900 810 576 738 1206 54 792 1728 648 2052 2016 468 360 486 180 162 180 288 2178 414 324 mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA Notes: 1. One module rank in the active IDD/PP, the other rank in IDD2P/PP3N. 2. All ranks in this IDD/PP condition. 3. Values as per Micron Datasheet Revision “A. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 25 of 42 vikingtechnology.com IDD CURRENTS, SINGLE RANK, 8Gbit DDR4-2133 15-15-15 1.2V DDR4-2400 17-17-17 1.2V IDD0 IDD0A IDD1 IDD1A IDD2N IDD2NA IDD2NT IDD2NL IDD2NG IDD2ND IDD2N_par IDD2P IDD2Q IDD3N IDD3NA IDD3P IDD4R IDD4RA IDD4RB IDD4W IDD4WA IDD4WB IDD4WC IDD4W_par IDD5B 315 333 450 468 198 225 225 135 198 180 207 144 180 324 342 189 927 963 945 756 792 846 666 828 1971 333 351 477 504 207 234 234 153 207 189 216 144 189 324 342 198 1017 1062 1044 810 855 810 720 891 1998 mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA IDD5F2 IDD5F4 1386 1152 207 306 1530 99 1395 1170 207 306 1557 99 mA mA Symbol IDD6N IDD6E IDD7 IDD8 Notes: 1. 2. Units mA mA mA mA Users should refer to the DRAM supplier data sheet and/or the DIMM SPD to determine if DDR4 SDRAM devices support the following options or requirements referred to in this material. Samsung D – Die referred for Idd values. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 26 of 42 vikingtechnology.com IDD CURRENTS, DUAL RANK, 8Gbit Symbol 1 IDD0 1 IDD0A 1 IDD1 1 IDD1A 2 IDD2N 1 IDD2NA 1 IDD2NT 1 IDD2NL 1 IDD2NG 1 IDD2ND 1 IDD2N_par 2 IDD2P 2 IDD2Q 2 IDD3N 2 IDD3NA 2 IDD3P 1 IDD4R 1 IDD4RA 1 IDD4RB 1 IDD4W 1 IDD4WA 1 IDD4WB 1 IDD4WC 1 IDD4W_par 1 IDD5B 1 IDD5F2 1 IDD5F4 2 IDD6N 2 IDD6E 1 IDD7 2 IDD8 DDR4-2133 15-15-15 1.2V DDR4-2400 17-17-17 1.2V 459 477 594 612 396 369 369 279 342 324 351 288 477 495 621 648 414 378 378 297 351 333 360 288 mA mA mA mA mA mA mA mA mA mA mA mA 360 648 684 378 1071 1107 1089 900 936 990 810 972 2115 1530 1296 414 612 1674 198 378 648 684 396 1161 1206 1188 954 999 954 864 1035 2142 1539 1314 414 612 1701 198 mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA mA Units Notes: 1. One module rank in the active IDD/PP, the other rank in IDD2P/PP3N. 2. All ranks in this IDD/PP condition. 3. Users should refer to the DRAM supplier data sheet and/or the DIMM SPD to determine if DDR4 SDRAM devices support the following options or requirements referred to in this material. 4. Samsung D – Die referred for Idd values. . Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 27 of 42 vikingtechnology.com Input/Output Capacitance Symbol Parameter DDR4-1600, 1867, 2133 DDR4-2400,2667 DDR4-3200 Min Max Min Max Min Max Units Note CIO Input/output capacitance 0.7 1.4 0.7 1.3 TBD TBD pF CDIO Input/output capacitance delta -0.1 0.1 -0.1 0.1 TBD TBD pF 1,2,3 1,2,3,1 1 CDDQS CCK Input/output capacitance delta DQS and DQS# Input capacitance, CK and CK# 0.2 0.05 0.8 0.2 0.05 0.8 TBD TBD TBD TBD pF pF 1,2,3,5 1,3 CDCK Input capacitance delta CK and CK# 0.05 TBD TBD pF 1,3,4 CI CDI_CTRL CDl_ADD_CMD CALERT CZQ Input capacitance(CTRL, ADD, CMD pins only) Input capacitance delta(All CTRL pins only) Input capacitance delta(All ADD/CMD pins only) lnput/output capacitance of ALERT Input/output capacitance of ZQ 0.05 0.2 0.8 0.2 0.7 TBD TBD pF 1,3,6 -0.1 0.1 -0.1 0.1 TBD TBD pF 1,3,7,8 -0.1 0.1 -0.1 0.1 TBD TBD pF 1,2,9, 10 0.5 0.5 1.5 1.5 0.5 0.5 1.5 1.5 TBD TBD TBD TBD pF pF 1,3 1,3,12 Notes: 1. This parameter is not subject to production test. It is verified by design and characterization. The silicon only capacitance is validated by de-embedding the package L & C parasitic. The capacitance is measured with VDD, VDDQ, VSS, VSSQ applied with all other signal pins floating. Measurement procedure tbd. 2. DQ, DM, DQS_T, DQS_C, TDQS_T, TDQS_C. Although the DM, TDQS_T and TDQS_C pins have different functions, the loading matches DQ and DQS 3. This parameter applies to monolithic devices only; stacked/dual-die devices are not covered here. 4. Absolute value CK_T-CK_C 5. Absolute value of CIO(DQS_T)-CIO(DQS_C) 6. CI applies to ODT, CS_n, CKE, A0-A17, BA0-BA1, BG0-BG1, RAS_n, CAS_n, WE_n. 7. CDI CTRL applies to ODT, CS_n and CKE 8. CDI_CTRL = CI(CTRL)-0.5*(CI(CLK_T)+CI(CLK_C)) 9. CDI_ADD_ CMD applies to, A0-A17, BA0-BA1, BG0-BG1, RAS_n, CAS_n, WE_n. 10. CDI_ADD_CMD = CI(ADD_CMD)-0.5*(CI(CLK_T)+CI(CLK_C)) 11. CDIO = CIO(DQ,DM)-0.5*(CIO(DQS_T)+CIO(DQS_C)) 12. Maximum external load capacitance on ZQ pin: tbd pF DC and AC Specifications for the SMBus Interface The specifications for the SMBus follow JEDEC standards. Datasheet PS9MUxx72x8xxx_VP Revision A 3/13/2017 Viking Technology Page 28 of 42 vikingtechnology.com Speed Bins by Speed Grade DDR4-1600 Speed Bins and Operating Conditions Speed Bin DDR4-1600 CL-nRCD-nRP 11-11-11 Parameter Symbol Min Unit NOTE Max 14 Internal read command to first data tAA 13.75 5,12 (13.50) 18 ns Internal read command to first data with read DBI enabled tAA_DBI tAA(min) + 2nCK tAA(max) +2nCK ns ACT to internal read or write delay time tRCD 13.75 5,12 (13.50) - ns PRE command period tRP 13.75 5,12 (13.50) - ns ACT to PRE command period tRAS 35 9 x tREFI ns ACT to ACT or REF command period tRC 48.75 5,12 (48.50) - ns Normal Read DBI CL = 9 CL = 11 5 (Optional) tCK(AVG) CL = 10 CL = 12 tCK(AVG) CL = 10 CL = 12 tCK(AVG) CL = 11 CL = 13 tCK(AVG) 1.25 CL = 12 CL = 14 tCK(AVG) 1.25 CWL = 9 CWL = 9,11 ns 1,2,3,4,11 ,14 ns 1,2,3,4,11 ns 1,2,3,4
VP9MU2G7228JBHSB 价格&库存

很抱歉,暂时无法提供与“VP9MU2G7228JBHSB”相匹配的价格&库存,您可以联系我们找货

免费人工找货