3M™ Ethylene Oxide Diffusion
Monitor 3550/3551
Overview/Benefits
• Simple and convenient.
• No batteries, hoses or
pumps to operate.
• Easy to use. Just clip the
monitor to shirt lapel, collar,
or pocket.
• Versatile. 3M monitors
can also be used for area
monitoring, if sufficient air
flow exists.
• Analysis options.
3M monitors can be
analyzed in the lab of
your choice or returned
to a 3M contracted lab
for analysis.
• Confidence. Our testing
facilities are accredited
by the American Industrial
Hygiene Association.
• Comfort. 3M monitors
are small and lightweight
and will not interfere with
employee activities.
The 3M™ Diffusion Monitor is a sampling device designed to
measure average concentrations of certain contaminants over
a measured time interval. It can be used for either personal
or area monitoring. As a personal monitor, it is worn near the
breathing zone of individuals exposed to potentially hazardous
environments. When used as an area monitor, hang it away
from walls, corners, table tops, or other regions where the air
movement in the room may be limited.
Product Information
3550 and 3551 ethylene oxide diffusion monitors contain a single treated charcoal
adsorbent pad. The 3550/3551 must be analyzed within 4 weeks after sampling. The
3550 includes a prepaid analysis (NOT sold in Canada). The 3551 monitor is designed to
be analyzed by the user or by an independent laboratory.
3M Monitor prepaid analysis services will be provided by an American Industrial
Hygiene Association (AIHA®) Accredited Laboratory. Confidentiality of customer
analysis results will be maintained. A written report will be quickly returned to
document the results of the analysis.
Meets current OSHA accuracy requirements for 8-hour sampling which are +/- 25%
at 1.0 ppm, +/- 35% at 0.5 ppm. Also meets accuracy requirements for short-term
exposure limit (STEL) sampling of +/- 35% at 5.0 ppm.
Store in an area free of organic vapors and/or ethylene oxide.
Shelf life is 18 months from date of manufacture. Expiration date is printed on packaging
in a MM_YY format.
Sampling times should be selected for comparison with appropriate exposure limits. For more
information regarding sampling times, contact PSD Technical Service at 1-800-243-4630.
For more information, please call 3M Technical Service at 1-800-243-4630 or see the
User Instructions.
Assembly Instructions
Remove the plastic lid from the can. Open can by grasping the ring tab and pulling up.
Examine the contents carefully to make sure all of the parts listed below are included.
1. Pour spout (short plastic straw).
2. Elution cap (clear plastic with plugs).
3. Monitor (maroon with metal clip).
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Sampling Instructions
1. Remove the diffusion monitor from the can.
2. Before monitoring, record the following information in your data log and on the enclosed form:
1) monitor serial number,
2) sampling date,
3) employee or area ID,
4) temperature and relative humidity,
5) compounds to be analyzed.
3. Record the date, employee or area ID and sampling start time on the monitor label (Fig. 1).
DO NOT REMOVE WHITE FILM AND PLASTIC RING.
4. Monitor can be used as an area or personal sampler. For personal sampler attach the monitor near employee breathing zone (Fig. 2). When
used as an area monitor, hang it away from walls, corners, table tops, or other regions where the air movement in the room may be limited.
5. After sampling period is ended, remove plastic ring and white film from the monitor (Fig. 3).
MOVE TO STEP 6 IMMEDIATELY.
6. Snap elution cap (with plugs) onto main monitor body (Fig. 4). Be sure the two port plugs are secured. Record final sampling time
on the back of monitor. Monitor is now ready for shipment.
7. Return monitor and short plastic straw to can and close with plastic lid provided.
8. 3551: Monitors do not include prepaid analysis; therefore, DO NOT RETURN TO 3M FOR ANALYSIS. Please see www.aiha.org for a
list of AIHA® accredited laboratories. A detailed analysis procedure is available from 3M.
3550: Send monitor plus completed analysis request form to:
EMSL Analytical, Inc.
3410 Winnetka Avenue North
Minneapolis, MN 55427
Good industrial hygiene practice indicates that a blank monitor be included with each set of samples to check for any contamination
of the samples. The blank is a monitor which has been handled in the same manner as the sample monitors, but has not been exposed
to the atmosphere in the area being monitored.
Reading the Report
The “Concentration” Column (circled)
is where you will find the average
concentration based upon the amount
found by the lab and the time that you
reported. This average may be converted
to an 8-hour time weighted average if
you wish to compare it against an
8-hour exposure limit.
Your returned Monitor Analysis Report will look like this:
Scenario 1:
Sample was for 6 hours and worker
was not exposed to contaminants for
the remaining 2 hours. The 8-hour TWA
may be determined using the following
equation:
(Report Concentration x 6 hours)
8 hours
Scenario 2:
Sample was for 6 hours, but worker has
the same exposure for the remaining
2 hours. Since the exposure in the
remaining 2 hours is the same, the report
concentration will be the same as the
8-hour TWA.
Please review the user instructions packaged with the product or contact 3M Technical
Service at 1-800-243-4630 if you have any questions or require additional information.
WARNING
Do Not Use For:
• Organic Vapors*, Ammonia, Carbon Monoxide; Formaldehyde#; Hydrogen Sulfide; Isocyantaes: Methane; Ethane; Propane;
Methyl Alcohol (Methanol); Methyl Chloride; Methyl, Dimethyl, Trimethyl Amines; Organic Solids; Sulfur Dioxide
• Reactive or polar compounds such as amines, phenols, aldehydes, and low molecular weight alcohols
• Extremely low concentrations within a sampling period of less than 8 hours
*Certain organic vapors can be monitored using 3M™ Organic Vapor Monitors 3500/3510/3520/3530.
#
Formaldehyde can be monitored using 3M™ Formaldehyde Monitor 3720/3721.
For product use instructions and limitations, see User Instructions Guide.
3
Personal Safety Division
3M Center, Building 0235-2W-70
St. Paul, MN 55144-1000
For more information:
In U.S.
Technical Assistance 1-800-243-4630
Customer Care Center 1-800-328-1667
3M.com/WorkerSafety
3M PSD products are occupational use only
In Canada
Technical Assistance 1-800-267-4414
Customer Care
1-800-364-3577
3M.ca/Safety
3M and all other trademarks used
herein are trademarks of 3M Company,
used under license in Canada.
© 3M 2019. All rights reserved.
很抱歉,暂时无法提供与“3550”相匹配的价格&库存,您可以联系我们找货
免费人工找货