0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MAX1202ACPP+

MAX1202ACPP+

  • 厂商:

    AD(亚德诺)

  • 封装:

    DIP

  • 描述:

    位模数转换器 输入

  • 数据手册
  • 价格&库存
MAX1202ACPP+ 数据手册
EVALUATION KIT AVAILABLE MAX1202/MAX1203 General Description The MAX1202/MAX1203 are 12-bit data-acquisition systems specifically designed for use in applications with mixed +5V (analog) and +3V (digital) supply voltages. They operate with a single +5V analog supply or dual ±5V analog supplies, and combine an 8-channel multiplexer, high-bandwidth track/hold, and serial interface with high conversion speed and low power consumption. A 4-wire serial interface connects directly to SPI/ MICROWIRE® devices without external logic, and a serial strobe output allows direct connection to TMS320-family digital signal processors. The MAX1202/MAX1203 use either the internal clock or an external serial-interface clock to perform successive approximation analog-to-digital conversions. The serial interface operates at up to 2MHz. The MAX1202 features an internal 4.096V reference, while the MAX1203 requires an external reference. Both parts have a reference-buffer amplifier that simplifies gain trim. They also have a VL pin that is the power supply for the digital outputs. Output logic levels (3V, 3.3V, or 5V) are determined by the value of the voltage applied to this pin. These devices provide a hard-wired SHDN pin and two software-selectable power-down modes. Accessing the serial interface automatically powers up the devices. A quick turn-on time enables the MAX1202/MAX1203 to be shut down between conversions, allowing the user to optimize supply currents. By customizing power-down between conversions, supply current can drop below 10μA at reduced sampling rates. The MAX1202/MAX1203 are available in 20-pin SSOP and PDIP packages, and are specified for the commercial and extended temperature ranges. Applications ●● ●● ●● ●● ●● 5V/3V Mixed-Supply Systems Data Acquisition High-Accuracy Process Control Battery-Powered Instruments Medical Instruments Typical Operating Circuit appears at end of data sheet. MICROWIRE is a registered trademark of National Semiconductor Corp. 19-1173; Rev 3; 3/12 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Features ●● 8-Channel Single-Ended or 4-Channel Differential Inputs ●● Operates from Single +5V or Dual ±5V Supplies ●● User-Adjustable Output Logic Levels (2.7V to 5.25V) ●● Low Power: 1.5mA (Operating Mode) 2μA (Power-Down Mode) ●● Internal Track/Hold, 133kHz Sampling Rate ●● Internal 4.096V Reference (MAX1202) ●● SPI/MICROWIRE/TMS320-Compatible 4-Wire Serial Interface ●● Software-Configurable Unipolar/Bipolar Inputs ●● 20-Pin PDIP/SSOP Ordering Information PART TEMP RANGE MAX1202ACPP+ 0ºC to +70ºC PINPACKAGE 20 PDIP MAX1202BCPP+ 0ºC to +70ºC 20 PDIP ±1 MAX1202ACAP+ 0ºC to +70ºC 20 SSOP ±1/2 MAX1202BCAP+ 0ºC to +70ºC 20 SSOP ±1 Ordering Information continued at end of data sheet. +Denotes a lead(Pb)-free/RoHS-compliant package. Pin Configuration TOP VIEW + 20 VDD CH0 1 CH1 2 CH2 3 CH3 4 CH4 5 CH5 6 15 DOUT CH6 7 14 VL CH7 8 13 GND VSS 9 12 REFADJ 19 SCLK MAX1202 MAX1203 18 CS 17 DIN 16 SSTRB 11 REF SHDN 10 PDIP/SSOP INL (LSB) ±1/2 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Absolute Maximum Ratings VDD to GND.............................................................-0.3V to +6V VL.............................................................. -0.3V to (VDD + 0.3V) VSS to GND..............................................................+0.3V to -6V VDD to VSS.............................................................-0.3V to +12V CH0–CH7 to GND.......................... (VSS - 0.3V) to (VDD + 0.3V) CH0–CH7 Total Input Current...........................................±20mA REF to GND.............................................. -0.3V to (VDD + 0.3V) REFADJ to GND........................................ -0.3V to (VDD + 0.3V) Digital Inputs to GND................................ -0.3V to (VDD + 0.3V) Digital Outputs to GND................................. -0.3V to (VL + 0.3V) Digital Output Sink Current.................................................25mA Continuous Power Dissipation (TA = +70°C) PDIP (derate 11.11mW/°C above +70°C).....................889mW SSOP (derate 8.00mW/°C above +70°C).....................640mW Operating Temperature Ranges MAX1202_C_P/MAX1203_C_P...........................0°C to +70°C MAX1202_E_P/MAX1203_E_P....................... -40°C to +85°C Storage Temperature Range............................. -60°C to +150°C Lead Temperature (soldering, 10s).................................. +300°C Soldering Temperature (reflow)........................................+260°C Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Electrical Characteristics (VDD = +5V ±5%, VL = 2.7V to 3.6V; VSS = 0V or -5V ±5%; fSCLK = 2.0MHz, external clock (50% duty cycle); 15 clocks/conversion cycle (133ksps); MAX1202—4.7μF capacitor at REF pin; MAX1203—external reference, VREF = 4.096V applied to REF pin; TA = TMIN to TMAX, unless otherwise noted.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS DC ACCURACY (Note 1) Resolution RES Relative Accuracy (Note 2) INL Differential Nonlinearity DNL 12 Bits MAX1202A/MAX1203A ±0.5 MAX1202B/MAX1203B ±1.0 no missing codes over temperature ±1.0 LSB ±3.0 LSB Offset Error MAX1202 (all grades) Gain Error (Note 3) External reference, 4.096V Gain Temperature Coefficient LSB ±3 MAX1203A ±1.5 MAX1203B ±3 External reference, 4.096V Channel-to-Channel Offset Matching LSB ±0.8 ppm/°C ±0.1 LSB DYNAMIC SPECIFICATIONS (10kHz sine-wave input, 4.096VP-P, 133ksps, 2.0MHz external clock, bipolar-input mode) Signal-to-Noise Plus Distortion Ratio SINAD Total Harmonic Distortion (up to the 5th Harmonic) THD Spurious-Free Dynamic Range 70 dB -80 SFDR 80 dB dB Channel-to-Channel Crosstalk VIN = 4.096VP-P, 65kHz (Note 4) -85 dB Small-Signal Bandwidth -3dB rolloff 4.5 MHz 800 kHz Full-Power Bandwidth www.maximintegrated.com Maxim Integrated │  2 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Electrical Characteristics (continued) (VDD = +5V ±5%, VL = 2.7V to 3.6V; VSS = 0V or -5V ±5%; fSCLK = 2.0MHz, external clock (50% duty cycle); 15 clocks/conversion cycle (133ksps); MAX1202—4.7μF capacitor at REF pin; MAX1203—external reference, VREF = 4.096V applied to REF pin; TA = TMIN to TMAX, unless otherwise noted.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS CONVERSION RATE Conversion Time (Note 5) Track/Hold Acquisition Time tCONV Internal clock External clock, 2MHz, 12 clocks/conversion tACQ 5.5 10 6 1.5 µs µs Aperture Delay 10 ns Aperture Jitter < 50 ps Internal Clock Frequency External Clock Frequency Range 1.7 MHz External compensation mode, 4.7µF 0.1 2.0 Internal compensation mode (Note 6) 0.1 0.4 0 2.0 Used for data transfer only MHz ANALOG INPUT Input Voltage Range, Single-Ended and Differential (Note 7) Unipolar, VSS = 0V VREF Bipolar, VSS = -5V ±VREF/2 Multiplexer Leakage Current On/off-leakage current, VCH_ = ±5V ±0.01 Input Capacitance (Note 6) 16 ±1 V µA pF INTERNAL REFERENCE (MAX1202 only, reference-buffer enabled) REF Output Voltage TA = +25°C 4.076 4.096 4.116 V 30 mA MAX1202AC ±30 ±50 MAX1202AE ±30 ±60 MAX1202B ±30 0 to 0.5mA output load 2.5 REF Short-Circuit Current VREF Temperature Coefficien Load Regulation (Note 8) Capacitive Bypass at REF Internal compensation mode 0 External compensation mode 4.7 Capacitive Bypass at REFADJ mV µF 0.01 REFADJ Adjustment Range ppm/°C µF % ±1.5 EXTERNAL REFERENCE AT REF (Reference buffer disabled, VREF = 4.096V) Input Voltage Range 2.50 Input Current 200 Input Resistance REF Input Current in Shutdown REFADJ Buffer Disable Threshold www.maximintegrated.com 12 VSHDN = 0V V 350 µA 20 1.5 VDD 50mV VDD + 50mV kΩ 10 µA V Maxim Integrated │  3 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Electrical Characteristics (continued) (VDD = +5V ±5%, VL = 2.7V to 3.6V; VSS = 0V or -5V ±5%; fSCLK = 2.0MHz, external clock (50% duty cycle); 15 clocks/conversion cycle (133ksps); MAX1202—4.7μF capacitor at REF pin; MAX1203—external reference, VREF = 4.096V applied to REF pin; TA = TMIN to TMAX, unless otherwise noted.) PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS EXTERNAL REFERENCE AT REFADJ Capacitive Bypass at REF Reference-Buffer Gain REFADJ Input Current Internal compensation mode 0 External compensation mode 4.7 µF MAX1202 1.68 MAX1203 1.64 V/V MAX1202 ±50 MAX1203 ±5 µA POWER REQUIREMENTS Positive Supply Voltage VDD 5 ±5% V Negative Supply Voltage VSS 0 or 5 ±5% V Positive Supply Current IDD Operating mode 1.5 2.5 Fast power-down (Note 9) 30 70 Full power-down (Note 9) 2 10 Operating mode and fast power-down 50 Full power-down 10 Negative Supply Current ISS Logic Supply Voltage VL Logic Supply Current (Notes 6, 10) IL Positive Supply Rejection (Note 11) PSR VDD = 5V ±5%; external reference, 4.096V; full-scale input Negative Supply Rejection (Note 11) PSR Logic Supply Rejection (Note 12) PSR www.maximintegrated.com 2.70 mA µA µA 5.25 V 10 µA ±0.06 ±0.5 mV VSS = -5V ±5%; external reference, 4.096V; full-scale input ±0.01 ±0.5 mV External reference, 4.096V; full-scale input ±0.06 ±0.5 mV VL = VDD = 5V Maxim Integrated │  4 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Electrical Characteristics (continued) (VDD = +5V ±5%, VL = 2.7V to 3.6V; VSS = 0V or -5V ±5%; fSCLK = 2.0MHz, external clock (50% duty cycle); 15 clocks/conversion cycle (133ksps); MAX1202—4.7μF capacitor at REF pin; MAX1203—external reference, VREF = 4.096V applied to REF pin; TA = TMIN to TMAX, unless otherwise noted.) PARAMETER SYMBOL CONDITIONS DIGITAL INPUTS—DIN, SCLK, CS, SHDN DIN, SCLK, CS Input High Voltage DIN, SCLK, CS Input Low Voltage DIN, SCLK, CS Input Hysteresis DIN, SCLK, CS Input Leakage VIH MIN TYP 2.0 0.8 0.15 IIN VIN = 0V or VDD DIN, SCLK, CS Input Capacitance CIN (Note 6) SHDN Input High Voltage VSH VSM SHDN Voltage, Unconnected VFLT 1.5 SHDN Input Low Voltage VSL SHDN Input Current, High ISH SHDN = VDD SHDN Input Current, Low ISL VSHDN = 0V -4.0 SHDN = open -100 SHDN = open V V ±1 µA 15 pF VDD - 0.5 SHDN Input Mid Voltage UNITS V VIL VHYST SHDN Maximum Allowed Leakage, Mid-Input MAX V VDD - 1.5 2.75 V V 0.5 V 4.0 µA µA +100 nA DIGITAL OUTPUTS—DOUT, SSTR (VL = 2.7V to 3.6V) ISINK = 3mA 0.4 Output Voltage Low VOL Output Voltage High VOH ISOURCE = 1mA Three-State Leakage Current ILEAK CS = VL ±10 µA Three-State Output Capacitance COUT CS = VL (Note 6) 15 pF ISINK = 6mA 0.3 VL - 0.5 V V DIGITAL OUTPUTS—DOUT, SSTR (VL = 4.75V to 5.25V) Output Voltage Low VOL ISINK = 5mA 0.4 ISINK = 8mA 0.3 Output Voltage High VOH ISOURCE = 1mA Three-State Leakage Current ILEAK VCS = 5V ±10 µA Three-State Output Capacitance COUT VCS = 5V (Note 6) 15 pF www.maximintegrated.com 4 V V Maxim Integrated │  5 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface TIMING CHARACTERISTICS (VDD = +5V ±5%, VL = 2.7V to 3.6V, VSS = 0V or -5V ±5%, TA = TMIN to TMAX, unless otherwise noted.) PARAMETER Acquisition Time SYMBOL CONDITIONS MIN TYP MAX UNITS tACQ 1.5 µs DIN to SCLK Setup tDS 100 ns DIN to SCLK Hold tDH SCLK Fall to Output Data Valid tDO CLOAD = 100pF CS Fall to Output Enable tDV CLOAD = 100pF tTR CLOAD = 100pF CS Rise to Output Disable 20 0 ns 240 ns 240 ns 240 ns CS to SCLK Rise Setup tCSS 100 ns CS to SCLK Rise Hold tCSH 0 ns SCLK Pulse Width High tCH 200 ns SCLK Pulse Width Low tCL 200 ns SCLK Fall to SSTRB CLOAD = 100pF tSSTRB CS Fall to SSTRB Output Enable (Note 6) tSDV CS Rise to SSTRB Output Disable (Note 6) tSTR SSTRB Rise to SCLK Rise (Note 6) tSCK External-clock mode only, CLOAD = 100pF 0 240 ns 240 ns 240 ns ns Note 1: Tested at VDD = 5.0V; VSS = 0V; unipolar-input mode. Note 2: Relative accuracy is the analog value’s deviation (at any code) from its theoretical value after the full-scale range is calibrated. Note 3: MAX1202—internal reference, offset nulled; MAX1203—external reference (VREF = 4.096V), offset nulled. Note 4: On-channel grounded; sine wave applied to all off-channels. Note 5: Conversion time is defined as the number of clock cycles multiplied by the clock period; clock has 50% duty cycle. Note 6: Guaranteed by design. Not production tested. Note 7: Common-mode range for analog inputs is from VSS to VDD. Note 8: External load should not change during the conversion for specified accuracy. Note 9: Shutdown supply current is measured with VL at 3.3V, and with all digital inputs tied to either VL or GND; REFADJ = GND. Shutdown supply current is also dependent on VIH (Figure 12c). Note 10: Logic supply current is measured with the digital outputs (DOUT and SSTRB) disabled (CS high). When the outputs are active (CS low), the logic supply current depends on fSCLK, and on the static and capacitive load at DOUT and SSTRB. Note 11: Measured at VSUPPLY + 5% and VSUPPLY - 5% only. Note 12: Measured at VL = 2.7V and VL = 3.6V. www.maximintegrated.com Maxim Integrated │  6 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Typical Operating Characteristics (VDD = 5V ±5%; VL = 2.7V to 3.6V; VSS = 0V; fSCLK = 2.0MHz, external clock (50% duty cycle); 15 clocks/conversion cycle (133ksps); MAX1202—4.7μF capacitor at REF pin; MAX1203—external reference, VREF = 4.096V applied to REF pin; TA = +25°C, unless otherwise noted.) 1.6 MAX1202 1.4 1.2 4.7 4.9 5.1 2.0 MAX1202 1.5 MAX1203 1.0 0.5 5.3 0 5.5 -60 -20 20 60 100 5 3 2 1 -60 -20 60 20 TEMPERATURE (°C) TEMPERATURE (ºC) INTEGRAL NONLINEARITY vs. TEMPERATURE OFFSET ERROR vs. TEMPERATURE GAIN ERROR vs. TEMPERATURE 1.5 0.5 0.4 0.3 0.2 1.0 0.5 0 -0.5 -1.0 2 0 -1 -4 -5 140 -60 -20 20 60 2 1 0 -1 -2 5 -20 60 20 CHANNEL-TO-CHANNEL GAIN-ERROR MATCHING vs. TEMPERATURE 4 GAIN-ERROR MATCHING (LSB) MAX1202 TOC07 OFFSET-ERROR MATCHING (LSB) -60 TEMPERATURE (ºC) CHANNEL-TO-CHANNEL OFFSET-ERROR MATCHING vs. TEMPERATURE -3 140 100 TEMPERATURE (ºC) MAX1202 toc08 TEMPERATURE (ºC) 3 140 -3 -2.0 100 SINGLE-ENDED -2 0 60 DIFFERENTIAL 1 -1.5 20 100 3 0.1 -20 140 4 GAIN ERROR (LSB) OFFSET ERROR (LSB) 0.6 5 100 MAX1202 toc06 2.0 MAX1202 toc05 0.7 -60 REFADJ = GND FULL POWER-DOWN 4 0 140 MAX1202 toc03 6 SHUTDOWN SUPPLY CURRENT vs. TEMPERATURE SUPPLY VOLTAGE (V) MAX1202 toc04 0.8 INL (LSB) 2.5 MAX1203 4.5 MAX1202 toc02 MAX1202 toc01 1.8 1.0 3.0 SUPPLY CURRENT (mA) SUPPLY CURRENT (mA) 2.0 SUPPLY CURRENT vs. TEMPERATURE SHUTDOWN SUPPLY CURRENT (mA) SUPPLY CURRENT vs. SUPPLY VOLTAGE 3 2 1 0 -1 -2 -3 -4 -60 -20 20 60 TEMPERATURE (ºC) www.maximintegrated.com 100 140 -5 -60 -20 20 60 100 140 TEMPERATURE (ºC) Maxim Integrated │  7 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Typical Operating Characteristics (continued) (VDD = 5V ±5%; VL = 2.7V to 3.6V; VSS = 0V; fSCLK = 2.0MHz, external clock (50% duty cycle); 15 clocks/conversion cycle (133ksps); MAX1202—4.7μF capacitor at REF pin; MAX1203—external reference, VREF = 4.096V applied to REF pin; TA = +25°C, unless otherwise noted.) INTEGRAL NONLINEARITY vs. DIGITAL 0.8 0.6 AMPLITUDE (dB) INL (LSB) 0.4 0.2 0 -0.2 -0.4 -20 -40 -60 -80 -0.6 -100 -0.8 -1.0 VSS = -5V 0 MAX1202 toc10 FFT PLOT 20 MAX1202 toc09 1.0 0 750 1500 2250 3000 3750 -120 4500 0 DIGITAL CODE 33.25 66.50 FREQUENCY (kHz) Pin Description PIN NAME 1–8 CH0–CH7 9 VSS FUNCTION Sampling Analog Inputs Negative Supply Voltage. Tie VSS to -5V ±5% or to GND. Three-Level Shutdown Input. Pulling SHDN low shuts the MAX1202/MAX1203 down to 10µA (max) supply current; otherwise, the MAX1202/MAX1203 are fully operational. Pulling SHDN to VDD puts the reference-buffer amplifier in internal compensation mode. Leaving SHDN unconnected puts the reference-buffer amplifier in external compensation mode. 10 SHDN 11 REF 12 REFADJ 13 GND 14 VL 15 DOUT Serial-Data Output. Data is clocked out at SCLK’s falling edge. High impedance when CS is high. 16 SSTRB Serial-Strobe Output. In internal clock mode, SSTRB goes low when the MAX1202/MAX1203 begin the analog-to-digital conversion, and goes high when the conversion is finished. In external clock mode, SSTRB pulses high for one clock period before the MSB decision. High impedance when CS is high (external clock mode). 17 DIN Serial-Data Input. Data is clocked in at SCLK’s rising edge. 18 CS Active-Low Chip Select. Data is not clocked into DIN unless CS is low. When CS is high, DOUT is high impedance. 19 SCLK 20 VDD www.maximintegrated.com Reference-Buffer Output/ADC Reference Input. In internal reference mode (MAX1202 only), the reference buffer provides a 4.096V nominal output, externally adjustable at REFADJ. In external reference mode, disable the internal buffer by pulling REFADJ to VDD. Input to the Reference-Buffer Amplifier. Tie REFADJ to VDD to disable the reference-buffer amplifier. Ground; IN- Input for Single-Ended Conversions Supply Voltage for Digital Output Pins. Voltage applied to VL determines the positive output swing of the Digital Outputs (DOUT, SSTRB). 2.7V ≤ VL ≤ 5.25V. Serial-Clock Input. SCLK clocks data in and out of the serial interface. In external clock mode, SCLK also sets the conversion speed (Duty cycle must be 40% to 60% in external clock mode). Positive Supply Voltage, +5V ±5% Maxim Integrated │  8 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface +3.3V 3kΩ DOUT DOUT 3kΩ CLOAD CLOAD GND GND a. High-Z to VOH and VOL to VOH b. High-Z to VOL and VOH to VOL Figure 1. Load Circuits for Enable Time +3.3V DOUT DOUT 3kΩ CLOAD GND a. VOH to High-Z 3kΩ CLOAD CS SCLK 18 19 DIN 17 SHDN 10 CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 1 2 3 4 5 6 7 8 GND 13 REFADJ 12 REF 11 INPUT SHIFT REGISTER ANALOG INPUT MUX CONTROL LOGIC INT CLOCK OUTPUT SHIFT REGISTER 15 16 DOUT SSTRB T/H CLOCK IN 12-BIT SAR ADC OUT MAX1202 MAX1203 REF +2.44V REFERENCE 20kΩ (MAX1202) A ª 1.68 20 14 9 VDD VL VSS +4.096V GND b. VOL to High-Z Figure 2. Load Circuits for Disable Time Figure 3. Block Diagram Detailed Description to GND during a conversion. To do this, connect a 0.1μF capacitor from IN- (of the selected analog input) to GND. The MAX1202/MAX1203 analog-to-digital converters (ADCs) use a successive-approximation conversion technique and input track/hold (T/H) circuitry to convert an analog signal to a 12-bit digital output. A flexible serial interface provides easy interface to 3V microprocessors (μPs). Figure 3 is the MAX1202/MAX1203 block diagram. Pseudo-Differential Input Figure 4 shows the ADC’s analog comparator’s sampling architecture. In single-ended mode, IN+ is internally switched to CH0–CH7 and IN- is switched to GND. In differential mode, IN+ and IN- are selected from pairs of CH0/CH1, CH2/CH3, CH4/CH5, and CH6/CH7. Configure the channels using Tables 3 and 4. In differential mode, IN- and IN+ are internally switched to either of the analog inputs. This configuration is pseudodifferential such that only the signal at IN+ is sampled. The return side (IN-) must remain stable (typically within ±0.5 LSB, within ±0.1 LSB for best results) with respect www.maximintegrated.com During the acquisition interval, the channel selected as the positive input (IN+) charges capacitor CHOLD. The acquisition interval spans three SCLK cycles and ends on the falling SCLK edge after the input control word’s last bit is entered. The T/H switch opens at the end of the acquisition interval, retaining charge on CHOLD as a sample of the signal at IN+. The conversion interval begins with the input multiplexer switching CHOLD from the positive input (IN+) to the negative input (IN-). In single-ended mode, IN- is simply GND. This unbalances node ZERO at the comparator’s input. The capacitive DAC adjusts during the remainder of the conversion cycle to restore node ZERO to 0V within the limits of 12-bit resolution. This action is equivalent to transferring a charge of 16pF x [(VIN+) - (VIN-)] from CHOLD to the binary-weighted capacitive DAC, which in turn forms a digital representation of the analog input signal. Maxim Integrated │  9 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Track/Hold The T/H enters tracking mode on the falling clock edge after the fifth bit of the 8-bit control word is shifted in. The T/H enters hold mode on the falling clock edge after the eighth bit of the control word is shifted in. IN- is connected to GND if the converter is set up for single-ended inputs, and the converter samples the “+” input. IN- connects to the “-” input if the converter is set up for differential inputs, and the difference of |N+ - IN-| is sampled. The positive input connects back to IN+, at the end of the conversion, and CHOLD charges to the input signal. The time required for the T/H to acquire an input signal is a function of how quickly its input capacitance is charged. If the input signal’s source impedance is high, acquisition time increases and more time must be allowed between conversions. The acquisition time, tACQ, is the maximum time the device takes to acquire the signal, and is also the minimum time needed for the signal to be acquired. It is calculated by the following: tACQ = 9 x (RS + RIN) x 16pF where RIN = 9kΩ, RS = the source impedance of the input signal, and tACQ is never less than 1.5μs. Source impedances below 1kΩ do not significantly affect the ADC’s AC +3V 0.1µF VL performance. Higher source impedances can be used if an input capacitor is connected to the analog inputs, as shown in Figure 5. Note that the input capacitor forms an RC filter with the input source impedance, limiting the ADC’s signal bandwidth. 12-BIT CAPACITIVE DAC REF CH0 CH1 INPUT MUX – CH4 CH5 CH6 CH7 CSWITCH 9kΩ RIN HOLD TRACK T/H SWITCH GND AT THE SAMPLING INSTANT, THE MUX INPUT SWITCHES FROM THE SELECTED IN+ CHANNEL TO THE SELECTED IN- CHANNEL. SINGLE-ENDED MODE: IN+ = CHO–CH7, IN- = GND. DIFFERENTIAL MODE: IN+ AND IN- SELECTED FROM PAIRS OF CH0/CH1, CH2/CH3, CH4/CH5, CH6/CH7. Figure 4. Equivalent Input Circuit VDD OSCILLOSCOPE +5V 0.1µF ZERO 16pF CH2 CH3 COMPARATOR CHOLD + 4.7µF GND 0 TO 4.096V ANALOG 0.01µF INPUT CH7 SCLK VSS MAX1202 MAX1203 SSTRB CS DOUT* SCLK +3V DIN 2MHz OSCILLATOR CH1 CH2 CH3 CH4 SSTRB C2 0.01µF C1 4.7µF REFADJ DOUT REF SHDN +2.5V N.C.*** ** +2.5V REFERENCE *FULL-SCALE ANALOG INPUT, CONVERSION RESULT = $FFF (HEX). **REQUIRED FOR MAX1203 ONLY. ***NO CONNECTION Figure 5. Quick-Look Circuit www.maximintegrated.com Maxim Integrated │  10 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Table 1a. Unipolar Full Scale and Zero Scale ZERO SCALE FULL SCALE 0V +4.096V at REFADJ 0V at REF 0V VREFADJ x A* REFERENCE Internal External VREF *A = 1.68 for the MAX1202, 1.64 for the MAX1203. Table 1b. Bipolar Full Scale, Zero Scale, and Negative Full Scale REFERENCE Internal at External REFADJ at REF NEGATIVE FULL SCALE ZERO SCALE FULL SCALE +4.096V/2 0V +4.096V/2 -1/2 VREFADJ x A* 0V +1/2 VREFADJ x A* +1/2 VREF 0V +1/2 VREF *A = 1.68 for the MAX1202, 1.64 for the MAX1203. Input Bandwidth The ADC’s input tracking circuitry has a 4.5MHz smallsignal bandwidth. Therefore it is possible to digitize highspeed transient events and measure periodic signals with bandwidths exceeding the ADC’s sampling rate by using undersampling techniques. To avoid high-frequency signals being aliased into the frequency band of interest, anti-alias filtering is recommended. Analog Input Range and Input Protection Internal protection diodes, which clamp the analog inputs to VDD and VSS, allow the analog input pins to swing from (VSS - 0.3V) to (VDD + 0.3V) without damage. However, for accurate conversions near full scale, the inputs must not exceed VDD by more than 50mV, or be lower than VSS by 50mV. If the analog input exceeds 50mV beyond the supplies, do not forward bias the protection diodes of off-channels more than 2mA. The full-scale input voltage depends on the voltage at REF (Tables 1a and 1b). Quick Look Use the circuit of Figure 5 to quickly evaluate the MAX1202/ MAX1203’s analog performance. The MAX1202/MAX1203 require a control byte to be written to DIN before each conversion. Tying DIN to +3V feeds in control byte $FF hex, www.maximintegrated.com which triggers single-ended unipolar conversions on CH7 in external clock mode without powering down between conversions. In external clock mode, the SSTRB output pulses high for one clock period before the most significant bit of the 12-bit conversion result shifts out of DOUT. Varying the analog input to CH7 alters the sequence of bits from DOUT. A total of 15 clock cycles per conversion is required. All SSTRB and DOUT output transitions occur on SCLK’s falling edge. How to Start a Conversion Clocking a control byte into DIN starts conversion on the MAX1202/MAX1203. With CS low, each rising edge on SCLK clocks a bit from DIN into the MAX1202/MAX1203’s internal shift register. After CS falls, the first logic “1” bit defines the control byte’s MSB. Until this first “start” bit arrives, any number of logic “0” bits can be clocked into DIN with no effect. Table 2 shows the control-byte format. The MAX1202/MAX1203 are fully compatible with SPI/ MICROWIRE devices. For SPI, select the correct clock polarity and sampling edge in the SPI control registers: set CPOL = 0 and CPHA = 0. MICROWIRE and SPI both transmit and receive a byte at the same time. Using the Typical Operating Circuit, the simplest software interface requires only three 8-bit transfers to perform a conversion (one 8-bit transfer to configure the ADC, and two more 8-bit transfers to clock out the 12-bit conversion result). Maxim Integrated │  11 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Table 2. Control-Byte Format BIT 7 (MSB) BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT1 BIT 0 (LSB) START SEL 2 SEL 1 SEL 0 UNI/BIP SGL/DIF PD1 PD0 BIT NAME 7 (MSB) START The first logic 1 bit after CS goes low defines the beginning of the control byte. 6 5 4 SEL2 SEL1 SEL0 These three bits select which of the eight channels is used for the conversion (Tables 3 and 4). 3 UNI/BIP 1 = unipolar, 0 = bipolar. Selects unipolar or bipolar conversion mode. In unipolar mode, an analog input signal from 0 to VREF can be converted; in bipolar mode, the signal can range from -VREF/2 to +VREF/2. 2 SGL/DIF 1 = single ended, 0 = differential. Selects single-ended or differential conversions. In single-ended mode, input signal voltages are referred to GND. In differential mode, the voltage difference between two channels is measured. (Tables 3 and 4). 1 0 (LSB) DESCRIPTION Selects clock and power-down modes. PD1 PD0 Mode 0 0 Full power-down (IDD = 2µA, internal reference) 0 1 Fast power-down (IDD = 30µA, internal reference) 1 0 Internal clock mode 1 1 External clock mode PD1 PD0 Table 3. Channel Selection in Single-Ended Mode (SGL/DIF = 1) SEL2 SEL1 SEL0 CH0 0 0 0 + 1 0 0 0 0 1 1 0 1 0 1 0 1 1 0 0 1 1 1 1 1 CH1 CH2 CH3 CH4 CH5 CH6 CH7 GND - + + + + + + + - Table 4. Channel Selection in Differential Mode (SGL/DIF = 0) SEL2 SEL1 SEL0 CH0 CH1 0 0 0 + - 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 www.maximintegrated.com - CH2 CH3 + - CH4 CH5 + - CH6 CH7 + - - + + - + - + Maxim Integrated │  12 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Simple Software Interface Digital Output Make sure the CPU’s serial interface runs in master mode so the CPU generates the serial clock. Choose a clock frequency from 100kHz to 2MHz. In unipolar-input mode, the output is straight binary (Figure 15); for bipolar inputs, the output is two’s complement (Figure 16). Data is clocked out at SCLK’s falling edge in MSB-first format. The digital output logic level is adjusted with the VL pin. This allows DOUT and SSTRB to interface with 3V logic without the risk of overdrive. The MAX1202/MAX1203’s digital inputs are designed to be compatible with 5V CMOS logic as well as 3V logic. 1) Set up the control byte for external clock mode and call it TB1. TB1’s format should be: 1XXXXX11 binary, where the Xs denote the particular channel and conversion mode selected. 2) Use a general-purpose I/O line on the CPU to pull CS on the MAX1202/MAX1203 low. Internal and External Clock Modes The MAX1202/MAX1203 can use either an external serial clock or the internal clock to perform the successiveapproximation conversion. In both clock modes, the external clock shifts data in and out of the MAX1202/ MAX1203. The T/H acquires the input signal as the last three bits of the control byte are clocked into DIN. Bits PD1 and PD0 of the control byte program the clock mode. Figures 7–10 show the timing characteristics common to both modes. 3) Transmit TB1 and simultaneously receive a byte and call it RB1. Ignore RB1. 4) Transmit a byte of all zeros ($00 hex) and simultaneously receive byte RB2. 5) Transmit a byte of all zeros ($00 hex) and simultaneously receive byte RB3. 6) Pull CS on the MAX1202/MAX1203 high. Figure 6 shows the timing for this sequence. Bytes RB2 and RB3 contain the result of the conversion padded with one leading zero and three trailing zeros. The total conversion time is a function of the serial-clock frequency and the amount of idle time between 8-bit transfers. To avoid excessive T/H droop, make sure that the total conversion time does not exceed 120μs. External Clock In external clock mode, the external clock not only shifts data in and out, but it also drives the A/D conversion steps. SSTRB pulses high for one clock period after the last bit of the control byte. Successive-approximation bit decisions are made and appear at DOUT on each of the next 12 SCLK falling edges (Figure 6). SSTRB and DOUT go into a high-impedance state when CS goes high; after CS tACQ SCLK 1 DIN SSTRB 4 SEL2 SEL1 SEL0 8 UNI/ SGL/ BIP DIF PD1 16 20 24 PD0 START RB1 B11 MSB DOUT ADC STATE 12 IDLE ACQUISITION 1.5µs (SCLK = 2MHz) RB3 RB2 B10 B9 B8 B7 B6 B5 B4 CONVERSION B3 B2 B1 B0 LSB FILLED WITH ZEROS IDLE Figure 6. 24-Bit External Clock Mode Conversion Timing (MICROWIRE and SPI Compatible) www.maximintegrated.com Maxim Integrated │  13 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface ••• CS tCSH tCSS tCL tCH SCLK tCSH ••• tDS tDH DIN ••• tDV tDO DOUT tTR ••• Figure 7. Detailed Serial-Interface Timing CS ••• ••• tSTR tSDV SSTRB ••• ••• tSSTRB SCLK ••• tSSTRB ••• PD0 CLOCKED IN Figure 8. External Clock Mode SSTRB Detailed Timing the next CS falling edge, SSTRB outputs a logic low. Figure 8 shows SSTRB timing in external clock mode. The conversion must complete in some minimum time or droop on the sample-and-hold capacitors might degrade conversion results. Use internal clock mode if the clock period exceeds 10μs or if serial-clock interruptions could cause the conversion interval to exceed 120μs. Internal Clock In internal clock mode, the MAX1202/MAX1203 generate their own conversion clock. This frees the μP from run- www.maximintegrated.com ning the SAR conversion clock, and allows the conversion results to be read back at the processor’s convenience, at any clock rate from zero to 2MHz. SSTRB goes low at the start of the conversion, then goes high when the conversion is complete. SSTRB is low for a maximum of 10μs, during which time SCLK should remain low for best noise performance. An internal register stores data while the conversion is in progress. SCLK clocks the data out at this register at any time after the conversion is complete. After SSTRB goes high, the next falling clock edge produces the MSB of the conversion at DOUT, fol- Maxim Integrated │  14 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface CS SCLK 1 DIN 2 3 4 SEL2 SEL1 SEL0 7 8 UNI/ SGL/ BIP DIF PD1 PD0 5 6 9 10 11 12 18 19 20 21 22 23 24 START SSTRB tCONV B11 MSB B10 DOUT ADC STATE ACQUISITION CONVERSION 1.5s 10s MAX (SCLK = 2MHz) IDLE B9 B2 B1 FILLED WITH B0 LSB ZEROS IDLE Figure 9. Internal Clock Mode Timing CS • • • tCONV tCSH tCSS tSCK SSTRB • • • tSSTRB SCLK • • • PD0 CLOCK IN NOTE: KEEP SCLK LOW DURING CONVERSION FOR BEST NOISE PERFORMANCE. Figure 10. Internal Clock Mode SSTRB Detailed Timing lowed by the remaining bits in MSB-first format (Figure 9). CS does not need to be held low once a conversion is started. Pulling CS high prevents data from being clocked into the MAX1202/MAX1203 and three-states DOUT, but it does not adversely affect an internal clock mode conversion already in progress. When internal clock mode is selected, SSTRB does not go into a high-impedance state when CS goes high. Figure 10 shows SSTRB timing in internal clock mode. Data can be shifted in and out of the MAX1202/MAX1203 at clock rates up to 2.0MHz, if tACQ is kept above 1.5μs. Data Framing CS’s falling edge does not start a conversion on the MAX1202/MAX1203. The first logic high clocked into www.maximintegrated.com DIN is interpreted as a start bit and defines the first bit of the control byte. A conversion starts on SCLK’s falling edge after the eighth bit of the control byte (the PD0 bit) is clocked into DIN. The start bit is defined as one of the following: The first high bit clocked into DIN with CS low anytime the converter is idle (e.g., after VDD is applied). or The first high bit clocked into DIN after bit 5 (B5) of a conversion in progress appears at DOUT. If a falling edge on CS forces a start bit before B5 becomes available, the current conversion is terminated and a new one started. Thus, the fastest the MAX1202/ MAX1203 can run is 15 clocks/conversion. Maxim Integrated │  15 MAX1202/MAX1203 Figure 11a shows the serial-interface timing necessary to perform a conversion every 15 SCLK cycles in external clock mode. If CS is low and SCLK is continuous, guarantee a start bit by first clocking in 16 zeros. Most microcontrollers (μCs) require that data transfers occur in multiples of eight clock cycles; 16 clocks per conversion is typically the fastest that a μC can drive the MAX1202/MAX1203. Figure 11b shows the serialinterface timing necessary to perform a conversion every 16 SCLK cycles in external clock mode. Applications Information Power-On Reset When power is first applied and if SHDN is not pulled low, internal power-on reset circuitry activates the MAX1202/ MAX1203 in internal clock mode, ready to convert with SSTRB = high. After the power supplies are stabilized, the internal reset time is 100μs. No conversions should be performed during this phase. SSTRB is high on power-up, and if CS is low, the first logical 1 on DIN is interpreted as a start bit. Until a conversion takes place, DOUT shifts out zeros. Reference-Buffer Compensation In addition to its shutdown function, SHDN also selects internal or external compensation. The compensation affects both power-up time and maximum conversion speed. Compensated or not, the minimum clock rate is 100kHz due to droop on the sample-and-hold. Leave SHDN unconnected to select external compensation. The Typical Operating Circuit uses a 4.7μF capacitor at REF. A value of 4.7μF or greater ensures stability and allows converter operation at the 2MHz full clock speed. External compensation increases power-up time (see the section Choosing Power-Down Mode, and Table 5). Internal compensation requires no external capacitor at REF, and is selected by pulling SHDN high. Internal compensation allows for the shortest power-up times, but the external clock must be limited to 400kHz during the conversion. Power-Down Choosing Power-Down Mode You can save power by placing the converter in a lowcurrent shutdown state between conversions. Select full power-down or fast power-down mode via bits 1 and 0 of the DIN control byte with SHDN high or unconnected (Tables 2 and 6). Pull SHDN low at any time to shut down the converter completely. SHDN overrides bits 1 and 0 of the control byte. www.maximintegrated.com 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Full power-down mode turns off all chip functions that draw quiescent current, reducing IDD and ISS typically to 2μA. For the MAX1202, fast power-down mode turns off all circuitry except the bandgap reference. With fast powerdown mode, the supply current is 30μA. Power-up time can be shortened to 5μs in internal compensation mode. Since the MAX1203 does not have an internal reference, power-up times coming out of full or fast power-down are identical. IDD shutdown current can increase if any digital input (DIN, SCLK, CS) is held high in either power-down mode. The actual shutdown current depends on the state of the digital inputs, the voltage applied to the digital inputs (VIH), the supply voltage (VDD), and the operating temperature. Figure 12c shows the maximum IDD increase for each digital input held high in power-down mode for different operating conditions. This current is cumulative, so if all three digital inputs are held high, the additional shutdown current is three times the value shown in Figure 12c. In both software power-down modes, the serial interface remains operational, but the ADC does not convert. Table 5 shows how the choice of reference-buffer compensation and power-down mode affects both power-up delay and maximum sample rate. In external compensation mode, power-up time is 20ms with a 4.7μF compensation capacitor (200ms with a 33μF capacitor) when the capacitor is initially fully discharged. From fast powerdown, start-up time can be eliminated by using lowleakage capacitors that do not discharge more than 1/2 LSB while shut down. In power-down, the capacitor has to supply the current into the reference (typically 1.5μA) and the transient currents at power-up. Figures 12a and 12b show the various power-down sequences in both external and internal clock modes. Software Power-Down Software power-down is activated using bits PD1 and PD0 of the control byte. As shown in Table 6, PD1 and PD0 also specify the clock mode. When software powerdown is asserted, the ADC continues to operate in the last specified clock mode until the conversion is complete. The ADC then powers down into a low quiescent-current state. In internal clock mode, the interface remains active and conversion results can be clocked out even though the MAX1202/MAX1203 have already entered software power-down. The first logical 1 on DIN is interpreted as a start bit and powers up the MAX1202/MAX1203. Following the start bit, the control byte also determines clock and power- Maxim Integrated │  16 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface CS 1 8 1 8 1 SCLK DIN S S CONTROL BYTE 0 DOUT B11 B10 B9 B8 S CONTROL BYTE 1 B7 B6 B5 B4 B3 B2 B1 B0 B11 B10 B9 B8 B7 B6 CONTROL BYTE 2 B5 B4 B3 B2 B1 B0 CONVERSION RESULT 1 CONVERSION RESULT 0 SSTRB Figure 11a. External Clock Mode, 15 Clocks/Conversion Timing CS ••• SCLK ••• DIN S S CONTROL BYTE 0 DOUT B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 CONVERSION RESULT 0 ••• CONTROL BYTE 1 B11 B10 B9 B8 B7 B6 B5 ••• CONVERSION RESULT 1 Figure 11b. External Clock Mode, 16 Clocks/Conversion Timing down modes. For example, if the DIN word contains PD1 = 1, the chip remains powered up. If PD1 = 0, power-down resumes after one conversion. Hardware Power-Down The SHDN pin places the converter into full power-down mode. Unlike the software power-down modes, conversion is not completed; it stops coincidentally with SHDN being brought low. There is no power-up delay if an external reference, which is not shut down, is used. SHDN also selects internal or external reference compensation (Table 7). Power-Down Sequencing The MAX1202/MAX1203’s automatic power-down modes can save considerable power when operating at less than maximum sample rates. The following sections discuss the various power-down sequences. this example) are required for the reference buffer to settle. When exiting FULLPD, waiting this 2ms in FASTPD mode (instead of just exiting FULLPD mode and returning to normal operating mode) reduces power consumption by a factor of 10 or more (Figure 13). Lowest Power at Higher Throughputs Figure 14b shows power consumption with external reference compensation in fast power-down, with one and eight channels converted. The external 4.7μF compensation requires a 50μs wait after power-up. This circuit combines fast multichannel conversion with the lowest power consumption possible. Full power-down mode can increase power savings in applications where the MAX1202/MAX1203 are inactive for long periods of time, but where intermittent bursts of high-speed conversion are required. Lowest Power at up to 500 Conversions per Channel per Second Figure 14a depicts MAX1202 power consumption for one or eight channel conversions using full power-down mode and internal reference compensation. A 0.01μF bypass capacitor at REFADJ forms an RC filter with the internal 20kΩ reference resistor, with a 0.2ms time constant. To achieve full 12-bit accuracy, 10 time constants (or 2ms in www.maximintegrated.com Maxim Integrated │  17 MAX1202/MAX1203 CLOCK MODE 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface INTERNAL EXTERNAL EXTERNAL SHDN SETS FAST POWER-DOWN MODE SETS EXTERNAL CLOCK MODE DIN S X X X X X 1 1 SETS EXTERNAL CLOCK MODE SX X XX X 0 1 DOUT DATA VALID (12 DATA BITS) MODE POWERED UP S XX XXX 1 1 DATA VALID (12 DATA BITS) DATA INVALID FAST POWER-DOWN FULL POWERDOWN POWERED UP POWERED UP Figure 12a. Timing Diagram for Power-Down Modes, External Clock Table 5. Typical Power-Up Delay Times REFERENCE BUFFER REFERENCE-BUFFER COMPENSATION MODE REF CAPACITOR (µF) POWER-DOWN MODE POWER-UP DELAY (µs) MAXIMUM SAMPLING RATE (ksps) Enabled Internal — Enabled Internal — Fast 5 26 Full 300 Enabled External 26 4.7 Fast/Full See Figure 14c 133 Disabled Disabled — — Fast 2 133 — — Full 2 133 Table 6. Software Shutdown and Clock Mode PD1 PD0 DEVICE MODE 0 0 Full power-down mode 0 1 Fast power-down mode 1 0 Internal clock mode 1 1 External clock mode www.maximintegrated.com Table 7. Hard-Wired Shutdown and Compensation Mode SHDN STATE DEVICE MODE REFERENCE-BUFFER COMPENSATION VDD Enabled Internal compensation Unconnected Enabled External compensation GND Full power-down N/A Maxim Integrated │  18 MAX1202/MAX1203 CLOCK MODE 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface INTERNAL CLOCK MODE SETS FULL POWER-DOWN SETS INTERNAL CLOCK MODE DIN S X X X X X 1 0 SX X XX X 0 0 DOUT S DATA VALID DATA VALID CONVERSION SSTRB CONVERSION FULL POWER-DOWN POWERED UP MODE POWERED UP Figure 12b. Timing Diagram for Power-Down Modes, Internal Clock External and Internal References 40 The MAX1202 can be used with an internal or external reference, whereas an external reference is required for the MAX1203. An external reference can be connected directly at the REF terminal, or at the REFADJ pin. SUPPLY CURRENT PER INPUT (mA) 35 (VDD - VIH) = 2.55V 30 25 An internal buffer is designed to provide 4.096V at REF for both the MAX1202 and the MAX1203. The MAX1202’s internally trimmed 2.44V reference is buffered with a gain of 1.68. The MAX1203’s REFADJ pin is buffered with a gain of 1.64, to scale an external 2.5V reference at REFADJ to 4.096V at REF. 20 15 (VDD - VIH) = 2.25V 10 (VDD - VIH) = 1.95V 5 MAX1202 Internal Reference 0 -60 -20 20 60 100 140 TEMPERATURE (°C) Figure 12c. Additional IDD Shutdown Supply Current vs. VIH for Each Digital Input at a Logic 1 The MAX1202’s full-scale range using the internal reference is 4.096V with unipolar inputs and ±2.048V with bipolar inputs. The internal reference voltage is adjustable to ±1.5% with the circuit of Figure 17. COMPLETE CONVERSION SEQUENCE DIN 1 00 FULLPD REFADJ (ZEROS) 2ms WAIT 1 01 FASTPD CH1 1 (ZEROS) CH7 11 NOPD 1 00 FULLPD 1 01 FASTPD 2.5V 0V REF 4V t = RC = 20kW x CREFADJ 0V tBUFFEN ª 15µs Figure 13. MAX1202 FULLPD/FASTPD Power-Up Sequence www.maximintegrated.com Maxim Integrated │  19 MAX1202/MAX1203 MAX1202/MAX1203 FAST POWER-DOWN 8 CHANNELS 100 1 CHANNEL 10 1 0 50 100 150 200 250 300 350 400 450 500 10,000 AVERAGE SUPPLY CURRENT (µA) 2ms FASTPD WAIT 400kHz EXTERNAL CLOCK INTERNAL COMPENSATION MAX186-14A FULL POWER-DOWN 1000 AVERAGE SUPPLY CURRENT (µA) 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface 8 CHANNELS 1000 100 10 CONVERSIONS PER CHANNEL PER SECOND Figure 14a. MAX1202 Supply Current vs. Sample Rate/ Second, FULLPD, 400kHz Clock 1 CHANNEL 2MHz EXTERNAL CLOCK EXTERNAL COMPENSATION 50µs WAIT 0 2k 4k 6k 8k 10k 12k 14k 16k 18k CONVERSIONS PER CHANNEL PER SECOND Figure 14b. MAX1202/MAX1203 Supply Current vs. Sample Rate/Second, FASTPD, 2MHz Clock External Reference Using the buffered REFADJ input makes buffering of the external reference unnecessary. When connecting an external reference directly at REF, disable the internal buffer by tying REFADJ to VDD. In power-down, the input bias current to REFADJ can be as much as 25μA with REFADJ tied to VDD (MAX1202 only). Pull REFADJ to GND to minimize the input bias current in power-down. Transfer Function and Gain Adjust Figure 15 depicts the nominal, unipolar input/output (I/O) transfer function, and Figure 16 shows the bipolar I/O transfer function. Code transitions occur halfway between successive-integer LSB values. Output coding is binary with 1 LSB = 1.00mV (4.096V/4096) for unipolar operation, and 1 LSB = 1.00mV [(4.096V/2 - -4.096V/2)/4096] for bipolar operation. Figure 17 shows how to adjust the ADC gain in applications that use the internal reference. The circuit provides ±1.5% (±65 LSBs) of gain adjustment range. www.maximintegrated.com 3.0 2.5 POWER-UP DELAY (ms) With both the MAX1202 and MAX1203, an external reference can be placed at either the input (REFADJ) or the output (REF) of the internal reference-buffer amplifier. The REFADJ input impedance is typically 20kΩ for the MAX1202, and higher than 100kΩ for the MAX1203, where the internal reference is omitted. At REF, the DC input resistance is a minimum of 12kΩ. During conversion, an external reference at REF must deliver up to 350μA DC load current and have an output impedance of 10Ω or less. If the reference has higher output impedance or is noisy, bypass it close to the REF pin with a 4.7μF capacitor. 2.0 1.5 1.0 0.5 0 0.0001 0.001 0.01 0.1 1 10 TIME IN SHUTDOWN (sec) Figure 14c. Typical Power-Up Delay vs. Time in Shutdown Layout, Grounding, and Bypassing For best performance, use printed circuit boards. Wirewrap boards are not recommended. Board layout should ensure that digital and analog signal lines are separated from each other. Do not run analog and digital (especially clock) lines parallel to one another, or digital lines underneath the ADC package. Figure 18 shows the recommended system ground connections. Establish a single-point analog ground Maxim Integrated │  20 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface OUTPUT CODE OUTPUT CODE FULL-SCALE TRANSITION 11 . . . 111 011 . . . 111 11 . . . 110 FS = +2.048V 011 . . . 110 1LSB = +4.096V 4096 11 . . . 101 000 . . . 010 000 . . . 001 FS = +4.096V 1LSB = + 4.096V 4096 111 . . . 111 111 . . . 110 111 . . . 101 00 . . . 011 00 . . . 010 100 . . . 001 00 . . . 001 00 . . . 000 000 . . . 000 100 . . . 000 0 1 2 3 INPUT VOLTAGE (LSBs) FS (“star” ground point) at GND. Connect all other analog grounds to this ground. No other digital system ground should be connected to this single-point analog ground. The ground return to the power supply for this ground should be low impedance and as short as possible for noise-free operation. High-frequency noise in the power supplies can affect the ADC’s high-speed comparator. Bypass these supplies to the single-point analog ground with 0.1μF and 4.7μF bypass capacitors close to the MAX1202/MAX1203. Minimize capacitor lead lengths for best supply-noise rejection. If the +5V power supply is very noisy, a 10Ω resistor can be connected as a lowpass filter, as shown in Figure 18. +FS - 1LSB INPUT VOLTAGE (LSBs) FS - 3/2LSB Figure 15. Unipolar Transfer Function, 4.096V = Full Scale www.maximintegrated.com 0V -FS Figure 16. Bipolar Transfer Function, ±4.096V/2 = Full Scale +5V MAX1202 510kΩ 100kΩ 12 24kΩ REFADJ 0.01µF Figure 17. MAX1202 Reference-Adjust Circuit Maxim Integrated │  21 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface TMS320CL3x to MAX1202/ MAX1203 Interface 3) Write an 8-bit word (1XXXXX11) to the MAX1202/ MAX1203 to initiate a conversion and place the device into external clock mode. Refer to Table 2 to select the proper XXXXX bit values for your specific application. Figure 19 shows an application circuit to interface the MAX1202/MAX1203 to the TMS320 in external clock mode. Figure 20 shows the timing diagram for this interface circuit. 4) The MAX1202/MAX1203’s SSTRB output is monitored via the TMS320’s FSR input. A falling edge on the SSTRB output indicates that the conversion is in progress and data is ready to be received from the MAX1202/MAX1203. Use the following steps to initiate a conversion in the MAX1202/MAX1203 and to read the results: 1) The TMS320 should be configured with CLKX (transmit clock) as an active-high output clock and CLKR (TMS320 receive clock) as an active-high input clock. The TMS320’s CLKX and CLKR are tied together with the MAX1202/MAX1203’s SCLK input. 5) The TMS320 reads in one data bit on each of the next 16 rising edges of SCLK. These data bits represent the 12-bit conversion result followed by four trailing bits, which should be ignored. 6) Pull CS high to disable the MAX1202/MAX1203 until the next conversion is initiated. 2) The MAX1202/MAX1203’s CS is driven low by the TMS320’s XF_ I/O port to enable data to be clocked into the MAX1202/MAX1203’s DIN. SUPPLIES +5V -5V +3V GND XF CS CLKX R* = 10Ω VDD SCLK TMS320LC3x MAX1202 MAX1203 CLKR GND VSS VL MAX1202 MAX1203 +3V DGND DIGITAL CIRCUITRY DX DIN DR DOUT FSR SSTRB *OPTIONAL Figure 18. Power-Supply Grounding Connection Figure 19. MAX1202/MAX1203-to-TMS320 Serial Interface CS SCLK DIN START SEL2 SEL1 SEL0 UNI/BIP SGL/DIF PD1 PD0 HIGH IMPEDANCE SSTRB DOUT MSB B10 B1 LSB HIGH IMPEDANCE Figure 20. TMS320 Serial-Interface Timing Diagram www.maximintegrated.com Maxim Integrated │  22 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Chip Information Ordering Information (continued) INL (LSB) ±1/2 PROCESS: BiCMOS PART TEMP RANGE MAX1202AEPP+ -40ºC to +85ºC PINPACKAGE 20 PDIP MAX1202BEPP+ -40ºC to +85ºC 20 PDIP ±1 MAX1202AEAP+ -40ºC to +85ºC 20 SSOP ±1/2 MAX1202BEAP+ -40ºC to +85ºC 20 SSOP ±1 MAX1203ACPP+ 0ºC to +70ºC 20 PDIP ±1/2 MAX1203BCPP+ 0ºC to +70ºC 20 PDIP ±1 MAX1203ACAP+ 0ºC to +70ºC 20 SSOP ±1/2 PACKAGE TYPE PACKAGE CODE MAX1203BCAP+ 0ºC to +70ºC 20 SSOP ±1 20 SSOP A20+2 21-0056 90-0094 MAX1203AEPP+ -40ºC to +85ºC 20 PDIP ±1/2 20 PDIP P20+3 21-0043 — MAX1203BEPP+ -40ºC to +85ºC 20 PDIP ±1 MAX1203AEAP+ -40ºC to +85ºC 20 SSOP ±1/2 MAX1203BEAP+ -40ºC to +85ºC 20 SSOP ±1 Package Information For the latest package outline information and land patterns (footprints), go to www.maximintegrated.com/packages. Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a different suffix character, but the drawing pertains to the package regardless of RoHS status. DOCUMENT LAND NO. PATTERN NO. +Denotes a lead(Pb)-free/RoHS-compliant package. Typical Operating Circuit +5V CH0 0 to 4.096V ANALOG INPUTS MAX1202 REF SCLK DIN DOUT REFADJ C3 0.1µF C4 4.7µF C5 0.1µF CPU GND VSS CS C2 0.01µF VDD VL CH7 C1 4.7µF +3V VDD SSTRB SHDN www.maximintegrated.com I/O SCK (SK) MOSI (SO) MISO (SI) VSS Maxim Integrated │  23 MAX1202/MAX1203 5V, 8-Channel, Serial, 12-Bit ADCs with 3V Digital Interface Package Information REVISION NUMBER REVISION DATE PAGES CHANGED 0 1/97 Initial release 1 3/97 Added MAX1203 to the data sheet 1–24 2 5/98 Corrected gain error limit 2, 20 3 3/12 Removed military grade packages and updated style throughout data sheet DESCRIPTION — 1–10, 13, 16, 18, 22, 23 For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642, or visit Maxim Integrated’s website at www.maximintegrated.com. Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametric values (min and max limits) shown in the Electrical Characteristics table are guaranteed. Other parametric values quoted in this data sheet are provided for guidance. Maxim Integrated and the Maxim Integrated logo are trademarks of Maxim Integrated Products, Inc. ©  2012 Maxim Integrated Products, Inc. │  24
MAX1202ACPP+ 价格&库存

很抱歉,暂时无法提供与“MAX1202ACPP+”相匹配的价格&库存,您可以联系我们找货

免费人工找货