0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CDSOT23-T24CAN

CDSOT23-T24CAN

  • 厂商:

    BOURNS(伯恩斯)

  • 封装:

    SOT-23

  • 描述:

    ESD 抑制器/TVS 二极管 SOT23-3

  • 数据手册
  • 价格&库存
CDSOT23-T24CAN 数据手册
T PL IA N M CO *R oH S C 28 01L Features Applications ■ Single device for two I/O lines ■ High-speed CANbus ■ Low capacitance for high-speed CANbus ■ Industrial control networks ■ IEC 61000-4-2 30 kV ESD ■ Smart Distribution Systems (SDS) ■ IEC 61000-4-5 (Level 1, CWG 1.2/50) ■ DeviceNet™ 500 V Surge ■ RoHS compliant* ■ Factory and process automation systems ■ Lift control systems CDSOT23-T24CAN CANbus Protector General Information The Model CDSOT23-T24CAN device is designed to provide ESD and surge protection for CAN transceivers, meeting IEC 61000-4-2 (ESD) and IEC 61000-4-5 (Surge) requirements. The dual TVS array protects both data lines, offers a Working Reverse Voltage of 24 V and a Minimum Breakdown Voltage of 26.2 V and can be used with transceivers with internal circuitry for 24 V power supply miswiring. The low capacitance and low leakage current of the Model CDSOT23-T24CAN minimizes impact on signal integrity and is compatible with high-speed CAN. 1 3 2 The SOT-23 packaged device conforms to JEDEC standards and will mount directly onto the industry standard SOT-23 footprint. Its compact size eases layout on compact PCB designs while ensuring compliance with stringent EMI requirements. Absolute Maximum Ratings (@ TA = 25 °C Unless Otherwise Noted) Rating Symbol Value Unit Repetitive Peak Off-state Voltage VDRM 24 V Non-Repetitive Peak Impulse Current, 8/20 μs Waveform IPPSM 8 A Non-Repetitive Peak Impulse Current, 1.2/50 μs Waveform IPPSM 6 A 30 kV ESD (IEC 61000-4-2 Contact) Junction Temperature TJ -40 to +150 ˚C Storage Temperature Tstg -55 to +150 ˚C Electrical Characteristics (@ TA = 25 °C Unless Otherwise Noted) Parameter Test Condition Leakage Current VD = VDRM Breakdown Voltage IBR = 1 mA VC Clamping Voltage I = 5 A 8/20 μs waveform 36 V VC Clamping voltage I = 8 A 8/20 μs waveform 40 V Capacitance VD = 0 V, f = 1 MHz Vosc = 1 Vrms ID VBR C Min. Typ. 26.2 Line to GND (Pin 1-3 or Pin 2-3) 22 Line to Line (Pin 1-2) 11 Max. Unit 100 nA 32 V 30 pF WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov DeviceNet™ is a trademark of ODVA. *RoHS Directive 2015/863, Mar 31, 2015 and Annex. Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf. CDSOT23-T24CAN CANbus Protector Rating & Characteristic Curves 8/20 μs Pulse Waveform Clamping Voltage vs. Peak Pulse Current 100 10 Test Waveform Parameters tt = 8 µs td = 20 µs tt 80 et 60 40 td = t|IPP/2 20 0 0 5 10 15 20 25 8/20 µs Waveform 8 IPP - Peak Pulse Current (A) IPP – Peak Pulse Current (% of IPP) 120 6 4 2 30 t – Time (µs) 0 25 Leakage Current vs. Temperature 30 35 VC - Clamping Voltage (V) 40 45 Breakdown Voltage vs. Temperature 10 32 VBR - Typical Breakdown Voltage (V) ID - Typical Leakage Current (nA) 31 VD = 24 V 1 0.1 0.01 -60 -30 0 30 60 Temperature (°C) 90 120 150 30 29 28 27 26 -60 -30 0 30 60 Temperature (°C) 90 120 150 Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf. CDSOT23-T24CAN CANbus Protector Application Information The Model CDSOT23-T24CAN dual TVS diode array is designed to protect a CANbus transceiver against surge events per IEC 61000-4-5 (Level 1), and also increase the resistibility against ESD events beyond IEC 61000-4-2 to as high as 30 kV. It is intended to be used with a transceiver that has internal protection against other faults such as 24 V power supply miswiring. The Model CDSOT23-T24CAN is designed with a minimum breakdown voltage of 26.2 V so that it will not conduct during a 24 VDC power cross event. The surge test setup below shows the differential input/output (I/O) of a typical transceiver, its termination network, being protected by the CDSOT23-T24CAN device. The 1.2/50 μs voltage, 8/20 μs current combination wave generator is connected to the circuit through two 80 ohm resistors and a coupling device (CD). This circuit was subjected to a 500 V (1.2/50) longitudinal surge (common mode) in both positive and negative polarities per IEC 61000-4-5 (Level 1). The oscilloscope traces in Figures 1 and 2 show the clamp voltage with respect to ground for the CAN H and CAN L signal lines, as well as the total surge current output from the surge generator into the circuit, for each of these surges. The peak current on each line is ~ 5.5 A (11 A total/2 lines) when subjected to the 500 V (1.2/50) surge. The TVS diode clamps the voltage at the I/O of the transceiver within 37 V during the surge. CD CD CANbus Transceiver Figure 1 CDSOT23-T24CAN Clamp Voltages for a +500 V Surge Figure 2 CDSOT23-T24CAN Clamp Voltages for a -500 V Surge Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf. CDSOT23-T24CAN CANbus Protector Layout Considerations The figure below shows an example of how the Model CDSOT23-T24CAN can be connected on a two-sided PCB design. The device should be placed as close to the bus connector as possible with short traces to the signal lines. Since the connector pin spacing is generally much larger than the pin spacing of the transceiver, it is relatively easy to do this. A standard 10 mil, 1 ounce copper trace is more than adequate to handle the peak current level from the 500 V surge discussed in the previous section. The ground pin of the device should be connected to the circuit board ground plane using a short trace and a via. If there is a ground plane on the signal side of the circuit board near where the diode array is placed, it should be connected directly to it. Typical Part Marking Environmental Specifications 2-DIGIT PRODUCT CODE C2YWWL Moisture Sensitivity Level ................................................................1 ESD Classification (HBM)............................................................. 3B MANUFACTURING DATE CODE: Y = YEAR WW = WEEK L = LOT CODE Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf. CDSOT23-T24CAN CANbus Protector Product Dimensions Recommended Footprint A A 3 C 1 B DIMENSIONS = MILLIMETERS (INCHES) B SEE DETAIL D A 2 C E F DETAIL A GAUGE PLANE E L H G D SEATING PLANE I 0 ° TO 8 ° DIMENSIONS = MILLIMETERS (INCHES) J Dimensions K A 2.80 - 3.00 (0.110 - 0.118) B 0.95 (0.037) BSC A 0.95 (0.037) C 1.20 - 1.40 (0.047 - 0.055) B 0.95 (0.037) D 2.10 - 2.49 (0.083 - 0.098) C E 1.90 (0.075) BSC 2.00 (0.079) D F 0.30 - 0.50 (0.012 - 0.019) 0.85 (0.033) E G 0.89 - 1.17 (0.035 - 0.046) 0.85 (0.033) H 0.05 - 0.15 (0.002 - 0.006) I 0.25 (0.010) BSC J 0.46 - 0.64 (0.018 - 0.025) K 0.40 - 0.58 (0.016 - 0.023) L 0.08 - 0.20 (0.003 - 0.008) Dimensions How to Order CD SOT23 - T 24 CAN Common Code Chip Diode Package SOT23 = SOT-23-3L Package Model T = Transient Voltage Suppressor Working Reverse Voltage 24 = 24 V Suffix CAN = CANbus Protector Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf. CDSOT23-T24CAN CANbus Protector Packaging Information The product is dispensed in tape and reel format (see diagram below). P 0 P 1 d T E Index Hole 120 ϒ F D2 W B D1 D P A C Trailer Device Leader ....... ....... ....... ....... ....... ....... ....... ....... End W1 Start DIMENSIONS: 10 pitches (min.) 10 pitches (min.) Direction of Feed Item Symbol SOT-23 Carrier Width A 2.25 ±0.10 (0.088 - 0.004) Carrier Length B 2.34 ±0.10 (0.092 - 0.004) Carrier Depth C 1.22 ±0.10 (0.048 - 0.004) Sprocket Hole d 1.55 ±0.05 (0.061 - 0.002) Reel Outside Diameter D 178 (7.008) Reel Inner Diameter D1 ... 50.0 Min. (1.969) Feed Hole Diameter D2 13.0 ± 0.20 (0.512 ± 0.008) Sprocket Hole Position E 1.75 ± 0.10 (0.069 ± 0.004) Punch Hole Position F 3.50 ± 0.05 (0.138 ± 0.002) Punch Hole Pitch P 4.00 ±0.10 (0.157 - 0.004) Sprocket Hole Pitch P0 4.00 ± 0.10 (0.157 ± 0.004) Embossment Center P1 2.00 ± 0.05 (0.079 ± 0.002) Overall Tape Thickness T 0.20 ± 0.10 (0.008 ± 0.004) Tape Width W 8.00 ±0.20 (0.315 - 0.008) Reel Width W1 . 14.4 Max. (0.567) -- 3,000 Quantity per Reel MM (INCHES) Devices are packed in accordance with EIA standard RS-481-A. Asia-Pacific: Tel: +886-2 2562-4117 Email: asiacus@bourns.com Europe: Tel: +36 88 885 877 Email: eurocus@bourns.com The Americas: Tel: +1-951 781-5500 Email: americus@bourns.com www.bourns.com REV. 08/19 Specifications are subject to change without notice. Users should verify actual device performance in their specific applications. The products described herein and this document are subject to specific legal disclaimers as set forth on the last page of this document, and at www.bourns.com/docs/legal/disclaimer.pdf. Legal Disclaimer Notice This legal disclaimer applies to purchasers and users of Bourns® products manufactured by or on behalf of Bourns, Inc. and P[ZHɉSPH[LZJVSSLJ[P]LS`¸)V\YUZ¹ Unless otherwise expressly indicated in writing, Bourns® products and data sheets relating thereto are subject to change ^P[OV\[UV[PJL
CDSOT23-T24CAN 价格&库存

很抱歉,暂时无法提供与“CDSOT23-T24CAN”相匹配的价格&库存,您可以联系我们找货

免费人工找货