BQ40Z50RSMT

BQ40Z50RSMT

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    VQFN-32_4X4MM-EP

  • 描述:

    IC BATT MFUNC LI-ION 1-4C 32VQFN

  • 数据手册
  • 价格&库存
BQ40Z50RSMT 数据手册
Product Folder Order Now Support & Community Tools & Software Technical Documents BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 BQ40Z50 1-Series, 2-Series, 3-Series, and 4-Series Li-Ion Battery Pack Manager 1 Features 3 Description • The BQ40Z50 device, incorporating patented Impedance Track™ technology, is a fully integrated, single-chip, pack-based solution that provides a rich array of features for gas gauging, protection, and authentication for 1-series, 2-series, 3-series, and 4series cell Li-Ion and Li-Polymer battery packs. • • • • 2 Applications • • • BQ40Z50 PACKAGE BODY SIZE (NOM) VQFN (32) 4.00 mm × 4.00 mm (1) For all available packages, see the orderable addendum at the end of the data sheet. Simplified Schematic VC4 DSG PACK BAT VCC PACK + CHG • • • PART NUMBER PCHG • Device Information(1) PTC • Using its integrated high-performance analog peripherals, the BQ40Z50 device measures and maintains an accurate record of available capacity, voltage, current, temperature, and other critical parameters in Li-Ion or Li-Polymer batteries, and reports this information to the system host controller over an SMBus v1.1 compatible interface. FUSE • • LEDCNTLA LEDCNTLB LEDCNTLC VC3 OUT VDD GND VC3 nd • Fully Integrated 1-Series, 2-Series, 3-Series, and 4-Series Li-Ion or Li-Polymer Cell Battery Pack Manager and Protection Next-Generation Patented Impedance Track™ Technology Accurately Measures Available Charge in Li-Ion and Li-Polymer Batteries High Side N-CH Protection FET Drive Integrated Cell Balancing While Charging or At Rest Full Array of Programmable Protection Features – Voltage – Current – Temperature – Charge Timeout – CHG/DSG FETs – AFE Sophisticated Charge Algorithms – JEITA – Enhanced Charging – Adaptive Charging – Cell Balancing Supports TURBO BOOST Mode Supports Battery Trip Point (BTP) Diagnostic Lifetime Data Monitor and Black Box Recorder LED Display Supports Two-Wire SMBus v1.1 Interface SHA-1 Authentication Compact Package: 32-Lead QFN (RSM) 2 level protector 1 VC2 Cell 3 VC2 DISP Cell 2 VC1 SMBD SMBC PBI VSS SRP SRN TS1 TS2 TS3 TS4 BTP PRES VC1 Cell 1 SMBD SMBC PRES BTP PACK– Copyright © 2017, Texas Instruments Incorporated Notebook/Netbook PCs Medical and Test Equipment Portable Instrumentation 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com Table of Contents 1 2 3 4 5 6 7 Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Description (continued)......................................... Pin Configuration and Functions ......................... Specifications......................................................... 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.25 Electrical Characteristics: High-Frequency Oscillator .................................................................. 14 7.26 Electrical Characteristics: Low-Frequency Oscillator .................................................................. 15 7.27 Electrical Characteristics: Voltage Reference 1.... 15 7.28 Electrical Characteristics: Voltage Reference 2.... 15 7.29 Electrical Characteristics: Instruction Flash .......... 15 7.30 Electrical Characteristics: Data Flash ................... 15 7.31 Electrical Characteristics: OCD, SCC, SCD1, SCD2 Current Protection Thresholds ................................. 16 7.32 Timing Requirements: OCD, SCC, SCD1, SCD2 Current Protection Timing ........................................ 17 7.33 Timing Requirements: SMBus .............................. 17 7.34 Timing Requirements: SMBus XL......................... 18 7.35 Typical Characteristics .......................................... 19 1 1 1 2 3 3 7 Absolute Maximum Ratings ...................................... 7 ESD Ratings.............................................................. 7 Recommended Operating Conditions....................... 8 Thermal Information .................................................. 8 Electrical Characteristics: Supply Current................. 8 Electrical Characteristics: Power Supply Control...... 9 Electrical Characteristics: AFE Power-On Reset ...... 9 Electrical Characteristics: AFE Watchdog Reset and Wake Timer................................................................ 9 7.9 Electrical Characteristics: Current Wake Comparator ................................................................ 9 7.10 Electrical Characteristics: VC1, VC2, VC3, VC4, BAT, PACK .............................................................. 10 7.11 Electrical Characteristics: SMBD, SMBC.............. 10 7.12 Electrical Characteristics: PRES, BTP_INT, DISP .................................................................................10 7.13 Electrical Characteristics: LEDCNTLA, LEDCNTLB, LEDCNTLC ............................................................. 11 7.14 Electrical Characteristics: Coulomb Counter ........ 11 7.15 Electrical Characteristics: CC Digital Filter ........... 11 7.16 Electrical Characteristics: ADC ............................. 12 7.17 Electrical Characteristics: ADC Digital Filter ......... 12 7.18 Electrical Characteristics: CHG, DSG FET Drive . 12 7.19 Electrical Characteristics: PCHG FET Drive ......... 13 7.20 Electrical Characteristics: FUSE Drive.................. 13 7.21 Electrical Characteristics: Internal Temperature Sensor...................................................................... 13 7.22 Electrical Characteristics: TS1, TS2, TS3, TS4 .... 14 7.23 Electrical Characteristics: PTC, PTCEN ............... 14 7.24 Electrical Characteristics: Internal 1.8-V LDO ..... 14 8 Detailed Description ............................................ 22 8.1 8.2 8.3 8.4 9 Overview ................................................................. Functional Block Diagram ...................................... Feature Description................................................. Device Functional Modes........................................ 22 22 23 26 Applications and Implementation ...................... 27 9.1 Application Information .......................................... 27 9.2 Typical Applications ................................................ 28 10 Power Supply Recommendations ..................... 42 11 Layout................................................................... 42 11.1 Layout Guidelines ................................................. 42 11.2 Layout Example .................................................... 44 12 Device and Documentation Support ................. 46 12.1 12.2 12.3 12.4 12.5 12.6 Documentation Support ........................................ Receiving Notification of Documentation Updates Support Resources ............................................... Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 46 46 46 46 46 46 13 Mechanical, Packaging, and Orderable Information ........................................................... 46 4 Revision History Changes from Revision A (July 2014) to Revision B • 2 Page Changed FUSE Circuitry ..................................................................................................................................................... 36 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 5 Description (continued) The BQ40Z50 device supports TURBO BOOST mode by providing the available max power and max current to the host system. The device also supports Battery Trip Point to send a BTP interrupt signal to the host system at the pre-set state of charge thresholds. The BQ40Z50 provides software-based 1st- and 2nd-level safety protection against overvoltage, undervoltage, overcurrent, short-circuit current, overload, and overtemperature conditions, as well as other pack- and cellrelated faults. SHA-1 authentication, with secure memory for authentication keys, enables identification of genuine battery packs. The compact 32-lead QFN package minimizes solution cost and size for smart batteries while providing maximum functionality and safety for battery gauging applications. 6 Pin Configuration and Functions BAT CHG PCHG NC DSG PACK VCC FUSE 32 31 30 29 28 27 26 25 RSM Package 32-Pin VQFN with Exposed Thermal Pad Top View PBI 1 24 PTCEN VC4 2 23 PTC VC3 3 22 LEDCNTLC VC2 4 21 LEDCNTLB VC1 5 20 LEDCNTLA SRN 6 19 SMBC NC 7 18 SMBD SRP 8 17 DISP Thermal 13 14 15 16 TS4 NC BTP_INT PRES_or_SHUTDN 11 TS2 12 10 TS1 TS3 9 VSS Pad Pin Functions PIN NAME NUMBER TYPE DESCRIPTION PBI 1 P (1) VC4 2 IA Sense voltage input pin for most positive cell, and balance current input for most positive cell VC3 3 IA Sense voltage input pin for second most positive cell, balance current input for second most positive cell, and return balance current for most positive cell (1) Power supply backup input pin P = Power Connection, O = Digital Output, AI = Analog Input, I = Digital Input, I/OD = Digital Input/Output Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 3 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com Pin Functions (continued) PIN NAME NUMBER TYPE DESCRIPTION VC2 4 IA Sense voltage input pin for third most positive cell, balance current input for third most positive cell, and return balance current for second most positive cell VC1 5 IA Sense voltage input pin for least positive cell, balance current input for least positive cell, and return balance current for third most positive cell SRN 6 I NC 7 — SRP 8 I Analog input pin connected to the internal coulomb counter peripheral for integrating a small voltage between SRP and SRN where SRP is the top of the sense resistor. VSS 9 P Device ground TS1 10 IA Temperature sensor 1 thermistor input pin TS2 11 IA Temperature sensor 2 thermistor input pin TS3 12 IA Temperature sensor 3 thermistor input pin TS4 13 IA Temperature sensor 4 thermistor input pin NC 14 — Not internally connected BTP_INT 15 O Battery Trip Point (BTP) interrupt output PRES or SHUTDN 16 I Host system present input for removable battery pack or emergency system shutdown input for embedded pack DISP 17 — SMBD 18 I/OD SMBus data pin SMBC 19 I/OD SMBus clock pin LEDCNTLA 20 — LED display segment that drives the external LEDs depending on the firmware configuration LEDCNTLB 21 — LED display segment that drives the external LEDs depending on the firmware configuration LEDCNTLC 22 — LED display segment that drives the external LEDs depending on the firmware configuration PTC 23 IA Safety PTC thermistor input pin. To disable, connect both PTC and PTCEN to VSS. PTCEN 24 IA Safety PTC thermistor enable input pin. Connect to BAT. To disable, connect both PTC and PTCEN to VSS. FUSE 25 O Fuse drive output pin VCC 26 P Secondary power supply input PACK 27 IA Pack sense input pin DSG 28 O NMOS Discharge FET drive output pin NC 29 — Not internally connected PCHG 30 O PMOS Precharge FET drive output pin CHG 31 O NMOS Charge FET drive output pin BAT 32 P Primary power supply input pin 4 Analog input pin connected to the internal coulomb counter peripheral for integrating a small voltage between SRP and SRN where SRP is the top of the sense resistor. Not internally connected Display control for LEDs Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 VC4 BAT VCC CDEN4 PACK VC3 + – 3.1 V BATDET ENVCC CDEN3 PACK Detector VC2 PACKDET PBI Reference System Shutdown Latch 1.8 V Domain VC1 BAT Control Power Supply Control ADC CDEN2 SHOUT ENBAT ADC Mux SHUTDOWN CDEN1 Cell Balancing VCC CHGEN BAT 2 kΩ CHG Pump CHG 8 kΩ 2 kΩ PCHG CHGOFF PCHGEN Pre-Charge Drive PACK BAT DSGEN BAT DSG Pump ZVCD 2 kΩ DSG CHGEN BAT DSGOFF CHG Pump VCC ZVCHGEN CHG, DSG Drive Zero-Volt Charge Figure 1. Pin Equivalent Diagram 1 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 5 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com 1.8 V ADTHx BAT FUSEWKPUP 18 kΩ 2 kΩ ADC Mux TS1,2,3,4 ADC FUSEEN 150 nA 2 kΩ FUSE 1.8 V 1.8 V 100 kΩ FUSEDIG RCWKPUP RCPUP FUSE Drive 1 kΩ RCIN RCOUT 100 kΩ SMBCIN SMBC Thermistor Inputs SMBCOUT SMBCEN 1 MΩ PBI 100 kΩ SMBDIN RHOEN SMBD SMBDOUT 10 kΩ PRES SMBDEN 1 MΩ SMBus Interface RHOUT 100 kΩ RHIN High-Voltage GPIO BAT RLOEN LED1, 2, 3 22.5 mA RLOUT 100 kΩ RLIN LED Drive Figure 2. Pin Equivalent Diagram 2 6 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 10 Ω VC4 CHANx Φ2 3.8 kΩ 1.9 MΩ SRP ADC Mux Φ1 ADC Φ2 3.8 kΩ 0.1 MΩ SRN Comparator Array Φ1 Φ2 10 Ω 100 Ω PACK Φ1 Coulomb Counter Φ2 CHANx 100 Ω Φ1 1.9 MΩ ADC Mux ADC 0.1 MΩ OCD, SCC, SCD Comparators and Coulomb Counter VC4 and PACK Dividers Figure 3. Pin Equivalent Diagram 3 7 Specifications 7.1 Absolute Maximum Ratings Over-operating free-air temperature range (unless otherwise noted) (1) Supply voltage range, VCC Input voltage range, VIN Output voltage range, VO MIN MAX UNIT BAT, VCC, PBI –0.3 30 V PACK, SMBC, SMBD, PRES or SHUTDN, BTP_INT, DISP –0.3 30 V TS1, TS2, TS3, TS4 –0.3 VREG + 0.3 V PTC, PTCEN, LEDCNTLA, LEDCNTLB, LEDCNTLC –0.3 VBAT + 0.3 V SRP, SRN –0.3 0.3 V VC4 VC3 – 0.3 VC3 + 8.5, or VSS + 30 V VC3 VC2 – 0.3 VC2 + 8.5, or VSS + 30 V VC2 VC1 – 0.3 VC1 + 8.5, or VSS + 30 V VC1 VSS – 0.3 VSS + 8.5, or VSS + 30 V CHG, DSG –0.3 32 PCHG, FUSE –0.3 30 V 50 mA 150 °C 300 °C Maximum VSS current, ISS Storage temperature, TSTG –65 Lead temperature (soldering, 10 s), TSOLDER (1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability. 7.2 ESD Ratings VALUE V(ESD) (1) (2) Electrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001 (1) ±2000 Charged-device model (CDM), per JEDEC specification JESD22-C101 (2) ±500 UNIT V JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 7 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com 7.3 Recommended Operating Conditions Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) MIN VCC Supply voltage BAT, VCC, PBI VSHUTDOWN– Shutdown voltage VPACK < VSHUTDOWN– VSHUTDOWN+ Start-up voltage VPACK > VSHUTDOWN– + VHYS VHYS Shutdown voltage hysteresis VSHUTDOWN+ – VSHUTDOWN– NOM MAX 2.2 Input voltage range V 1.8 2.0 2.2 V 2.05 2.25 2.45 V 250 mV PACK, SMBC, SMBD, PRES, BTP_IN, DISP VIN UNIT 26 26 TS1, TS2, TS3, TS4 VREG PTC, PTCEN, LEDCNTLA, LEDCNTLB, LEDCNTLC VBAT SRP, SRN –0.2 0.2 VC4 VVC3 VVC3 + 5 VC3 VVC2 VVC2 + 5 VC2 VVC1 VVC1 + 5 VC1 VVSS VVSS + 5 VO Output voltage range CPBI External PBI capacitor 2.2 TOPR Operating temperature –40 CHG, DSG, PCHG, FUSE 26 V V µF 85 °C 7.4 Thermal Information BQ40Z50 THERMAL METRIC (1) RSM (QFN) UNIT 32 PINS RθJA, High K Junction-to-ambient thermal resistance 47.4 °C/W RθJC(top) Junction-to-case(top) thermal resistance 40.3 °C/W RθJB Junction-to-board thermal resistance 14.7 °C/W ψJT Junction-to-top characterization parameter 0.8 °C/W ψJB Junction-to-board characterization parameter 14.4 °C/W RθJC(bottom) Junction-to-case(bottom) thermal resistance 3.8 °C/W (1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report, SPRA953. 7.5 Electrical Characteristics: Supply Current Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 20 V (unless otherwise noted) PARAMETER INORMAL NORMAL mode ISLEEP SLEEP mode ISHUTDOWN SHUTDOWN mode 8 TEST CONDITIONS CHG on. DSG on, no Flash write MIN TYP 336 CHG off, DSG on, no SBS communication 75 CHG off, DSG off, no SBS communication 52 1.6 Submit Documentation Feedback MAX UNIT µA µA µA Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 7.6 Electrical Characteristics: Power Supply Control Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS VSWITCHOVER– BAT to VCC switchover voltage VBAT < VSWITCHOVER– VSWITCHOVER+ VCC to BAT switchover voltage VBAT > VSWITCHOVER– + VHYS VHYS Switchover VSWITCHOVER+ – VSWITCHOVER– voltage hysteresis ILKG RPD Input Leakage current Internal pulldown resistance MIN TYP MAX 1.95 2.1 2.2 V 2.9 3.1 3.25 V 1000 mV BAT pin, BAT = 0 V, VCC = 25 V, PACK = 25 V 1 PACK pin, BAT = 25 V, VCC = 0 V, PACK = 0 V 1 BAT and PACK terminals, BAT = 0 V, VCC = 0 V, PACK = 0 V, PBI = 25 V 1 PACK 30 40 UNIT 50 µA kΩ 7.7 Electrical Characteristics: AFE Power-On Reset Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS VREGIT– Negative-going voltage input VREG VHYS Power-on reset hysteresis VREGIT+ – VREGIT– tRST Power-on reset time MIN TYP MAX UNIT 1.51 1.55 1.59 V 70 100 130 mV 200 300 400 µs 7.8 Electrical Characteristics: AFE Watchdog Reset and Wake Timer Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX 372 500 628 tWDT = 1000 744 1000 1256 tWDT = 2000 1488 2000 2512 tWDT = 4000 2976 4000 5024 tWAKE = 250 186 250 314 tWAKE = 500 372 500 628 tWAKE = 1000 744 1000 1256 tWAKE = 512 1488 2000 2512 409 512 614 tWDT = 500 tWDT AFE watchdog timeout tWAKE AFE wake timer tFETOFF FET off delay after reset tFETOFF = 512 UNIT ms ms ms 7.9 Electrical Characteristics: Current Wake Comparator Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER VWAKE Wake voltage threshold TEST CONDITIONS MIN TYP MAX VWAKE = ±0.625 mV ±0.3 ±0.625 ±0.9 VWAKE = ±1.25 mV ±0.6 ±1.25 ±1.8 VWAKE = ±2.5 mV ±1.2 ±2.5 ±3.6 VWAKE = ±5 mV ±2.4 ±5.0 ±7.2 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 UNIT mV 9 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com Electrical Characteristics: Current Wake Comparator (continued) Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER VWAKE(DRIFT) Temperature drift of VWAKE accuracy tWAKE Time from application of current to wake interrupt tWAKE(SU) Wake comparator startup time TEST CONDITIONS MIN TYP MAX 0.5% 500 UNIT °C 700 µs 1000 µs 7.10 Electrical Characteristics: VC1, VC2, VC3, VC4, BAT, PACK Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX 0.1980 0.2000 0.2020 BAT–VSS, PACK–VSS 0.049 0.050 0.051 VREF2 0.490 0.500 0.510 VC1–VSS, VC2–VC1, VC3–VC2, VC4–VC3 K Scaling factor VC1–VSS, VC2–VC1, VC3–VC2, VC4–VC3 –0.2 5 BAT–VSS, PACK–VSS –0.2 20 VIN Input voltage range ILKG Input leakage current VC1, VC2, VC3, VC4, cell balancing off, cell detach detection off, ADC multiplexer off RCB Internal cell balance resistance RDS(ON) for internal FET switch at 2 V < VDS < 4 V ICD Internal cell detach check current VCx > VSS + 0.8 V 30 50 UNIT — V 1 µA 200 Ω 70 µA 7.11 Electrical Characteristics: SMBD, SMBC Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX VIH Input voltage high SMBC, SMBD, VREG = 1.8 V 1.3 VIL Input voltage low SMBC, SMBD, VREG = 1.8 V 0.8 VOL Output low voltage SMBC, SMBD, VREG = 1.8 V, IOL = 1.5 mA 0.4 CIN Input capacitance ILKG Input leakage current RPD Pulldown resistance V 5 0.7 UNIT 1.0 V V pF 1 µA 1.3 MΩ 7.12 Electrical Characteristics: PRES, BTP_INT, DISP Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER VIH High-level input VIL Low-level input VOH Output voltage high VOL Output voltage low CIN Input capacitance ILKG Input leakage current 10 TEST CONDITIONS MIN TYP MAX 1.3 V 0.55 VBAT > 5.5 V, IOH = –0 µA 3.5 VBAT > 5.5 V, IOH = –10 µA 1.8 V V IOL = 1.5 mA 0.4 5 V pF 1 Submit Documentation Feedback UNIT µA Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 Electrical Characteristics: PRES, BTP_INT, DISP (continued) Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS Output reverse resistance RO MIN Between PRES or BTP_INT or DISP and PBI TYP MAX UNIT 8 kΩ 7.13 Electrical Characteristics: LEDCNTLA, LEDCNTLB, LEDCNTLC Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS VIH High-level input VIL Low-level input MIN TYP MAX UNIT 1.45 V 0.55 VOH Output voltage high VBAT > 3.0 V, IOH = –22.5 mA VOL Output voltage low IOL = 1.5 mA ISC High level output current protection IOL Low level output current VBAT > 3.0 V, VOH = 0.4 V ILEDCNTLx Current matching between LEDCNTLx VBAT = VLEDCNTLx + 2.5 V CIN Input capacitance ILKG Input leakage current fLEDCNTLx Frequency of LED pattern V VBAT – 1.6 V 0.4 V –30 –45 –6 0 mA 15.75 22.5 29.25 mA ±1% 20 pF 1 µA 124 Hz 7.14 Electrical Characteristics: Coulomb Counter Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS Input voltage range Full scale range Integral nonlinearity (1) 16-bit, best fit over input voltage range Offset error Offset error drift Gain error 15-bit + sign, over input voltage range Gain error drift 15-bit + sign, over input voltage range TYP MAX 0.1 –VREF1/10 VREF1/10 UNIT V V ±5.2 ±22.3 16-bit, Post-calibration ±5 ±10 µV 15-bit + sign, Post-calibration 0.2 0.3 µV/°C ±0.2% ±0.8% Effective input resistance (1) MIN –0.1 150 LSB FSR PPM/°C 2.5 N MΩ 15 1 LSB = VREF1/(10 × 2 ) = 1.215/(10 × 2 ) = 3.71 µV 7.15 Electrical Characteristics: CC Digital Filter Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS Conversion time Single conversion Effective resolution Single conversion MIN TYP MAX UNIT 250 15 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 ms Bits 11 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com 7.16 Electrical Characteristics: ADC Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER Input voltage range Full scale range Integral nonlinearity (1) TEST CONDITIONS MIN TYP MAX Internal reference (VREF1) –0.2 1 External reference (VREG) –0.2 0.8 × VREG VFS = VREF1 or VREG –VFS VFS 16-bit, best fit, –0.1 V to 0.8 × VREF1 ±6.6 16-bit, best fit, –0.2 V to –0.1 V ±13.1 Offset error (2) 16-bit, Post-calibration, VFS = VREF1 ±67 ±157 Offset error drift 16-bit, Post-calibration, VFS = VREF1 0.6 3 Gain error 16-bit, –0.1 V to 0.8 × VFS ±0.2% ±0.8% Gain error drift 16-bit, –0.1 V to 0.8 × VFS 150 Effective input resistance (1) (2) N 8 UNIT V V LSB µV µV/°C FSR PPM/°C MΩ 15 1 LSB = VREF1/(2 ) = 1.225/(2 ) = 37.4 µV (when tCONV = 31.25 ms) For VC1–VSS, VC2–VC1, VC3–VC2, VC4–VC3, VC4–VSS, PACK–VSS, and VREF1/2, the offset error is multiplied by (1/ADC multiplexer scaling factor (K)). 7.17 Electrical Characteristics: ADC Digital Filter Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER Conversion time Resolution Effective resolution TEST CONDITIONS MIN TYP Single conversion 31.25 Single conversion 15.63 Single conversion 7.81 Single conversion 1.95 No missing codes 16 With sign, tCONV = 31.25 ms 14 15 With sign, tCONV = 15.63 ms 13 14 With sign, tCONV = 7.81 ms 11 12 With sign, tCONV = 1.95 ms 9 10 MAX UNIT ms Bits Bits 7.18 Electrical Characteristics: CHG, DSG FET Drive Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER Output voltage ratio V(FETON) V(FETOFF) tR 12 MIN TYP MAX RatioDSG = (VDSG – VBAT)/VBAT, 2.2 V < VBAT < 4.92 V, 10 MΩ between PACK and DSG TEST CONDITIONS 2.133 2.333 2.433 RatioCHG = (VCHG – VBAT)/VBAT, 2.2 V < VBAT < 4.92 V, 10 MΩ between BAT and CHG 2.133 2.333 2.433 10.5 11.5 12 10.5 11.5 12 — VDSG(ON) = VDSG – VBAT, VBAT ≥ 4.92 V, 10 MΩ between PACK and DSG, VBAT = 18 V Output voltage, CHG and DSG on VCHG(ON) = VCHG – VBAT, VBAT ≥ 4.92 V, 10 MΩ between BAT and CHG, VBAT = 18 V V VDSG(OFF) = VDSG – VPACK, 10 MΩ between PACK and Output voltage, DSG CHG and DSG off VCHG(OFF) = VCHG – VBAT, 10 MΩ between BAT and CHG Rise time –0.4 0.4 –0.4 0.4 VDSG from 0% to 35% VDSG(ON)(TYP), VBAT ≥ 2.2 V, CL = 4.7 nF between DSG and PACK, 5.1 kΩ between DSG and CL, 10 MΩ between PACK and DSG 200 500 VCHG from 0% to 35% VCHG(ON)(TYP), VBAT ≥ 2.2 V, CL = 4.7 nF between CHG and BAT, 5.1 kΩ between CHG and CL, 10 MΩ between BAT and CHG 200 500 Submit Documentation Feedback UNIT V µs Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 Electrical Characteristics: CHG, DSG FET Drive (continued) Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER tF TEST CONDITIONS Fall time TYP MAX VDSG from VDSG(ON)(TYP) to 1 V, VBAT ≥ 2.2 V, CL = 4.7 nF between DSG and PACK, 5.1 kΩ between DSG and CL, 10 MΩ between PACK and DSG MIN 40 300 VCHG from VCHG(ON)(TYP) to 1 V, VBAT ≥ 2.2 V, CL = 4.7 nF between CHG and BAT, 5.1 kΩ between CHG and CL, 10 MΩ between BAT and CHG 40 200 UNIT µs 7.19 Electrical Characteristics: PCHG FET Drive Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS V(FETON) Output voltage, PCHG on VPCHG(ON) = VVCC – VPCHG, 10 MΩ between VCC and PCHG V(FETOFF) Output voltage, PCHG off VPCHG(OFF) = VVCC – VPCHG, 10 MΩ between VCC and PCHG tR Rise time VPCHG from 10% to 90% VPCHG(ON)(TYP), VVCC ≥ 8 V, CL = 4.7 nF between PCHG and VCC, 5.1 kΩ between PCHG and CL, 10 MΩ between VCC and CHG tF Fall time VPCHG from 90% to 10% VPCHG(ON)(TYP), VCC ≥ 8 V, CL = 4.7 nF between PCHG and VCC, 5.1 kΩ between PCHG and CL, 10 MΩ between VCC and CHG MIN TYP MAX 6 7 8 V 0.4 V 40 200 µs 40 200 µs –0.4 UNIT 7.20 Electrical Characteristics: FUSE Drive Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER VOH Output voltage high VIH High-level input IAFEFUSE(PU) Internal pullup current RAFEFUSE Output impedance CIN Input capacitance tDELAY Fuse trip detection delay tRISE Fuse output rise time MIN TYP MAX VBAT ≥ 8 V, CL = 1 nF, IAFEFUSE = 0 µA TEST CONDITIONS 6 7 8.65 VBAT < 8 V, CL = 1 nF, IAFEFUSE = 0 µA VBAT – 0.1 1.5 VBAT ≥ 8 V, VAFEFUSE = VSS 2 UNIT V VBAT 2.0 2.5 V 150 330 nA 2.6 3.2 kΩ 5 128 VBAT ≥ 8 V, CL = 1 nF, VOH = 0 V to 5 V 5 pF 256 µs 20 µs 7.21 Electrical Characteristics: Internal Temperature Sensor Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER VTEMP TEST CONDITIONS MIN TYP MAX Internal VTEMPP temperature sensor voltage drift VTEMPP – VTEMPN, assured by design –1.9 –2.0 –2.1 0.177 0.178 0.179 UNIT mV/°C Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 13 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com 7.22 Electrical Characteristics: TS1, TS2, TS3, TS4 Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX TS1, TS2, TS3, TS4, VBIAS = VREF1 –0.2 0.8 × VREF1 TS1, TS2, TS3, TS4, VBIAS = VREG –0.2 0.8 × VREG UNIT VIN Input voltage range RNTC(PU) Internal pullup resistance TS1, TS2, TS3, TS4 14.4 18 21.6 kΩ RNTC(DRIFT) Resistance drift over temperature TS1, TS2, TS3, TS4 –360 –280 –200 PPM/°C V 7.23 Electrical Characteristics: PTC, PTCEN Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT 1.2 2.5 3.95 MΩ RPTC(TRIP) PTC trip resistance VPTC(TRIP) PTC trip voltage VPTC(TRIP) = VPTCEN – VPTC 200 500 890 mV IPTC Internal PTC current bias TA = –40°C to 110°C 200 290 350 nA tPTC(DELAY) PTC delay time TA = –40°C to 110°C 40 80 145 ms 7.24 Electrical Characteristics: Internal 1.8-V LDO Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX 1.6 1.8 2.0 VREG Regulator voltage ΔVO(TEMP) Regulator output over temperature ΔVREG/ΔTA, IREG = 10 mA ΔVO(LINE) Line regulation ΔVREG/ΔVBAT, VBAT = 10 mA –0 .6% 0.5% ΔVO(LOAD) Load regulation ΔVREG/ΔIREG, IREG = 0 mA to 10 mA –1.5% 1.5% IREG Regulator output current limit VREG = 0.9 × VREG(NOM), VIN > 2.2 V 20 ISC Regulator shortcircuit current limit VREG = 0 × VREG(NOM) 25 PSRRREG Power supply rejection ratio ΔVBAT/ΔVREG, IREG = 10 mA ,VIN > 2.5 V, f = 10 Hz VSLEW Slew rate enhancement voltage threshold VREG UNIT V ±0.25% 1.58 mA 40 55 mA 40 dB 1.65 V 7.25 Electrical Characteristics: High-Frequency Oscillator Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER fHFO TEST CONDITIONS MIN TYP TA = –20°C to 70°C, includes frequency drift –2.5% ±0.25% 2.5% TA = –40°C to 85°C, includes frequency drift –3.5% ±0.25% 3.5% Operating frequency fHFO(ERR) Frequency error tHFO(SU) Start-up time 16.78 TA = –20°C to 85°C, oscillator frequency within +/–3% of nominal oscillator frequency within +/–3% of nominal 14 MAX Submit Documentation Feedback UNIT MHz 4 ms 100 µs Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 7.26 Electrical Characteristics: Low-Frequency Oscillator Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER fLFO Operating frequency fLFO(ERR) Frequency error fLFO(FAIL) Failure detection frequency TEST CONDITIONS MIN TYP MAX UNIT 262.144 kHz TA = –20°C to 70°C, includes frequency drift –1.5% ±0.25% 1.5% TA = –40°C to 85°C, includes frequency drift –2.5 ±0.25 2.5 30 80 100 kHz 7.27 Electrical Characteristics: Voltage Reference 1 Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER VREF1 Internal reference voltage VREF1(DRIFT) Internal reference voltage drift TEST CONDITIONS TA = 25°C, after trim MIN TYP MAX UNIT 1.21 1.215 1.22 V TA = 0°C to 60°C, after trim ±50 TA = –40°C to 85°C, after trim ±80 PPM/°C 7.28 Electrical Characteristics: Voltage Reference 2 Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER VREF2 Internal reference voltage VREF2(DRIFT) Internal reference voltage drift TEST CONDITIONS TA = 25°C, after trim MIN TYP MAX UNIT 1.22 1.225 1.23 V TA = 0°C to 60°C, after trim ±50 TA = –40°C to 85°C, after trim ±80 PPM/°C 7.29 Electrical Characteristics: Instruction Flash Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS Data retention Flash programming write cycles MIN TYP MAX UNIT 10 Years 1000 Cycles tPROGWORD Word programming time TA = –40°C to 85°C 40 µs tMASSERASE Mass-erase time TA = –40°C to 85°C 40 ms tPAGEERASE Page-erase time TA = –40°C to 85°C 40 ms IFLASHREAD Flash-read current TA = –40°C to 85°C 2 mA IFLASHWRITE Flash-write current TA = –40°C to 85°C 5 mA IFLASHERASE Flash-erase current TA = –40°C to 85°C 15 mA 7.30 Electrical Characteristics: Data Flash Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS Data retention Flash programming write cycles tPROGWORD Word programming time TA = –40°C to 85°C MIN TYP MAX UNIT 10 Years 20000 Cycles 40 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 µs 15 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com Electrical Characteristics: Data Flash (continued) Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT tMASSERASE Mass-erase time TA = –40°C to 85°C 40 ms tPAGEERASE Page-erase time TA = –40°C to 85°C 40 ms IFLASHREAD Flash-read current TA = –40°C to 85°C 1 mA IFLASHWRITE Flash-write current TA = –40°C to 85°C 5 mA IFLASHERASE Flash-erase current TA = –40°C to 85°C 15 mA 7.31 Electrical Characteristics: OCD, SCC, SCD1, SCD2 Current Protection Thresholds Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) PARAMETER OCD detection threshold voltage range VOCD = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 VOCD OCD detection threshold voltage program step ΔVOCD SCC detection threshold voltage program step ΔVSCC SCD1 detection threshold voltage program step ΔVSCD1 SCD2 detection threshold voltage program step ΔVSCD2 VOFFSET OCD, SCC, and SCDx offset error VSCALE OCD, SCC, and SCDx scale error –100 –8.3 –50 mV 44.4 200 22.2 100 mV VSCC = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 22.2 VSCC = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 11.1 mV –44.4 –200 –22.2 –100 mV VSCD1 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 –22.2 VSCD1 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 –11.1 mV –44.4 –200 –22.2 –100 mV VSCD2 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 –22.2 VSCD2 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 –11.1 No trim Post-trim Submit Documentation Feedback UNIT mV –2.78 Post-trim MAX –16.6 VOCD = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 VSCD2 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 SCD2 detection threshold voltage range VSCD2 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 VSCD2 TYP –5.56 VSCD1 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 SCD1 detection threshold voltage range VSCD1 = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 VSCD1 MIN VOCD = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 VSCC = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 SCC detection threshold voltage range VSCC = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 0 VSCC 16 TEST CONDITIONS VOCD = VSRP – VSRN, AFE PROTECTION CONTROL[RSNS] = 1 mV –2.5 2.5 –10% 10% –5% 5% mV — Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 7.32 Timing Requirements: OCD, SCC, SCD1, SCD2 Current Protection Timing Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) MIN NOM MAX tOCD OCD detection delay time ΔtOCD OCD detection delay time program step tSCC SCC detection delay time ΔtSCC SCC detection delay time program step tSCD1 SCD1 detection delay time AFE PROTECTION CONTROL[SCDDx2] = 0 0 915 AFE PROTECTION CONTROL[SCDDx2] = 1 0 1850 SCD1 detection delay time program step AFE PROTECTION CONTROL[SCDDx2] = 0 61 ΔtSCD1 AFE PROTECTION CONTROL[SCDDx2] = 1 121 tSCD2 SCD2 detection delay time AFE PROTECTION CONTROL[SCDDx2] = 0 0 458 AFE PROTECTION CONTROL[SCDDx2] = 1 0 915 SCD2 detection delay time program step AFE PROTECTION CONTROL[SCDDx2] = 0 30.5 ΔtSCD2 AFE PROTECTION CONTROL[SCDDx2] = 1 61 tDETECT Current fault detect time VSRP – VSRN = VT – 3 mV for OCD, SCD1, and SC2, VSRP – VSRN = VT + 3 mV for SCC tACC Current fault delay time accuracy Max delay setting 1 UNIT 31 ms 2 0 ms 915 µs 61 µs µs µs µs µs 160 –10% µs 10% 7.33 Timing Requirements: SMBus Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) MIN NOM MAX UNIT 100 kHz fSMB SMBus operating frequency SLAVE mode, SMBC 50% duty cycle fMAS SMBus master clock frequency MASTER mode, no clock low slave extend tBUF Bus free time between start and stop 4.7 µs tHD(START) Hold time after (repeated) start 4.0 µs tSU(START) Repeated start setup time 4.7 µs tSU(STOP) Stop setup time 4.0 µs tHD(DATA) Data hold time 300 ns tSU(DATA) Data setup time 250 tTIMEOUT Error signal detect time 25 tLOW Clock low period 4.7 tHIGH Clock high period 4.0 tR Clock rise time tF Clock fall time 10 51.2 kHz ns 35 ms µs 50 µs 10% to 90% 1000 ns 90% to 10% 300 ns tLOW(SEXT) Cumulative clock low slave extend time 25 ms tLOW(MEXT) Cumulative clock low master extend time 10 ms Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 17 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com 7.34 Timing Requirements: SMBus XL Typical values stated where TA = 25°C and VCC = 14.4 V, Min/Max values stated where TA = –40°C to 85°C and VCC = 2.2 V to 26 V (unless otherwise noted) MIN SLAVE mode NOM MAX UNIT 400 kHz fSMBXL SMBus XL operating frequency tBUF Bus free time between start and stop 4.7 µs tHD(START) Hold time after (repeated) start 4.0 µs tSU(START) Repeated start setup time 4.7 µs tSU(STOP) Stop setup time 4.0 µs tTIMEOUT Error signal detect time 20 ms tLOW Clock low period 20 µs tHIGH Clock high period 20 µs 5 TtR tSU(STOP)p 40 TtF TtF TtHIGHT tHD(START) TtBUFT SMBC SMBC SMBD SMBD P TtR TtLOWT S tHD(DATA)T Start and Stop Condition TtSU(DATA) Wait and Hold Condition tSU(START)T TtTIMEOUT SMBC SMBC SMBD SMBD S Timeout Condition Repeated Start Condition Figure 4. SMBus Timing Diagram 18 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 7.35 Typical Characteristics 0.15 8.0 Max CC Offset Error Min CC Offset Error 6.0 ADC Offset Error (µV) CC Offset Error ( V) 0.10 0.05 0.00 ±0.05 ±0.10 4.0 2.0 0.0 ±2.0 ±4.0 ±6.0 ±0.15 Max ADC Offset Error Min ADC Offset Error ±8.0 ±40 ±20 0 20 40 60 80 100 Temperature (ƒC) 120 ±40 Figure 5. CC Offset Error vs. Temperature 20 40 60 80 100 120 C003 Figure 6. ADC Offset Error vs. Temperature 264 Low-Frequency Oscillator (kHz) Reference Voltage (V) 0 Temperature (°C) 1.24 1.23 1.22 1.21 1.20 262 260 258 256 254 252 250 ±40 0 ±20 20 40 60 80 Temperature (ƒC) 100 ±40 0 ±20 20 40 60 80 Temperature (ƒC) C006 Figure 7. Reference Voltage vs. Temperature 100 C007 Figure 8. Low-Frequency Oscillator vs. Temperature 16.9 ±24.6 OCD Protection Threshold (mV) High-Frequency Oscillator (MHz) ±20 C001 16.8 16.7 16.6 ±24.8 ±25.0 ±25.2 ±25.4 ±25.6 ±25.8 ±40 ±20 0 20 40 60 Temperature (ƒC) 80 100 120 ±40 ±20 0 20 40 60 80 100 Temperature (ƒC) C008 120 C009 Threshold setting is –25 mV. Figure 9. High-Frequency Oscillator vs. Temperature Figure 10. Overcurrent Discharge Protection Threshold vs. Temperature Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 19 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com Typical Characteristics (continued) ±86.0 SCD 1 Protection Threshold (mV) SCC Protection Threshold (mV) 87.4 87.2 87.0 86.8 86.6 86.4 86.2 ±86.2 ±86.4 ±86.6 ±86.8 ±87.0 ±87.2 ±40 ±20 0 20 40 60 80 100 Temperature (ƒC) 120 ±40 ±20 0 C010 Threshold setting is 88.85 mV. 20 40 60 80 100 Temperature (ƒC) 120 C011 Threshold setting is –88.85 mV. Figure 11. Short Circuit Charge Protection Threshold vs. Temperature Figure 12. Short Circuit Discharge 1 Protection Threshold vs. Temperature ±172.9 Over-Current Delay Time (mS) SCD 2 Protection Threshold (mV) 11.00 ±173.0 ±173.1 ±173.2 ±173.3 ±173.4 ±173.5 10.95 10.90 10.85 10.80 10.75 10.70 ±173.6 ±40 ±20 0 20 40 60 80 100 Temperature (ƒC) 120 ±40 Threshold setting is –177.7 mV. 20 40 60 80 100 120 C013 Threshold setting is 11 ms. Figure 14. Overcurrent Delay Time vs. Temperature 480 452 450 SC Discharge 1 Delay Time ( S) SC Charge Current Delay Time ( S) 0 Temperature (ƒC) Figure 13. Short Circuit Discharge 2 Protection Threshold vs. Temperature 448 446 444 442 440 438 436 434 432 460 440 420 400 ±40 ±20 0 20 40 60 Temperature (ƒC) 80 100 120 ±40 ±20 0 20 40 60 80 Temperature (ƒC) C014 Threshold setting is 465 µs. 100 120 C015 Threshold setting is 465 µs (including internal delay). Figure 15. Short Circuit Charge Current Delay Time vs. Temperature 20 ±20 C012 Figure 16. Short Circuit Discharge 1 Delay Time vs. Temperature Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 Typical Characteristics (continued) 3.49825 2.4984 2.49835 3.4982 Cell Voltage (V) Cell Voltage (V) 2.4983 2.49825 2.4982 2.49815 2.4981 3.49815 3.4981 3.49805 2.49805 3.498 2.498 ±40 ±20 0 20 40 60 80 100 Temperature (ƒC) 120 ±40 ±20 0 20 40 60 80 100 Temperature (ƒC) C016 120 C017 This is the VCELL average for single cell. Figure 17. VCELL Measurement at 2.5-V vs. Temperature Figure 18. VCELL Measurement at 3.5-V vs. Temperature 4.24805 Measurement Current (mA) 99.25 Cell Voltage (V) 4.248 4.24795 4.2479 4.24785 4.2478 99.20 99.15 99.10 99.05 99.00 ±40 ±20 0 20 40 60 Temperature (ƒC) 80 100 120 ±40 0 20 40 60 80 100 Temperature (ƒC) C018 This is the VCELL average for single cell. ±20 120 C019 ISET = 100 mA Figure 19. VCELL Measurement at 4.25-V vs. Temperature Figure 20. I measured vs. Temperature Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 21 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com 8 Detailed Description 8.1 Overview The BQ40Z50 device, incorporating patented Impedance Track™ technology, provides cell balancing while charging or at rest. This fully integrated, single-chip, pack-based solution provides a rich array of features for gas gauging, protection, and authentication for 1-series, 2-series, 3-series, and 4-series cell Li-Ion and Li-Polymer battery packs, including a diagnostic lifetime data monitor and black box recorder. Cell Detach Detection Wake Comparator PCHG DSG CHG PBI VCC BAT VSS Cell, Stack, Pack Voltage PACK VC2 VC1 VC4 Cell Balancing VC3 8.2 Functional Block Diagram Power Mode Control High Side N-CH FET Drive P-CH FET Drive Power On Reset Zero Volt Charge Control PTC Overtemp Short Circuit Comparator PTCEN PTC FUSE Control FUSE High Voltage I/O PRES or SHUTDN SRP SRN Over Current Comparator Voltage Reference2 NTC Bias Random Number Generator Watchdog Timer Internal Temp Sensor LED Display Drive I/O TS1 TS2 TS3 ADC/CC FRONTEND ADC MUX DISP LEDCNTLC LEDCNTLB LEDCNTLA TS4 Voltage Reference1 BTP_INT AFE Control Low Frequency Oscillator 1.8V LDO Regulator AFE COM Engine SBS High Voltage Translation I/O & Interrupt Controller AFE COM Engine SBS COM Engine SMBD SMBC High Frequency Oscillator Low Voltage I/O I/O ADC/CC Digital Filter Data (8bit) bqBMP CPU PMInstr (8bit) Timers & PWM DMAddr (16bit) PMAddr (16bit) Program Flash EEPROM Data Flash EEPROM Data SRAM Copyright © 2017, Texas Instruments Incorporated 22 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 8.3 Feature Description 8.3.1 Primary (1st Level) Safety Features The BQ40Z50 supports a wide range of battery and system protection features that can easily be configured. See the BQ40Z50 Technical Reference Manual (SLUUA43) for detailed descriptions of each protection function. The primary safety features include: • • • • • • • • • • • • • • • • • • • • Cell Overvoltage Protection Cell Undervoltage Protection Cell Undervoltage Protection Compensated Overcurrent in Charge Protection Overcurrent in Discharge Protection Overload in Discharge Protection Short Circuit in Charge Protection Short Circuit in Discharge Protection Overtemperature in Charge Protection Overtemperature in Discharge Protection Undertemperature in Charge Protection Undertemperature in Discharge Protection Overtemperature FET protection Precharge Timeout Protection Host Watchdog Timeout Protection Fast Charge Timeout Protection Overcharge Protection Overcharging Voltage Protection Overcharging Current Protection Over Precharge Current Protection 8.3.2 Secondary (2nd Level) Safety Features The secondary safety features of the BQ40Z50 can be used to indicate more serious faults via the FUSE pin. This pin can be used to blow an in-line fuse to permanently disable the battery pack from charging or discharging. See the BQ40Z50 Technical Reference Manual (SLUUA43) for detailed descriptions of each protection function. The secondary safety features provide protection against: • Safety Overvoltage Permanent Failure • Safety Undervoltage Permanent Failure • Safety Overtemperature Permanent Failure • Safety FET Overtemperature Permanent Failure • Qmax Imbalance Permanent Failure • Impedance Imbalance Permanent Failure • Capacity Degradation Permanent Failure • Cell Balancing Permanent Failure • Fuse Failure Permanent Failure • PTC Permanent Failure • Voltage Imbalance at Rest Permanent Failure • Voltage Imbalance Active Permanent Failure • Charge FET Permanent Failure • Discharge FET Permanent Failure • AFE Register Permanent Failure • AFE Communication Permanent Failure • Second Level Protector Permanent Failure Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 23 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com Feature Description (continued) • • • • Instruction Flash Checksum Permanent Failure Open Cell Connection Permanent Failure Data Flash Permanent Failure Open Thermistor Permanent Failure 8.3.3 Charge Control Features The BQ40Z50 charge control features include: • • • • • • • Supports JEITA temperature ranges. Reports charging voltage and charging current according to the active temperature range Handles more complex charging profiles. Allows for splitting the standard temperature range into two subranges and allows for varying the charging current according to the cell voltage Reports the appropriate charging current needed for constant current charging and the appropriate charging voltage needed for constant voltage charging to a smart charger using SMBus broadcasts Reduces the charge difference of the battery cells in fully charged state of the battery pack gradually using a voltage-based cell balancing algorithm during charging. A voltage threshold can be set up for cell balancing to be active. This prevents fully charged cells from overcharging and causing excessive degradation and also increases the usable pack energy by preventing premature charge termination. Supports pre-charging/zero-volt charging Supports charge inhibit and charge suspend if battery pack temperature is out of temperature range Reports charging fault and also indicates charge status via charge and discharge alarms 8.3.4 Gas Gauging The BQ40Z50 uses the Impedance Track algorithm to measure and calculate the available capacity in battery cells. The BQ40Z50 accumulates a measure of charge and discharge currents and compensates the charge current measurement for the temperature and state-of-charge of the battery. The BQ40Z50 estimates selfdischarge of the battery and also adjusts the self-discharge estimation based on temperature. The device also has TURBO BOOST mode support, which enables the BQ40Z50 to provide the necessary data for the MCU to determine what level of peak power consumption can be applied without causing a system reset or transient battery voltage level spike to trigger termination flags. See the BQ40Z50 Technical Reference Manual (SLUUA43) for further details. 8.3.5 Configuration 8.3.5.1 Oscillator Function The BQ40Z50 fully integrates the system oscillators and does not require any external components to support this feature. 8.3.5.2 System Present Operation The BQ40Z50 checks the PRES pin periodically (1 s). If PRES input is pulled to ground by the external system, the BQ40Z50 detects this as system present. 8.3.5.3 Emergency Shutdown For battery maintenance, the emergency shutdown feature enables a push button action connecting the SHUTDN pin to shutdown an embedded battery pack system before removing the battery. A high-to-low transition of the SHUTDN pin signals the BQ40Z50 to turn off both CHG and DSG FETs, disconnecting the power from the system to safely remove the battery pack. The CHG and DSG FETs can be turned on again by another high-to-low transition detected by the SHUTDN pin or when a data flash configurable timeout is reached. 8.3.5.4 1-Series, 2-Series, 3-Series, or 4-Series Cell Configuration In a 1-series cell configuration, VC4 is shorted to VC, VC2 and VC1. In a 2-series cell configuration, VC4 is shorted to VC3 and VC2. In a 3-series cell configuration, VC4 is shorted to VC3. 24 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 Feature Description (continued) 8.3.5.5 Cell Balancing The device supports cell balancing by bypassing the current of each cell during charging or at rest. If the device's internal bypass is used, up to 10 mA can be bypassed and multiple cells can be bypassed at the same time. Higher cell balance current can be achieved by using an external cell balancing circuit. In external cell balancing mode, only one cell at a time can be balanced. The cell balancing algorithm determines the amount of charge needed to be bypassed to balance the capacity of all cells. 8.3.6 Battery Parameter Measurements 8.3.6.1 Charge and Discharge Counting The BQ40Z50 uses an integrating delta-sigma analog-to-digital converter (ADC) for current measurement, and a second delta-sigma ADC for individual cell and battery voltage and temperature measurement. The integrating delta-sigma ADC measures the charge/discharge flow of the battery by measuring the voltage drop across a small-value sense resistor between the SRP and SRN terminals. The integrating ADC measures bipolar signals from –0.1 V to 0.1 V. The BQ40Z50 detects charge activity when VSR = V(SRP) – V(SRN) is positive, and discharge activity when VSR = V(SRP) – V(SRN) is negative. The BQ40Z50 continuously integrates the signal over time, using an internal counter. The fundamental rate of the counter is 0.26 nVh. 8.3.7 Battery Trip Point (BTP) Required for WIN8 OS, the battery trip point (BTP) feature indicates when the RSOC of a battery pack has depleted to a certain value set in a DF register. This feature allows a host to program two capacity-based thresholds that govern the triggering of a BTP interrupt on the BTP_INT pin and the setting or clearing of the OperationStatus[BTP_INT] on the basis of RemainingCapacity(). An internal weak pull-up is applied when the BTP feature is active. Depending on the system design, an external pull-up may be required to put on the BTP_INT pin. See Electrical Characteristics: PRES, BTP_INT, DISP for details. 8.3.8 Lifetime Data Logging Features The BQ40Z50 offers lifetime data logging for several critical battery parameters. The following parameters are updated every 10 hours if a difference is detected between values in RAM and data flash: • Maximum and Minimum Cell Voltages • Maximum Delta Cell Voltage • Maximum Charge Current • Maximum Discharge Current • Maximum Average Discharge Current • Maximum Average Discharge Power • Maximum and Minimum Cell Temperature • Maximum Delta Cell Temperature • Maximum and Minimum Internal Sensor Temperature • Maximum FET Temperature • Number of Safety Events Occurrences and the Last Cycle of the Occurrence • Number of Valid Charge Termination and the Last Cycle of the Valid Charge Termination • Number of Qmax and Ra Updates and the Last Cycle of the Qmax and Ra Updates • Number of Shutdown Events • Cell Balancing Time for Each Cell (This data is updated every 2 hours if a difference is detected.) • Total FW Runtime and Time Spent in Each Temperature Range (This data is updated every 2 hours if a difference is detected.) Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 25 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com Feature Description (continued) 8.3.9 Authentication The BQ40Z50 supports authentication by the host using SHA-1. 8.3.10 LED Display The BQ40Z50 can drive a 3-, 4-, or 5- segment LED display for remaining capacity indication and/or a permanent fail (PF) error code indication. 8.3.11 Voltage The BQ40Z50 updates the individual series cell voltages at 0.25-second intervals. The internal ADC of the BQ40Z50 measures the voltage, and scales and calibrates it appropriately. This data is also used to calculate the impedance of the cell for the Impedance Track gas gauging. 8.3.12 Current The BQ40Z50 uses the SRP and SRN inputs to measure and calculate the battery charge and discharge current using a 1-mΩ to 3-mΩ typ. sense resistor. 8.3.13 Temperature The BQ40Z50 has an internal temperature sensor and inputs for four external temperature sensors. All five temperature sensor options can be individually enabled and configured for cell or FET temperature usage. Two configurable thermistor models are provided to allow the monitoring of cell temperature in addition to FET temperature, which use a different thermistor profile. 8.3.14 Communications The BQ40Z50 uses SMBus v1.1 with MASTER mode and packet error checking (PEC) options per the SBS specification. 8.3.14.1 SMBus On and Off State The BQ40Z50 detects an SMBus off state when SMBC and SMBD are low for two or more seconds. Clearing this state requires that either SMBC or SMBD transition high. The communication bus will resume activity within 1 ms. 8.3.14.2 SBS Commands See the BQ40Z50 Technical Reference Manual (SLUUA43) for further details. 8.4 Device Functional Modes The BQ40Z50 supports three power modes to reduce power consumption: • In NORMAL mode, the BQ40Z50 performs measurements, calculations, protection decisions, and data updates in 250-ms intervals. Between these intervals, the BQ40Z50 is in a reduced power stage. • In SLEEP mode, the BQ40Z50 performs measurements, calculations, protection decisions, and data updates in adjustable time intervals. Between these intervals, the BQ40Z50 is in a reduced power stage. The BQ40Z50 has a wake function that enables exit from SLEEP mode when current flow or failure is detected. • In SHUTDOWN mode, the BQ40Z50 is completely disabled. 26 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 9 Applications and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 9.1 Application Information The BQ40Z50 is a gas gauge with primary protection support, and that can be used with a 1-series to 4-series Li-Ion/Li Polymer battery pack. To implement and design a comprehensive set of parameters for a specific battery pack, users need the Battery Management Studio (bqSTUDIO) graphical user-interface tool installed on a PC during development. The firmware installed on the bqSTUDIO tool has default values for this product, which are summarized in the BQ40Z50 Technical Reference Manual (SLUUA43). Using the bqSTUDIO tool, these default values can be changed to cater to specific application requirements during development once the system parameters, such as fault trigger thresholds for protection, enable/disable of certain features for operation, configuration of cells, chemistry that best matches the cell used, and more are known. This data is referred to as the "golden image." Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 27 BQ40Z50 4P J1 1 2 3 1 2 1 R11 0.1uF C4 1 2 3 4 CD 7 VSS 6 V1 5 U2 BQ2947xyDSG VDD OUT 8 V4 V3 V2 1 FUSE F1 3 2 4P 10M R2 300 R1 FUSEPIN R6 0.1uF C3 R16 51K Q5 Si1406DH SFDxxxx AGND R17 5.1K 3 Q2 Si7116DN R7 5.1K CHG 2.2uF 1 PBI C1 0.1uF C2 R8 100 R9 2 0.1uF Q1 FDN358P R5 10M 5.1K 3 DSG GND Q3 Si7116DN R10 5.1K R3 10M R12 24 10K PTCEN 21 22 23 20 19 17 18 Q4 2N7002K 1 10K R4 C12 RT1 D8 LED2 D6 LED4 BAT CHGND D5 LED3 D7 LED1 0.1uF 2 10K D9 LED5 4P BAT 10K R32 S1 Wake PACK+ A A' 5 4 3 2 1 B B' For Thumbus-SMB SMBD I2C_VOUT SMBC CHGND 6 7 100 R13 1K R14 C5 C7 0.1uF 0.1uF C6 5.1K C13 PTC LEDCNTLB LEDCNTLC LEDCNTLA SMBC DISP SMBD CHGND 1K R29 100 R25 D4 R24 D3 100 R27 D2 200 R26 200 2001 2 A B A' B' J7 S2 LED DISPLAY GND R28 B B' SHUTDOWN A A' S3 J6 SMBC SMBD 4 3 2 PACK+ J2 1 CHGND C8 0.1uF C10 0.1uF SMBD VSS SMBC 2 1 3 2 1 J4 J3 PACK+ PACK+ Sys Pres PACK- PACK- PACK+ CHGND Product Folder Links: BQ40Z50 1K 0.1uF BAT D1 BAT54HT1 VC 4 VC 3 VC 2 VC 1 SRN NC SRP TP12 10K RT5 GND RT4 10K GND CHGND GND SIDE BAT 3 2 3 4 5 6 7 8 10K RT3 GND MM3ZxxVyC Copyright © 2017, Texas Instruments Incorporated SMBD R15 GND C15 C16 0.1uF C17 RT2 10K GND GND GND SIDE 1 GND SIDE 2 3 3 2 1 FUSE 25 C9 0.1uF C14 0.1uF 0.1uF 0.1uF GND 28 GND C21 DNP GND 1 2 1 2 C11 0.1uF R23 SRN DNP C20 DSG 1K 100 R22 C18 0.1uF R31 100 30 NC 29 CHG R18 100 R21 TP3 SRP R30 0.001 R19 CHGND 1 1 1K R20 100 100 GND C19 DNP 100 GND 1 1 3P 2P 1P J5 1N NT1 Net-Tie IC ground should be connected to the 1N cell tab. Place RT1 close to Q2 and Q3. Replace D1 and R9 with a 10 ohm resistor for single cell applications PCHG 1 SMBC SMBC SMBD 1 2 1 2 GND SIDE 4P AGND GND 1 3 MM3ZxxVyC 5 10 TS1 11 TS2 1 2 3 1 5 1 1 1 1 32 4 26 1 16 PRES or SHUTDN 27 VCC 14 NC 15 BTP_INT 31 33 BAT 1 1 PWPD 12 TS3 13 TS4 PACK 1 Copyright © 2013–2019, Texas Instruments Incorporated Submit Documentation Feedback 28 2 MM3ZxxVyC 1 VSS 9 4 1 1 1 1 1 3 6 4 1 1 1 EP 9 5 2 1 1 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 9.2 Typical Applications Figure 21. Application Schematic BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 Typical Applications (continued) 9.2.1 Design Requirements Table 1 shows the default settings for the main parameters. Use the bqSTUDIO tool to update the settings to meet the specific application or battery pack configuration requirements. The device should be calibrated before any gauging test. Follow the bqSTUDIO Calibration page to calibrate the device, and use the bqSTUDIO Chemistry page to update the match chemistry profile to the device. Table 1. Design Parameters (1) DESIGN PARAMETER EXAMPLE Cell Configuration 3s1p (3-series with 1 Parallel) (1) Design Capacity 4400 mAh Device Chemistry 1210 (LiCoO2/graphitized carbon) Cell Overvoltage at Standard Temperature 4300 mV Cell Undervoltage 2500 mV Shutdown Voltage 2300 mV Overcurrent in CHARGE Mode 6000 mA Overcurrent in DISCHARGE Mode –6000 mA Short Circuit in CHARGE Mode 0.1 V/Rsense across SRP, SRN Short Circuit in DISCHARGE Mode 0.1 V/Rsense across SRP, SRN Safety Overvoltage 4500 mV Cell Balancing Disabled Internal and External Temperature Sensor External Temperature Sensor is used. Undertemperature Charging 0°C Undertemperature Discharging 0°C BROADCAST Mode Disabled Battery Trip Point (BTP) with active high interrupt Disabled When using the device the first time, if the a 1-s or 2-s battery pack is used, then a charger or power supply should be connected to the PACK+ terminal to prevent device shutdown. Then update the cell configuration (see the BQ40Z50 Technical Reference Manual [SLUUA43] for details) before removing the charger connection. 9.2.2 Detailed Design Procedure 9.2.2.1 High-Current Path The high-current path begins at the PACK+ terminal of the battery pack. As charge current travels through the pack, it finds its way through protection FETs, a chemical fuse, the lithium-ion cells and cell connections, and the sense resistor, and then returns to the PACK– terminal (see Figure 22). In addition, some components are placed across the PACK+ and PACK– terminals to reduce effects from electrostatic discharge. 9.2.2.1.1 Protection FETs Select the N-channel charge and discharge FETs for a given application. Most portable battery applications are a good match for the CSD17308Q3. The TI CSD17308Q3 is a 47A, 30-V device with Rds(on) of 8.2 mΩ when the gate drive voltage is 8 V. If a precharge FET is used, R1 is calculated to limit the precharge current to the desired rate. Be sure to account for the power dissipation of the series resistor. The precharge current is limited to (VCHARGER – VBAT)/R1 and maximum power dissipation is (Vcharger – Vbat)2/R1. The gates of all protection FETs are pulled to the source with a high-value resistor between the gate and source to ensure they are turned off if the gate drive is open. Capacitors C1 and C2 help protect the FETs during an ESD event. Using two devices ensures normal operation if one becomes shorted. To have good ESD protection, the copper trace inductance of the capacitor leads must be designed to be as short and wide as possible. Ensure that the voltage rating of both C1 and C2 are adequate to hold off the applied voltage if one of the capacitors becomes shorted. Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 29 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 C1 R1 www.ti.com 0.1 F C2 0.1 F 300 Q1 FDN358P Q3 Si7114DN Q2 Si7114DN R2 10M R5 R3 10M Q4 2N7002K 10M R4 10K R7 5.1K R8 5.1K R9 100 R10 5.1K Copyright © 2016, Texas Instruments Incorporated Figure 22. BQ40Z50 Protection FETs 9.2.2.1.2 Chemical Fuse The chemical fuse (Dexerials, Uchihashi, and so forth) is ignited under command from either the bq294700 secondary voltage protection IC or from the FUSE pin of the gas gauge. Either of these events applies a positive voltage to the gate of Q5, shown in Figure 23, which then sinks current from the third terminal of the fuse, causing it to ignite and open permanently. It is important to carefully review the fuse specifications and match the required ignition current to that available from the N-channel FET. Ensure that the proper voltage, current, and Rds(on) ratings are used for this device. The fuse control circuit is discussed in detail in FUSE Circuitry. 30 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 4P F1 DNP 1 2 6 5 2 1 3 Q5 Si1406DH 4 3 R6 51K to 2nd Level Protector R16 C3 0.1 F 5.1K R17 5.1K to FUSE Pin Copyright © 2016, Texas Instruments Incorporated Figure 23. FUSE Circuit 9.2.2.1.3 Lithium-Ion Cell Connections The important part to remember about the cell connections is that high current flows through the top and bottom connections; therefore, the voltage sense leads at these points must be made with a Kelvin connection to avoid any errors due to a drop in the high-current copper trace. The location marked 4P in Figure 24 indicates the Kelvin connection of the most positive battery node. The connection marked 1N is equally important. The VC5 pin (a ground reference for cell voltage measurement), which is in the older generation devices, is not in the BQ40Z50 device. Therefore, the single-point connection at 1N to the low-current ground is needed to avoid an undesired voltage drop through long traces while the gas gauge is measuring the bottom cell voltage. Figure 24. Lithium-Ion Cell Connections Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 31 BQ40Z50 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 www.ti.com 9.2.2.1.4 Sense Resistor As with the cell connections, the quality of the Kelvin connections at the sense resistor is critical. The sense resistor must have a temperature coefficient no greater than 50 ppm in order to minimize current measurement drift with temperature. Choose the value of the sense resistor to correspond to the available overcurrent and short-circuit ranges of the BQ40Z50. Select the smallest value possible to minimize the negative voltage generated on the BQ40Z50 VSS node(s) during a short circuit. This pin has an absolute minimum of –0.3 V. Parallel resistors can be used as long as good Kelvin sensing is ensured. The device is designed to support a 1mΩ to 3-mΩ sense resistor. The ground scheme of BQ40Z50 is different from the older generation devices. In previous devices, the device ground (or low current ground) is connected to the SRN side of the Rsense resistor pad. The BQ40Z50, however, connects the low-current ground on the SRP side of the Rsense resistor pad, close to the battery 1N terminal (see Lithium-Ion Cell Connections). This is because the BQ40Z50 has one less VC pin (a ground reference pin VC5) compared to the previous devices. The pin was removed and was internally combined to SRP. R19 0.001 50 ppm Copyright © 2016 , Texas Instruments Incorporated Figure 25. Sense Resistor 9.2.2.1.5 ESD Mitigation A pair of series 0.1-μF ceramic capacitors is placed across the PACK+ and PACK– terminals to help in the mitigation of external electrostatic discharges. The two devices in series ensure continued operation of the pack if one of the capacitors becomes shorted. Optionally, a tranzorb such as the SMBJ2A can be placed across the terminals to further improve ESD immunity. 9.2.2.2 Gas Gauge Circuit The Gas Gauge Circuit includes the BQ40Z50 and its peripheral components. These components are divided into the following groups: Differential Low-Pass Filter, PBI, System Present, SMBus Communication, FUSE circuit, and LED. 9.2.2.2.1 Coulomb-Counting Interface The BQ40Z50 uses an integrating delta-sigma ADC for current measurements. Add a 100-Ω resistor from the sense resistor to the SRP and SRN inputs of the device. Place a 0.1-µF (C18) filter capacitor across the SRP and SRN inputs. Optional 0.1-µF filter capacitors (C19 and C20) can be added for additional noise filtering, if required for your circuit. 32 Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 BQ40Z50 www.ti.com SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 C18 0.1 µF C19 DNP C20 DNP R31 100 R30 100 R19 0.001 50 ppm Copyright © 2016, Texas Instruments Incorporated Figure 26. Differential Filter 9.2.2.2.2 Power Supply Decoupling and PBI The BQ40Z50 has an internal LDO that is internally compensated and does not require an external decoupling capacitor. 25 FUSE 27 VCC 26 PACK DSG 28 29 NC PCHG 30 BAT PWPD CHG 31 32 33 The PBI pin is used as a power supply backup input pin providing power during brief transient power outages. A standard 2.2-µF ceramic capacitor is connected from the PBI pin to ground as shown in Figure 27. 1 PBI C13 2.2 μF PTCEN 24 23 2 VC4 PTC 3 VC3 LEDCNTL3 22 4 VC2 LEDCNTL2 21 5 VC1 LEDCNTL1 20 6 SRN SMBC 7 SMBD NC 19 18 DISP 17 PRES 16 1 5 NC NC 14 TS4 13 TS2 TS3 12 11 TS1 10 9 vss 8 SRP Copyright © 2016 , Texas Instruments Incorporated Figure 27. Power Supply Decoupling 9.2.2.2.3 System Present The System Present signal is used to inform the gas gauge whether the pack is installed into or removed from the system. In the host system, this pin is grounded. The PRES pin of the BQ40Z50 is occasionally sampled to test for system present. To save power, an internal pullup is provided by the gas gauge during a brief 4-μs sampling pulse once per second. A resistor can be used to pull the signal low and the resistance must be 20 kΩ or lower to insure that the test pulse is lower than the VIL limit. The pull-up current source is typically 10 µA to 20 µA. Submit Documentation Feedback Copyright © 2013–2019, Texas Instruments Incorporated Product Folder Links: BQ40Z50 33 BQ40Z50 16 PRES BTP_IN www.ti.com 15 14 13 NC TS4 SLUSBS8B – DECEMBER 2013 – REVISED NOVEMBER 2019 VIL
BQ40Z50RSMT 价格&库存

很抱歉,暂时无法提供与“BQ40Z50RSMT”相匹配的价格&库存,您可以联系我们找货

免费人工找货