0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
THS1007IDA

THS1007IDA

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    TSSOP32

  • 描述:

    IC ADC 10BIT PIPELINED 32TSSOP

  • 数据手册
  • 价格&库存
THS1007IDA 数据手册
THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 10-BIT, 4 ANALOG INPUT, 6-MSPS, SIMULTANEOUS SAMPLING ANALOG-TO-DIGITAL CONVERTER FEATURES D Simultaneous Sampling of 4 Single-Ended D D D D D D D D D D D Signals or 2 Differential Signals or Combination of Both Signal-to-Noise and Distortion Ratio: 59 dB at fI = 2 MHz Differential Nonlinearity Error: ±1 LSB Integral Nonlinearity Error: ±1 LSB Auto-Scan Mode for 2, 3, or 4 Inputs 3-V or 5-V Digital Interface Compatible Low Power: 216 mW Max at 5 V Power Down: 1 mW Max 5-V Analog Single Supply Operation Internal Voltage References . . . 50 PPM/°C and ±5% Accuracy Glueless DSP Interface Parallel μC/DSP Interface APPLICATIONS D Radar Applications D Communications D Control Applications D High-Speed DSP Front-End D Automotive Applications DESCRIPTION The THS1007 is a CMOS, low-power, 10-bit, 6 MSPS analog-to-digital converter (ADC). The speed, resolution, bandwidth, and single-supply operation are suited for applications in radar, imaging, high-speed acquisition, and communications. A multistage pipelined architecture with output error correction logic provides for no missing codes over the full operating temperature range. Internal control registers are used to program the ADC into the desired mode. The THS1007 consists of four analog inputs, which are sampled simultaneously. These inputs can be selected individually and configured to single-ended or differential inputs. Internal reference voltages for the ADC (1.5 V and 3.5 V) are provided. An external reference can also be chosen to suit the dc accuracy and temperature drift requirements of the application. The THS1007C is characterized for operation from 0°C to 70°C, and the THS1007I is characterized for operation from −40°C to 85°C. DA (TSSOP) PACKAGE (TOP VIEW) D0 D1 D2 D3 D4 D5 BVDD BGND D6 D7 D8 D9 RA0 RA1 CONV_CLK SYNC 1 32 2 31 3 30 4 29 5 28 6 27 7 26 8 25 9 24 10 23 11 22 12 21 13 20 14 19 15 18 16 17 AINP AINM BINP BINM REFIN REFOUT REFP REFM AGND AVDD CS0 CS1 WR (R/W) RD DVDD DGND ORDERING INFORMATION PACKAGED DEVICE TA TSSOP (DA) 0°C to 70°C THS1007CDA −40°C to 85°C THS1007IDA Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Copyright © 2002, Texas Instruments Incorporated THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. ABSOLUTE MAXIMUM RATINGS over operating free-air temperature range unless otherwise noted(1) UNITS Supply voltage range DGND to DVDD −0.3 V to 6.5 V BGND to BVDD −0.3 V to 6.5 V AGND to AVDD −0.3 V to 6.5 V Analog input voltage range AGND −0.3 V to AVDD + 1.5 V Reference input voltage −0.3 V + AGND to AVDD + 0.3 V Digital input voltage range −0.3 V to BVDD/DVDD + 0.3 V Operating virtual junction temperature range, TJ Operating free-air free air temperature range range, TA −40°C to 150°C THS1007C 0°C to 70°C THS1007I −40°C to 85°C Storage temperature range, Tstg −65°C to 150°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds (1) 260°C Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. RECOMMENDED OPERATING CONDITIONS POWER SUPPLY Supply pp y voltage g MIN NOM MAX AVDD 4.75 5 5.25 DVDD 4.75 5 5.25 BVDD 3 ANALOG AND REFERENCE INPUTS MIN Analog input voltage in single-ended configuration NOM 1 External reference voltage,VREFP (optional) External reference voltage, VREFM (optional) 1.4 Input voltage difference, REFP − REFM DIGITAL INPUTS High level input voltage, High-level voltage VIH Low level input voltage, Low-level voltage VIL MIN BVDD = 3.3 V BVDD = 5.25 V V 5.25 MAX VREFM Common-mode input voltage VCM in differential configuration UNIT UNIT VREFP V 2.5 4 V 3.5 AVDD−1.2 V 1.5 V 2 V NOM MAX UNIT 2 V 2.6 V BVDD = 3.3 V 0.6 BVDD = 5.25 V 0.6 V Input CONV_CLK frequency DVDD = 4.75 V to 5.25 V 0.1 CONV_CLK pulse duration, clock high, tw(CONV_CLKH) DVDD = 4.75 V to 5.25 V 80 83 5000 ns CONV_CLK pulse duration, clock low, tw(CONV_CLKL) DVDD = 4.75 V to 5.25 V 80 83 5000 ns Operating free-air free air temperature, temperature TA 2 THS1007CDA THS1007IDA 6 V 0 70 −40 85 MHz °C THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 ELECTRICAL CHARACTERISTICS over recommended operating conditions, AVDD = DVDD = 5 V, BVDD = 3.3 V, VREF = internal (unless otherwise noted) DIGITAL SPECIFICATIONS PARAMETER TEST CONDITIONS MIN TYP MAX UNIT Digital inputs IIH High-level input current DVDD = digital inputs −50 50 μA IIL Low-level input current Digital input = 0 V −50 50 μA Ci Input capacitance 5 pF Digital outputs VOH High-level output voltage IOH = −50 μA, BVDD = 3.3 V, 5 V VOL Low-level output voltage IOL = 50 μA, BVDD = 3.3 V, 5 V IOZ High-impedance-state output current CS1 = DGND, CS0 = DVDD CO Output capacitance CL Load capacitance at databus D0 − D9 BVDD−0.5 V −10 0.4 V 10 μA 5 pF 30 pF ELECTRICAL CHARACTERISTICS over recommended operating conditions, AVDD = DVDD = 5 V, BVDD = 3.3 V, fs = 6 MSPS, VREF = internal (unless otherwise noted) DC SPECIFICATIONS PARAMETER TEST CONDITIONS Resolution MIN TYP MAX 10 UNIT Bits Accuracy Integral nonlinearity, INL ±1 LSB Differential nonlinearity, DNL ±1 LSB Offset error After calibration in single-ended mode Offset error After calibration in differential mode Gain error LSB ±5 −10 10 LSB −10 10 LSB Analog input Input capacitance Input leakage current 15 VAIN = VREFM to VREFP pF ±10 μA V Internal voltage reference Accuracy, VREFP 3.3 3.5 3.7 Accuracy, VREFM 1.4 1.5 1.6 Temperature coefficient 50 Reference noise 100 Accuracy, REFOUT 2.475 V PPM/° C μV 2.5 2.525 V Power supply IDDA Analog supply current AVDD = DVDD = 5 V, BVDD =3.3 V 36 40 mA IDDD Digital supply current AVDD = DVDD = 5 V, BVDD = 3.3 V 0.5 3 mA IDDB Buffer supply current AVDD = DVDD = 5 V, BVDD = 3.3 V 1.5 4 mA Power dissipation AVDD = DVDD = 5 V, BVDD = 3.3 V 186 216 mW Power dissipation in power down with conversion clock inactive AVDD = DVDD = 5 V, BVDD = 3.3 V 0.25 mW 3 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 ELECTRICAL CHARACTERISTICS over recommended operating conditions, VREF = internal, fs = 6 MSPS, fI = 2 MHz at −1 dBFS (unless otherwise noted) AC SPECIFICATIONS, AVDD = DVDD = 5 V, BVDD = 3.3 V, CL < 30 pF PARAMETER SINAD SNR THD ENOB (SNR) SFDR Signal to noise ratio + distortion Signal-to-noise Signal to noise ratio Signal-to-noise Total harmonic distortion MIN TYP Differential mode TEST CONDITIONS 56 59 dB Single-ended mode 55 58 dB Differential mode 59 61 dB Single-ended mode 58 60 −64 −61 Single-ended mode −63 −60 Single-ended mode Spurious free dynamic range UNIT dB Differential mode Differential mode Effective number of bits MAX dB dB 9 9.5 Bits 8.85 9.35 Bits Differential mode 61 65 dB Single-ended mode 60 64 dB Analog Input Full-power bandwidth with a source impedance of 150 Ω in differential configuration. Full scale sinewave, −3 dB 96 MHz Full-power bandwidth with a source impedance of 150 Ω in single-ended configuration. Full scale sinewave, −3 dB 54 MHz Small-signal bandwidth with a source impedance of 150 Ω in differential configuration. 100 mVpp sinewave, −3 dB 96 MHz Small-signal bandwidth with a source impedance of 150 Ω in single-ended configuration. 100 mVpp sinewave, −3 dB 54 MHz TIMING REQUIREMENTS AVDD = DVDD = 5 V, BVDD = 3.3 V, VREF = internal, CL < 30 pF PARAMETER TEST CONDITIONS MIN TYP MAX UNIT CONV CLK tpipe Latency tsu(CONV_CLKL-READL) Setup time, CONV_CLK low before CS valid 10 tsu(READH-CONV_CLKL) Setup time, CS invalid to CONV_CLK low 20 td(CONV_CLKL-SYNCL) Delay time, CONV_CLK low to SYNC low 10 ns td(CONV_CLKL-SYNCH) Delay time, CONV_CLK low to SYNC high 10 ns 4 5 ns ns THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 Terminal Functions TERMINAL I/O DESCRIPTION NAME NO. AINP 32 I Analog input, single-ended or positive input of differential channel A AINM 31 I Analog input, single-ended or negative input of differential channel A BINP 30 I Analog input, single-ended or positive input of differential channel B BINM 29 I Analog input, single-ended or negative input of differential channel B AVDD 23 I Analog supply voltage AGND 24 I Analog ground BVDD 7 I Digital supply voltage for buffer BGND 8 I Digital ground for buffer CONV_CLK 15 I Digital input. This input is the conversion clock input. CS0 22 I Chip select input (active low) CS1 21 I Chip select input (active high) SYNC 16 O Synchronization output. This signal indicates in a multichannel operation that data of channel A is brought to the digital output and can therefore be used for synchronization. DGND 17 I Digital ground. Ground reference for digital circuitry. DVDD 18 I Digital supply voltage 1−6, 9−12 I/O/Z RA0 13 I Digital input. RA0 is used as an address line for the control register. This is required for writing to the control register 0 and control register 1. See Table 7. RA1 14 I Digital input. RA1 is used as an address line for the control register. This is required for writing to control register 0 and control register 1. See Table 7. REFIN 28 I Common-mode reference input for the analog input channels. It is recommended that this pin be connected to the reference output REFOUT. REFP 26 I Reference input, requires a bypass capacitor of 10 μF to AGND in order to bypass the internal reference voltage. An external reference voltage at this input can be applied. This option can be programmed through control register 0. See Table 8. REFM 25 I Reference input, requires a bypass capacitor of 10 μF to AGND in order to bypass the internal reference voltage. An external reference voltage at this input can be applied. This option can be programmed through control register 0. See Table 8. REFOUT 27 O Analog fixed reference output voltage of 2.5 V. Sink and source capability of 250 μA. The reference output requires a capacitor of 10 μF to AGND for filtering and stability. RD(1) 19 I The RD input is used only if the WR input is configured as a write only input. In this case, it is a digital input, active low as a data read select from the processor. See timing section. WR (R/W)(1) 20 I This input is programmable. It functions as a read-write input R/W and can also be configured as a write-only input WR, which is active low and used as data write select from the processor. In this case, the RD input is used as a read input from the processor. See timing section. D0 – D9 (1) Digital input, output; D0 = LSB The start-conditions of RD and WR (R/W) are unknown. The first access to the ADC has to be a write access to initialize the ADC. 5 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 FUNCTIONAL BLOCK DIAGRAM AVDD DVDD 2.5 V 3.5 V REFP 1.225 V REF 1.5 V REFOUT REFM REFIN AINP VREFM S/H VREFP AINM S/H BINP S/H BINM S/H CONV_CLK CS0 CS1 RD WR (R/W) Logic and Control Single Ended and/or Differential MUX + − BVDD 10 Bit Pipeline ADC 10 Buffers Control Register BGND SYNC AGND 6 D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 RA0 RA1 DGND THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TYPICAL CHARACTERISTICS TOTAL HARMONIC DISTORTION vs SAMPLING FREQUENCY (SINGLE-ENDED) SIGNAL-TO-NOISE AND DISTORTION vs SAMPLING FREQUENCY (SINGLE-ENDED) 80 SINAD − Signal-to-Noise and Distortion − dB THD − Total Harmonic Distortion − dB 90 80 70 60 50 40 AVDD = 5 V, DVDD = BVDD = 3 V, fIN = 500 kHz, AIN = −0.5 dB FS 30 20 0 1 2 3 4 5 6 AVDD = 5 V, DVDD = BVDD = 3 V, fIN = 500 kHz, AIN = −0.5 dB FS 70 60 50 40 30 20 7 0 1 fs − Sampling Frequency − MHz 2 Figure 1 5 6 7 SIGNAL-TO-NOISE vs SAMPLING FREQUENCY (SINGLE-ENDED) 90 80 80 70 AVDD = 5 V, DVDD = BVDD = 3 V, fIN = 500 kHz, AIN = −0.5 dB FS SNR − Signal-to-Noise − dB SFDR − Spurious Free Dynamic Range − dB 4 Figure 2 SPURIOUS FREE DYNAMIC RANGE vs SAMPLING FREQUENCY (SINGLE-ENDED) 70 60 50 40 60 50 40 30 30 20 3 fs − Sampling Frequency − MHz AVDD = 5 V, DVDD = BVDD = 3 V, fIN = 500 kHz, AIN = −0.5 dB FS 0 1 2 3 4 5 fs − Sampling Frequency − MHz Figure 3 6 20 7 0 1 2 3 4 5 6 7 fs − Sampling Frequency − MHz Figure 4 7 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TYPICAL CHARACTERISTICS TOTAL HARMONIC DISTORTION vs SAMPLING FREQUENCY (DIFFERENTIAL) SIGNAL-TO-NOISE AND DISTORTION vs SAMPLING FREQUENCY (DIFFERENTIAL) 80 SINAD − Signal-to-Noise and Distortion − dB THD − Total Harmonic Distortion − dB 90 80 70 60 50 40 30 20 AVDD = 5 V, DVDD = BVDD = 3 V, fIN = 500 kHz, AIN = −0.5 dB FS 0 1 2 3 4 5 6 70 60 50 40 30 20 7 AVDD = 5 V, DVDD = BVDD = 3 V, fIN = 500 kHz, AIN = −0.5 dB FS 0 1 fs − Sampling Frequency − MHz 2 Figure 5 6 7 80 AVDD = 5 V, DVDD = BVDD = 3 V, fIN = 500 kHz, AIN = −0.5 dB FS 90 AVDD = 5 V, DVDD = BVDD = 3 V, fIN = 500 kHz, AIN = −0.5 dB FS 70 SNR − Signal-to-Noise − dB SFDR − Spurious Free Dynamic Range − dB 5 SIGNAL-TO-NOISE vs SAMPLING FREQUENCY (DIFFERENTIAL) 100 80 70 60 60 50 40 30 50 20 0 1 2 3 4 5 fs − Sampling Frequency − MHz Figure 7 8 4 Figure 6 SPURIOUS FREE DYNAMIC RANGE vs SAMPLING FREQUENCY (DIFFERENTIAL) 40 3 fs − Sampling Frequency − MHz 6 7 0 1 2 3 4 5 fs − Sampling Frequency − MHz Figure 8 6 7 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TYPICAL CHARACTERISTICS TOTAL HARMONIC DISTORTION vs INPUT FREQUENCY (SINGLE-ENDED) 80 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −1 dB FS 80 SINAD − Signal-to-Noise and Distortion − dB THD − Total Harmonic Distortion − dB 90 SIGNAL-TO-NOISE AND DISTORTION vs INPUT FREQUENCY (SINGLE-ENDED) 70 60 50 40 30 20 0 1 2 3 4 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −1 dB FS 70 60 50 40 30 20 fi − Input Frequency − MHz 0 1 SIGNAL-TO-NOISE vs INPUT FREQUENCY (SINGLE-ENDED) 80 90 75 80 70 SNR − Signal-to-Noise − dB SFDR − Spurious Free Dynamic Range − dB 4 Figure 10 SPURIOUS FREE DYNAMIC RANGE vs INPUT FREQUENCY (SINGLE-ENDED) 60 3 fi − Input Frequency − MHz Figure 9 70 2 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −1 dB FS 50 40 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −1 dB FS 65 60 55 50 45 40 35 30 30 25 20 0.0 0.5 1.0 1.5 2.0 2.5 fi − Input Frequency − MHz Figure 11 3.0 3.5 20 0.0 0.5 1.0 1.5 2.0 2.5 fi − Input Frequency − MHz 3.0 3.5 Figure 12 9 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TYPICAL CHARACTERISTICS SIGNAL-TO-NOISE AND DISTORTION vs INPUT FREQUENCY (DIFFERENTIAL) TOTAL HARMONIC DISTORTION vs INPUT FREQUENCY (DIFFERENTIAL) 80 80 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −0.5 dB FS SINAD − Signal-to-Noise and Distortion − dB THD − Total Harmonic Distortion − dB 90 70 60 50 40 30 20 0.0 0.5 1.0 1.5 2.0 2.5 3.0 70 60 50 40 30 20 0.0 3.5 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −0.5 dB FS 0.5 fi − Input Frequency − MHz SPURIOUS FREE DYNAMIC RANGE vs INPUT FREQUENCY (DIFFERENTIAL) 2.5 3.0 3.5 80 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −0.5 dB FS 80 70 SNR − Signal-to-Noise − dB SFDR − Spurious Free Dynamic Range − dB 2.0 SIGNAL-TO-NOISE vs INPUT FREQUENCY (DIFFERENTIAL) 90 70 60 50 40 30 0.5 1.0 1.5 2.0 2.5 Figure 15 3.0 60 50 40 30 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −0.5 dB FS fi − Input Frequency − MHz 10 1.5 Figure 14 Figure 13 20 0.0 1.0 fi − Input Frequency − MHz 3.5 20 0.0 0.5 1.0 1.5 2.0 2.5 fi − Input Frequency − MHz Figure 16 3.0 3.5 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TYPICAL CHARACTERISTICS EFFECTIVE NUMBER OF BITS vs SAMPLING FREQUENCY (SINGLE-ENDED) EFFECTIVE NUMBER OF BITS vs SAMPLING FREQUENCY (DIFFERENTIAL) 12 AVDD = 5 V, DVDD = BVDD = 3 V, fin = 500 kHz, AIN = −0.5 dB FS ENOB − Effective Number of Bits − Bits ENOB − Effective Number of Bits − Bits 12 11 10 9 8 7 6 0 1 2 3 4 5 6 AVDD = 5 V, DVDD = BVDD = 3 V, fin = 500 kHz, AIN = −0.5 dB FS 11 10 9 8 7 6 7 0 1 2 fs − Sampling Frequency − MHz EFFECTIVE NUMBER OF BITS vs INPUT FREQUENCY (SINGLE-ENDED) ENOB − Effective Number of Bits − Bits ENOB − Effective Number of Bits − Bits 6 7 12 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −1 dB FS 10 9 8 7 0.0 5 EFFECTIVE NUMBER OF BITS vs INPUT FREQUENCY (DIFFERENTIAL) 12 6 4 Figure 18 Figure 17 11 3 fs − Sampling Frequency − MHz 0.5 1.0 1.5 2.0 2.5 fi − Input Frequency − MHz Figure 19 3.0 3.5 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −0.5 dB FS 11 10 9 8 7 6 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 fi − Input Frequency − MHz Figure 20 11 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TYPICAL CHARACTERISTICS DIFFERENTIAL NONLINEARITY vs TEMPERATURE INTEGRAL NONLINEARITY vs TEMPERATURE 0.70 0.66 0.64 0.68 DNL − Differential Nonlinearity − LSB INL − Integral Nonlinearity − LSB 0.68 0.70 AVDD = 5 V, BVDD = DVDD = 3.3 V, Differential Mode, Internal Reference, Internal Oscillator 0.62 0.60 0.58 0.56 0.54 0.52 0.50 −40 −15 10 35 60 85 0.66 0.64 0.62 0.60 0.58 0.56 0.54 AVDD = 5 V, BVDD = DVDD = 3.3 V, Differential Mode, Internal Reference, Internal Oscillator 0.52 0.50 −40 −15 TA − Temperature − °C Figure 21 Figure 22 GAIN vs INPUT FREQUENCY (SINGLE-ENDED) 5 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −0.5 dB FS 0 G − Gain − dB −5 −10 −15 −20 −25 −30 0 10 20 30 40 50 60 70 80 90 100 110 120 fi − Input Frequency − MHz Figure 23 12 10 35 TA − Temperature − °C 60 85 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TYPICAL CHARACTERISTICS FAST FOURIER TRANSFORM (4096 POINTS) (SINGLE-ENDED) vs FREQUENCY 0 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −0.5 dB FS, fin = 1 MHz Magnitude − dB −20 −40 −60 −80 −100 −120 −140 0.0 0.5 1.0 1.5 2.0 2.5 3.0 f − Frequency − MHz Figure 24 FAST FOURIER TRANSFORM (4096 POINTS) (DIFFERENTIAL) vs FREQUENCY 0 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 6 MSPS, AIN = −0.5 dB FS, fin = 1 MHz Magnitude − dB −20 −40 −60 −80 −100 −120 −140 0.0 0.5 1.0 1.5 2.0 2.5 3.0 f − Frequency − MHz Figure 25 13 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TYPICAL CHARACTERISTICS DNL − Differential Nonlinearity − LSB DIFFERENTIAL NONLINEARITY vs ADC CODE 1.0 0.8 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 8 MSPS 0.6 0.4 0.2 0.0 −0.2 −0.4 −0.6 −0.8 −1.0 0 256 512 768 1024 ADC Code Figure 26 INL − Integral Nonlinearity − LSB INTEGRAL NONLINEARITY vs ADC CODE 1.0 0.8 0.6 AVDD = 5 V, DVDD = BVDD = 3 V, fs = 8 MSPS 0.4 0.2 0.0 −0.2 −0.4 −0.6 −0.8 −1.0 0 256 512 ADC Code Figure 27 14 768 1024 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 DETAILED DESCRIPTION Reference Voltage The THS1007 has a built-in reference, which provides the reference voltages for the ADC. VREFP is set to 3.5 V and VREFM is set to 1.5 V. An external reference can also be used through two reference input pins, REFP and REFM, if the reference source is programmed as external. The voltage levels applied to these pins establish the upper and lower limits of the analog inputs to produce a full-scale and zero-scale reading respectively. Analog Inputs The THS1007 consists of 4 analog inputs, which are sampled simultaneously. These inputs can be selected individually and configured as single-ended or differential inputs. The desired analog input channel can be programmed. Converter The THS1007 uses a 10-bit pipelined multistaged architecture, which achieves a high sample rate with low power consumption. The THS1007 distributes the conversion over several smaller ADC sub-blocks, refining the conversion with progressively higher accuracy as the device passes the results from stage to stage. This distributed conversion requires a small fraction of the number of comparators used in a traditional flash ADC. A sample-and-hold amplifier (SHA) within each of the stages permits the first stage to operate on a new input sample while the second through the eighth stages operate on the seven preceding samples. Conversion Clock An external clock signal with a duty cycle of 50% has to be applied to the clock input (CONV_CLK). A new conversion is started with every falling edge of the applied clock signal. The conversion values are available at the output with a latency of 5 clock cycles. SYNC In multichannel mode, the first SYNC signal is delayed by [7+ (# Channels Sampled)] cycles of the CONV_CLK after a SYNC reset. This is due to the latency of the pipeline architecture of the THS1007. Sampling Rate The maximum possible conversion rate per channel is dependent on the selected analog input channels. Table 1 shows the maximum conversion rate for different combinations. Table 1. Maximum Conversion Rate in Continuous Conversion Mode NUMBER OF CHANNELS MAXIMUM CONVERSION RATE PER CHANNEL 1 single-ended channel 1 6 MSPS 2 single-ended channels 2 3 MSPS 3 single-ended channels 3 2 MSPS 4 single-ended channels 4 1.5 MSPS 1 differential channel 1 6 MSPS 2 differential channels 2 3 MSPS 1 single-ended and 1 differential channel 2 3 MSPS 2 single-ended and 1 differential channels 3 2 MSPS CHANNEL CONFIGURATION The maximum conversion rate per channel, fc, is given by: fc + 6 MSPS # channels 15 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 Conversion During conversion, the ADC operates with a free running external clock applied to the input CONV_CLK. With every falling edge of the CONV_CLK signal a new converted value is available to the data bus with the corresponding read signal. The THS1007 allows up to four analog inputs to be selected. The inputs can be configured as two differential channels, four single-ended channels or a combination of differential and signle-ended. To provide the system with channel information, the THS1007 utilizes an active low SYNC signal. When operated in a multichannel configuration, the SYNC signal is active low when data from channel 1 is available to the databus. When operated in signle-channel mode (single-ended or differential operation) the SYNC signal is disabled. Figure 28 shows the timing of the conversion, when one analog input channel is selected. The maximum throughput rate is 6 MSPS in this mode. The signal SYNC is disabled for the selection of one analog input since this information is not necessary. There is a certain timing relationship required for the read signal with respect to the conversion clock. This can be seen in Figure 28 and the timing specifications. A more detailed description of the timing is given in the timing section and signal description of the THS1007. Sample N Channel 1 Sample N+1 Channel 1 Sample N+2 Channel 1 Sample N+3 Channel 1 Sample N+4 Channel 1 Sample N+5 Channel 1 Sample N+6 Channel 1 AIN td(A) td(pipe) tw(CONV_CLKH) tw(CONV_CLKL) CONV_CLK tc tsu(READH-CONV_CLKL) tsu(CONV_CLKL-READL) READ† Data N−4 Channel 1 †READ Data N−3 Channel 1 Data N−2 Channel 1 Data N−1 Channel 1 Data N Channel 1 Data N+1 Channel 1 Data N+2 Channel 1 is the logical combination from CS0, CS1 and RD Figure 28. Conversion Timing in 1-Channel Operation Figure 29 shows the conversion timing when two analog input channels are selected. The maximum throughput rate per channel is 3 MSPS in this mode. The data flow in the bottom of the figure shows the order the converted data is available to the data bus. The SYNC pulse is active low when the data of channel one is available to the databus. The data of channel one is followed by the data of channel two before the SYNC signal is active low again. 16 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 Sample N+1 Channel 1, 2 Sample N Channel 1, 2 AIN Sample N+3 Channel 1, 2 Sample N+2 Channel 1, 2 td(A) td(pipe) tw(CONV_CLKH) tw(CONV_CLKL) CONV_CLK tc tsu(CONV_CLKL-READL) tsu(READH-CONV_CLKL) READ† td(CONV_CLKL-SYNCL) td(CONV_CLKL-SYNCH) SYNC Data N−2 Channel 1 †READ Data N−2 Channel 2 Data N−1 Channel 1 Data N−1 Channel 2 Data N Channel 1 Data N Channel 2 Data N+1 Channel 1 is the logical combination from CS0, CS1 and RD Figure 29. Conversion Timing in 2-Channel Operation Figure 30 shows the conversion timing when three analog input channels are selected. The maximum throughput rate per channel is 2 MSPS in this mode. The data flow in the bottom of the figure shows in which order the converted data is available to the data bus. The SYNC signal is active low when the data of channel one is available to the data bus. The data of channel one is followed by the data of channel two and channel three before channel one is again available and the SYNC signal is active low. Sample N Channel 1, 2, 3 Sample N+1 Channel 1, 2, 3 Sample N+2 Channel 1, 2, 3 AIN td(A) td(pipe) tw(CONV_CLKH) tw(CONV_CLKL) CONV_CLK tc tsu(CONV_CLKL-READL) tsu(READH-CONV_CLKL) READ† td(CONV_CLKL-SYNCH) td(CONV_CLKL-SYNCL) SYNC Data N−2 Channel 3 †READ Data N−1 Channel 1 Data N−1 Channel 2 Data N−1 Channel 3 Data N Channel 1 Data N Channel 2 Data N Channel 3 is the logical combination from CS0, CS1 and RD Figure 30. Conversion Timing in 3-Channel Operation 17 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 Figure 31 shows the conversion timing when four analog input channels are selected. The maximum throughput rate per channel is 1.5 MSPS in this mode. The data flow in the bottom of the figure shows in which order the converted data is available to the databus. The SYNC signal is active low when the data of channel one is available to the data bus. The data of channel one is followed by the data of channel two, the data of channel three and the data of channel four before channel one is again available to the databus and SYNC is active low. Sample N Channel 1, 2, 3, 4 Sample N+1 Channel 1, 2, 3, 4 AIN td(A) td(pipe) tw(CONV_CLKH) tw(CONV_CLKL) CONV_CLK tc tsu(READH-CONV_CLKL) tsu(CONV_CLKL-READL) READ† tsu(CONV_CLKL-SYNCH) tsu(CONV_CLKL-SYNCL) SYNC Data N−1 Channel 1 †READ Data N−1 Channel 2 Data N−1 Channel 3 Data N−1 Channel 4 Data N Channel 1 Data N Channel 2 is the logical combination from CS0, CS1 and RD Figure 31. Timing of Continuous Conversion Mode (4-channel operation) 18 Data N Channel 3 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 DIGITAL OUTPUT DATA FORMAT The digital output data format of the THS1007 can either be in binary format or in twos complement format. The following tables list the digital outputs for the analog input voltages. Table 2. Binary Output Format for Single-Ended Configuration SINGLE-ENDED, BINARY OUTPUT ANALOG INPUT VOLTAGE DIGITAL OUTPUT CODE AIN = VREFP 3FFh AIN = (VREFP + VREFM)/2 200h AIN = VREFM 000h Table 3. Two’s Complement Output Format for Single-Ended Configuration SINGLE-ENDED, TWOS COMPLEMENT ANALOG INPUT VOLTAGE DIGITAL OUTPUT CODE AIN = VREFP 1FFh AIN = (VREFP + VREFM)/2 000h AIN = VREFM 200h Table 4. Binary Output Format for Differential Configuration DIFFERENTIAL, BINARY OUTPUT ANALOG INPUT VOLTAGE DIGITAL OUTPUT CODE Vin = AINP − AINM VREF = VREFP − VREFM Vin = VREF 3FFh Vin = 0 200h Vin = −VREF 000h Table 5. Two’s Complement Output Format for Differential Configuration DIFFERENTIAL, BINARY OUTPUT ANALOG INPUT VOLTAGE DIGITAL OUTPUT CODE Vin = AINP − AINM VREF = VREFP − VREFM Vin = VREF 1FFh Vin = 0 000h Vin = −VREF 200h 19 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 ADC CONTROL REGISTER The THS1007 contains two 10-bit wide control registers (CR0, CR1) in order to program the device into the desired mode. The bit definitions of both control registers are shown in 6. Table 6. Bit Definitions of Control Register CR0 and CR1 REG BIT 9 BIT 8 BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CR0 TEST1 TEST0 SCAN DIFF1 DIFF0 CHSEL1 CHSEL0 PD RES VREF CR1 RESERVED OFFSET BIN/2’s R/W RES RES RES RES SRST RESET Writing to Control Register 0 and Control Register 1 The 10-bit wide control register 0 and control register 1 can be programmed by addressing the desired control register and writing the register value to the ADC. The addressing is performed with the upper bits RA0 and RA1. During this write process, the data bits D0 to D9 contain the desired control register value. Table 7 shows the addressing of each control register. Table 7. Control Register Addressing 20 D0 – D9 RA0 RA1 Addressed Control Register Desired register value 0 0 Control register 0 Desired register value 1 0 Control register 1 Desired register value 0 1 Reserved for future Desired register value 1 1 Reserved for future THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 INITIALIZATION OF THE THS1007 The initialization of the THS1007 should be done according to the configuration flow shown in Figure 32. Start Use Default Values? No Yes Write 0x401 to THS1007 (Set Reset Bit in CR1) Write 0x401 to THS1007 (Set Reset Bit in CR1) Clear RESET By Writing 0x400 to CR1 Clear RESET By Writing 0x400 to CR1 Write the User Configuration to CR0 Write the User Configuration to CR1 ( Must Exclude RESET) Continue Figure 32. THS1007 Configuration Flow 21 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 ADC CONTROL REGISTERS Control Register 0, Write Only (see Table 7) BIT 11 BIT 10 BIT 9 BIT 8 BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 0 0 TEST1 TEST0 SCAN DIFF1 DIFF0 CHSEL1 CHSEL0 PD RES VREF Table 8. Control Register 0 Bit Functions BITS RESET VALUE NAME 0 0 VREF Vref select: Bit 0 = 0 → The internal reference is selected Bit 0 = 1 → The external reference voltage is used for the ADC 1 0 RES RESERVED 2 0 PD 3, 4 0,0 CHSEL0, CHSEL1 5,6 1,0 DIFF0, DIFF1 7 0 SCAN Autoscan enable Bit 7 enables or disables the autoscan function of the ADC. Refer to Table 9. 8,9 0,0 TEST0, TEST1 Test input enable Bit 8 and bit 9 control the test function of the ADC. Three different test voltages can be measured. This feedback allows the check of all hardware connections and the ADC operation. FUNCTION Power down. Bit 2 = 0 → The ADC is active Bit 2 = 1 → Power down The reading and writing to and from the digital outputs is possible during power down. Channel select Bit 3 and bit 4 select the analog input channel of the ADC. Refer to Table 9. Number of differential channels Bit 5 and bit 6 contain information about the number of selected differential channels. Refer to Table 9. Refer to Table 10 for selection of the three different test voltages. 22 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 ANALOG INPUT CHANNEL SELECTION The analog input channels of the THS1007 can be selected via bits 3 to 7 of control register 0. One single channel (single-ended or differential) is selected via bit 3 and bit 4 of control register 0. Bit 5 controls the selection between single-ended and differential configuration. Bit 6 and bit 7 select the autoscan mode, if more than one input channel is selected. Table 10 shows the possible selections. Table 9. Analog Input Channel Configurations BIT 7 SCAN BIT 6 DIFF1 BIT 5 DIFF0 BIT 4 CHSEL1 BIT 3 CHSEL0 0 0 0 0 0 Analog input AINP (single ended) 0 0 0 0 1 Analog input AINM (single ended) 0 0 0 1 0 Analog input BINP (single ended) 0 0 0 1 1 Analog input BINM (single ended) 0 0 1 0 0 Differential channel (AINP−AINM) 0 0 1 0 1 Differential channel (BINP−BINM) 1 0 0 0 1 Autoscan two single ended channels: AINP, AINM, AINP, … 1 0 0 1 0 Autoscan three single ended channels: AINP, AINM, BINP, AINP, … 1 0 0 1 1 Autoscan four single ended channels: AINP, AINM, BINP, BINM, AINP, … 1 0 1 0 1 Autoscan one differential channel and one single ended channel AINP, (BINP−BINM), AINP, (BINP−BINM), … 1 0 1 1 0 Autoscan one differential channel and two single ended channel AINP, AINM, (BINP−BINM), AINP, … 1 1 0 0 1 Autoscan two differential channels (AINP−AINM), (BINP−BINM), (AINP−AINM), … 0 0 1 1 0 Reserved 0 0 1 1 1 Reserved 1 0 0 0 0 Reserved 1 0 1 0 0 Reserved 1 0 1 1 1 Reserved 1 1 0 0 0 Reserved 1 1 0 1 0 Reserved 1 1 0 1 1 Reserved 1 1 1 0 0 Reserved 1 1 1 0 1 Reserved 1 1 1 1 0 Reserved 1 1 1 1 1 Reserved DESCRIPTION OF THE SELECTED INPUTS 23 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 Test Mode The test mode of the ADC is selected via bit 8 and bit 9 of control register 0. The different selections are shown in Table 10. Table 10. Test Mode BIT 9 TEST1 BIT 8 TEST0 OUTPUT RESULT 0 0 Normal mode 0 1 VREFP 1 0 ((VREFM)+(VREFP))/2 1 1 VREFM Three different options can be selected. This feature allows support testing of hardware connections between the ADC and the processor. Control Register 1, Write Only (see Table 7) BIT 11 BIT10 BIT 9 BIT 8 BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 0 1 RESERVED OFFSET BIN/2s R/W RES RES RES RES SRST RESET Table 11. Control Register 1 Bit Functions BITS RESET VALUE NAME 0 0 RESET FUNCTION Reset Writing a 1 into this bit resets the device and sets the control register 0 and control register 1 to the reset values. To bring the device out of RESET, a 0 has to be written into this bit. 1 0 SRST Writing a 1 into this bit resets the sync generator. When running in multichannel mode, this must be set during the configuration cycle. 2, 3 0,0 RES Reserved 4 1 RES Reserved 5 1 RES Reserved 6 0 R/W R/W, RD/WR selection Bit 6 of control register 1 controls the function of the inputs RD and WR. When bit 6 in control register 1 is set to 1, WR becomes a R/W input and RD is disabled. From now on a read is signalled with R/W high and a write with R/W as a low signal. If bit 6 in control register 1 is set to 0, the input RD becomes a read input and the input WR becomes a write input. 7 0 BIN/2s Complement select If bit 7 of control register 1 is set to 0, the output value of the ADC is in twos complement. If bit 7 of control register 1 is set to 1, the output value of the ADC is in binary format. Refer to Table 2 through Table 5. 8 0 OFFSET Offset cancellation mode Bit 8 = 0 → normal conversion mode Bit 8 = 1 → offset calibration mode If a 1 is written into bit 8 of control register 1, the device internally sets the inputs to zero and does a conversion. The conversion result is stored in an offset register and subtracted from all conversions in order to reduce the offset error. 9 24 0 RESERVED Always write 0. THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 TIMING AND SIGNAL DESCRIPTION OF THE THS1007 The reading from the THS1007 and writing to the THS1007 is performed by using the chip select inputs (CS0, CS1), the write input WR and the read input RD. The write input is configurable to a combined read/write input (R/W). This is desired in cases where the connected processor consists of a combined read/write output signal (R/W). The two chip select inputs can be used to interface easily to a processor. Reading from the THS1007 takes place by an internal RDint signal, which is generated from the logical combination of the external signals CS0, CS1 and RD (see Figure 33). This signal is then used to strobe the words and to enable the output buffers. The last external signal (either CS0, CS1 or RD) to become valid makes RDint active while the write input (WR) is inactive. The first of those external signals switching to its inactive state deactivates RDint again. Writing to the THS1007 takes place by an internal WRint signal, which is generated from the logical combination of the external signals CS0, CS1 and WR. This signal strobes the control words into the control registers 0 and 1. The last external signal (either CS0, CS1 or WR) to become valid switches WRint active while the read input (RD) is inactive. The first of those external signals going to its inactive state deactivates WRint again. CS0 RD CS1 RD WR WR Control/Data Registers Data Bits Figure 33. Logical Combination of CS0, CS1, RD, and WR 25 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 Read Timing (using R/W, CS0-controlled) Figure 34 shows the read-timing behavior when the WR(R/W) input is programmed as a combined read-write input R/W. The RD input has to be tied to high-level in this configuration. This timing is called CS0-controlled because CS0 is the last external signal of CS0, CS1, and R/W which becomes valid. The reading of the data should be done with a certain timing relative to the conversion clock CONV_CLK, as illustrated in Figure 34. t su(CS0H−CONV_CLKL) t su(CONV_CLKL−CS0L) CONV_CLK 10% 10% tw(CS) CS0 10% 90% 10% CS1 ÓÓÓÓ ÓÓÓÓ R/W th(R/W) tsu(R/W) 90% ÔÔÔÔ ÔÔÔÔ 90% RD t t a h 90% 90% D(O−11) Figure 34. Read Timing Diagram Using R/W (CS0-controlled) Read Timing Parameter (CS0-controlled) † PARAMETER MIN TYP MAX UNIT tsu(CONV_CLKL−CSOL) Setup time, CONV_CLK low before CS valid 10 ns tsu(CSOH−CONV_CLKL) Setup time, CS invalid to CONV_CLK low 20 ns tsu(R/W) Setup time, R/W high to last CS valid 0 ns ta Access time, last CS valid to data valid 0 10 ns th Hold time, first CS invalid to data invalid 0 5 ns th(R/W) Hold time, first external CS invalid to R/W change tw(CS) Pulse duration, CS active 26 5 ns 10 ns THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 Write Timing (using R/W, CS0-controlled) Figure 35 shows the write-timing behavior when the WR(R/W) input is programmed as a combined read-write input R/W. The RD input has to be tied to high-level in this configuration. This timing is called CS0-controlled because CS0 is the last external signal of CS0, CS1, and R/W which becomes valid. The write into the THS1007 can be performed irrespective of the conversion clock signal CONV_CLK. tw(CS) CS0 90% 10% 10% tsu(R/W) th(R/W) CS1 R/W ÔÔÔ ÔÔÔ 10% ÓÓÓ ÓÓÓ 10% RD tsu th 90% 90% D(0−11) Figure 35. Write Timing Diagram Using R/W (CS0-controlled) Read Timing Parameter (CS0-controlled) † PARAMETER MIN TYP MAX UNIT tsu(R/W) Setup time, R/W stable to last CS valid 0 ns tsu Setup time, data valid to first CS invalid 5 ns th Hold time, first CS invalid to data invalid 2 ns th(R/W) Hold time, first CS invalid to R/W change 5 ns tw(CS) Pulse duration, CS active 10 ns 27 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 ANALOG INPUT CONFIGURATION AND REFERENCE VOLTAGE The THS1007 features four analog input channels. These can be configured for either single-ended or differential operation. Figure 36 shows a simplified model, where a single-ended configuration for channel AINP is selected. The reference voltages for the ADC itself are VREFP and VREFM (either internal or external reference voltage). The analog input voltage range is between VREFM to VREFP. This means that VREFM defines the minimum voltage, and VREFP defines the maximum voltage, which can be applied to the ADC. The internal reference source provides the voltage VREFM of 1.5 V and the voltage VREFP of 3.5 V (see also section reference voltage). The resulting analog input voltage swing of 2 V can be expressed by: V REFM v AINP v V (1) REFP VREFP 10-Bit ADC AINP VREFM Figure 36. Single-Ended Input Stage A differential operation is desired in many applications due to a better signal-to-noise ration. Figure 37 shows a simplified model for the analog inputs AINM and AINP, which are configured for differential operation. The differential operation mode provides in terms of performance benefits over the single-ended mode and is therefore recommended for best performance. The THS1007 offers 2 differential analog inputs and in the single-ended mode4 analog inputs. If the analog input architecture is different, common-mode voltages can be rejected. Additional details for both modes are given below. AINP VREFP + Σ VADC 10-Bit ADC − AINM VREFM Figure 37. Differential Input Stage In comparison to the single-ended configuration it can be seen that the voltage VADC, which is applied at the input of the ADC, is the difference between the input AINP and AINM. The voltage VADC can be calculated as follows: V ADC + ABS(AINP–AINM) (2) An advantage to single-ended operation is that the common-mode voltage V CM + AINM ) AINP 2 (3) can be rejected in the differential configuration, if the following condition for the analog input voltages is true: AGND v AINM, AINP v AV 1VvV CM DD v4V (4) (5) SINGLE-ENDED MODE OF OPERATION The THS1007 can be configured for single-ended operation using dc or ac coupling. In either case, the input of the THS1007 must be driven from an operational amplifier that does not degrade the ADC performance. Because the THS1007 operates from a 5-V single supply, it is necessary to level-shift ground-based bipolar signals to comply with its input requirements. This can be achieved with dc and ac-coupling. 28 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 DC COUPLING An operational amplifier can be configured to shift the signal level according to the analog input voltage range of the THS1007. The analog input voltage range of the THS1007 goes from 1.5 V to 3.5 V. An operational amplifier can be used as shown in Figure 38. Figure 38 shows an example with the analog input signal in the range between −1 V up to 1 V. This signal is shifted by an operational amplifier to the analog input range of the THS1007 (1.5 V to 3.5 V). The operational amplifier is configured as an inverting amplifier with a gain of −1. The required dc voltage of 1.25 V at the noninverting input is derived from the 2.5-V output reference REFOUT of the THS1007 by using a resistor divider. Therefore, the operational amplifier output voltage is centered at 2.5 V. The 10 μF tantalum capacitor is required for bypassing REFOUT. REFIN of the THS1007 must be connected directly to REFOUT in single-ended mode. The use of ratio matched, thin-film resistor networks minimizes gain and offset errors. R1 1V 0V −1 V R1 1.25 V 3.5 V 2.5 V 1.5 V 5V _ THS1007 RS AINP + C REFIN REFOUT R2 + 10 μF R2 Figure 38. Level-Shift for DC-Coupled Input DIFFERENTIAL MODE OF OPERATION For the differential mode of operation, a conversion from single-ended to differential is required. A conversion to differential signals can be achieved by using an RF-transformer, which provides a center tap. Best performance is achieved in differential mode. Mini Circuits T4−1 49.9 Ω THS1007 R 200 Ω AINP C R AINM C 10 μF + REFOUT Figure 39. Transformer Coupled Input 29 THS1007 www.ti.com SLAS286B − AUGUST 2000− REVISED DECEMBER 2010 DEFINITIONS OF SPECIFICATIONS AND TERMINOLOGY Integral Nonlinearity Integral nonlinearity refers to the deviation of each individual code from a line drawn from zero through full scale. The point used as zero occurs 1/2 LSB before the first code transition. The full-scale point is defined as level 1/2 LSB beyond the last code transition. The deviation is measured from the center of each particular code to the true straight line between these two points. Differential Nonlinearity An ideal ADC exhibits code transitions that are exactly 1 LSB apart. DNL is the deviation from this ideal value. A differential nonlinearity error of less than ±1 LSB ensures no missing codes. Zero Offset The major carry transition should occur when the analog input is at zero volts. Zero error is defined as the deviation of the actual transition from that point. Gain Error The first code transition should occur at an analog value 1/2 LSB above negative full scale. The last transition should occur at an analog value 1 1/2 LSB below the nominal full scale. Gain error is the deviation of the actual difference between first and last code transitions and the ideal difference between first and last code transitions. Signal-to-noise Ratio + Distortion (SINAD) SINAD is the ratio of the rms value of the measured input signal to the rms sum of all other spectral components below the Nyquist frequency, including harmonics but excluding dc. The value for SINAD is expressed in decibels. Effective Number of Bits (ENOB) For a sine wave, SINAD can be expressed in terms of the number of bits. Using the following formula, N+ (SINAD * 1.76) 6.02 it is possible to get a measure of performance expressed as N, the effective number of bits. Thus, the effective number of bits for a device for sine wave inputs at a given input frequency can be calculated directly from its measured SINAD. Total Harmonic Distortion (THD) THD is the ratio of the rms sum of the first six harmonic components to the rms value of the measured input signal and is expressed as a percentage or in decibels. Spurious Free Dynamic Range (SFDR) SFDR is the difference in dB between the rms amplitude of the input signal and the peak spurious signal. 30 PACKAGE OPTION ADDENDUM www.ti.com 10-Dec-2020 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) THS1007CDA ACTIVE TSSOP DA 32 46 RoHS & Green NIPDAU Level-2-260C-1 YEAR 0 to 70 THS1007 THS1007IDA ACTIVE TSSOP DA 32 46 RoHS & Green NIPDAU Level-2-260C-1 YEAR -40 to 85 THS1007I (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
THS1007IDA 价格&库存

很抱歉,暂时无法提供与“THS1007IDA”相匹配的价格&库存,您可以联系我们找货

免费人工找货