Using the UCC25230EVM-754
User's Guide
Literature Number: SLUU670
November 2011
User's Guide
SLUU670 – November 2011
1.5-W Forward-Flyback DC-to-DC Converter for 48-V
Telecom Biasing Supply
1
Introduction
This EVM is to help evaluate the UCC25230 PWM device in a forward-flyback or flyback DC-to-DC
converter topology for a 48-V telecom biasing supply. The targeted application is telecom module design
with nominal 48-V input. The EVM is a dual-output converter. Each channel is nominal 12 V and 65 mA for
a total output power of 1.5 W. The design is made on a small footprint and low profile, the effective circuit
area for the bias portion is 0.6 in x 0.5 in x 0.15 in (L x W x H). The UCC25230 is a highly integrated PWM
controller operating as an isolated forward flyback. It has integrated high-side and low-side power switches
and a control circuit with all key converter functions included.
2
Description
The EVM is a 1.5-W forward-flyback DC-to-DC converter that accepts an input range of 36 V to 72 V DC
and converts it to two regulated output voltages, nominally 12 V and maximum 65-mA load current for
each channel. The two outputs are 1500-V level isolated from each other, with one channel on the primary
side and the other on the secondary side.
2.1
Typical Applications
•
•
•
•
•
2.2
Features
•
•
•
•
•
•
•
•
2
Biasing Power to Power on the Main Controller (whether on the primary or the secondary side of the
isolation barrier)
48-V Telecom
Server Systems
Datacom
DSP’s, ASIC’s, and FPGA’s
Start Up Directly from Telecom Input Voltage 36 V to 72 V DC
Two Regulated 12-V Outputs, 65-mA Maximum Load Current
Telecom Isolation from Primary-to-Secondary 1500 V
Small Footprint and Low Profile Design
Output Voltage Regulation (from no load to full load, and from low line to high line)
Input Voltage Status Signal, (manually or automatically set up)
Device Evaluation Test Points
All Surface Mount Components and Industry Leading-Edge Small Footprint
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
SLUU670 – November 2011
Submit Documentation Feedback
Electrical Performance Specifications
www.ti.com
3
Electrical Performance Specifications
Table 1. UCC25230EVM-754 Electrical Performance Specifications
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Input Characteristics
Voltage range
Maximum input current
36
VIN = 36 V and IOUT1 = IOUT2 = 65 mA
48
72
70
No load input current
V
mA
8.5
Output Characteristics
Output voltage, VOUT1
Output voltage, VOUT2
IOUT1 = 0 mA, IOUT2 = 65 mA
11.5
11.8
12.5
IOUT1 = 65 mA, IOUT2 = 0 mA
11.5
11.8
12.5
IOUT1 = 0 mA, IOUT2 = 100 mA
9.5
10.0
11.0
IOUT1 = 100 mA, IOUT2 = 0 mA
9.5
12.0
12.5
Output load current, IOUT2 or
IOUT2
Output-1 voltage regulation
(regulated output)
Output-2 voltage regulation
(cross-regulated output)
65
Line regulation: input voltage = 36 V to 72 V
IOUT1 = IOUT2 = 100 mA
10
Load regulation: input voltage = 48 V
IOUT1 = 0 mA to 100 mA
IOUT2 = 100 mA
10
Line regulation: input voltage = 36V to 72V
IOUT1 = IOU2 = 65 mA
0.75
Load regulation: input voltage = 48 V
IOUT1 = 65 mA
IOUT2 = 0 mA to 65 mA
Output voltage ripple
Output-1 and -2
V
mA
mV
V
-1.35
At IOUT1 = IOUT2 = 65 mA
45
60
mVpp
Systems Characteristics
Switching frequency
380
Peak efficiency
VIN = 36 V, IOUT1 = IOUT2 = 50 mA
Full load efficiency
VIN = 48 V, IOUT1 = IOUT2 = 65 mA
Input status good (TP4)
Operating temperature
kHz
81%
80%
4.2
5.2
V
45
ºC
Natural convection
NOTE: Effective bias real-estate size, L x W x H = 0.6 in x 0.5 in x 0.15 in and a board size of L x W
= 2.2 in x 1.4 in.
SLUU670 – November 2011
Submit Documentation Feedback
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
3
Schematic
VIN_G
Schematic
VIN_G Good ON
4
www.ti.com
Figure 1. UCC25230EVM-754 Schematic
4
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
SLUU670 – November 2011
Submit Documentation Feedback
Test Setup
www.ti.com
5
Test Setup
5.1
Test Equipment
Voltage Source: Vsc1, the input voltage shall be a variable DC source capable of supplying up to 72 VDC
at no less than 0.35 ADC, and connected to J1 and Ams1 as shown in Figure 2.
Multimeters:
• Ams1: IIN, 0 mADC to 100 mADC, ammeter, four digits display.
• Vms1: VIN, 0-V to 75-V voltmeter, three and half digits display.
• Vm1: VOUT1, 0-V to 13-V voltmeter, three and half digits display.
• Vm2: VOUT2, 0-V to 13-V voltmeter, three and half digits display.
Output Load (Load-1 and Load-2):Electronic, 0 mADC to 200 mADC (2 units), For the output load on
VOUT1 and VOUT2, a programmable electronic load capable of sinking not less than 100 mADC shall be
used. The loads should have a current display, if not then an ammeter should be added in series with the
load. Refer to the schematic shown in Figure 2.
Oscilloscope: A 20-MHz or equivalent analog or digital oscilloscope with Tektronix P6138 or equivalent
oscilloscope probe. Set scope for AC coupling measurement with 20-MHz bandwidth limiting. Use
20-mV/div. vertical resolution, 5.0-µs/div. horizontal resolution for VOUT ripple voltage test. Set horizontal
cursor to measure ripple voltage.
Recommended Wire Gauge: The minimum recommended wire size is AWG #26, with the total length of
wire less than 8 feet (4 feet output, 4 feet return).
Ventilation FAN: A small fan capable of 200 LFM to 400 LFM is optional to reduce component
temperatures, but it is not a requirement in the test at room temperature
5.2
Recommended Test Setup
VOUT-1 measure
VOUT1-ripple
(TP8)
Vm1
+
+
C
+
Load-1
13V/0.15A
B
VOUT-1
A
+
Load-2
13V/0.15A
Vms1
+
VOUT-2
Voltage Source
Vsc1
36 to 72VDC
Ams1
+
A
B
C
+
+
VOUT-2 measure
Vm2
VOUT2-ripple
(TP7)
Figure 2. UCC25230EVM-754 Recommended Test Set Up
SLUU670 – November 2011
Submit Documentation Feedback
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
5
Test Setup
5.3
www.ti.com
List of Test Points
Table 2. Test Points Functions
6
TEST POINTS
NAME
TP1
Vin
Input voltage positive test point, for efficiency test
DESCRIPTION
TP2
GND
Input voltage negative test point, for efficiency test
TP3
VDD
Device VDD on primary side
TP4
VIN_G
VIN_G good, when it is good, TP4 voltage is in 4.2 V to 5.2 V
TP5
Loop+
Feedback loop test point
TP6
Loop-
Feedback loop test point
TP7
Vo2_rpl
Output-2 voltage ripple test point
TP8
Vo1_rpl
Output-1 voltage ripple test point
TP9
Vo2+
Output-2 output terminal
TP10
Vo2-
Output-2 return terminal
TP11
Vo1+
Output-1 output terminal
TP12
Vo1-
Output-1 return terminal
TP13
GND
Primary-side ground
TP14
GND
Primary-side ground
TP15
Phase
TP16
L1-2
J1
INPUT
J2
VOUT-2
Output-2 load connection terminals
Output-1 load connection terminals
J3
VOUT-1
S1
VIN_G
S2
VDD_short
Primary-side phase node
Inductor coupled coil on the secondary side
Input voltage terminals
Input voltage good manual switch
VDD short circuit current measurement switch – not installed
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
SLUU670 – November 2011
Submit Documentation Feedback
Test Procedure
www.ti.com
6
Test Procedure
Set up the EVM based on Figure 2.
CAUTION
High voltage and high temperature present when the EVM is in operation!
6.1
Line/Load Regulation and Efficiency Measurement Procedure
1. Connect the ammeter Ams1 (0 mA to 100 mA range) between DC source and J1 as shown in
Figure 2.
2. Prior to connecting the DC source, Vsc1, it is advisable to limit the source current to 0.35 A maximum.
Make sure the DC source is initially set to 0 V and connected to J1 and Ams1 as shown in Figure 2.
3. Connect voltmeter, Vms1, on to the test points, TP1 (+) and TP2 (-) as shown in Figure 2.
4. Connect Load-1 to J3 as shown in Figure 2. Set Load-1 to constant current mode to sink 0 mADC
before the input voltage on J1 is applied.
5. Connect voltmeter, Vm1 to test point TP11 (+) and TP12(-). Set Vm1 range 0 V to 13 VDC as shown in
Figure 2.
6. Connect Load-2 to J2 as shown in Figure 2. Set Load-2 to constant current mode to sink 0 mADC
before the input voltage on J1 is applied.
7. Connect voltmeter, Vm2 to test point TP9 (+) and TP10(-). Set Vm2 range 0 V to 13 VDC as shown in
Figure 2.
8. Increase the DC source voltage from 0 V to 36.0 VDC.
9. Set Load-1 to 65 mA ±0.1 mA.
10. Vary Load-2 to 0.0 mA to 65 mA.
11. Read Ams1, Vm1, and Vm2.
12. Set Load-1 to 0.0 mA.
13. Vary Load-1 to 0.0 mA to 65.0 mA
14. Read Ams1, Vm1, and Vm2.
15. Increase the DC source voltage to 72.0 V,
16. Repeat steps 9 to 14.
17. During above tests out ripple can be observed on TP8 for VOUT-1 and TP7 for VOUT-2.
6.2
Equipment Shutdown
1.
2.
3.
4.
Decrease Load-1 and Load-2 to 0 mA.
Decrease VIN from 72 V to 0 V.
Shut down VSC1.
Shut down the loads.
SLUU670 – November 2011
Submit Documentation Feedback
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
7
Performance Data and Typical Characteristic Curves
7
www.ti.com
Performance Data and Typical Characteristic Curves
Figure 3 through Figure 11 present typical performance curves for UCC25230EVM-754.
7.1
Efficiency
100
90
80
Efficiency (%)
70
60
50
40
30
20
36 V
48 V
72 V
10
0
10
20
30
40
50
60
70
Output Current (mA)
G000
Figure 3.
100
90
80
Efficiency (%)
70
60
50
40
30
20
36 V
48 V
72 V
10
0
10
20
30
40
50
60
Output Current (mA)
70
G000
Figure 4.
8
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
SLUU670 – November 2011
Submit Documentation Feedback
Performance Data and Typical Characteristic Curves
www.ti.com
7.2
Load Regulation
12.5
12
Output Voltage (V)
11.5
11
10.5
10
36 V, 48 V, 72 V
72 V
48 V
36 V
9.5
9
0
10
20
30
40
50
Output Current (mA)
60
G000
Figure 5.
12.5
12
Output Voltage (V)
11.5
11
10.5
10
36 V, 48 V, 72 V
72 V
48 V
36 V
9.5
9
0
10
20
30
40
50
Output Current (mA)
60
G000
Figure 6.
SLUU670 – November 2011
Submit Documentation Feedback
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
9
Performance Data and Typical Characteristic Curves
7.3
www.ti.com
Regulation at Corner Conditions
Table 3. UCC25230EVM-754 Regulation at Corners
VIN (V)
IO1 (mA)
IO2 (mA)
0.0
36
65.0
VO2 (V)
11.50
65.0
9.70
0.0
12.10
65.0
72
100.0
10.50
11.85
0.0
0.0
7.4
VO1 (V)
0.0
11.75
65.0
10.25
0.0
12.30
65.0
11.10
Bode Plots
Gain and Phase vs. Frequency
120.00
60.00
100.00
80.00
40.00
60.00
40.00
Gain - dB
20.00
20.00
0.00
0.00
-20.00
-40.00
-20.00
-60.00
-80.00
-40.00
-100.00
-60.00
0.1
1.0
10.0
-120.00
100.0
F - Frequency - kHz
Gain
Phase
Figure 7. Bode Plots,
Test Points Used: TP5 and TP6,
(Vin = 48V, Io1 = 50mA, Io2 = 50mA)
10
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
SLUU670 – November 2011
Submit Documentation Feedback
Performance Data and Typical Characteristic Curves
www.ti.com
7.5
Output Ripple
Figure 8. Output Ripple
(VIN = 48 V, Io1 = Io2 = 50 mA from Vo1 (TP8) or Vo2 (TP7))
7.6
Phase-Node Voltage
Figure 9. Switching-Node Waveform
(CH1 = Phase (TP15), Ch2 = Vo1 ripple, Ch3 = Vo2 ripple, VIN = 48 V, Io1 = Io2 = 50 mA)
SLUU670 – November 2011
Submit Documentation Feedback
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
11
Performance Data and Typical Characteristic Curves
7.7
www.ti.com
Turn-On Waveform
Figure 10. Enable Turn-On Waveform
(VIN = 48 V, Io1 = Io2 = 50 mA, Ch1: Vo1 (TP8), Vo2 (TP7))
7.8
Turn-Off Waveform
Figure 11. Enable Turn-Off Waveform
(Io1 = Io2 = 50 mA, Ch1: VIN (TP1, 2), Ch2: VIN_G (TP4))
12
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
SLUU670 – November 2011
Submit Documentation Feedback
EVM Assembly Drawing and PCB layout
www.ti.com
8
EVM Assembly Drawing and PCB layout
The following figures (Figure 12 through Figure 17) show the design of the UCC25230EVM-754 printed
circuit board.
• PCB dimensions: L x W = 2.2 inch x 1.4 inch,
• PCB material: FR406 or compatible, four layers and 2-oz copper on each layer.
Figure 12. UCC25230EVM-754 Top Layer Assembly Drawing (top view)
Figure 13. Bottom Assembly Drawing (bottom view)
SLUU670 – November 2011
Submit Documentation Feedback
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
13
EVM Assembly Drawing and PCB layout
www.ti.com
Figure 14. Top Copper (top View)
Figure 15. Internal Layer 1 (top view)
14
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
SLUU670 – November 2011
Submit Documentation Feedback
EVM Assembly Drawing and PCB layout
www.ti.com
Figure 16. Internal Layer 2 (top view)
Figure 17. Bottom Copper (top view)
SLUU670 – November 2011
Submit Documentation Feedback
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
15
List of Materials
9
www.ti.com
List of Materials
The EVM components list according to the schematic shown in Figure 1.
Table 4. UCC25230EVM-754 List of Materials
QTY
16
REF DES
DESCRIPTION
PART NUMBER
MFR
1
C1
Capacitor, ceramic, 100 V, X7R, 20%, 1 µF, 1206
std
std
1
C12
Capacitor, ceramic, 2000 V, X7R, 20%, 1000 pF, 1206
std
std
4
C2, C6, C9,
C11
Capacitor, ceramic, 16 V, X7R, ±10%, 1 µF, 0603
std
std
1
C3
Capacitor, ceramic, 50 V, NP0, ±10%, 1000 pF, 0603
std
std
1
C4
Capacitor, ceramic, 50 V, X7R, ±10%, 47 pF, 0603
std
std
2
C5, C15
Capacitor, ceramic, 16 V, X7R, ±10%, 0.1 µF, 0603
std
std
1
C7
Capacitor, ceramic, 50 V, NP0, ±10%, 270 pF, 0603
std
std
4
C8, C10,
C13, C14
Capacitor, ceramic, 16 V, X5R, ±10%, 4.7 µF, 0805
std
std
1
D1
Diode, switching, 200 mA, 85 V, 350 mW, SOT23
BAS16
Fairchild
1
D2
Diode, Zener, 11 V, 20 mA, 225 mW, 5%, SOT23
BZX84C11LT1G
Onsemi
1
D3
Diode, Zener, 3.9 V, 20 mA, 225 mW, 5%, SOT23
BZX84C3V9LT1G
Onsemi
3
J1, J2, J3
Terminal block, 2 pin, 6 A, 3.5 mm, 0.27 inch x 0.25 inch
OSTTE020161
OST
1
L1
Inductor, SMT, 0.35 A, 3.3 Ω, 220 µH, 0.19 inch x 0.19 inch
MA5401-AE
Coilcraft
1
R1
Resistor, chip, 1/16 W, 1%, 20.5 kΩ, 0603
std
std
1
R10
Resistor, chip, 1/16 W, 1%, 6.81 kΩ, 0603
std
std
0
R11
Resistor, chip, 1/10 W, 1%, open, 0805
std
std
1
R2
Resistor, chip, 1/8 W, 1%, 316 kΩ, 0805
std
std
1
R3
Resistor, chip, 1/16 W, 1%, 47.5 kΩ, 0603
std
std
2
R4, R5
Resistor, chip, 1/16 W, 1%, 10 kΩ, 0603
std
std
1
R6
Resistor, chip, 1/16 W, 1%, 178 kΩ, 0603
std
std
1
R7
Resistor, chip, 1/16 W, 1%, 3.65 kΩ, 0603
std
std
2
R8, R12
Resistor, chip, 1/16 W, 1%, 49.9 Ω, 0603
std
std
1
R9
Resistor, chip, 1/16 W, 1%, 0 Ω, 0603
std
std
1
S1
Switch, actuator SPDT, 0.18 inch x 0.28 inch
AYZ0102AGRLC
C&K
0
S2
Switch, actuator SPDT, open, 0.18 inch x 0.28 inch
AYZ0102AGRLC
C&K
1
U1
12-V to 100-V input, 0.25-A output switching converter, VSON
UCC25230DRM
TI
1.5-W Forward-Flyback DC-to-DC Converter for 48-V Telecom Biasing Supply
Copyright © 2011, Texas Instruments Incorporated
SLUU670 – November 2011
Submit Documentation Feedback
Evaluation Board/Kit Important Notice
Texas Instruments (TI) provides the enclosed product(s) under the following conditions:
This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION
PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. Persons handling the
product(s) must have electronics training and observe good engineering practice standards. As such, the goods being provided are
not intended to be complete in terms of required design-, marketing-, and/or manufacturing-related protective considerations,
including product safety and environmental measures typically found in end products that incorporate such semiconductor
components or circuit boards. This evaluation board/kit does not fall within the scope of the European Union directives regarding
electromagnetic compatibility, restricted substances (RoHS), recycling (WEEE), FCC, CE or UL, and therefore may not meet the
technical requirements of these directives or other related directives.
Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30
days from the date of delivery for a full refund. THE FOREGOING WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY
SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all
claims arising from the handling or use of the goods. Due to the open construction of the product, it is the user’s responsibility to
take any and all appropriate precautions with regard to electrostatic discharge.
EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive.
TI assumes no liability for applications assistance, customer product design, software performance, or infringement of
patents or services described herein.
Please read the User’s Guide and, specifically, the Warnings and Restrictions notice in the User’s Guide prior to handling the
product. This notice contains important safety information about temperatures and voltages. For additional information on TI’s
environmental and/or safety programs, please contact the TI application engineer or visit www.ti.com/esh.
No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used.
FCC Warning
This evaluation board/kit is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION, OR EVALUATION
PURPOSES ONLY and is not considered by TI to be a finished end-product fit for general consumer use. It generates, uses, and
can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15
of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this
equipment in other environments may cause interference with radio communications, in which case the user at his own expense
will be required to take whatever measures may be required to correct this interference.
EVM Warnings and Restrictions
It is important to operate this EVM within the input voltage range of 36 V to 72 V and the output voltage range of 8.5 V to 12.5 V .
Exceeding the specified input range may cause unexpected operation and/or irreversible damage to the EVM. If there are
questions concerning the input range, please contact a TI field representative prior to connecting the input power.
Applying loads outside of the specified output range may result in unintended operation and/or possible permanent damage to the
EVM. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load
specification, please contact a TI field representative.
During normal operation, some circuit components may have case temperatures greater than 60° C. The EVM is designed to
operate properly with certain components above 60° C as long as the input and output ranges are maintained. These components
include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors. These types of
devices can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near
these devices during operation, please be aware that these devices may be very warm to the touch.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2011, Texas Instruments Incorporated
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS
Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions:
The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims
arising from the handling or use of the goods.
Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from
the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO
BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH
ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES.
Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This
notice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safety
programs, please visit www.ti.com/esh or contact TI.
No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and
therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design,
software performance, or infringement of patents or services described herein.
REGULATORY COMPLIANCE INFORMATION
As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal
Communications Commission (FCC) and Industry Canada (IC) rules.
For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT,
DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer
use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing
devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency
interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will
be required to take whatever measures may be required to correct this interference.
General Statement for EVMs including a radio
User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and
power limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local
laws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate this
radio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited and
unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory
authorities, which is responsibility of user including its acceptable authorization.
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant
Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the
equipment.
FCC Interference Statement for Class A EVM devices
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Interference Statement for Class B EVM devices
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
For EVMs annotated as IC – INDUSTRY CANADA Compliant
This Class A or B digital apparatus complies with Canadian ICES-003.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
Concerning EVMs including radio transmitters
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Concerning EVMs including detachable antennas
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum
permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain
greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada.
Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de
l'utilisateur pour actionner l'équipement.
Concernant les EVMs avec appareils radio
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Concernant les EVMs avec antennes détachables
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain
maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à
l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel
d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans
cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
【Important Notice for Users of this Product in Japan】
】
This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan
If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:
1.
2.
3.
Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and
Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of
Japan,
Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this
product, or
Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with
respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note
that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.
Texas Instruments Japan Limited
(address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan
http://www.tij.co.jp
【ご使用にあたっての注】
本開発キットは技術基準適合証明を受けておりません。
本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。
1.
2.
3.
電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。
実験局の免許を取得後ご使用いただく。
技術基準適合証明を取得後ご使用いただく。
なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。
上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。
日本テキサス・インスツルメンツ株式会社
東京都新宿区西新宿6丁目24番1号
西新宿三井ビル
http://www.tij.co.jp
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
EVALUATION BOARD/KIT/MODULE (EVM)
WARNINGS, RESTRICTIONS AND DISCLAIMERS
For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished
electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in
laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks
associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end
product.
Your Sole Responsibility and Risk. You acknowledge, represent and agree that:
1.
2.
3.
4.
You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug
Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees,
affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes.
You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable
regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates,
contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical)
between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to
minimize the risk of electrical shock hazard.
You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even
if the EVM should fail to perform as described or expected.
You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.
Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the
user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and
environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact
a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the
specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or
interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the
load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures
greater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components include
but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the
EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please
be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable
in electronic measurement and diagnostics normally found in development environments should use these EVMs.
Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives
harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in
connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims
arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected.
Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such
as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices
which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate
Assurance and Indemnity Agreement.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2012, Texas Instruments Incorporated
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as “components”) are sold subject to TI’s terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TI’s terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers’ products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers’ products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TI’s goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or “enhanced plastic” are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components which meet ISO/TS16949 requirements, mainly for automotive use. Components which
have not been so designated are neither designed nor intended for automotive use; and TI will not be responsible for any failure of such
components to meet such requirements.
Products
Applications
Audio
www.ti.com/audio
Automotive and Transportation
www.ti.com/automotive
Amplifiers
amplifier.ti.com
Communications and Telecom
www.ti.com/communications
Data Converters
dataconverter.ti.com
Computers and Peripherals
www.ti.com/computers
DLP® Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
Energy and Lighting
www.ti.com/energy
Clocks and Timers
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
Space, Avionics and Defense
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
Video and Imaging
www.ti.com/video
RFID
www.ti-rfid.com
OMAP Applications Processors
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2012, Texas Instruments Incorporated