Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
date
03/30/2023
page
1 of 6
SERIES: VX78-1000R │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR
FEATURES
•
•
•
•
•
•
•
•
•
•
wide input
pin-out compatible with linear regulators
encapsulated
UL & CSA approved
high efficiency up to 96%
no-load input current as low as 0.2 mA
wide operating temp: -40°C to +85°C
supports negative output
short circuit protection on the output
designed to meet EN/BS EN 62368-1
MODEL
input
voltage1
output
voltage
output
current
output
power
ripple
& noise2
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
VX7803-1000R
24
6~36
3.3
1000
3.3
75
90
VX7805-1000R
24
12
8~36
8~27
5
-5
1000
-500
5
2.5
75
75
93
86
VX7809-1000R
24
13~36
9
1000
9
75
95
VX7812-1000R
24
12
16~36
8~20
12
-12
1000
-300
12
3.6
75
75
96
89
VX7815-1000R
24
12
20~36
8~18
15
-15
1000
-300
15
4.5
75
75
96
89
Note:
1. For input voltage exceeding 30 VDC, an input capacitor of 22uF/50V is required
2. 20MHz bandwidth, nominal input, 20%-100% load. With light loads at or below 20%, ripple and noise for 3/3V/5V output parts increases to 100mVp-p and for
9V/12V/15V output parts to 2%Vo max.
PART NUMBER KEY
VX78XX-1000R
Base Number
Output Voltage
cui.com
Output Current
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VX78-1000R │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR
date 03/30/2023 │ page 2 of 6
INPUT
parameter
conditions/description
filter
capacitor filter
no-load input current
positive outputs
min
typ
max
units
0.1
1
mA
typ
max
units
680
330
μF
μF
OUTPUT
parameter
conditions/description
maximum capacitive load
for positive output applications
for negative output applications
min
voltage accuracy
at full load, input voltage range
3.3 Vdc output model
all other models
±2
±2
±4
±3
%
%
line regulation
at full load, input voltage range
±0.2
±0.4
%
load regulation
at nominal input, 10~100% load
±0.4
±0.6
%
switching frequency
at nominal input voltage, full load
3.3/5 Vdc output models
all other models
520
680
620
780
kHz
kHz
transient recovery time
at nominal input voltage, 25% load step change
0.1
1
ms
transient response deviation
at nominal input voltage, 25% load step change
50
temperature coefficient
Operating ambient temperature -40°C to +85°C
420
580
300
mV
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, auto recovery
min
typ
max
units
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
safety approvals
certified to 60950: UL
designed to meet 62368-1: EN, BS EN
conducted emissions
CISPR22/EN55022, class B (external circuit required, see Figure 4-b)
radiated emissions
CISPR22/EN55022, class B (external circuit required, see Figure 4-b)
ESD
IEC/EN61000-4-2, contact ± 4kV, criteria B
radiated immunity
IEC/EN61000-4-3, 10V/m, criteria A
EFT/burst
IEC/EN61000-4-4, ± 1kV, criteria B (external circuit required, see Figure 4-a)
surge
IEC/EN61000-4-5, line-line ± 1kV, criteria B (external circuit required, see Figure 4-a)
conducted immunity
IEC/EN61000-4-6, 3 Vr.m.s, criteria A
MTBF
as per MIL-HDBK-217F, 25°C
RoHS
yes
2,000,000
cui.com
hours
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VX78-1000R │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR
date 03/30/2023 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
85
°C
-55
125
°C
5
95
%
max
units
storage temperature
storage humidity
non-condensing
typ
MECHANICAL
parameter
conditions/description
dimensions
11.50 x 9.00 x 17.50 [0.453 x 0.354 x 0.689 inch]
min
case material
black flame-retardant heat-proof plastic (UL94V-0)
weight
typ
mm
3.8
MECHANICAL DRAWING
units: mm [inch]
tolerance: ±0.25[±0.010]
pin diameter tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
+OUTPUT
-OUTPUT
1
+VIN
+VIN
2
GND
-VOUT
3
+VOUT
GND
cui.com
g
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: VX78-1000R │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR
DERATING CURVE
EFFICIENCY CURVES
cui.com
|
PCB Footprint
date 03/30/2023 │ page 4 of 6
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VX78-1000R │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR
date 03/30/2023 │ page 5 of 6
TYPICAL APPLICATION CIRCUIT
Figure 1
Positive output application circuit
Figure 2
Negative output application circuit
Figure 3
Table 1
External Capacitor Table
Model Number
Note:
C1, C3
C2, C4
(ceramic capacitor) (ceramic capacitor)
VX7803-1000R
10 μF/50 V
22 μF/10 V
VX7805-1000R
10 μF/50 V
22 μF/10 V
VX7809-1000R
10 μF/50 V
22 μF/16 V
VX7812-1000R
10 μF/50 V
22 μF/25 V
VX7815-1000R
10 μF/50 V
22 μF/25 V
1. C1 & C2 (C3 & C4) are required and should be connected as close to the module pins as possible.
2. Refer to Table 1 for C1 and C2 (C3 and C4) capacitor values. For certain applications, increased values for C2 and C4 and/or tantalum or low ESR electrolytic capacitors
may also be used instead;
3. When using configurations as shown in figure 3, we recommended to add an inductor (LDM) with a value of up to 10μH which helps reducing mutual interference;
4. Converter cannot be used for hot swap and with output in parallel.
EMC RECOMMENDED CIRCUIT
Figure 4
Table 2
Recommended external circuit components
Note:
1. Part ① in Fig. 4 shows EMS compliance filter and part ➁ filter for EMI compliance;
depending on requirement both filters ① and ➁ can be used in series as shown.
cui.com
FUSE
choose according to actual input current
MOV
S20K30
LDM1
82 µH
C0
680 µF/50 V
C1, C2
see Table 1
C5
4.7 µF/50 V
LDM2
12 µH
Additional Resources:
Product Page
|
3D Model
|
PCB Footprint
CUI Inc │ SERIES: VX78-1000R │ DESCRIPTION: NON-ISOLATED DC SWITCHING REGULATOR
date 03/30/2023 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
03/09/2020
1.01
safeties updated
02/03/2021
1.02
derating curve, efficiency curves and circuit figures updated
09/21/2021
1.03
safeties updated
12/20/2022
application circuits updated
03/30/2023
1.04
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
很抱歉,暂时无法提供与“VX7809-1000R”相匹配的价格&库存,您可以联系我们找货
免费人工找货