0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PS12800

PS12800

  • 厂商:

    ETC2

  • 封装:

  • 描述:

    PS12800 - Current Loop Interface Converter - List of Unclassifed Manufacturers

  • 数据手册
  • 价格&库存
PS12800 数据手册
ORDERING MIC-24/CL/A/* Active Unit, Interface converter for current loop * Specify 60 for optional 60 mA, factory set (Default is 20 mA) MIC-24/CL/P/+ Passive Unit, Interface converter for current loop + Specify F for female 25-pin connector Specify M for male 25-pin connector P/S-AC/12/800 90 to 264 VAC external power supply for MIC-24/CL/A MIC-24/CL Current Loop Interface Converter Specifications are subject to change without prior notice. 253-100-04/00  2000 RAD Data Communications Ltd. Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com FEATURES APPLICATIONS DESCRIPTION • MIC-24/CL enables communication between equipment with current loop interface and devices with RS-232 / V.24 interface. MIC-24/CL operates bidirectionally, full or half-duplex, converting the RS-232 / V.24 voltage levels to loop closure or loop opening. active and passive current loop transmissions: • • • • • • • • • • Conversion of RS-232/V.24 to current loop, bidirectional Distances up to 6.5 km / 4 miles Data rates up to 19.2 bps Full or half duplex 20 mA current loop, 60 mA optional Active or passive units LEDs indicating RD, TD activity (active only) DCE/DTE switch Miniature, lightweight Easy to install • MIC-24CL is available in two models, for MIC -24/CL/A (active) allows both the transmitter and the receiver to supply the current loop source or only the transmitter to supply the source (strap-selectable, see Figures 1,2. The active unit operates with 20 mA (60 mA optional ordering) and requires a standard external power supply of 12V. LED indicators, POWER, TD and RD, monitor the data flow for transmit and receive signals. MIC -24/CL/P (passive) always accepts the supplied loop current from both transmit and receive lines (see Figure 3). The passive unit operates with 20 or 60 mA, without requiring an external power source. Its power is derived from the RS-232 / V.24 data and control source signals. • Both models feature a DCE/DTE switch to simplify installation and eliminate the need for cross cables. Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com SPECIFICATIONS • Data Transmission • Range Asynchronous, full or half duplex Up to 6.5 km / 4 miles RS-232/V.24 Active Unit: Current loop 20 mA 60 mA optional Passive Unit: Current loop 20 or 60 mA Up to 19.2 kbps One miniature D-25 pin male connector (the passive model also includes an optional female connector, see Ordering). 4-screw terminal block DC power connector (active unit only) Active unit: POWER, TD (transmit) RD (receive) Passive unit: no AC power supply required, uses ultra-low power derived from the RS-232/V.24 data and control signals Active unit: requires standard external power supply of 12 ± 2V at 150 mA. Alternatively, power can be supplied to pin 9 of the DB-25 connector, without external power supply. • Physical Length: 110 mm / 4.3 in Width: 55 mm / 2.1 in Height: 22 mm / 0.9 in Weight: 75 g / 2.6 oz Temperature: 0-50oC / 32-122oF Humidity: Up to 90%, non-condensing Declaration of Conformity Mfr. Name: Mfr. Address: RAD Data Communications Ltd. 12 Hanechoshet St. Tel Aviv 69710 Israel • Environment • Interface declares that the products: Product Name: MIC-24/CL/A, MIC-24/CL/P Conform to the following standard(s) or other normative document(s): EMC: EN 55022 (1994): Limits and methods of measurement of radio disturbance characteristics of information technology equipment. EN 50082-1 (1992): Electromagnetic compatibility - Generic immunity standards for residential, commercial and light industry. Supplementary Information: The product herewith complies with the requirements of the EMC Directive 89/336/EEC and the Low Voltage Directive 73/23/EEC. The product was tested in a typical configuration. Tel Aviv, January 30th 1996 • Data Rates • Connectors • LEDs • Power Haim Karshen VP Quality European Contact: RAD Data Communications GmbH, Lyoner Strasse 14, 60528 Frankfurt am Main, Germany Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com INSTALLATION Caution. This is a delicate instrument. Be careful when setting jumpers or performing any actions within the product so that you do not break or shake any components. 6. Plug the unit directly into the 25-pin connector of the RS-232/V.24 equipment and fasten with the screws. Note: For the MIC-24/CL/A unit, plug in the power connector and check that the POWER LED is on. MIC-24/CL is easy to configure and install. Review Table 1 and Figure 4 for the factory settings as the unit may already be strapped to suit your application. If not, follow these steps: 1. Open the unit by pressing the marked places on the sides, starting at the cable end. Table 1. Strap Selection Strap DCE/DTE Function Factory Setting 3. Figure 4. Strapping Diagram In the MIC-24/CL/A (active unit), set the double RECEIVER strap to the position for the Receive circuitry to be active or passive. When RECEIVER is set to ACTIVE, “Rxa” is the positive lead and “Rxb” is the negative lead. When RECEIVER is set to PASSIVE, the polarity is reversed: “RXa” is the negative lead and “RXb” is the positive lead. Connect the 4-wire line to the screw terminal block: transmit pair to “TX” and receive pair to “RX”, maintaining polarity. Note: Remote “TX” should be connected to local “RX” and vice versa. 5. Close the unit by pressing the two halves of the cover together. Designates if unit is DCE configured as a DCE or DTE Selects the Receive ACTIVE circuitry to be either active (supplying current) or passive (sinking current). ACTIVE/ PASSIVE (on the active unit only) 2. Set the DCE/DTE switch to the required position. When set to DCE, the unit is configured as a DCE for connection to a computer or terminal. When set to DTE, it operates as a DTE. 4. Order from: Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com
PS12800 价格&库存

很抱歉,暂时无法提供与“PS12800”相匹配的价格&库存,您可以联系我们找货

免费人工找货