HPP805A031

HPP805A031

  • 厂商:

    HUMIREL(泰科)

  • 封装:

    -

  • 描述:

    SENSOR HUMIDITY 5V ANLG 3% MOD

  • 数据手册
  • 价格&库存
HPP805A031 数据手册
HM1500LF – Relative Humidity Module • Small size product • Product free from Lead, Cr(6+), Cd and Hg • Humidity calibrated within +/-2% @55%RH • Typical 1 to 3.6 Volt DC output for 0 to 100% RH at 5Vdc supply • Ratiometric to voltage supply from 4.75Vdc to 5Vdc • Patented solid polymer structure DESCRIPTION Based on the rugged HS1101LF capacitive humidity sensor, HM1500LF is a dedicated humidity transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made possible with the module’s linear voltage output. FEATURES APPLICATIONS • Full interchangeability • High reliability and long term stability • •• Not affected by water immersion • Suitable for 3 to 10 Vdc supply voltage • •• •• Industrial Process control … Very low temperature dependence Humidity Sensor Specific features Instantaneous de-saturation after long periods in saturation phase Fast response time Part could be washed with distilled water (1) Soldering temperature profiles available on request / contact us at humidity.application@meas-spec.com PERFORMANCE SPECS MAXIMUM RATINGS Ratings Storage Temperature Storage Humidity Supply Voltage (Peak) Humidity Operating Range Temperature Operating Range HM1500LF HPC062_F Symbol Tstg RHstg Value -30 to 70 0 to 100 Unit °C % RH Vs RH Ta 10 0 to 100 -40 to 60 Vdc % RH °C www.meas-spec.com 1/5 October 2012 HM1500LF – Relative Humidity Module ELECTRICAL CHARACTERISTICS (Ta=23°C, Vs=5Vdc +/-5%, R L>1MΩ unless otherwise stated) Humidity Characteristics Humidity Measuring Range Relative Humidity Accuracy (10 to 95% RH) Supply Voltage (regulated at 5Vdc*) Nominal Output @55%RH (at 5Vdc) Current consumption Temperature Coefficient (10 to 50°C) Average Sensitivity from 33% to 75%RH Sink Current Capability (RL=33kΩ) Humidity Hysteresis Time Constant (at 63% of signal, static) 33% to 75%RH Warm up time (electronic) Humidity resolution Output Impedance Symbol RH RH Vs Vout Ic Tcc ∆Vout/∆RH Is Min 0 2.42 Typ +/-3 5 2.48 1.4 - 0.05 +26 Max 100 +/-5 2.54 2 -0 .1 150 +/-1 10 τ tw 150 0.4 70 Z Unit %RH %RH Vdc V mA %RH/°C mV/%RH µA %RH s ms %RH Ω *Maximum power supply ramp up time to Vcc should be less than 4ms. TYPICAL PERFORMANCE CURVES HUMIDITY SENSOR • Measurement conditions HM1500LF is specified for accurate measurements within 10 to 95% RH. Excursion out of this range (95% RH, including condensation) does not affect the reliability of HM1500LF characteristics. Dedicated HM15XX products are available for extreme RH conditions (as HM1520 for low dewpoints). Consult MEASFRANCE for further information. • Modeled Signal Output RH (%) 10 15 20 25 30 35 40 45 50 HM1500LF HPC062_F www.meas-spec.com 2/5 Vout (mV) 1325 1465 1600 1735 1860 1990 2110 2235 2360 RH (%) 55 60 65 70 75 80 85 90 95 Vout (mV) 2480 2605 2730 2860 2990 3125 3260 3405 3555 October 2012 HM1500LF – Relative Humidity Module LINEAR EQUATIONS:  Vout = 25.68RH + 1079  RH = 0.03892 Vout - 42.017 (With Vout in mV and RH in %) POLYNOMIAL EQUATIONS: -4 3 -1 2  Vout = 9E RH - 1.3E RH + 30.815 RH + 1030 -9 3 -5 2 -3 +1  RH = -1,91E Vout + 1,33E Vout + 9,56E Vout - 2,16E (With Vout in mV and RH in %) • Error Budget at 23°C TEMPERATURE COMPENSATION: RH compensaed = RH actualatT + (T − 23) × 0.05 (With T: Temperature in °C and RH: Relative Humidit y in %) QUALIFICATION PROCESS RESISTANCE TO PHYSICAL AND CHEMICAL STRESSES • • • HM1500LF has passed through qualification processes of MEAS-FRANCE including vibration, shock, storage, high temperature and humidity, ESD. Additional tests under harsh chemical conditions demonstrate good operation in presence of salt atmosphere, SO2 (0.5%, H2S (0.5%), 03, NOx, NO, CO, CO2, Softener, Soap, Toluene, acids (H2SO4, HNO3, HCI), HMDS, Insecticide, Cigarette smoke, this is not an exhaustive list. HM1500LF is not light sensitive. SPECIFIC PRECAUTIONS • • HM1500LF is protected against reversed polarity. If you wish to use HM1500LF in a chemical atmosphere not listed above, consult us. HM1500LF HPC062_F www.meas-spec.com 3/5 October 2012 HM1500LF – Relative Humidity Module PACKAGE OUTLINE Dim Min (mm) Max (mm) A 9.75 10.25 B 4.00 4.50 C 53 55 D 10.9 11.4 E* 200 250 * Specific lenght available on request Wire Color Function W1 White Ground W2 Blue Supply Voltage W3 Yellow Humidity Output Voltage ORDERING INFORMATION HPP805A031 (MULTIPLE PACKAGE QUANTITY OF 10 PIECES) HM1500LF – HUMIDITY ANALOG VOLTAGE OUTPUT Sample kit of HM1500LF is available through MEASUREMENT SPECIALTIES web site: http://www.meas-spec.com/humidity-sensors.aspx Customer Service contact details Measurement Specialties, Inc - MEAS France Impasse Jeanne Benozzi CS 83 163 31027 Toulouse Cedex 3 FRANCE Tél: +33 (0)5 820 822 02 Fax: +33(0)5 820 821 51 Sales: humidity.sales@meas-spec.com HM1500LF HPC062_F www.meas-spec.com 4/5 October 2012 HM1500LF – Relative Humidity Module Revision C D E F Comments Power supply ramp up time specification added HPP Number updated, RoHS logo added Standardized datasheet format and Current consumption lowering updated New MEAS template, MEAS-France contact details updated Who C.EISMANN D. LE GALL Date September 06 September 07 D. LE GALL April 08 D. LE GALL-ZIRILLI October 12 The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. HM1500LF HPC062_F www.meas-spec.com 5/5 October 2012
HPP805A031 价格&库存

很抱歉,暂时无法提供与“HPP805A031”相匹配的价格&库存,您可以联系我们找货

免费人工找货