Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 50 – 100 VDC
(Commercial Grade)
Overview
KEMET’s epoxy molded axial through-hole ceramic
capacitors in X7R dielectric feature a 125°C maximum
operating temperature. The Electronics Industries
Alliance (EIA) characterizes X7R dielectric as a Class
II “temperature stable” material. Components of this
classification are fixed, ceramic dielectric capacitors suited
for bypass and decoupling applications or for frequency
discriminating circuits where Q and stability of capacitance
characteristics are not critical. X7R exhibits a predictable
change in capacitance with respect to time and voltage and
boasts a minimal change in capacitance with reference to
ambient temperature. Capacitance change is limited to ±15%
from −55°C to +125°C. These devices meet the flame test
requirements outlined in UL Standard 94 V–0.
Benefits
Applications
• Axial through-hole form factor
• Molded case
• −55°C to +125°C operating temperature range
• X7R temperature stable dielectric
• DC voltage ratings of 50 V and 100 V
• Capacitance offerings ranging from 10 pF to 3.3 μF
• Available capacitance tolerances of ±10% and ±20%
• Non-polar device, minimizing installation concerns
• SnPb-plated lead finish (60/40)
• Encapsulation meets flammability standard UL 94 V–0
Typical applications include decoupling, bypass, filtering and
transient voltage suppression.
Ordering Information
C
114
Ceramic
Style
/Size
114
124
192
202
222
1
2
C
472
Specification/ Capacitance
Series
Code (pF)
C=
Standard
Two
significant
digits and
number of
zeros
M
1
R
5
C
A
7200
Capacitance
Tolerance1
Rated
Voltage
(VDC)
Dielectric
Design
Lead Finish2
Failure
Rate
Packaging/
Grade
(C-Spec)
R=
X7R
5=
Multilayer
C=
SnPb (60/40)
A=
N/A
K = ±10%
M = ±20%
5 = 50
1 = 100
Blank = Bulk
7200 = 12" Reel
7293 = Ammo
Pack
Additional capacitance tolerance offerings may be available. Contact KEMET for details.
Lead materials:
Standard: 60% tin (Sn)/40% lead (Pb) finish with 100% copper core (“C” designation).
Alternative lead materials and finishes may be available. Contact KEMET for details.
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
1
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Dimensions – Inches (Millimeters)
1.50 Minimum
(38.10)
L
1.50 Minimum
(38.10)
D
C
Series
C1XX
C2XX
Style/Size
L
Length Maximum
D
Diameter Maximum
LD
Lead Diameter
114
124
192
202
222
0.160±0.010 (4.06±0.25)
0.250±0.010 (6.35±0.25)
0.390±0.010 (9.91±0.25)
0.500±0.020 (12.70±0.51)
0.690±0.030 (17.53±0.76)
0.090±0.010 (2.29±0.25)
0.090±0.010 (2.29±0.25)
0.140±0.010 (3.56±0.25)
0.250±0.015 (6.35±0.38)
0.350±0.020 (8.89±0.51)
0.020+0.0/−0.003
(0.51+0.0/−0.08)
0.025+0.004/−0.001
(0.64+0.10/−0.025)
LL
Lead Length
Minimum
1.50 (38.10)
Application Notes
These devices are not recommended for use in overmold applications and/or processes.
Qualification/Certification
Commercial Grade products are subject to internal qualification. Details regarding test methods and conditions are referenced in Table 2, Performance & Reliability.
Environmental Compliance
These devices do not meet RoHS criteria due to the concentration of Pb containment in the lead finish.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
2
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Electrical Parameters/Characteristics
Item
Parameters/Characteristics
Operating Temperature Range
−55°C to +125°C
Capacitance Change with Reference to
+25°C and 0 VDC Applied (TCC)
±15%
Aging Rate (Maximum % Cap Loss/Decade Hour)
3.0%
Dielectric Withstanding Voltage
Dissipation Factor (DF) Maximum Limit at 25ºC
Insulation Resistance (IR) Limit at 25°C
250% of rated voltage
(5±1 seconds and charge/discharge not exceeding 50 mA)
3.5%(25 V) and 2.5%(50 V to 250 V)
1,000 megohm microfarads or 100 GΩ
(Rated voltage applied for 120±5 seconds at 25°C)
Regarding aging rate: Capacitance measurements (including tolerance) are indexed to a referee time of 1,000 hours.
To obtain IR limit, divide MΩ-µF value by the capacitance and compare to GΩ limit. Select the lower of the two limits.
Capacitance and dissipation factor (DF) measured under the following conditions:
1 kHz ±50 Hz and 1.0 ±0.2 Vrms if capacitance ≤ 10 µF
120 Hz ±10 Hz and 0.5 ±0.1 Vrms if capacitance > 10 µF
Note: When measuring capacitance it is important to ensure the set voltage level is held constant. The HP4284 and Agilent E4980 have a feature known
as Automatic Level Control (ALC). The ALC feature should be switched to "ON."
Post Environmental Limits
High Temperature Life, Biased Humidity, Moisture Resistance
Dielectric
Rated DC Voltage
Capacitance Value
> 25
X7R
16/25
< 16
DF (%)
Capacitance Shift
3.0
All
5.0
±20%
7.5
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
3
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Table 1A – C114 Style/Size (0.090" Diameter x 0.160" L), Capacitance Range Waterfall
C114 Style/Size (0.090" Diameter x 0.160" L)
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
Capacitance
Tolerance
Capacitance
10pF
12pF
15pF
18pF
22pF
27pF
33pF
39pF
47pF
56pF
68pF
82pF
100pF
120pF
150pF
180pF
220pF
270pF
330pF
390pF
470pF
560pF
680pF
820pF
1000pF
1200pF
1500pF
1800pF
2200pF
2700pF
3300pF
3900pF
4700pF
5600pF
6800pF
8200pF
0.01µF
Capacitance Code (Available Capacitance)
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
562
682
822
103
100
120
150
180
220
270
330
390
470
560
680
820
101
121
151
181
221
271
331
391
471
561
681
821
102
122
152
182
222
272
332
392
472
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
K = ±10%
M = ±20%
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
4
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Table 1B – C124 Style/Size (0.090" Diameter x 0.250" L), Capacitance Range Waterfall
C124 Style/Size (0.090" Diameter x 0.250" L)
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
Capacitance
5600pF
6800pF
8200pF
0.01µF
0.012µF
0.015µF
0.018µF
0.022µF
0.027µF
0.033µF
0.039µF
0.047µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
562
682
822
103
123
153
183
223
273
333
393
473
562
682
822
103
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
K = ±10%
M = ±20%
Table 1C – C192 Style/Size (0.140" Diameter x 0.390" L), Capacitance Range Waterfall
C192 Style/Size (0.140" Diameter x 0.390" L)
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
Capacitance
0.012µF
0.015µF
0.018µF
0.022µF
0.027µF
0.033µF
0.039µF
0.047µF
0.056µF
0.068µF
0.082µF
0.1µF
0.12µF
0.15µF
0.18µF
0.22µF
0.27µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
123
153
183
223
273
333
393
473
563
683
823
104
124
154
184
224
274
123
153
183
223
273
333
393
473
563
683
823
104
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
K = ±10%
M = ±20%
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
5
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Table 1D – C202 Style/Size (0.250" Diameter x 0.500" L), Capacitance Range Waterfall
C202 Style/Size (0.250" Diameter x 0.500" L)
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
Capacitance
0.056µF
0.068µF
0.082µF
0.1µF
0.12µF
0.15µF
0.18µF
0.22µF
0.27µF
0.33µF
0.47µF
0.68µF
1.0µF
Capacitance
Tolerance
Capacitance Code (Available Capacitance)
563
683
823
104
124
154
184
224
274
334
474
684
105
563
683
823
104
124
154
184
224
274
334
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
K = ±10%
M = ±20%
Table 1E – C222 Style/Size (0.350" Diameter x 0.690" L), Capacitance Range Waterfall
C222 Style/Size (0.350" Diameter x 0.690" L)
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
Capacitance
Capacitance
Tolerance
0.47µF
0.68µF
1.0µF
2.2µF
3.3µF
K = ±10%
M = ±20%
Capacitance Code (Available Capacitance)
474
684
105
225
335
474
684
105
Rated Voltage (VDC)
50
100
200
Voltage Code
5
1
2
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
6
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Soldering Process
Recommended Soldering Technique:
• Solder Wave
• Hand Soldering (Manual)
Recommended Soldering Profile:
• Optimum Wave Solder Profile
Solder Wave Peak
Temperature 260ºC
Entrance to Solder Wave
Degrees – Cº
Flux Zone
250
225
200
175
150
125
100
75
50
25
Exit from Solder Wave
(Time in Wave – 2 to 4 Seconds)
Preheat Zone
Hot Air Debridging
Exit from
Solder
Machine
80ºC
to 120ºC
Entrance
to Solder
Machine
Free
Air
Cool
Bottom Side
Temperature
Range
Entrance to
In-Line Cleaner
Exit from
In-Line Cleaner
(time in cleaner
may be less)
Immersion in
Cleaning
Vapor
150ºC
Maximum
Top Side
Nominal
0
1
2
3
Time (Minutes)
4
5
6
• Hand Soldering (Manual)
Manual Solder Profile with Pre-heating
Soldering
Gradual Cooling
Gradual Preheat
60 – 120 Seconds
Recommend 2.5ºC/second
Maximum 3 seconds
Delta T < = 120ºC
KEMET recommends following the guidelines and techniques outlined in technical bulletins F2103 and F9207.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
7
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Table 2 – Performance & Reliability: Test Methods and Conditions
Stress
Reference
Test or Inspection Method
Magnification 50 X. Conditions:
Solderability
J–STD–002
a) Method B, 4 hours at 155°C, dry heat at 235°C
b) Method B at 215°C category 3
c) Method D, category 3 at 260°C
Temperature Cycling
JESD22 Method JA–104
Biased Humidity
MIL–STD–202 Method
103
Moisture Resistance
Thermal Shock
High Temperature Life
Storage Life
Vibration
Resistance to Soldering
Heat
Terminal Strength
Mechanical Shock
Resistance to Solvents
MIL–STD–202 Method
106
MIL–STD–202 Method
107
MIL–STD–202 Method
108/EIA–198
MIL–STD–202 Method
108
MIL–STD–202 Method
204
MIL–STD–202 Method
210
MIL–STD–202 Method
211
MIL–STD–202 Method
213
MIL–STD–202 Method
215
1,000 cycles (−55°C to +125°C), Measurement at 24 hours. +/−2 hours after test conclusion.
Load Humidity: 1,000 hours 85°C/85% RH and Rated Voltage. Add 100 K ohm resistor.
Measurement at 24 hours. +/−2 hours after test conclusion.
Low Volt Humidity: 1,000 hours 85°C/85% RH and 1.5 V. Add 100 K ohm resistor.
Measurement at 24 hours. +/−2 hours after test conclusion.
t = 24 hours/cycle. Steps 7a and 7b not required. Unpowered.
Measurement at 24 hours. +/−2 hours after test conclusion.
−55°C/+125°C. Note: Number of cycles required – 300. Maximum transfer time – 20
seconds. Dwell time – 15 minutes. Air – Air.
1,000 hours at 125°C (85°C for X5R, Z5U and Y5V) with 2 X rated voltage applied.
150°C, 0 VDC, for 1,000 hours.
5 g for 20 minutes, 12 cycles each of 3 orientations. Note: Use 8"X5" PCB .031" thick 7
secure points on one long side and 2 secure points at corners of opposite sides. Parts
mounted within 2" from any secure point. Test from 10–2,000 Hz.
Condition B. No pre-heat of samples. Note: single wave solder - procedure 2.
Conditions A (2.3kg or 5 lbs)
Figure 1 of Method 213, Condition F.
Add aqueous wash chemical, OKEM Clean or equivalent.
Storage & Handling
Ceramic chip capacitors should be stored in normal working environments. While the chips themselves are quite robust in
other environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres,
and long term storage. In addition, packaging materials will be degraded by high temperature-reels may soften or warp, and
tape peel force may increase. KEMET recommends that maximum storage temperature not exceed 40ºC, and maximum
storage humidity not exceed 70% relative humidity. Temperature fluctuations should be minimized to avoid condensation on
the parts, and atmospheres should be free of chlorine and sulfur bearing compounds. For optimized solderability, chip stock
should be used promptly, preferably within 1.5 years of receipt.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
8
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Packaging Details
Lead Spacing
Component Pitch (P1)
0.100 (2.54)
5.08
0.200 (5.08)
3.81
0.400 (10.16)
7.62
0.170 (4.32)
0.220 (5.59)
0.275 (6.98)
0.300 (7.62)
0.375 (9.52)
0.475 (12.06)
0.575 (14.60)
0.675 (17.14)
Packaging Quantities
Ammo Pack
Quantity
Maximum
Reel Quantity
Maximum
(12" Reel)
Style/
Size
Standard Bulk
Quantity
114
200/Box
5000
124
200/Box
5000
192
100/Box
202
25/Box
500
222
10/Tray
300
N/A
3000
Marking
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016
9
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
Tape & Reel Packaging Information
KEMET offers standard reeling of molded and conformally
coated axial leaded ceramic capacitors for automatic insertion
or lead forming machines in accordance with EIA standard
296. KEMET’s internal specifi cation four-digit suffi x, 7200, is
placed at the end of the part number to designate tape and reel
packaging, e.g., C410C104Z5U5CA7200.
Paper (50 lb.) test minimum is inserted between the layers
of capacitors wound on reels for component pitch ≤ 0.400".
Capacitor lead length may extend only a maximum of .0625"
(1.59 mm) beyond the tapes’ edges. Capacitors are centered in
a row between the two tapes and will deviate only ± 0.031" (0.79
mm) from the row center. A minimum of 36" (91.5 cm) leader
tape is provided at each fi nished length of taped components.
Universal splicing clips are used to connect the tape.
Table 3 – Ceramic Axial Tape and Reel Dimensions
Metric will govern
Dimensions — Millimeters (Inches)
Axial Capacitor
Body Diameter
0.0 to 5.0
(0.0 to 0.197)
A
±0.5 (0.020)
B
±1.5 (0.059)*
5.0 (0.197)
52.4 (2.062)
Symbol Reference Table
A
B
Component Pitch
Inside Tape Spacing
* Inside tape spacing dimension (B) is determined by the body diameter of the capacitor.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016 10
Axial Through-Hole Multilayer Ceramic Capacitors
Axial, Molded, X7R Dielectric, 100 – 200 VDC (Commercial Grade)
KEMET Electronic Corporation Sales Offices
For a complete list of our global sales offi ces, please visit www.kemet.com/sales.
Disclaimer
All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for
checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such
applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use.
The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any
technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no
obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component
failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards
(such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other
measures may not be required.
KEMET is a registered trademark of KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 • 864-963-6300 • www.kemet.com
C1046_X7R_AXIAL_MOLDED • 9/12/2016 11