0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SDR-120_10

SDR-120_10

  • 厂商:

    MEANWELL(明纬)

  • 封装:

  • 描述:

    SDR-120_10 - 120W Single Output Industrial DIN RAIL with PFC Function - Mean Well Enterprises Co., L...

  • 数据手册
  • 价格&库存
SDR-120_10 数据手册
120W Single Output Industrial DIN RAIL with PFC Function Features : SDR-120 series High efficiency 91% and low power dissipation 150% peak load capability Built-in active PFC function, PF>0.93 Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508 (industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level Built-in DC OK relay contact 100% full load burn-in test 3 years warranty SE PQ M IF 47 GL SDR-120-48 48V 2.5A 0 ~ 2.5A 120W 3.75A 120mVp-p 48 ~ 55V 1.0% 0.5% 1.0% SPECIFICATION MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER PEAK CURRENT PEAK POWER Note.6 OUTPUT VOLTAGE ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE SDR-120-12 12V 10A 0 ~ 10A 120W 15A 180W (3 sec.) 100mVp-p 24 ~ 28V 1.0% 0.5% 1.0% 3000ms, 60ms/115VAC at full load 20ms/115VAC at full load 124 ~ 370VDC 0.96/115VAC at full load 91% 0.7A/230VAC 70A/230VAC 90.5% SDR-120-24 24V 5A 0 ~ 5A 120W 7.5A RIPPLE & NOISE (max.) Note.2 100mVp-p 12 ~ 14V VOLTAGE TOLERANCE Note.3 1.0% 0.5% 1.0% 1500ms, 60ms/230VAC 20ms/230VAC Note.7 88 ~ 264VAC 47 ~ 63Hz 0.93/230VAC 89% 1.4A/115VAC 35A/115VAC 150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down o/p voltage after 3 seconds 14 ~ 17V 29 ~ 33V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW : detect on heatsink of power switch) 56 ~ 65V Protection type : Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION DC OK REALY CONTACT RATINGS (max.) 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load -25 ~ +70 (Refer to output load derating curve) WORKING TEMP. 20 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC / 70% RH I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS NOTE Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, SEMI F47, GL approved 289.9Khrs min. MIL-HDBK-217F (25 40*125.2*113.5mm (W*H*D) 0.67Kg; 20pcs/14.4Kg/1.16CUFT ) DIMENSION PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. 3 seconds max., please refer to peak loading curves. 7. Derating may be needed under low input voltage. Please check the derating curve for more details. File Name:SDR-120-SPEC 2010-12-07 120W Single Output Industrial DIN RAIL with PFC Function Mechanical Specification SDR-120 series Case No.992A Unit:mm 125.2 TB2 TB1 +V ADJ. DC OK 1 2 3 1 2 3 4 40 113.5 DC OK + Terminal Pin No. Assignment (TB1) Pin No. 1 2 3 Assignment FG AC/N AC/L 35 Terminal Pin No. Assignment (TB2) ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 Pin No. 1,2 3 4 Assignment Relay Contact DC OUTPUT -V DC OUTPUT+V Block Diagram DC OK I/P EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER O.C.P. +V -V U.V.P. FG PFC CONTROL O.L.P. PWM & PFC CONTROL DETECTION CIRCUIT O.V.P. DC OK Relay Contact Contact Close Contact Open PSU turns on / DC OK. PSU turns off / DC Fail. Contact Ratings (max.) 30V/1A resistive load. File Name:SDR-120-SPEC 2010-12-07 120W Single Output Industrial DIN RAIL with PFC Function Peak Loading (1) 1 80W (2) 180W SDR-120 series 120W 100 sec. 3 sec. 60W 15 sec. 3 sec. Derating Curve Output derating VS input voltage 150 Others For 3 sec. (typ.) 100 90 125 12V Others 80 70 100 LOAD (%) LOAD (%) 70 (VERTICAL) 75 Continuous 60 50 40 12V 60 -25 0 10 20 30 40 50 55 60 88 100 110 135 155 230 264 AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz File Name:SDR-120-SPEC 2010-12-07
SDR-120_10 价格&库存

很抱歉,暂时无法提供与“SDR-120_10”相匹配的价格&库存,您可以联系我们找货

免费人工找货