0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NTH0509MC-R

NTH0509MC-R

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    -

  • 描述:

    CONVDC/DCSM2W9VIN5VDUAL1KV

  • 数据手册
  • 价格&库存
NTH0509MC-R 数据手册
NTH Series www.murata.com Isolated 2W Dual Output SM DC-DC Converters V V mA mA % pF kHrs Recommended Alternative SELECTION GUIDE NTH0505MC NTH1205MC NTH1209MC NTH1215MC 5 12 12 12 ±5 ±5 ±9 ±15 ±200 ±200 ±111 ±67 500 208 201 198 80 80 83 84 27 35 57 63 2175 675 472 204 NMH0505SC Contact Murata Contact Murata NMH1215SC NTH0509MC NTH0512MC NTH0515MC NTH1212MC 5 5 5 12 ±9 ±12 ±15 ±12 ±111 ±83 ±67 ±83 494 488 476 198 81 82 84 84 34 39 37 66 913 465 257 315 NMH0509SC NMH0512SC NMH0515SC NMH1212SC Order Code1 FEATURES „ RoHS compliant „ Efficiency up to 84% „ Wide temperature performance at full 2 Watt load, –40°C to 85°C „ UL 94V-0 package material „ Lead frame technology „ 5V & 12V inputs „ 5V, 9V, 12V & 15V outputs „ Internal SMD construction Nominal Output Output Input Voltage Current Voltage „ MTTF up to 2.17 million hours „ Power density 1.61W/cm3 Efficiency Parameter Voltage range Reflected ripple current Conditions Min. Typ. Max. Units Continuous operation, 5V input types Continuous operation, 12V input types 5V input types 12V input types 4.5 10.8 5 12 40 30 5.5 13.2 V Typ. Max. Units W 1.0 5.0 3.0 150 100 80 70 2.0 7.5 5.0 1.2 10 10 200 150 150 150 Max. Parameter Conditions Rated power 3 „ Custom solutions available Voltage set point accuracy „ Multi layer ceramic capacitors Line regulation TA=-40°C to 85°C NTHXX05, 10% to 100% load All other variants, 10% to 100% load High VIN to low VIN 10% load to rated load, 5V output types 10% load to rated load, all other output types BW=DC to 20MHz, 5V output types BW=DC to 20MHz, 9V output types BW=DC to 20MHz, 12V output types BW=DC to 20MHz, 15V output types Load regulation2 DESCRIPTION For full details go to https://www.murata.com/englobal/products/power/rohs mA p-p OUTPUT CHARACTERISTICS „ No heatsink required The NTH series of miniature surface mounted DC-DC converters employ leadframe technology and transfer moulding techniques to bring all of the benefits of IC style packaging to hybrid circuitry. The component lead termination of this product range is lead-free compatible, therefore the converter can be soldered in a lead-free soldering process. Co-planarity of the lead positions is based upon IEC 191-6:1990. The devices are suitable for all applications where high volume production is envisaged. Isolation MTTF2 Capacitance INPUT CHARACTERISTICS „ Dual isolated output „ 1kVDC isolation Input Current at Rated Load Ripple & noise Min. -5.0 -5.0 % %/% % mV p-p ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Isolation test voltage Resistance Flash tested for 1 second Viso= 500VDC 1000 1 10 Min. Typ. Units VDC GΩ GENERAL CHARACTERISTICS Parameter Conditions Switching frequency All 5V input types All 12V input types 95 90 Max. Units kHz 1. If components are required in tape and reel format suffix order code code with -R, e.g. NTH0505MC-R. 2. Calculated using MIL-HDBK-217F with nominal input voltage at full load. 3. See derating graph. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. www.murata.com KDC_NTH.I01 Page 1 of 9 NTH Series Isolated 2W Dual Output SM DC-DC Converters TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Specification Storage All output types -40 -55 Case temperature rise above ambient Cooling 5V output types All other output types Free air convection Typ. Max. 85 125 30 25 Units °C ABSOLUTE MAXIMUM RATINGS Internal power dissipation Input voltage VIN, NTH05 types Input voltage VIN, NTH12 types 550mW 7V 15V www.murata.com KDC_NTH.I01 Page 2 of 9 NTH Series Isolated 2W Dual Output SM DC-DC Converters TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NTH series of DC-DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the NTH series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NTH series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enamelled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognised parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak reflow solder temperature of 245ºC and time above liquidus of 217ºC for 60 seconds. Please refer to application notes for further information. The pin termination finish on this product series is Gold, plating thickness 0.1 microns minimum. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs PART NUMBER STRUCTURE NTH XX XX M C Series name RoHS compliant Input voltage Package type Output voltage S - SIP D - DIP M - Surface mount Z - ZIP www.murata.com KDC_NTH.I01 Page 3 of 9 NTH Series Isolated 2W Dual Output SM DC-DC Converters CHARACTERISATION TEST METHODS Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC-DC converter 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC-DC converter with an ESR of less than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC-DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. C2 Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input - + R1 T1 R2 Y INPUT Output - R LOAD APPLICATION NOTES Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. NTH0505MC NTH0509MC NTH0512MC NTH0515MC NTH1205MC NTH1209MC NTH1212MC NTH1215MC Start-up time μs 1026 3625 5750 8330 691 2645 3285 6120 Typical Start-Up Wave Form www.murata.com KDC_NTH.I01 Page 4 of 9 NTH Series Isolated 2W Dual Output SM DC-DC Converters APPLICATION NOTES (Continued) Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC-DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC-DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is 20MHz. +VOUT DC Power Source DC L C Load C Load OV -VOUT L NTH0505MC NTH0509MC NTH0512MC NTH0515MC NTH1205MC NTH1209MC NTH1212MC NTH1215MC L, μH 10 22 47 220 10 22 47 220 Inductor SMD 82103C 82223C 82473C 82474C 82103C 82223C 82473C 82474C Through Hole 11R103C 11R223C 11R473C 11R474C 11R103C 11R223C 11R473C 11R474C Capacitor C, μF 4.7 2.2 1 0.22 4.7 2.2 1 0.22 www.murata.com KDC_NTH.I01 Page 5 of 9 NTH Series Isolated 2W Dual Output SM DC-DC Converters TOLERANCE ENVELOPES The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. NTH05XXMC NTH12XXMC 3.75% Output Voltage Output Voltage 7.5% 2.5% 0 -1.25% -5% 10 25 50 75 Output Load Current (%) 5% 1.5% 2% -2% -1.5% -5% 100 10 25 50 75 Output Load Current (%) 100 TEMPERATURE DERATING GRAPH Load (%) 3 85°C 2 1 0 -40 Safe Operating Area 0 50 100 150 Ambient Temperature (°C) www.murata.com KDC_NTH.I01 Page 6 of 9 NTH Series Isolated 2W Dual Output SM DC-DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS 17.78 (0.700) 15.24 (0.600) 17.53-18.03 (0.690-0.710) 26 24 22 18 16 14 DETAIL A 12.70 (0.500) REFERENCE PLANE 0.50 (0.020) NTH0505MC x12 PINS 1.057-1.357 (0.042-0.053) 0.2 (0.008) XYYWW 1 3 5 9 ±5.0° 11 S 13 12 PINS 0.60-0.74 (0.024-0.029) 0.2 (0.008) 2.54 (0.100) -VIN +VIN NA -VOUT OV 13 +VOUT 14 16 18 22 24 26 NA NA -VOUT NC NA NA 2.74 (0.108) MAX DETAIL A 2.75 (0.108) 5.35 (0.236) 6.00 (0.211) Function 1 3 5 9 11 NA - Not available for electrical connection. NC - No internal electrical connection. S 5.25-5.75 (0.207-0.226) Pin S SEATING PLANE 1.52 (0.06) MAX x12 PINS 0.1 (0.004) S 0.25 (0.010) 0.10 (0.004) 0.30 (0.012) 0.20 (0.008) All dimensions in mm (inches). Controlling dimension is mm. Weight: 2.75g Tolerance (unless otherwise stated) ±0.25 (±0.01). All pins on a 2.54 (0.1) pitch. TUBE OUTLINE DIMENSIONS 15.24 (0.600) 20.80 (0.819) 16.50 (0.650) +0.15 2.30 -0.25 2.54 (0.100) All dimensions in mm ±0.5 (inches ±0.02) 0.60 ±0.15 (0.024 ±0.006) +0.031 +0.80 5.80 -0.60 (0.228 -0.024 ) 2.00 (0.079) 14.40 (0.567) RECOMMENDED FOOTPRINT DETAILS +0.006 (0.091 -0.010 ) 1.00 (0.039) MIN All dimensions in mm ±0.5 (inches ±0.02). Tube length: 475 ±2.0 (18.70 ±0.079). Tube Quantity: 25 www.murata.com KDC_NTH.I01 Page 7 of 9 NTH Series Isolated 2W Dual Output SM DC-DC Converters TAPE & REEL SPECIFICATIONS TAPE OUTLINE DIMENSIONS +0.004 +0.10 Ø1.50 -0.00 (Ø0.059 -0.000 ) 330 (12.99) MAX COVER TAPE ±0.05 (0.002) REEL OUTLINE DIMENSIONS 18.33 (0.722) 0.60 (0.024) MAX 24.00 (0.945) 18.43 (0.726) DIRECTION OF UNREELING 10.00 (0.394) Ø2.00 (Ø0.079) MIN 2.00 (0.079) 13.50 (0.531) Ø 12.80 (0.504) 38.4 (1.512) MAX NTH0505MC 32.00±0.30 (1.260±0.012) All dimensions in mm ±0.5 (inches ±0.02) 5.95 (0.234) 6.65 (0.262) 28.40 (1.118) 0.20±0.05 (0.008±0.002) 14.20 (0.559) +0.05 +0.002 R0.75 -0.00 (R0.030 -0.000) XYYWW 1.75 (0.069) 31.9-35.4 (1.256-1.394) (AT HUB SECTION) 4.00 (0.157) 100 Ø (3.94) MIN All dimensions in mm ±0.5 (inches ±0.02) REEL PACKAGING DETAILS Reel Quantity: 400 XYYWW All dimensions in mm ±0.5 (inches ±0.02) NTH0505MC XYYWW NTH0505MC XYYWW NTH0505MC TRAILER SECTION 160 (6.30) MIN GOODS ENCLOSURE SECTION CARRIER TAPE START 100 (3.94) MIN LEADER SECTION 400 (15.75) MIN www.murata.com KDC_NTH.I01 Page 8 of 9 NTH Series Isolated 2W Dual Output SM DC-DC Converters DISCLAIMER Unless otherwise stated in the datasheet, all products are designed for standard commercial and industrial applications and NOT for safety-critical and/or life-critical applications. Particularly for safety-critical and/or life-critical applications, i.e. applications that may directly endanger or cause the loss of life, inflict bodily harm and/or loss or severe damage to equipment/property, and severely harm the environment, a prior explicit written approval from Murata is strictly required. Any use of Murata standard products for any safety-critical, life-critical or any related applications without any prior explicit written approval from Murata shall be deemed unauthorised use. These applications include but are not limited to: • Aircraft equipment • Aerospace equipment • Undersea equipment • Power plant control equipment • Medical equipment • Transportation equipment ( automobiles, trains, ships, etc.) • Traffic signal equipment • Disaster prevention / crime prevention equipment • Data Processing equipment Murata makes no express or implied warranty, representation, or guarantee of suitability, fitness for any particular use/purpose and/or compatibility with any application or device of the buyer, nor does Murata assume any liability whatsoever arising out of unauthorised use of any Murata product for the application of the buyer. The suitability, fitness for any particular use/purpose and/or compatibility of Murata product with any application or device of the buyer remain to be the responsibility and liability of the buyer. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify and hold Murata, its affiliated companies, and its representatives harmless against any damages arising out of unauthorised use of any Murata products in any safety-critical and/ or life-critical applications. Remark: Murata in this section refers to Murata Manufacturing Company and its affiliated companies worldwide including, but not limited to, Murata Power Solutions. This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: https://www.murata.com/en-eu/products/power/requirements Murata Power Solutions (Milton Keynes) Ltd. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2022 Murata Power Solutions (Milton Keynes) Ltd. www.murata.com KDC_NTH.I01 Page 9 of 9
NTH0509MC-R 价格&库存

很抱歉,暂时无法提供与“NTH0509MC-R”相匹配的价格&库存,您可以联系我们找货

免费人工找货