0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ULQ-5/15-D24N-C

ULQ-5/15-D24N-C

  • 厂商:

    MURATA-PS(村田)

  • 封装:

    POWER-MODULE-8P_56.4X34.3MM_TM

  • 描述:

    DC/DC CONVERT 5V 15A

  • 数据手册
  • 价格&库存
ULQ-5/15-D24N-C 数据手册
ULQ Models www.murata-ps.com Single Output, Low-Profile, Quarter-Brick 8-25 Amp Isolated DC-DC Converters Typical units Features ■ Standard quarter-brick package/pinout in through-hole or SMT version ■ Low cost; Low profile, 0.35" (8.9mm) ■ 24V and 48V nominal inputs ■ Output current: 8 to 25 Amps ■ Output voltages: 1.2/1.5/1.8/2/2.5/3.3/5/12V ■ Interleaved synchronous-rectifier topology · Ultra high efficiency · No output reverse conduction ■ Outstanding thermal performance ■ On/off control, trim & sense functions ■ Fully isolated, 2250Vdc (BASIC) ■ Output overvoltage protection ■ Fully I/O protected; Thermal shutdown ■ UL/EN/IEC60950 safety approvals ■ Qual/HALT/EMI tested For applications requiring improved electrical and thermal perfomance at reduced cost DATEL's new ULQ Series "Quarter-Brick" DC-DC Converters suit perfectly. They measure just 1.45 x 2.30 x 0.35 inches (36.8 x 58.4 x 8.9mm) and fit the industry-standard footprint. You can also "pick-andplace" the ULQ-SMT version optimizing your automated SMT process. From an 18-36V or 36-75V input, ULQ's deliver outputs of 1.2, 1.5, 1.8, or 2V fully rated at 15 or 25A, 2.5 or 3.3V at 15 or 20A, 5V at 15A and 12V at 8-10A. They employ an interleaved, synchronous-rectifier topology that exploits 100% of their duty cycle. They simultaneously achieve ultra-high efficiency (to 91%), tight line/load regulation (±0.125/0.25%), low noise (25-70mVp-p), and quick step response (200µsec). A state of the art, single-board, open-frame design with reduced component count, high efficiency, low-on-resistance FET's, and planar magnetics embedded in heavy-copper pc boards all contribute to impressive thermal derating. The ULQ's feature set includes high isolation (2250Vdc), input pi filters, input undervoltage shutdown, output overvoltage protection, current limiting, short-circuit protection and thermal shutdown. The standard footprint carries on/off control (positive or negative logic), output trim (+10/–20%) and output sense functions. All ULQ quarter-bricks are designed to meet the BASIC-insulation requirements of UL/EN/ IEC60950 and they will carry the CE mark. Safety certifications, EMC compliance testing and qualification testing (including HALT) are currently in progress. Contact DATEL for latest updates. +SENSE (7) +VOUT (8) +VIN (1) SWITCH CONTROL –VOUT (4) –VIN (3) –SENSE (5) PWM CONTROLLER REMOTE ON/OFF CONTROL* (2) INPUT UNDERVOLTAGE, INPUT OVERVOLTAGE, AND OUTPUT OVERVOLTAGE COMPARATORS OPTO ISOLATION REFERENCE & ERROR AMP VOUT TRIM (6) * Can be ordered with positive (standard) or negative (optional) polarity. Figure 1. Simplified Schematic Typical topology is shown. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support Typical topology is shown MDC_ULQ-15A.E05 Page 1 of 17 ULQ Models Single Output, Low-Profile, Quarter-Brick 8-25 Amp Isolated DC-DC Converters Performance Specifications and Ordering Guide ➀ ORDERING GUIDE Output Vout Iout ➁ R/N (mVp-p) ➁ (Volts) (Amps) Typ. Max. Root Model ➄ ULQ-1.5/15-D48N-C ULQ-1.5/25-D24P-C ULQ-1.5/25-D48N-C ULQ-1.8/15-D48N-C ULQ-1.8/25-D24P-C ULQ-1.8/25-D48N-C ULQ-2/15-D48N-C ULQ-2/25-D24P-C ULQ-2/25-D48N-C ULQ-2.5/15-D48N-C ULQ-3.3/15-D48NM-C ULQ-3.3/20-D24PM-C ULQ-3.3/20-D48NM-C ULQ-5/15-D24PM-C ULQ-5/15-D48NM-C ULQ-12/8-D24PM-C ULQ-12/10-D48NM-C ULQ-3.3/15-D48N-C ULQ-3.3/20-D24P-C ULQ-3.3/20-D48N-C ULQ-5/15-D24P-C ULQ-5/15-D48N-C ULQ-12/8-D24P-C ULQ-12/10-D48N-C 1.5 1.5 1.5 1.8 1.8 1.8 2 2 2 2.5 3.3 3.3 3.3 5 5 12 12 3.3 3.3 3.3 5 5 12 12 15 25 25 15 25 25 15 25 25 15 15 20 20 15 15 8 10 15 20 20 15 15 8 10 25 50 45 25 50 70 25 50 70 35 45 50 45 50 50 95 90 45 50 45 50 50 95 90 50 100 75 50 100 100 50 100 100 55 75 100 75 100 100 130 130 75 100 75 100 100 130 130 ➀ Typical at TA = +25°C under nominal line voltage and full-load conditions. All models are specified with an external 1µF multi-layer ceramic and 10µF capacitors across their output pins. ➁ Ripple/Noise (R/N) measured over a 20MHz bandwidth. ➂ Devices have no minimum-load requirements and will regulate under no-load conditions. Regulation specifications describe the output voltage deviation as the line voltage or load is varied from its nominal/midpoint value to either extreme. (Load step = 50%.) ULQ-12/8-D24N-C ULQ-12/8-D24NL1-C ULQ-12/8-D24NL2-C ULQ-12/8-D24P-C ULQ-12/10-D48NL1-C ULQ-12/8-D24PL1-C ULQ-3.3/15-D48N-C ULQ-3.3/15-D48P-C ULQ-3.3/15-D48PL1-C ULQ-12/10-D48NL2-C Input Regulation (Max.) Vin Nom. Range IIN ➃ Line Load ➂ (Volts) (Volts) (mA/A) ±0.125% ±0.125% ±0.125% ±0.125% ±0.125% ±0.25% ±0.125% ±0.125% ±0.25% ±0.125% ±0.125% ±0.125% ±0.125% ±0.25% ±0.1% ±0.25% ±0.25% ±0.125% ±0.125% ±0.125% ±0.25% ±0.1% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.4% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.25% ±0.4% ±0.25% ±0.25% 48 24 48 48 24 48 48 24 48 48 48 24 48 24 48 24 48 48 24 48 24 48 24 48 36-75 18-36 36-75 36-75 18-36 36-75 36-75 18-36 36-75 36-75 36-75 18-36 36-75 18-36 36-75 18-36 36-75 36-75 18-36 36-75 18-36 36-75 18-36 36-75 35/0.5 50/1.8 30/0.9 35/0.6 90/2.2 45/1.1 45/0.6 50/2.4 50/1.2 45/0.9 45/1.2 80/3.1 45/1.6 50/3.5 50/1.7 90/4.4 80/2.9 45/1.2 80/3.1 45/1.6 50/3.5 50/1.7 90/4.4 80/2.9 Min. Typ. Package (Case, Pinout) 87% 85.5% 85% 87.5% 85.5% 85.5% 87% 86% 86% 88% 88.5% 87.5% 88% 89% 89% 89% 88% 88.5% 87.5% 88% 89% 89% 89% 88% 89% 87.5% 87% 89% 87.5% 87.5% 89% 88% 88% 89.5% 90.5% 89.5% 90% 91% 91% 90.5% 90% 90.5% 89.5% 90% 91% 91% 90.5% 90% C37, P32 C37, P32 C37, P32 C37, P32 C37, P32 C37, P32 C37, P32 C37, P32 C37, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 C37/C40, P32 Efficiency ➃ Nominal line voltage, no load/full load condition. ➄ Please refer to the Part Number Structure when ordering. ➅ Not all model number combinations are available. Consult Murata Power Solutions. ULQ-3.3/20-D24N-C ULQ-3.3/20-D24NL2-C ULQ-3.3/20-D24P-C ULQ-3.3/20-D24PL1-C ULQ-12/10-D48PL2-C ULQ-3.3/20-D24PL2-C ULQ-5/15-D48N-C ULQ-5/15-D48P-C ULQ-5/15-D48PL2-C PART NUMBER STR UCTURE U LQ - 3.3 / 20 - D48 N M Lx - C Output Configuration RoHS-6 compliant Pin Length Option Quarter-Brick Package Nominal Output Voltage Maximum Rated Output Surface-Mount Package (see list above) Remote On/Off Control Logic Input Voltage Range See page 16 for complete Part Number Structure. www.murata-ps.com/support MDC_ULQ-15A.E05 Page 2 of 17 ULQ Models Single Output, Low-Profile, Quarter-Brick 8-25 Amp Isolated DC-DC Converters Performance/Functional Specifications Typical @ TA = +25°C under nominal line voltage, full-load conditions, unless noted. (1) Input Input Voltage Range: (2) D24 Models D48 Models 18-36 Volts (24V nominal) 36-75 Volts (48V nominal) Overvoltage Shutdown D24 Models D48 Models 37-41 Volts (39V typical) None (3) Start-Up Threshold: (4) D24 Models D48 Models 16-18 Volts (17.5V typical) 34-36 Volts (35V typical) Undervoltage Shutdown: (4) D24 Models D48 Models 15.5-17.5 Volts (16.75V typical) 32.5-34.5 Volts (33.5V typical) Input Current: Normal Operating Conditions Inrush Transient Short Circuit Standby Mode: Off, UV, Thermal Shutdown –40 to +85°C with derating +100°C +105 to 120°C, +115°C typical Physical  Dimensions See Mechanical Dimensions Pin Material (through-hole) Gold-plated copper alloy with nickel underplate Pad Material (SMT) Copper alloy, pure tin over nickel underplate Weight: 1 ounce (28 grams) EMI Conducted and Radiated FCC Part 15, EN55022 may require external filter Safety UL/IEC/EN60950-1 CSA-C22.2 No. 234 4-10mA Internal Input Filter Type Pi 1 minute duration, 5A maximum Remote On/Off Control (Pin 2): (6) Positive Logic ("P" Suffix Models) On = open, open collector or 3.5-13V applied Off = pulled low to 0-0.8V IIN = 6mA max. Negative Logic ("N" Suffix Models) On = pulled low to 0-0.8V IIN = 6mA max. Off = open, open collector or 3.5-13V applied Output Minimum Loading No load VOUT Accuracy (Full Load): Initial Temperature Coefficient Extreme (8) ±1.25% maximum ±0.02% per °C ±3% VOUT Trim Range (9) +10%, –20% Remote Sense Compensation (4) +10% Ripple/Noise (20MHz BW) See Ordering Guide Line/Load Regulation See Ordering Guide Efficiency See Ordering Guide Isolation Voltage: Input-to-Output 2000Vdc minimum, D24 models 2250Vdc minimum, D48 models Isolation Resistance 100MΩ Isolation Capacitance 470pF Current Limit Inception (98% VOUT) (10) After warmup +125% of maximum rated current Short Circuit: (4) Current Duration Hiccup with auto-restart Continuous Overvoltage Protection: (4) OVP method PCB Temperature: (4) (7) Maximum Allowable Thermal Shutdown (4) (14) Primary-to-Secondary Insulation Level Basic 8-50mAp-p Reverse-Polarity Protection Environmental TBD million hours (13) Operating Temperature (Ambient): See derating curves See Ordering Guide 0.05A2 sec maximum 50-100mA Input Reflected Ripple Current (5) (3) Calculated MTBF: VOUT nominal +20% Comparator magnetic feedback Dynamic Characteristics Dynamic Load Response (11) (50% Load Step) 60-300µsec, model dependent Start-Up Time: (4) (12) VIN to VOUT; On/Off to VOUT 30msec typical, 50msec maximum Switching Frequency 160-300kHz, model dependent Maximum Capacitive Load 4700 to 10,000µF, model dependent All models are tested and specified with external output capacitors (1µF ceramic in parallel with 10µF tantalum), unless otherwise noted. These converters have no minimum-load require- ments and will effectively regulate under no-load conditions. (2) Contact Murata Power Solutions for input voltage ranges other than those listed. (3) See Absolute Maximum Ratings for allowable input voltages. (4) See Technical Notes/Performance Curves for additional explanations and details. (5) Input Ripple Current is tested/specified over a 5-20MHz bandwidth with an external 33µF input capacitor and a simulated source impedance of 220µF and 12µH. See I/O Filtering, Input Ripple Current and Output Noise for details. (6) The On/Off Control is designed to be driven with open-collector (or equivalent) logic or the application of appropriate voltages (referenced to –Input (pin 1)). See Remote On/Off Control for more details. (7) All models are fully operational and meet published specifications, including "cold start," at –40°C. (8) Extreme Accuracy refers to the accuracy of either trimmed or untrimmed output voltages over all normal operating ranges and combinations of input voltage, output load and temperature. (9) See Output Trimming for detailed trim equations. (10) The Current-Limit Inception point is the output current level at which the ULQ’s power-limiting circuitry drops the output voltage 2% from its initial value. See Output Current Limiting and Short-Circuit Protection for more details. (11) See Performance Curves for additional information. (12) For the Start-Up Time specifications, output settling is defined by the output voltage having reached ±1% of its final value. (13) MTBF’s are calculated using Telcordia (Bellcore) Method 1 Case 3, ground fixed conditions, +40°C case temperature, and full-load conditions. (1) Absolute Maximum Ratings Input Voltage: Continuous: Transient (100msec): D24V Models See OVP NA D48V Models 81 Volts 100 Volts Input Reverse-Polarity Protection Input Current must be
ULQ-5/15-D24N-C 价格&库存

很抱歉,暂时无法提供与“ULQ-5/15-D24N-C”相匹配的价格&库存,您可以联系我们找货

免费人工找货