0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
VKP60MT515C

VKP60MT515C

  • 厂商:

    MURATA-PS(村田)

  • 封装:

  • 描述:

    VKP60MT515C - 60 Watt Triple Output Half Brick DC/DC Converter - Murata Power Solutions Inc.

  • 数据手册
  • 价格&库存
VKP60MT515C 数据手册
VKP60xTC 60 Watt Triple Output Half Brick DC/DC Converter RoHS Compliant 18 - 40 & 33 - 75V Input Range Each Channel Independently Current Limited High Efficiency: 87% Typical Excellent Cross Regulation 1500VDC Isolation Between Input and Output 500 VDC Channel to Channel Isolation Fixed Frequency Operation Operation to 100°C Baseplate Temperature 50μS Transient Recovery, 0-90% Load Step Primary & Secondary Remote On/Off Adjustable Output Voltage External Synchronization VKP60MT Series UL/cUL approved to UL1950 and VDE approved to EN60950-1 ISO9001 CERTIFIED   For full details go to www.murata-ps.com/rohs The VKP60LTC and VKP60MTC Series are members of the VK high density DC/DC converter family. They are multiple output DC/DC converters offered in both a 18-40 and 33-75 input voltage range. Their versatile architecture featuring fully isolated channels enables the system designer to utilize the converter in either a single, dual or triple output scheme without excessive minimum load requirements or cross regulation degradation. The VKP60xTC’s architecture results in an economical and practical solution for use in distributed power schemes for today’s demanding telecommunication and electronic data processing applications requiring ground separation between noise sensitive digital logic and bipolar analog components. The VKP60xTC’s proprietary control circuity responds to 50-100% load steps in 35μSeconds to within 1% of nominal Vout. The peak deviation will not exceed 7% of Vout for pulsed load slew rates in excess of 75 Amps per microsecond. The VKP60xTC is ideal for electronic data processing applications utilizing modern disk drives and low voltage microprocessors that require dynamic load current response while maintaining tight output voltage tolerances. PRODUCT SELECTION CHART MODEL VKP60LT312C VKP60LT315C VKP60LT512C VKP60LT515C VKP60MT312C VKP60MT315C VKP60MT512C VKP60MT515C INPUT VOLTAGE (VDC) 24 (18-40) 24 (18-40) 24 (18-40) 24 (18-40) 48 (33-75) 48 (33-75) 48 (33-75) 48 (33-75) RATED VOUT (VDC) V1 (±) 3.3 3.3 5.1 5.0 3.3 3.3 5.1 5.0 V2 (±) 12 15 12 15 12 15 12 15 V3 (±) 12 15 12 15 12 15 12 15 V1(±) 18 18 12 12 18 18 12 12 RATED MAXIMUM IOUT (A) V2(±) 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 V3(±) 2.5 2.0 2.5 2.0 2.5 2.0 2.5 2.0 www.murata-ps.com Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000 TDC_VKP60xTC.B01 Page 1 of 7 VKP60xTC 60 Watt Triple Output Half Brick DC/DC Converter SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. PARAMETER Voltage Range VKP60LTXXC Series VKP60MTXXC Series Reflected Ripple Current Input Ripple Current Maximum Input Current VKP60LTXXC Series VKP60MTXXC Series No Load Power Dissipation Inrush Charge VKP60LTXXC Series VKP60MTXXC Series Quiescent Operating Current Primary On/Off Disabled Seconary On/Off Disabled 7.5 15 Peak - Peak DC to 1KHz Output Power = 60 W VIN = 16V VIN = 30V POUT = 0, VIN MIN < VIN < VIN MAX 50 60 6 3 6 0.29 0.165 10 25 CONDITIONS MIN 16 33 TYP 24 48 MAX 40 75 220 UNITS VDC VDC mA dB A A W mC mC mA mA INPUT PARAMETER ISOLATION Input to Output Input to Baseplate Channel to Channel Resistance, Input to Output Capacitance, Input to Output Leakage Current GENERAL Set-point Accuracy Turn-on Time Remote On/Off Control Inputs Primary Sink Current Logic Low Vlow Vhigh Secondary Sink Current Logic Low Vlow Vhigh External Synchronization Input Frequency Pulse Width Source Impedance Input High Voltage Input Low Voltage Input Impedance Switching Frequency Weight CONDITIONS Peak Test Any Channel to Channel MIN 1500 1500 500 10 TYP MAX UNITS VDC VDC VDC MΩ 2000 180 1 3.5 Open Collector/Drain VIN = VIN MAX 5 pF oA, rms % mSec GENERAL 24 48 7 0.8 Open Collector 100 0.4 Open Collector mA V Open Collector/Drain μA V 440 150 4 0 470 470 480 520 320 47 5 1 490 3 (85) KHz nSec Ω V V Ω KHz oz (g) * See Application Notes available on the web at www.murata-ps.com ** X = Either L (24) or M (48) www.murata-ps.com Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000 TDC_VKP60xTC.B01 Page 2 of 7 VKP60xTC 60 Watt Triple Output Half Brick DC/DC Converter SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. PARAMETER CONDITIONS Case temperature -40 -50 +100 Case to Ambient 8.2 +100 +125 +115 ˚C ˚C ˚C ˚C/W MIN TYP MAX UNITS GENERAL continued TEMPERATURE Operation/Specification Storage Shutdown Thermal Impedance PARAMETER Output Power CONDITIONS Total Combined O/P Power = 60 Watts Max. IO Nom V1 Min Nom 30 3.3 9 100 .02 Max 60 18 200 3.80 .05 1.0 1.0 25 250 50 5.0 0 Min V2 Nom 15 12.2 1.25 150 .02 Max 30 2.5 0 250 Dependent on V1 .05 Min V3 Nom 15 12.2 1.25 150 .02 Max 30 2.5 250 .05 UNITS W V A mV V %/°C % % A A mV μSec V % VKP60xT312C** OUTPUT Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency 0.5 DC to 20MHz* * VIN, MinVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=9A, (IOUT2+IOUT3)=2.5A F.L. VIN=Nominal 3.15 0.05 0.50 23 19 150 35 4.2 85 86 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 PARAMETER Output Power Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency CONDITIONS Total Combined O/P Power = 60 Watts Max. IO Nom V1 Min Nom 30 3.3 9 100 .02 Max 60 18 200 3.80 .05 1.0 1.0 25 250 50 5.0 0 Min V2 Nom 15 15.85 1 125 Max 30 Min V3 Nom 15 15.85 1 125 .02 Max 30 2 250 V .05 UNITS W V A mV %/°C % % A A mV μSec V % VKP60xT315** OUTPUT 0.5 DC to 20MHz* See Application Notes* VIN, MinVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=9A, (IOUT2+IOUT3)=2A F.L. VIN=Nominal 4.2 85 3.15 2 0 250 Dependent on V1 .02 .05 0.05 0.50 23 19 150 35 86 1.0 2.0 See Regulation Curves 4.0 3.2 4.0 1.0 2.0 See Regulation Curves 4.0 3.2 4.0 * See Application Notes available on the web at www.murata-ps.com ** X = Either L (24) or M (48) www.murata-ps.com Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000 TDC_VKP60xTC.B01 Page 3 of 7 VKP60xTC 60 Watt Triple Output Half Brick DC/DC Converter SPECIFICATIONS, ALL MODELS Specifications are at TCASE = +40°C nominal input voltage unless otherwise specified. PARAMETER Output Power Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Adjust Range Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency CONDITIONS Total Combind O/P Power = 60 Watts Max IO Nom V1 Min Nom 30 5.1 6.0 125 .02 Max 60 12 200 5.50 .05 0.10 1.0 16 300 50 6.8 0 Min V2 Nom 15 12 1.25 150 Max 30 Min V3 Nom 15 12 1.25 150 .02 Max 30 2.5 250 V .05 UNITS W V A mV %/°C % % A A mV μSec V % VKP60xT512** OUTPUT 0.5 DC to 20MHz* * VIN, MinVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=6A, (IOUT2+IOUT3)=2.5A F.L. VIN=Nomina 4.75 2.5 0 250 Dependent on V1 .02 .05 0.05 0.50 16 12.6 200 35 6.0 86 87 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 1.0 2.0 See Regulation Curves 5.0 4.0 5.0 PARAMETER Output Power Set Point Voltage Output Current, IOUT Output Ripple, p-p Output Temperature Drift Line Regulation Load Regulation Current Limit Inception Short-Circuit Current Transient Response Peak Deviation Settling Time Overvoltage Limit Efficiency CONDITIONS Total Combined O/P Power = 60 Watts Max IO Nom V1 Min Nom 30 5.0 6 100 4.60 .02 0.05 0.50 16 12.6 200 35 6.0 86 87 Max 60 12 200 .05 0.10 1.0 16 300 50 6.8 0 5.50 Min V2 Nom 15 15.3 1 125 .02 Max 30 Min V3 Nom Max 30 2 250 V .05 15 15.3 2 0 1 250 125 Dependent on V1 .05 .02 UNITS W V A mV %/°C % % A A mV μSec V % VKP60xT515** OUTPUT 0.5 DC to 20MHz* Output Adjust Range VIN, MinVIN, Max IO = IO, Nom Min Load to Rated Load Other Outputs Min Load 50 to 100% Load Step VOUT, 1% of VOUT, Nom IOUT1=6A, (IOUT2+IOUT3)=2A F.L. VIN=Nominal * 1.0 2.0 See Regulation Curves 4.0 3.2 4.0 1.0 2.0 See Regulation Curves 4.0 3.2 4.0 * See Application Notes available on the web at www.murata-ps.com ** X = Either L (24) or M (48) VKp60 xTyz- L C ORDERING INFORMATION Device Family Indicates 100 Watt Regulated Unit Model Number Selected from Table of Electrical Characteristics Where: x = Input Voltage (L = 24VDC, M = 48VDC) T = Number of Outputs (Triple ‘T’) y = 3 for 3.3V, 5 for 5V z = 12 for 12V, 15 for 15V Lead Length 0.250" - No Number 0.145" - (6) 0.110" - (8) RoHS Compliant www.murata-ps.com Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000 TDC_VKP60xTC.B01 Page 4 of 7 VKP60xTC 60 Watt Triple Output Half Brick DC/DC Converter TYPICAL PERFORMANCE CURVES Specifications are at TCASE = +40°C nominal input voltage, nominal load, recommended external components applied, unless otherwise specified. (Refer to Application Note DCAN-9 at www.murata-ps.com) EFFICIENCY vs TEMPERATURE TCASE = +40°C, nominal input voltage, nominal load, recommended external components applied, unless otherwise specified.* ABSOLUTE MAX. RATINGS Output Short-Circuit Duration Baseplate Temperature Lead Temperature (soldering, 10 seconds max) Storage Temperature Input to Output Isolation Continuous +100°C +300°C +125°C 1500 VDC Change in Efficiency (%) Case Temperature (°C) www.murata-ps.com Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000 TDC_VKP60xTC.B01 Page 5 of 7 VKP60xTC TYPICAL PERFORMANCE CURVES 60 Watt Triple Output Half Brick DC/DC Converter VKP60xT312 VKP60xT315 VKP60xT512 VKP60xT515 www.murata-ps.com Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000 TDC_VKP60xTC.B01 Page 6 of 7 VKP60xTC 60 Watt Triple Output Half Brick DC/DC Converter MECHANICAL NOTES: All dimensions are in inches (millimeters). PIN PLACEMENT TOLERANCE: ± 0.005” MECHANICAL TOLERANCE: ± 0.015” Marked with: specific model ordered, date code, job code. MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance, wide operating temperature range, and good electrical properties under high humidity environments. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is matte tin 100 microinches min., over nickel, 40-80 microinches. [A] See Ordering Information on page 4 for available lead lengths. PIN CONNECTIONS 1 2 3 4 5 6 7 8 9 10 11 12 PRIMARY ON/OFF -VIN +VIN SYNC IN -V2 +V2 TRIM +V1 -V1 SECONDARY ON/OFF +V3 -V3 PIN SIDE DOWN PIN SIDE UP SIDE VIEW USA: Canada: UK: France: Tucson (AZ), Tel: (800) 547 2537, email: sales@murata-ps.com Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com ISO 9001 REGISTERED Japan: email: sales@murata-ps.com 3/06/08 China: Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. www.murata-ps.com Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000 TDC_VKP60xTC.B01 Page 7 of 7
VKP60MT515C 价格&库存

很抱歉,暂时无法提供与“VKP60MT515C”相匹配的价格&库存,您可以联系我们找货

免费人工找货