0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ADZ12124V

ADZ12124V

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    POWERRELAY120A1COILVERT24V

  • 数据手册
  • 价格&库存
ADZ12124V 数据手册
Automation Controls Catalog IEC62055-31 UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays New Horizontal terminal type New DZ RELAYS (ADZ) FEATURES TYPICAL APPLICATIONS 1. IEC62055-31 UC3 compliant (short current 3,000 A) 2. High switching capacity 120 A 250 VAC (Resistive load) 3. Twin contacts for low temperature rise 4. Low operating power 1 coil latching: 1.4 W 2 coil latching: 2.8 W 5. Small size: W: 41 x L: 35 x H: 22 mm W: 1.614 x L: 1.378 x H: .866 inch 1. Smart meters 2. Charge station 3. Other industrial equipment Vertical terminal type RoHS compliant Protective construction: Dust cover type ORDERING INFORMATION ADZ 2 1 Operating function 1: 1 coil latching 2: 2 coil latching Contact capacity 2: 120 A Contact material 1: AgSnO2 type Nominal coil voltage (DC) 05: 5 V, 12: 12 V, 24: 24 V Terminal shape H: Horizontal type V: Vertical type TYPES Part No. Contact arrangement Nominal coil voltage 1 Form A 12 V DC 24 V DC 5 V DC 1 coil latching Horizontal terminal type Vertical terminal type ADZ12105H ADZ12105V ADZ12112H ADZ12124H ADZ12112V ADZ12124V 2 coil latching Horizontal terminal type Vertical terminal type ADZ22105H ADZ22105V ADZ22112H ADZ22124H ADZ22112V ADZ22124V Standard packing: Carton: 20 pcs.; Case: 100 pcs. 2014.02 industrial.panasonic.com/ac/e/ –1– © Panasonic Corporation 2014 ASCTB338E 201402-T DZ (ADZ) RATING 1. Coil data 1) 1 coil latching Nominal coil voltage Set voltage (at 20°C 68°F) Reset voltage (at 20°C 68°F) 5 V DC *70%V or less of nominal voltage (Initial) *70%V or less of nominal voltage (Initial) 12 V DC 24 V DC Nominal operating current [±10%] (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) 280.0 mA 17.9 Ω 116.7 mA 58.3 mA 102.9 Ω 411.4 Ω 1,400 mW 130%V of nominal voltage Nominal operating current [±10%] (at 20°C 68°F) Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) 2,800 mW 130%V of nominal voltage 2) 2 coil latching Nominal coil voltage Set voltage (at 20°C 68°F) Reset voltage (at 20°C 68°F) 5 V DC *70%V or less of nominal voltage (Initial) *70%V or less of nominal voltage (Initial) 12 V DC 24 V DC 560.0 mA 8.9 Ω 233.3 mA 116.7 mA 51.4 Ω 205.7 Ω *Pulse drive (JIS C 5442-1996) 2. Specifications Characteristics 1 coil latching 2 coil latching 1 Form A Max. 0.12V (at 120A), Max. 0.10V (at 20A) AgSnO2 type 120 A 250 V AC 30,000 VA 276 V AC 120 A AC 1,400 mW (1 coil latching) 2,800 mW (2 coil latching) 100 mA 24 V DC Arrangement Contact voltage drop Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Contact Rating Insulation resistance (Initial) Between open contacts Between contact and coil Overcurrent resistance (Initial) Surge breakdown voltage*2 (Between contact and coil) Set time (at 20°C 68°F) Reset time (at 20°C 68°F) Breakdown voltage (Initial) Electrical characteristics Shock resistance Mechanical characteristics Vibration resistance Functional Destructive Functional Destructive Mechanical Expected life* Resistive load 3 Conditions Specifications Item Electrical UC3 class Conditions for operation, transport and storage*3 Unit weight Min. 1,000 MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section. 2,000 Vrms for 1min. (Detection current: 10 mA) 4,000 Vrms for 1min. (Detection current: 10 mA) Min. 3,000 A (Half-wave pulse of sine wave: 10 ms)*4 12,000 V (Initial) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time) 300 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 µs) 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms) 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10 µs) 10 to 55 Hz at double amplitude of 2.0 mm Min. 105 (at 180 times/min.) 120 A 250 V AC Min. 103 (operating frequency: ON : OFF = 10 s : 20 s) 100 A 276 V AC Min. 104 (cosφ = 1.0 : 5,000, cosφ = 0.5 : 5,000, operating frequency: ON : OFF = 10 s : 20 s)*5 Ambient temperature: –40°C to +85°C –40°F to +185°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 75 g 2.65 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2 × 50 µs according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, operation, transport and storage conditions in NOTES. *4. IEC62055-31 UC3 compliant *5. Based on IEC62055-31 UC3, inductive load test was conducted after resistive load test, and expressed as total. Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –2– © Panasonic Corporation 2014 ASCTB338E 201402-T DZ (ADZ) DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 1. Horizontal terminal type External dimensions CAD Data 3.2 dia. .126 dia. 22.0±0.5 .866±.020 35.0±0.5 1.378±.020 3.5 .138 14.2±0.5 .559±.020 Schematic (Top view) 1 coil latching 9.6 .378 2 coil latching + 3.0 .118 Set Coil − + − Reset Coil − 5.0 .197 41.0±0.5 1.614±.020 17.0±0.4 .669±.016 3.5 .138 2.5 .098 2 coil latching only NO COM 12.0±0.4 .472±.016 10.0 .394 2-4.3 dia. 2-.169 dia. 4.7±0.4 .185±.016 7.0 .276 12.0±0.4 .472±.016 7.4±0.4 .291±.016 21.4±0.5 .843±.020 10.0 .394 2.0 .079 NO COM 10.0 .394 2.0 .079 3-▫0.64 3-▫.025 11.7±0.5 .461±.020 8.1±0.5 .319±.020 General tolerance: ±0.3 ±.012 2. Vertical terminal type External dimensions CAD Data 3.2 dia. .126 dia. 22.0±0.5 .866±.020 14.2±0.5 .559±.020 41.0±0.5 1.614±.020 35.0±0.5 1.378±.020 3.5 .138 Schematic (Top view) 1 coil latching 9.6 .378 2 coil latching + 3.0 .118 Set Coil − + − Reset Coil − 5.0 .197 3.5 .138 2.5 .098 NO COM NO COM 2 coil latching only 12.0±0.4 .472±.016 17.0±0.4 .669±.016 1.2 .047 4.5 .177 2-4.3 dia. 2-.169 dia. 10.0±0.5 .394±.020 4.7±0.4 .185±.016 7.4±0.4 .291±.016 2.0 .079 3-▫0.64 3-▫.025 10.0 .394 8.1±0.5 .319±.020 2.0 .079 10.0 .394 General tolerance: ±0.3 ±.012 SAFETY STANDARDS VDE (Certified) File No. 40038931 Contact rating 120A 250V AC (cosφ =1.0) Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –3– © Panasonic Corporation 2014 ASCTB338E 201402-T DZ (ADZ) NOTES 1. For cautions for use, please read “GENERAL APPLICATION GUIDELINES” on page B-1. 2. Operation, transport and storage Following is the conditions of ambient temperature, humidity and air pressure in case of operation, transport and storage. 1) Ambient temperature: –40 to +85°C –40 to +185°F (Max.100A over 70°C 158°F) 2) Humidity: 5 to 85%RH (Not freezing and condensing) In addition the humidity range depends on temperature. The allowable ranges are as follows; 3) Air pressure: 86 to 106kPa Allowable range of ambient temperature and humidity for operation, transport and storage. Humidity, %RH 85 Allowable range (Not freezing (Not condensing below above 0°C 32°F) 0°C 32°F) 5 –40 –40 0 +32 Ambient temperature, °C °F 85 +185 4) Condensing Condensing occurs when the relay is exposed to sudden temperature change in a high-temperature, high-humidity atmosphere. This may cause some troubles like insulation failure. 5) Freezing At temperature below 0°C 32°F, moisture may freeze. This may lead to some troubles like sticking of the moving portion of the relay or delayed operation. 6) Low-temperature, low-humidity atmosphere If the relay is exposed to a lowtemperature, low-humidity atmosphere for a long time, its plastic parts may become brittle and fragile. 3. Soldering and cleaning 1) In case of soldering, following conditions should be observed. Manual soldering: Max. 260°C 500°F (solder temperature) within 10s (soldering time) Max. 350°C 662°F (solder temperature) within 3s (soldering time) * Furthermore, because the type of PC board used and other factors may influence the relays, test that the relays function properly on the actual PC board on which they are mounted. 2) Since this is not a sealed type relay, do not clean it as is. Also, be careful not to allow flux to overflow above the PC board or enter the inside of the relay. 4. Terminal installation condition Installation torque for contact terminal (M4): 1.2 to 1.4 N·m 5. Cautions for use 1) This relay is designed to dust cover type. Malfunction and contact failure may result if small insects get inside the relay. 2) Installation of M4 securing screw for contact terminal Do not apply excessive pressure on the terminals. This could adversely affect relay performance. Use a washer in order to prevent deformation. Keep the installation torque to within 1.2 to 1.4 N·m (12 to 14 kgf·cm). Also, use a spring washer to prevent it from loosening. 3) Through hole on the relay is for temporary fixing use. Do not fix relay through hole only. Panasonic Corporation Automation Controls Business Division industrial.panasonic.com/ac/e/ –4– © Panasonic Corporation 2014 ASCTB338E 201402-T
ADZ12124V 价格&库存

很抱歉,暂时无法提供与“ADZ12124V”相匹配的价格&库存,您可以联系我们找货

免费人工找货