AGQ20TS2HZ

AGQ20TS2HZ

  • 厂商:

    NAIS(松下)

  • 封装:

    SMD8

  • 描述:

    RELAYGENPURPOSEDPDT2A2.4V

  • 数据手册
  • 价格&库存
AGQ20TS2HZ 数据手册
Signal Relays ( 2 A or less ) GQ RELAYS TH Types Product Catalog 2022.10 Signal Relays ( 2 A or less ) GQ RELAYS TH types Small size controlled 3.5 A inrush current possible FEATURES Protective construction:Sealed type ● Small size controlled 3.5 A inrush current possible 10.6 ● 2.4 coil voltage type newly available DC battery operation 7.2 5.2 10.6 ● Flat compact size 10.6 ( L ) × 7.2 ( W ) × 5.2 ( H ) mm 7.2 5.4 TYPICAL APPLICATIONS ● Thermostat ( HVAC temperature controller ) ● Others, High-capacity control etc. (Unit:mm) ORDERING INFORMATION ( PART NO. ) AGQ 2 Operating function 0 : Single side stable 1 : 1 coil latching Contact arrangement 2 : 2 Form C T Packing style*1 Nil : Tube packing X : Tape and reel packing (picked from 1/2/3/4-pin side) Z : Tape and reel packing (picked from 5/6/7/8-pin side) W : Tape and reel packing (picked from the 1/2/3/4-pin side) With humidity indicator and silica gel in moisture proof bag*3 Y : Tape and reel packing (picked from the 5/6/7/8-pin side) With humidity indicator and silica gel in moisture proof bag*3 Terminal shape Nil : Standard PC board terminal A : Surface-mount terminal A type S : Surface-mount terminal S type Type of operation T : Power type(B.B.M.) Rated coil voltage(DC)*2 1H:1.5V, 2H:2.4V, 03:3V, 4H:4.5V, 06:6V, 09:9V, 12:12V, 24:24V *1. The“W”and“Y”at the end of the part number only appears on the inner and outer packing. It does not appear on the relay itself. *2. Please inquire if you require a relay, between 1.5 and 24 V DC, with a voltage not listed. *3. Each reel is packed with humidity indicators and silica gel in the moisuture proof pack. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー1ー Panasonic Industry Co., Ltd. 2022 ASCTB375E 202210 Signal Relays ( 2 A or less ) GQ RELAYS TH types TYPES ■ PC board terminal ● Tube packing Contact arrangement Rated coil voltage 2 Form C Part No. Standard packing Single side stable 1 coil latching 1.5 V DC AGQ20T1H AGQ21T1H 2.4 V DC AGQ20T2H AGQ21T2H 3 V DC AGQ20T03 AGQ21T03 4.5 V DC AGQ20T4H AGQ21T4H 6 V DC AGQ20T06 AGQ21T06 9 V DC AGQ20T09 AGQ21T09 12 V DC AGQ20T12 AGQ21T12 24 V DC AGQ20T24 AGQ21T24 Carton ( 1 Tube packing ) Outer carton 50 pcs. 1,000 pcs. ■ Surface-mount terminal ● Tube packing Contact arrangement 2 Form C Rated coil voltage Part No. Standard packing Single side stable 1 coil latching 1.5 V DC AGQ20T*1H AGQ21T*1H 2.4 V DC AGQ20T*2H AGQ21T*2H 3 V DC AGQ20T*03 AGQ21T*03 4.5 V DC AGQ20T*4H AGQ21T*4H 6 V DC AGQ20T*06 AGQ21T*06 9 V DC AGQ20T*09 AGQ21T*09 12 V DC AGQ20T*12 AGQ21T*12 24 V DC AGQ20T*24 AGQ21T*24 Carton ( 1 Tube packing ) Outer carton 50 pcs. 1,000 pcs. Note) " * " : For each surface-mount terminal identitication, input the following letter. A type: A, S type: S. ● Tape and reel packing: Z Contact arrangement 2 Form C Rated coil voltage Part No. Standard packing Single side stable 1 coil latching 1.5 V DC AGQ20T*1HZ AGQ21T*1HZ 2.4 V DC AGQ20T*2HZ AGQ21T*2HZ 3 V DC AGQ20T*03Z AGQ21T*03Z 4.5 V DC AGQ20T*4HZ AGQ21T*4HZ 6 AGQ20T*06Z AGQ21T*06Z V DC 9 V DC AGQ20T*09Z AGQ21T*09Z 12 V DC AGQ20T*12Z AGQ21T*12Z 24 V DC AGQ20T*24Z AGQ21T*24Z Carton ( 1 Reel packing ) Outer carton 900 pcs. 1,800 pcs. Notes) 1: " * " : For each surface-mount terminal identitication, input the following letter. A type: A, S type: S. 2: For taping packaging X, W, and Y, change " Z " at the end of the part number to " X ", " W ", and " Y ". 3: Please inquire if you require a relay, between 1.5 and 24 V DC, with a voltage not listed. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー2ー Panasonic Industry Co., Ltd. 2022 ASCTB375E 202210 Signal Relays ( 2 A or less ) GQ RELAYS TH types RATING ■ Coil data • Operating characteristics such as " Operate voltage " and " Release voltage " are influenced by mounting conditions or ambient temperature, etc. Therefore, please use the relay within ±5 % of rated coil voltage. • " Initial " means the condition of products at the time of delivery. ● Single side stable Rated coil voltage Operate voltage ( at 20 ℃ ) Release voltage ( at 20 ℃ ) Rated operating current ( ±10 %, at 20 ℃ ) Coil resistance ( ±10 %, at 20 ℃ ) 1.5 V DC 93.8 mA 16 Ω 2.4 V DC 58.5 mA 41 Ω 3 46.7 mA 64.2 Ω V DC 4.5 V DC 6 V DC 9 V DC 12 24 Max. 75 % V of rated coil voltage* ( Initial ) Min. 10 % V of rated coil voltage* ( Initial ) 31 mA 145 Ω 23.3 mA 257 Ω 15.5 mA 579 Ω V DC 11.7 mA 1,028 Ω V DC 9.6 mA 2,504 Ω Rated operating power Max. allowable voltage ( at 20 ℃ ) 140 mW 150 % V of rated coil voltage 230 mW 120 % V of rated coil voltage Rated operating power Max. allowable voltage ( at 20 ℃ ) ● 1 coil latching Rated coil voltage Set voltage ( at 20 ℃ ) Reset voltage ( at 20 ℃ ) Rated operating current ( ±10 %, at 20 ℃ ) Coil resistance ( ±10 %, at 20 ℃ ) 1.5 V DC 66.7 mA 22.5 Ω 2.4 V DC 41.7 mA 57.6 Ω 3 33.3 mA V DC 4.5 V DC 6 V DC Max. 75 % V of rated coil voltage* ( Initial ) Max. 75 % V of rated coil voltage* ( Initial ) 90 Ω 22.2 mA 202.5 Ω 16.7 mA 360 Ω 9 V DC 11.1 mA 810 Ω 12 V DC 8.3 mA 1,440 Ω 24 V DC 5.0 mA 4,800 Ω 100 mW 150 % V of rated coil voltage 120 mW * Pulse drive ( JIS C 5442-1996 ) Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー3ー Panasonic Industry Co., Ltd. 2022 ASCTB375E 202210 Signal Relays ( 2 A or less ) GQ RELAYS TH types ■ Specifications Item Contact data Rated operating power Specifications Contact arrangement 2 Form C Contact resistance ( Initial ) Max. 100 mΩ ( by voltage drop 6 V DC 1 A ) Contact material AgNi + Au plating Contact rating ( resistive ) 2 A 30 V DC, 1 A 30 V DC, 0.3 A 125 V AC Max. switching power ( resistive ) 60 W ( DC ), 30 W ( DC ), 37.5 V A ( AC ) Max. switching voltage 110 V DC, 125 V AC Max. switching current 2 A ( AC, DC ) Min. switching load ( Reference value )*1 10 µA 10 mV DC Single side stable 140 mW ( 1.5 to 12 V DC ), 230 mW ( 24 V DC ) 1 coil latching 100 mW ( 1.5 to 12 V DC ), 120 mW ( 24 V DC ) Min. 1,000 MΩ ( at 500 V DC ) Measured portion is the same as the case of dielectric voltage Insulation resistance ( Initial ) Dielectric strength ( initial ) Between open contacts 750 Vrms for 1 min ( detection current: 10 mA ) Between contact and coil 1,500 Vrms for 1 min ( detection current: 10 mA ) Between contact sets 1,000 Vrms for 1 min ( detection current: 10 mA ) Surge withstand voltage ( Initial ) Between open contacts 1,500 V ( 10 × 160 µs ) ( FCC Part 68 ) Between contact and coil 2,500 V ( 2 × 10 µs ) ( Telcordia ) Max. 50 ℃ ( By resistive method, rated coil voltage applied to the coil; contact carrying current: 2 A ) Temperature rise ( at 20 ℃ ) Time characteristics ( initial ) Shock resistance Vibration resistance Expected life Conditions Operate time ( Set time ) ( at 20 ℃ ) Max. 4 ms ( Max. 4 ms ) ( Rated coil voltage applied to the coil, excluding contact bounce time. ) Release time ( Reset time ) ( at 20 ℃ ) Max. 4 ms ( Max. 4 ms ) ( Rated coil voltage applied to the coil, excluding contact bounce time. ) ( without diode ) Functional 750 m/s2 ( half -sine shock pulse: 6 ms; detection time: 10 µs ) Destructive 1,000 m/s2 ( half -sine shock pulse: 6 ms. ) Functional 10 to 55 Hz at double amplitude of 3.3 mm ( detection time: 10 µs ) Destructive 10 to 55 Hz at double amplitude of 5.0 mm Mechanical Min. 50 × 106 ope. ( at 180 cpm ) Electrical Min. 100 × 103 ope. ( 1 A 30 V DC resistive ) Min. 100 × 103 ope. ( 3.5 A inrush (250 ms) / 1 A 30 V AC ( cosφ=0.4)) ( ON/OFF=1 s/9 s ) Conditions for operation, transport and storage*2 Ambient temperature: ( Single side stable, 1 coil latching type ) −40 to +85 ℃ Humidity: 5 to 85% RH ( Avoid icing and condensation ) Unit weight Approx. 1.0 g *1: This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2: Refer to " AMBIENT ENVIRONMENT " in GENERAL APPLICATION GUIDELINES. REFERENCE DATA 1. Electrical life ( 100 × 103 operation is possible ) Condition:30 V AC Inrush current:3.5 A(effective value), inrush time 250 ms steady current:1.0 A(effective value), (Inductive load cosφ = 0.4) Tested sample:AGQ21TA03, 6 pcs. Switching frequency:ON:OFF = 1s:9s C Ambient temperature:25° Circuit: Inrush current wave form vs time COM1 30V AC 60Hz NO1 − 24V + G Detection Circuit Contact Weld Min 0.5s Miss Contact after 0.2s Contact current, A 6 4 2 0 -2 -4 -6 Time(ms), Interval(100ms) Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー4ー Panasonic Industry Co., Ltd. 2022 ASCTB375E 202210 Signal Relays ( 2 A or less ) GQ RELAYS TH types DIMENSIONS ( Unit: mm ) CAD The CAD data of the products with a " CAD " mark can be downloaded from our Website. ■ PC board terminal CAD External dimensions Recommended PC board pattern ( BOTTOM VIEW ) 2.2 2.2 5.2±0.2 3.2 7.2±0.3 1 5.08 10.6±0.3 Schematic ( BOTTOM VIEW ) Single side stable ( De-energize ) 2 3 4 + φ0.85 Tolerance:±0.1 2.2±0.15 2.2±0.15 0.2±0.1 5.08±0.15 3.5±0.3 0.4±0.1 3.2±0.15 8 7 6 5 Direction indication 1 coil latching ( Reset ) 1 2 3 4 + 8 7 6 5 Direction indication ■ Surface-mount terminal CAD Type Recommended PC board pattern ( TOP VIEW ) External dimensions Schematic ( TOP VIEW ) Single side stable ( De-energize ) 8 6.74 0.8 0.4±0.1 3.2±0.15 2.2±0.15 2.2±0.15 Tolerance : ±0.1 0.2±0.1 6 5 + 7.2±0.3 2.66 A Max. 5.4 10.6±0.3 3.2 7 2.2 2.2 5.08±0.15 1 2 3 4 Direction indication 1 coil latching ( Reset ) 8.4±0.3 8 7 6 5 + 2.06 7.2±0.3 1 2 3 4 Direction indication 6.14 Max. 5.4 10.6±0.3 S 3.2 2.2 2.2 0.8 0.4±0.1 3.2±0.15 2.2±0.15 2.2±0.15 0.2±0.1 7.2±0.3 5.08±0.15 Tolerance : ±0.1 Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー5ー Panasonic Industry Co., Ltd. 2022 ASCTB375E 202210 Signal Relays ( 2 A or less ) GQ RELAYS TH types PACKING STYLE ( Unit: mm ) ■ Tube packing 1) The relay is packing in a tube with the relay orientation mark on the left side,as shown in the figure below. Be sure to maintain relays in the correct orientation when mounting on PC boards. 2) Conditions for operation, transport and storage: −40 to 70 ℃. STD Type Orientation(indicates PIN No.1)stripe Stopper(green) Stopper(red) SMD Type Orientation(indicates PIN No.1)stripe Stopper(green) Stopper(red) ■ Taping packaging 2) Dimensions of plastic reel 1) Tape dimensions A Type φ21±0.8 12 4 φ2 9 0.4 2±0.5 Max. 6.55 GQ relays φ330±2 2 φ80±1 φ1.5  +00.1 11.1 11.5 1.75 24±0.3 Relay polarity bar (Z type) Tape coming out direction General tolerance : ±0.1 φ13±0.2 24.4+ 20 2±0.2 Relay polarity bar 0.1 φ1.5+  0 2 4 φ2 11.1 (Z type) 12 7.8 11.5 1.75 24±0.3 S Type 0.4 3) Conditions for operation, transport and storage: ‒40 to 70 ℃. Max. 6.55 GQ relays Tape coming out direction General tolerance : ±0.1 Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー6ー Panasonic Industry Co., Ltd. 2022 ASCTB375E 202210 Signal Relays ( 2 A or less ) GQ RELAYS TH types EXAMPLE OF RECOMMENDED SOLDERING CONDITIONS ■ For cautions for use, please read " Relay Soldering and Cleaning Guidelines " and " SMT Soldering Guidelines ". ■ PC board terminal In case of hand soldering, the following conditions should be observed. The effect on the relay depends on the PC board used. Please verify the actual PC board to be used. ● Automatic soldering ( Flow ) Recommended conditions Temperature Preheating Soldering ● Hand soldering Time Measurement location Recommended conditions Temperature Time Measurement location Max. 120 ℃ Within 120 seconds Solder surface terminal Soldering Max. 350 ℃ Within 3 seconds Tip temperature 260 ℃ ±5 ℃ Within 6 seconds Solder temperature ■ Surface-mount terminal In case of automatic soldering ( reflow ), the following conditions should be observed. ● IRS ( infrared reflow soldering method ) heating conditions Recommend conditions Number of reflow 1 time Measuring position Surface of PC board where relay is mounted. t4 T3 T2 T1 t1 t2 t3 t 1=60s to 120s t 2=within 20s t 3=within 30s C) t 4=within 10s(245 to 250° T1=150 to 180° C C and higher T2=230° C max T3=250° ● Mounting cautions Cautions to observe when mounting temperature increases in the relay are greatly dependent on the way different parts are located a PC board and the heating method of the reflow device. Therefore, please conduct testing on the actual device beforehand after making sure the parts soldered on the relay terminals and the top of the relay case are within the temperature conditions. Measuring position of temperature profile Note Note:7KHVROGHULQJWHPSHUDWXUHSURŏOH indicates the pad temperature. In some cases, the ambient temperature may be greatly LQFUHDVHG&KHFNIRUWKHVSHFLŏF mounting condition. ■ Other things to observe • Exceeding the stipulated conditions when soldering may affect coaxial switch performance. Be sure to consult us beforehand. • Since thermal stress on a relay will depend on the PC board and process conditions, please be sure to test using the actual PC board. • Creep-up, wettability and solder strength will differ depending on changes in the mounting conditions and type of solder. Please evaluate based on actual production conditions. • Only apply coating after the relay has returned to room temperature. SAFETY STANDARDS Each standard may be updated at any time, so please check our Website for the latest information. ■ UL/C-UL ( Approved ) File No. E43149 Contact rating ■ CSA ( Approved ) Operations Ambient temperature 2 A 30 V DC Resistive 50 × 103 40 ℃ 1 A 30 V DC Resistive 100 × 103 40 ℃ 6 × 103 85 ℃ 0.3 A 110 V DC Resistive 30 × 103 40 ℃ 0.3 A 125 V AC Resistive 100 × 103 40 ℃ 0.5 A 60 V DC Resistive* CSA standard approved by C-UL. * Single side stable type 1.5 to 12 V DC only ■ BSI ( Approved ) BSI standard approved by File No. VC667389 ( basic insulation ). Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー7ー Panasonic Industry Co., Ltd. 2022 ASCTB375E 202210 Signal Relays ( 2 A or less ) GQ RELAYS TH types GUIDELINES FOR USAGE ■ For cautions for use, please read " GUIDELINES FOR SIGNAL RELAYS USAGE " and " GUIDELINES FOR RELAY USAGE ". ■ Cautions for usage of GQ relay TH type ● Latching • Use latching when conditions involve continuous carrying current. • Regarding the set and reset pulse time, for the purpose of reliable operation under ambient temperature fluctuations and different operating conditions, we recommend setting the coil applied set and reset pulse time to 10 ms or more at the rated coil voltage. • The relay is shipped in the reset position. But jolts during transport or impacts during installation can change the reset position. It is, therefore, advisable to build a circuit in which the relay can be initialized ( set and reset ) just after turning on the power. ● Precaution When using at 3.5 A, connection of NO ( pin #5 and #8 ) and COM ( pin #4 and #9 ) in the circuit is required. ● Precautions for usage of automatic insertion machine Set the chucking pressure of the pick-up mechanism by the automatic mounting machine with the pressure shown in table 1 to maintain the internal function of the relay. C A B Please chuck the   portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be also avoided. Table 1: Chucking pressure A to C direction Max. 9.8 N ( 1 kgf ) Pin layout and schematic (BOTTOM VIEW)1 coil latching 1 2 3 4 8 7 6 5 Load Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー8ー Panasonic Industry Co., Ltd. 2022 ASCTB375E 202210 GUIDELINES FOR SIGNAL RELAYS USAGE ■ For cautions for use, please read " GUIDELINES FOR RELAY USAGE ". https://industrial.panasonic.com/ac/e/control/relay/cautions_use/index.jsp PRECAUTIONS FOR COIL INPUT ■ Long term current carrying ■ Coil connection A circuit that will be carrying a current continuously for long periods without relay switching operation. ( circuits for emergency lamps, alarm devices and error inspection that, for example, revert only during malfunction and output warnings with form B contacts ) Continuous,long-term current to the coil will facilitate deterioration of coil insulation and characteristics due to heating of the coil itself. For circuits such as these, please use a magnetic-hold type latching relay. If you need to use a single stable relay, use a sealed type relay that is not easily affected by ambient conditions and make a failsafe circuit design that considers the possibility of contact failure or disconnection. When connecting coils of polarized relays, please check coil polarity ( +, − ) at the internal connection diagram ( Schematic ). If any wrong connection is made, it may cause unexpected malfunction, like abnormal heat, fire and so on, and circuit do not work. Avoid impressing voltages to the set coil and reset coil at the same time. ■ DC Coil operating power Steady state DC current should be applied to the coil. The wave form should be rectangular. If it includes ripple, the ripple factor should be less than 5 %. However, please check with the actual circuit since the electrical characteristics may vary. The rated coil voltage should be applied to the coil and the set/reset pulse time of latching type relay differs for each relays, please refer to the relay's individual specifications. ■ Maximum allowable voltage and temperature rise Proper usage requires that the rated coil voltage be impressed on the coil. Note, however, that if a voltage greater than or equal to the maximum continuous voltage is impressed on the coil, the coil may burn or its layers short due to the temperature rise. Furthermore, do not exceed the usable ambient temperature range listed in the catalog. ● Operate voltage change due to coil temperature rise ( hot start ) In DC relays, after continuous passage of current in the coil, if the current is turned OFF, then immediately turned ON again, due to the temperature rise in the coil, the operate voltage will become somewhat higher. Also, it will be the same as using it in a higher temperature atmosphere. The resistance/temperature relationship for copper wire is about 0.4 % for 1 ℃, and with this ratio the coil resistance increases. That is, in order to operate of the relay, it is necessary that the voltage be higher than the operate voltage and the operate voltage rises in accordance with the increase in the resistance value. However, for some polarized relays, this rate of change is considerably smaller. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー9ー Panasonic Industry Co., Ltd. 2022 ASCTB414E 202210 GUIDELINES FOR SIGNAL RELAYS USAGE NOTES ■ Usage, Storage, and Transport Conditions During usage, storage, or transportation, avoid locations subject to direct sunlight and maintain normal temperature, humidity, and pressure conditions. The allowable specifications for environments suitable for usage, storage, and transportation are given below. 1) Temperature: The allowable temperature range differs for each relay, so refer to the relay's individual specifications. In addition, when transporting or storing relays while they are tube packaged, there are cases when the temperature may differ from the allowable range. In this situation, be sure to consult the individual specifications. 2) Humidity: 5 to 85% RH The humidity range varies with the temperature. Use within the range indicated in the graph. ( The allowable temperature depends on the relays. ) ● Condensation Condensation occurs when the ambient temperature drops suddenly from a high temperature and humidity, or the relay and microwave device is suddenly transferred from a low ambient temperature to a high temperature and humidity. Condensation causes the failures like insulation deterioration, wire disconnection and rust etc. Panasonic Industry Co., Ltd. does not guarantee the failures caused by condensation. The heat conduction by the equipment may accelerate the cooling of device itself, and the condensation may occur. Please conduct product evaluations in the worst condition of the actual usage. ( Special attention should be paid when high temperature heating parts are close to the device. Also please consider the condensation may occur inside of the device. ) Humidity (% RH) ● Icing Condensation or other moisture may freeze on relays when the temperature become lower than 0 ℃. This icing causes the sticking of movable portion, the operation delay and the contact conduction failure etc. Panasonic Industry Co., Ltd. does not guarantee the failures caused by the icing. The heat conduction by the equipment may accelerate the cooling of relay itself and the icing may occur. Please conduct product evaluations in the worst condition of the actual usage. 85 Allowable range Avoid icing when used at temperatures lower than 0°C Avoid condensation when used at temperatures higher than 0°C 5 -40 0 85 Ambient temperature (℃) 3) Pressure: 86 to 106 kPa ● Low temperature and low humidity The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. ● High temperature and high humidity Storage for extended periods of time ( including transportation periods ) at high temperature or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported. ● Package In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 10 ー Panasonic Industry Co., Ltd. 2022 ASCTB414E 202210 GUIDELINES FOR SIGNAL RELAYS USAGE ● Storage requirements Since the surface-mount terminal type is sensitive to humidity it is packaged with tightly sealed anti-humidity packaging. However, when storing, please be careful of the following. 1) Please use promptly once the anti-humidity pack is opened. ( within 72 hours, Max. 30 ℃ / 70% RH ). If left with the pack open, the relay will absorb moisture which will cause thermal stress when reflow mounting and thus cause the case to expand. As a result, the seal may break. 2) If relays will not be used within 72 hours, please store relays in a humidity controlled desiccator or in an antihumidity bag to which silica gel has been added. 4 ) The following cautionary label is affixed to the antihumidity pack. * If the relay is to be soldered after it has been exposed to excessive humidity atmosphere, cracks and leaks can occur. Be sure to mount the relay under the required mounting conditions. 3) When relays ( which is packaged with humidity indicator and silica gel ) meeting one of below criteria, please bake ( dry ) before use. • When the storage conditions specified in 1) are exceeded. • When humidity indicator is in Ⅲ or Ⅳ status according to judgement standard. Please check humidity indicator color and decide if baking is necessary or not. ●: indicate brown, ○: Other than brown ( blueish color ) 5% 10% 60% Bake treatment necessity judgment Ⅰ ● ● ● No need to bake Ⅱ ○ ● ● No need to bake Ⅲ ○ ○ ● Need to bake Ⅳ ○ ○ ○ Need to bake Spot 5% 10% ● Silicon When a source of silicone substances ( silicone rubber, silicone oil,silicone coating materials and silicone filling materials etc. ) is used around the relay, the silicone gas ( low molecular siloxane etc. ) may be produced This silicone gas may penetrate into the inside of the relay. When the relay is kept and used in this condition, silicone compound may adhere to the relay contacts which may cause the contact failure. Do not use any sources of silicone gas around the relay ( Including plastic seal types ). ● NOx Generation When relay is used in an atmosphere high in humidity to switch a load which easily produces an arc, the NOx created by the arc and the water absorbed from outside the relay combine to produce nitric acid. This corrodes the internal metal parts and adversely affects operation. Avoid use at an ambient humidity of 85 % RH or higher ( at 20 ℃ ). If use at high humidity is unavoidable, please contact our sales representative. 60% Humidity indicator card <Baking ( Drying ) conditions> • With reel : 45 ℃, 96 hours or more. • Without reel ( including relay only ): 60 ℃, 35 hours or more. Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 11 ー Panasonic Industry Co., Ltd. 2022 ASCTB414E 202210 GUIDELINES FOR SIGNAL RELAYS USAGE OTHERS ■ Cleaning • Although the environmentally sealed type relay (plastic sealed type,etc. ) can be cleaned, avoid immersing the relay into cold liquid ( such as cleaning solvent ) immediately after soldering. Doing so may deteriorate the sealing performance. • Surface-mount terminal type relay is sealed type and it can be cleaned by immersion. Use pure water or alcohol-based cleaning solvent. • Cleaning with the boiling method is recommended ( The temperature of cleaning liquid should be 40℃ or lower ). Avoid ultrasonic cleaning on relays. Use of ultrasonic cleaning may cause breaks in the coil or slight sticking of the contacts due to the ultrasonic energy. Please refer to "the latest product specifications" when designing your product. •Requests to customers: https://industrial.panasonic.com/ac/e/salespolicies/ Panasonic Industry Co., Ltd. Electromechanical Control Business Division industrial.panasonic.com/ac/e/ ー 12 ー Panasonic Industry Co., Ltd. 2022 ASCTB414E 202210 ■ Global Sales Network Information: industrial.panasonic.com/ac/e/salesnetwork Electromechanical Control Business Division 1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan industrial.panasonic.com/ac/e/ ©Panasonic Industry Co., Ltd. 2022 Specifications are subject to change without notice. モヴヤヵャピヘブユチチチビパビビヒパ 2022.10
AGQ20TS2HZ 价格&库存

很抱歉,暂时无法提供与“AGQ20TS2HZ”相匹配的价格&库存,您可以联系我们找货

免费人工找货