GU 2 Form B (AQW414)
Normally closed
DIP8-pin type
of 400V load voltage
9.78
.385
6.4
.252
3.9
.154
GU 2 Form B
(AQW414)
FEATURES
TYPICAL APPLICATIONS
1. Approx. 1/2 the space compared
with the mounting of Two 1 Form B
PhotoMOS units
• High-speed inspection machines
• Telephone equipment
• Computers
6.4
.252
9.78
.385
3.6
.142
Two 1 Form B units
2 Form B type
mm inch
1
8
2
7
3
6
4
5
2. Applicable for 2 Form B use as well
as two independent 1 Form B use
3. Controls load currents up to 0.13 A
with an input current of 5 mA
4. High speed switching: operate time
typ. 0.46 ms
5. Extremely low closed-circuit offset
voltages to enable control of small
analog signals without distortion
RoHS compliant
TYPES
Output rating*
AC/DC
dual use
Part No.
Load
voltage
Load
current
Package
400 V
100 mA
DIP8-pin
Through hole
terminal
Tape and reel packing style
Picked from the
Picked from the
1/2/3-pin side
4/5/6-pin side
Tube packing style
AQW414
Packing quantity
Surface-mount terminal
AQW414A
AQW414AX
AQW414AZ
Tube
Tape and reel
1 tube contains:
50 pcs.
1 batch contains:
500 pcs.
1,000 pcs
*Indicate the peak AC and DC values.
Note: The surface mount terminal shape indicator “A” and the packing style indicator “X” or “Z” are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Input
Output
Item
LED forward current
LED reverse voltage
Peak forward current
Power dissipation
Load voltage (peak AC)
Symbol
IF
VR
IFP
Pin
VL
AQW414(A)
50 mA
5V
1A
75 mW
400 V
Continuous load current
IL
0.1 A (0.13 A)
0.3 A
800 mW
850 mW
1,500 V AC
Operating
Ipeak
Pout
PT
Viso
Topr
Storage
Tstag
Peak load current
Power dissipation
Total power dissipation
I/O isolation voltage
Temperature limits
Panasonic Corporation
–40°C to +85°C –40°F to +185°F
–40°C to +100°C –40°F to +212°F
Automation Controls Business Unit
Remarks
f = 100 Hz, Duty factor = 0.1%
Peak AC, DC
( ): in case of using only 1 channel
100 ms (1 shot), VL = DC
Non-condensing at low temperatures
industrial.panasonic.com/ac/e
ASCTB51E 201201-T
GU 2 Form B (AQW414)
2. Electrical characteristics (Ambient temperature: 25°C 77°F)
Item
Symbol
LED operate (OFF) current
Input
LED reverse (ON) current
LED dropout voltage
Typical
Maximum
Minimum
Typical
Typical
Maximum
AQW414(A)
0.7 mA
3 mA
0.4 mA
0.64 mA
1.25 V (1.14 V at IF = 5 mA)
1.5 V
IFoff
IFon
VF
Ron
Off state leakage current
Maximum
Operate (OFF) time*
Transfer
characteristics
Reverse (ON) time*
I/O capacitance
Initial I/O isolation resistance
IF = 50 mA
IF = 0 mA
IL= Max.
Within 1 s on time
IF = 5 mA
VL = Max.
1 µA
ILeak
Typical
Maximum
Typical
Maximum
Typical
Maximum
Minimum
IL = Max.
50 Ω
Maximum
Output
IL = Max.
26 Ω
Typical
On resistance
Condition
IF = 0 mA ➝ 5 mA
IL = Max.
0.46 ms
Toff
1 ms
0.40 ms
Ton
IF = 5 mA ➝ 0 mA
IL = Max.
1 ms
0.8 pF
Ciso
f = 1 MHz
VB = 0 V
1.5 pF
1,000 MΩ
Riso
500 V DC
*Operate/Reverse time
Input
Output
10%
90%
Toff
Ton
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper device operation and resetting.
Item
Input LED current
Symbol
IF
Recommended value
Unit
5
mA
■ For Dimensions.
■ For Schematic and Wiring Diagrams.
■ For Cautions for Use.
■ These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation
technical representative.
For more information.
REFERENCE DATA
1. Load current vs. ambient temperature
characteristics
2. On resistance vs. ambient temperature
characteristics
3. Operate (OFF) time vs. ambient temperature
characteristics
Allowable ambient temperature: –40°C to +85°C
–40°F to +185°F
Measured portion: between terminals 5 and 6, 7 and 8;
LED current: 0 mA;
Continuous load current: 100 mA (DC)
LED current: 5 mA;
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
50
Using 2 channels
On resistance, Ω
Load current, mA
120
100
1.2
60
Using only 1 channel
Operate (OFF) time, ms
140
80
60
30
20
40
–20
0
20
40
60
8085 100
Ambient temperature, °C
ASCTB51E 201201-T
0
Panasonic Corporation
0.8
0.6
0.4
0.2
10
20
0
–40
40
1.0
–40
–20
0
20
40
60
8085
Ambient temperature, °C
Automation Controls Business Unit
0
–40
–20
0
20
40
60 8085
Ambient temperature, °C
industrial.panasonic.com/ac/e
GU 2 Form B (AQW414)
4. Reverse (ON) time vs. ambient temperature
characteristics
5. LED operate (OFF) current vs. ambient
temperature characteristics
6. LED reverse (ON) current vs. ambient
temperature characteristics
LED current: 5 mA; Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC)
1.0
0.8
0.6
0.4
5
4
3
2
1
0.2
0
5
LED reverse (ON) current, mA
LED operate (OFF) current, mA
Reverse (ON) time, ms
1.2
–40
–20
0
0
20
40
60 8085
Ambient temperature, °C
4
3
2
1
–40
–20
0
20
40
60
0
8085
–40
–20
Ambient temperature, °C
0
20
40
60 8085
Ambient temperature, °C
7. LED dropout voltage vs. ambient
temperature characteristics
8. Current vs. voltage characteristics of output
at MOS portion
9. Off state leakage current vs. load voltage
characteristics
LED current: 5 to 50 mA
Measured portion: between terminals 5 and 6, 7 and 8;
Ambient temperature: 25°C 77°F
Measured portion: between terminals 5 and 6, 7 and 8;
Ambient temperature: 25°C 77°F
1.4
50mA
30mA
1.3 20mA
10mA
1.2 5mA
100
80
60
40
20
–6 –5 –4 –3 –2 –1
1 2 3 4 5 6
–20
Voltage, V
–40
1.1
Off state leakage current, A
120
Current, mA
LED dropout voltage, V
1.5
10 –3
10 –6
10 –9
–60
1.0
–80
10 –12
–100
0
–40 –20
–120
0
20 40 60 8085 100
Ambient temperature, °C
0
20
60
40
80
Load voltage, V
100
10. Operate (OFF) time vs. LED forward
current characteristics
11. Reverse (ON) time vs. LED forward current
characteristics
12. Output capacitance vs. applied voltage
characteristics
Measured portion: between terminals 5 and 6, 7 and 8;
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC);
Ambient temperature: 25°C 77°F
Measured portion: between terminals 5 and 6, 7 and 8;
Load voltage: 400 V (DC);
Continuous load current: 100 mA (DC);
Ambient temperature: 25°C 77°F
Measured portion: between terminals 5 and 6, 7 and 8;
Frequency: 1 MHz;
Ambient temperature: 25°C 77°F
2.0
1.5
1.0
Output capacitance, pF
Reverse (ON) time, ms
Operate (OFF) time, ms
2.5
1.0
0.8
0.6
0.4
10
20
30
40
50
LED forward current, mA
Panasonic Corporation
60
0
100
80
60
40
20
0.2
0.5
0
120
1.2
3.0
10
20
30
40
50
LED forward current, mA
Automation Controls Business Unit
60
0
0
10
industrial.panasonic.com/ac/e
20
30
40
50
60
Applied voltage, V
ASCTB51E 201201-T
很抱歉,暂时无法提供与“AQW414”相匹配的价格&库存,您可以联系我们找货
免费人工找货