Varistors (ZNR Surge Absorber) Type SMD
Varistors (ZNR Surge Absorber)
Type: SMD
Series: HF
Features
●
●
●
●
●
●
●
●
Meet for Load Dump Surge Test (JASO D 001-94) [Vp=70 V,τ=200 ms,Ri=0.8 Ω]
Meet for Load Dump Surge Test ISO7637-2 and ISO16750-2
Suitable for requirements of Automotive
Compact size SMD
Meet flow/reflow/iron soldering
Strong against “Soldering heat shock” due to molded construction
AEC-Q200 compliant
RoHS compliant
Recommended Applications
● Protection of Body & Accessory ECU about DC12 V automotive against Load Dump Surge
■ As for Handling Precautions and Minimum Quantity / Packing Unit
Please see Related Information.
Explanation of Part Numbers
1T ERJS02 ~ ERJS1Tシリーズ
1
2
3
4
5
6
7
8
9
10
11
E
R
Z
H
F
2
M
2
2
0
D
Product Code
Construction
Series
Nominal
12
Design No.
Varistor Voltage
Embossed Taping
Construction
①
②
① Multilayer Varistor
ZnO, others
② Mold Resin
Epoxy (UL94 V-0 approved)
③ Lead Terminal
Sn plated Ni-Fe alloy
③
Dimensions in mm (not to scale)
H
Part No.
S
S
L
E
W
ERZHF2M220D
ERZHF2M270
W
L
Dimensions(mm)
H
S
6.4±0.4 8.0±0.5
5.5±0.5
4.5±0.5
E
1.3±0.3 2.5±0.2
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
14-Dec-20
Varistors (ZNR Surge Absorber) Type SMD
Ratings and Characteristics
● Operating Temperature Range
● Storage Temperature Range
Part No.
: ‒40 to 125 ℃
: ‒40 to 125 ℃
Varistor Voltage
Maximum
Allowable Voltage
Short Time
Over-voltage
Clamping
Voltage
V1 mA (V)
DC (V)
DC (V)
(V) at Ip 5(A)
16
24
5 min.
35 max.
ERZHF2M220D
20 to 23.2
ERZHF2M270
27±20 %
Load Dump Surge
JASO
Category:A, A-1
70 V, 1time
43 max.
Marking Contents
②
①Z N R
H F 2 2 0
◆◇●
① Product name
ZNR Surge Absorbers
② Abbreviation of P/N
HF220 (ERZHF2M220D), HF270 (ERZHF2M270)
◆✽ Yearly
③
2019:9, 2020:K, 2021:A, 2022:B, 2023:C, 2024:D
Jan.:1, Feb.:2, Mar.:3, Apr.:4, May:5, Jun.:6,
Jul.:7, Aug.:8, Sep.:9, Oct.:O, Nov.:N, Dec.:D
③ Date Code ◇ Monthly
● 10 Days 1st to 10th:1, 11th to 20th:2, 21st to 31st:3
✽ If the 10's digit of a Christian year is an even year, as an end abbreviation, an alphabetic
character is used.
1:A, 2:B, 3:C, 4:D, 5:E, 6:F, 7:G, 8:H, 9:J, 0:K
If the 10's digit of a Christian year is an odd year, as an end abbreviation, a number is used.
Packaging Methods
Embossed Taping
Part No.
ERZHF2M220D
ERZHF2M270
● Embossed Taping
1,000 pcs / reel
t1
Width of Tape :16 mm
Quantity
800 pcs / reel
Chip pocket
Feeding hole
øD0
P0
W
B
F
P2
E
● Packing Quantity
Style
A
t2
Part No.
ERZHF2M220D
ERZHF2M270
A
P1
Chip component
B
W
7.5 max. 11.9 max. 16.0±0.3
F
E
Direction of feed
P1
7.5±0.1 1.75±0.10 12.0±0.1
P2
2.0±0.1
P0
øD0
4.0±0.1 1.5+0.1/0
t1
Unit : mm
t2
0.8 max.
9.0 max.
8.0 max.
● Reel
T
r
C
B
E
øD
A
Part No.
t
W
ERZHF2M
A
382 max.
B
50 min.
C
13.0±0.5
øD
21.0±0.8
W
T
t
r
16.4+2.0/0
22.4 max.
2.5±0.5
1.0
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Unit : mm
E
2.0±0.5
14-Dec-20
Varistors (ZNR Surge Absorber) Type SMD
Performance Characteristics
Characteristics
Test Methods
Specifications
Standard Test
Condition
Environmental conditions under which every measuring is done without
doubt on the measuring results. Unless specially, specified, temperature,
relative humidity are 5 °C to 35 °C, 45 to 85% RH respectively.
Maximum Allowable
Voltage
The maximum DC voltage that can be applied continuously in the
specified environmental temperature range.
Short Time OverVoltage
The maximum DC Voltage that can be applied specified period without
breakdown.
Varistor Voltage
Voltage between both terminals of ZNR measured when 1 mA of DC
current is applied under standard conditions. It is called V1. Measuring
the varistor voltage should be made promptly to avoid heat affection.
Clamping Voltage
The maximum voltage between two terminals with the specified impulse
current (8/20 μs).
-
To meet the
specifi ed value.
The test waveform of transient voltage which specified JASO Category
A A-1 70 V without breakdown.
Load Dump Surge
Vp=70 V
No breakdown.
36.8 %
PS Voltage
0V
τ=200 ms
※ Please Check Specification of the products about Mechanical & Environmental etc. requirements.
Recommendation Land Size
Land
8.0
6.4
3.0
Product
Occupied Space
5.0
10.0
Unit : mm
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
14-Dec-20
*XLGHOLQHVDQGSUHFDXWLRQVUHJDUGLQJWKH
WHFKQLFDOLQIRUPDWLRQDQGXVHRIRXUSURGXFWV
GHVFULEHGLQWKLVRQOLQHFDWDORJ
ٹ,I\RXZDQWWRXVHRXUSURGXFWVGHVFULEHGLQWKLVRQOLQHFDWDORJIRUDSSOLFDWLRQVUHTXLULQJ
VSHFLDOTXDOLWLHVRUUHOLDELOLW\RUIRUDSSOLFDWLRQVZKHUHWKHIDLOXUHRUPDOIXQFWLRQRIWKH
SURGXFWVPD\GLUHFWO\MHRSDUGL]HKXPDQOLIHRUSRWHQWLDOO\FDXVHSHUVRQDOLQMXU\
HJDLUFUDIWDQGDHURVSDFHHTXLSPHQWWUDIILFDQGWUDQVSRUWDWLRQHTXLSPHQWFRPEXVWLRQ
HTXLSPHQWPHGLFDOHTXLSPHQWDFFLGHQWSUHYHQWLRQDQWLFULPHHTXLSPHQWDQGRUVDIHW\
HTXLSPHQWLWLVQHFHVVDU\WRYHULI\ZKHWKHUWKHVSHFLILFDWLRQVRIRXUSURGXFWVILWWRVXFK
DSSOLFDWLRQV3OHDVHHQVXUHWKDW\RXZLOODVNDQGFKHFNZLWKRXULQTXLU\GHVNDVWRZKHWKHU
WKHVSHFLILFDWLRQVRIRXUSURGXFWVILWWRVXFKDSSOLFDWLRQVXVHEHIRUH\RXXVHRXUSURGXFWV
ٹ7KHTXDOLW\DQGSHUIRUPDQFHRIRXUSURGXFWVDVGHVFULEHGLQWKLVRQOLQHFDWDORJRQO\DSSO\
WRRXUSURGXFWVZKHQXVHGLQLVRODWLRQ7KHUHIRUHSOHDVHHQVXUH\RXHYDOXDWHDQGYHULI\
RXUSURGXFWVXQGHUWKHVSHFLILFFLUFXPVWDQFHVLQZKLFKRXUSURGXFWVDUHDVVHPEOHGLQ\RXU
RZQSURGXFWVDQGLQZKLFKRXUSURGXFWVZLOODFWXDOO\EHXVHG
ٹ,I\RXXVHRXUSURGXFWVLQHTXLSPHQWWKDWUHTXLUHVDKLJKGHJUHHRIUHOLDELOLW\UHJDUGOHVV
RIWKHDSSOLFDWLRQLWLVUHFRPPHQGHGWKDW\RXVHWXSSURWHFWLRQFLUFXLWVDQGUHGXQGDQF\
FLUFXLWVLQRUGHUWRHQVXUHVDIHW\RI\RXUHTXLSPHQW
ٹ7KHSURGXFWVDQGSURGXFWVSHFLILFDWLRQVGHVFULEHGLQWKLVRQOLQHFDWDORJDUHVXEMHFWWR
FKDQJHIRULPSURYHPHQWZLWKRXWSULRUQRWLFH7KHUHIRUHSOHDVHEHVXUHWRUHTXHVWDQG
FRQILUPWKHODWHVWSURGXFWVSHFLILFDWLRQVZKLFKH[SODLQWKHVSHFLILFDWLRQVRIRXUSURGXFWVLQ
GHWDLOEHIRUH\RXILQDOL]HWKHGHVLJQRI\RXUDSSOLFDWLRQVSXUFKDVHRUXVHRXUSURGXFWV
ٹ7KHWHFKQLFDOLQIRUPDWLRQLQWKLVRQOLQHFDWDORJSURYLGHVH[DPSOHVRIRXUSURGXFWV
W\SLFDORSHUDWLRQVDQGDSSOLFDWLRQFLUFXLWV:HGRQRWJXDUDQWHHWKHQRQLQIULQJHPHQWRI
WKLUGSDUW\
VLQWHOOHFWXDOSURSHUW\ULJKWVDQGZHGRQRWJUDQWDQ\OLFHQVHULJKWRULQWHUHVW
LQRXULQWHOOHFWXDOSURSHUW\
ٹ,IDQ\RIRXUSURGXFWVSURGXFWVSHFLILFDWLRQVDQGRUWHFKQLFDOLQIRUPDWLRQLQWKLVRQOLQH
FDWDORJLVWREHH[SRUWHGRUSURYLGHGWRQRQUHVLGHQWVWKHODZVDQGUHJXODWLRQVRIWKH
H[SRUWLQJFRXQWU\HVSHFLDOO\ZLWKUHJDUGWRVHFXULW\DQGH[SRUWFRQWUROVKDOOEHREVHUYHG
5HJDUGLQJWKH&HUWLILFDWHRI&RPSOLDQFHZLWK
WKH(85R+6'LUHFWLYH5($&+5HJXODWLRQV!
ٹ7KHVZLWFKRYHUGDWHIRUFRPSOLDQFHZLWKWKH5R+6'LUHFWLYH5($&+5HJXODWLRQVYDULHV
GHSHQGLQJRQWKHSDUWQXPEHURUVHULHVRIRXUSURGXFWV
ٹ:KHQ\RXXVHWKHLQYHQWRU\RIRXUSURGXFWVIRUZKLFKLWLVXQFOHDUZKHWKHUWKRVHSURGXFWV
DUHFRPSOLDQWZLWKWKH5R+6'LUHFWLYH5($&+5HJXODWLRQSOHDVHVHOHFW6DOHV,QTXLU\LQWKH
ZHEVLWHLQTXLU\IRUPDQGFRQWDFWXV
:HGRQRWWDNHDQ\UHVSRQVLELOLW\IRUWKHXVHRIRXUSURGXFWVRXWVLGHWKHVFRSHRIWKH
VSHFLILFDWLRQVGHVFULSWLRQVJXLGHOLQHVDQGSUHFDXWLRQVGHVFULEHGLQWKLVRQOLQHFDWDORJ
$SU
Varistors (ZNR Surge Absorber)
Varistors (ZNR Surge Absorber) Type D, Series V
Varistors (ZNR Surge Absorber) Type SMD, Series HF, VF
Handling Precautions
Safety Precautions
In case that a Varistors (ZNR Surge Absorber) (hereafter referred to as the ZNR, or product name) is used,
if an abnormality takes place because of peripheral conditions of the ZNR(material, environments, power
source conditions, circuit conditions, etc. in equipment design), fire, electric shock, burn, or product failure
may be occur. The precautions for this product are described below, understand the content thoroughly
before usage. For more questions, contact us.
If there's any uncertainty/doubt/products safety items, please contact us. When a dogma shall be occurred
about safety for this products, be sure to inform us rapidly, operate your technical examination.
1.
Precautions to be strictly observed
1.1 Confirmation of performance ratings
Use the ZNR within its rated range of performance such as the Max. allowable voltage, withstanding surge
current, withstanding energy, impulse life(surge life), average pulse power, and operating temperature range.
If used outside the range, the ZNR can be degrade and have element fracture, which may result in smoking
and ignition.
1.2 To avoid accidents due to unexpected phenomena, take the following measures
1) In the event of fracture of the ZNR, its pieces may scatter ; hence, put the case or cover of the set product
in place.
2) Do not install the ZNR near combustible substances(polyvinyl chloride wires, resin moldings, etc.).
If it is difficult to do, install a nonflammable cover.
3) Across-the-line use
When the ZNR is used across a line, put a current fuse in series with the ZNR(Refer to Item 2.1.1). (4) .
4) Use between line to ground
(1) If the case that the ZNR is used between a line to the ground, the short-circuit of the ZNR may not
blow the current fuse because of grounding resistance, which may cause smoking and ignition of the
ZNR’s exterior resin.
As the measure against it, install an earth leakage breaker on the power supply side of the ZNR
position. If no earth leakage breaker is installed, use a thermal fuse together wth a current fuse in
series. (Refer to Table 1.)
(2) If the case that the ZNR is used between a live part to metal case, an electric shock may develop at a
shortcircuit of the ZNR ; hence, ground the metal case to the ground or keep it from the human body.
1.3 If ZNR is shorted out and happen smoke or ignition, please cut provided current to ZNR immediately.
2. Application notes
2.1 Pay attention to the following items to avoid the shortened life and failure of the ZNR
1) Circuit conditions
(1) Select a ZNR of which the maximum voltage including fluctuations in source voltage allows for the
maximum permissible circuit voltage. (Refer to Table 1.)
(2) In cases that surges are intermittently applied at short intervals(for example, in case that the voltage
of the noise simulator test is implemented etc.), do not let them exceed the ZNR’s rated power.
(3) Select a ZNR recommended in Table 1.
Across-the-line use
If possible, use a Part No. marked with * in case of voltage temporarily rises load unbalance of
separately-wired loads, short between hot and neutral-line, open of neutral line in
single-phase-three-wired system, and due to resonance at switching for a capacitive, inductive load.
14-Dec-20
Varistors (ZNR Surge Absorber)
Used between line to ground
Use a different Part No. from “Across-the-line use” as table 1, because of raising voltage in case of
“Line to Ground Fault”.
Use a Part No. marked with ** in table 1, in case of the insulation resistance test(500 VDC) for
equipment. When using a Part of the varistor voltage that the insulation efficiency examination can
not be cleared, there is a case where the surge absorber can be done by removing it from the circuit
depending on the circuit condition(Refer examination of Japan Domestic Safety Regulations).
Use a Part No. marked with *** in table 1, in case of the withstanding voltage test
(1000 VAC or 1200 VAC) for equipment.
(4) Concerning current fuse
We recommend selecting a ZNR and the rated current of a current fuse as follows.
Finally, please be sure that there is no danger if the ZNR mounted on the equipment breaks.
●Type D, Series V
Standard
ERZV05D□□□ ERZV07D□□□ ERZV09D□□□ ERZV10D□□□ ERZV14D□□□ ERZV20D□□□
Part No.
Fuse rated
10 A max.
10 A max.
3 A max.
5 A max.
7 A max.
7 A max.
current
◆ Fuses shall use rated voltages ap pro pri ate for circuits.
●Type SMD, Series VF
Standard
ERZVF□M□□□
Part No.
Fuse rated
5 A max.
current
◆ Fuses shall use rated voltages ap pro pri ate for circuits.
◆ Concerning HF series, please confirm adjusted to load dump surge and protection cooperation.
The recommended fuse position is shown in table 1, “Example of ZNR application”, however, if the
load current of protected equipment is larger than that of the above recommended fuse rated current,
install a current fuse at the position shown below.
Current Fuse
Power Source Side
Protected
Equipmen
ZNR
(5) Concerning thermal fuse
Set a thermal fuse to get high thermal
14-Dec-20
Varistors (ZNR Surge Absorber)
Table 1 Example of ZNR application
DC/AC
Single-phase
Across-the-Line use
Connections example
fuse
Use between Line to ground
DC/AC
Single-phase
fuse
ZNR1
L
L
Protected
Equipmen
N
ZNR1
Protected
Equipme
Equipmen
N
ZNR2
Thermal coupling
AC 3-phase
Thermal Fuse
AC 3-phase
fuse
fuse
ZNR3
ZNR3
ZNR3
ZNR3
Protected
Protected
Protected
Equipme
Equipmen
Equipme
ZNR4
Example of varistor voltage
ZNR3
ZNR
ZNR 1
ZNR 3
Source
voltage
AC 100 V
AC 120 V
AC 200 V
AC 220 V
AC 240 V
AC 380 V
Nominai varistor voltage
SMD Mold Type
Type D
201 to 361* 201 to 361*
241 to 431* 241 to 431*
471 to 621*
471
471 to 621*
471
511, 621*
821
-
Thermal coupling
Thermal Fuse
Source
voltage
Nominai varistor voltage
SMD Mold Type
Type D
471
471
AC 100 V
511
AC 220 V
621*
821 and more**
182***
ZNR 2
511
ZNR 4
AC 230 V
621*
AC 240 V
821 and more**
182***
112**
AC 380 V
182***
Note : Element size is selected by impulse Condition.
ZNR
(6) On use for equipment
The catalog guarantees the quality as individual component.
Before you use the products, please make sure to check and evaluate the products in
the circumstance where they are installed in your product.
2) Operating environments
(1) The ZNR is designed to be used indoors. Do not use it exposed outdoors.
(2) Do not use the ZNR in places exposed to temperatures beyond the operating temperature range, such
as places exposed to sunlight and vicinities of heating equipment.
(3) Do not use the ZNR in places exposed to high temperatures and high humidity, such as places exposed
directly to rain, wind, dew condensation, and vapor.
(4) Do not use the ZNR in dusty and salinity environment and atmospheres polluted by corrosive gases,
in liquids such as water, oil, chemical, organic solvent.
3) Processing conditions
(1) Do not wash the ZNR by such solvents(thinner, acetone, etc.) as its exterior resin deteriorates.
(2) Do not apply a strong vibration or shock (by falling, etc.) to the ZNR, cracking to its exterior resin
and element may occur.
(3) When coating the ZNR with resin(including molding), do not use such resin.
(4) Do not bend the ZNR type D lead wires at the position close to its ZNR type D exterior resin, or apply
external force to the position.
(5) When soldering the ZNR lead wires, follow the recommended conditions and do not melt the solder
and insulating materials constituting the ZNR.
14-Dec-20
Varistors (ZNR Surge Absorber)
Soldering Method
260
10
260
10
Flow soldering
Type D
Flow soldering
SMD
Type
Reflow soldering
Attention Item
Recommended Condition
°C, within
seconds.
°C, within
seconds.
Type D is not Refl ow soldering object part.
When the package density of the part is high pill out gas
because the solderability sometimes becomes bad.
When Land is too big compared with the size of the
Refer to Reflow
soldering profile
terminal surface of the part, be careful because the part
sometimes upset when solder fuses.
* 1 Soldering iron temperature should not exceed 400 °C and should not be applied for mor than 5 seconds.
* 2 Profile be careful because there is a margin of error in the way of measuring.
* 3 The temperature depend on the size and the package density of the substrate.
Therefore, confirm every kind of the substrate.
The limits of resistance to
●Soldering temperature-time profile to recommend
reflow solderling heat
260
Gradual cooling
Temperature (°C)
Preheating
Temperature (°C)
Reflow soldering
Soldering
Rising
temp.
(Ⅰ)
Soldering
Gradual cooling
Gradual
Preheating
cooling
Rising
temp.
Main heating
240
230
220
210
200
(Ⅱ)
Time
Preheating
250
Temperature (°C)
Flow soldering
Time
The normal to 130 °C max. 120 s
max. 260 °C
max. 10 s
Gradual cooling
Rising temperature I
Preheating
Rising temperature II
Main heating
Gradual cooling
0
10
20
30
40
50
60
Time (s)
The normal to preheating temperature
150 ℃ to 180 ℃
Preheating to 200 ℃
30 to 60 s
60 to 120 s
2 to 6 ℃ / s
(cf. The limit of resistance to refl ow soldering heat)
200 ℃ to 100 ℃
1 to 4 ℃ / s
(Reflow soldering shall be within two times)
(6) Lead-wire terminal land-hole (only for Type D)
When designing lead-wire-terminal land-hole of circuit board, please check actual ZNR by
reference specification about center value of lead-wire terminal pitch.
(7) Mounting (only for Type SMD)
In case of mounting ZNR on a Printed Circuit Board, be careful not to put excessive impact load, such as
pressure from adsorption nozzle, and mechanical impact/stress of position-shifting or positioning.
Also, we recommend you to fix a Printed Circuit Board to sheathing resin with an adhesive in case of
position-shifting of ZNR when mounting.
4) Long-term storage
(1) Do not store the ZNR under high temperature and high humidity. Store it indoor environment at a
temperature up to 40 °C and at humidity below 75 %RH, and use it within two years.
Before using the ZNR that has been stored for a long period(two years or longer), confirm the solderability.
(2) Avoid atmospheres full of corrosive gases (hydrogen sulfide, sulfurous acid, chlorine, ammonia, etc.).
(3) Avoid direct sunlight and dew condensation.
5) Rated Voltage for UL or other safety certifications
Our ZNR define “ Max. Allowable Voltage” and “Rated Voltage “ to keep leakage current specification and
others. If you getting certificate of safety approval about your equipment with our ZNR, please follow our
“Rated Voltage”.
14-Dec-20
Varistors (ZNR Surge Absorber)
6) Dropped product
Do not drop this product on the floor. If this product is dropped, it can be damaged mechanically or
electrically. Avoid using the dropped product.
3. Notices
3.1 Our ZNR was designed and manufactured for standard applications such as general electronics devices,
office equipment, information and communications equipment, measuring instruments, household
appliances and audio-video equipment.For applications in which special quality and reliability are required,
or if the failure or malfunction of the products may directly jeopardize life or cause threat of personal injury
(such as for aircraft and aerospace equipment, traffic and transport equipment, combustion equipment,
medical equipment, accident prevention and anti-theft devices, and safety equipment), please be sure to
consult with our sales representative in advance and to exchange product specifications which conform to
such applications. applications in which special quality and reliability are required, or if the failure or
malfunction of the products may.
3.2 Note that we do not take any responsibility for faults and abnormalities resulting from the use not in
conformity with the contents of entries in the delivery specification.
3.3 There is a possibility that the ZNR will unexpectedly cause smoke or ignite because of an abnormal rise of
the circuit voltage and invasion of excessive surge. To prevent that accident from spreading over the
equipment and not to expand the damage, use multiplex protection such as the adoption of frameretardant materials for housing parts and structural parts.
4. Applicable laws and regulations , others
4.1 This product not been manufactured with any ozone depleting chemical controlled under the Montreal
Protocol.
4.2 This product comply with RoHS(Restriction of the use of certain Hazardous Substance in electrical and
electronic equipment) (DIRECTIVE 2011/65/EU and (EU)2015/863).
4.3 All the materials used in this part are registered material under the Law Concerning the Examination and
Regulationof Manufacture, etc. of Chemical Substance.
4.4 If you need the notice by letter of “A preliminary judgement on the Laws of Japan foreign exchange and
Foreign Trade Control”, be sure to let us know.
4.5 These products are not dangerous goods on the transportation as identified by UN(United nations) numbers
or UN classification.
5. Others
5.1 As to the disposal of ZNR, check the method of disposal in each country or origin where the ZNR are
incorporated in your products to be used.
5.2 The technical information in this specification provides example of our products’ typical operations and
application circuit. We do not guarantee the non-infringement of third party’s intellectual property rights
and we do not grant any license, right or interest in our intellectual property.
6. AEC-Q200 Compliant (Type SMD, Series HF)
The products are tested based on all or part of the test conditions and methods defined in AEC-Q200.
Please consult with Panasonic for the details of the product specification and specific evaluation test results,
etc., and please review and approve Panasonic's product specification before ordering.
14-Dec-20