0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FX-101

FX-101

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR NPN OUTPUT 12-24VDC

  • 数据手册
  • 价格&库存
FX-101 数据手册
157 FIBER SENSORS Digital Fiber Sensor FX-100 SERIES Related Information ■■General terms and conditions............ F-17 ■■Glossary of terms / General precautions........ P.1359~ / P.1405 ■■Sensor selection guide....................... P.3~ ■■Fiber selection.................................... P.5~ LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Conforming to EMC Directive Listing AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS FX-100 series has been modificated from July 2011 production. The color of enclosure has been changed from white to dark gray and the protection cover has been attached. PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic-electric-works.net/sunx PNP output type available Timer Automatic sensitivity setting Test input Interference Light intensity monitor prevention STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Taking fiber sensors to the next level Setup is made simple, using a dual digital display The dual digital display allows users to check both the threshold value and incident light intensity at the same time, allowing for clear and intuitive control of the sensor’s functions. Threshold value Incident light intensity FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 Commercially-available connectors are used so that lead time and spare part numbers can both be reduced The connectors used are commercially-available connectors, so that processing costs and lead time required for carrying out processing after purchase of the sensors can be greatly reduced. The same connection parts as the DP-100 series of digital pressure sensors and the PM-64 series of micro photoelectric sensors can be used. Commercially-available press-fit connectors are used, so that the processing costs for connection cables can be greatly reduced. Conventional (cable type) FX-311 FX-301-F7/ FX-301-F Conventional lead time ● Harness processing by outside order is needed after sensor preparation. FX-300 FX-410 Commercially-available connector Customer Sensor preparation Sensor purchase and preparation Harness processing by outside order Sensor installation Harness processor From now on (built-in connector type) Sensor purchase and preparation Harness processing by outside order Sensor installation Sensor installation Harness processing Lead time from now on ● Harness processing can be done by outside order at the same time of sensor preparation. No need junction connector. Customer Sensor preparation Sensor installation Harness processor Using cables with connectors Harness processing Lead time further reduced ● Harness processing by outside order is not needed. Lead time and spare part numbers can be reduced. Purchase of sensors and cable with connectors Sensor installation Reduced Customer Sensor preparation Sensor installation Reduced Reduced lead time Digital Fiber Sensor FX-100 SERIES Saving-space with a width of 9 mm 0.354 in Improved stability over both long terms Very slim at only 9 mm 0.354 in. This is much thinner than existing fiber sensors. Even if the difference is small when only using one unit, when using many units this makes a very large difference. Utilizes the standard Panasonic Electric Works SUNX digital fiber sensor element “Four-chemical emitting element” for light emission. The light emission is guaranteed to be stable over long periods of time. [Stable sensing comparison] Light-emitting amount 9 mm 0.354 in FX-100 Three-chemical emitting element 158 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS Long-term stability Simple operation due to clear operation system PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS We are using the operation system of digital pressure sensor DP-100, which has been highly praised since it went on sale. We have separated the settings levels into three levels: RUN mode, SET mode, and PRO mode, making operation simpler and easier. SENSOR OPTIONS Time Functions used during normal operation SIMPLE WIRE-SAVING UNITS • Changing threshold values • Key lock • Quick settings • Code settings WIRE-SAVING SYSTEMS RUN mode Functions used when initializing the sensor and carrying out maintenance Simple setting SET mode • Teaching • L-ON / D-ON setting • Timer setting • Attenuation function • Interference prevention function Equipped with a full complement of digital fiber sensor functions PRO mode • Shift • External input • Reset • GETA • ECO • Display reversing • Surplus value display • Copy • Threshold tracking Special and detailed setting PARTICULAR USE SENSORS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Quick code input function  Simply imputing the default setting “Code (number)” will enable sensor settings. Even if the settings are accidentally changed, imputing the code will restore the default settings. Confirmation can be carried out smoothly via telephone by simply quoting numbers. This can be of great assistance when dealing with foreign country customers. RUN mode MACHINE VISION SYSTEMS UV CURING SYSTEMS Quick setting: Press and simultaneously for 2 sec. Code setting: Press and simultaneously for 4 sec. Selection Guide Fibers Amplifiers Quick setting numbers (summary) No Output operation Timer Light-emitting amount selection Dark-ON None OFF Dark-ON None ON Dark-ON OFF-delay 10 ms OFF Dark-ON OFF-delay 10 ms ON Light-ON ON-delay 40 ms ON Light-ON ON-delay 40 ms OFF Light-ON ON-delay 10 ms ON Light-ON ON-delay 10 ms OFF Refer to “Quick setting function” and “Code setting function” in “PRECAUTIONS FOR PROPER USE” for details. FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 159 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Digital Fiber Sensor FX-100 SERIES Teaching using ON / OFF buttons  SET mode Simply press the ON button when an object is present and OFF when it is not. There is no need to switch settings or make judgments between Light-ON ( ) and Dark-ON ( ). Thru-beam type / Retroreflective type LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Resolves variation in incident light intensity display PRO mode GETA function  Even when performing the same sensing operation, there may be variances in the digital values of the fiber amp. There is no problem with the sensor itself, but the operator may find it troubling. Given value can be corrected with the GETA function, so the apparent variation can be eliminated and the creation of operation manuals can proceed smoothly. Variations in the amount of light received Object present ON Object absent OFF Reflective type Unify at 500 using the GETA function SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Object present ON Object absent OFF STATIC CONTROL DEVICES ENDOSCOPE HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Teaching is possible even without work. Limit teaching function This carries out teaching and sets threshold values only when no object is present (when the incident light amount is stable). This is useful when sensing objects if there are other objects in the background and when sensing minute objects. Teaching can also be carried out using external input. 4,000 [digits] 4,000 [digits] 500 current value 0 Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F * Becomes active when the output operation is set to on, the beams are not received, and when using semi-transparent or mirrored reflective cable. Current value The amount of light received when there is no object If the light receiving level becomes saturated when sensing over short distances or when sensing transparent objects or minute objects, the light emitting amount can be reduced so that stable sensing can be provided without needing to change the response time. On previous models, there was only one light reduction level, but now there are 3 levels plus an automatic mode. As before, even when the fiber and distance settings needed to be altered for proper sensing, this function can allow simple settings alterations. 【Light receiving level saturated】 Threshold value A 4000 Time 0 Stable detection of minute objects or transparent objects SET mode Attenuation function  Actual digit difference: C Upper display limit Light emitting amount changed B Incident light intensity Fibers PRO mode This function seeks changes in the light emitting amount resulting from changes in the environment over long periods (such as dust levels), so that the incident light intensity can be checked at desired intervals and the threshold values can be reset automatically. Reduces the number of man-hours needed for maintenance. Incident light intensity Selection Guide Save maintenance time Threshold tracking function  Because the original value is 500, the displays for the lower limit value will be 500 and the upper limit value will be 4,000. 500 Not displayed MACHINE VISION SYSTEMS UV CURING SYSTEMS ’ to 1,000 Saturated digit difference: D 【Stable sensing】 Incident light intensity PLC / TERMINALS Correcting an incident light intensity display of ‘ display as ‘ ’ Incident light intensity LASER MARKERS , A , B Actual digit difference: C Digital Fiber Sensor Interference prevention function  SET mode FX-101□: Interference prevention for up to 3 units FX-102□: Interference prevention for up to 4 units The emission frequencies can be set separately for each unit in order to avoid interference. The emitted light flashes while setting is in progress, so that you can see at a glance which fiber sensor is currently being set. There is no need to place the amplifiers close together like there was before, and so the amplifiers can be set up apart from each other. * When the emission frequencies are changed, the response times will also change. FX-100 SERIES Setting copy function to reduce man-hours PRO mode and human error  By attaching a fiber sensor to each device that is to be the fiber sensor master, the master sensor settings can be copied along with data transmissions. By synchronizing the settings on all the devices, trouble from setting errors can be prevented, meaning fewer changes to the instruction manuals even when equipment design is changed. Master side Color of lead wire of attached connector cable (Brown) +V (Black) Output + – (White) External input 12 to 24 V DC ±10 % (Blue) 0 V (Black) Output The emitted light and output indicator flash at the same frequency. Multi-function external input  PRO mode Settings such as emission halt, limit / auto teaching, 2-point teaching and ECO settings can be carried out via external input. Also, the threshold value can be memorized. Color of lead wire of attached connector cable (Brown) +V (Blue) 0 V PLC etc, External input lines are equipped as standard Digital display inversion setting  PRO mode PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS (White) External input SIMPLE WIRE-SAVING UNITS (Blue) 0 V Copiable setting Threshold value, output operation setting, timer operation setting, timer period setting, light-emitting amount selection setting (attenuation function), shift setting, ECO setting, digital display inversion setting, and threshold value margin setting (alert function) Flexible mounting without bracket You can choose either DIN rail mounting or mounting with M3 screws through penetrating holes on the side of the amplifier. When mounting directly or installing only one amplifier or installing to a moving part, there is no slippage. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS The viewing orientation of the digital display can be inverted in accordance with the setting direction of the amplifier. Previous products (without inversion function) LASER SENSORS ENDOSCOPE (Black) Output (White) External input FIBER SENSORS PARTICULAR USE SENSORS (Brown) +V Slave side 160 FA COMPONENTS FX-100 SERIES MACHINE VISION SYSTEMS ø3.2 mm 0.126 inφ3.2mm取付穴 mounting holes Turn OFF UV CURING SYSTEMS Can be attached with M3 screws. M3ビスでの取り付けが可能。 Turn ON Alert function  PRO mode When the amount light received approaches the threshold value, the display can be made to blink in order to alert the operator. Incident light intensity The amount of light received ranges from about 900 to 1,100 when the digital indicator flashes. Range of the digital indicator flashing (margin: small) 1,100 approx. 900 approx. The digital indicator flashes. Threshold value of 1,000 Use normal or long distance varieties Response time and sensing range differ with standard or long sensing range types. Select the best type for your needs. Model No. Type Sensing range Selection Guide Fibers Amplifiers FX-500 Response time FX-100 FX-101 Standard type 400 mm 15.748 in Fastest 250 μs FX-300 FX-102 Long sensing range type 1,150 mm 45.276 in Fastest 2.5 ms FX-410 (FT-B8) Electricity consumption saving possibilities ECO After setting, if about 20 seconds go by without any key operations taking place the digital display will turn off and energy consumption is kept under 600 mW. (When illuminated it is under 720 mW) FX-311 FX-301-F7/ FX-301-F 161 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Digital Fiber Sensor FX-100 SERIES ORDER GUIDE Amplifiers Type Appearance LIGHT CURTAINS PRESSURE / FLOW SENSORS Standard type AREA SENSORS Cable set (Note 1) INDUCTIVE PROXIMITY SENSORS M8 plug-in connector type M8 plug-in connector type MICRO PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide M8 plug-in connector type M8 plug-in connector type Cable set (Note 1) MEASUREMENT SENSORS Long sensing range type WIRE-SAVING SYSTEMS NPN open-collector transistor FX-101-Z (Note 3) NPN open-collector transistor FX-101P (Note 2) PNP open-collector transistor FX-101P-Z (Note 3) PNP open-collector transistor FX-101-CC2 NPN open-collector transistor FX-101P-CC2 PNP open-collector collector transistor FX-102 (Note 2) NPN open-collector transistor FX-102-Z (Note 3) NPN open-collector transistor FX-102P (Note 2) PNP open-collector transistor FX-102P-Z (Note 3) PNP open-collector transistor FX-102-CC2 NPN open-collector transistor FX-102P-CC2 PNP open-collector transistor Designation Model No. CN-14A-C1 Connector attached cable Connector attached cable (Flexible type) Description • FC-FX-1 (Protection cover) CN-14A-C3 3 m 9.843 ft CN-14A-C5 5 m 16.404 ft CN-14A-R-C1 1 m 3.281 ft CN-14A-R-C2 2 m 6.562 ft CN-14A-R-C3 3 m 9.843 ft 0.02 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in • CN-24A-C□ ø4 ø0.157 5 m 16.404 ft 2 m 6.562 ft CN-24A-C5 5 m 16.404 ft FX-500 Connector CN-14A Set of 10 housings and 40 contacts FX-100 Amplifier MS-DIN-4 mounting bracket MS-DIN-E Two pcs. per set Copy unit (Note 2) SC-SU1 ø9 ø0.354 M8 connector attached cable CN-24A-C□ Fixing ring CN-24A-C2 End plates M8 connector attached cable CN-14A-C2 (Note 1) 2 m 6.562 ft CN-14A-R-C5 FX-311 * Only include cable set type 31.4 1.236 1 m 3.281 ft M8 connector attached cable FX-301-F7/ FX-301-F • CN-14A-C2 Connector attached cable 2 m 6.562 ft OPTIONS Amplifiers FX-410 Accessory Notes: 1) The connector attached cable CN-14A-C2 is supplied with the amplifier. 2) M  ake sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg. Co., Ltd. (contact: SPHD-001T-P0.5, housing: PAP-04V-S) 3) Make sure to use the optional M8 connector attached cable CN-24A-C□. Fibers FX-300 Output FX-101 (Note 2) Red LED SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Emitting element Model No. For M8 plug-in connector type The connector on one end Cable outer diameter: ø4 mm ø0.157 in Amplifier mounting bracket • MS-DIN-4 Mounting bracket for amplifier When it moves depending on the way it is installed on a DIN rail, these end plates ensure that all amplifiers are mounted together in a secure and fully connected manner. Copy the controller settings to other controllers. Notes: 1) The connector attached cable CN-14A-C2 is supplied with the cable set type FX-10□-CC2. 2) Refer to the copy unit SC-SU1 pages for details. Connector attached cable • CN-14A(-R)-C□ Recommended connector Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Connector • CN-14A Contact Recommended crimping tool Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Housing Digital Fiber Sensor FX-100 SERIES LIST OF FIBERS FIBER SENSORS Thru-beam type (one pair set) LASER SENSORS Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber. Model No. Sensing range (mm in) (Note 1) Standard type FX-101□ Long sensing range type FX-102□ PHOTOELECTRIC SENSORS Type Fiber cable length : Free-cut Dimensions 2 m 6.562 ft P.90 FT-30 135 5.315 400 15.748 Super quality, ø0.5 mm ø0.020 in, Flexible FT-31 130 5.118 340 13.386 M3, Flexible FT-40 320 12.598 870 34.252 Super quality, ø1 mm ø0.039 in, Flexible FT-41 300 11.811 800 31.496 Metal-free P.90 FT-42 300 11.811 800 31.496 M4, Flexible P.90 FT-A8 1,500 59.055 3,500 137.795 (Note 2) 3,500 137.795 (Note 2) 3,500 137.795 (Note 2) 280 11.024 720 28.346 240 9.449 670 26.378 400 15.748 1,150 45.276 FT-A30 FT-AFM2 FT-AFM2E FT-B8 2 m 6.562 ft 2 m 6.562 ft P.90 P.90 P.90 Wide beam 2 m 6.562 ft P.90 P.90 Array P.90 M4 P.90 FT-E12 6 0.236 19 0.748 Ultra-small dia. FT-E13 6 0.236 19 0.748 Ultra-small dia., Flexible FT-E22 15 0.591 60 2.362 Ultra-small dia. FT-E23 22 0.866 80 3.150 Ultra-small dia., Flexible FT-FM2 300 11.811 800 31.496 FT-FM2S 300 11.811 800 31.496 FT-FM2S4 300 11.811 800 31.496 FT-FM10L 9,300 366.142 15,000 590.551 M14, Long sensing range 10 m 32.81 ft P.91 250 9.843 700 27.559 Heat-resistant, 130 °C 266 °F 2 m 6.562 ft P.91 Heat-resistant, Joint 200 °C 392 °F 200 mm 7.874 in (Note 4) P.92 300 mm 11.811 in (Note 4) P.92 500 mm 19.685 in (Note 4) P.92 1 m 3.281 ft P.92 500 mm19.685 in (Note 4) P.92 800 mm 31.496 in (Note 4) P.92 FT-H13-FM2 135 5.315 420 16.535 135 5.315 420 16.535 FT-H20-J50-S (Note 3) 135 5.315 420 16.535 FT-H20-M1 210 8.268 540 21.260 Heat-resistant, 200 °C 392 °F FT-H20-VJ50-S (Note 3) 150 5.906 500 19.685 FT-H20-VJ80-S (Note 3) 150 5.906 500 19.685 Heat-resistant, Joint 200 °C 392 °F Side-view FT-H20W-M1 100 3.937 300 11.811 Heat-resistant, 200 °C 392 °F FT-H30-M1V-S (Note 5) 110 4.331 280 11.024 Vacuum-resistant, Heat-resistant FT-H35-M2 170 6.693 490 19.291 Heat-resistant, 350 °C 662 °F 170 6.693 490 19.291 990 38.976 2,340 92.126 Chemical-resistant, Heat-resistant 1,000 39.370 3,000 118.110 Narrow beam FT-KV1 135 5.315 500 19.685 FT-KV8 1,000 39.370 3,000 118.110 FT-L80Y 1,100 43.307 2,600 102.362 FT-NFM2 130 5.118 280 11.024 FT-NFM2S 130 5.118 280 11.024 FT-NFM2S4 130 5.118 280 11.024 FT-P2 120 4.724 330 12.992 ø1.5 mm ø0.059 in, Flexible M3, Flexible FT-K8 FT-P40 80 3.150 240 9.449 FT-P60 130 5.118 300 11.811 FT-P80 230 9.055 650 25.591 260 10.236 800 31.496 FT-P81X 1 m 3.281 ft 1 m 3.281 ft 1 m 3.281 ft Sleeve 2 m 6.562 ft 1 m 3.281 ft 2 m 6.562 ft 2 m 6.562 ft (Note 6) P.91 P.91 P.91 P.92 P.92 P.92 P.92 2 m 6.562 ft P.93 2 m 6.562 ft (Note 6) P.93 P.93 P.93 2 m 6.562 ft M3, Sleeve P.93 P.93 1 m 3.281 ft P.93 P.93 2 m 6.562 ft M4, Flexible P.93 P.93 1 m 3.281 ft Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long. 3) Heat-resistant joint fibers and ordinary-temperature fibers (FT-FM2) are sold as a set. 4) This is the fiber length (fixed length) for heat-resistant fibers. The ordinary-temperature fibers are free-cut to 2 m 6.562 ft. 5) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). 6) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted. MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS P.92 P.93 M3 M4, Tough flexible P.91 P.91 Side-view Chemical-resistant P.91 P.91 M4, Sleeve FT-H20-J20-S (Note 3) FT-H35-M2S6 500 mm 19.685 in M4 FT-H20-J30-S (Note 3) FT-HL80Y 162 P.94 Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 163 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers Digital Fiber Sensor FX-100 SERIES LIST OF FIBERS Thru-beam type (one pair set) Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber. Model No. Sensing range (mm in) (Note 1) Standard type FX-101□ Long sensing range type FX-102□ Fiber cable length : Free-cut Dimensions ø1 mm ø0.039 in, Flexible 500 mm 19.685 in P.93 FT-PS1 40 1.575 90 3.543 FT-R80 180 7.087 430 16.929 M4, Elbow FT-S20 135 5.315 400 15.748 Super quality, ø0.5 mm ø0.020 in, Flexible FT-S21 130 5.118 340 13.386 ø1.5 mm ø0.059 in, Flexible FT-S30 320 12.598 870 34.252 Super quality, ø1 mm ø0.039 in, Flexible FT-SFM2 300 11.811 800 31.496 ø2.5 mm ø0.098 in FT-SFM2L 760 29.921 2,400 94.488 ø2.5 mm ø0.098 in, Long sensing range 2 m 6.562 ft 2 m 6.562 ft 2 m 6.562 ft 2 m 6.562 ft P.94 P.94 P.94 P.94 P.94 P.94 2 m 6.562 ft FT-SFM2SV2 180 7.087 470 18.504 Side-view FT-SNFM2 130 5.118 280 11.024 ø1.5 mm ø0.059 in P.95 FT-T80 300 11.811 800 31.496 M3 P.95 FT-V10 1,000 39.370 2,350 92.520 FT-V22 140 5.512 380 14.961 FT-V41 FT-V80Y 2 m 6.562 ft Side-view 40 1.575 120 4.724 340 13.386 800 31.496 Chemical-resistant, Side-view 1 m 3.281 ft P.94 P.95 P.95 2 m 6.562 ft P.95 2 m 6.562 ft (Note 3) P.95 FT-W4 80 3.150 220 8.661 M3, Sharp bending P.95 FT-W8 260 10.236 650 25.591 M4, Sharp bending P.95 FT-WA8 1,500 59.055 3,500 137.795 (Note 2) FT-WA30 3,500 137.795 (Note 2) 3,500 137.795 (Note 2) FT-WKV8 700 27.559 2,200 86.614 FT-WR80 215 8.465 570 22.441 430 16.929 1,150 45.276 FT-WR80L FT-WS3 150 5.906 600 23.622 FT-WS4 80 3.150 220 8.661 FT-WS8 260 10.236 650 25.591 FT-WS8L 600 23.622 1,500 59.055 FT-WV42 30 1.181 80 3.150 230 9.055 670 26.378 80 3.150 230 9.055 330 12.992 1,000 39.370 190 7.480 580 22.835 330 12.992 950 37.402 FT-WZ4 FT-WZ4HB FT-WZ7 FT-WZ7HB FX-500 FT-WZ8 FX-100 FT-WZ8E 700 27.559 2,100 82.677 FX-300 FT-WZ8H 1,200 47.244 2,800 110.236 FX-410 FT-Z8 360 14.173 1,000 39.370 FX-311 FT-Z8E 800 31.496 1,850 72.835 FT-Z8H 1,400 55.118 3,100 122.047 FX-301-F7/ FX-301-F Type FT-Z802Y 520 20.472 3,100 122.047 P.95 Wide beam P.95 Narrow beam, Sharp bending P.96 M4, Square head, Sharp bending P.96 ø3 mm ø0.118 in, Sharp bending ø1.5 mm ø0.059 in, Sharp bending ø2.5 mm ø0.098 in, Sharp bending ø3 mm ø0.118 in, Sharp bending 2 m 6.562 ft P.96 P.96 P.96 P.96 P.96 Side-view, Sharp bending P.96 1 m 3.281 ft P.96 P.97 P.97 Rectangular, Compact, Sharp bending P.97 P.97 P.97 2 m 6.562 ft P.97 P.97 Rectangular, Flexible P.97 P.97 Chemical-resistant, Rectangular Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 2) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long. 3) The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted. P.97 Digital Fiber Sensor FX-100 SERIES LIST OF FIBERS FIBER SENSORS Retroreflective type LASER SENSORS Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber. Model No. Sensing range (mm in) (Note 1) (Note 2) Standard type FX-101□ Long sensing range type FX-102□ Type Fiber cable length : Free-cut PHOTOELECTRIC SENSORS Dimensions FR-KV1 15 to 200 0.591 to 7.874 15 to 360 0.591 to 14.173 Wafer mapping P.98 FR-KZ21 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 Narrow beam, Top sensing P.98 FR-KZ21E 20 to 200 0.787 to 7.874 20 to 200 0.787 to 7.874 Narrow beam, Side sensing 100 to 550 3.937 to 21.654 100 to 830 3.937 to 32.677 Sharp bending FR-WKZ11 164 2 m 6.562 in P.98 P.98 Notes: 1) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.  The sensing range of FR-WKZ11 is specified for the RF-13. The sensing range of FR-KZ21, FR-KZ21E is specified for the attached reflector RF-003. The sensing range of FR-KV1 is specified for the attached reflector. Refer to p.166 for sensing range when FR-WKZ11 is used in combination with a reflector (optional). 2) The sensing range of retroreflective type is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs, adjust the threshold value of the amplifier unit before use. MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Reflective type SIMPLE WIRE-SAVING UNITS Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber. WIRE-SAVING SYSTEMS Model No. FD-30 FD-31 FD-40 FD-41 FD-60 FD-61 FD-A15 FD-AFM2 FD-AFM2E FD-B8 FD-E12 FD-E22 FD-EG1 FD-EG2 FD-EG3 FD-EN500S1 FD-ENM1S1 FD-F4 FD-F41 FD-F41Y Sensing range (mm in) (Note 1) (Note 2) Standard type FX-101□ Long sensing range type FX-102□ 45 1.772 155 6.102 35 1.378 140 5.512 45 1.772 155 6.102 35 1.378 140 5.512 140 5.512 420 16.535 120 4.724 410 16.142 125 4.921 250 9.843 105 4.134 285 11.220 85 3.346 245 9.646 170 6.693 440 17.323 3.5 0.138 13 0.512 16 0.630 45 1.772 18 0.709 50 1.969 10 0.394 30 1.181 7 0.276 22 0.866 1 0.039 4 0.157 15 0.591 48 1.890 Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe PFA (fluorine resin) or equivalently transparent pipe, wall thickness 1 mm 0.039 in Applicable pipe diameter: Outer dia. ø6 to ø26 mm ø0.236 to ø1.024 in transparent pipe PVC (vinyl chloride), fluorine resin, polycarbonate, acrylic, glass, wall thickness 1 to 3 mm 0.039 to 0.118 in ø4 mm ø0.157 in Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted FD-F8Y FD-FA90 FD-FM2 Applicable pipe diameter: Outer dia. ø8 mm ø0.315 in or more transparent pipe (When used with the tying bands: ø8 to ø80 mm ø0.315 to ø3.150 in) [PFA (fluorine resin), including translucent] Liquid absent: Beam received, Liquid present: Beam interrupted 100 3.937 410 16.142 Type Super quality, M3, Flexible M3, Flexible Super quality, M4, Flexible M4, Flexible Super quality, M6, Flexible M6, Flexible Wide beam Array, Top sensing Array, Side sensing M6 Ultra-small dia. M3, High precision M3, Sleeve Fiber cable length : Free-cut 2 m 6.562 ft 2 m 6.562 ft 2 m 6.562 ft 2 m 6.562 ft 2 m 6.562 ft 2 m 6.562 ft 1 m 3.281 ft 500 mm 19.685 in 1 m 3.281 ft Dimensions P.99 P.99 P.99 P.99 P.99 P.99 P.99 P.99 P.99 P.99 P.100 P.100 P.100 P.100 P.100 P.100 P.100 P.100 Liquid sensing, Mountable on pipe MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers 2 m 6.562 ft P.100 Amplifiers FX-500 Liquid/Liquid leak sensing P.101 Liquid sensing 2 m 6.562 ft (Note 3) Liquid/Liquid leak sensing 2 m 6.562 ft M6 Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 3) The allowable cutting range is 1,000 mm 39.370 in from the end that the amplifier inserted. P.101 P.101 P.101 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 165 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Digital Fiber Sensor LIST OF FIBERS Reflective type Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber. Model No. FD-FM2S FD-FM2S4 FD-G4 FD-G6 FD-G6X FD-G40 FD-G60 FD-H13-FM2 FD-H18-L31 FD-H20-21 FD-H20-M1 SIMPLE WIRE-SAVING UNITS FD-H25-L43 FD-H25-L45 WIRE-SAVING SYSTEMS FD-H30-KZ1V-S (Note 4) MEASUREMENT SENSORS FD-H30-L32 STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS FX-100 SERIES FD-H30-L32V-S (Note 4) FD-H35-20S FD-H35-M2 FD-H35-M2S6 FD-HF40Y Sensing range (mm in) (Note 1) (Note 2) Standard type FX-101□ Long sensing range type FX-102□ 100 3.937 345 13.583 100 3.937 345 13.583 50 1.969 120 4.724 50 1.969 120 4.724 45 1.772 160 6.299 50 1.969 120 4.724 100 3.937 410 16.142 100 3.937 280 11.024 0 to 10 0.000 to 0.394 90 3.543 120 4.724 0 to 25 0.000 to 0.984 280 11.024 300 11.811 4 to 16 0.157 to 0.630 4 to 23 0.157 to 0.906 7 to 35 0.276 to 1.378 7 to 38 0.276 to1.496 25 to 80 0.984 to 3.150 10 to 220 0.394 to 8.661 2 to 9 0.079 to 0.354 0 to 17 0.000 to 0.669 2.5 to 6.5 0.098 to 0.256 0 to 11 0.000 to 0.433 85 3.346 200 7.874 75 2.953 280 11.024 75 2.953 280 11.024 ø4 mm ø0.157 in Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable) Liquid surface not contacted: Beam received, Liquid surface contacted: Beam interrupted HUMAN MACHINE INTERFACES FD-L4 5 to 8 0.197 to 0.315 (Convergent point 6 0.236) 1 to 17 0.039 to 0.669 (Convergent point 6 0.236) ENERGY CONSUMPTION VISUALIZATION COMPONENTS FD-L41 3 to 14 0.118 to 0.551 (Convergent point 8 0.315) 1.5 to 16 0.059 to 0.630 (Convergent point 8 0.315) 0 to 19 0.000 to 0.748 0 to 25 0.000 to 0.984 0 to 6 0.000 to 0.236 0 to 8 0.000 to 0.315 0 to 4.5 0.000 to 0.177 0 to 5.5 0.000 to 0.217 FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F FD-L43 FD-L44 FD-L44S FD-L45 FD-L45A FD-L46 FD-L47 FD-NFM2 FD-NFM2S FD-NFM2S4 FD-P2 FD-P40 FD-P50 FD-P60 FD-P80 FD-P81X FD-R80 0 to 40 0.000 to 1.575 Fiber cable length : Free-cut Type M6, Sleeve M4, High precision M3, High precision Tough flexible 2 m 6.562 ft 1 m 3.281 ft (Note 3) Metal-free 2 m 6.562 ft Heat-resistant, 130 °C 266 °F Heat-resistant, 180 °C 356 °F Heat-resistant, 200 °C 392 °F M4 M6 Heat-resistant, Convergent reflective Vacuum-resistant, Heat-resistant Heat-resistant, 300 °C 572 °F Vacuum-resistant, Convergent reflective M4, Sleeve Heat-resistant, 350 °C 662 °F M6, Sleeve 1 m 3.281 ft 12 to 50 0.472 to 1.969 30 1.181 35 1.378 100 3.937 35 1.378 100 3.937 35 1.378 100 3.937 25 0.984 65 2.559 8 0.315 30 1.181 45 1.772 150 5.906 45 1.772 150 5.906 90 3.543 200 7.874 70 2.756 220 8.661 70 2.756 180 7.087 FD-S30 45 1.772 155 6.102 FD-S31 35 1.378 140 5.512 P.102 P.102 3 m 9.843 ft 1 m 3.281 ft P.103 2 m 6.562 ft P.103 3 m 9.843 ft P.103 1 m 3.281 ft P.104 P.104 P.104 2 m 6.562 ft Liquid/Liquid leak sensing P.104 2 m 6.562 ft P.104 P.104 1 m 3.281 ft 2 m 6.562 ft P.104 P.104 P.104 P.104 P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.105 P.106 P.106 2 m 6.562 ft P.106 Convergent reflective 0 to 50 0.000 to 1.969 28 1.102 P.101 P.101 P.101 P.102 P.102 P.101 P.102 P.102 P.102 P.103 P.103 3 m 9.843 ft 10 to 33 0.394 to 1.299 (Note 5) 16 to 30 0.630 to 1.181 Dimensions 4 m 13.124 ft 3 m 9.843 ft M4 2 m 6.562 ft M4, Sleeve ø1.5 mm ø0.059 in, Flexible M3, Flexible ø3 mm ø0.118 in, Flexible M4, Flexible M6, Flexible M6, Tough flexible M6, Elbow Super quality, ø3 mm ø0.118 in, Flexible ø3 mm ø0.118 in, Flexible 1 m 3.281 ft 2 m 6.562 ft Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. 3) The allowable cutting range is 700 mm 27.559 in from the end that the amplifier inserted. 4) Sold as a set comprising vacuum type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). 5) The sensing range is changed due to tilt of senseing object. 2 m 6.562 ft P.106 Digital Fiber Sensor FX-100 SERIES LIST OF FIBERS FIBER SENSORS Reflective type LASER SENSORS Fibers are listed in alphabetic order. Refer to p.5~ “Fiber Selection” for details of each fiber. Model No. FD-S80 FD-SFM2SV2 FD-SNFM2 FD-T40 FD-T80 FD-V41 FD-W8 FD-W44 FD-WG4 166 Sensing range (mm in) (Note 1) (Note 2) Standard type FX-101□ Long sensing range type FX-102□ 100 3.937 345 13.583 30 1.181 90 3.543 35 1.378 100 3.937 35 1.378 100 3.937 110 4.331 345 13.583 25 0.984 70 2.756 80 3.150 230 9.055 15 0.591 40 1.575 28 1.102 75 2.953 FD-WKZ1 20 to 180 0.787 to 7.087 20 to 480 0.787 to 18.898 FD-WL41 7 to 12 0.276 to 0.472 (Convergent point 8 0.315) 6 to 13.5 0.236 to 0.531 (Convergent point 8 0.315) FD-WL48 1 to 4.5 0.039 to 0.177 0.5 to 6.5 0.020 to 0.256 FD-WS8 80 3.150 230 9.055 FD-WSG4 28 1.102 75 2.953 FD-WT4 FD-WT8 FD-WV42 FD-WZ4 FD-WZ4HB FD-WZ7 FD-WZ7HB 15 0.591 40 1.575 80 3.150 230 9.055 6 0.236 20 0.787 2 to 20 0.079 to 0.787 1 to 70 0.039 to 2.756 2 to 20 0.079 to 0.787 1 to 70 0.039 to 2.756 1 to 55 0.039 to 2.165 160 6.299 1 to 60 0.039 to 2.362 0.5 to 180 0.020 to 7.087 Type Fiber cable length : Free-cut ø3 mm ø0.118 in Side-view ø2.5 mm ø0.098 in M3 M4 Side-view M6, Sharp bending M4, Sharp bending M4, High precision Long sensing range, Rectangular 2 m 6.562 ft P.106 P.106 P.106 P.106 P.106 P.106 P.107 P.107 P.107 P.107 1 m 3.281ft Rectangular, Compact Sharp bending Dimensions P.107 Convergent reflective ø3 mm ø0.118 in, Sharp bending ø3 mm ø0.118 in, High precision M3, Sharp bending M4, Sharp bending Side-view, Sharp bending PHOTOELECTRIC SENSORS P.107 P.107 2 m 6.562 ft 1 m 3.281ft 2 m 6.562 ft P.107 P.107 P.107 P.108 P.108 P.108 P.108 P.108 MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. 2) Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. HUMAN MACHINE INTERFACES Sensing ranges (mm in) when using in combination with the FR-WKZ11 reflector (optional) ENERGY CONSUMPTION VISUALIZATION COMPONENTS Reflector Amplifier FR-WKZ11 + RF-210 FX-101□ FX-102□ FA COMPONENTS MACHINE VISION SYSTEMS 100 to 700 3.937 to 27.559 100 to 1,100 3.937 to 43.307 FR-WKZ11 + RF-220 100 to 1,300 3.937 to 51.181 100 to 2,600 3.937 to 102.362 FR-WKZ11 + RF-230 100 to 2,000 3.937 to 78.740 100 to 4,000 3.937 to 157.480 UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 167 Digital Fiber Sensor FIBER OPTIONS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS FX-100 SERIES Lens (For thru-beam type fiber) Designation Model No. Description MICRO PHOTOELECTRIC SENSORS Sensing range (mm in) [Lens on both sides] AREA SENSORS Fiber LIGHT CURTAINS PRESSURE / FLOW SENSORS Expansion lens (Note 1) INDUCTIVE PROXIMITY SENSORS FX-LE1 PARTICULAR USE SENSORS 3,000 118.110 3,500 137.795 (Note 2) 1,900 74.803 3,500 137.795 (Note 2) FT-W8 3,000 118.110 3,500 137.795 (Note 2) • Ambient temperature: –60 to +350 °C –76 to +662 °F (Note 4) FT-P80, FT-P60 3,500 137.795 (Note 2) 3,500 137.795 (Note 2) FT-P81X 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) FT-H35-M2 2,000 78.740 3,500 137.795 (Note 2) FT-H20W-M1 1,300 51.181 1,600 62.992 (Note 2) FT-H20-M1 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) FT-H20-J20-S, FT-H20-J30-S, 1,000 39.370 FT-H20-J50-S Fiber For thru-beam type fiber STATIC CONTROL DEVICES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Superexpansion lens (Note 1) Tremendously increases the sensing range with large diameter lenses. FX-LE2 • Ambient temperature: –60 to +350 °C –76 to +662 °F (Note 4) UV CURING SYSTEMS Amplifier FT-P81X 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) FT-H35-M2 3,500 137.795 (Note 2) 3,500 137.795 (Note 2) FT-H20W-M1, FT-H20-M1 1,600 62.992 (Note 2) 1,600 62.992 (Note 2) FT-H13-FM2 3,500 137.795 (Note 2) 3,500 137.795 (Note 2) Sensing range (mm in) [Lens on both sides] Beam axis is bent by 90°. Side-view lens FX-SV1 • Ambient temperature: –60 to +300 °C –76 to +572 °F (Note 4) Amplifier FX-101□ FX-102□ FT-B8 530 20.866 1,450 57.087 FT-FM2, FT-T80 550 21.654 1,700 66.929 FT-W8 450 17.717 1,300 51.181 FT-P80 420 16.535 1,400 55.118 FT-P60 300 11.811 850 33.465 FT-P81X 550 21.654 1,700 66.929 FT-H35-M2 280 11.024 800 31.496 140 5.512 400 15.748 280 11.024 840 33.071 150 5.906 410 16.142 Fiber FT-H20-M1 Selection Guide FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S Fibers FX-500 Expansion lens for vacuumresistant fiber (Note 1) FV-LE1 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F FX-102□ 3,500 137.795 (Note 2) 3,500 137.795 (Note 2) FT-H20W-M1 Amplifiers FX-101□ FT-B8, FT-FM2, FT-R80, FT-W8, FT-P80, FT-P60 FT-H20-J20-S, FT-H20-J30-S, 3,500 137.795 (Note 2) 3,500 137.795 (Note 2) FT-H20-J50-S FA COMPONENTS MACHINE VISION SYSTEMS 3,500 137.795 (Note 2) Sensing range (mm in) [Lens on both sides] MEASUREMENT SENSORS HUMAN MACHINE INTERFACES 3,500 137.795 (Note 2) FT-R80 WIRE-SAVING SYSTEMS PLC / TERMINALS FX-102□ 2,200 86.614 FT-FM2, FT-T80 SIMPLE WIRE-SAVING UNITS LASER MARKERS FX-101□ FT-B8 Increases the sensing range by 5 times or more. SENSOR OPTIONS ENDOSCOPE Amplifier Side-view lens for vacuumresistant fiber FV-SV2 Sensing range increases by 4 times or more. • Ambient temperature: –60 to +350 °C –76 to +662 °F (Note 4) Sensing range (mm in) [Lens on both sides] (Note 3) Beam axis is bent by 90°. Sensing range (mm in) [Lens on both sides] (Note 3) • Ambient temperature: –60 to +300 °C –76 to +572 °F (Note 4) Fiber Fiber Amplifier FT-H30-M1V-S Amplifier FT-H30-M1V-S FX-101□ FX-102□ 450 17.717 1,600 62.992 FX-101□ FX-102□ 450 17.717 1,600 62.992 Notes: 1) Be careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult. Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber), please be sure to use it only after you have adjusted it sufficiently. 2) T  he fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long (FT-H20W-M1, FT-P81X and FT-H20-M1: 1,600 mm 62.992 in). 3) T  he fiber cable length for the FT-H30-M1V-S is 1 m 3.281 ft. The sensing ranges in FX-102□ (long sensing range type) take into account the length of the FT-J8 atmospheric side fiber. 4) For  details on the ambient temperatures for the fibers which being combined, refer to p.76~. Digital Fiber Sensor FX-100 SERIES FIBER OPTIONS FIBER SENSORS LASER SENSORS Lens (For reflective type fiber) Designation Pinpoint spot lens Model No. PHOTOELECTRIC SENSORS Description Pinpoint spot of ø0.5 mm ø0.020 in. Enables detection of minute objects or small marks. • Distance to focal point: 6 ± 1 mm 0.236 ± 0.039 in • Applicable fibers: FD-WG4, FD-G4 • Ambient temperature: –40 to +70 °C –40 to +158 °F (Note 2) FX-MR1 Sensing range for FX-101□ (mm in) (Note 1) The spot diameter is adjustable from ø0.7 to ø2 mm ø0.028 to ø0.079 in according to how much the fiber is screwed in. • Applicable fibers: FD-WG4, FD-G4 • Ambient temperature: –  40 to +70 °C Spot –40 to +158 °F (Note 2) diameter • Accessory: MS-EX-3 (mounting bracket) Screw-in depth Zoom lens FX-MR2 Distance to focal point Screw-in depth Distance to focal point Spot diameter 18.5 0.728 approx. ø0.7 ø0.028 12 mm 0.472 in 27 1.063 approx. ø1.2 ø0.047 14 mm 0.551 in 43 1.693 approx. ø2.0 ø0.079 7 mm 0.276 in For reflective type fiber Sensing range for FX-101□ (mm in) (Note 1) Finest spot lens Extremely fine spot of ø0.3 mm ø0.012 in approx. achieved. • Applicable fibers: FD-WG4, FD-G4, FD-EG1, FD-EG2, FD-EG3, FD-G6X, FD-G6 • Ambient temperature: –  40 to +70 °C –40 to +158 °F (Note 2) FX-MR3 Distance to focal point FX-MR6 Zoom lens Side-view type FX-MR5 Distance to focal point Spot diameter PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS 7.5 ± 0.5 ø0.15 ø0.006 0.295 ± 0.020 approx. WIRE-SAVING SYSTEMS FD-EG2 7.5 ± 0.5 ø0.2 ø0.008 0.295 ± 0.020 approx. FD-EG1 7.5 ± 0.5 ø0.3 ø0.012 0.295 ± 0.020 approx. FD-WG4/G4, FD-G6X/G6 7.5 ± 0.5 ø0.5 ø0.020 0.295 ± 0.020 approx. FD-EG3 7 ± 0.5 ø0.1 ø0.004 0.276 ± 0.020 approx. FD-EG2 7 ± 0.5 ø0.15 ø0.006 0.276 ± 0.020 approx. FD-EG1 7 ± 0.5 ø0.2 ø0.008 0.276 ± 0.020 approx. FD-WG4/G4, FD-G6X/G6 7 ± 0.5 ø0.4 ø0.016 0.276 ± 0.020 approx. Screw-in depth Distance to focal point Spot diameter FX-MR2 is converted into a side-view type and can be mounted in a very small space. • Applicable fibers: FD-WG4, FD-G4 • Ambient temperature: –  40 to +70 °C –40 to +158 °F (Note 2) LIGHT CURTAINS FD-EG3 Sensing range for FX-101□ (mm in) (Note 1) Screw-in depth AREA SENSORS SIMPLE WIRE-SAVING UNITS Fiber model No. Distance to focal point Spot diameter Extremely fine spot of ø0.1 mm ø0.004 in approx. achieved. • Applicable fibers: FD-WG4, FD-G4, FD-EG1, FD-EG2, FD-EG3, FD-G6X, FD-G6 • Ambient temperature: –  20 to +60 °C –4 to +140 °F (Note 2) MICRO PHOTOELECTRIC SENSORS Fiber model No. Distance to focal point Spot diameter Sensing range for FX-101□ (mm in) (Note 1) Spot diameter Finest spot lens 168 8 mm 0.315 in 13 0.512 approx. ø0.5 ø0.020 10 mm 0.394 in 15 0.591 approx. ø0.8 ø0.031 14 mm 0.551 in 30 1.181 approx. ø3.0 ø0.118 Notes: 1) The sensing ranges are the values when used in combination with FX-101□ (standard type). Please contact our office for details on sensing ranges for other types of amplifier. 2) F  or details on the ambient temperatures for the fibers which being combined, refer to p.76~. MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 169 Digital Fiber Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Standard type Type Model No. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS FX-100 SERIES Item Cable set Cable set NPN output FX-101(-Z) (Note 5) FX-101-CC2 FX-102(-Z) (Note 5) FX-102-CC2 PNP output FX-101P(-Z) (Note 5) FX-101P-CC2 FX-102P(-Z) (Note 5) FX-102P-CC2 Supply voltage Power consumption Output PARTICULAR USE SENSORS Long sensing range type 12 to 24 V DC ±10 %   Ripple P-P 10 % or less Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) NPN open-collector transistor PNP open-collector transistor • Maximum sink current: 100 mA • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less (at 100 mA sink current) • Residual voltage: 1.5 V or less (at 100 mA source current) Output operation Selectable either Light-ON or Dark-ON, at SET mode Short-circuit protection SENSOR OPTIONS Incorporated External input NPN non-contact input • Signal condition High: +8 V to +V DC or Open Low: 0 to +2 V DC (Source current 0.5 mA or less) • Input impedance: 10 kΩ approx. STATIC CONTROL DEVICES Response time Emission frequency 0: 250 µs or less (factory default setting) Emission frequency 1: 450 µs or less Emission frequency 2: 500 µs or less Emission frequency 3: 600 µs or less ENDOSCOPE Sensitivity setting SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers Orange LED (lights up when the output is ON) Digital display 4 digits (green) + 4 digits (red) LCD display Fine sensitivity adjustment function Incorporated ON-delay / OFF-delay timer, switchable either effective or ineffective [Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms] Timer function Attenuation function Interference prevention function Ambient temperature 3–level + Auto setting Incorporated Emission frequency selection method (Note 2) (Functions at emission frequency 1, 2 or 3) 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Incandescent light: 3,000 ℓx at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3) Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3) Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each Emitting element (modulated) Red LED (Peak emission wavelength: 632 nm 0.025 mil) Material FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Incorporated Emission frequency selection method (Note 2) (Functions at emission frequency 1, 2, 3 or 4) –10 to +55 °C +14 to +131 °F (If 4 to 7 units are mounted close together: –10 to +50 °C +14 to +122 °F, if 8 to 16 units are mounted close together: –10 to +45 °C +14 to +113 °F) (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F Ambient humidity Voltage withstandability Emission frequency 1: 2.5 ms or less (factory default setting) Emission frequency 2: 2.8 ms or less Emission frequency 3: 3.2 ms or less Emission frequency 4: 5.0 ms or less 2-point teaching / Limit teaching / Full-auto teaching Operation indicator Environmental resistance LASER MARKERS PNP non-contact input • Signal condition High: +4 V to +V DC (Sink current 0.5 to 3 mA) Low: 0 to +0.6 V DC or Open • Input impedance: 10 kΩ approx. Enclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT Connecting method Connector (Note 4) Cable length Weight Accessory Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. Net weight: 15 g approx. Gross weight: 35 g approx. Net weight: 15 g approx. Gross weight: 75 g approx. Net weight: 15 g approx. Gross weight: 35 g approx. Net weight: 15 g approx. Gross weight: 75 g approx. – CN-14A-C2 (Connector attached cable, 2 m 6.562 ft long): 1pc. – CN-14A-C2 (Connector attached cable, 2 m 6.562 ft long): 1pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to different frequency values. However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2. 3) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. 4) Connector attached cable CN-14A-C2 is not attached to the models that have no “-CC2” at the end of the model Nos. Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd. (contact: SPHD-001T-P0.5, housing: PAP-04V-S). 5) Model Nos. having the suffix “-Z” are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C□. Digital Fiber Sensor FX-100 SERIES I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS FX-10□(-Z/-CC2) NPN output type I/O circuit diagram Terminal No. MICRO PHOTOELECTRIC SENSORS Connector type Color code of cable with connector Sensor circuit D +8 V 2 Tr Terminal No. (Brown) +V (Black) Output Load + – 100 mA max. ZD 3 4 (White) External input *1 (Blue) 0 V Internal circuit 12 to 24 V DC ±10 % Function 1 1 +V 2 2 Output 3 External input 4 0V 3 4 Users’ circuit 1 * 1 Terminal No. Function 1 +V 2 Output 3 External input 4 0V 2 Non-voltage contact or NPN open-collector transistor or 3 4 AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS M8 plug-in connector type Symbols … D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : NPN output transistor LASER SENSORS PHOTOELECTRIC SENSORS Terminal arrangement diagram 1 170 High (+8 V to +V DC, or open): Ineffective Low [(0 to +2 V DC (source current 0.5 mA or less)]: Effective SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE FX-10□P(-Z/-CC2) PNP output type I/O circuit diagram Terminal arrangement diagram Terminal No. PLC / TERMINALS Connector type Color code of cable with connector Sensor circuit 1 3 D *1 (White) External input ZD Tr 100 mA max. 2 4 Terminal No. Function 1 1 +V 2 2 Output 3 External input 4 0V (Brown) +V (Black) Output (Blue) 0 V Internal circuit Load + – 12 to 24 V DC ±10 % 3 4 M8 plug-in connector type 1 * 1 Non-voltage contact or PNP open-collector transistor or High [ +4 V to +V DC (sink current 0.5 to 3 mA)]: Effective Low (0 to +0.6 V DC, or open): Ineffective 3 2 4 HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Users’ circuit Symbols … D : Reverse supply polarity protection diode ZD: Surge absorption zener diode Tr : PNP output transistor LASER MARKERS Terminal No. Function 1 +V 2 Output 3 External input 4 0V Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS ENERGY CONSUMPTION VISUALIZATION COMPONENTS L Fiber head 2,000 78.740 300 11.811 FT-P81X ℓ 100 3.937 Fiber head L Fiber head FX-102 FX-101 500 19.685 ℓ 0 400 15.748 100 0 100 200 3.937 3.937 7.874 Left Center Right Operating point ℓ (mm in) Reflective type ℓ Setting distance L (mm in) FX-101 200 7.874 White non-glossy paper ℓ L Fiber head 0 100 3.937 50 0 50 100 1.969 1.969 3.937 Left Center Right Operating point ℓ (mm in) FD-NFM2  FD-NFM2S  FD-NFM2S4 Reflective type FD-SNFM2  FD-T40 Sensing field 0 400 15.748 Reflective type Sensing field Reflective type 0 20 0.787 FX-101 White non-glossy paper ℓ L Fiber head 10 0 10 20 0.394 0.394 0.787 Left Center Right Operating point ℓ (mm in) Setting distance L (mm in) 50 1.969 200 7.874 100 3.937 0 40 1.575 FX-101 FX-101 White non-glossy paper ℓ L Fiber head White non-glossy paper ℓ L Fiber head 20 0 20 40 0.787 0.787 1.575 Left Center Right Operating point ℓ (mm in) 0 40 1.575 Fiber head L Fiber head 100 0 100 200 3.937 3.937 7.874 Left Center Right Operating point ℓ (mm in) FD-G6X Reflective type 150 5.906 FX-102 100 3.937 FX-101 White non-glossy paper ℓ L Fiber head 50 1.969 0 40 1.575 20 0 20 40 0.787 0.787 1.575 Left Center Right Operating point ℓ (mm in) 20 0 20 40 0.787 0.787 1.575 Left Center Right Operating point ℓ (mm in) FD-WG4  FD-WSG4 Reflective type Sensing field 80 3.150 FX-102 FX-101 100 3.937 ℓ 200 7.874 Sensing field FX-102 FX-101 Sensing field FD-W8  FD-WS8  FD-WT8 Reflective type 200 7.874 FX-102 200 7.874 0 200 7.874 FX-102 100 3.937 200 0 200 400 7.874 7.874 15.748 Left Center Right Operating point ℓ (mm in) 400 15.748 50 0 50 100 1.969 1.969 3.937 Left Center Right Operating point ℓ (mm in) 50 1.969 0 40 1.575 50 0 50 100 1.969 1.969 3.937 Left Center Right Operating point ℓ (mm in) L FT-W8  FT-WS8 Thru-beam type FX-102 White non-glossy paper ℓ L Fiber head FD-P81X L Sensing field FX-101 200 7.874 Fiber head Fiber head 100 3.937 Fiber head Fiber head 600 23.622 100 3.937 FD-G4 ℓ 800 31.496 FX-101 0 100 3.937 FX-101 Parallel deviation FX-102 200 7.874 FX-102 500 19.685 500 0 500 1,000 19.685 19.685 39.370 Left Center Right Operating point ℓ (mm in) FT-W4  FT-WS4 Thru-beam type 200 0 200 400 7.874 7.874 15.748 Left Center Right Operating point ℓ (mm in) 400 15.748 FX-102 0 100 3.937 Setting distance L (mm in) FX-311 L Sensing field 400 15.748 L Fiber head FX-102 FX-300 FX-301-F7/ FX-301-F Fiber head Fiber head FD-FM2 Reflective type Sensing field Amplifiers FX-410 0 1,000 39.370 ℓ Fiber head Parallel deviation 1,000 39.370 FX-101 FD-B8 Fibers FX-100 Thru-beam type Parallel deviation FX-102 200 7.874 0 200 7.874 Selection Guide FX-500 500 19.685 400 15.748 Setting distance L (mm in) UV CURING SYSTEMS ℓ 8 mm 0.315 in approx. L FA COMPONENTS MACHINE VISION SYSTEMS Fiber head 1,000 39.370 FX-102 FX-101 Fiber head 0 200 100 0 100 200 7.874 7.874 3.937 3.937 Down Center Up Operating point ℓ (mm in) 100 0 100 200 3.937 3.937 7.874 Left Center Right Operating point ℓ (mm in) Parallel deviation FX-101 1,000 39.370 FT-NFM2  FT-NFM2S Thru-beam FT-NFM2S4  FT-SNFM2 type PLC / TERMINALS HUMAN MACHINE INTERFACES ℓ Fiber head Parallel deviation White non-glossy paper ℓ L Fiber head 20 0 20 40 0.787 0.787 1.575 Left Center Right Operating point ℓ (mm in) Setting distance L (mm in) SIMPLE WIRE-SAVING UNITS Setting distance L (mm in) SENSOR OPTIONS FX-101 1,000 39.370 PARTICULAR USE SENSORS 1,000 39.370 FT-FM2  FT-FM2S  FT-FM2S4 Thru-beam type FT-SFM2  FT-T80 Setting distance L (mm in) 2,000 78.740 0 200 7.874 FX-102 3,000 118.110 Setting distance L (mm in) INDUCTIVE PROXIMITY SENSORS FX-102 3,000 118.110 Thru-beam type Parallel deviation 4,000 157.480 Setting distance L (mm in) PRESSURE / FLOW SENSORS • Vertical direction 4,000 157.480 FT-B8 Setting distance L (mm in) LIGHT CURTAINS Parallel deviation • Horizontal direction Setting distance L (mm in) AREA SENSORS Thru-beam type Setting distance L (mm in) MICRO PHOTOELECTRIC SENSORS FT-A8 Setting distance L (mm in) PHOTOELECTRIC SENSORS Contact our office for sensing characteristics that are not contained here. Setting distance L (mm in) SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS LASER SENSORS FX-100 SERIES Setting distance L (mm in) Digital Fiber Sensor Setting distance L (mm in) 171 FX-102 60 2.362 40 1.575 20 0.787 0 20 0.787 FX-101 White non-glossy paper ℓ L Fiber head 10 0 10 20 0.394 0.394 0.787 Left Center Right Operating point ℓ (mm in) Digital Fiber Sensor • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Using in combination with the FX-300 / FX-410 series • The FX-100 series does not use the horizontal connectors that are used with the FX-300 / FX-410 series. Please note that horizontal connection cannot be performed using a connector attached cable. In addition, the optical communication function is not equipped on the FX-100 series, so it is unable to perform interference prevention for use with the FX-300 / FX-410 series. If using the FX-100 series together with the FX-300 / FX-410 series side-by-side, please set the same models together in groups. Mounting How to mount the amplifier 2  it the rear part of the mounting F section of the amplifier on a 35 mm 1.378 in width DIN rail. Press down the rear part of the mounting section of the unit on the 35 mm 1.378 in width DIN rail and fit the front part of the mounting section to the DIN rail. 2 1 2 Push the amplifier forward. Lift up the front part of the amplifier to remove it. LASER SENSORS • Make sure that the power supply is OFF while adding or removing the amplifiers. • Note that if a voltage exceeding the reted range is applied, or if an AC power supply is directly connected, the product may get burnt or damaged. • Note that short-circuit of the load or wrong wiring may burn or damage the product. • Do not run the wires together with high-voltage lines or power lines, or put them in the same raceway. This can cause malfunction due to induction. • Verify that the supply voltage variation is within the rating. • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. • Make sure to use the quick-connection cable (optional) for the connection of the controller.  Extension up to total 100 m 328.084 ft is possible with 0.3 mm2 or more, cable. However, in order to reduce noise, make the wiring as short as possible. PHOTOELECTRIC SENSORS Operation indicator (Orange) MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS ON key / Setting value UP key OFF key / Setting value DOWN key MODE key PLC / TERMINALS HUMAN MACHINE INTERFACES 35 mm 1.378 in width DIN rail Digital display (Green) (Threshold value) 2 FIBER SENSORS Wiring Part description How to remove the amplifier 1 172 Refer to General precautions, and to the “Operation Guide” on our website for details pertaining to operating instructions for the amplifier. PRECAUTIONS FOR PROPER USE 1 FX-100 SERIES Digital display (Red) (Incident light intensity) ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS 1 Setting mode • Setting mode appears after the MODE key is pressed for 2 sec. in RUN mode. Note: Take care that if the front part is lifted without pushing the amplifier forward, the hook on the rear portion of the mounting section is likely to break. • Use M3 screws with washers for mounting. The tightening torque should be 0.5 N·m or less. Setting item Factory setting Teaching mode Output operation setting Timer operation setting M3 screw with washer Timer setting Emission amount setting Description Threshold value can be set in 2-point teaching, limit teaching, or full-auto teaching. [Dark-ON] [Without timer] Light-ON or Dark-ON can be set. 1 (Response time: 2.5 ms or less) Fibers Amplifiers In case of setting ON-delay timer or OFF-delay FX-300 can be set. When timer is not set, this mode is [OFF-delay timer: 10 ms] not displayed. 0 (Response time: 250 µs or less) FX-102□ Selection Guide FX-500 Setting for reduced intensity of emission amount is possible when the incident light intensity is saturated. FX-101□ Emission frequency setting UV CURING SYSTEMS Without timer, ON delay timer, or OFF delay timer can be set. [ON-delay timer: 10 ms] timer in the timer operation setting mode, timer Level 3 MACHINE VISION SYSTEMS In case of using the fiber heads in parallel, interference can be prevented by setting different emission frequency. However, when emission frequency 0 is set, interference cannot be prevented. Response time corresponds to emission frequency. FX-100 FX-410 FX-311 FX-301-F7/ FX-301-F 173 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Digital Fiber Sensor INDUCTIVE PROXIMITY SENSORS PRO mode • PRO mode appears after the MODE key is pressed for 4 sec. in RUN mode. Setting item Factory setting Shift setting External input setting PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES Threshold value-storing setting mode (Note 2) Threshold value follow-up cycle setting (Note 3) PLC / TERMINALS HUMAN MACHINE INTERFACES GETA function setting (Note 4, 5) ENERGY CONSUMPTION VISUALIZATION COMPONENTS ECO setting FA COMPONENTS Digital display inversion setting MACHINE VISION SYSTEMS [OFF] [OFF] [OFF] [OFF] Selection Guide [OFF] Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F Setting copy Reset • Be sure to use the setting copy function between the identical models (Between FX-101□ models or FX-102□ models). This function cannot be used between different models. • Only one sensor can be connected on slave side with a master side sensor for the setting copy function. • Threshold value, output operation setting, timer operation setting, timer setting, light-emitting amount setting, shift setting, external input setting, threshold value margin setting, ECO setting, digital display inversion setting, and threshold value margin setting can be copied. Threshold value set at the limit teaching, full-auto teaching or 2-point teaching by external input is stored. When selecting Auto in the emission amount setting mode, the set emission amount level is also stored. When incident light intensity exceeds threshold value, this mode can change the threshold value with each set cycle depending on variations of the incident light intensity. The follow-up shift amount is same as the one set in the shift setting mode. However, the threshold value is not stored. Variations can be reduced by correcting the present incident light intensity in each amplifier to a target value. Target value to offset incident light intensity can be selected from 0 to 2,000 by 100 unit each. For example, if the target value is set to 2,000 when the incident light intensity is 1,500, the incident light intensity becomes 2,000. It is possible to light up / turn off the digital display. When ECO setting mode is ON, the display turns off in 20 sec. approx. in RUN mode. To light up the display again, press any key for 2 sec. or more. 1 Set the setting copy mode of the master side amplifier to “Copy sending ON”, and press the MODE key so that “ ” is shown on the digital display and the sensor is in copy ready state. For the setting method, refer to “Operation guide”. 2 Turn off the master side amplifier. 3 Connect the master side amplifier with the slave side amplifier as shown below. Color code of cable with connector Master side amplifier (Brown) +V (Black) Input (White) External input + – 12 to 24V DC ±10 % (Blue) 0 V Slave side amplifier (Brown) +V (Black) Input (White) External input (Blue) 0 V [OFF] UV CURING SYSTEMS Threshold value margin setting Description Setting copy function • This can copy the settings of the master side amplifier to the slave side amplifier. Refer to the copy unit SC-SU1 for details. Shift amount can be selected from 0 to 80 % in the limit teaching. Select 0 % when it is desired [Shift amount 15 %] to set the present incident light intensity as a threshold value. External input can be selected from emission halt, limit teaching [+], limit teaching [-], full-auto teaching, ECO (Note 1), 2-point teaching or emission amount test. When setting the incident ”, output turns ON / light intensity test “ OFF every 100ms when the rate of incident [Emission halt] light intensity and threshold value is less than half of the set shift amount (for example, when the rate of incident light intensity and threshold value is within ±10 % for 20 % of shift amount) at external input. ENDOSCOPE LASER MARKERS Refer to General precautions, and to the “Operation Guide” on our website for details pertaining to operating instructions for the amplifier. PRECAUTIONS FOR PROPER USE LIGHT CURTAINS PRESSURE / FLOW SENSORS FX-100 SERIES [NO] [NO] Digital display can be inverted.  urn on the master side amplifier and the slave side T amplifier at the same time. (Note) 5 “ ” is shown on the green digital display of the master side amplifier and 4-digit code is shown on the red digital display of it, then the copying starts. During copy communication, “ ” is shown on the green digital display of the slave side amplifier, and the ongoing copy communication indicator (“ ”→“ ”→“ ”→ ”→“ ”→“ ”→“ ”→“ ”) is displayed on “ the red digital display. 6 When the copying is completed, “ ” is shown on the green digital display of the slave side amplifier, while the 4-digit code (the same code as the master side amplifier) is shown on the red digital display of it. 7 Turn off the power of the master side amplifier and the slave side amplifier and disconnect the wire. 4 Margin for threshold value to the present incident light intensity can be checked. When there is no margin, it is possible to make the digital display blink. : Set to “OFF”: does not function. : Green blinks. : Red blinks. : Red and green blink. : When conducting limit teaching or 2-point teaching by external input, in case the rate of reference incident light intensity and threshold value after teaching is 200% or more, or in case it is less than half of the shift amount, output turns ON / OFF every 100 ms. (Note 6) The settings of the master side amplifier can be copied to the slave side amplifier. For details, refer to “Setting copy function”. Returns to default settings (factory settings.) Notes: 1) When ECO is selected at the external input setting mode, key operation on the main body is invalid during external input. 2) This mode is not indicated unless any of “ ”, “ ”, ” or “ ” is set at the external input setting mode. “ 3) If the incident light intensity becomes “300” or less, the follow-up operation stops. In that condition, threshold value [digital display (green)] blinks. This function can be used when thru-beam type or retroreflective type fiber is applied to this product. If reflective type fiber is applied, the function cannot be used depending on use conditions. 4) If MODE key is pressed in RUN mode when GETA function is used, the incident light intensity before setting GETA function is displayed on the red digital display for 2 sec. approx. 5) When GETA function is used in saturation of incident light intensity (4,000 or more,) “ ” is indicated on the red digital display. Correction value is up to 4,000. 6) This mode does not operate unless any of “ ”, “ ” or ” is set at the external input setting mode. “ * If copying the settings to another amplifier repeatedly, follow the steps 3 to 7 . Note: Take care that if the power is not turned on at the same time, the setting contents may not be copied. 1 2 W  hile the slave side amplifier is disconnected, turn on the power of the master side amplifier. Press the MODE key for 2 sec. approx. Digital Fiber Sensor Refer to General precautions, and to the “Operation Guide” on our website for details pertaining to operating instructions for the amplifier. PRECAUTIONS FOR PROPER USE Others Code setting function • The code setting function makes it possible to set the output operation, timer operation, amount of light emitted, frequency of light emitted, ECO setting, external input, and amount of shift by selecting a code of one’s choice. • While in the RUN Mode, pressing and holding both the ON key ( ) and OFF key ( ) simultaneously for 4 seconds will switch to the code setting function. 1st digit Output Timer operation (Note 1) Timer 2nd digit D-ON 3rd digit Emission frequency Shift (Note 1) 5% non 0 1 Emission halt ond 10 ms 1 2 Limit teaching [+] 2 3 ond 40 ms OFF Limit teaching [-] non Level 3 (OFF) D-ON non Level 2 (ON) D-ON ofd 10 ms Level 3 (OFF) D-ON ofd 10 ms Level 2 (ON) D-ON ofd 40 ms Level 3 (OFF) D-ON ofd 40 ms Level 2 (ON) D-ON ond 10 ms Level 3 (OFF) D-ON ond 10 ms Level 2 (ON) D-ON ond 40 ms Level 3 (OFF) D-ON ond 40 ms Level 2 (ON) L-ON ond 40 ms Level 2 (ON) L-ON ond 40 ms Level 3 (OFF) L-ON ond 10 ms Level 2 (ON) L-ON ond 10 ms Level 3 (OFF) L-ON ofd 40 ms Level 2 (ON) L-ON ofd 40 ms Level 3 (OFF) L-ON ofd 10 ms Level 2 (ON) L-ON ofd 10 ms Level 3 (OFF) L-ON non Level 2 (ON) L-ON non Level 3 (OFF) PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS 15 % 4 ofd 40 ms 0 1 ECO 1 2 Emission halt 30 % ond 10 ms 2 3 Limit teaching [+] 35 % ond 40 ms 3 4 Limit teaching [-] 40 % ofd 10 ms ofd 40 ms ON 0 1 Full-auto teaching 1 2 ECO 2 3 2-point teaching 20 % 25 % 45 % 50 % Level 1 OFF 3 4 Incident light intensity test 0 1 2-point teaching ON 1 2 Incident light intensity test Auto 2 3 3 4 PARTICULAR USE SENSORS SENSOR OPTIONS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE 3 Level 2 (ON) L-ON 10 % ofd 10 ms non INDUCTIVE PROXIMITY SENSORS SIMPLE WIRE-SAVING UNITS Full-auto teaching Emission amount setting D-ON 4th digit Emission External ECO amount input setting FX-101□ FX-102□ Level 3 (OFF) Output operation LASER SENSORS PRESSURE / FLOW SENSORS Quick setting function • The quick setting function makes it possible to set the content of the SET Mode (output operation, timer operation, amount of light emitted, and frequency of light emitted) simply by selecting a setting number. • While in the RUN Mode, pressing and holding both the ON key ( ) and OFF key ( ) simultaneously for 2 seconds will switch to the quick setting function. FIBER SENSORS LIGHT CURTAINS Code • Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. • Take care that the product is not directly exposed to fluorescent lamp from a rapid-starter lamp, a high frequency lighting device or sunlight etc., as it may affect the sensing performance. • This product is suitable for indoor use only. • Avoid dust, dirt, and steam. • Take care that the product does not come in contact with oil, grease, organic solvents, such as thinner, etc., strong acid or alkaline. • This product cannot be used in an environment containing inflammable or explosive gases. • Never disassemble or modify this product. • EEPROM is adopted to this product. It is not possible to conduct teaching 100 thousand times or more, because of the EEPROM’s lifetime. No. 174 FX-100 SERIES Notes: 1) When the present setting is out of the code setting range, “ ” is shown. When “ ” is selected, the set content of the digit is not changed. 2) The factory setting is “ ”. LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Fibers Amplifiers FX-500 FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 175 FIBER SENSORS LASER SENSORS Digital Fiber Sensor DIMENSIONS (Unit: mm in) MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS The CAD data in the dimensions can be downloaded from our website. FX-101□   FX-102□ PHOTOELECTRIC SENSORS AREA SENSORS FX-100 SERIES 0.8 0.031 Amplifier 48 1.890 30 1.181 20 13.2 0.787 0.520 6 0.236 FX-101(P)-Z  FX-102(P)-Z Amplifier 10.85 6 0.236 2.7 0.106 0.7 0.028 0.8 0.031 OFF key / Setting value DOWN key ON key / Setting value UP key MODE key 4.1 Operation indicator (Orange) 0.161 Digital display (Green, Red) 6 0.236 6 0.236 0.427 48 1.890 30 1.181 20 13.2 0.787 0.520 2.7 0.106 0.7 0.028 OFF key / Setting value DOWN key ON key / Setting value UP key MODE key 4.1 Operation indicator (Orange) 0.161 Digital display (Green, Red) PRESSURE / FLOW SENSORS 0.75 0.030 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS 66.2 2.606 9 0.354 7 0.276 4 0.157 10 3 0.118 0.394 WIRE-SAVING SYSTEMS 6.5 0.256 MEASUREMENT SENSORS 14.5 0.571 STATIC CONTROL DEVICES 7 0.276 4 0.157 10 3.2 2 0.126 3 0.118 ø3.2 ø0.126 6.5 0.256 0.079 1 0.039 0.8 0.031 0.394 8.1 0.319 ø3.2 ø0.126 50 1.969 35 1.378 65.5 2.579 6 0.236 1.1 0.043 2 0.079 10 30 0.394 1.181 0.8 0.031 66.2 2.606 9 0.354 2 0.079 6 0.236 1.1 0.043 SIMPLE WIRE-SAVING UNITS 0.75 0.030 14.5 0.571 50 1.969 35 1.378 65.5 2.579 Suitable for 35 mm 1.378 in width DIN rail ø6.5 ø0.256 10 30 0.3941.181 3.2 8.1 0.126 0.319 2 0.079 Suitable for 35 mm 1.378 in width DIN rail ENDOSCOPE LASER MARKERS PLC / TERMINALS MS-DIN-4 Amplifier mounting bracket (Optional) ø7.2 mm ø0.283 in spot facing, 4 0.157 deep HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS 9.25 0.364 ø6.2 mm ø0.244 in spot facing, 3 0.118 deep 4 0.157 UV CURING SYSTEMS 5 0.197 Material: PBT Fibers FX-100 FX-300 FX-410 FX-311 FX-301-F7/ FX-301-F 2.75 0.108 3 0.118 15 0.591 1 0.039 15 0.591 (0.3158 ) ( 35 1.378 ) End plate (Optional) 7.2 mm 0.283 in spot facing, 4 0.157 deep M3 (Iength 18 mm 0.709 in) pan head screws 60 2.362 3 0.118 6.2 mm 0.244 in spot facing, 3 0.118 deep 9 0.354 3.2 0.126 ø3.2 ø0.126 1.6 0.063 1 0.039 24.5 0.965 35 1.378 M3 square nut 5.6 0.220 24.7 0.972 32 1.260 4 0.157 Suitable for 35 mm 1.378 in width DIN rail Material: Polycarbonate CN-14A-C□   CN-14A-R-C□ Amplifiers FX-500 3.2 0.126 11.5 0.453 MACHINE VISION SYSTEMS Selection Guide ø3.2 ø0.126 MS-DIN-E Connector attached cable (Optional) L ( ) 50 1.969 ø3.7 ø0.146 cable CN-14A-C2 is attached FX-101(P)-CC2 / FX-102(P)-CC2 • Length L (0.3158 ) Model No. CN-14A(-R)-C1 CN-14A(-R)-C2 CN-14A(-R)-C3 CN-14A(-R)-C5 Length L 1,000 39.370 2,000 78.740 3,000 118.110 5,000 196.850 176 MEMO
FX-101 价格&库存

很抱歉,暂时无法提供与“FX-101”相匹配的价格&库存,您可以联系我们找货

免费人工找货
FX-101
  •  国内价格 香港价格
  • 1+1113.290151+134.28920
  • 3+1040.500983+125.50910
  • 10+967.8054910+116.74030

库存:3