183
FIBER
SENSORS
Slim Body Analog Fiber Sensor
FX-11A
Related Information
■ General terms and conditions............. P.1
■ Glossary of terms.......................... P.983~
■ Sensor selection guide .......P.11~ / P.61~
■ General precautions...................... P.986~
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
SUNX website
http://www.sunx.com
STATIC CONTROL
DEVICES
LASER
MARKERS
Selection
Guide
Fibers
FT / FD / FR
Fiber Sensor
Amplifiers
Amplifi
ers
Interference
prevention
Analog output type for diverse applications
Analog voltage output
Slim size
It incorporates an analog voltage output of 1 to 5 V.
Being only 10 mm 0.394 in
thick, it can be mounted in a
narrow space.
Various uses
In combination with various types of fibers and the ultracompact digital panel controller, CA2 series, FX-11A
can be used for various applications, such as, height
evaluation, level detection by differential sensing, etc.
Only
10 mm 0.394 in
thick
10 mm
0.394 in
FX-100
FX-300
Saturation indicator
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
CA2 series (Refer to p.793~.)
Digital panel controller
Interference prevention function
Two sets of fibers can be mounted close together or face
to face.
The saturation indicator lights up when the output
reaches 5 V. Hence, the sensitivity can be easily
adjusted even without using a tester.
Moreover, an incident beam indicator which brightens
up in proportion to the amount of incident beam (output
voltage) is also incorporated.
Incident beam indicator (Red)
Saturation indicator (Green)
Slim Body Analog Fiber Sensor
ORDER GUIDE
SPECIFICATIONS
P.184~
P.187
I/O CIRCUIT DIAGRAMS SENSING CHARACTERISTICS PRECAUTIONS FOR PROPER USE
P.188
P.188~
FX-11A
DIMENSIONS
P.190
184
P.190
APPLICATIONS
FIBER
SENSORS
Detecting level difference
Ascertaining the number of translucent films
Measuring inner diameter of rings
When differential sensing is used, no
sensitivity readjustment is required even if
the reflectivity of the objects changes.
The number of overlapping translucent
films can be ascertained.
Rings can be sorted according to their
inner diameter.
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
ORDER GUIDE
PARTICULAR
USE
SENSORS
Accessory
Amplifier
Appearance
Model No.
FX-11A
Supply voltage
Analog output
12 to 24 V DC ± 10 %
Analog voltage
• Output voltage: 1 to 5 V
• MS-DIN-2
(Amplifier mounting bracket)
Shape of fiber head
(mm in)
Long sensing
range
Lens mountable
STATIC
CONTROL
DEVICES
LASER
MARKERS
Sensing range (Note 1,2)
160 mm
6.299 in
125 mm
4.921 in
M4
With lens
ø2.5 ø0.098
Lens mountable
Features
Fiber cable length
:
free cut
• Twice the sensing range for the
same diameter
2 m 6.562 ft
• Long sensing range with small
fiber heads of ø2.5 mm ø0.098 in
2 m 6.562 ft
M4
85 mm
3.346 in
M4
ø1.48
ø0.058
• Free-cut type
With sleeve 90 mm 3.543 in
2 m 6.562 ft
Standard
85 mm
3.346 in
• Miniature head but having the same
sensing range as the standard type fiber
2 m 6.562 ft
Thru-beam
M3
ø0.88
ø0.035
• Suitable for detection in a
congested equipment
• Free-cut type
23 mm
0.906 in
2 m 6.562 ft
Long sensing
Wide beam Small diameter Standard range
Array
Sharp bend
M4
M3
ø1.5 ø0.059
Sensing width
11 mm 0.433 in
8 mm
0.315 in
FT-W4
• The wide beam detects an object at
any place within the range.
2 m 6.562 ft
• The wide beam detects an object at
any place within the range.
2 m 6.562 ft
15
0.591
Side sensing
15
0.591
FT-WS8
FT-WS4
100 mm
3.937 in
W4.2 × H31 × D13.5
W0.165 × H1.220 × D0.531
FT-W8
2 m 6.562 ft
65 mm
2.559 in
FX-100
FX-300
FX-410
FT-NFM2S4
FT-WS8L
• The fiber can be bent sharply, like
an electric wire, to avoid space
wastage in installation because of
its small allowable bending radius of
R1 mm R0.039 in or more.
35 mm
1.378 in
FT / FD / FR
Fiber
Fiber Sensor
Sensor
Amplifi
ers
Amplifiers
FX-311
With sleeve 40 mm 1.575 in
100 mm
3.937 in
Fibers
FX-11A
FT-SNFM2
ø3 ø0.118
Selection
Guide
FT-NFM2S
With sleeve 90 mm 3.543 in
ø1.5 ø0.059
ø2.5 ø0.098
FT-T80
FT-NFM2
With sleeve
Special use
FT-FM2S4
FT-SFM2
M3
Top sensing
FT-SFM2L
With sleeve 40 mm 1.575 in
M3
Lens mountable
FT-B8
FT-FM2S
ø2.5 ø0.098
With lens
Model No.
FT-FM2
With sleeve
Lens mountable
WIRESAVING
SYSTEMS
MEASUREMENT
SENSORS
Fibers [Thru-beam type (one pair set)]
Type
SENSOR
OPTIONS
FT-A8
FT-AFM2
FT-AFM2E
Notes: 1) The sensing range is defined as the range until the saturation indicator lights up.
2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
FX-301-F
Other
Products
185
Slim Body Analog Fiber Sensor
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
Fibers [Reflective type]
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Shape of fiber head
(mm in)
Long sensing
range
Type
AREA
SENSORS
31 mm
1.220 in
M6
Standard
SENSOR
OPTIONS
M3
Small diameter
ø3 ø0.118
WIRESAVING
SYSTEMS
Reflective
ø1.48
ø0.058
Standard
High precision
Sharp bend
M6
Other
Products
FD-T80
• Miniature head but having the same
sensing range as the standard type
fiber
7 mm
0.276 in
22 mm
0.866 in
FD-T40
2 m 6.562 ft
FD-S80
• Suitable for detection in a congested
equipment
• Free-cut type
7 mm
0.276 in
2 m 6.562 ft
FD-NFM2S
With sleeve 90 mm 3.543 in
FD-NFM2S4
With sleeve 40 mm 1.575 in
FD-SNFM2
8 mm
0.315 in
FD-W8
M4
ø3 ø0.118
• The fiber can be bent sharply, like
an electric wire, to avoid space
wastage in installation because
of its small allowable bending
radius of R1 mm R0.039 in or more
(FD-WG4, FD-WSG4: R2 mm
R0.079 in or more).
8 mm
0.315 in
Coaxial M4
Lens mountable
Coaxial ø3 ø0.118
3 mm
0.118 in
FD-WT8
2 m 6.562 ft
FD-WS8
FD-WG4
FD-WSG4
Top sensing
20 0.787
Side sensing
20
High precision
Special use
Array
FD-AFM2
FT / FD / FR
FX-301-F
FD-FM2S
With sleeve 90 mm 3.543 in
FD-FM2S4
With sleeve 40 mm 1.575 in
ø2.5 ø0.098
Fibers
FX-11A
2 m 6.562 ft
FD-NFM2
With sleeve
M4
Selection
Guide
FX-311
• Free-cut type
M4
MEASUREMENT
SENSORS
FX-410
FD-B8
22 mm
0.866 in
M4
PARTICULAR
USE
SENSORS
FX-300
Model No.
2 m 6.562 ft
ø2.5
ø0.098
INDUCTIVE
PROXIMITY
SENSORS
FX-100
Fiber cable length
:
free cut
FD-FM2
M6
Fiber Sensor
Sensor
Fiber
Amplifiers
Amplifiers
Features
• Long sensing range
22 mm
0.866 in
With sleeve
PRESSURE
SENSORS
LASER
MARKERS
Sensing range (Note 1,2)
Coaxial M6
SAFETY
COMPONENTS
STATIC
CONTROL
DEVICES
FX-11A
13 mm
0.512 in
• Its wide beam meets various needs.
2 m 6.562 ft
FD-AFM2E
0.787
Coaxial M4
Lens mountable
Coaxial • Small head
M3
Lens mountable
10 mm
0.394 in
• Precise position sensing with
coaxial fiber
• Combination with the FX-MR3 lens
gives an extremely small spot
diameter of ø0.3 mm ø0.012 in approx.
3 mm
0.118 in
2 m 6.562 ft
500 mm
19.685 in
Notes: 1) The sensing range is defined as the range until the saturation indicator lights up.
Further, for the reflective type fibers, it is specified for white non-glossy paper
[50 × 50 mm 1.969 × 1.969 in (FD-B8: 100 × 100 mm 3.937 × 3.937 in)] as the object.
2) Please take care that the sensing range of free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
Accessories
• FX-CT2 (Fiber cutter)
• FX-AT10 (ø1 mm ø0.039 in fiber attachment)
• FX-AT13 (ø1.3 mm ø0.051 in fiber attachment)
• FX-CT2
• FX-AT10
• FX-AT13
FD-G4
FD-EG1
Slim Body Analog Fiber Sensor
FX-11A
186
OPTIONS
For reflective type fiber
For thru-beam type fiber
Designation
FIBER
SENSORS
Model No.
Description
FX-LE1
Increases the sensing range by 6 times or more.
• Sensing range (Lens on both sides) (Note 1):
900 mm 35.433 in (FT-B8), 750 mm 29.528 in (FT-FM2,
FT-T80), 350 mm 13.780 in (FT-W8)
FX-LE2
Tremendously increases the sensing range with large aperture lenses.
• Sensing range (Lens on both sides) (Note 1):
3,000 mm 118.110 in (FT-B8), 2,500 mm 98.425 in (FT-FM2),
3,000 mm 118.110 in (FT-W8)
Side-view
lens
FX-SV1
Beam axis is bent by 90º.
• Sensing range (Lenses on both sides) (Note 1) :
220 mm 8.661 in (FT-B8), 200 mm 7.874 in (FT-FM2, FT-T80),
25 mm 0.984 in (FT-W8)
Pinpoint
spot lens
FX-MR1
Pinpoint spot of ø0.5 mm ø0.020 in.
• Applicable fibers: FD-WG4, FD-G4
• Distance to focal point: 6 ± 1 mm 0.236 ± 0.039 in
FX-MR2
The spot diameter is adjustable from ø0.7 to ø2 mm ø0.028 to
ø0.079 in according to how much the fiber is screwed in.
• Applicable fibers: FD-WG4, FD-G4
• Distance to focal point: 18.5 to 43 mm 0.728 to 1.693 in approx.
(Screw-in depth: 7 to 14 mm 0.276 to 0.551 in)
• Spot diameter: ø0.7 to ø2 mm ø0.028 to ø0.079 in (Screw-in
depth: 7 to 14 mm ø0.276 to ø0.551 in)
Expansion
lens
Superexpansion
lens
Zoom lens
Finest spot
lens
Digital panel
controller
(Note 2)
FX-MR3
Extremely fine spot of ø0.3 mm ø0.012 in is achieved.
• Applicable fibers: FD-WG4, FD-EG1, FD-G4
• Distance to focal point: 7.5 ± 0.5 mm 0.295 ± 0.020 in
• Spot diameter: ø0.3 mm ø0.012 in (FD-EG1),
ø0.5 mm ø0.020 in (FD-WG4, FD-G4)
CA2-T2
This is a very small controller which allows two independent
threshold level settings.
• Supply voltage: 24 V DC ± 10 %
• Output: NPN open-collector transistor
• No. of inputs: 1 No. (sensor input)
• Input range: 1 to 5 V DC
• Main functions:
Threshold level setting function, zero-adjust function,
scale setting function, hysteresis setting function, start / hold
function, auto-reference function, power supply ON-delay
function, etc.
FTP-500 (0.5 m 1.640 ft)
For
thread
FTP-1500 (1.5 m 4.921 ft)
FDP-500 (0.5 m 1.640 ft)
For
FDP-1000 (1 m 3.281 ft) M6
thread
FDP-1500 (1.5 m 4.921 ft)
FDP-N500 (0.5 m 1.640 ft)
For
FDP-N1000 (1 m 3.281 ft) M4
Fiber bender
FB-1
Universal
sensor
mounting stand
(Note 3)
MS-AJ1-F
MS-AJ2-F
• FX-LE1
• FX-LE2
Side-view lens
Pinpoint spot lens
• FX-SV1
• FX-MR1
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Zoom lens
Finest spot lens
• FX-MR2
• FX-MR3
Screw-in depth
SENSOR
OPTIONS
WIRESAVING
SYSTEMS
MEASUREMENT
SENSORS
Distance to
focal point
Spot diameter
Digital panel controller
STATIC
CONTROL
DEVICES
LASER
MARKERS
• CA2 series
Protective tube
Fiber bender
• FTP-□
• FDP-□
• FB-1
Selection
Guide
Fibers
FT-T80
FT-NFM2
FT-NFM2S
FT-NFM2S4
FD-T40
FD-B8
FD-FM2
FD-FM2S
FD-FM2S4
Universal sensor mounting stand
Using the arm which enables adjustment in
the horizontal direction, sensing can also be
done from above an assembly line.
The protective tube, made of
non-corrosive stainless steel,
protects the inner fiber cable
from any external forces.
FD-T80
FD-NFM2
FD-NFM2S
FD-NFM2S4
Forward / back
adjustment:
130 mm 5.118 in
approx.
360°
rotation
360°
rotation
20° 20°
Angle adjustment: ± 20°
FX-100
FX-300
FX-311
FX-11A
Height
adjustment:
150 mm 5.906 in
approx.
Mounting hole
for M6 screw
• MS-AJ2-F
The fiber bender bends the sleeve part of the fiber head at the
proper radius.
Horizontal mounting type Mounting stand assembly for fiber
For M3, M4 or M6 threaded
head fibers
Vertical mounting type
360°
rotation
Notes: 1) The sensing range is defined as the range until the saturation indicator lights up.
2) For further details, refer to p.793~ for the ultra-compact digital panel controller CA2 series.
3) Refer to p.799 for the universal sensor mounting stand.
Fiber
Fiber Sensor
Sensor
Amplifi
ers
Amplifiers
FX-410
• MS-AJ1-F
360°
Forward / back rotation
adjustment:
130 mm 5.118 in
approx.
thread
FDP-N1500 (1.5 m 4.921 ft)
Applicable fibers
FTP-N500 (0.5 m 1.640 ft)
For
FTP-N1000 (1 m 3.281 ft) M3
thread
FTP-N1500 (1.5 m 4.921 ft)
Protective tube
For reflective
type fiber
Super-expansion lens
FT / FD / FR
FT-B8
FT-FM2
FT-FM2S
FT-FM2S4
FTP-1000 (1 m 3.281 ft) M4
Protective tube
For thru-beam
type fiber
Expansion lens
20°
20°
Angle adjustment: ± 20°
Height
adjustment:
150 mm 5.906 in
approx.
Mounting hole
for M6 screw
FX-301-F
Other
Products
187
Slim Body Analog Fiber Sensor
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Fibers
Type
Item
Standard, small fiber head, small diameter, sharp bend, long sensing range with lens, wide beam, array,
high precision
Allowable bending radius
R25 mm R0.984 in or more [Sharp bend: R1 mm R0.039 in or more (FD-WG4, FD-WSG4: R2 mm R0.079 in or more)]
Ambient temperature
Ambient humidity
Fiber core: Acrylic
Sheath: Polyethylene
Fiber head: Brass (Nickel-plated) Threaded part of standard, threaded part of small diameter, threaded type of sharp bend,
high precision, array
PRESSURE
SENSORS
Material
Stainless steel (SUS) FT-SFM2, small fiber head, FT-SNFM2, FD-SNFM2, non-threaded type of sharp bend,
FT-SFM2L, sleeve part of sleeve-attached fiber
Polycarbonate (Lens of FT-WS8L), Norbornene resin (Lens of FT-A8)
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
All fibers: 1 fiber attachment set
Free-cut type fibers: FX-CT2 1pc. (Fiber cutter)
Threaded head fibers: nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer 1 pc. (thru-beam type: 2 pcs.)
FT-A8: 0.5 × 12 mm 0.020 × 0.472 in seal type slit mask 2 pcs. and 1 × 12 mm 0.039 × 0.472 in seal type slit mask 2 pcs.
Accessories
WIRESAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Amplifier
Model No.
Item
Supply voltage
Current consumption
Analog output
Response time
Fibers
FT / FD / FR
Fiber Sensor
Sensor
Fiber
Amplifiers
Amplifiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
Incident beam indicator
FX-11A
12 to 24 V DC ± 10 %
Ripple P-P 10 % or less
35 mA or less
Analog voltage
• Output voltage: 1 to 5 V (proportional to incident light intensity)
• Output current: 5 mA or less
• Output impedance: 47 Ω
• Load resistance: 2 kΩ or more
• Temperature characteristics: 0.3 % F.S./°C or less
Switchable either 1 ms or less, or 10 ms or less
Red LED (brightens up in proportion to analog output voltage)
Saturation indicator
Green LED (lights up when the analog output voltage reaches 5 V)
Sensitivity adjuster
8-turn potentiometer with indicator
Interference prevention function
Incorporated
Ambient temperature
–10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F
Environmental resistance
Selection
Guide
–40 to +70 °C –40 to+158 °F (Sharp bend: –40 to +60 °C –40 to +140 °F, FD-EG1: –20 to +60 °C –4 to +140 °F) (No dew condensation or icing allowed),
Storage: –40 to +70 °C –40 to +158 °F (Sharp bend: –40 to +60 °C –40 to +140 °F, FD-EG1: –20 to +60 °C –4 to +140 °F)
35 to 85 % RH, Storage: 35 to 85 % RH
SAFETY
COMPONENTS
INDUCTIVE
PROXIMITY
SENSORS
FX-11A
Ambient humidity
Ambient illuminance
Voltage withstandability
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 1,000 ℓx at the light-receiving face
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 2)
Insulation resistance
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 2)
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance
Emitting element
Material
Cable
Cable extension
Weight
Accessories
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Red LED (Peak emission wavelength: 660 nm 0.026 mil, modulated)
Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Fiber lock lever: PES
0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 3)
Net weight: 60 g approx., Gross weight: 100 g approx.
MS-DIN-2 (Amplifier mounting bracket): 1 pc., Adjusting screwdriver: 1 pc.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
3) Take care that the output voltage drops when the cable is extended.
Slim Body Analog Fiber Sensor
188
FX-11A
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
I/O circuit diagram
Wiring diagram
LASER
SENSORS
Color code
Sensor circuit
D1
+7 V
+
–
D2 47 Ω
(Brown) Analog voltage output (Note)
D3
(Orange / Violet)
Interference
prevention wire
(Blue) 0 V
+
Internal circuit
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Brown
(Brown) +V
Black
12 to 24 V DC
± 10 %
Load
–
Load resistance
2 kΩ or more
+
–
Orange / Violet
Load
To the other amplifier’s
interference prevention wire
Blue
12 to 24 V DC
± 10 %
SAFETY
COMPONENTS
Users’ circuit
PRESSURE
SENSORS
Symbols...D1: Reverse supply polarity protection diode
D2, D3: Surge absorption diode
INDUCTIVE
PROXIMITY
SENSORS
Note: The analog voltage output is not incorporated with a short-circuit protection
circuit. Do not connect it directly to a power supply or a capacitive load.
SENSING CHARACTERISTICS (TYPICAL)
PARTICULAR
USE
SENSORS
The sensing characteristics for the thru-beam type and reflective type are
listed in alphabetic order respectively.
FT-B8
8
8
8
Fiber head
Fiber head
Maximum
sensitivity
4
2
6
Fiber head
4
Maximum
sensitivity
2
Half sensitivity
8
Thru-beam type
FT-W4
L
Fiber head
4
Maximum
sensitivity
2
6
2
0
Fiber head
Maximum
sensitivity
4
2
Output voltage (V)
L
6
FT-WS4
L
Fiber head
4
Maximum
sensitivity
2
2
100
200
300
400
3.937
7.874 11.811 15.748
Setting distance L (mm in)
600
400
800 1,000
200
7.874 15.748 23.622 31.496 39.370
Setting distance L (mm in)
Selection
Guide
FT-W8 FT-WS8 Thru-beam type
Thru-beam type
L
Fiber head
4
Maximum
sensitivity
2
Fiber head
Fiber head
Reflective type
8
6
L
Fiber head
4
Maximum
sensitivity
2
FX-301-F
100
200
300
400
3.937
7.874 11.811 15.748
Setting distance L (mm in)
Reflective type
8
50 × 50 mm 1.969 × 1.969 in
White non-glossy paper
6
L
Fiber head
4
Maximum
sensitivity
2
Half sensitivity
Half sensitivity
0
FX-311
Other
200
400
600
800 Products
7.874 15.748 23.622 31.496
Setting distance L (mm in)
FD-EG1
100 × 100 mm 3.937 × 3.937 in
White non-glossy paper
0
FX-300
FX-11A
2
0
200
7.874
FT / FD / FR
Fiber
Fiber Sensor
Sensor
Amplifi
ers
Amplifiers
FX-410
Maximum
sensitivity
4
Fibers
FX-100
L
6
Half sensitivity
50
100
150
1.969
3.937
5.906
Setting distance L (mm in)
FD-B8
Half sensitivity
0
Maximum
sensitivity
8
6
0
50 × 50 mm 1.969 × 1.969 in
White non-glossy paper
6
Half sensitivity
500
1,000
1,500
2,000
19.685 39.370 59.055 78.740
Setting distance L (mm in)
500
1,000
1,500
2,000
19.685 39.370 59.055 78.740
Setting distance L (mm in)
8
Fiber head
Fiber head
4
Half sensitivity
FD-AFM2 FD-AFM2E Reflective type
Thru-beam type
8
Maximum
sensitivity
LASER
MARKERS
L
Fiber head
Half sensitivity
100
200
300
400
3.937
7.874 11.811 15.748
Setting distance L (mm in)
FT-WS8L
L
Fiber head
4
6
0
8
Output voltage (V)
6
STATIC
CONTROL
DEVICES
Half sensitivity
500
1,000
1,500
2,000
19.685 39.370 59.055 78.740
Setting distance L (mm in)
Fiber head
Output voltage (V)
Output voltage (V)
0
8
Half sensitivity
Output voltage (V)
2
MEASUREMENT
SENSORS
Fiber head
Half sensitivity
Fiber head
0
Fiber head
Maximum
sensitivity
200
400
600
800
7.874 15.748 23.622 31.496
Setting distance L (mm in)
FT-SFM2L
L
4
Half sensitivity
0
1,000
2,000
3,000
4,000
39.370 78.740 118.110 157.480
Setting distance L (mm in)
FT-NFM2 FT-NFM2S
Thru-beam
FT-NFM2S4 FT-SNFM2 type
0
6
Output voltage (V)
0
L
Output voltage (V)
6
Output voltage (V)
Output voltage (V)
Fiber head
L
Output voltage (V)
Fiber head
FT-FM2 FT-FM2S FT-FM2S4 Thru-beam
type
FT-SFM2 FT-T80
Thru-beam type
Output voltage (V)
8
FT-AFM2 FT-AFM2E Thru-beam type
Output voltage (V)
Thru-beam type
SENSOR
OPTIONS
WIRESAVING
SYSTEMS
Correlation between setting distance and output voltage
FT-A8
AREA
SENSORS
10
20
30
0.394
0.787
1.811
Setting distance L (mm in)
40
1.575
189
Slim Body Analog Fiber Sensor
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
PRESSURE
SENSORS
8
8
6
L
Fiber head
4
Maximum
sensitivity
2
2
8
8
6
L
Fiber head
4
Maximum
sensitivity
2
6
200
7.874
0
L
Fiber head
4
Maximum
sensitivity
2
Half sensitivity
50
100
150
1.969
3.937
5.906
Setting distance L (mm in)
Reflective
type
50 × 50 mm 1.969 × 1.969 in
White non-glossy paper
50 × 50 mm 1.969 × 1.969 in
White non-glossy paper
Half sensitivity
0
100
200
300
400
3.937
7.874 11.811 15.748
Setting distance L (mm in)
8
Output voltage (V)
LASER
MARKERS
Maximum
sensitivity
FD-W8 FD-WT8
FD-WS8
Half sensitivity
50
100
150
1.969
3.937
5.906
Setting distance L (mm in)
200
7.874
0
50
100
150
1.969
3.937
5.906
Setting distance L (mm in)
200
7.874
FD-WG4 FD-WSG4 Reflective type
WIRESAVING
SYSTEMS
STATIC
CONTROL
DEVICES
L
Fiber head
Half sensitivity
0
PARTICULAR
USE
SENSORS
MEASUREMENT
SENSORS
6
4
FD-NFM2 FD-NFM2S FD-T40 Reflective
type
FD-NFM2S4 FD-SNFM2
50 × 50 mm 1.969 × 1.969 in
White non-glossy paper
50 × 50 mm 1.969 × 1.969 in
White non-glossy paper
INDUCTIVE
PROXIMITY
SENSORS
SENSOR
OPTIONS
Reflective type
Output voltage (V)
SAFETY
COMPONENTS
FD-G4
Output voltage (V)
AREA
SENSORS
FD-FM2 FD-FM2S
Reflective
FD-FM2S4 FD-S80 FD-T80 type
Output voltage (V)
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Correlation between setting distance and output voltage
Output voltage (V)
LASER
SENSORS
FX-11A
50 × 50 mm 1.969 × 1.969 in
White non-glossy paper
6
L
Fiber head
4
Maximum
sensitivity
2
Half sensitivity
20
40
60
0.787
1.575
2.362
Setting distance L (mm in)
0
80
3.150
Correlation between setting distance and output voltage when using seal type slit masks
FT-A8
8
FT / FD / FR
FX-100
FX-300
FX-410
FX-311
Output voltage (V)
Fiber Sensor
Sensor
Fiber
Amplifiers
Amplifiers
FX-301-F
Other
Products
8
Fiber head
L
6
Fiber head
Maximum
sensitivity
4
2
FX-11A
With slit mask (0.5 × 12 mm 0.020 × 0.472 in)
on both sides
0
500
1,000
1,500
2,000
19.685 39.370 59.055 78.740
Setting distance L (mm in)
8
Fiber head
L
6
Fiber head
Maximum
sensitivity
4
2
Half sensitivity
With slit mask (1 × 12 mm 0.020 × 0.472 in)
on one side
6
200 400
600
800 1,000
7.874 15.748 23.622 31.496 39.370
Setting distance L (mm in)
8
Fiber head
Maximum
sensitivity
L
Fiber head
4
2
0
500
1,000
1,500
2,000
19.685 39.370 59.055 78.740
Setting distance L (mm in)
Fiber head
L
6
Fiber head
Maximum
sensitivity
4
2
Half sensitivity
Half sensitivity
0
With slit masks (1 × 12 mm 0.020 × 0.472 in)
on both sides
Output voltage (V)
With slit masks (0.5 × 12 mm 0.020 × 0.472 in)
on one side
Output voltage (V)
Fibers
Thru-beam type
Output voltage (V)
Selection
Guide
Half sensitivity
0
500
1,000
1,500
2,000
19.685 39.370 59.055 78.740
Setting distance L (mm in)
Slim Body Analog Fiber Sensor
PRECAUTIONS FOR PROPER USE
FX-11A
190
Refer to p.986~ for general precautions and p.105 for precautions of fibers.
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Others
LASER
SENSORS
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
• The analog output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power
supply or a capacitive load.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
Response time selection
• The response time of FX-11A can be selected either
“1 ms” or “10 ms”. If your detecting application does not
need a quick response, “10 ms” is recommended as
it makes the detection secure against inductive noise
and ambient light. If you choose “1 ms”, pay attention to
electromagnetic noise and ambient light.
• The response time of FX-11A is the time required for the
output voltage to rise from 1 V (dark state voltage) to
[90 % of {light state voltage – 1 V (dark state voltage)}
+ 1 V (dark state voltage)] or the time required for the
output voltage to fall from the light state voltage to [10 %
of {light state voltage – 1 V (dark state voltage)} + 1 V
(dark state voltage)]. The response time of FX-11A is
constant regardless of the amplitude of the output voltage.
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRESAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
(e.g.)
4 V (Light state)
3.7 V
LASER
MARKERS
3V
(Light state)
2.8 V
1.3V
1 V (Dark state)
t1
t1
FIBER
SENSORS
t2
1.2 V
1V
(Dark state)
t2
t1 = t2: Response time
DIMENSIONS (Unit: mm in)
Refer to p.106~ for dimensions other than those given in the figures below.
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.com
FX-11A
Amplifier
MS-DIN-2
Amplifier mounting bracket (Accessory for FX-11A)
Assembly dimensions with attached amplifier mounting bracket
Interference prevention selection switch
Response time selection switch
Incident beam indicator (Red)
Sensitivity adjuster (8-turn)
3.2
0.126
Fiber lock lever
10
0.394
10 0.394
8
0.315
22
0.866
21.9
0.862
59
2.323
7.5
0.295
3
0.118
60
2.362
Beamreceiving
part
2.4
0.094
0.4
0.016
ø1.8
ø0.071
ø4.2 ø0.165 cable,
2 m 6.562 ft long
31.5
1.240
3
Beam0.118
emitting
part
ø8.6
9 ø0.339
0.354
4.5 0.177
11.6
2-ø3.2 ø0.126 holes 0.457
Suitable for 35 mm 1.378 in width DIN rail
3.2 0.126
21.1
0.831
36.5
1.437
16
0.630
Note: The top view is shown without the cover.
2 0.079
Attached amplifier mounting
bracket (MS-DIN-2)
2
0.079
5.2
0.205 3.2
0.126
35
1.378
2 0.079
Malerial: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
FX-300
FX-410
FX-11A
t1
t 0.039
27
1.063
FX-100
FX-311
2
0.079
7.5
0.295 4.2 0.165
2-ø3.2 ø0.126 holes
Fiber
Fiber Sensor
Sensor
Amplifi
ers
Amplifiers
10
5 0.197 0.394
8.5 5.2 0.205
0.335
Fibers
FT / FD / FR
21.6
0.850
16
0.630
Saturation indicator (Green)
Selection
Guide
FX-301-F
Other
Products