FX-11A

FX-11A

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    SENSOR ANALOG 1-5V 12-24VDC

  • 数据手册
  • 价格&库存
FX-11A 数据手册
183 FIBER SENSORS Slim Body Analog Fiber Sensor FX-11A Related Information ■ General terms and conditions............. P.1 ■ Glossary of terms.......................... P.983~ ■ Sensor selection guide .......P.11~ / P.61~ ■ General precautions...................... P.986~ LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY COMPONENTS PRESSURE SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS SUNX website http://www.sunx.com STATIC CONTROL DEVICES LASER MARKERS Selection Guide Fibers FT / FD / FR Fiber Sensor Amplifiers Amplifi ers Interference prevention Analog output type for diverse applications Analog voltage output Slim size It incorporates an analog voltage output of 1 to 5 V. Being only 10 mm 0.394 in thick, it can be mounted in a narrow space. Various uses In combination with various types of fibers and the ultracompact digital panel controller, CA2 series, FX-11A can be used for various applications, such as, height evaluation, level detection by differential sensing, etc. Only 10 mm 0.394 in thick 10 mm 0.394 in FX-100 FX-300 Saturation indicator FX-410 FX-311 FX-11A FX-301-F Other Products CA2 series (Refer to p.793~.) Digital panel controller Interference prevention function Two sets of fibers can be mounted close together or face to face. The saturation indicator lights up when the output reaches 5 V. Hence, the sensitivity can be easily adjusted even without using a tester. Moreover, an incident beam indicator which brightens up in proportion to the amount of incident beam (output voltage) is also incorporated. Incident beam indicator (Red) Saturation indicator (Green) Slim Body Analog Fiber Sensor ORDER GUIDE SPECIFICATIONS P.184~ P.187 I/O CIRCUIT DIAGRAMS SENSING CHARACTERISTICS PRECAUTIONS FOR PROPER USE P.188 P.188~ FX-11A DIMENSIONS P.190 184 P.190 APPLICATIONS FIBER SENSORS Detecting level difference Ascertaining the number of translucent films Measuring inner diameter of rings When differential sensing is used, no sensitivity readjustment is required even if the reflectivity of the objects changes. The number of overlapping translucent films can be ascertained. Rings can be sorted according to their inner diameter. LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY COMPONENTS PRESSURE SENSORS INDUCTIVE PROXIMITY SENSORS ORDER GUIDE PARTICULAR USE SENSORS Accessory Amplifier Appearance Model No. FX-11A Supply voltage Analog output 12 to 24 V DC ± 10 % Analog voltage • Output voltage: 1 to 5 V • MS-DIN-2 (Amplifier mounting bracket) Shape of fiber head (mm in) Long sensing range Lens mountable STATIC CONTROL DEVICES LASER MARKERS Sensing range (Note 1,2) 160 mm 6.299 in 125 mm 4.921 in M4 With lens ø2.5 ø0.098 Lens mountable Features Fiber cable length : free cut • Twice the sensing range for the same diameter 2 m 6.562 ft • Long sensing range with small fiber heads of ø2.5 mm ø0.098 in 2 m 6.562 ft M4 85 mm 3.346 in M4 ø1.48 ø0.058 • Free-cut type With sleeve 90 mm 3.543 in 2 m 6.562 ft Standard 85 mm 3.346 in • Miniature head but having the same sensing range as the standard type fiber 2 m 6.562 ft Thru-beam M3 ø0.88 ø0.035 • Suitable for detection in a congested equipment • Free-cut type 23 mm 0.906 in 2 m 6.562 ft Long sensing Wide beam Small diameter Standard range Array Sharp bend M4 M3 ø1.5 ø0.059 Sensing width 11 mm 0.433 in 8 mm 0.315 in FT-W4 • The wide beam detects an object at any place within the range. 2 m 6.562 ft • The wide beam detects an object at any place within the range. 2 m 6.562 ft 15 0.591 Side sensing 15 0.591 FT-WS8 FT-WS4 100 mm 3.937 in W4.2 × H31 × D13.5 W0.165 × H1.220 × D0.531 FT-W8 2 m 6.562 ft 65 mm 2.559 in FX-100 FX-300 FX-410 FT-NFM2S4 FT-WS8L • The fiber can be bent sharply, like an electric wire, to avoid space wastage in installation because of its small allowable bending radius of R1 mm R0.039 in or more. 35 mm 1.378 in FT / FD / FR Fiber Fiber Sensor Sensor Amplifi ers Amplifiers FX-311 With sleeve 40 mm 1.575 in 100 mm 3.937 in Fibers FX-11A FT-SNFM2 ø3 ø0.118 Selection Guide FT-NFM2S With sleeve 90 mm 3.543 in ø1.5 ø0.059 ø2.5 ø0.098 FT-T80 FT-NFM2 With sleeve Special use FT-FM2S4 FT-SFM2 M3 Top sensing FT-SFM2L With sleeve 40 mm 1.575 in M3 Lens mountable FT-B8 FT-FM2S ø2.5 ø0.098 With lens Model No. FT-FM2 With sleeve Lens mountable WIRESAVING SYSTEMS MEASUREMENT SENSORS Fibers [Thru-beam type (one pair set)] Type SENSOR OPTIONS FT-A8 FT-AFM2 FT-AFM2E Notes: 1) The sensing range is defined as the range until the saturation indicator lights up. 2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. FX-301-F Other Products 185 Slim Body Analog Fiber Sensor ORDER GUIDE FIBER SENSORS LASER SENSORS Fibers [Reflective type] PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Shape of fiber head (mm in) Long sensing range Type AREA SENSORS 31 mm 1.220 in M6 Standard SENSOR OPTIONS M3 Small diameter ø3 ø0.118 WIRESAVING SYSTEMS Reflective ø1.48 ø0.058 Standard High precision Sharp bend M6 Other Products FD-T80 • Miniature head but having the same sensing range as the standard type fiber 7 mm 0.276 in 22 mm 0.866 in FD-T40 2 m 6.562 ft FD-S80 • Suitable for detection in a congested equipment • Free-cut type 7 mm 0.276 in 2 m 6.562 ft FD-NFM2S With sleeve 90 mm 3.543 in FD-NFM2S4 With sleeve 40 mm 1.575 in FD-SNFM2 8 mm 0.315 in FD-W8 M4 ø3 ø0.118 • The fiber can be bent sharply, like an electric wire, to avoid space wastage in installation because of its small allowable bending radius of R1 mm R0.039 in or more (FD-WG4, FD-WSG4: R2 mm R0.079 in or more). 8 mm 0.315 in Coaxial M4 Lens mountable Coaxial ø3 ø0.118 3 mm 0.118 in FD-WT8 2 m 6.562 ft FD-WS8 FD-WG4 FD-WSG4 Top sensing 20 0.787 Side sensing 20 High precision Special use Array FD-AFM2 FT / FD / FR FX-301-F FD-FM2S With sleeve 90 mm 3.543 in FD-FM2S4 With sleeve 40 mm 1.575 in ø2.5 ø0.098 Fibers FX-11A 2 m 6.562 ft FD-NFM2 With sleeve M4 Selection Guide FX-311 • Free-cut type M4 MEASUREMENT SENSORS FX-410 FD-B8 22 mm 0.866 in M4 PARTICULAR USE SENSORS FX-300 Model No. 2 m 6.562 ft ø2.5 ø0.098 INDUCTIVE PROXIMITY SENSORS FX-100 Fiber cable length : free cut FD-FM2 M6 Fiber Sensor Sensor Fiber Amplifiers Amplifiers Features • Long sensing range 22 mm 0.866 in With sleeve PRESSURE SENSORS LASER MARKERS Sensing range (Note 1,2) Coaxial M6 SAFETY COMPONENTS STATIC CONTROL DEVICES FX-11A 13 mm 0.512 in • Its wide beam meets various needs. 2 m 6.562 ft FD-AFM2E 0.787 Coaxial M4 Lens mountable Coaxial • Small head M3 Lens mountable 10 mm 0.394 in • Precise position sensing with coaxial fiber • Combination with the FX-MR3 lens gives an extremely small spot diameter of ø0.3 mm ø0.012 in approx. 3 mm 0.118 in 2 m 6.562 ft 500 mm 19.685 in Notes: 1) The sensing range is defined as the range until the saturation indicator lights up. Further, for the reflective type fibers, it is specified for white non-glossy paper [50 × 50 mm 1.969 × 1.969 in (FD-B8: 100 × 100 mm 3.937 × 3.937 in)] as the object. 2) Please take care that the sensing range of free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. Accessories • FX-CT2 (Fiber cutter) • FX-AT10 (ø1 mm ø0.039 in fiber attachment) • FX-AT13 (ø1.3 mm ø0.051 in fiber attachment) • FX-CT2 • FX-AT10 • FX-AT13 FD-G4 FD-EG1 Slim Body Analog Fiber Sensor FX-11A 186 OPTIONS For reflective type fiber For thru-beam type fiber Designation FIBER SENSORS Model No. Description FX-LE1 Increases the sensing range by 6 times or more. • Sensing range (Lens on both sides) (Note 1): 900 mm 35.433 in (FT-B8), 750 mm 29.528 in (FT-FM2, FT-T80), 350 mm 13.780 in (FT-W8) FX-LE2 Tremendously increases the sensing range with large aperture lenses. • Sensing range (Lens on both sides) (Note 1): 3,000 mm 118.110 in (FT-B8), 2,500 mm 98.425 in (FT-FM2), 3,000 mm 118.110 in (FT-W8) Side-view lens FX-SV1 Beam axis is bent by 90º. • Sensing range (Lenses on both sides) (Note 1) : 220 mm 8.661 in (FT-B8), 200 mm 7.874 in (FT-FM2, FT-T80), 25 mm 0.984 in (FT-W8) Pinpoint spot lens FX-MR1 Pinpoint spot of ø0.5 mm ø0.020 in. • Applicable fibers: FD-WG4, FD-G4 • Distance to focal point: 6 ± 1 mm 0.236 ± 0.039 in FX-MR2 The spot diameter is adjustable from ø0.7 to ø2 mm ø0.028 to ø0.079 in according to how much the fiber is screwed in. • Applicable fibers: FD-WG4, FD-G4 • Distance to focal point: 18.5 to 43 mm 0.728 to 1.693 in approx. (Screw-in depth: 7 to 14 mm 0.276 to 0.551 in) • Spot diameter: ø0.7 to ø2 mm ø0.028 to ø0.079 in (Screw-in depth: 7 to 14 mm ø0.276 to ø0.551 in) Expansion lens Superexpansion lens Zoom lens Finest spot lens Digital panel controller (Note 2) FX-MR3 Extremely fine spot of ø0.3 mm ø0.012 in is achieved. • Applicable fibers: FD-WG4, FD-EG1, FD-G4 • Distance to focal point: 7.5 ± 0.5 mm 0.295 ± 0.020 in • Spot diameter: ø0.3 mm ø0.012 in (FD-EG1), ø0.5 mm ø0.020 in (FD-WG4, FD-G4) CA2-T2 This is a very small controller which allows two independent threshold level settings. • Supply voltage: 24 V DC ± 10 % • Output: NPN open-collector transistor • No. of inputs: 1 No. (sensor input) • Input range: 1 to 5 V DC • Main functions: Threshold level setting function, zero-adjust function, scale setting function, hysteresis setting function, start / hold function, auto-reference function, power supply ON-delay function, etc. FTP-500 (0.5 m 1.640 ft) For thread FTP-1500 (1.5 m 4.921 ft) FDP-500 (0.5 m 1.640 ft) For FDP-1000 (1 m 3.281 ft) M6 thread FDP-1500 (1.5 m 4.921 ft) FDP-N500 (0.5 m 1.640 ft) For FDP-N1000 (1 m 3.281 ft) M4 Fiber bender FB-1 Universal sensor mounting stand (Note 3) MS-AJ1-F MS-AJ2-F • FX-LE1 • FX-LE2 Side-view lens Pinpoint spot lens • FX-SV1 • FX-MR1 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY COMPONENTS PRESSURE SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Zoom lens Finest spot lens • FX-MR2 • FX-MR3 Screw-in depth SENSOR OPTIONS WIRESAVING SYSTEMS MEASUREMENT SENSORS Distance to focal point Spot diameter Digital panel controller STATIC CONTROL DEVICES LASER MARKERS • CA2 series Protective tube Fiber bender • FTP-□ • FDP-□ • FB-1 Selection Guide Fibers FT-T80 FT-NFM2 FT-NFM2S FT-NFM2S4 FD-T40 FD-B8 FD-FM2 FD-FM2S FD-FM2S4 Universal sensor mounting stand Using the arm which enables adjustment in the horizontal direction, sensing can also be done from above an assembly line. The protective tube, made of non-corrosive stainless steel, protects the inner fiber cable from any external forces. FD-T80 FD-NFM2 FD-NFM2S FD-NFM2S4 Forward / back adjustment: 130 mm 5.118 in approx. 360° rotation 360° rotation 20° 20° Angle adjustment: ± 20° FX-100 FX-300 FX-311 FX-11A Height adjustment: 150 mm 5.906 in approx. Mounting hole for M6 screw • MS-AJ2-F The fiber bender bends the sleeve part of the fiber head at the proper radius. Horizontal mounting type Mounting stand assembly for fiber For M3, M4 or M6 threaded head fibers Vertical mounting type 360° rotation Notes: 1) The sensing range is defined as the range until the saturation indicator lights up. 2) For further details, refer to p.793~ for the ultra-compact digital panel controller CA2 series. 3) Refer to p.799 for the universal sensor mounting stand. Fiber Fiber Sensor Sensor Amplifi ers Amplifiers FX-410 • MS-AJ1-F 360° Forward / back rotation adjustment: 130 mm 5.118 in approx. thread FDP-N1500 (1.5 m 4.921 ft) Applicable fibers FTP-N500 (0.5 m 1.640 ft) For FTP-N1000 (1 m 3.281 ft) M3 thread FTP-N1500 (1.5 m 4.921 ft) Protective tube For reflective type fiber Super-expansion lens FT / FD / FR FT-B8 FT-FM2 FT-FM2S FT-FM2S4 FTP-1000 (1 m 3.281 ft) M4 Protective tube For thru-beam type fiber Expansion lens 20° 20° Angle adjustment: ± 20° Height adjustment: 150 mm 5.906 in approx. Mounting hole for M6 screw FX-301-F Other Products 187 Slim Body Analog Fiber Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Fibers Type Item Standard, small fiber head, small diameter, sharp bend, long sensing range with lens, wide beam, array, high precision Allowable bending radius R25 mm R0.984 in or more [Sharp bend: R1 mm R0.039 in or more (FD-WG4, FD-WSG4: R2 mm R0.079 in or more)] Ambient temperature Ambient humidity Fiber core: Acrylic Sheath: Polyethylene Fiber head: Brass (Nickel-plated) Threaded part of standard, threaded part of small diameter, threaded type of sharp bend, high precision, array PRESSURE SENSORS Material Stainless steel (SUS) FT-SFM2, small fiber head, FT-SNFM2, FD-SNFM2, non-threaded type of sharp bend, FT-SFM2L, sleeve part of sleeve-attached fiber Polycarbonate (Lens of FT-WS8L), Norbornene resin (Lens of FT-A8) PARTICULAR USE SENSORS SENSOR OPTIONS All fibers: 1 fiber attachment set Free-cut type fibers: FX-CT2 1pc. (Fiber cutter) Threaded head fibers: nuts 2 pcs. (thru-beam type: 4 pcs.) and toothed lock washer 1 pc. (thru-beam type: 2 pcs.) FT-A8: 0.5 × 12 mm 0.020 × 0.472 in seal type slit mask 2 pcs. and 1 × 12 mm 0.039 × 0.472 in seal type slit mask 2 pcs. Accessories WIRESAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS Amplifier Model No. Item Supply voltage Current consumption Analog output Response time Fibers FT / FD / FR Fiber Sensor Sensor Fiber Amplifiers Amplifiers FX-100 FX-300 FX-410 FX-311 FX-11A FX-301-F Other Products Incident beam indicator FX-11A 12 to 24 V DC ± 10 % Ripple P-P 10 % or less 35 mA or less Analog voltage • Output voltage: 1 to 5 V (proportional to incident light intensity) • Output current: 5 mA or less • Output impedance: 47 Ω • Load resistance: 2 kΩ or more • Temperature characteristics: 0.3 % F.S./°C or less Switchable either 1 ms or less, or 10 ms or less Red LED (brightens up in proportion to analog output voltage) Saturation indicator Green LED (lights up when the analog output voltage reaches 5 V) Sensitivity adjuster 8-turn potentiometer with indicator Interference prevention function Incorporated Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F Environmental resistance Selection Guide –40 to +70 °C –40 to+158 °F (Sharp bend: –40 to +60 °C –40 to +140 °F, FD-EG1: –20 to +60 °C –4 to +140 °F) (No dew condensation or icing allowed), Storage: –40 to +70 °C –40 to +158 °F (Sharp bend: –40 to +60 °C –40 to +140 °F, FD-EG1: –20 to +60 °C –4 to +140 °F) 35 to 85 % RH, Storage: 35 to 85 % RH SAFETY COMPONENTS INDUCTIVE PROXIMITY SENSORS FX-11A Ambient humidity Ambient illuminance Voltage withstandability 35 to 85 % RH, Storage: 35 to 85 % RH Incandescent light: 1,000 ℓx at the light-receiving face 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 2) Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 2) Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance Emitting element Material Cable Cable extension Weight Accessories 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each Red LED (Peak emission wavelength: 660 nm 0.026 mil, modulated) Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, Fiber lock lever: PES 0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 3) Net weight: 60 g approx., Gross weight: 100 g approx. MS-DIN-2 (Amplifier mounting bracket): 1 pc., Adjusting screwdriver: 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. 3) Take care that the output voltage drops when the cable is extended. Slim Body Analog Fiber Sensor 188 FX-11A I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS I/O circuit diagram Wiring diagram LASER SENSORS Color code Sensor circuit D1 +7 V + – D2 47 Ω (Brown) Analog voltage output (Note) D3 (Orange / Violet) Interference prevention wire (Blue) 0 V + Internal circuit PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Brown (Brown) +V Black 12 to 24 V DC ± 10 % Load – Load resistance 2 kΩ or more + – Orange / Violet Load To the other amplifier’s interference prevention wire Blue 12 to 24 V DC ± 10 % SAFETY COMPONENTS Users’ circuit PRESSURE SENSORS Symbols...D1: Reverse supply polarity protection diode D2, D3: Surge absorption diode INDUCTIVE PROXIMITY SENSORS Note: The analog voltage output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. SENSING CHARACTERISTICS (TYPICAL) PARTICULAR USE SENSORS The sensing characteristics for the thru-beam type and reflective type are listed in alphabetic order respectively. FT-B8 8 8 8 Fiber head Fiber head Maximum sensitivity 4 2 6 Fiber head 4 Maximum sensitivity 2 Half sensitivity 8 Thru-beam type FT-W4 L Fiber head 4 Maximum sensitivity 2 6 2 0 Fiber head Maximum sensitivity 4 2 Output voltage (V) L 6 FT-WS4 L Fiber head 4 Maximum sensitivity 2 2 100 200 300 400 3.937 7.874 11.811 15.748 Setting distance L (mm in) 600 400 800 1,000 200 7.874 15.748 23.622 31.496 39.370 Setting distance L (mm in) Selection Guide FT-W8 FT-WS8 Thru-beam type Thru-beam type L Fiber head 4 Maximum sensitivity 2 Fiber head Fiber head Reflective type 8 6 L Fiber head 4 Maximum sensitivity 2 FX-301-F 100 200 300 400 3.937 7.874 11.811 15.748 Setting distance L (mm in) Reflective type 8 50 × 50 mm 1.969 × 1.969 in White non-glossy paper 6 L Fiber head 4 Maximum sensitivity 2 Half sensitivity Half sensitivity 0 FX-311 Other 200 400 600 800 Products 7.874 15.748 23.622 31.496 Setting distance L (mm in) FD-EG1 100 × 100 mm 3.937 × 3.937 in White non-glossy paper 0 FX-300 FX-11A 2 0 200 7.874 FT / FD / FR Fiber Fiber Sensor Sensor Amplifi ers Amplifiers FX-410 Maximum sensitivity 4 Fibers FX-100 L 6 Half sensitivity 50 100 150 1.969 3.937 5.906 Setting distance L (mm in) FD-B8 Half sensitivity 0 Maximum sensitivity 8 6 0 50 × 50 mm 1.969 × 1.969 in White non-glossy paper 6 Half sensitivity 500 1,000 1,500 2,000 19.685 39.370 59.055 78.740 Setting distance L (mm in) 500 1,000 1,500 2,000 19.685 39.370 59.055 78.740 Setting distance L (mm in) 8 Fiber head Fiber head 4 Half sensitivity FD-AFM2 FD-AFM2E Reflective type Thru-beam type 8 Maximum sensitivity LASER MARKERS L Fiber head Half sensitivity 100 200 300 400 3.937 7.874 11.811 15.748 Setting distance L (mm in) FT-WS8L L Fiber head 4 6 0 8 Output voltage (V) 6 STATIC CONTROL DEVICES Half sensitivity 500 1,000 1,500 2,000 19.685 39.370 59.055 78.740 Setting distance L (mm in) Fiber head Output voltage (V) Output voltage (V) 0 8 Half sensitivity Output voltage (V) 2 MEASUREMENT SENSORS Fiber head Half sensitivity Fiber head 0 Fiber head Maximum sensitivity 200 400 600 800 7.874 15.748 23.622 31.496 Setting distance L (mm in) FT-SFM2L L 4 Half sensitivity 0 1,000 2,000 3,000 4,000 39.370 78.740 118.110 157.480 Setting distance L (mm in) FT-NFM2 FT-NFM2S Thru-beam FT-NFM2S4 FT-SNFM2 type 0 6 Output voltage (V) 0 L Output voltage (V) 6 Output voltage (V) Output voltage (V) Fiber head L Output voltage (V) Fiber head FT-FM2 FT-FM2S FT-FM2S4 Thru-beam type FT-SFM2 FT-T80 Thru-beam type Output voltage (V) 8 FT-AFM2 FT-AFM2E Thru-beam type Output voltage (V) Thru-beam type SENSOR OPTIONS WIRESAVING SYSTEMS Correlation between setting distance and output voltage FT-A8 AREA SENSORS 10 20 30 0.394 0.787 1.811 Setting distance L (mm in) 40 1.575 189 Slim Body Analog Fiber Sensor SENSING CHARACTERISTICS (TYPICAL) FIBER SENSORS PRESSURE SENSORS 8 8 6 L Fiber head 4 Maximum sensitivity 2 2 8 8 6 L Fiber head 4 Maximum sensitivity 2 6 200 7.874 0 L Fiber head 4 Maximum sensitivity 2 Half sensitivity 50 100 150 1.969 3.937 5.906 Setting distance L (mm in) Reflective type 50 × 50 mm 1.969 × 1.969 in White non-glossy paper 50 × 50 mm 1.969 × 1.969 in White non-glossy paper Half sensitivity 0 100 200 300 400 3.937 7.874 11.811 15.748 Setting distance L (mm in) 8 Output voltage (V) LASER MARKERS Maximum sensitivity FD-W8 FD-WT8 FD-WS8 Half sensitivity 50 100 150 1.969 3.937 5.906 Setting distance L (mm in) 200 7.874 0 50 100 150 1.969 3.937 5.906 Setting distance L (mm in) 200 7.874 FD-WG4 FD-WSG4 Reflective type WIRESAVING SYSTEMS STATIC CONTROL DEVICES L Fiber head Half sensitivity 0 PARTICULAR USE SENSORS MEASUREMENT SENSORS 6 4 FD-NFM2 FD-NFM2S FD-T40 Reflective type FD-NFM2S4 FD-SNFM2 50 × 50 mm 1.969 × 1.969 in White non-glossy paper 50 × 50 mm 1.969 × 1.969 in White non-glossy paper INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS Reflective type Output voltage (V) SAFETY COMPONENTS FD-G4 Output voltage (V) AREA SENSORS FD-FM2 FD-FM2S Reflective FD-FM2S4 FD-S80 FD-T80 type Output voltage (V) PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Correlation between setting distance and output voltage Output voltage (V) LASER SENSORS FX-11A 50 × 50 mm 1.969 × 1.969 in White non-glossy paper 6 L Fiber head 4 Maximum sensitivity 2 Half sensitivity 20 40 60 0.787 1.575 2.362 Setting distance L (mm in) 0 80 3.150 Correlation between setting distance and output voltage when using seal type slit masks FT-A8 8 FT / FD / FR FX-100 FX-300 FX-410 FX-311 Output voltage (V) Fiber Sensor Sensor Fiber Amplifiers Amplifiers FX-301-F Other Products 8 Fiber head L 6 Fiber head Maximum sensitivity 4 2 FX-11A With slit mask (0.5 × 12 mm 0.020 × 0.472 in) on both sides 0 500 1,000 1,500 2,000 19.685 39.370 59.055 78.740 Setting distance L (mm in) 8 Fiber head L 6 Fiber head Maximum sensitivity 4 2 Half sensitivity With slit mask (1 × 12 mm 0.020 × 0.472 in) on one side 6 200 400 600 800 1,000 7.874 15.748 23.622 31.496 39.370 Setting distance L (mm in) 8 Fiber head Maximum sensitivity L Fiber head 4 2 0 500 1,000 1,500 2,000 19.685 39.370 59.055 78.740 Setting distance L (mm in) Fiber head L 6 Fiber head Maximum sensitivity 4 2 Half sensitivity Half sensitivity 0 With slit masks (1 × 12 mm 0.020 × 0.472 in) on both sides Output voltage (V) With slit masks (0.5 × 12 mm 0.020 × 0.472 in) on one side Output voltage (V) Fibers Thru-beam type Output voltage (V) Selection Guide Half sensitivity 0 500 1,000 1,500 2,000 19.685 39.370 59.055 78.740 Setting distance L (mm in) Slim Body Analog Fiber Sensor PRECAUTIONS FOR PROPER USE FX-11A 190 Refer to p.986~ for general precautions and p.105 for precautions of fibers. • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Others LASER SENSORS • Do not use during the initial transient time (50 ms) after the power supply is switched on. • The analog output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY COMPONENTS Response time selection • The response time of FX-11A can be selected either “1 ms” or “10 ms”. If your detecting application does not need a quick response, “10 ms” is recommended as it makes the detection secure against inductive noise and ambient light. If you choose “1 ms”, pay attention to electromagnetic noise and ambient light. • The response time of FX-11A is the time required for the output voltage to rise from 1 V (dark state voltage) to [90 % of {light state voltage – 1 V (dark state voltage)} + 1 V (dark state voltage)] or the time required for the output voltage to fall from the light state voltage to [10 % of {light state voltage – 1 V (dark state voltage)} + 1 V (dark state voltage)]. The response time of FX-11A is constant regardless of the amplitude of the output voltage. PRESSURE SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS WIRESAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES (e.g.) 4 V (Light state) 3.7 V LASER MARKERS 3V (Light state) 2.8 V 1.3V 1 V (Dark state) t1 t1 FIBER SENSORS t2 1.2 V 1V (Dark state) t2 t1 = t2: Response time DIMENSIONS (Unit: mm in) Refer to p.106~ for dimensions other than those given in the figures below. The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.com FX-11A Amplifier MS-DIN-2 Amplifier mounting bracket (Accessory for FX-11A) Assembly dimensions with attached amplifier mounting bracket Interference prevention selection switch Response time selection switch Incident beam indicator (Red) Sensitivity adjuster (8-turn) 3.2 0.126 Fiber lock lever 10 0.394 10 0.394 8 0.315 22 0.866 21.9 0.862 59 2.323 7.5 0.295 3 0.118 60 2.362 Beamreceiving part 2.4 0.094 0.4 0.016 ø1.8 ø0.071 ø4.2 ø0.165 cable, 2 m 6.562 ft long 31.5 1.240 3 Beam0.118 emitting part ø8.6 9 ø0.339 0.354 4.5 0.177 11.6 2-ø3.2 ø0.126 holes 0.457 Suitable for 35 mm 1.378 in width DIN rail 3.2 0.126 21.1 0.831 36.5 1.437 16 0.630 Note: The top view is shown without the cover. 2 0.079 Attached amplifier mounting bracket (MS-DIN-2) 2 0.079 5.2 0.205 3.2 0.126 35 1.378 2 0.079 Malerial: Cold rolled carbon steel (SPCC) (Uni-chrome plated) FX-300 FX-410 FX-11A t1 t 0.039 27 1.063 FX-100 FX-311 2 0.079 7.5 0.295 4.2 0.165 2-ø3.2 ø0.126 holes Fiber Fiber Sensor Sensor Amplifi ers Amplifiers 10 5 0.197 0.394 8.5 5.2 0.205 0.335 Fibers FT / FD / FR 21.6 0.850 16 0.630 Saturation indicator (Green) Selection Guide FX-301-F Other Products
FX-11A 价格&库存

很抱歉,暂时无法提供与“FX-11A”相匹配的价格&库存,您可以联系我们找货

免费人工找货
FX-11A
  •  国内价格 香港价格
  • 1+1857.487141+239.46593

库存:0