397
U-shaped Photoelectric Sensor
RT-610 SERIES
FIBER
SENSORS
Related Information
■■General terms and conditions.............. F-7
■■Glossary of terms........................ P.1455~
Amplifier Built-in
■■Sensor selection guide................... P.271~
■■General precautions.................... P.1458~
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
(RT-610-10/10R/50 only)
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
panasonic.net/id/pidsx/global
Suitable for address reading
and sensing cut-off marks
Beam axis alignment not required
2 types • 4 models are available.
Beam axis alignment is not required as the emitter and
the receiver are integrated in a single body.
There are three models having a sensing range of
10 mm 0.394 in, 20 mm 0.787 in, and 50 mm 1.969 in.
The models with sensing ranges of 10 mm 0.394 in
and 20 mm 0.787 in are also available in red LED type
and green LED type for mark sensing.
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
RT-610-10□
RT-610-50
10 mm 0.394 in
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
Robust die-cast enclosure
The robust die-cast enclosure maintains high reliability.
50 mm 1.969 in
U-shaped Photoelectric Sensor
RT-610 SERIES
APPLICATIONS
398
FIBER
SENSORS
Address reading
Sensing cut-off marks
Sensing overlapping paper
Traveling direction
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Code plate (flag)
Sensor installed on
the traveling object
LIGHT
CURTAINS /
SAFETY
COMPONENTS
Traveling direction
It can also be used to confirm the position of
transportation equipment such as crane, etc.
It can sense cut-off marks on a
transparent film.
Checking paper feed on
various printing machines.
For mark sensing
10 mm 0.394 in sensing range
SENSOR
OPTIONS
Appearance
Sensing range
Model No.
Output
RT-610-10
50 mm 1.969 in sensing range
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
ORDER GUIDE
Type
PRESSURE /
FLOW
SENSORS
10 mm
0.394 in
10 mm 0.349 in (fixed)
50 mm 1.969 in
50 mm 1.969 in (fixed)
5 m 16.404 ft cable length type
5 m 16.404 ft cable length type (standard: 1 m 3.281 ft) is also available.
When ordering this type, suffix “-C5” to the model No.
(e.g.) 5 m 16.404 ft cable length type of RT-610-10 is “RT-610-10-C5”.
Infrared LED
RT-610-10R
RT-610-10G
RT-610-50
Emitting element
NPN transistor
universal
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Red LED
STATIC
ELECTRICITY
PREVENTION
DEVICES
Green LED
LASER
MARKERS
PLC
Infrared LED
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
399
U-shaped Photoelectric Sensor
RT-610 SERIES
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
Item
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
Current consumption
40 mA or less
Output
Utilization category
Incorporated with two outputs, Light-ON / Dark-ON
Response time
0.1 ms or less
Operation indicator
Red LED (lights up under light received condition)
Sensitivity adjuster
–
Continuously variable adjuster
Pollution degree
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
Continuously variable adjuster
–
3 (Industrial environment)
IP62 (IEC)
Protection
Ambient temperature
IP62 (IEC)
IP66 (IEC)
–10 to +60 °C +14 to +140 °F (No dew condensation or icing allowed), Storage: –10 to +60 °C +14 to +140 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
Incandescent light: 3,500 ℓx at the light-receiving face
EMC
–
EN 60947-5-2
Vibration resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
Shock resistance
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting element
Infrared LED (modulated)
Red LED (modulated)
Green LED (modulated)
950 nm 0.037 mil
680 nm 0.027 mil
570 nm 0.022 mil
Peak emission wavelength
Enclosure earthing
Floating
Enclosure: Die-cast aluminum
Cable
0.3 mm2 4-core cabtyre cable, 1 m 3.281 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight
150 g approx.
180 g approx.
150 g approx.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) Make sure to confirm detection with an actual sensor before use.
I/O CIRCUIT AND WIRING DIAGRAMS
D1
(Brown) +V
4.7 kΩ
D2
Tr
Wiring diagram
Color code
Enclosure
Sensor circuit
Amplifierseparated
–
DC-12 or DC-13
Output operation
I/O circuit diagram
Power Supply
Built-in
ø4 mm ø0.157 in or more opaque or translucent object (Note 2)
NPN transistor universal
• Maximum sink current: 80 mA
• Residual voltage: 1 V or less (at 80 mA sink current)
Cable extension
Amplifier
Built-in
RT-610-10G
10 mm 0.394 in
12 to 24 V DC ±10 % Ripple P-P 10 % or less
FA
COMPONENTS
Selection
Guide
RT-610-10R
ø4 mm ø0.157 in or more opaque object
Material
UV
CURING
SYSTEMS
RT-610-50
50 mm 1.969 in
Supply voltage
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
MACHINE
VISION
SYSTEMS
RT-610-10
10 mm 0.394 in
Model No.
Sensing object
Environmental resistance
SENSOR
OPTIONS
For mark sensing
Sensing range (fixed)
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
U-shaped thru-beam
Type
Load
(Black or white) Output (Note)
ZD
Internal circuit
80 mA max.
(Blue) 0 V
Brown
+
–
12 to 24 V DC
±10 %
Users’ circuit
Note: The output does not incorporate a short-circuit protection circuit.
Do not connect it directly to a power supply or a capacitive load.
Symbols ... D1 : Reverse supply polarity protection diode
D2 : Reverse current prevention diode
ZD : Surge absorption zener diode
Tr : NPN output transistor
Black or white
Load
+
–
12 to 24 V DC
±10 %
Blue
Output operation
Color code
Output operation
Black
Light-ON
White
Dark-ON
U-shaped Photoelectric Sensor
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
DIMENSIONS (Unit: mm in)
RT-610-10□
10 mm 0.394 in sensing range type
RT-610 SERIES
400
Refer to p.1458~ for general precautions.
FIBER
SENSORS
LASER
SENSORS
Others
• The output does not incorporate a short-circuit protection
circuit. Do not connect it directly to a power supply or a
capacitive load.
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
The CAD data in the dimensions can be downloaded from our website.
RT-610-50
50 mm 1.969 in sensing range type
2SHUDWLRQ
LQGLFDWRU5HG
Beam axis
%HDPD[LV
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
¡¡FDEOH
PIWORQJ
%HDPD[LVSRVLWLRQPDUN
¡¡PRXQWLQJKROHV
0îWKUHDGVGHHS
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Power Supply
Built-in
Amplifierseparated
CX-400
CY-100
EX-10
EX-20
EX-30
EX-40
CX-440
EQ-30
EQ-500
MQ-W
RX-LS200
RX
RT-610
很抱歉,暂时无法提供与“RT-610-10G-C5”相匹配的价格&库存,您可以联系我们找货
免费人工找货