Emergency Stop Pushbutton Switches (22-dia. or 25-dia.)
A22NE-PD
A22NE-PD/A22NE-P/A22E
Install in 22-dia. or 25-dia.
Panel Cutout (When Using a Ring)
A22NE-P
• A wide variety of Emergency Stop Pushbuttons for all type of applications.
• Lock lever design provides quick and easy installation.
• Available vibration resistant terminals (A22NE-P & A22NE-PD).
• Use 25-dia. ring to install in 25-dia. panel cutouts. *
• Lock detection function provides an added level of safety by minimizing emergency stop button failures from
improper installation and damage.
* Switches with an IP69K degree of protection do not support the 25-dia.
Be sure to read the "Safety Precautions" on pages 17,
33, 50, and 56.
Premium - Lock detection and Vibration resistant
Page 2
A22NE-PD
A22E
Push-in Plus
Terminal Block Types
Common Accessories and Tools
Mid-grade - Vibration Resistant
A22NE-P
Common Note
1
Standard
A22E
Screw Terminal
Block Types
Page 16
Page 32
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) Push-in Plus Terminal Block Models
With Lock detection
A22NE-PD
A22NE-PD
Install in 22-dia. or 25-dia. Panel Cutout
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
Be sure to read the "Safety Precautions" on pages 12 and 56.
A22NE-P
(When Using a Ring)
• Push-in plus terminals greatly reduce wiring effort and provide
vibration resistant connections.
• A maximum of up to four contact points can be combined
together in the contact-point configuration.
• Oil-resistant to IP65 (non-lighted models) / IP65 (lighted
models) / IP69K high-temperature, high-pressure cleaning
(pull-reset models).
• Lock Detection function disconnects circuit when the switch
lock lever becomes unlocked from damage or improper
installation.
Model Number Structure
Model Number Legend (Completely Assembled) ........ Shipped as a set which includes the Operation Unit, LED
Lamp (lighted models only), and Switch Block.
1
2
4
5
6
-P D
-
7
-
A22E
A22NE-
3
1. Operation Unit size (diameter)
Code
Description
S
30 dia.
M
40 dia.
L
60 dia.
5. Contacts
Code
01
02
Number of
Contacts
one contact
two contacts
11
03
three contacts
NC
0
1
0
2
1
1
0
3
Code
Description
21
2
1
None
Turn-reset
12
1
2
P
Pull-reset *
22
2
2
13
1
3
04
0
4
* The pull-reset type is only available on the 40 dia.
Operation Unit, non-lighted type.
Not available on lighted types.
four contacts
Note. NO: 1a-contact NC: 1b-contact
3. Terminal specification
Code
Description
P
Push-in plus terminal block
4. Lock lever function
D
Code
Description
N
Non-lighted
C
24 VAC/VDC
* Lighting color is red.
Description
Lock-lever-linked contact function
7. Others (Degree of Protection)
Code
Description
None
IP65
69K
IP69K *
* IP69K is supported only by the Pull-reset models.
Common Note
Code
6. LED lamp voltage
Common Accessories and Tools
2. Reset function
Contacts
NO
2
A22NE-PD
A22NE-PD
Ordering Information
List of Models (Completely Assembled)
Non-lighted Models (Without EMO/EMS Indication)
Appearance
Degree of Protection Contact configuration *
Operation
40-dia. head
Medium Pull-reset
A22NE-MP-PD@@-N
IP65 oil-resistant
models
A22NE-P
40-dia. head
Medium Pull-reset
A22NE-MP-PD@@-N-69K
IP69K
30-dia. head
Small Turn-reset
A22NE-S-PD@@-N
IP65 oil-resistant
models
A22E
40-dia. head
Medium Turn-reset
A22NE-M-PD@@-N
IP65 oil-resistant
models
60-dia. head
Large Turn-reset
A22NE-L-PD@@-N
IP65 oil-resistant
models
Set Model
2NC
A22NE-MP-PD02-N
2NC, 1NO
A22NE-MP-PD12-N
3NC
A22NE-MP-PD03-N
2NC, 2NO
A22NE-MP-PD22-N
3NC, 1NO
A22NE-MP-PD13-N
4NC
A22NE-MP-PD04-N
2NC
A22NE-MP-PD02-N-69K
2NC, 1NO
A22NE-MP-PD12-N-69K
3NC
A22NE-MP-PD03-N-69K
2NC, 2NO
A22NE-MP-PD22-N-69K
3NC, 1NO
A22NE-MP-PD13-N-69K
4NC
A22NE-MP-PD04-N-69K
2NC
A22NE-S-PD02-N
2NC, 1NO
A22NE-S-PD12-N
3NC
A22NE-S-PD03-N
2NC, 2NO
A22NE-S-PD22-N
3NC, 1NO
A22NE-S-PD13-N
4NC
A22NE-S-PD04-N
2NC
A22NE-M-PD02-N
2NC, 1NO
A22NE-M-PD12-N
3NC
A22NE-M-PD03-N
2NC, 2NO
A22NE-M-PD22-N
3NC, 1NO
A22NE-M-PD13-N
4NC
A22NE-M-PD04-N
2NC
A22NE-L-PD02-N
2NC, 1NO
A22NE-L-PD12-N
3NC
A22NE-L-PD03-N
2NC, 2NO
A22NE-L-PD22-N
3NC, 1NO
A22NE-L-PD13-N
4NC
A22NE-L-PD04-N
Color of cap
Red
Common Accessories and Tools
* In addition to the above, we also provide the following contact configurations: [1NC], [1NC, 1NO], and [1NC, 2NO]. Ask your OMRON
representative for details.
Lighted Model (Without EMO/EMS Indication)
Appearance
Operation
40-dia. head
Medium Turn-reset
A22NE-M-PD@@-C
Common Note
3
Degree of
Protection
IP65
Contact
configuration
*
LED lamp voltage
Set Model
2NC
A22NE-M-PD02-C
2NC, 1NO
A22NE-M-PD12-C
3NC
2NC, 2NO
24 V AC/DC
Color of cap
A22NE-M-PD03-C
A22NE-M-PD22-C
3NC, 1NO
A22NE-M-PD13-C
4NC
A22NE-M-PD04-C
* In addition to the above, we also provide the following contact configurations: [1NC], [1NC, 1NO], and [1NC, 2NO]. Ask your OMRON
representative for details.
Red
A22NE-PD
Operation Unit
Non-lighted
Size
Function
Small (30 dia.)
Medium (40 dia.)
Degree of protection
Large (60-dia.)
Single item order model
A22NE-PD
Accessories (Order Separately)
A22NE-MP-N
IP65 oil-resistant models
---
---
A22NE-MP-N-69K
IP69K
---
---
A22NE-P
Pull-reset
A22NE-M-N
Turn-reset
A22NE-L-N
IP65 oil-resistant models
A22E
A22NE-MRO-N
A22NE-MRO-N-RD
A22NE-S-N
A22NE-MRS-N
A22NE-MRS-N-RD
Common Accessories and Tools
Lighted
Size
Function
Sealing capability
Medium (40 dia.)
Single item order model
A22NE-M-L
Turn-reset
IP65
Appearance
LED light
Red
Rated voltage
24 V AC/DC
Model
A22NZ-L-RC
Remarks
These are provided with the
completely assembled set of
lighted models. Order LED Lamps
only when replacing them.
Common Note
LED lamp
Note: For details on the accessories common to the screw terminal block models and push-in plus terminal block models, refer to "Common
Accessories and Tools (Order Separately)" on page 51.
4
A22NE-PD
A22NE-PD
Specifications
Certified Standard Ratings
Certified Standards
• UL508 (File No. E76675), CSA C22.2 No.14
5 A at 125 VAC, 3 A at 250 VAC B300
• TÜV (EN60947-5-1) - Certified direct opening (EN60947-5-5)
AC-15 3 A at 125 VAC
DC-13 1 A at 30 VDC
• CCC (GB14048.5)
AC-15 3 A at 125 VAC
DC-13 1 A at 30 VDC
Standards
File No.
UL *
UL508, C22.2 No.14
E76675
TÜV SÜD
EN60947-5-1
Consult your OMRON
(Certified direct opening),
representative for details.
EN60947-5-5
CQC (CCC)
GB14048.5
Consult your OMRON
representative for details.
Note: Only models with NC contacts have a direct opening
mechanism.
* UL-certification for CSA C22.2 No. 14 has been obtained.
Applicable Standards
A22NE-P
UL1059, UL486E
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not provided in the
main unit.
Ratings
Contacts (Standard Load)
Rated
Rated carry
insulation
current (A)
voltage (V)
A22E
250
5
Rated
voltage
(V)
LED Lamp (A22NZ-L-RC)
Rated current (A)
Rated voltage
AC15
AC12
DC13
DC12
(Inductive (Resistive (Inductive (Resistive
load)
load)
load)
load)
30 VAC
---
---
---
---
125 VAC
3A
5A
---
---
250 VAC
1.5 A
3A
---
---
30 VDC
---
---
1A
2A
125 VDC
---
---
0.22 A
0.4 A
250 VDC
---
---
0.1 A
0.2 A
Note: 1. The above ratings were obtained by conducting tests under
the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
Common Accessories and Tools
Common Note
5
Certification
body
2. Minimum applicable load: 1 mA at 5 VDC (Resistive load)
The operating range may vary depending on the usage
conditions and type of load.
24 VAC/VDC
Operating voltage
Current value
24 VAC/VDC ± 10%
Approx. 12 mA
A22NE-PD
A22NE-PD
Characteristics
Operation
Item
Allowable operating Mechanical
frequency
Electrical
Turn-reset
Pull-reset
Non-lighted model
Lighted Model
Non-lighted model
Non-lighted model
(Models with IP69K)
A22NE-@-PD@@-N-@
A22NE-M-PD@@-C-@
A22NE-MP-PD@@-N-@
A22NE-MP-PD@@-N-69K
30 operations/minute or less (One operation consists of set and reset operations.)
30 operations/minute or less (One operation consists of set and reset operations.)
Insulation resistance *1
100 MΩ min. (at 500 VDC)
Contact resistance
100 mΩ max. (initial value)
Dielectric
strength
A22NE-P
Between
2,000 VAC, 50/60 Hz 1 minute (initial value)
terminals of
same polarity*1
Between
2,000 VAC, 50/60 Hz 1 minute (initial value)
terminals of
different polarity
Between each
terminal and 2,000 VAC, 50/60 Hz 1 minute (initial value)
ground
Malfunction
10 to 55 Hz, 1.5 mm double amplitude (contact separation within 1 ms)
Shock
resistance
Malfunction
250 m/s2 max. (contact separation within 1 ms)
Mechanical
300,000 operations min. (One operation consists of set and reset operations.)
100,000 operations min.
(One operation consists of
set and reset operations.)
Electrical
(100 mA at 24
250,000 operations min. (One operation consists of set and reset operations.)
VAC (Resistive
load))
100,000 operations min.
(One operation consists of
set and reset operations.)
Durability
A22E
Vibration
resistance
Electrical
(3 mA at 250
100,000 operations min. (One operation consists of set and reset operations.)
VAC (Resistive
load))
Ambient operating temperature *2 -20 to +70°C
Ambient operating humidity
35 to 85% RH
Ambient storage temperature *2
-40 to +70°C
IP65 oil-resistant models
Electric shock protection class
Class II
PTI (tracking characteristic)
175
Degree of contamination
3 (EN 60947-5-1)
-20 to +70°C
-20 to +70°C *3
IP65
IP65 oil-resistant models
IP69K
Approx. 95 g
Approx. 125 g
Approx. 135 g
Common Accessories and Tools
Degree of protection *4
-20 to +55°C
Minimum direct opening stroke 11 mm
Minimum direct opening force
45 N
Conditional short-circuit current
100 A (EN 60947-5-1)
Wight (for a 40-dia. head
2NC/2NO Operation Unit)
Approx. 95 g
*1. State when an LED is not added between terminals of the same polarity on a lighting unit.
*2. With no icing or condensation.
*3. Capable of operation at up to 80°C under IP@9K testing conditions per JIS D 5020.
*4. The degree of protection from the front of the panel.
Turn-reset
Item
Lighted / non-lighted models
Common Note
Operating Characteristics
Pull-reset
Non-lighted model
Non-lighted model
(Models with IP69K)
Total travel force (TTF)
45 N max.
60 N max.
70 N max.
Return force (RF)
0.25N·m max. *
60 N max.
70 N max.
Total travel (TT)
10 ±1 mm
5.5 ±1 mm
* Rotation torque value.
6
A22NE-PD
A22NE-PD
Terminal Arrangement (BOTTOM VIEW)
Non-lighted
A22NE-P
One contact (1NC)
Two contacts (2NC)
Three contacts (3NC)
Two contacts (1NC + 1NO)
Three contacts
(2NC + 1NO)
Four contacts
(3NC + 1NO)
Four contacts (4NC)
Lighted
Terminal arrangement
A22E
The switch terminal is same as that in the non-lighted models.
Indicates the terminals for lighting (X1-X2).
(Example: Four contacts (4NC) Lighted models)
Lock lever
Terminal (insertion) hole
3.9 (0.3)
36.3
(0.3) 3.9
11
3.9
9
Common Accessories and Tools
31
35.9
Terminal Arrangement
Type
Terminal Arrangement (BOTTOM VIEW)
1NC, 1NO (two contacts)
2NC, 2NO (four contacts)
NO
14
NO
13
24
11
22
3NC, 1NO (four contacts)
NO
23
14
21
12
NC
13
32
11
22
4NC (four contacts)
NO
31
14
21
12
31
14
NC
13
32
11
22
13
32
NC
31
42
21
12
31
42
41
Non-lighted
NC
12
Common Note
7
NC
NO
NO
14
Lighted
X2
13
24
14
11
22
32
12
NO
X2
NC
21
22
12
Note: The terminal arrangement shows the representative. It depends on the number of contacts in the series.
22
41
X1
NC
11
11
NC
X2
NC
21
NC
NC
X1
NC
11
NC
NC
NC
13
X1
NC
NC
NC
NO
23
X2
X1
12
NC
NC
21
12
11
A22NE-PD
A22NE-PD
Structure and Nomenclature
Operation Unit
Color: Red
Non-lighted
LED lighting
Lamp
Light source
• LED Lamp
A22NE-P
Switch
}
Mounting Latches
Switch Blocks
Lighting unit
Contact Ratings
3 A at 250 VAC
5 A at 125 VAC
Lighting Method
Non-lighted
Lighted (LED)
A22E
Common Accessories and Tools
Common Note
8
A22NE-PD
A22NE-PD
Dimensions
(Unit: mm)
Non-lighted Models
A22NE-MP-PD@@-N
A22NE-MP-PD@@-N-69K
Pull-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
Pull-reset (40-dia.) Degree of Protection: IP69K
40 dia.
45
40 dia.
45
1.8
5.9
54.7
1.8
(0.5)
32
A22NE-P
5.9
55
32
A22NE-S-PD@@-N
A22NE-M-PD@@-N
Small Turn-reset (30-dia.) Degree of Protection:
IP65 oil-resistant models
Medium Turn-reset (40-dia.) Degree of Protection:
IP65 oil-resistant models
45
40 dia.
45
30 dia.
1.8
1.8
(0.5)
(0.5)
5.9
55
32
32
5.9
55
Note: The dimensions the same even if the Operation Unit is replaced
with the A22NE-MR@-N or the A22NE-MR@-N-RD.
A22NE-L-PD@@-N
A22E
Large Turn-reset (60-dia.) Degree of Protection:
IP65 oil-resistant models
60 dia.
45
(0.5)
1.8
5.9
55
32
Common Accessories and Tools
Lighted Model
A22NE-M-PD@@-C
Medium Turn-reset (40-dia.) Degree of Protection: IP65
45
40 dia.
(0.5)
1.8
5.9
32
55
Common Note
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Accessories (Order Separately)
LED Lamp
A22NZ-L-RC
24.3
9.8 dia.
9 dia.
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 51.
9
A22NE-PD
Mounting to the Panel
(1) Preparing the Panel
(3) Mounting the Operation Unit on the Panel
Panel hole dimension and panel thickness
• If outer surface treatment such as coating is performed for the panel, the panel
dimensions after outer surface treatment must meet the specified panel
dimensions.
Panel hole dimension
Panel thickness
22.3 dia.
1 to 5 mm
22.3
+0.4
0
• Do not tighten the Tightening Nut more than necessary using tools such as
pointed-nose pliers.
• Doing so will damage the Tightening Nut.
(The tightening torque of the Tightening Nut is 1.0 to 2.0 N·m.)
Tightening Wrench: A22Z-3905
Panel Hole of 22.3-mm Diameter
• Insert the Operation Unit from the front of the panel, insert the Lock Ring and
Tightening Nut from the back of the panel, and tighten the Tightening Nut.
Before tightening, check that the rubber washer is present between the
Operation Unit and the panel.
A22NE-PD
Application
dia.
Panel
When using a A22Z-3360 (Order Separately) Lock Ring
22.3 dia.
Tightening Wrench
(order separately, A22Z-3905)
3.2 +0.2
0
R0.8 max.
22.3 dia. +0.4
0
Rubber Washer
+0.4
0
24.1
Hold here
A22NE-P
Tightening Nut
Lock Ring
Rubber washer
Tightening Nut
For 25-dia.
• Use the A22Z-R25 (Order Separately) rubber ring.
* Switches with an IP69K degree of protection do not support the 25dia.
Lock Ring
25
+0.5
0
dia.
When the A22Z-3360 Lock Ring (Order Separately) is used
• Take note of the direction when mounting the Lock Ring.
Panel
Projecting part
A22E
Panel
(2) Minimum mounting pitch (Dimension A, Dimension B)
Minimum mounting pitch
Type of operation unit
Dimension B (mm)
min.
50 *1
50
70
70
30-dia., 40-dia. models
60-dia. model
*1. If the Switch Unit lock levers all face the same direction at the
minimum mounting pitch, be sure to note the order the Switch Units
are attached to the Operation Unit.
*2. When using each accessory (Order Separately), set the A and B
dimensions in view of the dimensions of the accessories.
*3. Make sure the mounting pitch does not hinder the operation.
Lock Ring
Panel Hole of 25-mm Diameter
• Insert the A22Z-R25 (Order
Separately) between the Operation
Unit and Panel, and tighten the
Tightening Nut.
Before tightening, check that the
rubber washer supplied with the
Operation Unit is present between
the Operation Unit and the 25-dia.
Ring.
Operation Unit
Panel Hole Dimensions for 22.3 Diameter
R0.8 max.
22.3
+0.4
0
Panel Hole of 30-mm Diameter
• Insert the A22Z-A30 (Order
Separately) between the Operation
Unit and Panel, and tighten the
Tightening Nut.
Before tightening, check that the
supplied rubber washer is present
between the Operation Unit and
the panel, and between the 30-dia.
Resin Attachment and the panel.
* Switches with an IP69K degree of
protection do not support the 30dia.
Operation Unit
3.2 +0.2
0
Common Accessories and Tools
Dimension A (mm)
min.
dia.
Rubber washer
(provided with the
Operation Unit)
24.1+0.4
0
Dimension A
Dimension B
22.3
+0.4
0
dia.
24.8 dia.
22.3
+0.4
0
30-dia.
Resin Attachment
A22Z-A30
Rubber Washer
(included)
Mounting Panel
25-dia. Ring
A22Z-R25
27 dia.
0.5
1.3
dia.
Lock Ring
Tightening Nut
Panel
Lock Ring
Using the
Lock Ring
Standard switch
Tightening Nut
Panel Cutouts
Panel thickness
25 mm dia.
1 to 5 mm
30 mm dia.
1 to 3 mm
Common Note
22 dia.
Rubber Washer
(provided with the
Operation Unit)
10
A22NE-PD
A22NE-PD
Removing the Switch Unit
Installing the LED Lamp (Lighted Models)
When the Switch Unit is to be Removed
When the LED Lamp is to be Installed
Slowly push the release port (concave part) of the lock lever with a
screwdriver to release the lock. The lock lever moves to the release position.
Insert the protrusions on the LED Lamp into the guides on the Switch Unit in
direction (1), and then turn the LED Lamp in direction (2) to lock it in place.
2
Lock lever concave part
A22NE-P
Release position
Locked position
When the lock lever is at the released position in this Switch, the NO and NC
contact operation is reversed.
Set the lock lever to the locked position when using the Switch.
A22E
Common Accessories and Tools
Common Note
11
1
A22NE-PD
Be sure to read the precautions for All PushButton Switches in the website at: http://www.ia.omron.com/.
Indication and Meaning for Safe Use
Warning
Indicates a potentially hazardous
situation that, if not avoided, could
result in serious injury or death.
Additionally there may be significant
property damage.
Comments on what to do or avoid doing, to
use the product safely.
Precautions for
Correct Use
Supplementary comments on what to do or
avoid doing to use the product safely and
prevent its malfunctioning or an adverse
effect on its performance or functions.
WARNING
Do not perform wiring with power supplied to the Switch/
Indicator. Do not touch the terminals or other charged
parts while power is being supplied. Doing so may result
in electric shock.
Precautions for Safe Use
• Make sure the Operation Unit and the Switch Unit are properly
assembled.
(1) Mark
Operation Unit
(2)
Lock Hole of Lock Lever
(1)
BD
Convex Part
Wire Type
(2)
Switch Unit
Wire
material
Recommended
Wire
Copper
Ferrules used: 10 to 12 mm
(Varies depending on the
0.25 to 1.5 mm2
recommended ferrule
AWG 24 to 16
conductor length)
Ferrules not used: 8 mm
Bottom A
Solid wire/
Stranded
Wire
Wire coating peeling
amount
Common Accessories and Tools
TOP indication
A22E
(1) Assembling the Operation Unit and Switch Unit
Align the TOP indication (the mark
) on the Operation Unit
with the TOP indication on the Switch Unit, and insert the
Operation Unit while keeping the bottom A pressed.
(2) Locking the lock lever
With a screwdriver inserted in the lock hole of the lock lever,
bring the screwdriver in contact with the convex part of the case,
and turn the lock lever until a clicking sound is heard.
A22NE-P
Precautions for
Safe Use
• Do not disassemble or modify the Switch/Indicator under any
circumstances.
• Doing so may prevent the Switch/Indicator from functioning to its
full capability. Do not drop the Switch/Indicator. Do not apply
pressure that may deform or alter the Switch/Indicator.
• The durability of the Switch varies considerably depending on the
switching conditions. Always test the Switch/Indicator under actual
working conditions before application and use the Switch/Indicator
only for the number of switching operations allowed.
• Do not allow the load voltage and current to exceed the rated
value. This may damage or burn out the Switch/Indicator.
• Do not use the Switch/Indicator in locations where explosive or
flammable gases or liquid may be present or scattered. The
electric ark or the heat caused by switching contacts may cause a
fire or explosion.
• Do not use the Switch/Indicator in locations where toxic gases,
such as H2S, SO2, NH3, HNO3, and Cl2, may be present, or in
locations subject to high temperature or humidity. Doing so may
damage the Switch/Indicator due to contact failure or corrosion.
• Do not use the Switch/Indicator submersed in oil or water, or in
locations continuously subject to splashes of oil or water. Doing so
may result in oil or water entering and damaging the Switch/
Indicator.
• Do not use or keep the Switch/Indicator under the following
conditions:
• Subject to severe temperature changes.
• Subject to high humidity or condensation.
• Subject to severe vibration or shock.
• Where direct rays of the sun strike.
• Where sea breeze may be present.
• Make sure that a rubber washer is present between the Operation
Unit and the panel. In models with IP69K, make sure the rubber
bush of the Operation Unit is properly attached.
Otherwise, the specifications of the protective structure may not be
satisfied.
• Do not apply excessive force to the Switch or wirings. Damage or
deformation of the Switch Unit could result in an improper contact
or a loss of safety.
• Use an appropriate wiring and crimp terminals (hereinafter, called
ferrule terminals).
• Exercise caution to avoid wiring errors when connecting the
terminals.
• To prevent wiring materials from smoking or ignition, confirm wire
ratings and use the wiring materials given in the following table.
A22NE-PD
Safety Precautions
Use wiring crimp terminals and ferrule terminals of the specified
size.
Locked position
• When transition wiring is performed, make sure the switching
current inside the Switch and the current based on the transition
wiring is below the rated current of the Switch.
If a current value higher than the rated current flows, it could result
in emission of heat, or damage and deformation of the Switch,
which could cause fire and locking of the contact, and thus a loss
of safety.
Common Note
Release position
When the lock lever is at the released position in
this Switch, the NO and NC contact operation is
reversed.
Set the lock lever to the locked position when using the Switch.
12
A22NE-PD
A22NE-PD
A22NE-P
A22E
• After storing the product for a long time exceeding 1 year, perform,
at a minimum, inspections of the operating characteristics, contact
resistance, insulation resistance, and dielectric strength as well as
evaluate the product under the working conditions.
• This product is intended for indoor use only. Using the product
outdoors will result in failure.
• Do not wire anything to the release holes.
• Do not tilt or twist a flat-blade screwdriver while it is inserted into a
release hole on the terminal block. The terminal block may be
damaged.
• Insert a flat-blade screwdriver into the release holes at an angle.
The terminal block may be damaged if you insert the screwdriver
straight in.
• Do not allow the flat-blade screwdriver to fall out while it is inserted
into a release hole.
• Do not bend a wire past its natural bending radius or pull on it with
excessive force.
Doing so may cause the wire disconnection.
• Do not insert more than one wire into each terminal insertion hole.
• When mounting on a device with high airtightness, test operation
in advance. There is a risk that the negative pressure will prevent
the Operation Unit of from returning.
• Although the contacts of an A22NE-PD can be used with both the
standard loads and microloads, once a contact has opened or
closed under a load, you cannot again connect a small-capacity
load. Doing so could roughen the contact surface, and result in
loss of contact reliability.
• In the case of loads where an inrush current occurs when the
contact is opened or closed, the durability may reduce due to
extreme wear on the contacts.
If necessary, insert a contact protection circuit.
• If a contact weld, the lock lever might not return to the release
position, and contact inversion might not occur. In such a case,
move the lock lever to the release position, and remove the Switch
Unit from the Operation Unit.
Precautions for Correct Use
Wiring
1. Connecting Wires to the Push-In Plus Terminal Block
Part Names of the Terminal Block
Release
hole
Terminal
(insertion) hole
Connecting Wires with Ferrules and Solid Wires
• Insert the solid wire or ferrule straight into the terminal block until
the end strikes the terminal block.
• If a wire is difficult to connect because it is too thin, use a flat-blade
screwdriver in the same way as when connecting stranded wires.
Ferrule terminal or
solid wire
Common Accessories and Tools
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal block.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole. The angle should be appropriately 10 to 15°. If the
flat-blade screwdriver is inserted correctly, you will feel the spring
in the release hole.
2. With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until the end strikes the
terminal block.
3. Remove the flat-blade screwdriver from the release hole.
(2)
Common Note
13
Approx.
10 to 15°
(1)
(3)
Flat-head screwdriver
A22NE-PD
2. Removing Wires from the Push-In Plus Terminal Block
3. Recommended Ferrules and Crimp Tools
Coating peeling amount
Recommend Wire Type
Stripping length
(Ferrules not used)
0.25 to 1.5 mm2/AWG 24 to AWG 16
8 mm
Recommended ferrules
Applicable
wire
(mm2)
0.25
0.34
24
22
(2)
Approx.
10 to 15°
(1)
0.5
20
0.75
18
(3)
Flat-head screwdriver
Recommended ferrules
Ferrule
Stripping
conductor length (mm)
length
(Ferrules not
(AWG)
(mm)
used)
1/1.25 18/17
1.25/1.5 17/16
Phoenix
Contact
product
8
10
AI 0, 25-8
10
12
AI 0, 25-10
8
10
AI 0, 34-8
Weidmuller
product
Wago
product
H0.25/12
216-301
--H0.34/12
---
--216-302
10
12
AI 0, 34-10
8
10
AI 0, 5-8
H0.5/14
216-201
---
10
12
AI 0, 5-10
H0.5/16
216-241
8
10
AI 0, 75-8
H0.75/14
216-202
10
12
AI 0, 75-10
H0.75/16
216-242
216-203
8
10
AI 1-8
H1.0/14
10
12
AI 1-10
H1.0/16
216-243
8
10
AI 1, 5-8
H1.5/14
216-204
10
12
AI 1, 5-10
H1.5/16
216-244
Recommended Crimp Tools
Variocri
mp4
Note: 1. Make sure that the outer diameter of the wire coating is
smaller than the inner diameter of the insulation sleeve of
the recommended ferrule.
2. Make sure that the ferrule processing dimensions conform
to the following figures.
A22E
CRIMPFOX6
CRIMPFOX6T-F PZ6 roto
CRIMPFOX10S
A22NE-P
Use the following procedure to remove wires from the terminal block.
The same method is used to remove stranded wires, solid wires, and ferrules.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole. The angle should be appropriately 10 to 15°.
2. With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
3. Remove the flat-blade screwdriver from the release hole.
A22NE-PD
Checking Connections
• After the insertion, pull gently on the wire to make sure that it will
not come off and it is securely fastened to the terminal block.
• If you use a ferrule with a conductor length of 10 mm, part of the
conductor may be visible after the ferrule is inserted into the
terminal block, but the product insulation distance will still be
satisfied.
8 to 10 mm
Max. 2.6 mm
Recommended Flat-Blade Screwdrivers
Use a flat-blade screwdriver to connect and remove wires.
Use one of the following flat-blade screwdrivers.
The following table shows manufacturers and models as of 2015/Dec.
Side view
Front view
2.5 mm dia.
0.4 mm
Common Accessories and Tools
Max. 1.9 mm
2.5 mm
Manufacture
Wera
SZS 0,4 × 2,5
SZF 0-0,4 × 2,5 *
Phoenix Contact
0.4 × 2.5 × 75 302
Wiha
AEF.2,5 × 75
Facom
210-719
Wago
SDI 0,4 × 2,5 × 75
Weidmuller
* The SZF 0-0,4 × 2,5 (manufactured by Phoenix Contact) can be
procured through an OMRON exclusive purchase form (XW4Z-00B).
Common Note
Model
ESD 0,40 × 2,5
• After wiring the Switch/Indicator, provide a sufficient insulation
distance.
14
A22NE-PD
A22NE-PD
LED Lamps
• A current-limiting resistor is built in the LED lamp, so the
installation of an external resistance is not required.
• Lighting malfunction of the LED lamp
A micro-current of approximately 0.1 mA or less is sufficient to turn
on the LED lamps. Take a countermeasure like adding a resistor
to prevent mis-lighting in parallel to the LED lamp.
The micro-current varies with the machine (leak current or stray
capacity between cables, etc.). Select resistance value and
allowable power consumption that meet the actual current.
(Example of lighting malfunction prevention circuit)
When using a 24 VAC/DC Lighted Model
A22NE-P
X1
LED
lamp
R:10 kΩ (1 W)
Bleeder resistor
X2
Be sure to read the "Safety Precautions" on page 56.
A22E
Common Accessories and Tools
Common Note
15
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) Push-in Plus Terminal Block Models
A22NE-PD
A22NE-P
Install in 22-dia. or 25-dia. Panel Cutout
For the most recent information on models that have been
certified for safety standards, refer to your Omron website.
Be sure to read the "Safety Precautions" on pages 30 and 56.
Model Number Structure
A22NE-P
(When Using a Ring)
• Push-in plus terminals greatly reduce wiring effort and provide
vibration resistant connections.
• A lock lever provides a secure mounting of the switch assembly.
• A maximum of up to six contact points can be combined together
in the contact-point configuration.
• Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models) /
Supports IP69K high-temperature, high-pressure cleaning (pullreset models).
Model Number Legend (Completely Assembled) ........ Shipped as a set which includes the Operation Unit, LED
Lamp (lighted model only), Mounting Latches, Lighting
Units (lighted model only), and Switch Block.
1
3
2
A22NE-
5
-
6
-
-
(Example: A22NE-M-P102-N)
A22E
1. Operation Unit size (diameter)
4
4. Contacts
Code
Description
S
30 dia.
Number of
Code Switch Blocks
M
40 dia.
NO
NC
1
2
3
1
L
60 dia.
002
0
1
---
---
NC
---
Lighting unit
NC
102
1
1
NO
---
NC NO
Lighting unit
NC
202
0
2
NC
---
NC NC
Lighting unit
NC
2. Reset function
Unit position
Non-lighted
Description
212
1
2
NC NO NC
None
Turn-reset
222
0
3
NC NC NC
P
Pull-reset *
* The pull-reset type is only available on the 40 dia.
Operation Unit, non-lighted type.
Not available on lighted types.
2
---
Note 1. NO: 1a-contact
NC: 1b-contact
2. For details on the unit position, refer to the figure below.
3. Contact specification/Terminal specification
Code
P
3
Description
Standard load/Push-in plus terminal block
Common Accessories and Tools
Code
Lighted
5. LED lamp voltage
Description
N
Non-lighted
LED Lamp Voltage
---
A
6 VAC/DC
B
12 VAC/DC
C
Lighted
(LED) *
24 VAC/DC
D
100/110/120 VAC
E
200/220/230/240 VAC
* Lighting color is red.
6. Others (Degree of Protection/Control box)
Code
None
69K
Configuration
IP65
Common Note
Code
IP69K
B*
Built-in control box
* One-contact unit type.
16
A22NE-P
A22NE-PD
Ordering Information
List of Models (Completely Assembled)
Non-lighted Models
Appearance
Degree of Protection Contact configuration *
Operation
40-dia. head
Medium Pull-reset
A22NE-MP-P@@2-N
IP65 oil-resistant
models
A22NE-P
40-dia. head
Medium Pull-reset
A22NE-MP-P@@2-N-69K
IP69K
30-dia. head
Small Turn-reset
A22NE-S-P@@2-N
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-N
IP65 oil-resistant
models
A22E
60-dia. head
Large Turn-reset
A22NE-L-P@@2-N
Set Model
1NC (1)
A22NE-MP-P002-N
1NC, 1NO (2)
A22NE-MP-P102-N
2NC (2)
A22NE-MP-P202-N
2NC, 1NO (3)
A22NE-MP-P212-N
3NC (3)
A22NE-MP-P222-N
1NC (1)
A22NE-MP-P002-N-69K
1NC, 1NO (2)
A22NE-MP-P102-N-69K
2NC (2)
A22NE-MP-P202-N-69K
2NC, 1NO (3)
A22NE-MP-P212-N-69K
3NC (3)
A22NE-MP-P222-N-69K
1NC (1)
A22NE-S-P002-N
1NC, 1NO (2)
A22NE-S-P102-N
2NC (2)
A22NE-S-P202-N
2NC, 1NO (3)
A22NE-S-P212-N
3NC (3)
A22NE-S-P222-N
1NC (1)
A22NE-M-P002-N
1NC, 1NO (2)
A22NE-M-P102-N
2NC (2)
A22NE-M-P202-N
2NC, 1NO (3)
A22NE-M-P212-N
3NC (3)
A22NE-M-P222-N
1NC (1)
A22NE-L-P002-N
1NC, 1NO (2)
A22NE-L-P102-N
2NC (2)
A22NE-L-P202-N
2NC, 1NO (3)
A22NE-L-P212-N
3NC (3)
A22NE-L-P222-N
Color of cap
Red
* The number in parentheses ( ) indicates the number of switch units.
Lighted Model
Appearance
Degree of
Protection
Operation
Contact
configuration *
LED lamp voltage
1NC, 1NO (2)
Common Accessories and Tools
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-B
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-C
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-D
1NC (1)
A22NE-M-P002-B
12 VAC/VDC
A22NE-M-P202-B
1NC (1)
A22NE-M-P002-C
1NC, 1NO (2)
24 VAC/VDC
A22NE-M-P102-C
2NC (2)
A22NE-M-P202-C
1NC (1)
A22NE-M-P002-D
100, 110, 120 VAC
A22NE-M-P102-D
Common Note
2NC (2)
A22NE-M-P202-D
1NC (1)
A22NE-M-P002-E
1NC, 1NO (2)
220, 230, 240 VAC
Switch with Integrated Control Box
Contact configuration (Number of switch blocks)
A22NE-M-P102-E
A22NE-M-P202-E
* The number in parentheses ( ) indicates the number of switch units.
17
A22NE-M-P102-B
2NC (2)
2NC (2)
Appearance
A22NE-M-P102-A
A22NE-M-P202-A
1NC, 1NO (2)
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-E
6 VAC/VDC
2NC (2)
1NC, 1NO (2)
IP65
Color of cap
A22NE-M-P002-A
1NC (1)
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-A
Set Model
Model
1NC (1)
A22NE-M-P002-N-B
1NC, 1NO (2)
A22NE-M-P102-N-B
2NC (2)
A22NE-M-P202-N-B
Red
A22NE-P
them in combination for models that are not available as assembled Units. These can also be used as inventory for
maintenance parts.
Non-lighted
Lighted
Operation Unit
A22NE-PD
Subassembled ........ The Operation Unit, LED Lamp, Mounting Latches, Switch Blocks, and Lighting Unit can be ordered separately. Use
Operation Unit
A22NE-P
Mounting Latches
Push-in Plus Terminal Block
Push-in Plus Terminal Block
Common Note
* Up to three Switch Blocks can be mounted for multiple contacts.
Switch Blocks + Lighting Unit
Common Accessories and Tools
Switch Blocks *
A22E
LED Lamp
18
A22NE-P
A22NE-PD
Operation Unit
Non-lighted
Size
Function
Small (30 dia.)
Medium (40 dia.)
Sealing capability
Large (60-dia.)
Single item order model
A22NE-MP-N
IP65 oil-resistant models
---
---
Pull-reset
A22NE-P
A22NE-MP-N-69K
IP69K
---
---
A22NE-M-N
A22NE-MRO-N
A22NE-MRO-N-RD
A22E
A22NE-S-N
Turn-reset
A22NE-L-N
IP65 oil-resistant models
A22NE-MRS-N
A22NE-MRS-N-RD
Common Accessories and Tools
Lighted
Size
Function
Sealing capability
Medium (40 dia.)
Single item order model
A22NE-M-L
Turn-reset
IP65
Common Note
LED lamp
19
Appearance
LED light
Red
Rated voltage
Model
6 VAC/VDC
A22NZ-L-RA
12 VAC/VDC
A22NZ-L-RB
24 VAC/VDC
A22NZ-L-RC
100, 110, 120 VAC
A22NZ-L-RD
200, 220, 230, 240 VAC
A22NZ-L-RE
Remarks
These LED lamps are for
exclusive use with the A22N
and the A22NE-P. These are
provided with the completely
assembled set of lighted
models. Order LED lamps only
when replacing them.
A22NE-P
A22NE-PD
Accessories (Order Separately)
Item
Appearance
Contact specifications
1NO (Blue)
Standard load
A22NZ-S-P1AN
1NC (Red)
Standard load
A22NZ-S-P1BN
2NC (Red)
Standard load
A22NZ-S-P2BN
Switch Blocks
(one contact)
Switch Blocks
(two contacts)
Mounting
Latches
Provided as standard.
Order Switch Blocks only when
adding or replacing them.
Order Switch Blocks only when
adding or replacing them.
Standard load
A22NZ-S-P2CN
6 VAC/VDC
A22NZ-T-APN
12 VAC/VDC
A22NZ-T-BPN
24 VAC/VDC
A22NZ-T-CPN
100, 110, 120 VAC
A22NZ-T-DPN
200, 220, 230, 240 VAC
A22NZ-T-EPN
---
One hole, yellow box
These are provided with the
completely assembled set of
lighted models. Order Lighting
Units only when replacing them.
A22NZ-H-02
This Mounting Latch is for
exclusive use with the A22NE-P.
It is provided with the completely
assembled set.
Order Mounting Latches only
when mounting Switch Blocks or
Lighting Units that are
purchased individually.
A22NZ-A-B01Y
Material: Polycarbonate resin.
Can be combined with 1-contact
Switch Blocks.
(Cannot be combined with
2-contact Switch Blocks.) *
A22E
Control Boxes
(Enclosures)
1NO/1NC
(White)
Remarks
A22NE-P
Lighting unit
Model
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 51.
* The A22NZ-A-B01Y Control Box cannot be used in combination with the A22Z-3476-1 90-dia. Legend Plates for Emergency Stop or the A22ZEG@ E-stop Shrouds.
Common Accessories and Tools
Common Note
20
A22NE-P
A22NE-PD
Specifications
Certified Standard Ratings
Certified Standards
• UL508 (File No. E76675), CSA C22.2 No.14
6 A at 240 VAC, 10 A at 120 VAC
• TÜV (EN60947-5-1) - Certified direct opening (EN60947-5-5)
AC-15 3 A at 240 VAC
DC-13 4 A at 24 VDC
• CCC (GB14048.5)
AC-15 3 A at 240 VAC
DC-13 4 A at 24 VDC
Certification
body
Standards
File No.
UL *
UL508, C22.2 No.14
E76675
TÜV SÜD
EN60947-5-1
Consult your OMRON
(Certified direct opening),
representative for details.
EN60947-5-5
CQC (CCC)
GB14048.5
2017010305959182
Note: Only models with NC contacts have a direct opening
mechanism.
* UL-certification for CSA C22.2 No. 14 has been obtained.
Applicable Standards
A22NE-P
UL1059, UL486E (Push-in Plus Terminal Block Types)
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not provided in the
main unit.
Ratings
Contacts (Standard Load)
Rated
Rated carry
insulation
current (A)
voltage (V)
A22E
600
10
Rated
voltage
(V)
LED Lamp
Rated voltage
Rated current (A)
6 VAC/VDC
AC15
AC12
DC13
DC12
(Inductive (Resistive (Inductive (Resistive
load)
load)
load)
load)
Current value
6 VAC/VDC ± 10%
Approx. 11 mA
12 VAC/VDC
12 VAC/VDC ± 10%
Approx. 12 mA
24 VAC/VDC
24 VAC/VDC ± 10%
Approx. 12 mA
24 VAC
10
10
100 VAC
100 VAC ± 10%
120 VAC
6
10
110 VAC
110 VAC ± 10%
120 VAC
100 VAC to 130 VAC
200 VAC
200 VAC ± 10%
240 VAC
3
6
380 VAC
1.9
2
440 VAC
1.6
2
24 VDC
120 VDC
240 VDC
---
---
---
---
220 VAC
220 VAC ± 10%
4
8
230 VAC
230 VAC ± 10%
1.1
2.2
240 VAC
220 VAC to 250 VAC
0.55
1.1
Common Accessories and Tools
Note: 1. The above ratings were obtained by conducting tests under
the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
Common Note
21
Operating voltage
2. Minimum applicable load: 10 mA at 5 VDC (Resistive load)
The operating range may vary depending on the usage
conditions and type of load.
Approx. 12 mA
Approx. 12 mA
A22NE-P
A22NE-PD
Characteristics
Operation
Turn-reset
Item
Allowable operating Mechanical
frequency
Electrical
Pull-reset
Non-lighted model
Lighted Model
A22NE-@-P@@@-N
A22NE-M-P@@@-@
Non-lighted model
A22NE-MP-P@@@-N
A22NE-MP-P@@@-N-69K
30 operations/minute or less (One operation consists of set and reset operations.)
30 operations/minute or less (One operation consists of set and reset operations.)
Insulation resistance *1
100 MΩ min. (at 500 VDC)
Contact resistance
100 mΩ max. (initial value)
Between terminals
2,500 VAC, 50/60 Hz 1 minute (initial value)
of same polarity*1
2,500 VAC, 50/60 Hz 1 minute (initial value)
Vibration
resistance
Malfunction
10 to 55 Hz, 1.5 mm double amplitude (contact separation within 1 ms)
Shock
resistance
Malfunction
250 m/s2 max. (contact separation within 1 ms)
Mechanical
300,000 operations min. (One operation consists of set and reset
operations.)
100,000 operations min.
(One operation consists of
set and reset operations.)
Electrical
300,000 operations min. (One operation consists of set and reset
operations.)
100,000 operations min.
(One operation consists of
set and reset operations.)
Ambient operating temperature *2
-20 to +70°C
-20 to +70°C
-20 to +70°C *3
Ambient operating humidity
35 to 85% RH
Ambient storage temperature *2
-40 to +70°C
Degree of protection *4
IP65 oil-resistant models *5 IP65
IP65 oil-resistant models *5
IP69K
Electric shock protection class
Class II
PTI (tracking characteristic)
175
Degree of contamination
3 (EN 60947-5-1)
Minimum direct opening stroke
11 mm
Minimum direct opening force
45 N
Conditional short-circuit current
100 A (EN 60947-5-1)
Wight (for a 40-dia. head
1NC/1NO Operation Unit)
Approx. 55g
Approx. 85 g
Approx. 115 g
Durability
-20 to +55°C
Approx. 60g
A22E
Between each
terminal and
ground
A22NE-P
Dielectric
strength
Operating Characteristics
Turn-reset
Item
Pull-reset
Lighted / non-lighted models
Non-lighted model
Non-lighted model (Models with IP69K)
Total travel force (TTF)
45 N max.
60 N max.
70 N max.
Return force (RF)
0.25N·m * max.
60 N max.
70 N max.
Total travel (TT)
10 ±1 mm
5.5 ±1 mm
5.5 ±1 mm
Common Accessories and Tools
*1. State when an LED is not added between terminals of the same polarity on a lighting unit. Does not apply to lighted-type 100 to 200 V lighting units.
*2. With no icing or condensation.
*3. Capable of operation at up to 80°C under IP@9K testing conditions per JIS D 5020.
*4. The degree of protection from the front of the panel.
*5. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
* Rotation torque value.
Non-lighted (two contacts)
Non-lighted (three contacts)
(20°)
(17.6°)
(20°)
Terminal
(insertion) hole
Terminal
(insertion) hole
31.9
Switch Blocks
4
20
Lock lever
Terminal
(insertion) hole
31.9
Switch Blocks
(17.6°)
Lock lever
(17.6°)
Lock lever
10
Lighted (two contacts)
(20°)
31.9
Common Note
Terminal Arrangement (BOTTOM VIEW)
Switch Blocks
4
10
20
4
10
20
Lighting unit
22
A22NE-P
A22NE-PD
Terminal connection
Type
Terminal Connection (BOTTOM VIEW)
1NC, 1NO (two contacts)
2NC (two contacts)
2NC, 1NO (three contacts)
3NC (three contacts)
NC
NO
NC
NC
NC
NC
NO
NC
NC
NC
1
3
1
1
1
1
3
1
1
1
2
4
2
2
2
2
4
2
2
2
Non-lighted
A22NE-P
X1
1
Lighted
X1
1
3
X
X
4
X2
2
1
X2
2
2
Note: The above terminal connection diagrams are examples for 1NO, 1NC (two contacts), or 2NC (two contacts).
Terminal wiring drawings of two-contact Switch Units
Type
A22E
A
Terminal Connection (BOTTOM VIEW)
2NC (two contacts)
1NC, 1NO (two contacts)
21
21
22
22
11
13
12
14
A
B
B
Common Accessories and Tools
Structure and Nomenclature
Operation Unit
Color: Red
Non-lighted
LED lighting
Lamp
Light source
• LED Lamp
Common Note
Switch
}
Mounting Latches
Switch Blocks
Lighting unit
Contact Ratings
6 A at 240 VAC
10 A at 120 VAC
Lighting Method
Non-lighted
Lighted (LED)
23
A22NE-P
(Unit: mm)
Non-lighted Models
A22NE-MP-P@@2-N
A22NE-MP-P@@2-N-69K
Pull-reset (40-dia.) Degree of Protection: IP65 oil-resistant models
Pull-reset (40-dia.) Degree of Protection: IP69K
40 dia.
42.5
40 dia.
42.5
5.9
1.8
(0.5)
1.8
5.9
39
32
A22NE-P
32
39.5
A22NE-S-P@@2-N
A22NE-M-P@@2-N
Small Turn-reset (30-dia.) Degree of Protection:
IP65 oil-resistant models
Medium Turn-reset (40-dia.) Degree of Protection:
IP65 oil-resistant models
30 dia.
40 dia.
42.5
42.5
1.8
1.8
(0.5)
(0.5)
5.9
5.9
32
A22NE-PD
Dimensions
32
39.5
39.5
A22NE-L-P@@2-N
Large Turn-reset (60-dia.) Degree of Protection:
IP65 oil-resistant models
60 dia.
A22E
Note: The dimensions the same even if the Operation Unit is
replaced with the A22NE-MR@-N or the A22NE-MR@-N-RD.
42.5
5.9
39.5
32
Lighted Model
A22NE-M-P@@2-@
Dimensions when a two-contact Switch Block is attached
Medium Turn-reset (40-dia.) Degree of Protection: IP65
40 dia.
40 dia.
Common Accessories and Tools
1.8
(0.5)
44
42.5
5.9
32
39.5
Note: Unless otherwise specified, a tolerance of ±0.8 mm applies to all dimensions.
32
5.9
1.8
55
Common Note
(0.5)
1.8
(0.5)
24
A22NE-P
A22NE-PD
Accessories (Order Separately)
Switch Block with Push-In Plus technology
Switch Block (one contact)
Switch Block (two contacts)
A22NZ-S-P1@N
A22NZ-S-P2@N
4
4
5
5
23.8
16.4
39.3
31.9
9.9
47.6
A22NE-P
9.9
47.6
Lighting unit
Mounting Latches
A22NZ-T-@PN
A22NZ-H-02
R29.5
12 dia.
30
26.4
23.8
16.4
9.9
47.6
17.1
A22E
51.3
LED Lamp
A22NZ-L-@@
24.3
9.8 dia.
9 dia.
Common Accessories and Tools
Control Box
A22NZ-A-B01Y
Four, M4 Phillips
binding screws
22.3 dia.
24.2
40
Case (Black)
Cover (Yellow)
Four, 3.7-dia.
(M4-tapped holes)
10
Two, 14-dia.
(Bottom lead hole)
Two, 21.4 dia.
(Side lead hole)
Two, 4.4-dia.
(oval mounting hole)
62
80
24.2
3.2
Common Note
18.5
3.2
80
5.4
10
38
40
59.9
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 51.
25
A22NE-P
Mounting to the Panel
(1) Preparing the Panel
(3) Mounting the Operation Unit on the Panel
Panel hole dimension and panel thickness
• If outer surface treatment such as coating is performed for the panel, the panel
dimensions after outer surface treatment must meet the specified panel
dimensions.
Panel hole dimension
Panel thickness
22.3 dia.
1 to 5 mm
22.3
+0.4
0
• Do not tighten the Tightening Nut more than necessary using tools such as
pointed-nose pliers.
• Doing so will damage the Tightening Nut.
(The tightening torque of the Tightening Nut is 1.0 to 2.0 N·m.)
Tightening Wrench: A22Z-3905
Panel Hole of 22.3-mm Diameter
• Insert the Operation Unit from the front of the panel, insert the Lock Ring and
Tightening Nut from the back of the panel, and tighten the Tightening Nut.
Before tightening, check that the rubber washer is present between the
Operation Unit and the panel.
A22NE-PD
Application
dia.
Panel
When using a A22Z-3360 (Order Separately) Lock Ring
22.3 dia.
Tightening Wrench
(order separately, A22Z-3905)
3.2 +0.2
0
R0.8 max.
Rubber Washer
A22NE-P
Tightening Nut
Lock Ring
22.3 dia. +0.4
0
Hold here
24.1+0.4
0
Rubber washer
Tightening Nut
For 25-dia.
• Use the A22Z-R25 (Order Separately) rubber ring.
* Switches with an IP69K degree of protection do not support the 25dia.
+0.5
0
When the A22Z-3360 Lock Ring (Order Separately) is used
• Take note of the direction when mounting the Lock Ring.
dia.
Panel
Projecting part
A22E
25
Lock Ring
Panel
(2) Minimum mounting pitch (Dimension A, Dimension B)
Lock Ring
Minimum mounting pitch
Type of operation unit
Dimension B (mm)
min.
50 *1
50
70
70
30-dia., 40-dia. models
60-dia. model
*1. If the Mounting Collar lock levers all face the same direction at the
minimum mounting pitch, be sure to note the order the mounting
collars are attached to the Operation Unit.
*2. When using each accessory (Order Separately), set the A and B
dimensions in view of the dimensions of the accessories.
*3. Make sure the mounting pitch does not hinder the operation.
Panel Hole of 25-mm Diameter
• Insert the A22Z-R25 (Order
Separately) between the
Operation Unit and Panel, and
tighten the Tightening Nut.
Before tightening, check that the
rubber washer supplied with the
Operation Unit is present between
the Operation Unit and the 25-dia.
Ring.
Operation Unit
Panel Hole of 30-mm Diameter
• Insert the A22Z-A30 (Order
Separately) between the Operation
Unit and Panel, and tighten the
Tightening Nut.
Before tightening, check that the
supplied rubber washer is present
between the Operation Unit and
the panel, and between the 30-dia.
Resin Attachment and the panel.
* Switches with an IP69K degree of
protection do not support the 30-dia.
Operation Unit
Panel Hole Dimensions for 22.3 Diameter
R0.8 max.
22.3
+0.4
0
3.2 +0.2
0
Rubber washer
(provided with the
Operation Unit)
dia.
22 dia.
24.8 dia.
0.5
27 dia.
30-dia.
Resin Attachment
A22Z-A30
Rubber Washer
(included)
Mounting Panel
1.3
Dimension B
22.3
+0.4
0
dia.
22.3
+0.4
0
Lock Ring
dia.
Tightening Nut
Panel
Lock Ring
Tightening Nut
Using the
Lock Ring
Standard switch
Panel Cutouts
Panel thickness
25 mm dia.
1 to 5 mm
30 mm dia.
1 to 3 mm
Common Note
Rubber Washer
(provided with the
Operation Unit)
25-dia. Ring
A22Z-R25
24.1+0.4
0
Dimension A
Common Accessories and Tools
Dimension A (mm)
min.
26
A22NE-P
A22NE-PD
Removing the Mounting Latch
Attaching the LED Lamp to the Lighting Unit
When the Mounting Latch is to be Removed
When the LED Lamp is to be Installed
• Press the lock lever in from the back side to release the lock, and then hook
the Mounting Collar with a screwdriver, move it in the direction indicated at
(2), and remove it. Turn the lever all of the way until it clicks into place.
• Insert the protrusions on the LED Lamp into the guides on the Lighting Unit
and then turn the LED Lamp in direction (2) to lock it in place.
(1)
2
1
A22NE-P
(2)
(3)
Control Box
(1) Mounting the Switch
Mount the Switch in the same way as for a standard panel.
The tightening torque of the Box screws is 1.4 to 2.0 N·m.
Switch Blocks and Lighting Unit
(1) Installing the Switch Blocks and Lighting Unit
Legend Plate
• Catch the projection on the opposite side of the Mounting Collar from the
lever side and press the Switch Block in the direction indicated at (1).
A22E
(1)
(2) Creating a Cable Hole
(2) Removing the Switch Blocks and Lighting Units
• Insert a screwdriver into the gap between the Mounting Collar and Switch
Block and press it inward in the direction shown at (2).
Common Accessories and Tools
Common Note
27
To open a cable hole, leave the cover attached, place the tip of a
screwdriver in the grooves at four locations around the cable hole, and strike
the screwdriver with a hammer to open the hole.
Screwdriver
(1)
Side
Cover
Switch Box
Cable
Hole
Groove
(2)
Strike at four
diagonally
opposed locations
to open the hole.
(3) Securing the Connector Cable
(3)
1. Insert the connector into the cable port hole in the Box and
secure with the fixing ring inside the box.
2. Pass the tightening cap through the cable, insert the cable into
the connector, and tighten the tightening cap to secure the cable.
O Ring
Fixing
Ring
Connector
Tightening cap
Cable
Box
Cable diameter (mm)
Connector
7 to 9 dia.
A22Z-3500-1
9 to 11 dia.
A22Z-3500-2
A22NE-P
Be sure to read the precautions for All PushButton Switches in the website at: http://www.ia.omron.com/.
Indication and Meaning for Safe Use
Warning
Indicates a potentially hazardous
situation that, if not avoided, could
result in serious injury or death.
Additionally there may be significant
property damage.
Comments on what to do or avoid doing, to
use the product safely.
Precautions for
Correct Use
Supplementary comments on what to do or
avoid doing to use the product safely and
prevent its malfunctioning or an adverse
effect on its performance or functions.
WARNING
Do not perform wiring with power supplied to the Switch/
Indicator. Do not touch the terminals or other charged
parts while power is being supplied. Doing so may result
in electric shock.
Precautions for Safe Use
• If the Operation Unit is separated from the Switch Units, the
equipment will not stop, resulting in a hazardous situation.
Make sure the Operation Unit, Mounting Latches, and the Switch
Units are properly assembled.
Operation Unit
1
Wire Type
Lock lever
Make sure the hooking part (convex part) on the Mounting Latches
is perfectly latched into the hooking part (concave part) on the
Switch Block.
Mounting
Latches
Solid wire/
Stranded
Wire
•
Switch Blocks
• When transition wiring is performed, make sure the switching
current inside the Switch and the current based on the transition
wiring is below the rated current of the Switch.
If a current value higher than the rated current flows, it could result
in emission of heat, or damage and deformation of the Switch,
which could cause fire and locking of the contact, and thus a loss
of safety.
• Do not disassemble or modify the Switch/Indicator under any
circumstances.
•
•
•
•
•
Recommended
Wire
Wire coating peeling
amount
Copper
Ferrules used: 10 to 12 mm
(Varies depending on the
0.25 to 1.5 mm2
recommended ferrule
AWG 24 to 16
conductor length)
Ferrules not used: 8 mm
Use wiring crimp terminals and ferrule terminals of the specified
size.
After storing the product for a long time exceeding 1 year, perform,
at a minimum, inspections of the operating characteristics, contact
resistance, insulation resistance, and dielectric strength as well as
evaluate the product under the working conditions.
This Switch/Indicator is intended for indoor use only.
Using the Switch/Indicator outdoors may result in failure.
Do not wire anything to the release holes.
Do not tilt or twist a flat-blade screwdriver while it is inserted into a
release hole on the terminal block. The terminal block may be
damaged.
Insert a flat-blade screwdriver into the release holes at an angle.
The terminal block may be damaged if you insert the screwdriver
straight in.
Do not allow the flat-blade screwdriver to fall out while it is inserted
into a release hole.
Do not bend a wire past its natural bending radius or pull on it with
excessive force.
Doing so may cause the wire disconnection.
Common Note
•
Wire
material
Common Accessories and Tools
Mounting
Latches
2
A22E
Align the TOP indication (the
mark) on the Operation Unit with
the TOP indication on the Mounting Latches to fit it properly, and
turn the lock lever on the Mounting Latch in the direction shown in
the figure below until a clicking sound is heard.
A22NE-P
Precautions for
Safe Use
• Doing so may prevent the Switch/Indicator from functioning to its
full capability. Do not drop the Switch/Indicator. Do not apply
pressure that may deform or alter the Switch/Indicator.
• The durability of the Switch varies considerably depending on the
switching conditions. Always test the Switch/Indicator under actual
working conditions before application and use the Switch/Indicator
only for the number of switching operations allowed.
• Do not allow the load voltage and current to exceed the rated
value. This may damage or burn out the Switch/Indicator.
• Do not use the Switch/Indicator in locations where explosive or
flammable gases or liquid may be present or scattered. The
electric ark or the heat caused by switching contacts may cause a
fire or explosion.
• Do not use the Switch/Indicator in locations where toxic gases,
such as H2S, SO2, NH3, HNO3, and Cl2, may be present, or in
locations subject to high temperature or humidity. Doing so may
damage the Switch/Indicator due to contact failure or corrosion.
• Do not use the Switch/Indicator submersed in oil or water, or in
locations continuously subject to splashes of oil or water. Doing so
may result in oil or water entering and damaging the Switch/
Indicator.
• Do not use or keep the Switch/Indicator under the following
conditions:
• Subject to severe temperature changes.
• Subject to high humidity or condensation.
• Subject to severe vibration or shock.
• Where direct rays of the sun strike.
• Where sea breeze may be present.
• Make sure that a rubber washer is present between the Operation
Unit and the panel. In models with IP69K, make sure the rubber
bush of the Operation Unit is properly attached.
Otherwise, the specifications of the protective structure may not be
satisfied.
• Do not apply excessive force to the Switch or wirings. Damage or
deformation of the Switch Block could cause an improper contact
or a loss of safety.
• Use an appropriate wiring and crimp terminals (hereinafter, called
ferrule terminals).
• Exercise caution to avoid wiring errors when connecting the
terminals.
• To prevent wiring materials from smoking or ignition, confirm wire
ratings and use the wiring materials given in the following table.
A22NE-PD
Safety Precautions
28
A22NE-P
A22NE-PD
• Do not insert more than one wire into each terminal insertion hole.
• Do not mount A22N-P or A22NE-P Push-In Plus terminal switch
blocks on A22N screw terminal blocks. Doing so may result in
unsatisfactory performance.
• When mounting on a device with high airtightness, test operation
in advance. There is a risk that the negative pressure will prevent
the Operation Unit of from returning.
• In the case of loads where an inrush current occurs when the
contact is opened or closed, the durability may reduce due to
extreme wear on the contacts.
If necessary, insert a contact protection circuit.
Precautions for Correct Use
Wiring
1. Connecting Wires to the Push-In Plus Terminal Block
Part Names of the Terminal Block
Terminal (insertion) hole
A22NE-P
Release hole
Terminal (insertion) hole
Connecting Wires with Ferrules and Solid Wires
• Insert the solid wire or ferrule straight into the terminal block until
the end strikes the terminal block. The angle should be
approximately 6°.
• If a wire is difficult to connect because it is too thin, use a flat-blade
screwdriver in the same way as when connecting stranded wires.
A22E
Approx. 6˚
Ferrule or solid wire
Approx. 6˚
Common Accessories and Tools
Common Note
29
The wiring for the Lighting Unit and Switch Block (2 contacts) are the
same as for the Switch Block (1 contact) shown in the above illustration.
A22NE-P
3. Recommended Ferrules and Crimp Tools
Coating peeling amount
Recommend Wire Type
Stripping length
(Ferrules not used)
0.25 to 1.5 mm2/AWG 24 to AWG 16
8 mm
Recommended ferrules
Applicable
wire
(2)
(mm2)
(1)
Approx. 6˚
0.25
24
(3)
0.34
22
Flat-blade screwdriver
Approx. 6˚
The wiring and screwdriver angles for the Lighting Unit and Switch
Block (2 contacts) are the same as for the Switch Block (1 contact)
shown in the above illustration.
2. Removing Wires from the Push-In Plus Terminal Block
0.75
18
1/1.25 18/17
1.25/1.5 17/16
10
AI 0, 25-8
12
AI 0, 25-10
8
10
AI 0, 34-8
Wago
product
H0.25/12
216-301
--H0.34/12
---
--216-302
10
12
AI 0, 34-10
8
10
AI 0, 5-8
H0.5/14
216-201
---
10
12
AI 0, 5-10
H0.5/16
216-241
8
10
AI 0, 75-8
H0.75/14
216-202
10
12
AI 0, 75-10
H0.75/16
216-242
216-203
8
10
AI 1-8
H1.0/14
10
12
AI 1-10
H1.0/16
216-243
8
10
AI 1, 5-8
H1.5/14
216-204
10
12
AI 1, 5-10
H1.5/16
216-244
CRIMPFOX6
CRIMPFOX6T-F PZ6 roto
CRIMPFOX10S
Recommended Crimp Tools
Variocri
mp4
Note: 1. Make sure that the outer diameter of the wire coating is
smaller than the inner diameter of the insulation sleeve of
the recommended ferrule.
2. Make sure that the ferrule processing dimensions conform
to the following figures.
8 to 10 mm
Max. 1.9 mm
Max. 2.6 mm
Recommended Flat-Blade Screwdrivers
Use a flat-blade screwdriver to connect and remove wires.
Use one of the following flat-blade screwdrivers.
The following table shows manufacturers and models as of 2015/Dec.
(2)
Approx. 6˚
20
8
10
Weidmuller
product
(1)
Side view
Approx. 6˚
Front view
(3)
2.5 mm dia.
Flat-blade screwdriver
Common Accessories and Tools
Use the following procedure to remove wires from the terminal block.
The same method is used to remove stranded wires, solid wires, and
ferrules.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole. The angle should be approximately 6°.
2. With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
3. Remove the flat-blade screwdriver from the release hole.
0.5
Phoenix
Contact
product
A22E
Checking Connections
• After the insertion, pull gently on the wire to make sure that it will
not come off and it is securely fastened to the terminal block.
• If you use a ferrule with a conductor length of 10 mm, part of the
conductor may be visible after the ferrule is inserted into the
terminal block, but the product insulation distance will still be
satisfied.
Recommended ferrules
Ferrule
Stripping
conductor length (mm)
length
(Ferrules not
(AWG)
(mm)
used)
A22NE-P
Approx. 6˚
A22NE-PD
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal block.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
The angle should be approximately 6°. If the flat-blade screwdriver
is inserted correctly, you will feel the spring in the release hole.
2. With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until the end strikes the
terminal block.
3. Remove the flat-blade screwdriver from the release hole.
Approx. 6˚
0.4 mm
2.5 mm
The wiring and screwdriver angles for the Lighting Unit and Switch
Block (2 contacts) are the same as for the Switch Block (1 contact)
shown in the above illustration.
Manufacture
Wera
SZS 0,4 × 2,5
SZF 0-0,4 × 2,5 *
Phoenix Contact
0.4 × 2.5 × 75 302
Wiha
AEF.2,5 × 75
Facom
210-719
Wago
SDI 0,4 × 2,5 × 75
Weidmuller
* The SZF 0-0,4 × 2,5 (manufactured by Phoenix Contact) can be
procured through an OMRON exclusive purchase form (XW4Z-00B).
Common Note
Model
ESD 0,40 × 2,5
• After wiring the Switch/Indicator, provide a sufficient insulation
distance.
30
A22NE-P
A22NE-PD
LED Lamps
• A current-limiting resistor is built in the LED lamp, so the
installation of an external resistance is not required.
• Lighting malfunction of the LED lamp
A micro-current of approximately 0.1 mA or less is sufficient to turn
on the LED lamps. Take a countermeasure like adding a resistor
to prevent mis-lighting in parallel to the LED lamp.
The micro-current varies with the machine (leak current or stray
capacity between cables, etc.). Select resistance value and
allowable power consumption that meet the actual current.
(Example of lighting malfunction prevention circuit)
When using a 24-VAC/VDC lighted unit
A22NE-P
X1
LED
lamp
R:10 kΩ (1 W)
Bleeder resistor
X2
Be sure to read the "Safety Precautions" on page 56.
A22E
Common Accessories and Tools
Common Note
31
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) Screw Terminal Block types
A22NE-PD
A22E
Install in 22-dia. or 25-dia. Panel Cutout
Be sure to read the "Safety Precautions" on pages 50 and 56.
Model Number Structure
Model Number Legend (Completely Assembled)
For the most recent information on models that have been certified for
safety standards, refer to your Omron website.
A22NE-P
(When Using a Ring)
• Removal contact blocks provide an easy way of assembling the
emergency stop push button.
• Mounted using either open-type (fork-type) or closed-type
(round-type) crimp terminals.
• Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models).
• A lock plate is provided as a standard feature to ensure that the
control box and switch are not easily separated.
Shipped as a set which includes the Operation Unit, LED
Lamp (lighted model only), Mounting Latches, Switch
Block, and Lock Plate
(Example: A22EL-M-24A-01)
Code
Description
None
Non-lighted
L
Lighted *
* Lighted Emergency
Stop Switches are
available only for the
medium (M). turn-reset
models.
2. Operation Unit size (diameter)/Reset function
Code
Size
40 dia.
S
M
L
30 dia.
40 dia.
60 dia.
Pull-reset
Turn-reset
4. Contacts
Unit position
Number of
Code Switch Blocks
NO
NC
01
0
11
1
02
0
Non-lighted
Lighted
1
2
3
1
2
3
1
NC
---
---
NC
---
Lighting unit
1
NC NO
---
NC NO
Lighting unit
2
NC NC
---
NC NC
Lighting unit
12
1
2
NC NO NC
03
0
3
NC NC NC
---
Note 1. NO: 1a-contact
NC: 1b-contact
2. For details on the unit position, refer to the figure below.
3. LED Lamp voltage
Lighting unit (Direct lighting)
Code
Description Operating Voltage
None
Non-lighted
12 A
24 A
---
6 VAC/DC
6A
Lighted
(LED) *
12 VAC/DC
24 VAC/DC
T1
T2
Description Operating Voltage
Lighted
(LED) *
100 VAC
200 VAC
* Equipped with 24-VAC/DC LED.
5. Configuration
Code
None
B
Configuration
Switch only
Switch with Integrated Control Box
6. Configuration
Code
Configuration
None
Neither “EMO” nor “EMS” printed, arrows engraved in red.
EMO
“EMO” and arrows printed in white.
Common Note
Lighting unit (Voltage-reduction lighting)
Code
Common Accessories and Tools
MP
Description
A22E
1. Lighted/Non-lighted
EMO-RD “EMO” printed in white, arrows engraved in red.
EMS
“EMS” and arrows printed in white.
EMS-RD “EMS” printed in white, arrows engraved in red.
32
A22E
A22NE-PD
Ordering Information
List of Models (Completely Assembled)
Non-lighted Models (Without EMO/EMS Indication)
Appearance
Operation
Degree of Protection
Contact
configuration *1
40-dia. head
Medium Pull-reset
A22E-MP
A22NE-P
30-dia. head
Small Turn-reset
A22E-S
IP65 oil-resistant
models
40-dia. head
Medium Turn-reset
A22E-M
60-dia. head
Large Turn-reset
A22E-L
Set Model
1NC (1)
A22E-MP-01
1NC, 1NO (2)
A22E-MP-11
2NC (2)
A22E-MP-02
1NC (1)
A22E-S-01
1NC, 1NO (2)
A22E-S-11
*2
2NC (2)
A22E-S-02
*2
Color of cap
*2
2NC, 1NO (3)
A22E-S-12
*2
3NC (3)
A22E-S-03
*2
1NC (1)
A22E-M-01
*2
1NC, 1NO (2)
A22E-M-11
*2
2NC (2)
A22E-M-02
*2
2NC, 1NO (3)
A22E-M-12
*2
3NC (3)
A22E-M-03
*2
1NC (1)
A22E-L-01
*2
1NC, 1NO (2)
A22E-L-11
*2
2NC (2)
A22E-L-02
*2
Red
*1. The number in parentheses ( ) indicates the number of switch units.
*2. Models with Korean S-mark certification
Note: Yellow cap models are also available (not for emergency stop use). Contact your OMRON representative.
A22E
Non-lighted Models (With EMO/EMS Indication)
Appearance
Operation
Degree of Protection
Contact
configuration *1
1NC (1)
1NC, 1NO (2)
Common Accessories and Tools
40-dia. head
Medium Turn-reset
With EMO Indication
2NC (2)
2NC, 1NO (3)
3NC (3)
IP65 oil-resistant
models
1NC (1)
1NC, 1NO (2)
40-dia. head
Medium Turn-reset
With EMS Indication
2NC (2)
Common Note
2NC, 1NO (3)
3NC (3)
*1. The number in parentheses ( ) indicates the number of switch units.
*2. Models with Korean S-mark certification
Note: The colors of switch blocks are as follows:
NO (a-contact): Black
NC (b-contact): Red
The above illustration shows the 2NC (2b-contact) configuration.
33
Set Model
A22E-M-01-EMO
Color of cap
*2
A22E-M-01-EMO-RD
A22E-M-11-EMO
*2
A22E-M-11-EMO-RD
A22E-M-02-EMO
*2
A22E-M-02-EMO-RD
A22E-M-12-EMO
*2
A22E-M-12-EMO-RD
A22E-M-03-EMO
*2
A22E-M-03-EMO-RD
A22E-M-01-EMS
*2
A22E-M-01-EMS-RD
A22E-M-11-EMS
*2
A22E-M-11-EMS-RD
A22E-M-02-EMS
*2
A22E-M-02-EMS-RD
A22E-M-12-EMS
*2
A22E-M-12-EMS-RD
A22E-M-03-EMS
A22E-M-03-EMS-RD
*2
Red
A22E
Appearance
Degree of
Protection
Operation
Contact
LED Lamp voltage
configuration *1
6 VAC/VDC
12 VAC/VDC
1NC (1)
40-dia. head
Push-lock Turn-reset
Lighting unit
(Direct lighting)
A22E
1NC, 1NO (2)
40-dia. head
Push-lock Turn-reset
Lighting unit
(Voltage-reduction lighting)
A22E
2NC (2)
1NC (1)
1NC, 1NO (2)
2NC (2)
A22EL-M-6A-01
Color of cap
*2
A22EL-M-12A-01 *2
24 VAC/VDC
A22EL-M-24A-01 *2
6 VAC/VDC
A22EL-M-6A-11
12 VAC/VDC
A22EL-M-12A-11 *2
*2
24 VAC/VDC
A22EL-M-24A-11 *2
6 VAC/VDC
A22EL-M-6A-02
12 VAC/VDC
A22EL-M-12A-02 *2
24 VAC/VDC
A22EL-M-24A-02 *2
100 VAC
A22EL-M-T1-01
200 VAC
A22EL-M-T2-01
100 VAC
A22EL-M-T1-11
200 VAC
A22EL-M-T2-11
100 VAC
A22EL-M-T1-02
200 VAC
A22EL-M-T2-02
*2
Red
A22NE-P
IP65
Set Model
A22NE-PD
Lighted Models
*1. The number in parentheses ( ) indicates the number of switch units.
*2. Models with Korean S-mark certification
Switch with Integrated Control Box
Appearance
Model
1NC (1)
A22E-M-01B *
1NC, 1NO (2)
A22E-M-11B *
2NC (2)
A22E-M-02B *
A22E
Contact configuration (Number of switch blocks)
Note: The A22Z-B101Y Control Box is used.
* Models with Korean S-mark certification
Common Accessories and Tools
Common Note
34
A22E
A22NE-PD
Subassembled .... The Operation Unit, LED Lamp, Mounting Latches, and Switch Blocks can be ordered separately. Use them in
combination for models that are not available as assembled Units. These can also be used as inventory for
maintenance parts.
Non-lighted
Lighted
Operation Unit
Operation Unit
A22NE-P
Mounting Latches
A22E
LED Lamp
LED
Common Accessories and Tools
Switch Blocks *
Screw Terminal Block
Common Note
Lock Plate
* Up to three Switch Blocks can be mounted for multiple contacts.
35
Switch Blocks + Lighting unit
Screw Terminal Block
Lock Plate
A22E
Size
Function
Small (30 dia.)
Sealing capability
Medium (40 dia.)
Large (60 dia.)
Single item order model
A22E-MP
Pull-reset
---
---
A22E-M-EMO
A22E-M-EMO-RD
A22E-S
A22NE-P
A22E-M
IP65 oil-resistant models
A22NE-PD
Operation Unit
Non-lighted
A22E-L
Turn-reset
A22E
A22E-M-EMS
A22E-M-EMS-RD
Lighted
Size
Sealing capability
Single item order model
A22EL-M
Turn-reset
IP65
LED lamp
Appearance
LED light
Standard
Model
6 VAC/VDC
A22-6AR
12 VAC/VDC
A22-12AR
24 VAC/VDC
A22-24AR
Note: For a model with a Lighting unit (Voltage-reduction lighting), use the A22-24AR.
Common Note
Red
Rated voltage
Common Accessories and Tools
Function
Medium (40 dia.)
36
A22E
A22NE-PD
Switch
Non-lighted / Direct lighting
Classification Non-lighted
Direct lighting
Appearance
A22NE-P
Contact specifications/
Configuration (Number of switch blocks)
For Standard
loads
Model
Model
1NC (1)
A22-01M
A22L-01M
1NC, 1NO (2)
A22-11M
A22L-11M
2NC (2)
A22-02M
A22L-02M
Voltage-reduction lighting (100 VAC, 200 VAC)
Classification 100 VAC, Lighted
200 VAC, Lighted
Appearance
A22E
Contact specifications/
Configuration (Number of switch blocks)
For Standard
loads
Model
1NC (1)
A22L-01M-T1
A22L-01M-T2
1NC, 1NO (2)
A22L-11M-T1
A22L-11M-T2
2NC (2)
A22L-02M-T1
A22L-02M-T2
Note: For a model with a Lighting unit (Voltage-reduction lighting), use the A22-24AR.
Common Accessories and Tools
Common Note
37
Model
A22E
Item
Appearance
Contact specifications
1NO (Black)
Switch Blocks
(one contact)
1NC (Red)
2NO (Black)
2NC (Red)
1NC + 1NO
Contact (Black/
Red)
A22-10
Microload
A22-10S
Standard load
A22-01
Microload
A22-01S
Standard load
A22-20
Microload
A22-20S
Standard load
A22-02
Microload
A22-02S
Standard load
A22-11
Microload
A22-11S
Direct lighting
Lighting unit
Remarks
Provided as standard.
Order Switch Blocks only when
adding or replacing them.
Order Switch Blocks only when
adding or replacing them.
A22-TN
Voltage-reduction
lighting
100 VAC
A22-T1
200 VAC
A22-T2
Used when changing the lighting
method.
---
A22-3200
Lock Plate
---
A22Z-3380
Use to fix the lever on the Switch.
A22Z-B101Y
Material: Polycarbonate resin.
When using a Control Box, 2NO,
2NC, or 1NC + 1NO two-contact
Switch Blocks are not supported. *
One hole, yellow box
A22Z-B201Y
Common Accessories and Tools
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 51.
* The A22NZ-B101Y and A22NZ-B201Y Control Box cannot be used in combination with the A22Z-3476-1 90-dia. Legend Plates for Emergency
Stop or the A22Z-EG@ E-stop Shrouds.
A22E
Mounting Latches
Provided as standard.
Order Mounting Latches only when
mounting Switch Blocks or Lighting
Units that are purchased
individually.
Control Boxes
(Enclosures)
A22NE-P
Switch Blocks
(two contacts)
Model
Standard load
A22NE-PD
Accessories (Order Separately)
Common Note
38
A22E
A22NE-PD
Specifications
Certified Standard Ratings
Certified Standards
• UL, cUL (File No. E41515)
6 A at 220 VAC, 10 A at 110 VAC
• TÜV (EN60947-5-1) (Low Voltage Directive)
3 A at 220 VAC
• CCC (GB14048.5)
3 A at 240 VAC, 1.5 A at 24 VDC
Certification
body
Standards
File No.
UL *1
UL508, C22.2 No.14
E41515
EN60947-5-1
Consult your OMRON
(Certified direct opening),
representative for details.
EN60947-5-5
TÜV SÜD
CQC (CCC)
GB14048.5
KOSHA *2
A22NE-P
LED Lamp
Contacts (Standard Load)
Rated current (A)
A22E
10
EN60947-5-1
Note: 1. Only models with NC contacts have a direct opening
mechanism.
2. A fuse is not provided.
*1. UL-certification for CSA C22.2 No. 14 has been obtained.
Certification has been obtained for individual Switch Blocks and
Lighting Units.
*2. Some models have been certified.
Ratings
Rated carry
current (A)
2003010303070635
Consult your OMRON
representative for details.
Rated
voltage (V)
AC15
(Inductive
load)
AC12
(Resistive
load)
24 VAC
10
10
110 VAC
5
10
220 VAC
3
6
380 VAC
2
3
440 VAC
1
2
DC13
(Inductive
load)
DC12
(Resistive
load)
---
---
1.5
10
110 VDC
0.5
2
0.2
0.6
0.1
0.2
---
---
380 VDC
Operating voltage
6 VAC/VDC
6 VAC/VDC ± 5%
12 VAC/VDC
12 VAC/VDC ± 5%
24 VAC/VDC
24 VAC/VDC ± 5%
Current value
Approx. 8 mA
Voltage-reduction lighting
Rated voltage Operating voltage Rated current
24 VDC
220 VDC
Rated voltage
110 VAC
100 VAC
(95 to 115 V)
220 VAC
200 VAC
(190 to 230 V)
Applicable lamp
(BA9S/Base: 13)
LED lamp
A22-24A@
Approx. 8 mA
Note: 1. Rated current values are determined according to the
testing conditions. The above ratings were obtained by
conducting tests under the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
Common Accessories and Tools
2. Minimum applicable load: 10 mA at 5 VDC
Characteristics
Type
Turn-reset
Item
Allowable operating
frequency
Non-lighted model
30 operations/minute (One operation consists of set and reset operations.)
Electrical
30 operations/minute (One operation consists of set and reset operations.)
100 MΩ min. (at 500 VDC)
Contact resistance
100 mΩ max. (initial value)
Between terminals of same polarity
2,500 VAC, 50/60 Hz for 1 min.
Between each terminal and ground
2,500 VAC, 50/60 Hz for 1 min.
Destruction
1000 m/s2
Malfunction
250 m/s2 max. (contact separation within 1 ms)
Mechanical
300,000 operations min. (One operation consists of set and reset operations.)
300,000 operations min. (One operation consists of set and reset operations.)
Vibration resistance
Shock resistance
Common Note
Durability
10 to 55 Hz, 1.5-mm double amplitude (contact separation within 1 ms)
Electrical
Ambient operating temperature *1
-20 to +70°C
Ambient operating humidity
35 to 85% RH
-20 to +55°C
Ambient storage temperature
-40 to +70°C
Degree of protection
IP65 oil-resistant models *2 *3 IP65 *2
Electric shock protection class
Class II
PTI (tracking characteristic)
175
Degree of contamination
3 (EN60947-5-1)
Minimum direct opening stroke
11 mm
Minimum direct opening force
45 N
Conditional short-circuit current
100 A (EN 60947-5-1)
Weight (for a 40-dia. head 1NC/1NO Operation Unit)
Approx. 65 g
Approx. 80 g
*1. With no icing or condensation.
*2. The degree of protection from the front of the panel.
*3. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
39
Non-lighted model
Mechanical
Insulation resistance
Dielectric strength
Pull-reset
Lighted model
-20 to +70°C
IP65 oil-resistant models *2 *3
Approx. 100 g
A22E
A22NE-PD
Operating Characteristics
Item
Turn-reset
Pull-reset
Total travel force (TTF)
44.1 N max.
Return force (RF)
0.25 N·m max. *
58.8 N max.
Total travel (TT)
10 ±1 mm
5.5 ±1 mm
58.8 N max.
* Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Non-lighted (two contacts)
Non-lighted (three contacts)
Switch Blocks
10
16.7
Switch Blocks
A22NE-P
LOC
OPE
N
16.7
M3.5 screws
Lighted (two contacts)
10
20.7
22
Lighting unit
Switch Blocks
Terminal connection
Type
Terminal Connection (BOTTOM VIEW)
1NC, 1NO (two contacts)
2NC (two contacts)
2NC, 1NO (three contacts)
3NC (three contacts)
NO
NC
NC
NC
NC
NO
NC
NC
NC
1
3
1
1
1
1
3
1
1
1
2
4
2
2
2
2
4
2
2
2
Non-lighted
X1
1
X
X
1
4
X2
2
X1
X2
2
1
3
Lighted with
Voltage-reduction
lighting
1
2
X1
1
X
2
X2
Common Accessories and Tools
Lighted with
Direct lighting
X1
1
3
A22E
NC
X
2
4
X2
2
Note: The above terminal connection diagrams are examples of the number of contacts.
Terminal wiring drawings of two-contact Switch Units
A
B
Terminal Connection (BOTTOM VIEW)
2NC (two contacts)
2NO (two contacts)
1NC, 1NO (two contacts)
21
23
23
22
24
24
11
13
11
12
14
12
A
B
Common Note
Type
40
A22E
A22NE-PD
Structure and Nomenclature
Operation Unit
Color: Red
Non-lighted
LED lighting
Lamp
Light source
• LED Lamp
A22NE-P
Switch
}
Mounting Latches
Switch Blocks
Lighting unit
Contact Ratings
10 A at 100 VAC (resistive load)
10 A at 24 VDC (resistive load)
Lighting Method
Non-lighted
Lighted (Direct lighting)
Lighted (Voltage-reduction lighting)
A22E
Lock Plate (Attached with the Operation Unit)
(Refer to the "Mounting the Lock Plate" on page 50 for use.)
Dimensions
(Unit: mm)
Non-lighted Models
Common Accessories and Tools
A22E-MP
A22E-S
Medium Pull-reset (40-dia.) Degree of Protection:
IP65 oil-resistant models
Small Turn-reset (30-dia.) Degree of Protection:
IP65 oil-resistant models
30 dia.
34
34
40 dia.
1.8
1.8
(0.5)
(0.5)
5.9
5.9
54.7
32
54.7
32
A22E-L
Medium Turn-reset (40-dia.) Degree of Protection:
IP65 oil-resistant models
Large Turn-reset (60-dia.)Degree of Protection:
IP65 oil-resistant models
Common Note
A22E-M
2
1.5
2
34
60 dia.
34
40 dia.
1.8
6.5
(0.5)
1.8
18.5
(0.5)
32
5.9
5.9
41.2
54.7
Note: The dimensions are the same as for EMO/EMS
indication models.
Note: Unless otherwise specified, a tolerance of ±0.8 mm applies to all dimensions.
41
32
54.7
A22E
Switch dimensions when mounted to a 2NO (2NC) one-piece
switch block
A22EL-M
Medium Turn-reset (40-dia.) Degree of Protection:
IP65 oil-resistant models
A22NE-PD
Lighted Model
2
1.5
2
24 44
34
40 dia.
57.8
1.8
18.5
(0.5)
32
A22NE-P
6.5
72.7
5.9
41.2
Note: The operation unit is an example for the A22E-M.
54.7
Note: Unless otherwise specified, a tolerance of ±0.8 mm applies to all dimensions.
Accessories (Order Separately)
LED Lamp
A22-6@, 12@, 24@
9.5 dia.
10.6 dia.
20±1.5
A22E
Model indication
BA9S/13
Control Box
A22Z-B101Y (1-hole)
Cable Draw-out Hole
(Top View)
4-4×38 tapping screw
0.3
22.1±0.1 dia.
Mounting Hole
56
41
68
36
2.8±0.1
2-R3
4.3
6.3
10
20.5±0.1
(10×36) 0.6 depression
16±1 dia.
(Bottom lead
draw-out hole)
20
75
41
32
39
Two, mounting holes
69.5
Control Box
A22Z-B201Y (1-hole)
Common Accessories and Tools
Two, 21 dia.
(Side lead
draw-out hole)
Cable Draw-out Hole
(Top View)
Four, M4 Screws
0.3
22.1±0.1 dia.
54
68
36
2.8±0.1
2-R3
4.3
6.3
Two, 19±1 dia.
(Bottom lead draw-out hole)
10
20.5±0.1
(10×36) 0.6 depression
16
30.5
68
40
Two, mounting holes
60
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 51.
Common Note
Mounting Hole
Two, 21 dia.
(Side lead
draw-out hole)
42
A22E
A22NE-PD
Installation
Mounting to the Panel
(1) Preparing the Panel
(2) Mounting the Operation Unit on the Panel
• The panel dimensions are shown below.
• The panel thickness must be 1 to 5 mm.
3.2+0.2
0
• Insert the Operation Unit from the front surface of the panel, insert the Lock
Ring and the Tightening Nut from the terminal side, then tighten the Ring.
Before tightening, check that the rubber washer is present between the
Operation Unit and the panel.
• Align the Lock Ring with the groove in the casing, then insert the Lock Ring so
that its edge is located on the panel side.
• Tighten the Tightening Nut at a torque of 1.0 to 2.0 N·m.
• When using a Lock Ring, replace with the supplied Lock Ring, insert the
projecting part into the lock slot, and then tighten the Tightening Nut.
R0.8 max.
24.1
+0.4
0
22.3 +0.4
0 dia.
22.3 +0.4
0 dia.
A22NE-P
With Lock Ring
25 +0.5
0 dia.
Hold here
Rubber Washer
Tightening Nut
Without Lock Ring
Panel
Projecting
part
• Always use a 25-mm-dia. A22Z-R25 Lock Ring for a 25-mm-dia. hole.
IP65 degree of protection will be lost if the 25-mm-dia. Lock Ring is not used
because of the larger size of a 25-mm-dia. hole.
• When painting or coating the panel, make sure that the specified panel
dimensions apply to the panel after painting or coating.
(3) Mounting the Switch on the Operation Unit
• Insert the Operation Unit into the Switch Unit, aligning the arrow mark inscribed
on the Case with the lever on the Switch Blocks, then move the lever in the
direction indicated by the arrow in the following figure.
Lever
Arrow mark
Operation
Unit
Lock Ring
Panel
1. When the panel cutout dimension is
A22E
25 dia., remove the supplied rubber
washer and mount the 25-dia. Ring as
shown below. (Since the A22Z-R25 is
not attached to the main body, order
separately.) When using a Legend
Plate (Order Separately), do not
remove the rubber washer.
Operation Unit
Rubber washer
(mounted to
Operation Unit)
When not using a
Legend Plate,
remove the rubber
washer.
(4) Removing the Switch
22 dia.
Common Accessories and Tools
• Move the lever in the direction indicated by the arrow in the following figure,
then pull the Operation Unit or the Switch Blocks.
Since the lever has a hole with an inside diameter of 6.5 mm, the lever can
be moved in the specified direction by inserting a screwdriver into the hole
and then moving the screwdriver.
(If required)
Legend Plates for
Emergency Stop
(order separately)
25-dia. Ring
(A22Z-R25)
0.5
1.3
25 dia.
Screwdriver
25 dia.
Panel
22.3 dia.
Lock Ring
Tightening Nut
Assembling the Cap
Common Note
Emergency Stop Switch
• Insert the protrusion of the Tightening Wrench (A22Z-3905) into the Cap slot and then turn to remove the Cap.
43
Protrusion
2. When the panel cutout
dimension is 30 dia., use resin
attachment A22Z-A30. Since it
is not attached to the main
body, order separately.
Operation Unit
Rubber washer
(mounted to
Operation Unit)
30-dia.
Resin Attachment
(A22Z-A30)
Rubber washer
(included)
Mounting
panel
Lock Ring
22.3 dia.
Cap slot
Lock Ring
Tightening Nut
A22E
A22NE-PD
Installing/Replacing the LED Lamp
Installing/Replacing on the Switch
• Grip the lamp with your fingers, then rotate the lamp while pressing it against the Switch.
A22NE-P
Control Box (Enclosure)
(1) Mounting the Switch
(2) Creating a Cable Port Hole
The Standard-size Legend Plate Frame can
be mounted.
Mount the Frame as shown in the following
diagram. Mount the Switch in the same way
as for an ordinary panel.
Place the tip of a screwdriver on the surface
where the cable port hole is to be created
with the cover attached and strike the
screwdriver to punch a hole.
Attempts to punch a hole on the other side
of the case will damage the Box.
(3) Securing the Connector Cable
1. Insert the connector into the cable port hole in the Box and secure
with the Mounting Ring inside the box.
2. Pass the tightening cap through the cable, insert the cable into the
connector, and tighten the tightening cap to secure the cable.
O Ring
Fixing
Ring
Snap-in Legend Plate
Connector
Tightening cap
Cable
A22E
Box
Cable diameter (mm)
A22Z-3500-1
9 to 11 dia.
A22Z-3500-2
Wiring
(1) Installing the Switch Blocks
(2) Removing the Switch Blocks
Wiring Round Crimp Terminals
• Hook the small protrusion on the Mounting Latch
into the groove on the other side of the lever, then
push up the Switch Block in the direction indicated
by the arrow in the figure below.
• Insert a screwdriver between the Mounting Latch
and the Switch Block, then push down the screwdriver in the direction indicated by the arrow in the
following figure.
• Loosen the terminal screw from the Switch
Unit until it completely comes off the groove,
insert a screwdriver as shown in the following
figure, then push up the washer in the direction indicated by the arrow to temporarily
secure it.
Now, a round crimp terminal can be connected. After inserting the terminal, tighten the
screws to complete wiring.
Washer
Common Accessories and Tools
Installing/Removing the Switch Blocks
Connector
7 to 9 dia.
Lever
Screwdriver
Screw
Screwdriver
Protrusion
Use either of the following screwdrivers.
Switch Blocks
Flat-head screwdriver
Phillips screwdriver
3 to 6 mm
Common Note
Mounting Latches
3 to 6 mm dia.
44
A22E
A22NE-PD
Safety Precautions
Be sure to read the precautions for All PushButton Switches in the website at:http://www.ia.omron.com/.
Indication and Meaning for Safe Use
LED Lamps
Warning
Indicates a potentially hazardous
situation that, if not avoided, could
result in serious injury or death.
Additionally there may be significant
property damage.
CAUTION
Indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury or in
property damage.
A22NE-P
Supplementary comments on what to
do or avoid doing, to use the product
safely.
Precautions for
Safe Use
WARNING
(Circuit example)
Do not perform wiring with power supplied to the Switch/
Indicator. Do not touch the terminals or other charged
parts while power is being supplied. Doing so may result
in electric shock.
In case of using 24 VAC/VDC, Direct lighting
X1
Caution
LED
lamp
A22E
If the Operation Unit is separated from the Socket Unit, the
equipment will not stop, creating a hazardous condition.
Secure the lever on the Socket Unit by using the
A22Z-3380 Lock Plate so that the Operation Unit cannot
be easily separated from the Socket Unit.
(Refer to “Mounting the Lock Plate” at the below.)
R:10kΩ (1W)
Bleeder resistor
X2
• Do not use a lamp that does not satisfy the rating.
Using the Microload
Precautions for Correct Use
Mounting the Lock Plate
1. Confirm that the lever on the Mounting Latch is on the side where
the Operation Unit is secured and then insert the protrusion on the
Lock Plate into the hole in the lever on the Mounting Latch.
2. Press the hole on the Lock Plate onto the protrusion on the
Mounting Latch until it clicks into place.
Lock Plate
2
1
Contact failure may occur if a Switch designed for a standard load is
used to switch a microload. Use Switches within the application
ranges shown in the following graph. Even within the application
range, insert a contact protection circuit, if necessary, to prevent the
reduction of life expectancy due to extreme wear on the
contacts caused by loads where inrush current occurs when the
contact is opened and closed.
The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ 60) (conforming to JIS C5003).
The equation, λ 60 = 0.5 x 10−6/time indicates that the estimated
malfunction rate is less than 1/2,000,000 with a reliability level of 60%.
Voltage (V)
Common Accessories and Tools
Lever
• The LED current-limiting resistor is built-in, so internal resistance is
not required.
• If commercially available LEDs are used, select the ones that meet
the following conditions:
Base: BA9S/13
Overall length: 26 mm max.
Power consumption: 2.6 W max.
When DC-specific LEDs are used, wire the Switch so that the X1
terminal is positive.
• Mis-lighting of the LED
The LED lights with approx. 0.1 mA or less of micro-current. Take
a countermeasure like adding a resistor to prevent mis-lighting in
parallel to the LED.
The micro-current varies with the machine (leak current or stray
capacity between cables, etc.). Select resistance value and
allowable power consumption that meet the actual current.
Operation
Unit
0.16 mA
24
Mounting Latch
Microload area
Common Note
• Terminal screws must be Phillips or slotted M3.5 screws with a
square washer.
• The tightening torque is 1.08 to 1.27 N·m.
• Single wires, stranded wires, and crimp terminals can be
connected to the Switch.
• Applicable Wiring Materials:
Twisted strands: 2 mm2 max.
Solid wire: 1.6 mm dia. max.
8 mm max.
16.0 mm max.
Crimp Terminals with
Insulating Sheaths
8 mm dia. max.
16.0 mm max.
8 mm max.
20.2 mm max.
8 mm dia. max.
20.2 mm max.
• After wiring the Switch, maintain an appropriate clearance and
creepage distance.
45
Area of
use
Standard
load area
Wiring
Naked Crimp Terminals
100 mA
1.6 mA
30
12
Invalid
area
5
0
0.1
1 mA
10 mA
1
10
100
1,000
Current (mA)
Be sure to read the "Safety Precautions" on page 56.
A22NE-PD/A22NE-P/A22E
Ordering Information
Common to Push-in Plus Terminal Block types (A22NE-PD/A22NE-P)/Screw Terminal Block types (A22E)
Item
A22Z-3476-1
Used in combination with the rubber packing when the level of
protection is to be met between panels. *1 *3
60-dia. black letters on yellow
background
A22Z-3466-2
Used in combination with the rubber packing when the level of
protection is to be met between panels. *1
Hole Plug
Round
A22Z-3530
Used for covering the panel cutouts for future panel expansion.
Black color.
Connectors
Applicable cable
diameter
25-dia. Ring
---
A22Z-R25
Use when mounting to a panel with a 25-dia. hole. (Refer to page
15, 31, and 48).
Material: Rubber, Level of protection: IP65
30-dia.
Resin Attachment
---
A22Z-A30
Use when mounting to a panel with a 30-dia. hole. (Refer to page
15, 31, and 48).
A rubber packing is provided with the product.
Lock Ring
---
A22Z-3360
The body is equipped with a Lock Ring.
This Lock Ring is used when a more secure lock feature is
required. (Refer to page 15 and 31).
Tightening Tool
---
A22Z-3905
Used for tightening the tightening nut from the back side of the
panel, and for removing the cap in lighted models.
E-stop Shroud for
EMO, Yellow
---
A22Z-EG1
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and
legend plate for EMERGENCY OFF come as a set. Use with an
A22E Emergency Stop Switch (for emergency shutoff) *2 *3
E-stop Shroud for
EMO, Yellow
Legend plate for EMERGENCY
OFF is not included.
A22Z-EG10
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI S2 compatibility. Use with an A22E with EMO indication.
(for emergency off) *3
E-stop Shroud for
EMS, White
---
A22Z-EG1-W
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and
legend plate for EMERGENCY STOP come as a set. Use with
an A22E Emergency Stop Switch. (for emergency stop) *2 *3
E-stop Shroud for
EMS, White
Legend plate for EMERGENCY
STOP is not included.
A22Z-EG10-W
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI S2 compatibility. Use with an A22E with EMS indication.
(for emergency stop) *3
Spacer Unit is not included.
A22Z-EG2
One Spacer Unit is included.
A22Z-EG21
Two Spacer Units are included.
A22Z-EG22
---
A22Z-EG3
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and
legend plate for EMERGENCY OFF come as a set. Use with an
A22E Emergency Stop Switch.(for emergency shutoff) *2 *3
A22Z-R
Used together with accessories.
Contains 10 packings.
E-stop Shroud,
Yellow
E-stop Shroud for
EMO, Yellow
Rubber Packing
-
A22Z-3500-1
9 to 11 dia.
A22Z-3500-2
Plastic connector used to extend a cable from the Switch Box.
(Refer to page 15, 32, and 49).
SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI
S2-compatible Shroud. (for emergency shutoff) *2 *3
Use together with an A22E Emergency Stop Switch.
*1. If you use Legend Plates for Emergency Stop, set the thickness of the panels between 1 to 4 mm.
*2. These Shrouds are for use with the equipment only that conforms to SEMI standards. Do not use them for any other applications (e.g.
emergency stop switches for machines or devices such as Machine tools, Printing presses, Industrial machinery, etc).
*3. The Control Boxes cannot be used in combination with the A22Z-3476-1 Legend Plates for Emergency Stop or the A22Z-EG@ E-stop Shrouds.
Common Note
90-dia. black letters on yellow
back-ground
7 to 9 dia.
Remarks
Common Accessories and Tools
Used in combination with the rubber packing when the level of
protection is to be met between panels. *1
A22E
Model
A22Z-3466-1
A22NE-P
Classification
60-dia. black letters on yellow
back-ground
Legend Plates for
Emergency Stop
Appearance
A22NE-PD
Common Accessories and Tools (Order Separately)
Note: 1. Accessories for A22Z-EG1: one “EMERGENCY OFF” label, two rubber packings, and one lock ring
2. Accessories for A22Z-EG10: one rubber packing and one lock ring (without label)
46
A22NE-PD/A22NE-P/A22E
A22NE-PD
Dimensions
(Unit: mm)
Screw Terminal Block Type/Push-in Plus Terminal Block Type
Hole Plug
Round A22Z-3530
30-dia. Resin Attachment
A22Z-A30
6
34.7 dia.
2.8
30 dia.
6.1
3.8
20.5
1
13
22.2 dia.
2.5
A22NE-P
Legend Plates for Emergency Stop
A22Z-3476-1 (90 dia.)
A22Z-3466-1 (60 dia.)
90 dia.
60 dia.
60 dia.
Black letters
Black letter
Black letters
Yellow
Yellow
Yellow
22.2 dia.
22.2 dia.
t1
t1
Lock Ring
A22Z-3360
25-dia. Ring
A22Z-R25
2
1
20.5
A22E
30 dia.
22 dia.
24.8 dia.
27 dia.
22.2 dia.
0.5
Material: NBR (black)
2.8
Material: Nickel plated on iron
4.5
25 dia.
19.2 dia.
30 dia.
21.2 dia.
Common Accessories and Tools
Tightening Tool
A22Z-3905
20
90
2
Rubber Packing
A22Z-R
Common Note
0.5
22 dia.
27 dia.
Connector
A22Z-3500
27 dia.
24 dia.
22
28 dia.
10
47
A22Z-3466-2 (60 dia.)
29 max.
1.3
t1
22.2 dia.
A22NE-PD/A22NE-P/A22E
A22NE-PD
Common E-stop Shrouds
A22Z-EG1, A22Z-EG1-W, A22Z-EG10, A22Z-EG10-W
Screw Terminal Block type
Mounting a 1-pole Switch Unit
52.2 max.
38
75
63
22.2 dia
75 min.
(Determined by the
height of the Switch
surface in the
lock position.)
2.8
5R
78 dia.
20.5
30 40
90 dia.
A22E-M
Switch Unit
Panel
2.5+0.5
-1.5
Note: 1. The dimensions of the
Shroud conform to the
specifications of the
SEMATECH
Application Guide for
SEMI S2-93.
2. The Shroud is not
provided with the
Switch.
8
Push-in Plus Terminal Block type
Mounting a 1-pole Switch Unit
38.5
Push-in Plus Terminal Block type
Mounting a 2-pole Switch Unit
38
37 max.
A22NE-P
33 dia.
52.2 max.
R5
30 dia.
40 dia.
1-pole
Switch Unit
2-pole
Switch Unit
Panel
Switch Mounting Dimension 2.3 +0.5
-1.5
8.5
Panel
Switch Mounting
2.3 +0.5
-1.5
Dimension
A22E
“EMERGENCY STOP” is indicated
on A22Z-EG1-W.
Legend plate is not provided with
A22Z-EG10 and A22Z-EG10-W.
EMERGENCY OFF
inscription plate (t=1)
Rubber packing (t=0.5)
Sunken
section,
0.2
Panel Cutout Dimensions
Switch guard
24.2±0.2
R1.7+0.1
0
Model
A22NE-PD series
A22NE-P series
A22E series
Allowable panel
thickness [mm]
1 to 1.8
1 to 2.0
2 1
Rubber packing (t=0.5)
Mounting panel
Locking ring
Common Accessories and Tools
22.3+0.4
0 dia.
Common Note
48
A22NE-PD/A22NE-P/A22E
A22NE-PD
E-stop Shrouds
A22Z-EG2, A22Z-EG21, A22Z-EG22
105 dia.
98 dia.
3
35
12
79 dia.
2.8
20.6
M90
Detents
inside
(One on
each side)
A22NE-P
22.2 dia.
2R
During spacer attachment
With 1 Spacer
Spacer
With 2 Spacers
The number of spacers depends on the model
A22Z-EG2 : No Spacer
A22Z-EG21 : 1 Spacer
A22Z-EG22 : 2 Spacers
Screw Terminal Block Type
Mounting a 1-pole Switch Unit *
Spacers
Screw Terminal Block Type
Mounting a 2-pole Switch Unit *
Panel Cutout Dimensions
90.3 +0.4
0 dia.
2b One-Piece
Contact Unit
1b Contact Unit
5.5 +0.2
0
A22E
10
13
Panel
20
23
Position of
detent
notch
Position of
detent
notch
95 +0.2
0
Panel
Common Accessories and Tools
Note: 1. The dimensions of the Shroud conform to the
specifications of the SEMATECH Application Guide
for SEMI S2-93.
2. The Shroud is not provided with the Switch.
3. Tighten to a torque of 1.96 to 2.94 N⋅m.
4. The allowable panel thicknesses are as follows:
Without Spacers: t=1.3 to 22.5 mm
With 1 Spacer:
t=1.3 to 12.5 mm
With 2 Spacers: t=1.3 to 2.5 mm
Panel
Panel
88 max.
Push-in Plus Terminal Block Type
Mounting a 1-pole Switch Unit *
105 max.
Push-in Plus Terminal Block Type
Mounting a 2-pole Switch Unit *
2b One-Piece
Contact Unit
1b Contact Unit
Position of
detent
notch
Position of
detent
notch
Panel
72 max.
Panel
88 max.
* These are the dimension from the front of the panel when the Switch Unit is attached.
Common Note
49
A22NE-PD/A22NE-P/A22E
Screw Terminal Block Type
Mounting a 1-pole Switch Unit
78 min. (Determined by the
height of the Switch
surface in the lock position.)
90 dia.
C
Screw Terminal Block Type
Mounting a 2-pole Switch Unit
71.2 max.
52.2 max.
38
38
A22NE-PD
E-stop Shroud
A22Z-EG3
2.8
a.
20.5
1-pole
Switch Unit
33
di
22.2 dia.
Switch Mounting
+0.5
2.5 -1.5
Dimension
Panel
Switch Mounting
2.5 +0.5
-1.5
Dimension
C-C
Push-in Plus Terminal Block Type
Mounting a 1-pole Switch Unit
38.8
C-C
Push-in Plus Terminal Block Type
Mounting a 2-pole Switch Unit
37 max.
52.2 max.
38.8
1-pole
Switch Unit
2-pole
Switch Unit
Panel
Panel
A22E
Switch Mounting
Dimension
2.5 +0.5
-1.5
Switch Mounting
2.5 +0.5
Dimension
-1.5
Legend Plate
(Provided with the Switch Guard)
Rubber Packing
(t=0.5, Rubber Packing)
Panel Cutout Dimensions
22.3 dia.+0.4
0
Set model number
A22Z-EG3
Portion A:
Indented part
E-Stop Shroud
24.2±0.2
Portion B
Panel
Locking Ring
(Rubber Packing)
Mounting Nut
(Provided with the Operation Unit)
Model
Allowable
panel
thickness
[mm]
A22NE-PD series
1 to 1.8
A22NE-P series
A22E series
1 to 2.0
Common Accessories and Tools
1.7R+0.1
0
Rubber Packing
(t=0.5, Rubber Packing)
Note: 1. The dimensions of the Shroud conform to the
specifications of the SEMATECH Application Guide for
SEMI S2-93.
2. The Shroud is not provided with the Switch.
A22NE-P
C
2-pole Switch Unit
Panel
Common Note
50
A22E/A22NE-P
A22NE-PD
Safety Precautions
Be sure to read the precautions for All PushButton Switches in the website at:http://www.ia.omron.com/.
Indication and Meaning for Safe Use
Precautions
for Safe Use
Supplementary comments on what to do
or avoid doing, to use the product safely.
Precautions for Correct Use
Mounting
A22NE-P
• Always make sure that the power is turned OFF before wiring the
Switch. Also, do not touch the terminals or other current-carrying
ports while power is being supplied. Electric shock may occur.
• Do not tighten the tightening nut more than necessary by using
tools such as pointed-nose pliers. Doing so could damage the
tightening nut. (The tightening torque is 1.0 to 2.0 N·m.)
• Recommended panel thickness: 1 to 5 mm.
• When mounting the caps after changing the LED or the caps,
tighten the caps at a tightening torque of 0.49 to 0.78 N·m.
Operating Environment
• This model is designed with a protective structure so that it will not
sustain damage if it is subjected to water from any direction to the
front of the panel.
• The Switch is intended for indoor use only. Using the Switch
outdoor may cause it to fail.
Others
A22E
• If the panel is to be coated, make sure that the panel meets the
specified dimensions after coating.
• Due to the structure of the Switch, severe shock or vibration may
cause malfunctions or damage to the Switch.
Also, most Switches are made from resin and will be damaged if
they come into contact with sharp objects. Particularly scratches
on the Operation Unit may create visual and operational
obtrusions.
Handle the Switches with care, and do not throw or drop them.
Common Accessories and Tools
Do not allow the
Switch to drop and hit
the floor.
Do not place or drop
heavy objects on the
Switch.
Common Note
51
Do not operate the
Switch with hard or
sharp objects.
Hammer
Screwdriver
OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA • 847.843.7900 • 800.556.6766 • automation.omron.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • automation.omron.com
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
Ciudad de México • 52.55.5901.4300 • 01.800.386.6766 • mela@omron.com
OMRON ARGENTINA • SALES OFFICE
Buenos Aires, Argentina • +54.11.4521.8630 • +54.11.4523.8483
mela@omron.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
San Pedro Garza García, N.L. • 81.12.53.7392 • 01.800.386.6766 • mela@omron.
com
OTHER OMRON LATIN AMERICA SALES
+54.11.4521.8630 • +54.11.4523.8483 • mela@omron.com
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Eugenio Garza Sada,León, Gto • 01.800.386.6766 • mela@omron.com
Controllers & I/O
• Machine Automation Controllers (MAC) • Motion Controllers
• Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O
Authorized Distributor:
Robotics
• Industrial Robots • Mobile Robots
Operator Interfaces
• Human Machine Interface (HMI)
Motion & Drives
• Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems
• Frequency Inverters
Vision, Measurement & Identification
• Vision Sensors & Systems • Measurement Sensors • Auto Identification
Systems
Sensing
• Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors
• Rotary Encoders • Ultrasonic Sensors
Safety
• Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems
• Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices
• Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays
Control Components
• Power Supplies • Timers • Counters • Programmable Relays
• Digital Panel Meters • Monitoring Products
Switches & Relays
• Limit Switches • Pushbutton Switches • Electromechanical Relays
• Solid State Relays
Software
• Programming & Configuration • Runtime
A2633I-E3-06