0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CP1L-EM30DT1-D

CP1L-EM30DT1-D

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Cpu Unit, 18 I/p, 12 O/p, 24V, Pnp; No. Of Inputs:18Inputs; No. Of Outputs:12Outputs; Supply Voltage...

  • 数据手册
  • 价格&库存
CP1L-EM30DT1-D 数据手册
CP series CP1L CPU Unit CP1L-EM@@D@-D/CP1L-EL@@D@-D CP1L-M@@DR-A/CP1L-L@@DR-A The Standard Package-type PLC • "CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port. • "CP1L-M" and "CP1L-L" has a standard-feature USB port. • Function blocks (FB) allow you to build up modular structure and programming of ladder diagrams. CP1L-L CPU Units with 10 Points CP1L-EL CPU Units with 20 Points CP1L-EM CPU Units with 40 Points CP1L-M CPU Units with 60 Points Features • Complete with a standard-feature Ethernet port. "CP1L-EM" and "CP1L-EL" only. • Pulse output for two axes. Advanced power for high-precision positioning control. • High-speed Counters. Differential phases for four axes. • Eight interrupt inputs are built in. Faster processing of approximately 500 instructions speeds up the entire system. • Serial Communications. Two ports. Select Option Boards for either RS-232C or RS-485 communications. • USB Peripheral Port. Another standard feature. • The Structured Text (ST) Language. Makes math operations even easier. • Can be used for the CP1W series and CJ series Unit. The extendibility of it is preeminently good. • LCD displays and settings. Enabled using Option Board. 1 CP1L Ordering Information ● International Standards • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. • Contact your OMRON representative for further details and applicable conditions for these standards. ■ CPU Units Specifications CPU Unit CP1L-EM CPU Units with 40 Points CP1L-EM CPU Units with 30 Points CP1L-EL CPU Units with 20 Points CP1L-M CPU Units with 60 Points CP1L-M CPU Units with 40 Points CP1L-M CPU Units with 30 Points CP1L-L CPU Units with 20 Points CPU type Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 5K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 10K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 5K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Power supply Output method Inputs Outputs Relay output DC power supply DC power supply Transistor output (sinking) 24 16 CP1L-EM40DT1-D Relay output CP1L-EM30DR-D 18 12 Transistor output (sinking) 12 8 AC power supply CP1L-M60DR-A CP1L-M60DT-A AC power supply AC power supply CP1L-M60DR-D Transistor output (sourcing) CP1L-M60DT1-D Relay output CP1L-M40DR-A Transistor output (sinking) CP1L-M40DT-A 24 16 CP1L-M40DR-D CP1L-M40DT-D Transistor output (sourcing) CP1L-M40DT1-D Relay output CP1L-M30DR-A Transistor output (sinking) CP1L-M30DT-A Transistor output (sinking) 18 12 CP1L-M30DR-D CP1L-M30DT-D Transistor output (sourcing) CP1L-L20DR-A Transistor output (sinking) CP1L-L20DT-A Transistor output (sinking) Transistor output (sourcing) UC1, N, L, CE UC1, N, L, CE UC1, N, L, CE CP1L-M30DT1-D Relay output Relay output DC power supply 24 CP1L-M60DT-D Relay output DC power supply 36 Transistor output (sinking) Transistor output (sinking) CE CP1L-EL20DT1-D Relay output Relay output DC power supply CP1L-EL20DT-D Transistor output (sinking) Relay output CE CP1L-EL20DR-D Transistor output (sourcing) DC power supply CP1L-EM30DT-D CE CP1L-EM30DT1-D Relay output AC power supply CP1L-EM40DT-D Transistor output (sourcing) Transistor output (sinking) Standards CP1L-EM40DR-D Transistor output (sourcing) DC power supply Model 12 8 CP1L-L20DR-D CP1L-L20DT-D UC1, N, L, CE CP1L-L20DT1-D Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. 2 CP1L Specifications CPU Unit CP1L-L CPU Units with 14 Points CP1L-L CPU Units with 10 Point CPU type Memory capacity: 5K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Memory capacity: 5K steps High-speed counters: 100 kHz, 4 axes Pulse outputs: 100 kHz, 2 axes (Models with transistor outputs only) Power supply AC power supply Output method AC power supply Model Relay output CP1L-L14DR-A CP1L-L14DT-A Transistor output (sinking) 8 6 CP1L-L14DR-D CP1L-L14DT-D Transistor output (sourcing) CP1L-L14DT1-D Relay output CP1L-L10DR-A Transistor output (sinking) CP1L-L10DT-A Relay output DC power supply Outputs Transistor output (sinking) Relay output DC power supply Inputs 6 4 CP1L-L10DR-D Transistor output (sinking) CP1L-L10DT-D Transistor output (sourcing) CP1L-L10DT1-D Standards UC1, N, L, CE UC1, N, L, CE Note: 1. CP1L PLCs are supported by CX-Programmer version 7.1 or higher, except for EM40, EM30, EL20, M60, and L10 CPU Units. CP1L-EM40/EM30/EL20 CPU Units are supported by CX-Programmer version @@@ or higher. The 60-point CPU Units are supported by CX-Programmer version 7.2 or higher. The 10-point CPU Units are supported by CX-Programmer version 7.3 or higher. Update The CX-Programmer version automatically from the website using CX-Programmer version 7.0 (included with CX-One version 2.0). 2. Purchase an Option Unit (sold separately) if you will use RS-232C, RS-422A/485, Ethernet, or LCD. ■ Options for CPU Units Name Specifications Model Standards CP1W-CIF01 RS-232C Option Board UC1, N, L, CE RS-422A/485 Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *1 RS-422A/485 (Isolated-type) Option Board CP1W-CIF11 CP1W-CIF12 UC1, N, L, CE Ethernet Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *1 *2 CP1W-CIF41 UC1, N, L, CE Analog Input Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 2 analog inputs. 0-10V(Resolution:1/4000), 0-20mA (Resolution:1/2000). CP1W-ADB21 CE Analog Output Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 2 analog outputs. 0-10V (Resolution:1/4000). CP1W-DAB21V CE Analog I/O Option Board Can be mounted in either CPU Unit Option Board slot 1 or 2. *3 2 analog inputs. 0-10V(Resolution:1/4000), 0-20mA(Resolution:1/2000). 2 analog outputs. 0-10V (Resolution:1/4000). CP1W-MAB221 CE LCD Option Board Can be mounted only in the CPU Unit Option Board slot 1. *1 CP1W-DAM01 UC1, L, N, CE Memory Cassette Can be used for backing up programs or auto-booting. CP1W-ME05M UC1, N, L, CE *1. Cannot be used for the CP1L-L10. *2. When using CP1W-CIF41 Ver.1.0, one Ethernet port can be added. *3. CP1L-EM / EL only. 3 CP1L ■ Programming Devices Specifications Name FA Integrated Tool Package CX-One Lite Version 4.@ Number of licenses CX-One Lite is a subset of the complete CX-One package that provides only the Support Software required for micro PLC applications. CX-One Lite runs on the following OS. OS: Windows XP (Service Pack 3 or higher), Vista or 7 Note: Except for Windows XP 64-bit version. Model Media Standards 1 license CD CXONE-LT01C-V4 --- 1 license *1 DVD *2 CXONE-AL01D-V4 --- CX-One Lite Ver. 4.@ includes Micro PLC Edition CXProgrammer Ver. 9.@. FA Integrated Tool Package CX-One Ver. 4.@ CX-One is a package that integrates the Support Software for OMRON PLCs and components. CX-One runs on the following OS. OS: Windows XP (Service Pack 3 or higher), Vista or 7 Note: Except for Windows XP 64-bit version. CX-One Ver. 4.@ includes CX-Programmer Ver. 9.@. Programming Device Connecting Cable for CP1W-CIF01 RS-232C Option Board *3 USB-Serial Conversion Cable *3 Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m) Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m) For anti-static connectors XW2Z-200S-CV XW2Z-500S-CV Connects Personal Computers, D-Sub 9-pin (Length: 2.0 m) XW2Z-200S-V Connects Personal Computers, D-Sub 9-pin (Length: 5.0 m) XW2Z-500S-V USB-RS-232C Conversion Cable (Length: 0.5 m) and PC driver (on a CD-ROM disc) are included. Complies with USB Specification 1.1 On personal computer side: USB (A plug connector, male) On PLC side: RS-232C (D-sub 9-pin, male) Driver: Supported by Windows 98, Me, 2000, and XP CS1W-CIF31 --- N Note: 1. CP1L PLCs are supported by CX-Programmer version 7.1 or higher, except for EM40, EM30, EL20, M60, and L10 CPU Units. CP1L-EM40/EM30/EL20 CPU Units are supported by CX-Programmer version @@@ or higher. The 60-point CPU Units are supported by CX-Programmer version 7.2 or higher. The 10-point CPU Units are supported by CX-Programmer version 7.3 or higher. Update The CX-Programmer version automatically from the website using CX-Programmer version 7.0 (included with CX-One version 2.0). 2. The CX-One and CX-One Lite cannot be simultaneously installed on the same computer. *1. Multi licenses are available for the CX-One (3, 10, 30 or 50 licenses). *2. The CX-One is also available on CD (CXONE-AL@@C-V4). *3. Cannot be used with a peripheral USB port. To connect to a personal computer via a peripheral USB port, use commercially-available USB cable (A or B type, male). The following tables lists the Support Software that can be installed from CX-One CX-One Lite Ver.4.@ Support Software in CX-One Support Software in CX-One CX-One Lite Ver.4.@ CX-One Ver.4.@ Yes Micro PLC Edition CX-Programmer Ver.9.@ Yes No CX-Drive Ver.2.@ Yes CX-Programmer Ver.9.@ No Yes CX-Process Tool Ver.5.@ No Yes CX-Integrator Ver.2.@ Yes Yes Faceplate Auto-Builder for NS Ver.3.@ No Yes Yes Switch Box Utility Ver.1.@ Yes Yes CX-Designer Ver.3.@ Yes CX-Protocol Ver.1.@ No Yes NV-Designer Ver.1.@ Yes Yes CX-Simulator Ver.1.@ Yes Yes CX-Thermo Ver.4.@ Yes Yes CX-Position Ver.2.@ No Yes CX-ConfiguratorFDT Ver.1.@ Yes Yes CX-Motion-NCF Ver.1.@ No Yes CX-FLnet Ver.1.@ No Yes CX-Motion-MCH Ver.2.@ No Yes Network Configurator Ver.3.@ Yes Yes CX-Motion Ver.2.@ No Yes CX-Server Ver.4.@ Yes Yes Note: For details, refer to the CX-One Catalog (Cat. No: R134). 4 CX-One Ver.4.@ CP1L ■ Expansion Units Name Output method Inputs Outputs Model Relay Transistor (sinking) 24 16 CP1W-40EDT Transistor (sourcing) CP1W-32ER Transistor (sinking) --- 32 CP1W-32ET Transistor (sourcing) N, L, CE CP1W-32ET1 Relay CP1W-20EDR1 Transistor (sinking) 12 8 CP1W-20EDT Transistor (sourcing) U, C, N, L, CE CP1W-20EDT1 Relay CP1W-16ER Transistor (sinking) --- 16 CP1W-16ET Transistor (sourcing) N, L, CE CP1W-16ET1 --- 8 Relay Transistor (sinking) --- Transistor (sourcing) Analog Input Unit N, L, CE CP1W-40EDT1 Relay Expansion I/O Units Standards CP1W-40EDR Analog (resolution: 1/6000) 4 --- CP1W-8ED 8 CP1W-8ER CP1W-8ET 8 U, C, N, L, CE CP1W-8ET1 --- CP1W-AD041 UC1, N, L, CE Analog Output Unit CP1W-DA041 2 CP1W-DA021 UC1, CE 2 1 CP1W-MAD11 U, C, N, L, CE 8 (I/O link input bits) 8 (I/O link input bits) CP1W-SRT21 Analog (resolution: 1/6000) Analog I/O Unit Analog (resolution: 1/6000) CompoBus/S I/O Link Unit --- Temperature Sensor Unit 4 --- 2 thermocouple inputs CP1W-TS001 4 thermocouple inputs CP1W-TS002 2 platinum resistance thermometer inputs CP1W-TS101 4 platinum resistance thermometer inputs CP1W-TS102 U, C, N, L, CE CP1L (L Type) CPU Units with 10 points do not support Expansion Units. ■ I/O Connecting Cable Name Specifications Model I/O Connecting Cable 80 cm (for CP1W/CPM1A Expansion Units) CP1W-CN811 Standards UC1, N, L, CE Note: An I/O Connecting Cable (approx. 6 cm) for horizontal connection is provided with CP1W/CPM1A Expansion Units. ■ Optional Products, Maintenance Products and DIN Track Accessories Name DIN Track End Plate Specifications Model Length: 0.5 m; Height: 7.3 mm PFP-50N Length: 1 m; Height: 7.3 mm PFP-100N Length: 1 m; Height: 16 mm PFP-100N2 There are 2 stoppers provided with CPU Units and I/O Interface Units as standard accessories to secure the Units on the DIN Track. PFP-M Standards --- 5 CP1L General Specifications Item Type AC power supply models Model CP1L-@@@-A DC power supply models CP1L-@@@-D Power supply 100 to 240 VAC 50/60 Hz 24 VDC Operating voltage range 85 264 VAC 20.4 to 26.4 VDC Power consumption 50 VA max. (CP1L-M60/-M40/-M30@@-A) (See page 27) 30 VA max. (CP1L-L20/-L14/-L10@@-A) 20 W max. (CP1L-M60/-M40/-M30@@-D) (See page 27) 13 W max. (CP1L-L20/-L14/-L10@@-D) Inrush current * 100 to 120 VAC inputs: 20 A max. (for cold start at room temperature) 8 ms max. 200 to 240 VAC inputs: 40 A max. (for cold start at room temperature), 8 ms max. 30 A max. (for cold start at room temperature) 20 ms max. External power supply 300 mA at 24 VDC (CP1L-M60/-M40/-M30@@-A) 200 mA at 24 VDC (CP1L-L20/-L14/-L10@@-A) None Insulation resistance 20 MΩ min. (at 500 VDC) between the external AC terminals and GR terminals No insulation between primary and secondary for DC power supply Dielectric strength 2,300 VAC at 50/60 Hz for 1 min between the external AC and GR terminals, leakage current: 5 mA max. No insulation between primary and secondary for DC power supply Noise immunity Conforms to IEC 61000-4-4. 2 kV (power supply line) Vibration resistance Conforms to JIS C0040. 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes each. Sweep time: 8 minutes × 10 sweeps = total time of 80 minutes) Shock resistance Conforms to JIS C0041. 147 m/s2 three times each in X, Y, and Z directions Ambient operating temperature 0 to 55°C Ambient humidity 10% to 90% (with no condensation) Ambient operating environment No corrosive gas Ambient storage temperature −20 to 75°C (Excluding battery.) Power holding time 10 ms min. 2 ms min. * The above values are for a cold start at room temperature for an AC power supply, and for a cold start for a DC power supply. • A thermistor (with low-temperature current suppression characteristics) is used in the inrush current control circuitry for the AC power supply. The thermistor will not be sufficiently cooled if the ambient temperature is high or if a hot start is performed when the power supply has been OFF for only a short time. In those cases the inrush current values may be higher (as much as two times higher) than those shown above. Always allow for this when selecting fuses and breakers for external circuits. • A capacitor charge-type delay circuit is used in the inrush current control circuitry for the DC power supply. The capacitor will not be charged if a hot start is performed when the power supply has been OFF for only a short time, so in those cases the inrush current values may be higher (as much as two times higher) than those shown above. 6 CP1L Performance Specifications ● CP1L CPU Unit (EM/EL Type) Type Item CP1L-EM40 (40 points) CP1L-EM30 (30 points) CP1L-EL20 (20 points) CP1L-EM40D@-@ CP1L-EM30D@-@ CP1L-EL20D@-@ Models Control method Stored program method I/O control method Cyclic scan with immediate refreshing Program language Ladder diagram Function blocks Maximum number of function block definitions: 128 Maximum number of instances: 256 Languages usable in function block definitions: Ladder diagrams, structured text (ST) Instruction length 1 to 7 steps per instruction Instructions Approx. 500 (function codes: 3 digits) Instruction execution time Basic instructions: 0.55 μs min. Special instructions: 4.1 μs min. Common processing time 0.4ms Program capacity 10K steps FB program memory Number of tasks 288 (32 cyclic tasks and 256 interrupt tasks) Scheduled interrupt tasks Input interrupt tasks 1 (interrupt task No. 2, fixed) 6 (interrupt task No. 140 to 145, fixed) (Interrupt tasks can also be specified and executed for high-speed counter interrupts and executed.) Maximum subroutine number 256 Maximum jump number 256 I/O areas 5K steps 10K steps Input bits 24: CIO 0.00 to CIO 0.11 and CIO 1.00 to CIO 1.11 18: CIO 0.00 to CIO 0.11 and CIO 1.00 to CIO 1.05 12: CIO 0.00 to CIO 0.11 Output bits 8: CIO 100.00 to CIO 100.07 and CIO 101.00 to CIO 101.07 12: CIO 100.00 to CIO 100.07 and CIO 101.00 to CIO 101.03 8: CIO 100.00 to CIO 100.07 1:1 Link Area 1,024 bits (64 words): CIO 3000.00 to CIO 3063.15 (CIO 3000 to CIO 3063) Serial PLC Link Area 1,440 bits (90 words): CIO 3100.00 to CIO 3189.15 (CIO 3100 to CIO 3189) Work bits 8,192 bits (512 words): W000.00 to W511.15 (W0 to W511) CIO Area: 37,504 bits (2,344 words): CIO 3800.00 to CIO 6143.15 (CIO 3800 to CIO 6143) TR Area 16 bits: TR0 to TR15 Holding Area 8,192 bits (512 words): H0.00 to H511.15 (H0 to H511) AR Area Read-only (Write-prohibited): 7168 bits (448 words): A0.00 to A447.15 (A0 to A447) Read/Write: 8192 bits (512 words): A448.00 to A959.15 (A448 to A959) Timers 4,096 bits: T0 to T4095 Counters 4,096 bits: C0 to C4095 DM Area 32 Kwords: D0 to D32767 Data Register Area 16 registers (16 bits): DR0 to DR15 Index Register Area 16 registers (32 bits): IR0 to IR15 Task Flag Area 32 flags (32 bits): TK0000 to TK0031 Trace Memory 4,000 words (500 samples for the trace data maximum of 31 bits and 6 words.) Memory Cassette * A special Memory Cassette (CP1W-ME05M) can be mounted. Clock function Supported. Accuracy (monthly deviation): -4.5 min to -0.5 min (ambient temperature: 55°C), -2.0 min to +2.0 min (ambient temperature: 25°C), -2.5 min to +1.5 min (ambient temperature: 0°C) 10 Kwords: D0 to D9999, D32000 to D32767 Built-in Ethernet Port (Connecting Support Software, Message Communications, Socket Service) Communications functions A maximum of two Serial Communications Option Boards can be mounted. A maximum of one Serial Communications Option Board can be mounted. Memory backup Flash memory: User programs, parameters (such as the PLC Setup), comment data, and the entire DM Area can be saved to flash memory as initial values. Battery backup: The Holding Area, DM Area, and counter values (flags, PV) are backed up by a battery. Battery service life 5 years at 25°C. (Use the replacement battery within two years of manufacture.) Built-in input terminals 40 (24 inputs, 16 outputs) 30 (18 inputs, 12 outputs) 20 (12 inputs, 8 outputs) Number of connectable Expansion Units and Expansion I/O Units CP-series Expansion Unit and Expansion I/O Units: 3 max. CP-series Expansion Units and Expansion I/O Units: 1 max. Max. number of I/O points 160 (40 built in + 40 per Expansion (I/O) Unit x 3 Units) 60 (20 built in + 40 per Expansion (I/O) Unit x 1 Unit) Interrupt inputs 6 inputs (Response time: 0.3 ms) Interrupt inputs counter mode 6 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down counters Quick-response inputs 6 points (Min. input pulse width: 50 μs max.) Scheduled interrupts 1 High-speed counters 4 counters, 2 axes (24-VDC input) 4 inputs: Differential phases (4x), 50 kHz Single-phase (pulse plus direction, up/down, increment), 100 kHz Value range: 32 bits, Linear mode or ring mode Interrupts: Target value comparison or range comparison Pulse outputs (models with transistor outputs only) 150 (30 built in + 40 per Expansion (I/O) Unit x 3 Units) Pulse outputs Trapezoidal or S-curve acceleration and deceleration (Duty ratio: 50% fixed) 2 outputs, 1 Hz to 100 kHz (CCW/CW or pulse plus direction) PWM outputs Duty ratio: 0.0% to 100.0% (specified in increments of 0.1% or 1%) 2 outputs, 0.1 to 6553.5 Hz or 1 to 32,800 Hz (Accuracy: +1%/0% at 0.1 Hz to 10,000 Hz and +5%/0% at 10,000 Hz to 32,800 Hz) External analog input 2 input (Resolution: 1/1000, Input range: 0 to 10 V). Not isolated. * Can be used for program backups and auto-booting. 7 CP1L ● CP1L CPU Unit (M/L Type) CP1L-M60 (60 points) CP1L-M40 (40 points) CP1L-M30 (30 points) CP1L-L20 (20 points) CP1L-L14 (14 points) CP1L-L10 (10 points) CP1L-M60@@-@ CP1L-M40@@-@ CP1L-M30@@-@ CP1L-L20@@-@ CP1L-L14@@-@ CP1L-L10@@-@ Type Item Models Control method Stored program method I/O control method Cyclic scan with immediate refreshing Program language Ladder diagram Function blocks Maximum number of function block definitions: 128 Maximum number of instances: 256 Languages usable in function block definitions: Ladder diagrams, structured text (ST) Instruction length 1 to 7 steps per instruction Instructions Approx. 500 (function codes: 3 digits) Instruction execution time Basic instructions: 0.55 μs min. Special instructions: 4.1 μs min. Common processing time 0.4 ms Program capacity 10K steps Number of tasks 288 (32 cyclic tasks and 256 interrupt tasks) Scheduled interrupt tasks Input interrupt tasks 5K steps 1 (interrupt task No. 2, fixed) 4 (interrupt task No. 2 (interrupt task No. 140 to 143, fixed) 140 to 141, fixed) 6 (interrupt task No. 140 to 145, fixed) (Interrupt tasks can also be specified and executed for high-speed counter interrupts and executed.) Maximum subroutine number 256 Maximum jump number I/O areas 256 Input bits 36: CIO 0.00 to CIO 24: CIO 0.00 to CIO 18: CIO 0.00 to CIO 12: CIO 0.00 to CIO 8: CIO 0.00 to CIO 0.11, CIO 1.00 to 0.11 and CIO 1.00 0.11 and CIO 1.00 0.11 0.07 CIO 1.11, and CIO to CIO 1.05 to CIO 1.11 2.00 to CIO 2.11 6: CIO 0.00 to CIO 0.05 Output bits 24: CIO 100.00 to CIO 100.07, CIO 101.00 to CIO 101.07, and CIO 102.00 to CIO 102.07 4: CIO 100.00 to CIO 100.03 1:1 Link Area 1,024 bits (64 words): CIO 3000.00 to CIO 3063.15 (CIO 3000 to CIO 3063) Serial PLC Link Area 12: CIO 100.00 to 24: CIO 0.00 to CIO CIO 100.07 and 0.11 and CIO 1.00 CIO 101.00 to CIO to CIO 1.11 101.03 8: CIO 100.00 to CIO 100.07 6: CIO 100.00 to CIO 100.05 1,440 bits (90 words): CIO 3100.00 to CIO 3189.15 (CIO 3100 to CIO 3189) Work bits 8,192 bits (512 words): W000.00 to W511.15 (W0 to W511) CIO Area: 37,504 bits (2,344 words): CIO 3800.00 to CIO 6143.15 (CIO 3800 to CIO 6143) TR Area 16 bits: TR0 to TR15 Holding Area 8,192 bits (512 words): H0.00 to H511.15 (H0 to H511) AR Area Read-only (Write-prohibited): 7168 bits (448 words): A0.00 to A447.15 (A0 to A447) Read/Write: 8192 bits (512 words): A448.00 to A959.15 (A448 to A959) Timers 4,096 bits: T0 to T4095 Counters 4,096 bits: C0 to C4095 DM Area 32 Kwords: D0 to D32767 Data Register Area 16 registers (16 bits): DR0 to DR15 Index Register Area 16 registers (32 bits): IR0 to IR15 Task Flag Area 32 flags (32 bits): TK0000 to TK0031 Trace Memory 4,000 words (500 samples for the trace data maximum of 31 bits and 6 words.) Memory Cassette A special Memory Cassette (CP1W-ME05M) can be mounted. Note: Can be used for program backups and auto-booting. Clock function Supported. Accuracy (monthly deviation): −4.5 min to −0.5 min (ambient temperature: 55°C), −2.0 min to +2.0 min (ambient temperature: 25°C), −2.5 min to +1.5 min (ambient temperature: 0°C) 10 Kwords: D0 to D9999, D32000 to D32767 One built-in peripheral port (USB 1.1): For connecting Support Software only. Communications functions 8 A maximum of two Serial Communications Option Boards can be A maximum of one Serial Communications Not supported. mounted. Option Board can be mounted. A maximum of two Ethernet Option Board can be mounted. When using CP1W-CIF41 Ver.1.0, one Ethernet Option Board can be mounted. A maximum of one Ethernet Option Board Not supported. can be mounted. Memory backup Flash memory: User programs, parameters (such as the PLC Setup), comment data, and the entire DM Area can be saved to flash memory as initial values. Battery backup: The Holding Area, DM Area, and counter values (flags, PV) are backed up by a battery. Battery service life 5 years at 25°C. (Use the replacement battery within two years of manufacture.) Built-in input terminals 60 (36 inputs, 24 outputs) Number of connectable Expansion Units and Expansion I/O Units CP-series Expansion Unit and Expansion I/O Units: 3 max. Max. number of I/O points 180 (60 built in + 40 160 (40 built in + 40 150 (30 built in + 40 60 (20 built in + 40 per Expansion (I/O) per Expansion (I/O) per Expansion (I/O) per Expansion (I/O) Unit × 1 Unit) Unit × 3 Units) Unit × 3 Units) Unit × 3 Units) 54 (14 built in + 40 per Expansion (I/O) Unit × 1 Unit) 10 (10 built in) Interrupt inputs 6 inputs (Response time: 0.3 ms) 4 inputs (Response time: 0.3 ms) 2 inputs (Response time: 0.3 ms) 40 (24 inputs, 16 outputs) 30 (184 inputs, 12 outputs) 20 (12 inputs, 8 outputs) 14 (8 inputs, 6 outputs) 10 (6 inputs, 4 outputs) CP-series Expansion Units and Expansion Not supported. I/O Units: 1 max. CP1L Type Item Models CP1L-M60 (60 points) CP1L-M40 (40 points) CP1L-M30 (30 points) CP1L-L20 (20 points) CP1L-M60@@-@ CP1L-M40@@-@ CP1L-M30@@-@ CP1L-L20@@-@ CP1L-L14 (14 points) CP1L-L14@@-@ CP1L-L10@@-@ 2 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down counters 2 points (Min. input pulse width: 50 μs max.) Interrupt inputs counter mode 6 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down counters 4 inputs (Response frequency: 5 kHz max. for all interrupt inputs), 16 bits Up or down counters Quick-response inputs 6 points (Min. input pulse width: 50 μs max.) 4 points (Min. input pulse width: 50 μs max.) Scheduled interrupts 1 High-speed counters 4 counters, 2 axes (24-VDC input) 4 inputs: Differential phases (4x), 50 kHz Single-phase (pulse plus direction, up/down, increment), 100 kHz Value range: 32 bits, Linear mode or ring mode Interrupts: Target value comparison or range comparison Pulse outputs (models with transistor outputs only) CP1L-L10 (10 points) Pulse outputs Trapezoidal or S-curve acceleration and deceleration (Duty ratio: 50% fixed) 2 outputs, 1 Hz to 100 kHz (CCW/CW or pulse plus direction) PWM outputs Duty ratio: 0.0% to 100.0% (specified in increments of 0.1% or 1%) 2 outputs, 0.1 to 6553.5 Hz or 1 to 32,800 Hz (Accuracy: +1%/0% at 0.1 Hz to 10,000 Hz and +5%/0% at 10,000 Hz to 32,800 Hz) Analog control 1 (Setting range: 0 to 255) External analog input 1 input (Resolution: 1/256, Input range: 0 to 10 V). Not isolated. 9 CP1L Built-in Inputs ■ Input Terminal Block Arrangement (Top Block) ● CP1L (20 Inputs) ● CP1L (60 Inputs) · AC Power Supply Models L1 L2/N COM 01 00 · AC Power Supply Models 03 02 05 04 07 06 09 08 11 10 00 − NC COM 01 00 03 02 03 02 05 04 07 06 09 08 11 10 05 04 07 06 09 08 11 10 Inputs (CIO 0) 01 00 03 02 01 00 Inputs (CIO 1) Inputs (CIO 0) · DC Power Supply Models + 01 03 02 05 04 07 06 09 08 11 L1 L2/N COM 10 00 Inputs (CIO 2) 05 04 07 06 09 08 11 10 01 00 03 02 07 06 09 08 11 10 02 05 04 07 06 09 08 11 10 · DC Power Supply Models + − COM NC Inputs (CIO 2) Inputs (CIO 1) 03 Inputs (CIO 0) 05 04 01 01 00 03 02 05 04 07 06 09 08 11 10 Inputs (CIO 0) ● CP1L (14 Inputs) ● CP1L (40 Inputs) · AC Power Supply Models L1 L2/N COM 01 00 · AC Power Supply Models 03 02 05 04 07 06 09 08 11 10 Inputs (CIO 0) 01 00 03 02 05 04 07 06 09 08 11 − NC COM 01 00 L2/N COM 01 00 Inputs (CIO 1) 03 02 05 04 07 06 09 08 11 10 01 00 03 02 05 04 07 06 09 08 11 10 + − COM NC Inputs (CIO 1) 01 00 · AC Power Supply Models L1 L2/N COM 01 03 05 07 09 11 01 03 02 04 06 08 10 Inputs (CIO 0) 00 02 04 NC − NC COM 00 01 02 05 04 07 06 09 08 11 10 01 00 03 02 Inputs (CIO 1) 05 04 Inputs (CIO 0) COM 01 03 Inputs (CIO 0) 10 02 · DC Power Supply Models Inputs (CIO 1) · DC Power Supply Models + 03 05 00 00 07 06 05 04 Inputs (CIO 0) · AC Power Supply Models 01 03 02 ● CP1L (10 Inputs) ● CP1L (30 inputs) L2/N COM 05 04 NC NC NC NC · DC Power Supply Models Inputs (CIO 0) L1 03 02 Inputs (CIO 0) · DC Power Supply Models + L1 10 NC 05 04 NC 00 03 02 05 04 Inputs (CIO 0) 07 06 NC NC NC NC CP1L ■ Built-in Input Area Input terminal block Number of inputs Word Input operation High-speed counter operation Origin search Origin searches enabled for pulse outputs 0 and 1 Bit Normal inputs 00 Normal input 0 --- --- High-speed counter 0 (increment) High-speed counter 0 (phase-A, increment, or count input) --- --- --- 01 Normal input 1 --- --- High-speed counter 1 (increment) High-speed counter 0 (phase-B, decrement, or count input) --- --- --- --- High-speed counter 2 (increment) High-speed counter 1 (phase-A, increment, or count input) --- Pulse output 0: Origin proximity input signal --- Pulse output 0: Origin proximity input signal 02 Normal input 2 Interrupt Quick-response inputs inputs Operation settings • High-speed counters enabled • Phase-Z signal reset --- Two-phase Single-phase CPU Units CPU Units CPU Units (differential phase x4, (increment pulse with 20 to with 14 with 10 up/down, or pulse input) 60 points points points plus direction) 10 CIO 0 03 Normal input 3 --- --- High-speed counter 3 (increment) High-speed counter 1 (phase-B, decrement, or count input) --- Pulse output 1: Origin proximity input signal 04 Normal input 4 Interrupt input 0 Quick-response input 0 Counter 0, phaseZ/reset input High-speed counter 0 (phase-Z/reset) --- --- --- --- Pulse output 0: Origin input signal- 05 Normal input 5 Interrupt input 1 Quick-response input 1 Counter 1, phaseZ/reset input 06 Normal input 6 Interrupt input 2 Quick-response input 2 Counter 2, phaseZ/reset input Pulse output 0: Origin input signal --- 07 Normal input 7 Interrupt input 3 Quick-response input 3 Counter 3, phaseZ/reset input Pulse output 1: Origin input signal --- 08 Normal input 8 Interrupt input 4 Quick-response input 4 --- --- --- --- 09 Normal input 9 Interrupt input 5 Quick-response input 5 --- --- --- --- --- Pulse output 0: Origin proximity input signal --- --- --- --- 14 10 20 30 60 CIO 2 --- --- --- 11 Normal input 11 --- --- --- Pulse output 1: Origin proximity input signal 00 Normal input 12 --- --- --- --- --- --- to to to to to to to to to 05 Normal input 17 --- --- --- --- --- --- --- 06 Normal input 18 --- --- --- --- --- --- --- to to to to to to to to to 11 Normal input 23 --- --- --- --- --- --- --- 00 Normal input 24 --- --- --- --- --- --- --- to to to to to to to to to 11 Normal input 35 --- --- --- --- --- --- --- CIO 1 40 Normal input 10 High-speed counter 1 (phase-Z/reset) 11 CP1L Built-in Outputs ■ Output Terminal Block Arrangement (Bottom Block) ● CP1L (60 Outputs) ● CP1L (20 Outputs) · AC Power Supply Models + - 00 01 02 · AC Power Supply Models 04 05 07 00 02 04 05 07 00 02 COM COM COM 03 COM 06 COM 01 03 COM 06 COM 01 CIO 101 CIO 102 CIO 100 · DC Power Supply Models NC 00 01 02 04 05 07 03 COM 06 + − 05 07 CIO 100 00 02 04 05 07 00 02 03 COM 06 COM 01 04 05 07 01 02 NC NC 03 04 06 05 00 07 CIO 100 01 03 COM 02 04 COM 01 02 01 04 03 02 05 COM 04 03 COM(V-) 07 06 05 COM 07 06 CIO 100 03 CP1L-EL20DT1-D 04 06 00 01 03 04 06 V+ NC 00 V- CP1L-EM40DR-D/CP1L-M40D@-D 02 00 COM COM COM V+ 07 CIO 101 01 07 06 CP1L-EL20DT-D 05 05 · DC Power Supply Models 00 05 COM CIO 100 COM COM COM COM NC 04 03 03 COM 06 · AC Power Supply Models 00 02 · DC Power Supply Models CP1L-EL20DR-D/CP1L-L20D@-D CIO 102 CIO 101 ● CP1L (40 Outputs) - 01 CIO 100 04 NC COM COM COM 03 COM 06 COM 01 + 00 COM COM COM COM COM COM COM 05 07 CIO 100 COM 02 COM 05 00 01 02 04 05 07 07 V- CIO 101 03 COM(V+) COM 06 CIO 100 CP1L-EM40DT-D V+ 00 V- 01 02 03 COM(V-) 04 COM 06 05 00 07 CIO 100 01 03 COM 02 04 COM ● CP1L (14 Outputs) 06 05 07 + CIO 101 − CP1L-EM40DT1-D V+ 00 · AC Power Supply Models 01 02 03 04 06 00 01 03 04 00 01 02 COM COM COM 04 03 05 COM NC NC CIO 100 06 · DC Power Supply Models V- COM(V+) COM 05 07 CIO 100 COM 02 COM 05 07 NC CIO 101 ● CP1L (30 Outputs) NC 00 01 02 COM COM COM 04 03 CIO 100 · AC Power Supply Models + 00 01 02 04 05 07 00 ● CP1L (10 Outputs) 02 · AC Power Supply Models COM COM COM 03 COM 06 CIO 100 COM 01 03 CIO 101 · DC Power Supply Models CP1L-EM30DR-D/CP1L-M30D@-D NC NC 00 01 02 COM COM COM 04 03 00 05 COM 07 06 00 COM 02 01 NC 03 01 02 04 03 05 COM 07 06 00 COM 02 01 03 CIO 101 CIO 100 CP1L-EM30DT1-D V+ V- 00 CIO 100 12 01 COM(V+) 02 04 03 05 COM 07 06 00 COM CIO 101 00 02 01 03 01 02 NC COM COM COM 03 CIO 100 CIO 101 COM(V-) 02 CIO 100 CIO 100 V+ 01 · DC Power Supply Models CP1L-EM30DT-D V- 00 COM COM COM 03 05 COM NC NC CP1L ■ Built-in Output Area Output Terminal Block When the instructions to the right are not executed When a pulse output instruction (SPED, ACC, PLS2, or ORG) is executed Number of outputs 10 CIO 100 Bit Normal output 00 Normal output 0 01 Normal output 1 02 Normal output 2 CW/CCW Pulse plus direction Pulse output 0 (CW) Pulse output 0 (pulse) Pulse output 0 (CCW) Pulse output 0 (direction) Pulse output 1 (CW) Pulse output 1 (pulse) Pulse output 1 (CCW) Pulse output 1 (direction) 30 CIO 101 40 CIO 102 CPU Units with 10 point PWM output --- --- --- --- --- PWM output 0 --- --- --- --- Origin search 0 (Error counter reset output) PWM output 1 03 Normal output 3 04 Normal output 4 --- --- Origin search 0 (Error counter reset output) --- --- 05 Normal output 5 --- --- Origin search 1 (Error counter reset output) --- --- 06 Normal output 6 --- --- --- --- --- 07 Normal output 7 --- --- --- --- --- 00 Normal output 8 --- --- --- --- --- to to to to to to 03 Normal output 11 --- --- --- 04 Normal output 12 --- --- --- to to to to to to to 07 Normal output 15 --- --- --- --- --- 01 Normal output 16 --- --- --- --- --- to to to to to to to 07 Normal output 23 --- --- --- --- --- 14 20 When the origin search function is used CPU Units with 14 to 60 points When the PWM instruction is executed Variable duty ratio pulse output Fixed duty ratio pulse output Word 60 When the origin search function is set to be used in the PLC Setup, and an origin search is executed by the ORG instruction to ----- 13 CP1L I/O Specifications for CPU Units ■ Input Specifications Specifications Interrupt inputs and quick-response inputs Normal inputs CIO 0.00 to CIO 0.03 CIO 0.04 to CIO 0.09 CIO 0.10, CIO 0.11, CIO 1.00 to CIO 1.11, and CIO 2.00 to 2.11 Input voltage 24 VDC +10%/–15% Applicable sensors 2-wire sensors or 3-wire sensors Input impedance 3.0 kΩ 4.7 kΩ Input current 7.5 mA typical 5 mA typical ON voltage 17.0 VDC min. 14.4 VDC min. OFF voltage/current 1 mA max. at 5.0 VDC ON delay 2.5 μs max. 50 μs max. 1 ms max. OFF delay 2.5 μs max. 50 μs max. 1 ms max. IN IN Input LED 3.0 kΩ Internal circuits IN COM 3.0 kΩ 910 Ω IN Input LED 1000 pF 4.3 kΩ 1000 pF Circuit configuration IN Input LED Internal circuits IN COM 4.7 kΩ 750 Ω ITEM High-speed counter inputs (phases A and B) Internal circuits COM ● High-speed Counter Function Input Specifications Input bits: CIO 0.00 to CIO 0.03 Item Specifications • Differential phase input mode • Pulse plus direction input mode • Increment mode • Up/down input mode 20.0 μs min. ON Phase A 10.0 μs min. ON/OFF delay 90% 50% 10% OFF ON ON Phase A 90% 50% 10% OFF 90% 50% 10% OFF T1 2.5 μs min. 2.5 μs min. T2 T3 T4 T1,T2,T3,T4 : 2.5 μs min ● Interrupt Input Counter Mode Input bits: CIO 0.04 to CIO 0.09 Item Specifications ON ON/OFF delay 90% 10% OFF 50 μs min. 50 μs min. ■ Output Specifications ● CPU Units with Relay Outputs Specifications Min. switching capacity 5 VDC, 10 mA Electrical 500 Resis100,000 operations (24 VDC) tive load 200 30 VDC/250 VAC resistive load Induc48,000 operations (250 VAC, cosφ = 0.4) tive load Mechanical 100 30 VDC τ = 7 ms 20,000,000 operations ON delay 15 ms max. OFF delay 15 ms max. Output LED 50 30 20 10 5 125 VAC cos φ = 0.4 3 2 250 VAC cos φ = 0.4 OUT L 0.1 Circuit configuration Internal circuits 0.2 0.3 0.5 0.7 1 2 3 5 10 Contact current (A) L OUT COM 14 125 VAC resistive load 300 Life (x 104) Service life of relay Note: Under the worst conditions, the service life of output contacts is as shown on the left. The service life of relays is as shown in the following diagram as a guideline. Maximum 250 VAC: 2 A, 24 VDC: 2 A Common terminal current (A) Item Max. switching capacity 2 A, 250 VAC (cosφ = 1), 2 A, 24 VDC 4 A/common) 4 3 0 47 55 Ambient temperature (˚C) CP1L ● CPU Units with Transistor Outputs (Sinking/Sourcing) Specifications Item CIO 100.00 to CIO 100.03 Max. switching capacity 4.5 to 30 VDC: 300 mA/point, 0.9 A/common, 3.6 A/Unit (See notes 3 and 4.) Min. switching capacity 4.5 to 30 VDC, 1 mA Leakage current 0.1 mA max. Residual voltage 0.6 V max. ON delay 0.1 ms max. OFF delay 0.1 ms max. Fuse 1/common (See note 2.) CP1L-EL/EM CPU Unit Circuit configuration CIO 100.04 to CIO 101.07 CIO 102.00 to CIO 102.11 --- 1.5 V max. 1 ms max. Sinking Outputs Sinking Outputs Sourcing Outputs Sourcing Outputs Sinking Outputs Sinking Outputs OUT OUT Internal circuits OUT L OUT L Internal circuits Internal circuits 4.5 to 30 VDC L 4.5 to 30 VDC COM (−) CP1L-L/M CPU Unit L COM (−) Sourcing Outputs Sourcing Outputs COM (+) COM (+) Internal circuits Internal circuits OUT OUT Note: 1. 2. 3. 4. Internal circuits 4.5 to 30 VDC 4.5 to 30 VDC L OUT L OUT Do not apply a voltage or connect a load to an output terminal exceeding the maximum switching capacity. Fuses cannot be replaced by the user. Also do not exceed 0.9 A for the total for CIO 100.00 to CIO 100.03. (CIO 100.00 to CIO 100.03 is different common.) A maximum of 0.9 A per common can be switched at an ambient temperature of 50°C. L L 0.9 Common terminal 0.6 current (A) 0 50 55 Ambient temperature (˚C) ● Pulse outputs ● Pulse outputs Output bits CIO 100.00 to CIO 100.03 Item Output bits CIO100.01, CIO 100.03 Specifications Item Specifications Max. switching capacity 30 mA at 4.75 to 26.4 VDC Max. switching capacity 30 mA at 4.75 to 26.4 VDC Min. switching capacity 7 mA at 4.75 to 26.4 VDC Max. output frequency CP1L: 32.8 kHz Max. output frequency 100 kHz PWM output precision ON duty +5%, −0% at output frequency of 1 kHz OFF OFF 90% Output waveform ON ON 10% ton Output waveform T 4 ms min. 2 ms min. Note: 1. The above values assume a resistive load and do not consider the impedance of the cable connecting the load. 2. The pulse widths during actual use may be smaller than the ones shown above due to pulse distortion caused by connecting cable impedance. 3. The OFF and ON refer to the output transistor. The output transistor is ON at level “L”. ON duty = ton × 100% T Note: 1. The above values assume a resistive load and do not consider the impedance of the cable connecting the load. 2. The pulse widths during actual use may be smaller than the ones shown above due to pulse distortion caused by connecting cable impedance. 3. The OFF and ON refer to the output transistor. The output transistor is ON at level “L”. 15 CP1L ■ Analog Input Specifications Item Specifications Number of analog inputs 1 *1 2 *2 Input signal range 0 to 10V Max. rated input 0 to 15V External input impedance 100KΩ min. Resolution 1/256 *1 1/1000 (full scale) *2 Overall accuracy 0 to 55°C ±3% (full scale) A/D conversion data Full scale for 0000 to 1023 (03FF) Hex Isolation method - *1. CP1L-EL CPU Unit or CP1L-EM CPU Unit only. *2. CP1L-L CPU Unit or CP1L-M CPU Unit only. ■ Built-in Ethernet Specifications (CP1H-EL CPU Units or CP1H-EM CPU Unit Only) Item Specifications Protocol used TCP/IP, UDP, ARP, ICMP (ping only), BOOTP Applications FINS, Socket, SNTP, DNS (client) Media access method CSMA/CD Modulation method Baseband Transmission paths Star form Baud rate 100 Mbit/s (100Base-TX), 10 Mbit/s (10Base-T) 100 Mbit/s • Unshielded twisted-pair (UDP) cable Categories: 5, 5e • Shielded twisted-pair (STP) cable Categories: 100 Ω at 5, 5e 10 Mbit/s • Unshielded twisted-pair (UDP) cable Categories: 3, 4, 5, 5e • Shielded twisted-pair (STP) cable Categories: 100 Ω at 3, 4, 5, 5e Transmission media Transmission Distance 100 m (distance between hub and node) Item FINS Communications Service Specifications Number of nodes 254 Message length 1016 bytes max. Size of buffer 8k Communications Function FINS/UDP method FINS/TCP method FINS Communications Service (UDP/IP, TCP/IP) Protocol used UDP/IP Port number 9600 (default) Can be changed. Protection No Protocol used TCP/IP Number of connections Up to 2 simultaneous connections and only one connection can be set to client Port number 9600 (default) Can be changed. Protection Yes (Specification of client IP addresses when unit is used as a server) *1. CX-One version 4.3 or higher is required. *2. To connect the CP1L CPUs with the NS-series Programmable Terminals via Ethernet, make sure that the system version of NS Series is 8.2 or higher. 16 CP1L External Interfaces ■ CP1L CPU Unit Nomenclature ● CP1L CPU Units (EL Type) with 20 Points Terminal Block (Fixed) Option Board slot Ethernet port Terminal Block (Fixed) ● CP1L CPU Units (EM Type) with 40 or 30 Points ● Option Board slots 1 (left) and 2 (right) Front Terminal Block (Removable) Battery DIP switch Memory Cassette slot External analog settings input connector Ethernet port Expansion I/O Unit connector Terminal Block (Removable) ● CP1L CPU Units (M Type) with 40 Points ● Option Board Slot 1 Front Option Board Slot 2 Terminal Block (Removable) Battery Peripheral USB Port IN L1 L2/N COM 01 00 03 02 05 04 07 06 09 08 11 10 01 00 03 05 02 04 00 01 COM 07 06 09 08 11 10 Analog Control 2 3 4 5 6 External analog settings input connector A{ 00 A| 01 COM 02 COM 03 COM 04 COM 06 05 07 03 02 04 COM 06 05 07 DIP switch OUT Memory Cassette Slot Terminal Block (Removable) Expansion Unit and Expansion I/O Unit Connector 17 CP1L ● CP1L CPU Units (L Type) with 20 or 14 Points ● CP1L CPU Units (L Type) with 10 Points Terminal Block (Fixed) Terminal Block (Fixed) IN L1 Option Board Slot L2/N COM 01 00 Memory Cassette Slot 03 02 05 04 07 06 09 08 11 10 SYSMAC CP1L Memory Cassette Slot PERIPHERAL BATTERY + - 00 COM 01 COM 02 COM 04 03 05 COM 07 06 OUT Battery Battery Terminal Block (Fixed) 18 Terminal Block (Fixed) CP1L Option Unit Specifications ■ Option Unit Specifications Yes : Supported, No : Not supported Item Applicable CPU Units Interface CP1L-EM Type CP1L-EL Type CP1L-M Type CP1L-L14/L20 CP1L-L10 Yes No No No No No Yes Yes Yes Serial Communications Option Boards (CP1W-CIF01/CIF11/CIF12) Yes Yes Yes Yes No Ethernet Option Boards (CP1W-CIF41) No No Yes Yes No Analog I/O Option Boards (CP1W-MAB21/ADB21/DAB21V) Yes Yes No No No LCD Option Boards (CP1W-DAM01) Yes Yes Yes Yes No Serial Communications Option Boards (CP1W-CIF01/CIF11/CIF12) Yes No Yes No No Ethernet Option Boards (CP1W-CIF41) No No Yes No No Analog I/O Option Boards (CP1W-MAB21/ADB21/DAB21V) Yes No No No No Ethernet port Connecting Support Software, Message Communications, and the other. Yes Peripheral USB port Bus for communications with various kinds of Support Software running on a personal computer. Serial port 1 * (Option board slot 1) Serial port 2 * (Option board slot 2) * You can choose one from among "Yes". ■ Serial Communications Option Boards (CP1W-CIF01/CIF11/CIF12) Product name Model Specifications RS-232C Option Board CP1W-CIF01 One RS-232C port Connector: D-Sub, 9 pin, female Maximum transmission distance: 15m One RS-232C connector (D-Sub, 9 pin, male) is included. (Plug: XM2A-0901, Hood: XM2S-0911-E) RS-422A/485 Option Board CP1W-CIF11 One RS-422A/485 port Terminal block: using ferrules Maximum transmission distance: 50m RS-422A/485 Isolated-type Option Board CP1W-CIF12 One RS-422A/485 port (Isolated) Terminal block: using ferrules Maximum transmission distance: 500m Serial communications mode * Host Link, 1:N NT Link, 1:1 NT Link, Noprotocol, Serial PLC Link Slave, Serial PLC Link Master, Serial Gateway converted to CompoWay/F, and Tool Bus, 1:1 Link Master, and 1:1 Link Slave. * Serial PLC Link can be used with either serial port 1 or serial port 2. 19 CP1L ■ Ethernet Communications Specifications (CP1W-CIF41) Item Specifications Applicable PLCs CP1L CPU Units Note: The Ethernet Option Board cannot be used for the CP1L-L10. Number of Units that can be mounted 2 sets. (The CP1W-CIF41 Ver.1.0 and Ver.2.0 can be combined and used with one CPU Unit. When using CP1W-CIF41 Ver.1.0, only one unit can be mounted in an option board slot.) Protocol used TCP/IP, UDP Applications FINS Media access method CSMA/CD Modulation method Baseband Transmission paths Star form Baud rate 100 Mbit/s (100Base-TX), 10 Mbit/s (10Base-T) Transfer 100 Mbit/s • Unshielded twisted-pair (UDP) cable Categories: 5, 5e • Shielded twisted-pair (STP) cable Categories: 100 Ω at 5, 5e 10 Mbit/s • Unshielded twisted-pair (UDP) cable Categories: 3, 4, 5, 5e • Shielded twisted-pair (STP) cable Categories: 100 Ω at 3, 4, 5, 5e Transmission media Transmission Distance 100 m (distance between hub and node) Item FINS Communications Service Specifications Number of nodes 254 Message length 1016 bytes max. Size of buffer 8k Communications Function FINS/UDP method FINS/TCP method FINS Communications Service (UDP/IP, TCP/IP) Protocol used UDP/IP Port number 9600 (default) Can be changed. Protection No Protocol used TCP/IP Number of connections Up to 2 simultaneous connections and only one connection can be set to client Port number 9600 (default) Can be changed. Protection Yes (Specification of client IP addresses when unit is used as a server) Note: 1. CX-Programmer version 8.1 or higher (CX-One version 3.1 or higher) is required. 2. Use CX-Integrator version 2.33 or higher (CX-One version 3.1 or higher) when the system needs to be set the routing tables. However, CX-Integrator does not support the other functions, using CP1W-CIF41, such as transferring the parameters and network structure. 3. To connect the CP1H/CP1L CPUs with the NS-series Programmable Terminals via Ethernet using CP1W-CIF41, make sure that the system version of NS Series is 8.2 or higher. Specifications Input Product name 20 Model Output Voltage Input 0V to 10V Current Input 0mA to 20mA Voltage Output 0V to 10V Resolution: 1/4000 Resolution: 1/2000 Resolution: 1/4000 Conversion time Current consumption 2CH - 2ms/point DC 5V 40mA max. CP1W-DAB21V - 2CH 2ms/point DC 5V 150mA max. CP1W-MAB221 2CH 2CH 6ms/4point DC 5V 150mA max. Analog Input Option Board CP1W-ADB21 Analog Output Option Board Analog I/O Option Board CP1L ■ LDC Option Board (CP1W-DAM01) ● Specifications Item Mounting port Communications protocol Weight Number of display characters Display characters Backlight Function CP1L: Option board slot 1 Note: The LCD Option Board cannot be used for the CP1L-L10. Peripheral bus (Turn ON DIP switch pin 4.) 30 g max. 4 rows × 12 characters: 48 characters max. 5 × 7 dots (alphanumeric, Japanese kana, and symbols). Display switchable between Japanese katakana and English. Electroluminescence (EL): Normal: Lit green; Error: Flashing red ● LCD Functions Operation Changing operating modes I/O memory PLC Setup operations Analog I/O monitor Error log display Memory cassette operation User monitor settings Description Change the PLC operating mode without using the CX-Programmer. Read and change the present values in the memory areas and force-set or force-reset bits. Read and change the PLC Setup. Monitor the analog adjustment and present value for the external analog setting input. Read the log of errors that have occurred. Transfer and verify user programs between the PLC and memory cassette. Read the status of up to 16 words and bits with comments. You can use this setting to read data on the startup display. Message display function settings Display a user-set message of up to 48 characters on the LCD Option Board when a specified bit turns ON. A maximum of 16 screens can be registered for display. Operation: Day timer Use this timer for ON/OFF switching at a specified times every day from the starting day of the week to the ending day of the week. Sixteen timers cam be set from timer 01 to timer 16. Starting day of the week Example: Monday Ending day of the week Example: Friday ON OFF Ending time Starting time Ending time Starting time Example: 9:00 Example: 17:00 9:00 17:00 Starting time 9:00 Ending time 17:00 Operation: Timers Weekly timer Use this timer for ON/OFF operation in intervals of one week that starts one day and ends another day. Sixteen timers cam be set from timer No. 01 to timer No. 16. Starting day of the week Example: Monday ON OFF Starting time Example: 12:00 Calendar timer Saving setting Language Other functions Use the calendar timers for ON or OFF operation in intervals of one year from the starting day to the ending day. Sixteen timers can be set from timer 01 to timer 16. Ending day of the week Example: Friday Ending time Starting time Example: 8:00 12:00 Ending time 8:00 Operation: ON OFF Starting day July 1 Ending day August 31 Set September 1 as the ending day. Save the various settings that you set with the LCD Option Board to the DM Area of the PLC. You can also write the settings saved in the PLC to the LCD Option Board. Changing the display language (Japanese/English) • Setting the time of the PLC's built-in clock • Reading system data (e.g., unit version and lot number) • Setting the backlight lighting time • Adjusting LCD contrast • Reading cycle time (e.g., average, maximum, and minimum) • Clearing data for the LCD Option Board 21 CP1L Expansion I/O Unit Specifications ■ CP1W-40EDR/40EDT/40EDT1/32ER/32ET/32ET1/20EDR1/20EDT/20EDT1/16ER/16ET/16ET1/8ED/8ER/8ET/8ET1 Expansion I/O Units Expansion I/O Units can be connected to the CPU Unit to configure the required number of I/O points. ● DC Inputs (CP1W-40EDR/40EDT/40EDT1/20EDR1/20EDT/20EDT1/8ED) Item Input voltage Input impedance Input current ON voltage OFF voltage ON delay OFF delay Specifications 24 VDC +10%/−15% 4.7 kΩ 5 mA typical 14.4 VDC min. 5.0 VDC max. 0 to 32 ms max. (Default: 8 ms) (See note 1.) 0 to 32 ms max. (Default: 8 ms) (See note 1.) IN IN 750 Ω Circuit configuration Input LED 4.7 kΩ Internal circuits COM Note: 1. Do not apply a voltage exceeding the rated voltage to an input terminal. 2. Can be set in the PLC Setup to 0, 0.5, 1, 2, 4, 8, 16 or 32 ms. The CP1W40EDR/EDT/EDT1 are fixed at 16 ms. ● Relay Outputs (CP1W-40EDR/32ER/20EDR1/16ER/8ER) Specifications 2 A, 250 VAC (cosφ = 1), 24 VDC 4 A/common 5 VDC, 10 mA Circuit configuration 500 150,000 operations (24 VDC) 100,000 operations (24 VAC cos = 0.4) Internal circuits 200 100 Output load current (%) 30 20 10 5 OUT L 3 2 L OUT 100 50 0 0.1 0.2 0.3 0.5 0.7 1 2 3 5 10 Contact current (A) COM 22 Relationship between Output Load Current and Ambient Temperature (CP1W-16ER/32ER) 120 VAC resistive load 24 VDC τ = 7 mA 120 VAC cos φ = 0.4 240 VAC cos φ = 0.4 24 VDC/240- VAC resistive load 300 50 20,000,000 operations 15 ms max. 15 ms max. Output LED Note: Under the worst conditions, the service life of output contacts is as shown on the left. The service life of relays is as shown in the following diagram as a guideline. Life (x104) Item Max. switching capacity Min. switching capacity Resistive Service Elec- load trical Inductive life of relay load Mechanical ON delay OFF delay Maximum 250 VAC: 2 A, 24 VDC: 2 A Switching frequency: 1,800 operations/h 55 43 Ambient temperature (˚C) When using the CP1W-32ER, do not allow more than 24 outputs to be ON simultaneously regardless of the ambient temperature. CP1L ● Transistor Outputs (Sinking/Sourcing) (CP1W-40EDT/-40EDT1/-32ET/-32ET1/-20EDT/-20EDT1/-16ET/-16ET1/-8ET/-8ET1) Item CP1W-40EDT CP1W-32E CP1W-40EDT1 CP1W-32ET1 24 VAC +10%/ −5%: 0.3 A/point 4.5 to 30 VDC: 0.3 A/point 0.9 A/common 3.6 A/common 0. 1mA max. 1.5 V max. 0.1ms max. 1 ms max. at 24 VDC +10%/−5%, 5 to 300 mA 0.9 A/common 1.8 A/common 0.9 A/common 3.6 A/common 16 pts (100%) 8 pts (100%) Max. switching ca- 4.5 to 30 VDC: 0.3 A/point pacity (See note 3.) Leakage current Residual voltage ON delay OFF delay Max. number of Simultaneosly ON Points of Output Fuse (See note 2.) Specifications CP1W-20EDT CP1W-16ET CP1W-20EDT1 CP1W-16ET1 24 pts (75%) 16 pts (100%) 8 pts (100%) Note: 1. Do not apply a voltage or connect a load to an output terminal exceeding the maximum switching capacity. 2. The fuses cannot be replaced by the user. 3. A maximum of 0.9 A per common can be switched at an ambient temperature of 50°C. 1/common Sinking Outputs Output LED Output LED OUT L Internal circuits 0.9 0.8 Sourcing Outputs L Circuit configuration CP1W-8ET CP1W-8ET1 • OUT00/01 4.5 to 30 VDC, 0.2 A/output • OUT02 to 07 4.5 to 30 VDC, 0.3 A/output 0.9 A/common 1.8 A/common OUT COM (−) COM (+) 24 VDC/ 4.5 to 30 VDC Internal circuits OUT L L OUT Common terminal current (A) 24 VDC/ 4.5 to 30 VDC 0 50 55 Ambient temperature (°C) 23 CP1L ■ CP1W-AD041/DA041/DA021/MAD11 Analog Units Analog values that are input are converted to binary data and stored in the input area, or binary data is output as analog values. ■ Analog Input Unit: CP1W-AD041 Model ■ Analog Output Unit: CP1W-DA041/DA021 CP1W-AD041 Item Input voltage Number of inputs 4 Input signal range 0 to 5 V, 1 to 5 V, 0 to 10 V, −10 to 10 V 0 to 20 mA 4 to 20 mA Max. rated input ±15 V ±30 mA External input impedance 1 MΩ min. Resolution 6000 25°C ±0.3% of full scale Overall accuracy 0 to 55°C ±0.6% of full scale Conversion time Model Input current CP1W-DA041/DA021 Item Input voltage Input current Number of outputs DA041: 4, DA021: 2 Output signal range 0 to 5 V, 0 to 10 V, or −10 to 10 V 0 to 20 mA or 4 to 20 mA Approx. 250 Ω Allowable external output load resistance 2 kΩ min. 350 Ω max. ±0.4% of full scale External output impedance 0.5 Ω max. --- Resolution 6000 ±0.8% of full scale 2.0 ms/point 25°C ±0.4% of full scale Overall accuracy 0 to 55°C ±0.8% of full scale Binary data with resolution of 6,000 A/D conversion data Full scale for −10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 0000 to 1770 hex Averaging Supported. Open-circuit detection Supported. Insulation resistance 20 MΩ. min. (at 250 VDC, between isolated circuits) Dielectric strength 500 VAC for 1 min (between isolated circuits) Isolation method Photocoupler isolation (between analog inputs and secondary internal circuits). No isolation between input signals. Conversion time 2.0 ms/point D/A conversion data Binary data with resolution of 6,000 Full scale for −10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 0000 to 1770 hex Insulation resistance 20 MΩ min. (at 250 VDC between isolated circuits) Dielectric strength 500 VAC for 1 min between isolated circuits Isolation method Photocoupler isolation between analog inputs and secondary internal circuits. No isolation between analog input signals. ■ Analog I/O Unit: CP1W-MAD11 Model CP1W-MAD11 Item Analog Input Section Analog Output Section Voltage I/O 2 inputs Input signal range 0 to 5 V, 1 to 5V, 0 to 10 V, or −10 to 10V Max. rated input ±15 V ±30 mA External input impedance 1 MΩ min. 250 Ω Resolution Overall accuracy 0 to 20 mA, 4 to 20 mA 1/6000 (full scale) 25°C ±0.3% of full scale ±0.4% of full scale 0 to 55°C ±0.6% of full scale ±0.8% of full scale A/D conversion data Binary data (hexadecimal, 4 digits) −10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 0000 to 1770 hex Averaging Supported (Set for each input using a DIP switch.) Disconnection detection Supported Number of outputs 1 output Output signal range 1 to 5 V, 0 to 10 V, −10 to 10 V External output max. current --- Allowable external output load resistance 1 kΩ min. 600 Ω max. External input impedance 0.5 Ω max. --- Resolution 1/6000 (full scale) Overall accuracy 25°C ±0.4% of full scale 0 to 55°C ±0.8% of full scale Data setting --- D/A conversion data Binary data (hexadecimal, 4 digits) −10 to 10 V: F448 to 0BB8 hex Full scale for other ranges: 0000 to 1770 hex 0 to 20 mA, 4 to 20 mA Conversion time* 2 ms/point (6 ms for all points) Isolation method Photocoupler isolation between analog I/O and internal circuits (There is no isolation between the analog I/O signals.) * The conversion time is the total time for 2 analog inputs and 1 analog output. 24 Current I/O Number o f inputs CP1L ■ Temperature Sensor Units: CP1W-TS001/TS002/TS101/TS102 By mounting a Temperature Sensor Unit to the PLC, inputs can be obtained from thermocouples or platinum resistance thermometers, and temperature measurements can be converted to binary data (4-digit hexadecimal) and stored in the input area of the CPU Unit. ● Specifications Item Model CP1W-TS001/002 CP1W-TS101/102 Number of inputs 2 (TS001), 4 (TS002) 2 (TS101), 4 (TS102) Input types K, J switchable (Note: Same for all inputs.) Pt100, JPt100 switchable (Note: Same for all inputs.) Indication accuracy (The larger of the indicated value: ±0.5% and ±2°C (See note.)) ±1 (The larger of the indicated value: ±0.5% and ±1°C) ±1 digit max. digit max. Conversion time 250 ms/2 points (TS001, TS101); 250 ms/4 points (TS002, TS102) Converted temperature data Binary (4-digit hexadecimal) Isolation method Photocoupler isolation between the temperature input signals. Note: The indication accuracy when using a K-type thermocouple for temperature less than −100°C is ±4°C±1 digit max. ● Input Temperature Ranges for CP1W-TS001/002 (The rotary switch can be used to make the following range and input type settings.) Input type K J Range (°C) Range (°F) −200 to 1300 −300 to 2300 0.0 to 500.0 0.0 to 900.0 −100 to 850 −100 to 1500 0.0 to 400.0 0.0 to 750.0 ● Input Temperature Ranges for CP1W-TS101/102 (The rotary switch can be used to make the following range and input type settings.) Input type Range (°C) Range (°F) Pt100 −200.0 to 650.0 −300 to 1200.0 JPt100 −200.0 to 650.0 −300 to 1200.0 ■ CP1W-SRT21 CompoBus/S I/O Link Unit The CompoBus/S I/O Link Unit functions as a slave for a CompoBus/S Master Unit (or an SRM1 CompoBus/S Master Control Unit) to form an I/O Link with 8 inputs and 8 outputs between the CompoBus/S I/O Link Unit and the Master Unit. CompoBus/S Master Unit (or SRM1 CompoBus/S Master Control Unit) CP1W-SRT21 CompoBus/S I/O Link Unit CP1L ● Specifications Item Model CP1W-SRT21 Master/Slave CompoBus/S Slave Number of I/O bits 8 input bits, 8 output bits Number of words occupied in CP1L I/O memory 1 input word, 1 output word (Allocated in the same way as for other Expansion Units) Node number setting Set using the DIP switch (before the CPU Unit is turned ON.) ON 1 2 3 4 5 6 No. COMM ERR SRT21 EXP BD H NC(BS+) BD L NC(BS-) NC CS/CJ Series C200H@ Series CQM1(H) Series SRM1 Series CPM2C-S Series Special flat cable or VCTF cable A maximum of 16 Units can be connected (or 8 Units for CQM1-SRM21-V1). 25 CP1L I/O Bits and I/O Allocations With CP1L CPU Units, the beginning input and output words (CIO 0 and CIO 100) are allocated by the CPU Unit one or two words at a time. I/O bits are allocated in word units in order of connection to Expansion Units and Expansion I/O Units connected to a CPU Unit. Allocated words CPU Unit Inputs CP1L CPU Unit with 10, 14, or 20 I/O points CIO 100 CIO 0 and CIO 1 CIO 100 and CIO 101 CIO 0, CIO 1, and CIO 2 CIO 100, CIO 101, and CIO102 CP1L CPU Unit with 30 or 40 I/O points CP1L CPU Unit with 60 I/O points Outputs CIO 0 ● Example: I/O Bit Allocations When Expansion Units Are Connected CPU Unit with 40 I/O Points + Temperature Sensor Unit + Analog Output Unit + Expansion I/O Unit with 40 I/O Points Inputs Outputs CPU Unit with 40 I/O Points CP1L-M40D@-@ CIO 0.00 to CIO 0.11 CIO 1.00 to CIO 1.11 24 inputs 16 outputs CIO 100.00 to CIO 100.07 CIO 101.00 to CIO 101.07 2nd Unit 1st Unit Temperature Sensor Unit Analog Output Unit CP1W-DA041 CP1W-TS002 CIO 2 to 5 None None CIO 102 to CIO 105 3rd Unit Expansion I/O Unit with 40 I/O Points CP1W-40ED CIO 6.00 to CIO 6.11 CIO 7.00 to CIO 7.11 24 inputs 16 outputs CIO 106.00 to CIO 106.07 CIO 107.00 to CIO 107.07 Expansion Unit and Expansion I/O Units Specifications ■ Maximum Number of CP1W/CPM1A Expansion Unit and Expansion I/O Units ● CP1L (EM, EL, M) CPU Units with 60, 40, or 30 Points 3 max. ● CP1L (L) CPU Units with 20 or 14 Points 1 max. 26 Note: CP1L (L Type) CPU Units with 10 points do not support Expansion Units. CP1L Current Consumption The power consumption shown on page 6 is the maximum power consumption. To obtain the correct power consumption for the system configuration, calculate the power consumption for the external power supply from the current consumption given below for the CPU Unit, Expansion Units, and Expansion I/O Units. ● CPU Units Current consumption Model External power supply 5 VDC 24 VDC 24 VDC * CP1L-EM40DR-D @@@ @@@ --- CP1L-EM40DT-D @@@ @@@ --- CP1L-EM40DT1-D @@@ @@@ --- CP1L-EM30DR-D @@@ @@@ --- CP1L-EM30DT-D @@@ @@@ --- CP1L-EM30DT1-D @@@ @@@ --- CP1L-EL20DR-D @@@ @@@ --- CP1L-EL20DT-D @@@ @@@ --- CP1L-EL20DT1-D @@@ @@@ --- CP1L-M60DR-A 0.25 A 0.14 A 0.3 A max. (0.5 A max.) CP1L-M60DT-A 0.39 A 0.03 A 0.3 A max. (0.6 A max.) CP1L-M60DR-D 0.25 A 0.14 A --- CP1L-M60DT-D 0.39 A 0.03 A --- CP1L-M60DT1-D 0.39 A 0.03 A --- CP1L-M40DR-A 0.22 A 0.08 A 0.3 A max. (0.6 A max.) CP1L-M40DT-A 0.31 A 0.03 A 0.3 A max. (0.6 A max.) CP1L-M40DR-D 0.22 A 0.08 A --- CP1L-M40DT-D 0.31 A 0.03 A --- CP1L-M40DT1-D 0.31 A 0.03 A --- CP1L-M30DR-A 0.21 A 0.07 A 0.3 A max. (0.6 A max.) CP1L-M30DT-A 0.28 A 0.03 A 0.3 A max. (0.6 A max.) CP1L-M30DR-D 0.21 A 0.07 A --- CP1L-M30DT-D 0.28A 0.03 A --- CP1L-M30DT1-D 0.28 A 0.03 A --- CP1L-L20DR-A 0.20 A 0.05 A 0.2 A max. CP1L-L20DT-A 0.24 A 0.03 A 0.2 A max. CP1L-L20DR-D 0.20A 0.05 A --- CP1L-L20DT-D 0.24 A 0.03 A --- CP1L-L20DT1-D 0.24 A 0.03 A --- CP1L-L14DR-A 0.18 A 0.04 A 0.2 A max. CP1L-L14DT-A 0.21 A 0.03 A 0.2 A max. CP1L-L14DR-D 0.18 A 0.04 A --- CP1L-L14DT-D 0.21 A 0.03 A --- CP1L-L14DT1-D 0.21 A 0.03A --- CP1L-L10DR-A 0.16 A 0.03 A 0.2 A max. CP1L-L10DT-A 0.18 A 0.03 A 0.2 A max. CP1L-L10DR-D 0.16 A 0.03A --- CP1L-L10DT-D 0.18 A 0.03 A --- CP1L-L10DT1-D 0.18 A 0.03 A --- Note: 1. The current consumption of the CP1W-ME05M Memory Cassette and the CP1W-CIF01/CIF11 Option Boards are included in the current consumption of the CPU Unit. 2. The current consumption of the following is not included with the current consumption of the CPU Unit: CP1W-CIF12. Unit Interface Unit Model CP1W-CIF12 Curent consumption 5 VDC 24 VDC 0.075A --- EXternal power supply --- 3. CPU Units with DC power do not provide an external power supply. 4. The current consumptions given in the following table must be added to the current consumption of the CPU Unit if an Expansion Unit or Expansion I/O Unit is connected. 5. The external power supply cannot be used if an Expansion Unit or Expansion I/O Unit is connected to a CPU Unit with 14 or 20 I/O points. * Values in parentheses are the maximum external power supply for a CPU Unit to which an Expansion I/O Unit is not connected. Refer to the CP1L CPU Unit Operation Manual (Cat. No. W462). 27 CP1L ● Expansion Units and Expansion I/O Units Unit name Model 40 I/O points 24 inputs 16 outputs CP1W-40EDR CP1W-40EDT1 Expansion I/O Units CP1W-20EDR1 CP1W-20EDT1 8 outputs Analog Output Unit Analog I/O Unit Temperature Sensor Units CompoBus/S I/O Link Unit --- 0.049 A 0.131 A 0.113 A --- 0.103 A 0.044 A 0.130 A --- 0.042 A 0.090 A 0.076 A --- CP1W-8ED 0.018 A --- CP1W-8ER 0.026 A 0.044 A 0.075 A --- CP1W-8ET CP1W-8ET1 Analog Input Unit 0.160 A CP1W-16ET CP1W-16ET1 8 inputs 0.090 A CP1W-20EDT CP1W-16ER 16 outputs 0.080 A CP1W-32ET CP1W-32ET1 20 I/O points 12 inputs 8 outputs 24 VDC CP1W-40EDT CP1W-32ER 32 outputs* Current consumption 5 VDC 4 inputs CP1W-AD041 0.100 A 0.090 A 4 outputs CP1W-DA041 0.080 A 0.124 A 2 outputs CP1W-DA021 0.095 A 0.040 A 2 inputs and 1 output CP1W-MAD11 0.083 A 0.110 A K or J thermocouple inputs CP1W-TS001 0.040 A 0.059 A Pt or JPt platinum resistance thermometer inputs CP1W-TS101 0.054 A 0.073 A 8 inputs and 8 outputs CP1W-SRT21 0.029 A --- CP1W-TS002 CP1W-TS102 * CP1W-32ER/32ET/32ET1’s maximum number of simultaneously ON points is 24 (75%). ● Others : Equipment that Users internal power supply of PLC Unit name Model 24 VDC CJ1W-CIF11 0.04A --- NT-AL001 0.15A --- Backlight (Green/Orange/red) NV3W-MG20L 0.2A --- Backlight (White/Pink/Red) NV3W-MR20L 0.2A --- Link Adapter Programable Terminal NV3W 28 Current consumption 5 VDC CP1L Dimensions (Unit: mm) ■ CPU Units CP1L-EM CPU Units with 40 Points 150 85 140 8 Weight: 675 g max. 110 100 90 Four, 4.5 dia. CP1L-EM CPU Units with 30 Points 130 85 120 8 Weight: 610 g max. 110 100 90 Four, 4.5 dia. CP1L-EL CPU Units with 20 Points 130 85 120 8 Weight: 610 g max. 110 100 90 Four, 4.5 dia. 29 CP1L CP1L CPU Units with 60 I/O Points 195 85 185 8 Weight: 820 g max. 110 100 90 Four, 4.5 dia. CP1L CPU Units with 40 I/O Points 150 85 140 8 Weight: 675 g max. 110 100 90 Four, 4.5 dia. CP1L CPU Units with 30 I/O Points 130 85 120 8 Weight: 610 g max. 110 100 90 Four, 4.5 dia. 30 CP1L CP1L CPU Units with 14 or 20 I/O Points 86 85 76 8 Weight: 380 g max. 110 100 90 Two, 4.5 dia. CP1L CPU Units with 10 I/O Points 66 85 56 8 Weight: 300 g max. 110 100 90 Two, 4.5 dia. 31 CP1L ■ Expansion Units and Expansion I/O Units CP1W-8E@@ CP1W-SRT21 CP1W-20ED@ CP1W-16E@@ CP1W-AD041/CP1W-DA041/CP1W-DA021 CP1W-MAD11/CP1W-TS@@@ COM 01 03 05 07 09 11 00 02 04 06 08 10 NC COM 01 00 CH IN 03 02 IN CH 00 01 02 03 04 05 06 07 CH 00 01 02 03 08 09 10 11 08 09 10 11 90 20EDR1 90 8ED OUT CH NC 00 01 02 03 04 05 06 07 CH 00 01 02 04 05 07 NC COM COM COM 03 COM 06 EXP EXP 04 COM 86 06 05 66 50 Unit name CP1W-40ED@ CP1W-32E@@ Model number NC COM NC NC 01 00 03 02 05 04 07 06 CH 09 08 11 10 01 00 03 02 05 04 07 06 09 08 380 g 320 g CP1W-32ER 465 g CP1W-32ET/-32ET1 325 g CP1W-20EDR1/-20EDT/-20EDT1 300 g CP1W-16ER 280 g CP1W-16ET/-16ET1 225 g CP1W-8ED 200 g CP1W-8ER/-8ET/-8ET1 250 g CP1W-AD041/-DA041/-DA021 200 g CP1W-MAD11 150 g Temperature Sensor Units CP1W-TS001/-TS002/-TS101/ -TS102 250 g CompoBus/S I/O Link Unit CP1W-SRT21 200 g 11 10 CH CH IN 00 01 02 03 04 07 08 09 10 11 00 01 02 03 04 05 06 07 08 09 10 11 00 01 02 03 04 05 05 06 06 07 CH CH 110 100 90 CH 00 01 02 03 04 05 06 40EDR 07 CH CH NC 00 01 02 04 05 07 00 02 04 05 07 NC COM COM COM 03 COM 06 COM 01 03 COM 06 Analog Units EXP Four, 4.5 dia. 8 50 ■ CJ-series Special I/O Units and CPU Bus Units ■ CJ Unit Adaptor CP1W-EXT01 2.7 2.7 16.4 5.7 90 65.5 65 7.6 90 95.4 90 2.7 31 65 2.7 31 89 65.5 32 Weight CP1W-40EDT/-40EDT1 Expansion I/O Units NC 50 CP1W-40ER 150 140 OUT 07 CP1L Related Manuals Cat. No. Model numbers Manual name Description CP1L-L10D@-@ CP1L-L14D@-@ CP1L-L20D@-@ CP1L-M30D@-@ CP1L-M40D@-@ CP1L-M60D@-@ CP Series CP1L CPU Unit Operation Manual Provides the following information on the CP Series: • Overview, design, installation, maintenance, and other basic specifications • Features • System configuration • Mounting and wiring • I/O memory allocation • Troubleshooting Use this manual together with the CP1H Programmable Controllers Programming Manual (W451). CP Series CP1H/CP1L CPU Unit Programming Manual W451 CP1H-X40D@-@ CP1H-XA40D@-@ CP1H-Y20DT-D CP1L-L10D@-@ CP1L-L14D@-@ CP1L-L20D@-@ CP1L-M30D@-@ CP1L-M40D@-@ CP1L-M60D@-@ Provides the following information on programming the CP Series: • Programming methods • Tasks • Programming instructions CP Series CP1L CPU Unit Introduction Manual W461 CP1L-L10D@-@ CP1L-L14D@-@ CP1L-L20D@-@ CP1L-M30D@-@ CP1L-M40D@-@ CP1L-M60D@-@ Describes basic setup methods of CP1L PLCs: • Basic configuration and component names • Mounting and wiring • Programming, data transfer, and debugging using the CX-Programmer • Application program examples CS1G/CS1H/CS1D/CS1W/CJ2H/CJ2M/ CJ1G/CJ1H/CJ1M/CJ1W/CP1H/CP1L/ CP1E/NSJ SYSMAC CS/CJ/CP/NSJ Series Communications Commands REFERENCE MANUAL Describes the communications commands used with CS-series, CJ-series, and CP-series PLCs and NSJ Controllers. W342 SYSMAC CS/CJ/CP/NSJ Series CS1G/H-CPU@@-EV1, CS1G/H-CPU@@H, CS1D-CPU@@H, CS1D-CPU@@S, CJ1H-CPU@@H-R,CJ1G-CPU@@, CJ1M-CPU@@, CJ1G-CPU@@P, CJ1G/H-CPU@@H, CJ2H-CPU6@-EIP, CJ2H-CPU6@,CJ2M-CPU@@, CS1W-SCU@@-V1, CS1W-SCB@@-V1, CJ1W-SCU@@-V1, CP1H-X@@@@-@, CP1H-XA@@@@-@,CP1H-Y@@@@-@, CP1L-M/L@@@-@, CP1E-E@@D@-@, CP1E-N@@D@-@, NSJ@-@@@@(B)-G5D, NSJ@-@@@@(B)-M3D Communications Commands Reference Manual W462 33 MEMO 34 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2012 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. Printed in Japan Cat. No. P81-E1-01 @@@@ (0507)
CP1L-EM30DT1-D 价格&库存

很抱歉,暂时无法提供与“CP1L-EM30DT1-D”相匹配的价格&库存,您可以联系我们找货

免费人工找货