0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
D2SW-3L3D

D2SW-3L3D

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    OMRON ELECTRONIC COMPONENTS - D2SW-3L3D - Microswitch, Subminiature, Simulated Roller Lever, SPDT, S...

  • 数据手册
  • 价格&库存
D2SW-3L3D 数据手册
Sealed Snap Action Switch D2SW Watertight Miniature Snap Action Switch • High-quality watertight miniature Snap Action switch. Switch Body meets IP67 (IEC 529) requirements • Monoblock construction assures high sealing capability and is ideal for dusty places or where water is sprayed • Wide operating temperature range of -40°C to 85°C • Perfect for the automobile, agriculture machinery, automatic vending machine, refrigerator, ice-manufacturing, hot-water supply, air conditioner, and industrial equipment, which require highly environment-resistive capabilities • RoHS Compliant Ordering Information Actuator Terminal Model 3 A Model 0.1 A Pin plunger Solder terminals D2SW-3HS D2SW-01HS Quick-connect terminals (#110) D2SW-3TS D2SW-01TS PCB terminals D2SW-3DS D2SW-01DS With lead wires D2SW-3MS D2SW-01MS Hinge lever Simulated roller lever Hinge roller lever Model Solder terminals D2SW-3L1HS D2SW-01L1HS Quick-connect terminals (#110) D2SW-3L1TS D2SW-01L1TS PCB terminals D2SW-3L1DS D2SW-01L1DS With lead wires D2SW-3L1MS D2SW-01L1MS Solder terminals D2SW-3L3HS D2SW-01L3HS Quick-connect terminals (#110) D2SW-3L3TS D2SW-01L3TS PCB terminals D2SW-3L3DS D2SW-01L3DS With lead wires D2SW-3L3MS D2SW-01L3MS Solder terminals D2SW-3L2HS D2SW-01L2HS Quick-connect terminals (#110) D2SW-3L2TS D2SW-01L2TS PCB terminals D2SW-3L2DS D2SW-01L2DS With lead wires D2SW-3L2MS D2SW-01L2MS Note: 1. “S” at the end of the part number signifies UL/CSA approved models. 2. The standard lengths of the lead wires (UL1015 AWG22 for UL/CSA models, AV0.5f otherwise.) of models incorporating them are 30 cm. Model Number Legend D2SW1 2 3 4 1. Ratings 3: 3 A at 125 VAC 01: 0.1 A at 30 VDC 2. Actuator None: Pin plunger L1: Hinge lever L2: Hinge roller lever L3: Simulated roller lever 3. Contact Form None: SPDT -2: SPST-NC* -3: SPST-NO* *Lead wire versions only 4. Terminals H, HS: Solder terminals (HS for UL and CSA approval) D, DS: PCB terminals (DS for UL and CSA approval) T, TS: Quick-connect terminals (#110) (TS for UL and CSA approval) M, MS: Molded lead wires (MS for UL and CSA approval) Sealed Snap Action Switch D2SW 195 Specifications ■ Characteristics Item D2SW-3 D2SW-01 Operating speed 0.1 mm to 1 m/second (at pin plunger) Operating frequency Mechanical: 300 operations/minute max. Electrical: 30 operations/minute max. Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 30 mΩ max. for terminal models 50 mΩ max. for terminal models 50 mΩ max. for lead wire models 70 mΩ max. for lead wire models 1,000 VAC, 50/60 Hz for 1 min. between terminals of the same polarity 600 VAC, 50/60 Hz for 1 min. between terminals of the same polarity Dielectric strength (See note 2) 1,500 VAC, 50/60 Hz for 1 min. between current-carrying metal parts and ground, and between each terminal and noncurrent-carrying metal parts Vibration resistance (See note 3) Malfunction: 10 to 55 Hz, 1.5 mm double amplitude Shock resistance (See note 3) Destruction: 1,000 m/s2 (approx. 100G) max. Malfunction: 300 m/s2 (approx. 30G) max. Ambient operating temperature -40° to 85°C (at 60% RH) with no icing Ambient operating humidity 95% max. (for 5°C to 35°C) Degree of protection IEC IP67 (excluding the terminals on terminal models) Degree of protection against electric shock Class I Proof tracking index (PTI) 175 Life expectancy Weight Mechanical 5,000,000 operations min. at 60 operations per minute Electrical (30 operations per minute) 200,000 operations min. (3 A at 125 VAC) 200,000 operations min. 100,000 operations min. (2 A at 250 VAC) (at rated resistive load) Terminal model Approx. 2 g Lead wire model Approx. 10 g Note: 1. Data shown are of initial value. 2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate 3. For pin plunger models, the above values apply for use at the free position, operating position, and total travel position. For models with levers, the values apply at the total travel position. ■ Ratings (reference values) D2SW-3 Rated Voltage Non-inductive load (A) Resistive load NC 125 VAC NO 3A Inductive load Lamp load NC NO 1A 0.5 A 0.3 A 250 VAC 2A 0.5 A 30 VDC 3A 1A Inductive load NC Motor load NO 1A 0.5 A 0.5 A 0.3 A 1A NC NO 1A 0.5 A 0.5 A 0.3 A 1A D2SW-01 Rated Voltage Non-inductive load Resistive load NC Inductive load Lamp load NO NC Inductive load NO NC Motor load NO NC 125 VAC 0.1 A — — — 30 VDC 0.1 A — — — Note: 1. The resistive load ratings apply under the following test conditions: Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min. 2. The above current ratings are the values of the steady-state current. 3. Inductive load has a power factor of 0.7 min. (AC) and a time constant of 7 ms max. (DC). 4. Lamp load has an inrush current of 10 times the steady-state current. 5. Motor load has an inrush current of 6 times the steady-state current. 196 Sealed Snap Action Switch D2SW NO ■ Approvals ■ Contact Specifications Consult your OMRON sales representative for specific models with standard approvals. Item Specification Material Gap (standard value) Inrush current D2SW-3 Rivet Silver 0.5 mm NC: 20 A max. NO: 10 A max. Minimum applicable load 160 mA at 5 VDC (see note) UL Recognized, CSA Certified Rated Voltage D2SW-3 D2SW-01 125 VAC 250 VAC 3A 2A 0.1 A --- 30 VDC 3A 0.1 A Rated Voltage 1 A max. 1 mA at 5 VDC Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60% (λ60) reliability level (JIS C5003). The equation λ60=0.5 x 10-6 / operations indicates that a failure rate of 1/2,000,000 operations can be expected at a reliability level of 60% EN 61058-1 (VDE Approval) 125 VAC D2SW-01 Crossbar Gold alloy D2SW-01 0.1 A Testing conditions: 5E4 (50,000 operations), T85 (0°C to 85°C) Engineering data ■ Mounting ■ PCB Layout (reference) All switches may be panel mounted using M2.3 mounting screws with plane washers or spring washers to securely mount the switch. Tighten the screws to a torque of 0.23 to 0.26 N·m. Panel Mounting PCB Mounting Three, 1.35-dia. to 1.5 holes Two, 2.4-dia. mounting hole or M2.3 screw hole 8.8±0.2 16.1±0.2 9.5 ■ Structure SPDT SPST-NC NC COM NO (Black*) (Blue*) (Red*) COM (Black) SPST-NO COM (Black) NC (Red) NO (Blue) *Indicates the color of the lead wire. Sealed Snap Action Switch D2SW 197 Dimensions ■ Terminals Note: Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions Solder Terminals (HS) Quick-connect Terminals (#110) (TS) 3.3±0.1 3.3±0.1 2.9 2.9 7.3 1.8 10.1 Three, 1.2 dia. holes Three, 2.8 6.6 1.6 8.5±0.2 5.15 9.5±0.1 0.55 0.8R 1.6 3.2 0.5 8.7±0.2 5.15 9.5±0.1 6.4±0.2 15.5±0.2 18.7±0.2 0.5 6.4±0.2 15.5±0.2 19.8±0.2 2.15 19.8±0.2 Molded Lead Wires PCB Terminals (DS) 16.4 16.9 3.3±0.1 1.8±0.1 2.9 9.2 7.2 3.9 0.8 1.2 8.8±0.2 5.15 9.5±0.1 1.85 0.7 0.5 300±10 1.3 6.4±0.2 16.1±0.2 19.8±0.2 Common terminal (black) (see note) Vinyl insulator (5) Normally open terminal (blue) (see note) 0.7 9.5±0.1 5.15 21.2 Normally closed terminal 6.4±0.2 (red)* Stranded annealed copper wires * UL/CSA approved models have UL approved AWG22 wiring. 198 Sealed Snap Action Switch D2SW ■ Dimensions and Operating Characteristics Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions 2. Omitted dimensions are the same as pin plunger type. 3. The following illustrations and dimensions are for models with solder terminals. Refer to “Terminals” for models with quick-connect (#110) and PCB terminals. 4. The operating characteristics are for operation in the A direction( ) Pin Plunger Models 7.5±0.1 D2SW-3@S D2SW-01@S 1.8 dia. 2.35 +0.1 –0.05 dia. holes A PT OF 2.35 +0.1 –0.05 3.3±0.1 10.1 7.3 S RF min. 30 gf 2.9 PT max. 0.6 mm OT min. 0.5 mm 1.8 1.6 2.5 dia.±0.07 8.5±0.2 5.15 9.5±0.1 180 gf 7.7 OP MD max. 0.8R 1.6 3.2 0.5 6.4±0.2 0.1 mm OP 8.4 ± 0.3 mm OF 60 gf 15.5±0.2 18.7±0.2 19.8±0.2 0.55 Hinge Lever Models D2SW-3L1@S D2SW-01L1@S t = 0.3 Stainless-steel lever 5.9 3.6 A 14.5 OP S FP RF min. 6 gf OT min. 1.0 mm MD max. 0.8 mm FP max. 13.6 mm OP 8.8 ± 0.8 mm 5.9 OF 60 gf 3.6 RF min. 6 gf OT min. 1.0 mm Simulated Roller Lever Models D2SW-3L3@S D2SW-01L3@S A t = 0.3 Stainless-steel lever 15.8 1.3R OP FP S MD max. 0.8 mm FP max. 15.5 mm OP 10.7 ± 0.8 mm OF 60 gf Hinge Roller Lever Models D2SW-3L2@S D2SW-01L2@S A 5.9 14.5 t = 0.3 Stainless-steel lever OP FP S 4.8 dia. 3.2 Polyacetal roller RF min. 6 gf OT min. 1.0 mm MD max. 0.8 mm FP max. 19.3 mm OP Sealed Snap Action Switch 14.5 ± 0.8 mm D2SW 199 Precautions Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide, “Snap Action Switches, Technical Information” for correct use. ■ Correct Use ■ Cautions Operation stroke Degree of Protection Make sure that the switching object is perfectly separated from the actuator when the switch is not operated and the actuator is pressed appropriately by the switching object when the switch is operated. The D2SW was tested under water and passed the following watertightness test, which however, does not mean that the D2SW can be used in the water. JIS C0929 (rules for testing the watertightness of electrical devices and materials), class 7 (watertightness test). Refer to the following illustration for the test method. The switch should be set so that its stroke will be within the rated OT when the switch is operated. IEC Publication 529, class IP67. Refer to the following illustration for the test method. Handling Install the switching object so that its moving direction is the same as that of the actuator. With the pin plunger models, set the switch so that the plunger can be actuated from directly above. Since the plunger is covered with a rubber cap, applying a force from lateral directions may cause damage to the plunger or reduction in the sealing capability. Correct Incorrect Incorrect Note: The object to be tested is left in the water for 30 minutes on condition that the distance between the surface of the water and the top of the object be 15 cm minimum, and the distance between the surface of the water and the bottom of the object be 1 m minimum. Protection Against Chemicals Handle D2SW models with pin plungers with care so that the sealing rubber parts around the pin plungers will not be damaged. Make sure that there is no icing when using the D2SW at low ambient temperatures. Using Microloads Voltage (V) Using a model for ordinary loads to switch microloads may result in faulty operation. Instead, use the models that are designed for microloads and that operate in the following range; Operating range for micro load models D2SW-01 Operating range for general-load models D2SW-3 Inoperable range Current (mA) However, even when using microload models within the operating range shown above, if inrush current or inductive voltage spikes occur when the contact is opened or closed, then contact wear may increase and so decrease the service life. Therefore, insert a contact protection circuit where necessary. 200 Sealed Snap Action Switch D2SW Prevent the switch from coming into contact with oil and chemicals. Otherwise, damage and deterioration to the switch materials may occur. Soldering When soldering a lead wire to a terminal of the D2SW, use a soldering iron with a maximum capacity of 30 W and do not take more than 5 seconds to solder the lead wire, otherwise the characteristics of the D2SW may be altered. MEMO Sealed Snap Action Switch D2SW All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X303-E-1 11/10 Sealed Snap Action Switch Specifications subject to change without notice D2SW Printed in USA
D2SW-3L3D 价格&库存

很抱歉,暂时无法提供与“D2SW-3L3D”相匹配的价格&库存,您可以联系我们找货

免费人工找货