High-Coded Non-Contact Safety Door Switch
D41D
Matches with machine design.
Initial setup by batch pairing is
quick and easy.
• Tamper-proof safety door switch to prevent human error
• Easy automatic pairing
• Fits in narrow spaces and corners inside machines
• Three types of actuators
• Complies with ISO 14119 (Type 4/High Coded),
ISO 13849-1 (PLe)
Refer to Safety Precautions on page 17
* The actuator is sold separately.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Three types of actuators fit in narrow spaces and corners inside machines
D41D-A1
Installation example: swinging door
• Fits in narrow spaces and corners
D41D-A2
Installation example: acrylic glass door
• Flat design matches the surroundings
D41D-A3
Installation example: sliding door, narrow space
• Compact size for acrylic glass doors
A high-coded safety switch is defined as one where a sensor is paired with a high level coded actuator for which more than 1,000
variations are available.
1
D41D
Model Number Structure
Model Number Legend
Safety Door Switch
Sensor
D41D - @ C D - @ @
(1)
(2) (3) (4)
(5) (6)
(1) Model
D: Non-Contact
(2) Coding level / Teaching limitation
1: High (Individual coding)
2: High (Individual coding, No limitation)
(3) Connection to controller
C: Cascade connection
(4) Diagnosis output
D: With diagnosis output
(5) Cable length
Blank: no cable
025: 25cm
(6) Connector
N1: M8
N2: M12
Actuator
D41D - A @
(1)
(2)
(1) Model
D: Non-contact
(2) Actuator type
A1: Standard
A2: Flat
A3: Miniature
2
D41D
Ordering Information
List of Models
Sensors
Appearance
Coding level / Teaching limitation
Connection
Cable length
High
(Individual coding)
Connector (M8)
High
(Individual coding/No limitation)
Connecting cable 0.25-m long with
Connector (M12)
---
Model
D41D-1CD-N1
D41D-2CD-025N2
Actuator (Sold separately)
Appearance
Name
Features
Model
Standard
• Mounting 2 x M4
• Dimensions (W x D x H) 39 x 29.5 x 18 (mm)
D41D-A1
Flat
• Mounting 2 x M5 (Countersunk screw)
• Dimensions (W x D x H) 60 x 16 x 6.8 (mm)
D41D-A2
Miniature
• Mounting 1 x M3 (1.2 dia. hole, plus Twist protection)
• Dimensions (W x D x H) 22 x 9 x 7 (mm)
D41D-A3
Accessory (Sold separately)
Connecting cables
Appearance
Name
Features
Connecting cables with
Connector M8
Connecting cables with
Connector M12
Connecting cables
with Connector (M8) (female),
8-pole – 8 x 0.25mm2,
straight, IP67
Connecting cables
with Connector (M12) (female),
8-pole – 8 x 0.25mm2,
straight, IP69
Cable length
Model
2m
D41D-8P5-CFM8-702M
5m
D41D-8P5-CFM8-705M
10 m
D41D-8P5-CFM8-710M
5m
D41L-8P5-CFM12-905M
10 m
D41L-8P5-CFM12-910M
Sealing /Mounting
Appearance
Name
Purpose
Contents
Model
Sealing Kit
Used to seal the mounting holes
4 flat plugs and 4 plugs
with rim for high screw
head
D41D-SK
Mounting Set
Mounting plate:
Used to fix to a non-flat surface such as a
profile.
2 mounting plates and
Ferrule plug:
4 ferrule plugs
Used for applications with considerable
changes in ambient temperature.
D41D-MS
3
D41D
Standards Certification
EU Declaration of Conformity
•
•
•
•
Machinery Directive
RE Directive
RoHS Directive
WEEE Directive
Dispose in accordance with applicable regulations.
Standards
•
•
•
•
•
•
EN ISO 13849-1: 2015 PL e Category 4
EN 60947-5-3
EN 300 330
EN ISO 14119
IEC 61508
EN 62061
UL Certification
• UL508
• CAN/CSA C22.2 No.14
Regions where D41D can be used
The product can be used in Japan, the United States of America, Canada, EU member states, the United Kingdom, and People's Republic of China.
The use in other countries may conflict with radio laws of the countries.
4
D41D
Ratings and Specifications
Model
D41D
Technical
Detection method
RFID
Frequency band
125 kHz
Transmitter outputs
-6 dBm max.
Interlock type (ISO 14119)
Type 4
Coded level (ISO 14119)
D41D-1: High (individual coding)
D41D-2: High (individual coding, No limitation)
Actuator
D41D-A1, D41D-A2, D41D-A3
Response time (ON to OFF)
100 ms max.
Risk time
200 ms max.
Startup time
2 s max.
Typical operating distance
(Sn)
(IEC 60947-5-3)
12 mm
(lateral actuation: 9 mm)
Assured operating distance
(Sao)
(IEC 60947-5-3)
10 mm (-10 to 60°C)
6 mm (-10 to 60°C, lateral)
8 mm (-25 to 65°C)
4 mm (-25 to 65°C, lateral)
Assured switch-off distance
(Sar)
18 mm
(lateral actuation: 15 mm)
Differential travel
很抱歉,暂时无法提供与“D41D-2CD-025N2”相匹配的价格&库存,您可以联系我们找货