0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G3PB445B3VDDC1224

G3PB445B3VDDC1224

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Relay SSR 10mA 30V DC-IN 45A 440V AC-OUT 8-Pin

  • 数据手册
  • 价格&库存
G3PB445B3VDDC1224 数据手册
Solid State Contactors (Three-phase) G3PB-2/-3 CSM_G3PB-2_-3_DS_E_2_1 Compact, Low-cost Solid State Contactors of an Innovative Construction Ideal for Three-phase Heaters • Slim Units with three-phase output. • Optimum heat sinks attach to models without built-in heat sinks. • Compact design achieved by optimizing heat sink shape. • DIN track mounting possible (when using the Y92B-P50 Heat Sink) in addition to screw mounting. • Comply with EN60947-4-3 (IEC947-4-3) UL508, and CSA22.2 No. 14, and bear CE marking. Refer to Safety Precautions for All Solid State Relays. Model Number Structure ■ Model Number Legend G3PB-@@@-@@-@ 1 2 3 4 5 6 7 1. Basic Model Name G3PB: Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 4: 400 VAC 3. Rated Load Current 15: 15 A 25: 25 A 35: 35 A 45: 45 A 4. Terminal Type B: Screw terminals 5. Single-phase/3-phase and Number of Elements for 3-phase 2: 3-phase, 2-element models 3: 3-phase, 3-element models 6. 3-phase Type Blank: Built-in heat sink H: No heat sink (“hockey puck” type) 7. Certification VD: Certified by UL, CSA, and VDE 1 G3PB-2/-3 Ordering Information ■ List of Models Models with Built-in Heat Sinks Number of phases 3 Main circuit voltage 100 to 240 VAC Zero cross function Yes Applicable load current (with Class-1 AC resistive load) Number of elements 15 A max. 25 A max. 35 A max. 45 A max. 200 to 400 VAC 15 A max. 25 A max. 35 A max. 45 A max. Model 3 G3PB-215B-3-VD 2 G3PB-215B-2-VD 3 G3PB-225B-3-VD 2 G3PB-225B-2-VD 3 G3PB-235B-3-VD 2 G3PB-235B-2-VD 3 G3PB-245B-3-VD 2 G3PB-245B-2-VD 3 G3PB-415B-3-VD 2 G3PB-415B-2-VD 3 G3PB-425B-3-VD 2 G3PB-425B-2-VD 3 G3PB-435B-3-VD 2 G3PB-435B-2-VD 3 G3PB-445B-3-VD 2 G3PB-445B-2-VD Note: 1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in, Engineering Data on page 7. 2. When ordering, specify the rated input voltage. Models without Built-in Heat Sinks Number of phases 3 Main circuit voltage Zero cross function 100 to 240 VAC Yes Applicable load current 15 A max. 25 A max. 200 to 400 VAC Number of elements Model 3 G3PB-215B-3H-VD 2 G3PB-215B-2H-VD 3 G3PB-225B-3H-VD 2 G3PB-225B-2H-VD 35 A max. 3 G3PB-235B-3H-VD 2 G3PB-235B-2H-VD 45 A max. 3 G3PB-245B-3H-VD 2 G3PB-245B-2H-VD 15 A max. 25 A max. 3 G3PB-415B-3H-VD 2 G3PB-415B-2H-VD 3 G3PB-425B-3H-VD 2 G3PB-425B-2H-VD 35 A max. 3 G3PB-435B-3H-VD 2 G3PB-435B-2H-VD 45 A max. 3 G3PB-445B-3H-VD 2 G3PB-445B-2H-VD Note: 1. The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in, Engineering Data on page 7. 2. When ordering, specify the rated input voltage. ■ Accessories (Order Separately) Heat Sinks Heat resistance (°C/W) Model 50 cm (1) x 7.3 mm (t) PFP-50N 1.67 Y92B-P50 Mounting Track 1 m (1) x 7.3 mm (t) PFP-100N 1.01 Y92B-P100 1 m (1) x 16 mm (t) PFP-100N2 0.63 Y92B-P150 0.43 Y92B-P200 0.36 Y92B-P250 2 G3PB-2/-3 Specifications ■ Ratings (at an Ambient Temperature of 25°C) Operating Circuit (Common) Item Common Rated voltage 12 to 24 VDC Operating voltage range 9.6 to 30 VDC Rated input current 10 mA max. (at 24 VDC) Must operate voltage 9.6 VDC max. Must release voltage 1 VDC min. Insulation method Phototriac Operation indicator Yellow LED Main Circuit of Models with Built-in Heat Sinks Item G3PB215B-3-VD G3PB215B-2-VD G3PB225B-3-VD G3PB225B-2-VD G3PB235B-3-VD G3PB235B-2-VD Rated load voltage 100 to 240 VAC Load voltage range 75 to 264 VAC Applicable load current (See note.) 0.2 to 15 A at 40°C 0.2 to 25 A at 40°C 0.5 to 35 A at 25°C Inrush current resistance (peak value) 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) Permissible I2t (half 60-Hz wave) 121 A2s 260 A2s 1260 A2s Applicable load (with Class-1 AC resistive load) 5.1 kW max. (at 200 VAC) 8.6 kW (at 200 VAC) 12.1 kW max. (at 200 VAC) Item G3PB415B-3-VD G3PB415B-2-VD G3PB425B-3-VD G3PB425B-2-VD G3PB435B-3-VD Rated load voltage 200 to 400 VAC Load voltage range 180 to 440 VAC Applicable load current (See note.) 0.5 to 15 A at 40°C Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) Permissible I2t (half 60-Hz wave) 260 A2s 260 A2s 1260 A2s Applicable load (with Class-1 AC resistive load) 10.3 kW max. (at 400 VAC) 17.3 kW max. (at 400 VAC) 24.2 kW max. (at 400 VAC) 0.5 to 25 A at 40°C G3PB245B-3-VD G3PB245B-2-VD 0.5 to 45 A at 25°C 15.5 kW max. (at 200 VAC) G3PB435B-2-VD 0.5 to 35 A at 25°C G3PB445B-3-VD G3PB445B-2-VD 0.5 to 45 A at 25°C 440 A (60 Hz, 1 cycle) 31.1 kW max. (at 400 VAC) Note: The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in, Engineering Data on page 7. 3 G3PB-2/-3 Main Circuit of Models without Built-in Heat Sinks Item G3PB-215B- G3PB-215B- G3PB-225B- G3PB-225B- G3PB-235B- G3PB-235B- G3PB-245B- G3PB-245B3H-VD 2H-VD 3H-VD 2H-VD 3H-VD 2H-VD 3H-VD 2H-VD Rated load voltage 100 to 240 VAC Load voltage range 75 to 264 VAC Applicable load current (See note.) 0.2 to 15 A at 40°C 0.2 to 25 A at 40°C 0.2 to 35 A at 25°C Inrush current resistance (peak value) 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) Permissible I2t (half 60-Hz wave) 121 A2s 260 A2s 1260 A2s Applicable load (with Class-1 AC resistive load) The applicable load varies with the heat radiation of the Unit. Refer to page 7, Engineering Data for details. Item 0.2 to 45 A at 25°C G3PB-415B- G3PB-415B- G3PB-425B- G3PB-425B- G3PB-435B- G3PB-435B- G3PB-445B- G3PB-445B3H-VD 2H-VD 3H-VD 2H-VD 3H-VD 2H-VD 3H-VD 2H-VD Rated load voltage 200 to 400 VAC Load voltage range 180 to 440 VAC Applicable load current (See note.) 0.5 to 15 A at 40°C Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) Permissible I2t (half 60-Hz wave) 260 A2s Applicable load (with Class-1 AC resistive load) Refer to page 7, Engineering Data for details. 0.5 to 25 A at 40°C 0.5 to 35 A at 25°C 0.5 to 45 A at 25°C 440 A (60 Hz, 1 cycle) 260 A2s 1260 A2s Note: The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in, Engineering Data on page 7. 4 G3PB-2/-3 ■ Characteristics Models with Built-in Heat Sinks Item G3PB215B-3-VD G3PB215B-2-VD G3PB225B-3-VD G3PB225B-2-VD G3PB235B-3-VD G3PB235B-2-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.6 V (RMS) max. Leakage current (See note.) 10 mA (at 200 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (Mounted to DIN track) Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: Storage: Ambient humidity Operating: 45% to 85% Weight Approx. 750 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) (From April 1999) EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 G3PB415B-3-VD G3PB245B-2-VD Approx. 1,500 g Approx. 1,150 g –30°C to 80°C (with no icing or condensation) –30°C to 100°C (with no icing or condensation) Approx. 750 g Approx. 900 g Note: The leakage current of phase S will be approximately Item G3PB245B-3-VD G3PB415B-2-VD Approx. 750 g Approx. 1,150 g Approx. 900 g 3 times larger if the 2-element model is applied. G3PB425B-3-VD G3PB425B-2-VD G3PB435B-3-VD G3PB435B-2-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.8 V (RMS) max. Leakage current (See note.) 20 mA (at 400 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (Mounted to DIN track) Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: Storage: Ambient humidity Operating: 45% to 85% Weight Approx. 750 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 G3PB445B-3-VD G3PB445B-2-VD –30°C to 80°C (with no icing or condensation) –30°C to 100°C (with no icing or condensation) Approx. 750 g Approx. 900 g Note: The leakage current of phase S will be approximately Approx. 750 g Approx. 1,150 g Approx. 900 g Approx. 1,500 g Approx. 1,150 g 3 times larger if the 2-element model is applied. 5 G3PB-2/-3 Models without Built-in Heat Sinks Item G3PB215B3H-VD G3PB215B2H-VD G3PB225B3H-VD G3PB225B2H-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.6 V (RMS) max. Leakage current (See note.) 10 mA (at 200 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: Storage: Ambient humidity Operating: 45% to 85% Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) Weight (Max.) 300 g max. EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 G3PB235B2H-VD G3PB245B3H-VD G3PB245B2H-VD G3PB445B3H-VD G3PB445B2H-VD –30°C to 80°C (with no icing or condensation) –30°C to 100°C (with no icing or condensation) Note: The leakage current of phase S will be approximately Item G3PB235B3H-VD G3PB415B3H-VD G3PB415B2H-VD 3 times larger if the 2-element model is applied. G3PB425B3H-VD G3PB425B2H-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC input) Release time 1/2 of load power source cycle + 1 ms max. (DC input) Output ON voltage drop 1.8 V (RMS) max. Leakage current (See note.) 20 mA (at 400 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: Storage: Ambient humidity Operating: 45% to 85% Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3) Weight Approx. 300 g EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 G3PB435B3H-VD G3PB435B2H-VD –30°C to 80°C (with no icing or condensation) –30°C to 100°C (with no icing or condensation) Note: The leakage current of phase S will be approximately 3 times larger if the 2-element model is applied. Heat Sinks Model Weight Y92B-P50 Approx. 450 g Y92B-P100 Approx. 450 g Y92B-P150 Approx. 600 g Y92B-P200 Approx. 850 g Y92B-P250 Approx. 1,200 g 6 G3PB-2/-3 Engineering Data Load Current vs. Ambient Temperature Models with Built-in Heat Sinks G3PB-225B-3-VD G3PB-225B-2-VD Load current (A) 30 25 20 G3PB-235B-3-VD G3PB-235B-2-VD 30 Derating curve under UL standard 25 22 20 Load current (A) Load current (A) G3PB-215B-3-VD G3PB-215B-2-VD 50 Derating curve under UL standard 40 35 30 28 15 Derating curve under UL standard 20 10 8 10 7 6 10 8 0 −30 −20 14 20 0 0 -30 -20 40 60 80 100 Ambient temperature (°C) 0 20 25 40 60 80 0 −30 −20 100 0 20 25 Ambient temperature (°C) 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 28 A is applicable under the UL standard only with forced air cooling by fan. Derating curve under UL standard 45 42 40 G3PB-425B-3-VD G3PB-425B-2-VD 30 Load current (A) 50 G3PB-415B-3-VD G3PB-415B-2-VD Load current (A) Load current (A) G3PB-245B-3-VD G3PB-245B-2-VD 25 20 30 Derating curve under UL standard 25 22 20 30 Derating curve under UL standard 15 20 18 10 12 10 7 6 0 −30 −20 10 8 0 0 20 25 −30 −20 40 60 80 100 Ambient temperature (°C) 0 20 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 42 A is applicable under the UL standard only with forced air cooling by fan. 0 20 25 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 22 A is applicable under the UL standard only with forced air cooling by fan. G3PB-445B-3-VD G3PB-445B-2-VD 50 Derating curve under UL standard 40 35 Load current (A) Load current (A) G3PB-435B-3-VD G3PB-435B-2-VD 0 −30 −20 50 Derating curve under UL standard 45 42 40 30 28 30 20 20 18 14 12 10 10 8 0 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 28 A is applicable under the UL standard only with forced air cooling by fan. 0 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 42 A is applicable under the UL standard only with forced air cooling by fan. 7 G3PB-2/-3 Models without Built-in Heat Sinks G3PB-235B-3H-VD G3PB-235B-2H-VD G3PB-245B-3H-VD G3PB-245B-2H-VD G3PB-225B-3H-VD G3PB-225B-2H-VD G3PB-425B-3H-VD G3PB-425B-2H-VD Load current (A) Load current (A) G3PB-215B-3H-VD G3PB-215B-2H-VD G3PB-415B-3H-VD G3PB-415B-2H-VD 10 G3PB-225B-3(-2)H-VD G3PB-425B-3(-2)H-VD 8 Derating curve under UL standard 10 Derating curve under UL standard 8 6 6 5 5 4 4 2 G3PB-435B-3H-VD G3PB-435B-2H-VD G3PB-445B-3H-VD G3PB-445B-2H-VD G3PB-215B-3(-2)H-VD G3PB-415B-3(-2)H-VD 2 1.5 0 −30 −20 1.5 0 20 40 60 80 0 −30 −20 100 0 20 25 Ambient temperature (°C) 40 60 80 100 Ambient temperature (°C) Note: Please use proper ventilation and cooling. Note: Please use proper ventilation and cooling. Input impedance (kΩ) Input current (mA) Input Voltage vs. Input Current and Input Voltage vs. Input Impedance Input current Input impedance Input voltage (V) One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. G3PB-225B-3 (H)-VD G3PB-425B-3 (H)-VD G3PB-225B-2 (H)-VD G3PB-415B-3 (H)-VD G3PB-425B-2 (H)-VD G3PB-415B-2 (H)-VD Energized time (ms) G3PB-235B-3 (H)-VD G3PB-235B-2 (H)-VD G3PB-245B-3 (H)-VD G3PB-245B-2 (H)-VD G3PB-435B-3 (H)-VD G3PB-435B-2 (H)-VD G3PB-445B-3 (H)-VD G3PB-445B-2 (H)-VD Inrush current Inrush current Inrush current G3PB-215B-3 (H)-VD G3PB-215B-2 (H)-VD Energized time (ms) Energized time (ms) 8 G3PB-2/-3 Heat Sink Area vs. Load Current G3PB-425B-3H-VD Ambient temperature: 80°C Ambient temperature: 40°C Aluminum plate (t=3.0 mm) Heat sink area (cm2) Heat sink area (cm2) G3PB-225B-3H-VD Ambient temperature: 80°C Ambient temperature: 40°C Aluminum plate (t=3.0 mm) Load current (A) Load current (A) Note: The heat sink area refers to the combined area of the sides of the heat sink that radiate heat. In the case of G3PB-425B-3H-VD, when a current of 18 A is allowed to flow through the SSR at 40°C, the graph shows that the heat sink area is about 2,500 cm2. Therefore, if the heat sink is square, one side of the heat sink must be 36 cm (362 × 2 = 2,592) or longer. Thermal Resistance Rth (Junction/SSR Back Surface) Three-phase Models without Heat Sink Model Rth (°C/W) G3PB-215B-3H-VD 1.05 G3PB-225B-3H-VD 0.57 G3PB-235B-3H-VD 0.57 G3PB-245B-3H-VD 0.57 9 G3PB-2/-3 Dimensions Note: All units are in millimeters unless otherwise indicated. Models with Built-in Heat Sinks G3PB-215B-2-VD G3PB-415B-2-VD Without Terminal Cover With Terminal Cover 4.6 dia. 50 80.5 90 100 max. max. 24 Two, M3.5 × 8 Six, M4 × 12 0.5 20 20 80 max. Elliptical hole: 4.6 × 5.6 32.2 Mounting holes Two, 4.5 dia. or M4 30.5 14.6 19.4 max. 55 max. 90±0.3 Terminal Arrangement/Internal Circuit Diagram 50±0.3 G3PB-215B-2-VD L1/R L2/S G3PB-415B-2-VD (+) L3/T L1/R L2/S (+) L3/T Input circuit A1 Input circuit A1 A2 T1/U Without Terminal Cover T3/W A2 T1/U (−) T2/V T3/W (−) With Terminal Cover Four, R2.5 5 60 80.5 max. 24 Two, M3.5 × 8 0.5 20 80 max. 100 110.5 max. Six, M4 × 12 20 32.2 Mounting Holes 30.5 14.6 19.4 max. Four, 4.5 dia or M4 70 max. 60±0.3 100±0.3 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T (+) L1/R L2/S L3/T A1 T2/V T3/W (−) (+) L1/R L2/S G3PB-425B-2-VD L3/T A1 A2 T1/U T2/V T3/W (−) (+) L1/R L2/S L3/T A1 Input circuit A2 T1/U G3PB-415B-3-VD A1 A2 T1/U T2/V T3/W (−) (+) Input circuit L1/R G3PB-225B-2-VD Input circuit G3PB-215B-3-VD Input circuit G3PB-215B-3-VD G3PB-225B-2-VD G3PB-415B-3-VD G3PB-425B-2-VD T2/V A2 T1/U T2/V T3/W (−) 10 G3PB-2/-3 G3PB-225B-3-VD G3PB-235B-2-VD G3PB-425B-3-VD G3PB-435B-2-VD Without Terminal Cover With Terminal Cover 5 Four, R2.5 80.5 90 110.5 max. max. 24 Two, M3.5 × 8 0.5 20 Six, M5 × 12 (G3PB-@35B-2-VD) Six, M4 × 12 (G3PB-@25B-3-VD) 20 32.2 80 max. 100 110.5 max. Mounting Holes 30.5 14.6 19.4 max. Four, 4.5 dia or M4 70 max. 90±0.3 100±0.3 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T L1/R L2/S L3/T Input circuit T3/W (−) L3/T T2/V Without Terminal Cover T3/W (−) (+) L1/R L2/S L3/T A1 A2 T1/U T2/V T3/W (−) (+) A1 A2 T1/U A2 T1/U T2/V T3/W (−) With Terminal Cover 5 Four, R2.5 80.5 130.5 max. 90 max. 24 0.5 20 Two, Six, M3.5 × 8 M5 × 12 20 80 max. 120 130.5 max. 32.2 Mounting Holes 30.5 14.6 19.4 max. Four, 4.5 dia or M4 70 max. 90±0.3 120±0.3 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T (+) L1/R L2/S L3/T A1 T2/V T3/W (−) (+) L1/R L2/S G3PB-445B-2-VD L3/T A1 A2 T1/U T2/V T3/W (−) (+) L1/R L2/S L3/T A1 Input circuit A2 T1/U G3PB-435B-3-VD A1 A2 T1/U T2/V T3/W (−) (+) Input circuit L1/R G3PB-245B-2-VD Input circuit G3PB-235B-3-VD Input circuit G3PB-235B-3-VD G3PB-245B-2-VD G3PB-435B-3-VD G3PB-445B-2-VD T2/V L2/S A1 A2 T1/U L1/R G3PB-435B-2-VD Input circuit Input circuit A1 G3PB-425B-3-VD (+) Input circuit L1/R G3PB-235B-2-VD (+) Input circuit G3PB-225B-3-VD A2 T1/U T2/V T3/W (−) 11 G3PB-2/-3 Without Terminal Cover With Terminal Cover 5 Four, R2.5 80.5 150 190.5 max. max. 24 Two, M3.5 × 8 Six, M5 × 12 20 20 32.2 80 max. 120 130.5 max. Mounting Holes 30.5 14.6 19.4 max. Four, 4.5 dia or M4 70 max. 150±0.3 Terminal Arrangement/Internal Circuit Diagram G3PB-445B-3-VD G3PB-245B-3-VD L1/R L2/S L3/T (+) L1/R L2/S L3/T 120±0.3 A2 A2 T1/U T2/V T3/W (−) (+) A1 A1 Input circuit 0.5 Input circuit G3PB-245B-3-VD G3PB-445B-3-VD T1/U T2/V T3/W (−) 12 G3PB-2/-3 Models without Built-in Heat Sinks Without Terminal Cover G3PB-215B-3H-VD G3PB-215B-2H-VD G3PB-225B-3H-VD G3PB-225B-2H-VD G3PB-235B-3H-VD G3PB-235B-2H-VD G3PB-245B-3H-VD G3PB-245B-2H-VD G3PB-415B-3H-VD G3PB-415B-2H-VD G3PB-425B-3H-VD G3PB-425B-2H-VD G3PB-435B-3H-VD G3PB-435B-2H-VD G3PB-445B-3H-VD G3PB-445B-2H-VD Four, 8 dia. With Terminal Cover Four, 4.5 dia. 6 8 4 68 80.5 max. 24 Two, M3.5 × 8 0.5 20 80 max. 20 32.2 68 Six, M4 × 12 (G3PB-@15B@H-VD/-@25B-@H-VD) Six, M5 × 12 (G3PB-@35B-@H-VD/-@45B-@H-VD) Mounting Holes 30.5 14.6 19.4 max. Four, 4.5 dia or M4 68±0.3 68±0.3 Terminal Arrangement/Internal Circuit Diagram L2/S L3/T L1/R L2/S L3/T A1 T3/W (−) L1/R L2/S L3/T T2/V T3/W L1/R L2/S L3/T T1/U (−) T2/V T3/W (−) (+) A1 A2 A2 T1/U G3PB-4@5B-2H-VD (+) A1 Input circuit Input circuit T2/V (+) A1 A2 T1/U G3PB-4@5B-3H-VD G3PB-2@5B-2H-VD (+) Input circuit L1/R Input circuit G3PB-2@5B-3H-VD A2 T1/U T2/V T3/W (−) Heat Sinks Y92B-P50 For model Y92B-P100 For G3PB-215B-3H-VD G3PB-225B-2H-VD G3PB-415B-3H-VD G3PB-425B-2H-VD G3PB-215B-2H-VD G3PB-415B-2H-VD Four, M4 4.6 dia. Mounting Holes 100 Four, 4.5 dia. or M4 5 80.5 90 max. 100 max. 60 80.5 max. 68 60±0.3 100±0.3 Four, R2.5 Elliptical hole: 4.6 x 5.6 68 110.5 max. 80 max. Mounting Holes Two, 4.5 dia. or M4 55 max. 70 max. 13 G3PB-2/-3 Y92B-P250 For model G3PB-245B-3-VD G3PB-445B-3-VD Y92B-P200 For model G3PB-235B-3H-VD G3PB-245B-2H-VD G3PB-435B-3H-VD G3PB-445B-2H-VD Y92B-P150 For model G3PB-225B-3H-VD G3PB-235B-2H-VD G3PB-425B-3H-VD G3PB-435B-2H-VD 120 120 Four, M4 100 M4 Depth10 Four, M4 5 5 5 90 130.5 max. 68 90 110.5 max. 68 68 47.6 150 190.5 max. M4 Depth10 Four, R2.5 68 Four, R2.5 Four, M4 68 110.5 max. 120 130.5 max. Four, R2.5 68 120 130.5 max. 70 max. 70 max. Mounting Holes 70 max. Mounting Holes Mounting Holes Four, 4.5 dia. or M4 Four, 4.5 dia. or M4 Four, 4.5 dia. or M4 90±0.3 90±0.3 100±0.3 150±0.3 120±0.3 120±0.3 Accessories (Order Separately) Mounting Tracks PFP-100N, PFP-50N PFP-100N2 16 7.3±0.15 4.5 4.5 35±0.3 15 25 10 25 25 25 10 1,000 (500) (see note) 15 (5) (see note) 35±0.3 27 24 27±0.15 15 25 10 25 25 1,000 10 25 15 1 29.2 1.5 Note: Values in parentheses indicate dimensions for the PFP-50N. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 14 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.
G3PB445B3VDDC1224 价格&库存

很抱歉,暂时无法提供与“G3PB445B3VDDC1224”相匹配的价格&库存,您可以联系我们找货

免费人工找货