0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G3PB545B2NVDDC1224

G3PB545B2NVDDC1224

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Relay SSR 10mA 30V DC-IN 45A 528V AC-OUT 8-Pin

  • 数据手册
  • 价格&库存
G3PB545B2NVDDC1224 数据手册
Solid State Contactors (New Heat Sink Construction) G3PB-2N/-3N CSM_G3PB-2N_-3N_DS_E_2_1 Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications. • A comprehensive lineup that now includes 480-VAC models. • Slim design with 3-phase output and built-in heat sinks. • New heat sink construction with smaller mounting section. • DIN track mounting supported as standard. (Screw mounting is also possible.) • Certified by UL, CSA, and VDE. Refer to Safety Precautions for All Solid State Relays. Model Number Structure ■ Model Number Legend G3PB-@@@-@@-@ 1 2 3 4 5 6 7 1. Basic Model Name G3PB: Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 5: 480 VAC 3. Rated Load Current 15: 15 A 25: 25 A 35: 35 A 45: 45 A 4. Terminal Type B: Screw terminals 5. Single-phase/3-phase and Number of Elements for 3-phase 2: 3-phase, 2-element models 3: 3-phase, 3-element models 6. 3-phase Type N: DIN track mounting and built-in heat sink H: No heat sink (“hockey puck” type) 7. Certification VD: Certified by UL, CSA, and VDE 1 G3PB-2N/-3N Ordering Information ■ Solid State Contactors Models with Built-in Heat Sinks Applicable phase 3 Main circuit voltage 100 to 240 VAC Zero cross function Yes Applicable load current (with Class-1 AC resistive load) 15 A 25 A 35 A 45 A 200 to 480 VAC 15 A 25 A 35 A 45 A Number of poles Model 3 G3PB-215B-3N-VD DC12-24 2 G3PB-215B-2N-VD DC12-24 3 G3PB-225B-3N-VD DC12-24 2 G3PB-225B-2N-VD DC12-24 3 G3PB-235B-3N-VD DC12-24 2 G3PB-235B-2N-VD DC12-24 3 G3PB-245B-3N-VD DC12-24 2 G3PB-245B-2N-VD DC12-24 3 G3PB-515B-3N-VD DC12-24 2 G3PB-515B-2N-VD DC12-24 3 G3PB-525B-3N-VD DC12-24 2 G3PB-525B-2N-VD DC12-24 3 G3PB-535B-3N-VD DC12-24 2 G3PB-535B-2N-VD DC12-24 3 G3PB-545B-3N-VD DC12-24 2 G3PB-545B-2N-VD DC12-24 Note: The applicable load current depends on the ambient temperature. When ordering, specify the rated input voltage. Models with Externally Attached Heat Sinks Applicable phase 3 Main circuit voltage 100 to 240 VAC 200 to 480 VAC Zero cross function Yes Applicable load current (See note.) 15 A Number of poles 3 Model G3PB-215B-3H-VD DC12-24 2 G3PB-215B-2H-VD DC12-24 25 A 3 G3PB-225B-3H-VD DC12-24 2 G3PB-225B-2H-VD DC12-24 35 A 3 G3PB-235B-3H-VD DC12-24 2 G3PB-235B-2H-VD DC12-24 45 A 3 G3PB-245B-3H-VD DC12-24 2 G3PB-245B-2H-VD DC12-24 15 A 25 A 3 G3PB-515B-3H-VD DC12-24 2 G3PB-515B-2H-VD DC12-24 3 G3PB-525B-3H-VD DC12-24 2 G3PB-525B-2H-VD DC12-24 35 A 3 G3PB-535B-3H-VD DC12-24 2 G3PB-535B-2H-VD DC12-24 45 A 3 G3PB-545B-3H-VD DC12-24 2 G3PB-545B-2H-VD DC12-24 Note: The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. 2 G3PB-2N/-3N Specifications ■ Ratings (at an Ambient Temperature of 25°C) Operating Circuit (Common) Item Common Rated voltage 12 to 24 VDC Operating voltage range 9.6 to 30 VDC Rated input current (Impedance) 10 mA max. (at 24 VDC) Must operate voltage 9.6 VDC max. Must release voltage 1 VDC min. Insulation method Phototriac coupler Operation indicator Yellow LED Main Circuit of Models with Built-in Heat Sinks Model G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB- G3PB215B- 215B- 225B- 225B- 235B- 235B- 245B- 245B- 515B- 515B- 525B- 525B- 535B- 535B- 545B- 545B3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD 3N-VD 2N-VD Item Rated load voltage 100 to 240 VAC 200 to 480 VAC Load voltage range 75 to 264 VAC 180 to 528 VAC Applicable load current (See note 1.) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) Minimum load cur- 0.2 A rent 0.5 A Inrush current resistance (peak value) 150 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) Permissible I2t (half 60-Hz wave) 121 A2s 260 A2s 1260 A2s 260 A2s 1260 A2s Applicable load (resistive load, AC1) (See note 2.) 5.1 kW max. (at 200 VAC) 8.6 kW max. (at 200 VAC) 12.1 kW max. 15.5 kW max. 12.5 kW max. 20.7 kW max. 29.0 kW max. 37.4 kW max. (at 200 VAC) (at 200 VAC) (at 480 VAC) (at 480 VAC) (at 480 VAC) (at 480 VAC) Note: 1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. 2. Applicable Load Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections. Maximum load capacity = Load current × Load voltage × 3 Example: 15 A × 200 V × 3 = 5.196 W ≅ 5.1 kW Example: 15 A × 400 V × 3 = 10.392 W ≅ 10.3 kW Main Circuit of Models with Externally Attached Heat Sinks Model G3PB Item G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB -215B -215B -225B -225B -235B -235B -245B -245B -515B -515B -525B -525B -535B -535B -545B -545B -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD Rated load voltage 100 to 240 VAC 200 to 480 VAC Load voltage range 75 to 264 VAC 180 to 528 VAC Applicable load current (See note.) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) Minimum load 0.2 A current Inrush current resistance (peak value) 0.5 A 150 A (60 Hz, 220 A (60 Hz, 440 A (60 Hz, 1 cycle) 1 cycle) 1 cycle) Permissible 121 A2s I2t (half 60-Hz wave) 260 A2s 1,260 A2s 220 A (60 Hz, 1 cycle) 440 A (60 Hz, 1 cycle) 260 A2s 1,260 A2s Applicable Refer to Engineering Data on page 5. load (resistive load, AC1) Note: The applicable load current depends on the heat sink that is connected and the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5. 3 G3PB-2N/-3N ■ Characteristics Models with Built-in Heat Sinks Item G3PB215B3N-VD G3PB215B2N-VD G3PB225B3N-VD G3PB225B2N-VD G3PB235B3N-VD G3PB235B2N-VD G3PB245B3N-VD G3PB245B2N-VD G3PB515B3N-VD G3PB515B2N-VD G3PB525B3N-VD G3PB525B2N-VD G3PB535B3N-VD G3PB535B2N-VD G3PB545B3N-VD G3PB545B2N-VD Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current (See note.) 10 mA (at 200 VAC) 20 mA (at 480 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) (Mounted to DIN track) Shock resistance Destruction: 294 m/s2 (98 m/s2 with reverse mounting) Ambient operating temperature Operating: –30°C to 80°C (with no icing or condensation) Storage: –30°C to 100°C (with no icing or condensation) Ambient operating humidity Operating: 45% to 85% Weight Approx. 1.25 kg Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE (From April 2001) EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Approx. 1.45 kg Approx. 1.25 kg Approx. 1.65 kg ApApprox. prox. 2.0 kg 1.65 kg Approx. 1.45 kg Note: The leakage current of phase S will be approximately Approx. 1.25 kg Approx. 1.45 kg Approx. 1.25 kg Approx. 1.65 kg Approx. 1.45 kg ApApprox. prox. 2.0 kg 1.65 kg 3 times larger if the 2-element model is applied. Models with Externally Attached Heat Sinks Model G3PB Item G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB G3PB -215B -215B -225B -225B -235B -235B -245B -245B -515B -515B -525B -525B -535B -535B -545B -545B -3H-VD -2H-VD -3H-VD -2HVD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD -3H-VD -2H-VD Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. 1.8 V (RMS) max. Leakage current (See note.) 10 mA (at 200 VAC) 20 mA (at 480 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) Shock resistance Destruction: 294 m/s2 (98 m/s2 with reverse mounting) Storage temperature –30°C to 100°C (with no icing or condensation) Ambient operating temperature –30°C to 80°C (with no icing or condensation) Ambient storage humidity 45% to 85% Weight Approx. 300 g Note: The leakage current of phase S will be approximately 3 times larger if the 2-element model is used. 4 G3PB-2N/-3N Engineering Data Load Current vs. Ambient Temperature Models with Built-in Heat Sinks G3PB-225B-3N-VD G3PB-225B-2N-VD Load current (A) 30 25 20 G3PB-235B-3N-VD G3PB-235B-2N-VD 30 Derating curve under UL standard 25 22 20 Load current (A) Load current (A) G3PB-215B-3N-VD G3PB-215B-2N-VD 50 Derating curve under UL standard 40 35 30 28 15 Derating curve under UL standard 20 10 8 10 7 6 10 8 0 −30 −20 14 20 0 0 -30 -20 40 60 80 100 Ambient temperature (°C) 0 20 25 40 60 80 100 0 −30 −20 0 20 25 Ambient temperature (°C) 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 28 A is applicable under the UL standard only with forced air cooling by fan. Derating curve under UL standard 45 42 40 G3PB-525B-3N-VD G3PB-525B-2N-VD 30 Load current (A) 50 G3PB-515B-3N-VD G3PB-515B-2N-VD Load current (A) Load current (A) G3PB-245B-3N-VD G3PB-245B-2N-VD 25 20 30 30 Derating curve under UL standard 25 22 20 15 Derating curve under UL standard 20 18 10 12 10 0 −30 −20 10 8 7 6 0 0 20 25 40 60 80 100 Ambient temperature (°C) −30 −20 0 20 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 42 A is applicable under the UL standard only with forced air cooling by fan. 20 25 40 60 80 100 Ambient temperature (°C) G3PB-545B-3N-VD G3PB-545B-2N-VD 50 Derating curve under UL standard 40 35 50 30 20 20 18 14 Derating curve under UL standard 45 42 40 30 28 12 10 10 8 0 −30 −20 0 Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 22 A is applicable under the UL standard only with forced air cooling by fan. Load current (A) Load current (A) G3PB-535B-3N-VD G3PB-535B-2N-VD 0 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 28 A is applicable under the UL standard only with forced air cooling by fan. 0 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) Note: 1. Please use proper ventilation and cooling. 2. Please note that the derating curve above 42 A is applicable under the UL standard only with forced air cooling by fan. 5 G3PB-2N/-3N Load Current vs. Ambient Temperature Models without Built-in Heat Sinks G3PB-235B-3H(-2H)-VD G3PB-245B-3H(-2H)-VD G3PB-535B-3H(-2H)-VD G3PB-545B-3H(-2H)-VD 10 G3PB-225B-3(-2)H-VD G3PB-525B-3(-2)H-VD 8 Derating curve under UL standard Load current (A) Load current (A) G3PB-215B-3H(-2H)-VD G3PB-225B-3H(-2H)-VD G3PB-515B-3H(-2H)-VD G3PB-525B-3H(-2H)-VD 10 Derating curve under UL standard 8 6 6 5 5 4 4 G3PB-215B-3(-2)H-VD G3PB-515B-3(-2)H-VD 2 2 1.5 1.5 0 −30 −20 0 20 0 −30 −20 40 60 80 100 Ambient temperature (°C) Note: Please use proper ventilation and cooling. 0 20 25 40 60 80 100 Ambient temperature (°C) Note: Please use proper ventilation and cooling. Input impedance (kΩ) Input current (mA) Input Voltage vs. Input Current and Input Voltage vs. Input Impedance Input current Input impedance Input voltage (V) One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. G3PB-225B-3N/3H-VD G3PB-225B-2N/2H-VD G3PB-515B-3N/3H-VD G3PB-515B-2N/2H-VD G3PB-525B-3N/3H-VD G3PB-525B-2N/2H-VD G3PB-235B-3N/3H-VD G3PB-235B-2N/2H-VD G3PB-245B-3N/3H-VD G3PB-245B-2N/2H-VD G3PB-535B-3N/3H-VD G3PB-535B-2N/2H-VD G3PB-545B-3N/3H-VD G3PB-545B-2N/2H-VD Energized time (ms) Inrush current Inrush current Inrush current G3PB-215B-3N/3H-VD G3PB-215B-2N/2H-VD Energized time (ms) Energized time (ms) 6 G3PB-2N/-3N Dimensions Note: All units are in millimeters unless otherwise indicated. G3PB-215B-3N-VD G3PB-215B-2N-VD G3PB-225B-2N-VD G3PB-515B-3N-VD G3PB-515B-2N-VD G3PB-525B-2N-VD Without Terminal Cover With Terminal Cover Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 24 80.5 90 max. 68 100 max. Two, R2.3 mounting holes 0.5 20 64 20 32.2 80 max. Six, M4 68 Mounting Hole Dimensions 30.5 14.6 19.4 max. 64±0.3 90±0.3 120 max. Four, 4.5-dia. or M4 Terminal Arrangement/Internal Connections L2/S (+) L3/T L1/R L2/S A1 T3/W L2/S L3/T G3PB-5@5B-2N-VD (+) T2/V Without Terminal Cover T3/W (−) L2/S L3/T T1/U T2/V T3/W (−) (+) A1 A2 A2 T1/U (−) L1/R A1 Input circuit Input circuit G3PB-225B-3N-VD G3PB-235B-2N-VD G3PB-525B-3N-VD G3PB-535B-2N-VD T2/V L1/R A1 A2 T1/U G3PB-515B-3N-VD (+) L3/T Input circuit L1/R G3PB-2@5B-2N-VD Input circuit G3PB-215B-3N-VD A2 T1/U T2/V T3/W (−) With Terminal Cover Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 24 80.5 120 100 110 max. max. 68 Two, R2.3 mounting holes 0.5 20 32.2 20 64 Six, M5 (35 A type) Six, M4 (25 A type) 80 max. 68 Mounting Hole Dimensions 30.5 14.6 19.4 max. 64±0.3 110±0.3 120 max. Four, 4.5-dia. or M4 Terminal Arrangement/Internal Connections L2/S L3/T L1/R L2/S L3/T A1 T3/W (−) L1/R L2/S L3/T T2/V T3/W (−) L1/R L2/S L3/T T1/U T2/V T3/W (−) (+) A1 A2 A2 T1/U G3PB-535B-2N-VD (+) A1 Input circuit Input circuit T2/V (+) A1 A2 T1/U G3PB-525B-3N-VD G3PB-235B-2N-VD (+) Input circuit L1/R Input circuit G3PB-225B-3N-VD A2 T1/U T2/V T3/W (−) 7 G3PB-2N/-3N G3PB-235B-3N-VD G3PB-245B-2N-VD G3PB-535B-3N-VD G3PB-545B-2N-VD Without Terminal Cover With Terminal Cover Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 80.5 140 120 130 max. max. 68 24 Two, R2.3 mounting holes 0.5 Six, M5 20 64 80 max. 20 32.2 68 Mounting Hole Dimensions 30.5 14.6 19.4 max. 64±0.3 120 max. 130±0.3 Four, 4.5-dia. or M4 Terminal Arrangement/Internal Connections L2/S L3/T L1/R L2/S L3/T A1 T3/W L2/S L3/T Without Terminal Cover T2/V T3/W (−) L1/R L2/S L3/T T1/U T2/V T3/W (+) A1 A2 A2 T1/U (−) (+) A1 Input circuit Input circuit G3PB-245B-3N-VD G3PB-545B-3N-VD T2/V L1/R G3PB-545B-2N-VD A1 A2 T1/U (+) Input circuit L1/R G3PB-535B-3N-VD G3PB-245B-2N-VD (+) Input circuit G3PB-235B-3N-VD A2 T1/U (−) T2/V T3/W (−) With Terminal Cover Two, 4.6-dia. mounting holes Four, 8 dia. Two, M3.5 24 Two, R2.3 mounting holes Six, M5 0.5 20 80.5 140 120 130 max. max. 68 20 32.2 68 64 80 max. 110 max. Mounting Hole Dimensions 30.5 14.6 19.4 max. 64±0.3 120 max. 130±0.3 Terminal Arrangement/Internal Connections G3PB-545B-3N-VD G3PB-245B-3N-VD L1/R L2/S L3/T (+) L1/R L2/S L3/T Input circuit A2 A2 T1/U T2/V T3/W (−) (+) A1 A1 Input circuit Four, 4.5-dia. or M4 T1/U T2/V T3/W (−) 8 G3PB-2N/-3N ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 9 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.
G3PB545B2NVDDC1224 价格&库存

很抱歉,暂时无法提供与“G3PB545B2NVDDC1224”相匹配的价格&库存,您可以联系我们找货

免费人工找货