G3VM-351H(TR)

G3VM-351H(TR)

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    SOP6

  • 描述:

    RELAY SSR SPST 110MA 6-SOP

  • 数据手册
  • 价格&库存
G3VM-351H(TR) 数据手册
G3VM-351H MOS FET Relays MOS FET Relays Designed for Switching Minute Signals and Analog Signals. • Upgraded G3VM-S3 Series. • Continuous load current of 110 mA. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections 6 • Semiconductor test equipment 5 4 • Test & Measurement equipment OMRON logo • Communication equipment Model name 932 Pin 1 mark LOT.No. • Data loggers 1 3 2 Note: The actual product is marked differently from the image shown here. ■ List of Models Package type Contact form SOP6 1a (SPST-NO) Load voltage (peak value) * Terminals Surface-mounting Terminals 350 V Model Minimum package quantity Number per tube Number per tape and reel G3VM-351H G3VM-351H (TR) 75 - - 2,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Connection A Continuous Connection B load current Connection C Connection A ON current Connection B reduction rate Connection C Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF ∆IF/°C VR TJ VOFF Rating 50 −0.5 5 125 350 110 110 220 −1.1 −1.1 −2.2 125 Unit mA mA/°C V °C V VI-O 1500 Vrms Ta Tstg −40 to +85 −55 to +125 °C °C IO ∆IO/°C TJ - 260 Measurement conditions Ta ≥ 25°C Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Connection Diagram Connection A mA mA/°C Connection A: AC peak/DC Connection B and C: DC Ta ≥ 25°C Connection B °C °C 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 Input Output 1 Load DC AC for 1 min With no icing or condensation With no icing or condensation Connection C 10 s ■ Electrical Characteristics (Ta = 25°C) Item Symbol Minimum Typical Maximum LED forward voltage VF 1.0 1.15 1.3 Reverse current IR 10 Capacity between terminals CT 30 Trigger LED forward current IFT 1 3 25 35 Maximum Connection A 35 50 resistance RON with output Connection B 28 40 ON Connection C 14 20 Current leakage when the relay is open ILEAK 1.0 Capacity between terminals COFF 30 Capacity between I/O terminals CI-O 0.8 Insulation resistance between I/O terminals RI-O 1000 Turn-ON time tON 0.3 1.0 Turn-OFF time tOFF 0.1 1.0 Load or AC DC Unit V µA pF mA Ω Ω Ω Ω µA pF pF MΩ ms ms Measurement conditions IF = 10 mA VR = 5 V V = 0, f = 1 MHz IO = 110 mA Note: 2. Turn-ON and Turn-OFF Times IF = 5 mA, IO = 110 mA, t < 1 s IF 1 6 RL VDD IF = 5 mA, IO = 110 mA VOUT 2 4 IF = 5 mA, IO = 110 mA IF = 5 mA, IO = 220 mA VOFF = 350 V V = 0, f = 1 MHz IF f = 1 MHz, Vs = 0 V VI-O = 500 VDC, ROH ≤ 60 % IF = 5 mA, RL = 200 Ω, VDD = 20 V (See note 2.) VOUT 10% t ON 90% t OFF Load DC G3VM-351H MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature VDD IF IO Ta 5 −20 10 - 280 25 100 65 V mA mA °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 100 80 60 40 20 Connection C 200 160 120 Connection A and B -20 0 20 40 60 80 100 0.1 -20 0 20 40 60 80 100 120 On-state resistance vs. Ambient temperature IO = 120 mA IF = 5 mA t < 1s Connection A 40 30 20 0 -200 2 1 0 20 40 60 80 100 Turn ON, Turn OFF time vs. Ambient temperature tON, tOFF - IF 300 tOFF 30 tON 3 10 3 2 1 -20 0 20 VDD = 20 V RL = 200 Ω IF = 5 mA tON 400 300 200 100 30 100 300 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Ambient temperature ILEAK - Ta 500 tOFF 30 VOFF = 350 V IF = 5 mA 10 5 1 10 1 4 -40 Current leakage ILEAK (nA) Turn ON, Turn OFF time tON, tOFF (µs) 1000 1.8 IO = 120 mA t < 1s tON, tOFF - Ta Ta = 25°C VDD = 20 V RL = 200 Ω 1.6 5 Ambient temperature Ta (°C) On-state voltage VON (V) 3000 1.4 0 -20 3 Turn ON, Turn OFF time vs. LED forward current 1.2 IFT - Ta 50 10 100 1 LED forward voltage VF (V) Trigger LED forward current IFT (mA) 0 0 0.8 Trigger LED forward current vs. Ambient temperature -100 Turn ON, Turn OFF time tON, tOFF (µs) 0.6 Ambient temperature Ta (°C) On-state resistance RON (Ω) 100 -1 3 RON - Ta Ta = 25°C IF = 5 mA Connection A -2 10 0.3 IO - VON -3 30 40 120 200 -4 Ta = 25°C 1 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage 100 80 0 0 Continuous load current IO (mA) IF - VF 240 LED forward current IF (mA) Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 0.5 0 -40 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (°C) -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions SOP6 type ■ Appearance SOP (Small Outline Package) SOP6 OMRON logo Model name 932 Pin 1 mark LOT.No. Note: The actual product is marked differently from the image shown here. ■ Dimensions (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.13 g 4.4±0.25 (Recommended Value, TOP VIEW) 2.1 max. 6.3±0.25 6 to 6.3 1.2 0.15 0.8 2.54±0.25 0.1±0.1 0.4±0.1 Note: The actual product is marked differently from the image shown here. 0.6±0.3 7.0±0.4 2.54 2.54 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K166-E1-01 0412(0412)(O)
G3VM-351H(TR) 价格&库存

很抱歉,暂时无法提供与“G3VM-351H(TR)”相匹配的价格&库存,您可以联系我们找货

免费人工找货