G3VM-351H
MOS FET Relays
MOS FET Relays Designed for Switching
Minute Signals and Analog Signals.
• Upgraded G3VM-S3 Series.
• Continuous load current of 110 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
6
• Semiconductor test equipment
5
4
• Test & Measurement equipment
OMRON logo
• Communication equipment
Model name
932
Pin 1 mark
LOT.No.
• Data loggers
1
3
2
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
SOP6
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting Terminals
350 V
Model
Minimum package quantity
Number per tube Number per tape and reel
G3VM-351H
G3VM-351H (TR)
75
-
-
2,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
Continuous
Connection B
load current
Connection C
Connection A
ON current
Connection B
reduction
rate
Connection C
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
Rating
50
−0.5
5
125
350
110
110
220
−1.1
−1.1
−2.2
125
Unit
mA
mA/°C
V
°C
V
VI-O
1500
Vrms
Ta
Tstg
−40 to +85
−55 to +125
°C
°C
IO
∆IO/°C
TJ
-
260
Measurement conditions
Ta ≥ 25°C
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
Connection Diagram
Connection A
mA
mA/°C
Connection A: AC peak/DC
Connection B and C: DC
Ta ≥ 25°C
Connection B
°C
°C
1
6
2
5
3
4
1
6
2
5
3
4
1
6
2
5
3
4
Input
Output
1
Load
DC
AC for 1 min
With no icing or condensation
With no icing or condensation
Connection C
10 s
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFT
1
3
25
35
Maximum
Connection A
35
50
resistance
RON
with output
Connection B
28
40
ON
Connection C
14
20
Current leakage when the relay is open
ILEAK
1.0
Capacity between terminals COFF
30
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.3
1.0
Turn-OFF time
tOFF
0.1
1.0
Load
or AC
DC
Unit
V
µA
pF
mA
Ω
Ω
Ω
Ω
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 110 mA
Note: 2. Turn-ON and Turn-OFF Times
IF = 5 mA, IO = 110 mA, t < 1 s
IF 1
6 RL
VDD
IF = 5 mA, IO = 110 mA
VOUT
2
4
IF = 5 mA, IO = 110 mA
IF = 5 mA, IO = 220 mA
VOFF = 350 V
V = 0, f = 1 MHz
IF
f = 1 MHz, Vs = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
IF = 5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
VOUT
10%
t ON
90%
t OFF
Load
DC
G3VM-351H
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
IO
Ta
5
−20
10
-
280
25
100
65
V
mA
mA
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
IO - Ta
100
80
60
40
20
Connection C
200
160
120
Connection A and B
-20
0
20
40
60
80
100
0.1
-20
0
20
40
60
80
100
120
On-state resistance vs. Ambient
temperature
IO = 120 mA
IF = 5 mA
t < 1s
Connection A
40
30
20
0
-200
2
1
0
20
40
60
80
100
Turn ON, Turn OFF time vs. Ambient
temperature
tON, tOFF - IF
300
tOFF
30
tON
3
10
3
2
1
-20
0
20
VDD = 20 V
RL = 200 Ω
IF = 5 mA
tON
400
300
200
100
30
100
300
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Ambient
temperature
ILEAK - Ta
500
tOFF
30
VOFF = 350 V
IF = 5 mA
10
5
1
10
1
4
-40
Current leakage ILEAK (nA)
Turn ON, Turn OFF time tON, tOFF (µs)
1000
1.8
IO = 120 mA
t < 1s
tON, tOFF - Ta
Ta = 25°C
VDD = 20 V
RL = 200 Ω
1.6
5
Ambient temperature Ta (°C)
On-state voltage VON (V)
3000
1.4
0
-20
3
Turn ON, Turn OFF time vs. LED
forward current
1.2
IFT - Ta
50
10
100
1
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
0
0
0.8
Trigger LED forward current vs.
Ambient temperature
-100
Turn ON, Turn OFF time tON, tOFF (µs)
0.6
Ambient temperature Ta (°C)
On-state resistance RON (Ω)
100
-1
3
RON - Ta
Ta = 25°C
IF = 5 mA
Connection A
-2
10
0.3
IO - VON
-3
30
40
120
200
-4
Ta = 25°C
1
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
100
80
0
0
Continuous load current IO (mA)
IF - VF
240
LED forward current IF (mA)
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
0.5
0
-40
-20
LED forward current IF (mA)
0
20
40
60
80
100
Ambient temperature Ta (°C)
-40
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP6 type
■ Appearance
SOP (Small Outline Package)
SOP6
OMRON logo
Model name
932
Pin 1 mark
LOT.No.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.13 g
4.4±0.25
(Recommended Value, TOP VIEW)
2.1 max.
6.3±0.25
6 to 6.3
1.2
0.15
0.8
2.54±0.25
0.1±0.1
0.4±0.1
Note: The actual product is marked differently from the image shown here.
0.6±0.3
7.0±0.4
2.54
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K166-E1-01
0412(0412)(O)