0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G3VM-402J

G3VM-402J

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    SOP8

  • 描述:

    Solid State Relay DPST (2 Form A) 8-SOP (0.173", 4.40mm)

  • 数据手册
  • 价格&库存
G3VM-402J 数据手册
G3VM-402J MOS FET Relays MOS FET Relays Designed for Switching Minute Signals and Analog Signals. Two Channels and an 8-pin SOP Package in 400-V Load Voltage Series. • Continuous load current of 120 mA. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections • Semiconductor test equipment • Test & Measurement equipment 8 7 6 5 • Communication equipment OMRON logo • Data loggers Pin 1 mark 1 2 3 Model name LOT.No. 932 4 Note: The actual product is marked differently from the image shown here. ■ List of Models Package type Contact form SOP8 2a (DPST-NO) Load voltage (peak value) * Terminals Surface-mounting Terminals 400 V Model G3VM-402J G3VM-402J (TR) Minimum package quantity Number per tube Number per tape and reel 50 - - 2,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Continuous load current (AC peak/DC) ON current reduction rate Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF IFP ∆IF/°C VR TJ VOFF IO ∆IO/°C Rating 50 1 −0.5 5 125 400 120 −1.2 Unit mA A mA/°C V °C V mA mA/°C VI-O 1500 Vrms Ta Tstg - −40 to +85 −55 to +125 260 °C °C °C Measurement conditions 100 µs pulses, 100 pps Ta ≥ 25°C Ta ≥ 25°C AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Output Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.0 1.15 1.3 Reverse current IR 10 Capacity between terminals CT 30 Trigger LED forward current IFT 1 3 Maximum resistance with output ON RON 17 35 Current leakage when the relay is open ILEAK 1.0 Capacity between terminals COFF 70 Capacity between I/O terminals CI-O 0.8 Insulation resistance between I/O terminals RI-O 1000 Turn-ON time tON 0.3 1 Turn-OFF time tOFF 0.1 1 1 Unit V µA pF mA Ω µA pF pF MΩ ms ms Measurement conditions Note: 2. Turn-ON and Turn-OFF Times IF = 10 mA IF (3) 1 VR = 5 V 8 (6) RL VDD V = 0, f = 1 MHz VOUT (4) 2 7 (5) IO = 120 mA IF = 5 mA, IO = 120 mA VOFF = 400 V V = 0, f = 1 MHz IF f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH ≤ 60 % 90% VOUT 10% IF = 5 mA, RL = 200 Ω, t ON t OFF VDD = 20 V (See note 2.) G3VM-402J MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Load voltage (AC peak/DC) VDD - - 320 Unit V Operating LED forward current IF 5 7.5 25 mA Continuous load current (AC peak/DC) IO - - 120 mA Ambient operating temperature Ta −20 - 65 °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature 80 60 40 IF - VF LED forward current IF (mA) IO - Ta 100 Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 280 240 200 160 120 50 30 10 5 3 1 0.5 0.3 40 0 -20 0 20 40 60 80 100 0.1 0 120 -20 0 20 40 Continuous load current vs. On-state voltage 60 80 100 0.6 120 On-state resistance vs. Ambient temperature On-state resistance RON (Ω) 100 0 IO = 120 mA IF = 5 mA 50 40 30 -100 10 0 -200 1 2 -20 3 0 20 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current tON, tOFF - IF Turn ON, Turn OFF time tON, tOFF (µs) 500 300 100 tOFF 50 1.8 80 IO = 120 mA t < 1s 4 3 2 1 0 100 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Ambient temperature tON, tOFF - Ta Ta = 25°C VDD = 20 V, RL = 200 Ω tON 60 Turn ON, Turn OFF time vs. Ambient temperature 2000 1000 40 1.6 5 Ambient temperature Ta (°C) ILEAK - Ta 1000 Current leakage ILEAK (nA) 0 1.4 IFT - Ta 60 20 -1 1.2 Trigger LED forward current vs. Ambient temperature RON - Ta Ta = 25°C IF = 5 mA -2 1 LED forward voltage VF (V) Trigger LED forward current IFT (mA) IO - VON 200 -3 0.8 Ambient temperature Ta (°C) Ambient temperature Ta (°C) Continuous load current IO (mA) Ta = 25°C 80 20 Turn ON, Turn OFF time tON, tOFF (µs) 100 VDD = 20 V, RL = 200 Ω IF = 5 mA 800 tON 600 400 1000 VOFF = 400 V 500 300 100 50 30 10 5 tOFF 200 3 30 1 3 5 10 30 50 100 LED forward current IF (mA) 0 -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) 1 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions SOP8 type ■ Appearance SOP (Small Outline Package) SOP8 OMRON logo Pin 1 mark 932 Model name LOT.No. Note: The actual product is marked differently from the image shown here. ■ SOP8 (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.2 g (Recommended Value, TOP VIEW) 4.4±0.2 2.1 max. 9.4±0.25 6 to 6.3 1.2 0.15 0.8 2.54±0.25 0.1±0.1 0.4±0.1 0.5±0.3 7.0±0.4 2.54 2.54 Note: The actual product is marked differently from the image shown here. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K170-E1-01 0412(0412)(O)
G3VM-402J 价格&库存

很抱歉,暂时无法提供与“G3VM-402J”相匹配的价格&库存,您可以联系我们找货

免费人工找货