MOS FET Relays
G3VM-402C/F
New Expanded Range of Analogswitching MOS FET Relays with 400-V
Load Voltage with 2 Output Channels.
• A 2-channel Relay now included in the 400-V load voltage
series.
• Continuous load current of 120 mA.
• Dielectric strength of 2,500 Vrms between I/O.
■ Application Examples
Approval pending
Note:
• Measurement devices
The actual product is marked differently from the image
shown here.
• Security systems
• Amusement machines
■ List of Models
Contact form
DPST-NO
Terminals
PCB terminals
Load voltage (peak value)
400 VAC
Surface-mounting
terminals
Model
G3VM-402C
Number per stick
Number per tape
50
---
---
1,500
G3VM-402F
G3VM-402F(TR)
■ Dimensions
Note:
All units are in millimeters unless otherwise indicated.
■ Terminal Arrangement/Internal Connections (Top View)
■ PCB Dimensions (Bottom View)
46
■ Actual Mounting Pad Dimensions
(Recommended Value, Top View)
G3VM-402C/F
G3VM-402C/F
■ Absolute Maximum Ratings (Ta = 25°C)
Item
Input
Symbol
Rating
Unit
Measurement Conditions
Note:
LED forward current
IF
50
mA
Repetitive peak LED forward
current
IFP
1
A
100 ms pulses, 100 pps
LED forward current reduction
rate
D IF/°C
-0.5
mA/°C
Ta ³ 25°C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
Output dielectric strength
VOFF
400
V
Continuous load current
IO
120
mA
ON current reduction rate
D ION/°C
-1.2
mA/°C
Connection temperature
Tj
125
°C
Dielectric strength between input and
output (See note 1.)
VI-O
2,500
Vrms
AC for 1 min
Operating temperature
Ta
-40 to +85
°C
With no icing or condensation
Storage temperature
Tstg
-55 to +125
°C
With no icing or condensation
Soldering temperature (10 s)
---
260
°C
10 s
Output
1. The dielectric strength between the input and
output was checked by applying voltage between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Ta ³ 25°C
■ Electrical Characteristics (Ta = 25°C)
Item
Input
Symbol
Minimum
Typical
Maximum
Unit
Measurement
conditions
Note:
LED forward voltage
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
mA
VR = 5 V
Capacity between terminals
CT
---
30
---
pF
V = 0, f = 1 MHz
Trigger LED forward current
IFT
---
1
3
mA
IO = 120 mA
Maximum resistance with output ON
RON
---
18
35
W
IF = 5 mA,
IO = 120 mA
Current leakage when the relay is
open
ILEAK
---
---
1.0
mA
VOFF = 400 V
Capacity between I/O terminals
CI-O
---
0.8
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance
RI-O
1,000
---
---
MW
VI-O = 500 VDC,
RoH £ 60%
Output
Turn-ON time
tON
---
---
1.0
ms
Turn-OFF time
tOFF
---
---
1.0
ms
2. Turn-ON and Turn-OFF
Times
IF
1
8
2
7
RL
VDD
VOUT
IF
IF = 5 mA, RL = 200 W,
VDD = 20 V (See note 2.)
VOUT
10%
t ON
90%
t OFF
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Output dielectric strength
VDD
---
---
Operating LED forward current
IF
5
Continuous load current
IO
---
Operating temperature
Ta
- 20
---
Maximum
Unit
320
V
7.5
25
mA
---
100
mA
65
°C
■ Engineering Data
■ Safety Precautions
Load Current vs. Ambient Temperature
Refer to page 6 for precautions common to all G3VM models.
Load current (mA)
G3VM-402C(F)
140
120
100
80
60
40
20
0
−20
0
20
40
60
80
100
Ambient temperature (°C)
47