G3VM-61LR
MOS FET Relays
World’s Smallest * SSOP Package MOS
FET Relays (COFF (typical): 20 pF, RON
(typical): 1 Ω) with Low Output
Capacitance and ON Resistance (C × R =
20 pF • Ω) in a 60-V Load Voltage Model.
• ON resistance of 1 Ω (typical) suppresses output signal attenuation.
Note: The actual product is marked differently from the
image shown here.
* As of March 2011 Survey by OMRON
RoHS compliant
■ Application Examples
■ Terminal Arrangement/Internal Connections
• Semiconductor test equipment
416
• Test & Measurement equipment
Model name
OMRON mark
• Communication equipment
LOT.No.
612
• Data loggers
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type
Contact form
Load voltage
(peak value) *
Terminals
Model
Minimum package quantity
Number per tape and reel
G3VM-61LR
SSOP4
1a
(SPST-NO)
Surface-mounting Terminals
60 V
G3VM-61LR (TR05)
G3VM-61LR (TR)
500
1,500
Note: Ask your OMRON representative for orders under 1,500 pcs or 500 pcs. We can supply products with the tape already cut.
Tape-cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them.
Refer to common precautions.
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25 °C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
Rating
50
−0.5
5
125
60
400
−4.0
125
Unit
mA
mA/°C
V
°C
V
mA
mA/°C
°C
VI-O
1500
Vrms
Ta
Tstg
-
−20 to +85
−40 to +125
260
°C
°C
°C
Measurement conditions
Ta ≥ 25 °C
Ta ≥ 25 °C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25 °C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
15
Trigger LED forward current
IFT
2
5
Maximum resistance with output ON
RON
1.0
1.5
Current leakage when the relay is open
ILEAK
1
Capacity between terminals COFF
20
30
Capacity between I/O terminals
CI-O
0.3
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.3
1
Turn-OFF time
tOFF
0.2
1
1
Unit
V
µA
pF
mA
Ω
µA
pF
pF
MΩ
ms
ms
Measurement conditions
Note: 2. Turn-ON and Turn-OFF Times
IF = 10 mA
IF 1
VR = 5 V
4 RL
VDD
V = 0, f = 1 MHz
VOUT
2
3
IO = 100 mA, RON < 1.5 Ω
IF = 5 mA, IO = 400 mA
VOFF = 60 V, Ta = 25 °C
V = 0, f = 100 MHz, t < 1 s
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 20 V (See note 2.)
G3VM-61LR
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
IO
Ta
10
−20
-
48
20
400
70
V
mA
mA
°C
■ Engineering Data
IO - Ta
100
80
60
40
20
400
300
200
20
40
60
80
100
Continuous load current vs. On-state voltage
0
20
40
200
100
0
-100
1.8
1.6
1
0.6
120
0.8
1
1.2
IO = 400 mA
IF = 5 mA
1.0
0.8
0.4
-400
0.2
0
-20
100 200 300 400 500
0
20
On-state voltage VON (mV)
Turn ON, Turn OFF time vs. LED forward current
100
tON
10
60
80
3.5
30
50
100
1.8
2.5
2.0
1.5
1.0
0.5
0.0
-20
100
IO = 100 mA
3.0
0
20
Ambient temperature Ta (°C)
Turn ON, Turn OFF time tON, tOFF (µs)
tOFF
1.6
4.0
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Load voltage
tON, tOFF - Ta
1000
1
40
Turn ON, Turn OFF time vs. Ambient temperature
tON, tOFF - IF
Ta = 25 °C
VDD = 20 V, RL = 200 Ω
1.4
LED forward voltage VF (V)
IFT - Ta
1.2
-300
5
100
1.4
0.6
3
80
2.0
-200
1
60
Trigger LED forward current IFT (mA)
300
10
3
On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature
On-state resistance RON (Ω)
Ta = 25 °C
IF = 5 mA
0
5
RON - Ta
500
-500
-500 -400 -300 -200 -100
10
Ambient temperature Ta (°C)
IO - VON
400
30
0.1
0
-20
120
Ta = 25 °C
50
0.3
ILEAK - VOFF
1000
Current leakage ILEAK (pA)
0
100
0.5
Ambient temperature Ta (°C)
Continuous load current IO (mA)
IF - VF
500
100
0
-20
Turn ON, Turn OFF time tON, tOFF (µs)
LED forward current vs. LED forward voltage
LED forward current IF (mA)
Continuous load current IO (mA)
Continuous load current vs. Ambient temperature
IF - Ta
LED forward current IF (mA)
LED forward current vs. Ambient temperature
VDD = 20 V
RL = 200 Ω, IF = 5 mA
500
300
tON
200
100
Ta = 25 °C
80
60
40
tOFF
100
20
50
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
0
10
20
30
40
50
60
Load voltage (V)
Output terminal capacitance vs. Load voltage
Output terminal capacitance COFF/COFF (0 V)
COFF - VOFF
1.2
Ta = 25 °C
1.0
0.8
0.6
0.4
0.2
0
0
10
20
30
40
Load voltage (V)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SSOP4 type
■ Appearance
SSOP (Shrink Small Outline Package)
SSOP4
416
Model name
OMRON mark
612
LOT.No.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
416
(Unit: mm)
Surface-mounting Terminals
612
Weight: 0.03 g
4.2
Actual Mounting Pad
Dimensions
(Recommended Value, TOP VIEW)
1.9
1.4 dia.
3.65
0.15
(0.3)
1.27
2.04
1.8
0.95 3.73
0.2
3.8
0.8
1.27
(0.46)
Unless otherwise specified, the
dimensional tolerance is ± 0.1 mm.
Note: The actual product is marked differently from the image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K210-E1-01
0412(0412)(O)
很抱歉,暂时无法提供与“G3VM-61LR-TR05”相匹配的价格&库存,您可以联系我们找货
免费人工找货