G3VM-62C1/F1
MOS FET Relays
Analog-switching MOS FET Relays for
High Switching Currents, with Dielectric
Strength of 2.5 kVAC between I/O.
• New 2-channel model included in the 60-V load voltage series.
• Switches minute analog signals.
• Dielectric strength of 2,500 Vrms between I/O.
• Surface-mounting models included in series.
Note: The actual product is marked differently from the
image shown here.
RoHS compliant
■ Application Examples
■ Terminal Arrangement/Internal Connections
• Test & Measurement equipment
8
7
6
5
• Security equipment
OMRON logo
1
3
2
Model
name
LOT.NO.
932
Pin 1 mark
4
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
Load voltage
(peak value) *
Terminals
PCB Terminals
2a
(DPST-NO)
DIP8
Minimum package quantity
Model
Number per tube Number per tape and reel
G3VM-62C1
60 V
Surface-mounting Terminals
G3VM-62F1
G3VM-62F1(TR)
50
-
-
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
VI-O
Ta
Tstg
-
Rating
50
1
−0.5
5
125
60
500
−5.0
125
2500
−40 to +85
−55 to +125
260
Unit
mA
A
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Ta ≥ 25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum
Unit
Measurement conditions
VF
IR
1.0
-
1.15
-
1.3
10
V
µA
IF = 10 mA
VR = 5 V
Capacity between terminals
Trigger LED forward current
CT
IFT
-
30
1.6
3
pF
mA
V = 0, f = 1 MHz
IO = 500 mA
Maximum resistance with output ON
Current leakage when the relay is open
RON
ILEAK
-
1.0
-
2.0
1.0
Ω
µA
IF = 5 mA, IO = 500 mA
VOFF = 60 V
Capacity between terminals
Capacity between I/O terminals
COFF
CI-O
-
130
0.8
-
pF
pF
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
Insulation resistance between I/O terminals
RI-O
1000
-
-
MΩ
VI-O = 500 VDC, ROH ≤ 60%
Turn-ON time
Turn-OFF time
tON
tOFF
-
0.8
0.1
2.0
0.5
ms
ms
IF = 5 mA, RL = 200 Ω,
VDD = 20 V(See note 2.)
Output
Input
LED forward voltage
Reverse current
1
Note: 2. Turn-ON and Turn-OFF Times
IF 1(3)
8(6)
2(4)
7(5)
RL
IF
VOUT
10%
t ON
90%
t OFF
VDD
VOUT
G3VM-62C1/F1
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
IO
Ta
5
−20
7.5
-
48
25
500
65
V
mA
mA
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
IO - Ta
80
60
40
20
0
-20
0
20
40
60
80
100
500
400
300
0.3
0
20
40
0
-200
100
0.4
IF = 5mA
4
3
2
-20
0
20
40
tON, tOFF - IF
60
VDD = 20V
RL = 200Ω
1000
500
300
tOFF
100
10
30
50
1.8
t < 1s
4
3
2
1
0
-20
100
0
20
tON
1000
300
tOFF
100
30
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Ambient
temperature
ILEAK - Ta
3000
30
VOFF = 60V
10
3
1
0.3
VDD = 20V
RL = 200Ω
tON
5
80
Current leakage ILEAK (nA)
Turn ON, Turn OFF time tON, tOFF (µs)
Ta = 25°C
1.6
IO = 500mA
tON, tOFF - Ta
3000
1.4
5
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs. Ambient
temperature
5000
1.2
IFT - Ta
IO = 500mA
0.6
Turn ON, Turn OFF time vs. LED
forward current
3
1
LED forward voltage VF (V)
0
0.2
50
0.8
Trigger LED forward current vs.
Ambient temperature
1
1
0.1
0.6
120
5
On-state voltage VON (V)
Turn ON, Turn OFF time tON, tOFF (µs)
80
On-state resistance vs. Ambient
temperature
-400
30
60
Trigger LED forward current IFT (mA)
200
0
3
Ambient temperature Ta (°C)
On-state resistance RON (Ω)
Continuous load current IO (mA)
400
-0.2
10
RON - Ta
Ta = 25°C
IF = 5mA
-0.4
30
100
IO - VON
600
-600
-0.6
Ta = 25°C
1
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
100
200
0
-20
120
IF - VF
600
LED forward current IF (mA)
100
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
IF = 5mA
100
300
10
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
0.1
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP8 type
■ Appearance
DIP (Dual Inline Package)
DIP8
OMRON logo
Model name
932
Pin 1 mark
LOT.NO.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit:mm)
PCB Terminals
Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW)
Weight: 0.54 g
Weight: 0.54 g
Eight, 0.8-dia. holes
2.54
(0.61)
2.54
9.66±0.25
9.66±0.25
6.4±0.25
7.62±0.25
Actual Mounting Pad Dimensions
0.8±0.25
7.62±0.25
(Recommended Value, TOP VIEW)
3.65 +0.15
−0.25
+0.1
0.25 −0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
7.85 to 8.80
3.65+0.15
−0.25
4.0+0.25
−0.2
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
image shown here.
2.54
1.0 min.
1.0 min.
10.0 max.
8.3 to 8.8
1.3
1.5
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K145-E1-01
0412(0412)(O)