0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G5CE-1-TP-DC5

G5CE-1-TP-DC5

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    Electromechanical Relay 5VDC 125Ohm 15A SPST-NO (25.1x22.1x11)mm THT Power Relay

  • 数据手册
  • 价格&库存
G5CE-1-TP-DC5 数据手册
PCB Relay G5C(E) Flat Relays that Switch 10-A/15-A Loads with New Quick-connect Terminals ■ ■ ■ ■ ■ Ideal for switching power in household appliances or for outputs from industrial devices. Subminiature dimensions: 22 ™ 16 ™ 11 mm (L ™ W ™ H). High-sensitivity models available with low power consumption (150 mW). UL and CSA approved. Fully sealed models and quick-connect terminal models available (#187 load contact terminals). RCE Ordering Information Contact form SPST-NO Enclosure ratings General purpose High-sensitivity High-capacity Flux protection G5C-1 G5C-1-H G5CE-1 G5CE-1-TP Fully sealed G5C-14 G5C-14-H --- --- Note: 1. When ordering, add the rated coil voltage to the model number. Example: G5C-1 12 VDC 2. 3. 4. 5. Rated coil voltage High-capacity models with a Fully sealed structure are not available. Standard or high-sensitivity models with quick-connect terminals are not available. VDE-approved models are available. Contact your OMRON representative for more details. Models with PTI250 are also available. Contact your OMRON representative for more details. Model Number Legend G5C 1 2 3 VDC 4 1. Relay None: Standard E: High-capacity 128 Quick-connect terminals 5 2. Number of Poles 4. Classification 1: 1 pole (SPST-NO) H: High-sensitivity 3. Enclosure Ratings TP: Quick-connect terminals (#187) None: Flux protection 5. Rated Coil Voltage 4: Fully sealed 3, 5, 6, 12, 24, 48 VDC G5C(E) G5C(E) Specifications ■ Coil Ratings Item Standard, high-capacity, or quick-connect terminals High-sensitivity Rated current 40 mA 16.7 mA 8.3 mA 30 mA 12.5 mA 24 VDC 6.25 mA Coil resistance 125 W 720 W 2,880 W 167 W 960 W 3,840 W Must operate voltage 75% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 150% (standard)/130% (high-capacity, quick-connect terminals) of rated voltage (at 23•C) 150% (at 23•C) Power consumption Approx. 200 mW Approx. 150 mW 5 VDC ■ 12 VDC 24 VDC 5 VDC 12 VDC 80% max. of rated voltage Contact Ratings Item Standard High-sensitivity High-capacity, or quick-connect terminals Resistive load (cosf = 1) Inductive load (cosf = 0.4, L/R = 7 ms) Resistive load (cosf = 1) Inductive load (cosf = 0.4, L/R = 7 ms) Resistive load (cosf = 1) Inductive load (cosf = 0.4, L/R = 7 ms) Rated load 10 A at 250 VAC; 10 A at 30 VDC 3 A at 250 VAC; 3 A at 30 VDC 10 A at 250 VAC; 10 A at 30 VDC 3 A at 250 VAC; 3 A at 30 VDC 15 A at 110 VAC; 10 A at 30 VDC 5 A at 110 VAC; 3 A at 30 VDC Rated carry current 10 A 10 A 15 A Max. switching voltage 250 VAC 250 VAC 250 VAC Max. switching current 10 A 10 A 15 A Max. switching power 2,500 VA, 300 W ■ 750 VA, 90 W 2,500 VA, 300 W 750 VA, 90 W 2,500 VA, 300 W 750 VA, 90 W Characteristics Contact resistance 30 mW max. (Quick-connect terminals type: 100 mW max.) Operate time 10 ms max. (High-sensitivity type: 15 ms max.) Release time 10 ms max. Insulation resistance 1,000 MW min. Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between contacts of same polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 4,500 V (1.2 x 50 µs) between coil and contacts Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 1,000 m/s2 Malfunction: 200 m/s2 Endurance Mechanical: 20,000,000 operations min. at 18,000 operations/hr Electrical: 300,000 operations min. (100,000 operations min. for Fully sealed Type) at 1,200 operations/hr under rated load of 10 A at 250 VAC; 100,000 operations min. under load of 15 A at 110 VAC for high-capacity models 100,000 operations min. at 1,200 operations/hr under rated load of 10 A at 30 VDC Ambient temperature Operating: -25°C to 70°C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 8 g (for TP model: Approx. 9.6 g) Note: ■ 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. Approved Standards UL508 (file No. E41515)/CSA C22.2 No.14 (file No. LR31928) Coil rating 3 to 100 VDC Contact rating 15 A, 125 VAC 10 A, 250 VAC 10 A, 30 VDC (resistive load only) 129 G5C(E) G5C(E) Engineering Data AC resistive load DC resistive load Ambient Temperature vs. Maximum Coil Voltage 250-VAC resistive load 100-VAC resistive load 30-VDC resistive load Switching voltage (V) Maximum coil voltage (%) Endurance Endurance (x103 operations) Switching current (A) Maximum Switching Power Continuous max. permissible voltage (10 A) Continuous max. permissible voltage (15 A) Switching current (A) Ambient temperature (°C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Orientation marks are indicated as follows: G5C(E)-1 22 max. (21.9)* 16 max. (15.9)* Terminal Arrangement/Internal Connections (Bottom View) Mounting Holes (PCB) 2.54 Two, 1 dia. 11 max. (10.9)* 1 3.5 1.6 0.6 10.16 0.3 0.4 4 12.7 7.62 2.54 2 3 *Average value 25.1 max. 4.8 1.3 dia. Terminal Arrangement/Internal Connections 22.1 max. 0.5 10°±1 3.2 6.35 13.3 4.9 11 3.6 0.3 16.1 0.3 1.35 5 Mounting Holes (Bottom View) Four, 1.2 dia. 1.8 elliptic holes Two, 1 dia. 4 3 0.5 14.25 17.78 (Top View) 0.6 14.25 6.25 17.78 2 1 (Bottom View) 130 2 Tow, 1 dia. elliptic holes G5CE-1-TP 1.6 16.1 21.1 5 G5C(E) G5C(E) Precautions Quick-connect Terminals The quick-connect terminals can be connected to an appropriate load. Consult your OMRON representative, however, when you intend to impose voltage on the quick-connect terminals mounted on a PCB. The terminals are compatible to the Fasten receptacle #187 positive block connector. The portion marked with oblique lines includes the charged terminals of the power relay. When you mount the power relay on a PCB, make sure any unnecessary metal patterns on the PCB are kept away from this portion. 12.7 8 6.5 0.18 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J085-E1-2A 131
G5CE-1-TP-DC5 价格&库存

很抱歉,暂时无法提供与“G5CE-1-TP-DC5”相匹配的价格&库存,您可以联系我们找货

免费人工找货