0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G79-I200C-175

G79-I200C-175

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    CABLE W/2 CONN INPUT 2M

  • 数据手册
  • 价格&库存
G79-I200C-175 数据手册
9 Relay Output Blocks G70D Compact, 16-Point Output Blocks Save Space in Control Panels 1 Compact standard version or quick-to-service vertical models 1 1 1 1 Power MOSFET or relays installed Built-in diode absorbs coil surge All have operation indicators Terminal blocks accept M3.5 fork-type crimp terminals 1 Expansion terminal block for vertical èò models allows power line connections 1 Mounts to DIN rail track or with screws 1 Dedicated cables for high-density PLC modules available (sold separately) Ordering Information 3 RELAY OUTPUT BLOCKS Appearance Output points 16 points (SPST NO x 16) (SPST-NO includes relay g tool. pulling Rated voltage 24 VDC Output type Internal I/O circuit common Part number NPN (+ common) G70D-SOC16 DC24 PNP (-- common) G70D-SOC16-1 DC24 NPN (+ common) G70D-FOM16 PNP (-- common) G70D-FOM16-1 DC24 Relay outputs NPN (+ common) G70D-VSOC16 Power MOSFET relay outputs NPN (+ common) G70D-VFOM16 Relay outputs Power MOSFET relay out uts outputs 16 points (SPST-NO x 16) 24 VDC G70D G70D 3 GENERAL-PURPOSE CONNECTING CABLES The following cables can be connected to I/O boards and PLC modules from any manufacturer. Length Item Connecting cable with crimp hook terminals Connecting cable with loose wires Part number 1 m (3.28 ft) G79-Y100C 1.5 m (4.92 ft) G79-Y150C 2 m (6.56 ft) G79-Y200C 3 m (9.84 ft) G79-Y300C 5 m (16.40 ft) G79-Y500C 2 m (6.56 ft) G79-A200C 5 m (16.40 ft) G79-A500C 3 DEDICATED CONNECTING CABLES FOR OMRON PLC MODULES The following cables are designed to connect directly to Omron PLC modules and have dedicated connectors for specific models. Item Connecting cable with one connector for high-density I/O modules Connecting cable with two connectors g y for high-density I/O modules d l Connecting cable with three connectors for CS1 highdensity I/O modules Length Part number 1 m (3.28 ft) G79-100C 1.5 m (4.92 ft) G79-150C 2 m (6.56 ft) G79-200C 3 m (9.84 ft) G79-300C 5 m (16.40 ft) G79-500C 1 m (3.28 ft) + 0.75 m (2.46 ft) G79-O100C-75 2 m (6.56 ft) + 1.75 m (5.74 ft) G79-O200C-175 3 m (9.84 ft) + 2.75 m (9.02 ft) G79-O300C-275 5 m (16.40 ft) + 4.75 m (15.58 ft) G79-O500C-475 1.5 m (4.92 ft) + 1.25 m (4.10 ft) + 1 m (3.28 ft) G79-150C-125-100 2 m (6.56 ft) + 1.75 m (5.74 ft) + 1.5 m (4.92 ft) G79-200C-175-150 3 m (9.84 ft) + 2.75 m (9.02 ft) + 2.5 m (8.20 ft) G79-300C-275-250 3 ACCESSORIES Item Applicable output blocks Rated voltage Part number Shorting bar G70D-VSOC16, G70D-VFOM16  G6D-4-SB Expansion terminal block G70D-VSOC16, G70D-VFOM16  G70D-ET Replacement relays y G70D-VSOC16, G70D-SOC16 24 VDC; minimum load 10 mA at 5 VDC G6D-1A DC24 G70D-VFOM16, G70D-FOM16 24 VDC G3DZ-2R6PL DC24 2 G70D G70D Specifications Power MOSFET Relay (G3DZ) Specifications 3 RATINGS The following values apply to the G6D Relay mounted to the G70D and do not apply to the G6D Relay itself before it is mounted. Electromechanical Relay (G6D) Specifications Coil Ratings The following values apply to the G3DZ Relay mounted to the G70D and do not apply to the G3DZ Relay itself before it is mounted. Input Ratings Rated voltage 24 VDC Operating voltage 19.2 to 28.8 VDC Rated voltage 24 VDC Rated current 10.5 mA Coil resistance 2,880 Ω Input impedance Must operate voltage 70% max. of rated voltage 4 kΩ ±20% Rated current Release voltage 10% min. of rated voltage 8.2 mA ±20% Max. allowable voltage 130% of rated voltage Power consumption Approx. 200 mW Note: 1. The must operate voltage is 75% max. of the rated voltage if the Relay is mounted upside down. 2. Rated current and coil resistance were measured at a coil temperature of 23EC (73.4EF) with a tolerance of ±10%. 3. Operating characteristics were measured at a coil temperature of 23EC (73.4EF). 4. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is no continuous allowance. 5. The rated current includes the current consumption of the operation indicator. Voltage level Must operate 19.2 VDC max. Must release 1 VDC min. Note: The rated current includes the current consumption of the operation indicator. Output Ratings Load voltage 3 to 264 VAC, 3 to 125 VDC Load current 100 µA to 0.3 A Inrush current 6 A (10 ms) Contact Ratings Load Resistive load (cosφ = 1) Rated load 3 A at 250 VAC, 3 A at 30 VDC Rated carry current 5 A (See Note 1) Max. switching voltage 250 VAC, 30 VDC Max. switching current 5A Max. switching capacity 1,250 VA, 150 W Error rate (level p) (reference value) (see note 2) 5 VDC, 1 mA Life expectancy Electrical: 100,000 operations min. (under and at the rated load at 1,800 operations/hr) Mechanical: 20,000,000 operations min. (at 18,000 operations/hr) Note: 1. This value is for when the maximum 8 points are ON. 2. This value is for a switching frequency of 120 times per minute. 3 G70D G70D 3 CHARACTERISTICS Part number G70D-VSOC16/ G70D-SOC16 (-1) Output type Relay outputs Contact form 16 points (SPST-NO x 16) Contact mechanism Single  Contact resistance 100 mΩ max. measured at 1 A, 5 VDC  Insulation method  Photocoupler Must operate time 10 ms max. at 23°C (73.4°F) ambient temperature 6 ms max. Release time 10 ms max. at 23°C (73.4°F) ambient temperature 10 ms max. Output ON-resistance  2.4 Ω max. Leakage current at OFF-state  10 µA max. at 125 VDC Max. switching frequency Mechanical: 18,000 operations/hr Rated load: 1,800 operations/hr  Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC for 1 min between coil and contact Noise immunity Power input (normal mode): Power input (common mode): Input cable (coiling): Unit body (coiling): Vibration resistance Shock resistance G70D-SOC16(-1) G70D-VFOM16/ G70D-FOM16 (-1) G70D-FOM16 (-1) Power MOSFET Relay outputs 2,000 VAC for 1 min between input and output terminals 600 V for 10 min with a pulse width of 100 ns/1 µs 1.5 kV for 10 min with a pulse width of 100 ns/1 µs 1.5 kV for 10 min with a pulse width of 100 ns/1 µs 600 V for 10 min with a pulse width of 100 ns/1 µs Destruction 10 to 55 Hz, 1.0--mm double amplitude for 2 hrs each in X, Y, and Z directions Malfunction 10 to 55 Hz, 0.75--mm double amplitude for 2 hrs each in X, Y, and Z directions Destruction 300 m/s2 Malfunction 100 m/s2 Operating voltage range 24 VDC +10%/ --15% Current consumption Approx. 170 mA at 24 VDC (See Note 2) Cable length Between block and controller: 5 m max. (reference value for AWG28) Between block and external device: Dependent on load LED color Operation indicator: orange Operation indicator: orange Power supply: green Operation indicator: orange Operation indicator: orange Power supply: green Coil surge absorber Ambient temperature Ambient humidity Approx 300 mA at 24 VDC (See Note 2) Approx. 125 mA at 24 VDC (See Note 3) Approx. 300 mA at 24 VDC (See Note 3) Diode (600 V, 1 A) Diode (400 V, 0.3 A) Diode (600 V, 1 A) Diode (400 V, 0.3 A) Operating --25°C to 55°C (--13°F to 131°F) with no icing or condensation 0°C to 55°C (32°F to 131°F) with no icing or condensation --25°C to 55°C (--13°F to 131°F) with no icing or condensation 0°C to 55°C (32°F to 131°F) with no icing or condensation Storage --25°C to 65°C (--13°F to 149°F) with no icing or condensation --20°C to 65°C (--4°F to 149°F) with no icing or condensation --25°C to 65°C (--13°F to 149°F) with no icing or condensation --20°C to 65°C (--4°F to 149°F) with no icing or condensation Operating 45% to 85% RH 35% to 85% RH 45% to 85% RH 35% to 85% RH Mounting strength No damage when 49 N pull load was applied for 1 s in all directions (except for 9.8 N min. in direction of rail) Terminal strength Tightening torque: 0.78 to 1.18 N : m Pull strength: 49 N for 1 min Weight (See Note 4) Approx. 280 g Approx. 200 g Approx. 280 g Approx. 200 g Note: 1. The above values are initial values. 2. Current consumption is when all points are ON and includes G6D Relay coil current but does not include any external load current. 3. Current consumption is when all points are ON and includes G3DZ input current but does not include any external load current. 4. The Relay Output Block weighs approximately 315 g with the Expansion Terminal Block mounted. 4 G70D G70D Engineering Data 3 RELAY OUTPUT MODELS G70D-SOC16(-1)/G70D-VSOC16 DC resistive load Life Expectancy AC resistive load Life expectancy (x 104 operations) Switching current (A) Max. Switching Capacity Switching voltage (V) 250 VAC/30 VDC resistive load Switching current (A) 3 POWER MOSFET OUTPUT MODELS G70D-FOM16(-1)/G70D-VFOM16 Inrush Current Resistivity Non-repetitive (Keep the inrush current to half the rated value or less if it occurs repeatedly.) Load current (A) Inruch current (A.Peak) Load Current vs. Ambient Temperature Characteristics Ambient temperature (°C) Energizing time (ms) 5 G70D G70D Operation 3 INTERNAL CIRCUIT G70D-SOC16/G70D-FOM16 NPN-compatible output terminal (+ common output): A controller with an NPN transistor (-- common output) can be connected. Connector Terminal Arrangement (Top View) A0...(1)20 19(11)...A8 A1...(2)18 17(12)...A9 A2...(3)16 15(13)...A10 A3...(4)14 13(14)...A11 A4...(5)12 11(15)...A12 A5...(6)10 9(16)...A13 A6...(7) 8 7(17)...A14 A7...(8) 6 5(18)...A15 0 V..(9) 4 3(19)...0 V 24 V...(10)2 1(20)...24 V Connector pin No. I/O indications on Screw Terminals (Black triangle mark) Note: Connector pin numbers in parentheses are for G79 Cable. The pin numbers are indicated for user’s convenience. The black triangle mark can be used to determine orientation. Note: Wiring shown above is for G6D Power Relays. G70D-SOC16-1/G70D-FOM16-1 PNP-compatible output terminal (-- common output): A controller with an PNP transistor (+ common output) can be connected. Connector Terminal Arrangement (Top View) A0...(1)20 19(11)...A8 A1...(2)18 17(12)...A9 A2...(3)16 15(13)...A10 A3...(4)14 13(14)...A11 A4...(5)12 11(15)...A12 A5...(6)10 9(16)...A13 A6...(7) 8 7(17)...A14 A7...(8) 6 5(18)...A15 0 V..(9) 4 3(19)...0 V 24 V...(10)2 1(20)...24 V Connector pin No. I/O indications on Screw Terminals (Black triangle mark) Connector pin numbers in parentheses are for G79 Cable. Note: The pin numbers are indicated for user’s convenience. The black triangle mark can be used to determine orientation. Note: Wiring shown above is for G6D Power Relays. 6 G70D G70D G70D-VSOC16/G70D-VFOM16 NPN-compatible output terminal (+ common output): A controller with an NPN transistor (-- common output) can be connected. Connector Terminal Arrangement (Top View) Connector pin No. I/O indications on Screw Terminals (Triangle mark) With Expansion Terminal Block Note: 1. The terminal block shows the G70D-VSOC16, which operates with G6D relays mounted. The G70D-VFOM16 terminal block uses G3DZ power MOSFET relays in place of G6D relays. 2. Terminals C0 to C15 are electrically independent from each other. 3. When the terminal block and relay block are connected to each other, each electrical check terminal of the relay block is connected to the corresponding terminal of the terminal block. 3 TERMINAL ARRANGEMENT AND LOAD CONNECTION EXAMPLES Load Load Load Power supply Load Power supply Power supply Load Power supply Load Load Load Load Load Load Power supply Load Power supply Load Power supply Load Load Load Power supply 24 VDC Power supply Connector G70D-SOC16(-1)/G70D-FOM16(-1) Note: 1. Dotted lines show internal connections. 2. B2, B3, B4, and B5 are each found in two locations. Connect power to either of them. 7 G70D G70D Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load 24 VDC Load G70D-VSOC16/VFOM16 Without Expansion Terminal Block G70D-VSOC16/VFOM16 With Expansion Terminal Block Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load Load 24 VDC Electrical check terminals (See Note) Connector Operation indicators Note: When the terminal block and relay block are connected to each other, each electrical check terminal of the relay block is connected to the corresponding terminal of the terminal block. 8 G70D G70D Dimensions Unit: mm (inch) G70D-SOC16(-1) G70D-FOM16(-1) 53 (2.09) 25 (0.98) 156 (6.14) max. 135±0.2 (5.31±0.008) 54 (2.12) 40±0.2 (1.57 ±0.008) 51 (2.01) max. 7 6 30--M 3 6 39 (1.53) max. Mounting Holes Two, 4.2 dia. or M4 40±0.2 (1.57 ±0.008) 135±0.2 (5.31±0.008) G70D-VSOC16 G70D-VFOM16 81 (3.19) max. 46.5 (1.83) 135 (5.31) 5 100±0.2 (3.94±0.008) 46 (1.81) max. 54.5 (2.15) max. 50±0.2 (1.97 ±0.008) Relay block Terminal block Terminal Block (with Expansion Terminal Block) Terminal Block (without Expansion Terminal Block) 135 (5.31) max. 6.8 10 10 40 (1.57) max. 11.6 13.6 2 3 7.62 12.8 34, M3 Phillips-head screws Mounting Holes 7.62 6.2 min. 6.2 min. 50, M3 Phillips-head screws Two, 4.2 dia. or M4 holes 50±0.2 (1.97 ±0.008) 100±0.2 (3.94±0.008) 9 G70D G70D 3 GENERAL-PURPOSE CONNECTING CABLES Unit: mm (inch) G79-YPC Cable with Crimp Terminals Convenient for connecting screw terminals to Output Blocks Side A Side B Connecting to devices Connecting to G70D Relay Output Block ç 300 G79-APC Cable with Loose Wires Device connection end provides loose wires. Side A Side B Connecting to peripheral devices Connecting to G70D Relay Output Block ç 300 With loose wires and crimp terminals 1,000 mm (3.28 ft) 1,500 mm (4.92 ft) 2,000 mm (6.56 ft) 3,000 mm (9.84 ft) 5,000 mm (16.40 ft) With loose wires Part number Length (ç) Part number Length (ç) G79-Y100C G79-Y150C G79-Y200C G79-Y300C G79-Y500C 2,000 mm (6.56 ft) 5,000 mm (16.40 ft) G79-A200C G79-A500C 3 DEDICATED CONNECTING CABLES FOR OMRON PLC MODULES Guidelines The number of I/O points used must correspond to the number of Output Blocks. The number of I/O connectors used must correspond to the number of cables. G79-PC Cable with Connector (1:1) Side A Side B Connection to PLC high--density output modules Connection to G70D Relay Output Block ç Applicable Omron PLC High-density I/O Modules Part number C200H-OD215 C200H MD215 C200H-MD215 C500-OD415CN C500-MD211CN C500 MD211CN 10 Connector Cable for Output Blocks No. of output points 32 output points (2 ( cables)) 16 inputs/16 i t /16 outputs t t (1 cable) bl ) 32 output points (2 cables) 16 inputs/16 in uts/16 outputs out uts (1 cable) Length (ç) Part number 1,000 mm G79-100C 1,500 mm G79-150C 2,000 mm G79-200C 3,000 mm G79-300C 5,000 mm G79-500C G70D G70D G79-OPC-P Cable with Connector (1:2) A Side A Side B Connection to PLC high-density output modules Connection to G70D Relay Output Blocks CN2 CN1 B Straight length Connector Cable for Output Blocks Applicable pp Omron PLC High-density Hi hd it I/O Modules M d l Part number C200H-OD218 C200H OD219 C200H-OD219 C500-OD213 CQM1-OD213 CQM1 OD213 Part number Length (ç) No. of output points 32 points (1 ( cable)) 64 points i t (2 cables) bl ) 64 points (2 cables) 32 points oints (1 cable) A B 1,000 mm (3.28 ft) 750 mm (2.46 ft) G79-O100C-75 1,500 mm (4.92 ft) 1,250 mm (4.10 ft) G79-O150C-125 2,000 mm (6.56 ft) 1,750 mm (5.74 ft) G79-O200C-175 3,000 mm (9.84 ft) 2,750 mm (9.02 ft) G79-O300C-275 5,000 mm (16.40 ft) 4,750 mm (15.58 ft) G79-O500C-475 G79-PC-P-P Cable with Connector (1:3) A Side A B Side B Connection to PLC high-density output modules CN3 Connection to G70D Relay Output Blocks CN2 CN1 C Straight length Connector Cable for Output Blocks Applicable pp Omron PLC High-density Hi hd it I/O Modules M d l Part number CS CS1W-OD29P O 9 CS1W MD29 CS1W-MD29P No. of output points 96 points (2 ( cables)) 48 inputs/48 i t /48 outputs t t (1 cable) Part number Length (ç) A B C 1,500 mm (4.92 ft) 1,250 mm (4.10 ft) 1,000 mm (3.28 ft) G79-150C-125-100 2,000 mm (6.56 ft) 1,750 mm (5.74 ft) 1,500 mm (4.92 ft) G79-200C-175-150 3,000 mm (9.84 ft) 2,750 mm (9.02 ft) 2,500 mm (8.20 ft) G79-300C-275-250 11 G70D G70D 3 ACCESSORIES Unit: mm (inch) These accessories are for G70D-VSOC16 and G70D-VFOM16 Terminal Blocks. G70D-ET Expansion Terminal Block 24.75 (0.97) 131.8 (5.19) 11 10.65 (0.42) 6.3 7.62 G6D-4-SB Short Bar 9.6 (0.38) 28.56 (1.12) Precautions 3 GENERAL PRECAUTIONS The G70D is used only for outputs. If the Output Block is connected to a DC inductive load, connect a diode to the Output Block to protect against counterelectromotive voltage. This may result in damage to the output element and a short or open--circuit malfunction. Electric Shock It is extremely dangerous to connect or disconnect relays with the power turned on. Always turn off the power before wiring the Output Block or replacing the relays. 3 CORRECT USE Do not connect or disconnect connectors with the power turned on; faulty operation may occur. The G70D-SOC16(-1) and G70D-VSOC16 are equipped with G6D-1A, 24 VDC relays. The G70D-FOM16(-1) and G70D-VFOM16 are equipped with G3DZ-2R6PL, 24 VDC power MOSFET solid state relays. Wiring Be sure to turn OFF the power when wiring the Output Block and do not touch the charged terminals of the Output Block, or an electric shock may result. Turn ON the power after the Output Block is wired and the relay block is mounted. Apply specified voltages to the input terminals. Otherwise, the Output Block may malfunction, be damaged, or burn. Relay Models Do not connect the Output Block to any load exceeding the rated switching voltage or current of the Output Block. Otherwise, faulty insulation, contact weld, or faulty contact of the Relays, damage to the Relays may result or the Relays may malfunction or burn. The life of a Relay varies with the switching condition. Test the Relays under the actual operating conditions before using the Relays within the permissible switching frequency. The use of deteriorated Relays may result in the faulty insulation of the Relays or cause the Relays to burn. Do not use the Output Block in places with flammable gas. A fire or explosion may result from the heat of the Relays or a spark from the Relays when they are switched. Power MOSFET Models Do not connect the Output Block to loads consuming a total current exceeding the rated output current of the Output Block. You may damage the output element and a short or open--circuit malfunction may result. 12 Replacing Relays Turn OFF the Output Block to replace Relays. Otherwise, an electric shock may result or the Output Block may malfunction. Mount the Relay by pressing the upper part straight down until the Relay is locked with the hooks. Make sure none of the Relay terminals are bent or the Output Block may malfunction or radiate heat. Wiring Make sure that the polarity of each terminal is correct, the power lines are wired properly, and the terminal voltage is appropriate. Do not disconnect or connect the connector while the Output Block is turned ON. Otherwise, the Output Block may malfunction. Cable Connector Locks Before the Output Block is turned ON, make sure that the connectors of all the cables connected to the Output Block are locked. G70D G70D Installation Environment Do not install the Output Block in the following locations or damage or malfunction may result. - Locations with direct sunlight. - Locations with ambient temperature ranges not within --25°C to 55°C (--13°F to 131°F). Terminal block - Locations with rapid temperature changes resulting in condensation or relative humidity exceeding 45% to 85%. Expansion terminal block - Locations with corrosive or inflammable gas. - Locations with excessive dust, salinity, or metal powder. - Locations with vibration or shock affecting the Output Block. - Locations with water, oil, or chemical sprayed on the Output Block. Relay block Screw Tightening Torque Removing and Mounting the Terminal Block and Relay Block Tighten all screws of the Output Block properly, or the Output Block may malfunction. Refer to the diagram below. 1. Removing - Terminal screws: Tighten each terminal screw to a torque of 0.78 to 1.18 N : m. Check that the load and the Output Block are both turned OFF. - Mounting screws: Tighten each mounting screw to a torque of 0.59 to 0.98 N : m Turn the mounting screws of the relay block counterclockwise alternately and equally until the relay block is slightly raised. - Relay block mounting screws: Tighten each mounting screw to a torque of 0.59 to 0.98 N : m. When the relay block is slightly raised, disconnect the protruding part A of the relay block from the interior wall of the Output Block. Cleaning Do not use paint thinner to clean the surface because damage or discoloration may result. Further turn the mounting screws counterclockwise and remove the mounting screws. Then remove the relay block. 2. Mounting Handling Check that the load and the Output Block are both turned OFF. Do not drop the Output Block or shock or vibrate the Output Block excessively. This may damage the Output Block and result in malfunction. Check that the part B of he terminal block is free of metal dust or other foreign materials. Disassembling, Repairing, and Modifying Mount the relay block straight along the groove of the terminal block. Do not disassemble, repair, or modify the Output Block. An electric shock may result or the Output Block may malfunction. Press the both ends of the relay block and place the protruding part A onto the interior wall of the Output Block. Output Block Configuration G70D-SOC/G70D-FOM To open the protective cover, lift cover at both points marked “A” in the following illustration. Tighten the mounting screws of the relay block clockwise alternately and equally to secure the relay block Mounting screws Relay block Use the Relay Removal Tool provided to the left of the screw terminals when replacing relays. G70D-VSOC/G70D-VFOM Terminal block For ease-of-use and space-saving, the G70D-VSOC16 incorporates a terminal block and relay block that can be separated from the Output Block. The relay block has operation indicators and replaceable Relays along with electrical check terminals for monitoring the operation of the Output Block. The Expansion Terminal Block can be mounted to the Output Block for power line connections. 13 G70D G70D Nameplate of Terminal Block Electrical Check Terminals As shown in Figure 1, the nameplate of the terminal block is located on the bottom surface of the relay block. The terminal block of the G70D-VSOC16 in operation is located under the relay block. Therefore, unlike the terminal blocks of other models, electrical checks on the terminals are not possible with multimeter probes. The relay block of the G70D-VSOC16, however, incorporates electrical check terminals, each of which is connected to the corresponding terminal of the terminal block. All the pairs of these terminals share single terminal numbers respectively. To fill in the nameplate, remove the nameplate from the relay block. Then return it to the original location when finished. To read the nameplate after the Output Block is mounted to a panel, for example, pull out the nameplate from the bottom surface of the relay block as shown in Figure 2. To check these terminals, apply multimeter probes to these terminals. Do not touch these energized terminals with a thin metal object or similar objects. Doing so may result in an electric shock. Relay block Nameplate Figure 1 Multimeter probes Nameplate Electrical check terminals Figure 2 Mounting the Expansion Terminal Block Insert the hooks of the Expansion Terminal Block into the mounting holes on the terminal block and slide the Expansion Terminal Block so that it will not separate from the terminal block. Tighten the mounting screw of the Expansion Terminal Block securely. Terminal block Mounting screw Expansion Terminal Block NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. 9 OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V 1-800-55-OMRON 416-286-6465 Cat. No. J099-E3-1 04/00 Specifications subject to change without notice. Printed in U.S.A.
G79-I200C-175 价格&库存

很抱歉,暂时无法提供与“G79-I200C-175”相匹配的价格&库存,您可以联系我们找货

免费人工找货