Test Procedure for the NV706271R2DBGEVB Evaluation Board
For the test of this DUT, the ON semiconductor evaluation kit for the AMIS_306xx and ON Semi_30627 has to be used. The
procedure assumes that the test engineer is familiar with the use of the evaluation board and the GUI software.
Wire up the Evaluation kit and install the DUT.
3/30/2013
1
www.onsemi.com
DUT
At initial start-up place the jumpers at the evaluation board as follows:
HW0 at GND position
HW1 at GND position
HW2 at GND position
SWI at GND position
Power up the evaluation board.
Start the GUI software of the kit.
3/30/2013
2
www.onsemi.com
Adjust USB operation in the options menu.
Guarantee that dummy LIN frames are regularly send (400ms).
After LIN set-up start the motor commander.
LIN configuration
Motor Commander
LIN Target ->
USB
This should be
tagged
3/30/2013
3
www.onsemi.com
Node address
70627
Get Full Status
SetMotorParam
Set Position
3/30/2013
4
www.onsemi.com
Tests:
1) Device accessibility via LIN at LIN address 00:
Perform a GetFullStatus command 2 times by clicking the GetFullStatus button twice.
The DUT should respond with an in frame status respond: 7D 80 00 00 xx xx 10 74 00
2) SWI input check:
Remove jumper SWI and perform again a GetFullStatus command:
Check if the status bit is presenting that the SWI input is changed.
The DUT should respond with an in frame status respond: 7D 80 00 00 xx xx 00 74 00
3) Device accessibility via LIN at LIN address 40:
Switch off the Evaluation board and place jumper HW0 to position VDD
Switch on the Evaluation board.
First perform a GetFullStatus command 2 times at LIN address 00 by clicking the GetFullStatus button twice.
The DUT should not respond. The GetFullSatus is presented as: 7D 00 00 00 00 00 00 00 00
Change the LIN address in the GUI to 40:
3/30/2013
5
www.onsemi.com
Again perform a GetFullStatus command.
Now, the DUT should respond with its status: 7D C0 00 00 00 00 00 74 00
4) Device accessibility via LIN at LIN address 20:
Switch off the Evaluation board and place jumper HW0 back to position GND and place jumper HW1 to VDD
Switch on the Evaluation board.
Repeat the command as mentioned in the previous test with the LIN address set to 20.
Check again the DUT status response: 7D C0 00 00 00 00 00 74 00
5) Device accessibility via LIN at LIN address 10:
Switch off the Evaluation board and place jumper HW1 back to position GND and place jumper HW2 to VBAT
Switch on the Evaluation board.
Repeat the command as mentioned in the previous test with the LIN address set to 10.
Check again the DUT status response: 7D C0 00 00 00 00 00 74 00
3/30/2013
6
www.onsemi.com
6) Motor Operation in Forward and Backward directions:
Set the motor parameters as presented in following picture:
Give a position with the position slider and click the Set Position Command button. The motor should perform a positioning to
the given position.
Slide back the position slider and click the Set Position Command button again. The motor should now perform a motion in
opposite direction.
The test is positively finished when above responses and reactions are given. Switch off the Evaluation kit and remove the DUT.
When removing the DUT, prevent for bending the connector pins!
3/30/2013
7
www.onsemi.com
DUT: ……………………………..
Test:
1
2
3
4
5
6
3/30/2013
Date: ……………………….. Operator: ……………………….
Description:
Passed:
Device accessibility via LIN at LIN address 00
SWI input check
Device accessibility via LIN at LIN address 40
Device accessibility via LIN at LIN address 40
Device accessibility via LIN at LIN address 40
Motor Operation in Forward and Backward directions
8
www.onsemi.com
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
onsemi:
NV706271R2DBGEVB
很抱歉,暂时无法提供与“NV706271R2DBGEVB”相匹配的价格&库存,您可以联系我们找货