Mini-Com TX5e and TX6 PLUS
UTP Jack Modules
Part Numbers: CJ5E88T**, CJD5E88T**, CJ688TP**, CJD688TP**, KJ688TP**
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2015
1
PN307K
T568B
2
T568A
1"
(25.4mm)
Wiring sequence
B
A
{Not to scale}
3
T568B
4
1
3
!
Follow order
carefully so
wires overlap
properly in the
next step.
T568B
8
T568A
10
10
8
1
3
T568B
6
T568A
2
4
2
4
5
T568A
!
7
5
6
5
!
Blue/white
wire should
overlap and
be parallel to
green wire
as shown.
7
Blue/white
wire should
overlap and
be parallel to
orange wire
as shown.
9
6
8
7
Ensure conductors are
secure in slots before
cutting flush with cap.
9
Note: Bending the cable may cause
conductors to become unsecured
and termination to fail.
Keep cable straight. Verify
conductors are visible and
secured in place.
“TOP”
T568B
DO NOT BEND
CABLE!
CGJT
T568A
CWST
For Technical Support: www.panduit.com/resources/install_maintain.asp
** Denotes color.
Page 1 of 2
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2015
PN307K
TERMINATION CAP REMOVAL
1
2
3
5
4
JACK MODULE INSTALLATION / REMOVAL
Mini-Com style jack modules
Keystone style jack modules
INSTALL
INSTALL
REMOVE
REMOVE
Depress latch
on module
1
2
3
2
3
2
2
1
1
Notes:
1. For specified performance, follow ANSI/NECA/BICSI-568-2006
installation guidelines.
2. Jack modules can terminate PVC or Plenum rated 22-24 AWG solid or
stranded IWC cable with insulated conductor outside diameter ranging
between 0.035 inch (0.88mm) and 0.048 inch (1.2mm).
3. Jack modules may be re-terminated a minimum of 10 times.
4. For technical and performance information, consult Panduit Technical
Support.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is
specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the
communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
Pin #’s
T568B
8
7
6
5
4
3
2
1
1
8
T568A
8
7
6
5
4
3
2
1
7 8
4 6
5 3
2 1
E-mail:
techsupport@panduit.com
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
Wiring Sequences
www.panduit.com
Page 2 of 2
Phone:
866-405-6654
7 8
4 6
5 3
2 1
Termination for Right Hand Lay Cable
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2015
2
1
PN580A
T568B
T568A
1"
(25.4mm)
Wiring sequence
B
A
{Not to scale}
3
4
T568B
4
1
3
5
!
Follow order
carefully so
wires overlap
properly in the
next step.
T568B
6
6
T568A
T568A
2
3
T568B
6
1
4
2
T568A
9
9
!
7
5
8
7
5
Orange/white
wire should
overlap and
be parallel to
blue wire
as shown.
10
10
8
8
7
!
Green/white
wire should
overlap and
be parallel to
blue wire
as shown.
Ensure conductors are
secure in slots before
cutting flush with cap.
Note: Bending the cable may cause
conductors to become unsecured
and termination to fail.
Keep cable straight. Verify
conductors are visible and
secured in place.
“TOP”
T568B
DO NOT BEND
CABLE!
CGJT
T568A
CWST
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 1