Mini-Com ® TX6 ™ PLUS Corrosive Resistant
UTP Jack Modules
SPECIFICATION SHEET
specifications
Category 6/Class E, 8-position, UTP jack module shall terminate 4-pair,
22 – 26 AWG, 100 ohm unshielded twisted pair cable and shall not
require use of a punchdown tool. Polymer based gel shall protect
electrical contacts and internal components by reducing the ingress of
moisture and other corrosive elements such as salt, providing improved
long term performance. UTP jack modules shall use a forward motion
termination method to optimize performance by maintaining cable pair
geometry while eliminating conductor untwist. The termination cap shall
be color-coded white to designate Category 6 performance and shall
include a universal label coded for T568A and T568B wiring schemes.
technical information
Category 6/Class E
channel performance:
FCC and ANSI
compliance:
IEC compliance:
PoE compliance:
UL rated:
Conductor termination
range:
RoHS compliancy status:
Exceeds channel requirements of ANSI/TIA-568-C.2 Category 6 and
ISO 11801 Class E standards at swept frequencies 1 to 250 MHz
Meets all applicable ANSI/TIA-968-A requirements; contacts plated
with 50 microinches of gold for superior performance
Meets IEC 60603-7
Meets requirements of IEEE 802.3af and IEEE 802.3at for PoE applications
UL 1863 approved
Wire cap compatible with 22 – 26 AWG solid or stranded cable with
conductor insulation diameters of 0.060 in. max and overall cable
O.D. 0.200 in. to 0.330 in.
Compliant
key features and benefits
Polymer based gel
High temperature
resistant material
100% performance tested
Utilizes enhanced
Giga-TX ™ Technology
Improved termination cap
Modular
True strain relief
Individually serialized
RJ45 interface
Identification
Termination tools (optional)
Block out device (optional)
Protects electrical contacts and internal components by reducing
the ingress of moisture and other corrosive elements such as salt,
providing improved long term performance; operation life 75+ insertions
Enables operations in environments up to 70°C; ideal for use in warm
temperature environments or network hot spots
Confidence that each jack module will deliver the critical electrical
performance requirements
Optimizes performance by eliminating conductor untwist and reduces
installation time and expense
Conductor retention slots simplify jack module termination
UTP jack modules snap in and out of all Mini-Com ® Faceplates,
Modular Patch Panels and Surface Mount Boxes for easy moves,
adds and changes
Controls cable bend radius for long-term installed performance
Marked with quality control number for future traceability
Industry standard interface provides a quick and easy plug and play
connection to RJ45 patch cords; backwards compatible
Can be clearly identified with optional labels and icons for port identification
EGJT termination tool ensures conductors are fully terminated by utilizing
a smooth forward motion without impact on critical internal components for
maximum reliability; TGJT termination tool ideal for high volume installations
Provides a simple and secure method to control access to data ports
while not in use
applications
Mini-Com® TX6™ PLUS Corrosive Resistant UTP
Jack Modules are a component of the TX6™ PLUS
UTP Copper Cabling System. This end-to-end
system provides Gigabit Ethernet performance
with usable bandwidth beyond 250 MHz. With
performance to the ANSI/TIA-568-C.2 Category 6
and ISO 11801 Class E Edition 2.1 standards,
this system will support the following applications:
w w w. p a n d u i t . c o m
• Ethernet 10BASE-T, 100BASE-T (Fast
Ethernet), 1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Digital video and broadband/baseband
analog video
• Voice over Internet Protocol (VoIP)
TX6 ™ PLUS UTP Copper
Cabling System
Mini-Com ® TX6 ™ PLUS Corrosive
Resistant UTP Jack Module
Jack module:
CJE688TGIW*
TX6500 ™ UTP Copper Cable
Plenum:
PUP6504**
Riser:
PUR6504**
TX6000 ™ UTP Copper Cable
Plenum:
PUP6004**
Riser:
PUR6004**
LSZH:
PUL6004**
CM:
PUC6004***
TX6 ™ PLUS UTP Patch Cords
CM (Foot lengths):
UTPSP^Y
CM (Meter lengths): UTPSP^^MY
LSZH (Meter lengths): UTPSPL^^MY
Mini-Com ® Angled Modular
Patch Panels
24-port, 1 RU:
CPPLA24WBLY
48-port, 2 RU:
CPPLA48WBLY
Mini-Com ® Flat Modular
Patch Panels
24-port, 1 RU:
CPPL24WBLY
48-port, 2 RU:
CPPL48WBLY
For additional modular and punchdown
patch panels, visit www.panduit.com.
GP6 ™ PLUS 110 Punchdown System
Visit www.panduit.com for complete
system information.
Tools and Accessories
Jack module
termination tools:
EGJT or TGJT
Wire snipping tool:
CWST
Wire stripping tool:
CJAST
Clear dust cap:
MDC-C
Block out device:
PSL-DCJB-^^^
Phone icons:
CIPIW-C‡
Data icons:
CIDIW-C‡
*To designate color other that IW (Off White), replace
IW suffix with WH (White), BL (Black), RD (Red), or
BU (Blue).
**To designate color, add suffix BU (Blue) or
WH (White). For additional cable colors, contact
customer service.
^For lengths 1 to 20 feet (one foot increments) and
25, 30, 35, 40 feet, change the length designation in
the part number to the desired length. For standard cable
colors other than Off White, add suffix BL (Black), BU
(Blue), RD (Red), YL (Yellow), GR (Green),
OR (Orange), or VL (Violet). For example, the part
number for a blue 15-foot patch cord is UTPSP15BUY.
^^For lengths 1 to 10 meters (one meter increments)
and 2.5, 15, 20, 25, 30, 35, 40 meters, change the length
designation in the part number to the desired length. For
standard cable colors other than Off White, add suffix BL
(Black), BU (Blue), RD (Red), YL (Yellow), GR (Green),
OR (Orange), or VL (Violet). For example, the part number
for a blue 15-meter patch cord is UTPSP15MBUY.
^^^To To designate color other than Red, add suffix
BL (Black), BU (Blue), YL (Yellow), GR (Green), OR
(Orange), IW (Off White), or IG (International Gray)
at the end of the part number. 10/package.
‡To designate color other than IW (Off White), replace
IW with EI (Electric Ivory), IG (International Gray),
BL (Black), BU (Blue), RD (Red), YL (Yellow),
GR (Green), OR (Orange), or VL (Violet) in the
part number. 100/package.
Contact customer service for bulk packaged
and/or keyed jack modules and patch cords.
Mini-Com ® TX6 ™ PLUS Corrosive Resistant UTP Jack Modules
test results
Mechanical Test
Normal Force
Vibration
Shock
Test Method
–
IEC 512-6d
Measurement
Load (grams)
Circuit Resistance (mOhms)
Typical Test Results
> 100
< 40
IEC 512-6c
Contact Disturbance (microsecond)
20
Test Method
IEC 512-2a
IEC 512-4a
Measurement
Resistance (mOhms)
1000 V, 1 minute
Typical Test Results
< 20
Passed
IEC 512-3a
Resistance (MOhms)
> 500
Test Method
Measurement
IEC 512-9b
Circuit Resistance (mOhms)
Typical Test Results
< 40
Humidity
IEC 512-11c
Circuit Resistance (mOhms)
< 40
Thermal Shock
IEC 512-11d
Circuit Resistance (mOhms)
< 40
Climatic Sequence
IEC 512-11a
Circuit Resistance (mOhms)
< 40
IEC 512-11g
Circuit Resistance (mOhms)
< 40
TR-NWT-001334
Test 5.11
Circuit Resistance (mOhms)
>10
Durability
Mating/Unmating
Termination Cycles
Electrical Test
Low Level Circuit Resistance
Dielectric Withstand Voltage
Insulation Resistance
Environmental
Temperature Life
Flowing Mixed Gas Corrosion
Salt Fog Test
Strain Relief Clip
Wire Cap
Module Housing
.71
[18.06]
.62
[15.87]
1.50
[38.15]
Dimensions are in inches. [Dimensions in brackets are metric].
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
cs-emea@panduit.com
Phone: 44.20.8601.7200
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
Phone: 65.6305.7575
PANDUIT JAPAN
Tokyo, Japan
cs-japan@panduit.com
Phone: 81.3.6863.6000
PANDUIT LATIN AMERICA
Guadalajara, Mexico
cs-la@panduit.com
Phone: 52.33.3777.6000
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
cs-aus@panduit.com
Phone: 61.3.9794.9020
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
For more information
Visit us at www.panduit.com
Contact Customer Service by email: cs@panduit.com
or by phone: 800-777-3300 and reference COSP175
©2011 Panduit Corp.
ALL RIGHTS RESERVED.
WW-COSP175
5/2011