0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FNP1500_10

FNP1500_10

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    FNP1500_10 - Front-Ends & FNR-3 Power Shelves Data Sheet - Power-One

  • 数据手册
  • 价格&库存
FNP1500_10 数据手册
FNP1500/1800 Front-Ends & FNR-3 Power Shelves Data Sheet Features            RoHS compliant for all six substances High density front-ends 15.2 to 18.3 W/in3 Wide input voltage range 85 to 264 VAC 12 V standby voltage, 1A per front-end Highly efficient topology reduces operating costs I2C interface status and control I2C voltage and current limit setting Analog output voltage setting Overtemperature, output overvoltage, and output overcurrent protection ORing circuits for true redundant operation: Vo1: ORing FETs; Vo2: ORing Diodes Status LEDs: AC OK, DC OK, and Fan Fail/Overtemperature Fail FNP1500/1800 front-ends have front-mounted AC input receptacles. Applications     Telecommunications Data communications Servers Distributed power FNR-3 Power Shelf FNR-3 shelves provide up to 5400 watts in a 19" rack. (See the Rack section for power shelf details.) Description The FNP1500/1800 front-ends are power-factor-corrected (PFC) which (depending on model type) provide a 12 VDC or 48 VDC (1500 or 1800 watt) output, and can be used in hot-swap redundant systems. Their very small dimensions allow configuration of up to three units in a 1U rack. The FNP front-ends have a front-mounted AC receptacle. The highly efficient thermal design with internal-fan cooling permits their use over wide temperature ranges and provides very high reliability. Status information is provided with front panel LEDs, logic signals, and via an I2C management interface. In addition, the I2C bus can enable the power supply, set high fan speed, adjust the output voltage, and set the output current limit. The FNP1500/1800's meet international safety standards and display the CE-Mark for the European Low Voltage Directive (LVD). FNR-3-12G and FNR-3-48G power-shelf solutions provide rectification, system management, and power distribution, while maintaining high reliability and offering flexibility for future expansion. The power shelves can be configured with up to three hotswappable 1500 or 1800-watt AC-DC front-ends. MCD10074 Rev. 1.2, 15-Apr-10 Page 1 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelves Data Sheet Model Selection Model FNP1500-12G FNP1500-48G FNP1800-12G Input voltage VAC 1 auto selected 108 – 264 85 – 105 105 – 264 85 – 105 180 – 264 105 – 180 85 – 105 180 – 264 105 – 180 85 – 105 Output 1 Vo1 nom VDC 12 12 48 48 12 12 12 48 48 48 Io1 max ADC 129 @ 11.64V 101.8 @ 11.78A 32.2 25.4 150 @ 11.52V 129 @ 11.64V 101.8A @ 11.78V 39.2 32.2 25.4 Vo2 nom VDC 12 12 12 12 12 12 12 12 12 12 Output 2 Io2 max ADC 1 1 1 1 1 1 1 1 1 1 Rated power W 1512 1212 1512 1212 1740 1512 1212 1812 1512 1212 Compatible 2 Shelf FNR-3-12G FNR-3-48G FNR-3-12G FNP1800-48G 1 2 FNR-3-48G The available output power is automatically adjusted depending on the input voltage. 1U standard racks are available from Power-One. See the Rack (Power Shelf) section of this data sheet for configurations and details. Absolute Maximum Ratings Stress in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-term reliability, or cause permanent damage to the converter. Parameter Input voltage Operating ambient temperature Conditions/Description Continuous Transient, 60 ms max. Vi min-Vi max, Io nom, cooling by internal fan @ 100 % load @ 50 % load Non-Operating 0 0 -40 Min Max 264 300 50 70 85 Unit VAC VAC °C °C °C Storage temperature Environmental, Mechanical, & Reliability Specifications Parameter Altitude Relative humidity, non-condensing Temperature coefficient Shock Sinusoidal vibration Conditions/Description Operating Non-Operating Operating Storage 0 °C to 70 °C (after 15 min warm-up) IEC/EN 60068-2-27, 11 ms IEC/EN 60068-2-6 2-8 Hz 8-200 Hz 200-500 Hz 10-2000 Hz Calculated per Bellcore (SR-332, Issue 1): GB 25 °C GB 25 °C (FNP1500-12G) Demonstrated 230 TBD 250 7.5 2 4 6.15 10 5 Min Nom Max 10 k 40 k 90 95 0.02 40 Unit ASL Ft. ASL Ft. % RH % RH %/K gpk mil gpk gpk grms kh kh kh Random vibration MTBF MCD10074 Rev. 1.2, 15-Apr-10 Page 2 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelves Data Sheet Safety Specifications Maximum electric strength testing is performed in the factory according to EN 550116, IEC/EN 60950, and UL 60950. Input-to-output electric strength tests should not be repeated in the field. Power-One will not honor any warranty claims resulting from electric strength field tests. Parameter Agency approvals Insulation safety rating Conditions/description UL60950, (UL) CSA 60950 (cUL), EN 60950(TÜV), CE Mark for LVD Input to case Input to output Output to case Input to case Input to output Output to case Output 1 to output 2 2.12 1 4.2 0.5 0.1 Basic Reinforced Functional kVDC kVDC kVDC kVDC Min Nom Max Unit Electric strength test voltage 1 Subassemblies are pre-tested with 4.2 kVDC in accordance with EN50116 and IEC/EN60950. EMC Specifications Parameter Electrostatic discharge Electromagnetic field Electrical fast transients/burst Surge Voltage dips and interruptions RF conducted immunity Emissions conducted Emissions radiated Harmonics Voltage fluctuation and flicker Voltage sag Description IEC/EN 61000-4-2, level 4 IEC/EN 61000-4-3, level 3 IEC/EN 61000-4-4, level 3 IEC/EN 61000-4-5, level 3 IEC/EN 61000-4-11 IEC/EN 61000-4-6 CISPR 22/EN 55022/EN 61204 CISPR 22/EN 55022/EN 61204 IEC/EN 61000-3-2 IEC/EN 61000-3-3 SEMI F47-0200 (High Line 230V) Criterion Performance criterion B Performance criterion A Performance criterion B Performance criterion B Performance criterion B or better 10 VAC, AM 80 %, 1 kHz Performance criterion A Class B Class A Class B Pass Pass Input Specifications Specification is valid for input voltage, load, and temperature ranges, unless otherwise stated. Parameter Input voltage Input frequency Turn-on input voltage Turn-off input voltage Inrush current limitation Hold-up time Power factor Efficiency Max input current Input connector 1 Conditions/description Min 85 47 Nom 230 50/60 Max 264 63 85 78 50 Unit VAC Hz VAC VAC Apk ms W/VA Ramping up Ramping down 115/230 VAC acc. ETS 300 132-1 < 100 ms After last AC line peak ,Vi = 230 VAC, Po nom Vi nom, Io nom Vi = 230 VAC, Io nom, TC = 25 °C 79 70 20 0.95 89 1 90 20 % Arms 16A – 20 A / 250 VAC; according to IEC320 C19 87% for FNP1500-12 MCD10074 Rev. 1.2, 15-Apr-10 Page 3 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelves Data Sheet Output Specifications, 12Vout Models Specification is valid for input voltage, load, and temperature ranges, unless otherwise stated. Parameter Nominal output voltage Output voltage set point accuracy Output voltage trimming Nominal current output 1 Nominal current output 1 Current limit output 1 FNP1500-12G Conditions/Description Io = 64.5 A Vi = 230 VAC, Io1 = 65.5 A, TC = 25 °C (Factory setting) Adjustable via I C (Vo1 set) Adjustable via Margin pin (R input) Io1 nom @ Vi =108 VAC – 264 VAC, Po 1.5 kW Io1 nom @ Vi = 85 VAC – 105 VAC, Po 1.2 kW Io1 nom @ Vi =108 VAC – 264 VAC, Po 1.75 kW Io1 nom @ Vi =108 VAC – 180 VAC, Po 1.5 kW Io1 nom @ Vi = 85 VAC – 105 VAC, Po 1.2 kW Io1 max @ Vi = 108 VAC – 264 VAC droop hiccup Io1 max @ Vi = 85 VAC – 105 VAC droop hiccup Io1 max @ Vi = 180 VAC – 264 VAC high droop Io1 lim @ Vi = 180 VAC – 264 VAC hiccup Io1 max @ Vi = 108 VAC – 180 VAC high droop Io1 lim @ Vi = 108 VAC – 180 VAC hiccup Io1 max @ Vi = 85 VAC – 105 VAC high droop Io1 lim @ Vi = 85 VAC – 105 VAC hiccup Io2 nom @ Vi = 85 VAC – 265 VAC, Po 12 W Io2 max @ Vi = 85 VAC – 265 VAC Vi min - Vi max, 50 % Io nom, Ta = 25 °C Vi = 230 V, 5 - 100 % Io nom Full load to no load [0..129 A] at Vo set = 12V dVo1 over the setting range [7 to 13V] -0.5 11.64 -0.36 - 5.58 12 FNP1500-12G 2 Min 11.93 -0.42 7 6.2 Nom 12 12 12 129.0 101.8 150.0 129.0 101.8 147.4 120.2 156.4 168.4 135.4 147.4 108.2 120.2 1.0 1.5 Max 12.05 +0.42 13 Vo1 set 129.0 1 Units VDC VDC % Vo1 nom VDC VDC ADC ADC ADC ADC ADC ADC ADC ADC ADC ADC ADC ADC ADC FNP1800-12G 150.0 FNP1500-12G FNP1800-12G Current limit output 1 Nominal current output 2 Current limit output 2 Static line regulation output 1 Static load regulation output 1 (droop characteristic) Static load regulation output 1 (droop characteristic) 1.0 0.5 12.36 +0.36 ADC ADC % Vo nom mV/A VDC VDC mV/A VDC VDC FNP1800-12G Vi = 230 V, 5 - 100 % Io nom Full load to no load [0..150 A] at Vo set = 12V dVo1 over the setting range [7 to 13V] 11.52 -0.48 - 5.58 12 12.36 +0.36 Static load regulation output 2 (droop characteristic) Full load to no load @ Vi = 85 VAC – 265 VAC Load change 50 % 100 % Io nom, dIo/dt =1A/s Voltage deviation (droop + over- or undershoot) 0.4 VDC Dynamic load regulation FNP1500-12G & FNP1800-12G FNP1500-12G & FNP1800-12G Max. recovery time to within 1% of Vo1 nom Difference in current between two units for Vo1 above 10 % load. FNP1500-12G FNP1800-12G Time required for output within regulation after initial application of AC-input (Vi nom, Io nom) after removal of inhibit (Vi nom, Io nom) Vi nom, Io nom, 20 MHz bandwidth Vo1 Vo2 -2 2 400 % Vo nom s Current Share 12.9 15 1.5 100 120 120 500 ADC ADC s ms mVpp mVpp mV Start-up time Output voltage ripple and noise (Filter 10nF/10µF) Remote sense 1 Total compensation for cable losses FNP1800-12G max is 12V. MCD10074 Rev. 1.2, 15-Apr-10 Page 4 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelf Data Sheet Output Specifications, 48Vout Models Specification is valid for input voltage, load, and temperature ranges, unless otherwise stated. Parameter Nominal output voltage Vo1 Nominal output voltage Vo2 Output voltage set point accuracy Output voltage trimming 2 (via I C or with external resistor) FNP1500-48G Nominal current output 1 FNP1800-48G Conditions/Description Io = 16.1 A Io = 0.5 A Vi = 230 VAC, Io1 =16.1 A, TC = 25 °C (47.8 - 48.2 VDC) Adjustable (44.16 to 51.84 VDC) Io1 nom @ Vi =105 VAC – 264 VAC, Po 1.5 kW Io1 nom @ Vi = 85 VAC – 105 VAC, Po 1.2 kW Io1 nom @ Vi =180 VAC – 264 VAC, Po 1.8 kW Io1 nom @ Vi =105 VAC – 180 VAC, Po 1.5 kW Io1 nom @ Vi = 85 VAC – 105 VAC, Po 1.2 kW Io1 max @ Vi = 105 VAC – 264 VAC Io1 max @ Vi = 85 VAC – 105 VAC Io1 max @ Vi = 180 VAC – 264 VAC Io1 max @ Vi = 105 VAC – 180 VAC Io1 max @ Vi = 85 VAC – 105 VAC Io2 max @ Vi = 85 VAC – 264 VAC Vi min - Vi max, 50 % Io nom Vi = 230 V, 5-100 % Io nom Vo : full load (32.2 ADC) to no load Vi = 230 V, 5-100 % Io nom Vo : full load (32.2 ADC) to no load Vi = 230 V, 5-100 % Io nom Vo : full load (32.2 ADC) to no load Load change 50 % 100 % Io nom, dIo/dt =1 A/s Voltage deviation (droop + over- or undershoot) FNP1500-48G FNP1800-48G All models Current Share Start-up time Max. recovery time to within 1 % of Vo1 nom Difference in current between two units for Vo1 above 10 % load. FNP1500-48G FNP1800-48G Time required for output within regulation after initial application of AC-input (Vi nom, Io nom) after removal of inhibit (Vi nom, Io nom) Vi nom, Io nom, 20 MHz bandwidth Vo1 Vo2 Total compensation for cable losses 3.2 3.9 1.5 100 480 120 500 ADC ADC s ms mVpp mVpp mV -5 -5.7 5 5.7 400 -0.5 46.54 45.91 90.1 48 90.1 48 0.4 droop hiccup droop hiccup droop hiccup droop hiccup droop hiccup -0.5 -8 32.2 25.4 39.2 32.2 25.4 36.8 30 43.8 36.8 30 1.0 1.5 0.5 49.44 49.44 1.0 39.2 Min Nom 48 12 +0.5 +8 Max Units VDC VDC % Vo1 nom % Vo1 nom ADC ADC ADC ADC ADC ADC ADC ADC ADC ADC ADC ADC % Vo nom mV/A VDC mV/A VDC VDC % Vo nom % Vo nom % Vo nom s FNP1500-48G Current limit output 1 FNP1800-48G Nominal current output 2 Current limit output 2 Static line regulation output 1 Static load regulation output 1 (droop characteristic) FNP1500-48G FNP1800-48G Io2 nom @ Vi = 85 VAC – 264 VAC, Po 12 W Static load regulation output 2 (droop characteristic) Dynamic load regulation Output voltage ripple and noise (Filter 10 nF/10 µF) Remote sense MCD10074 Rev. 1.2, 15-Apr-10 Page 5 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelf Data Sheet Protection Parameter Input fuse Inrush current limitation Output Overvoltage protection latching Overtemperature protection 1 1 Conditions/Description Not user accessible Min Nom 25A, fast blow With NTCs Max Unit Tracking Absolute for 48V models Absolute for 12V models Automatic power shutdown at TC No-load -, short circuit - and overload proof 115 122 % Vo nom V 59.5 V 16.85 95 °C Remove input voltage to reset. Control Specification is valid for input voltage, load, and temperature ranges, unless otherwise stated. Parameter Status Indication I C digital bus PS present pin PS remote shutdown / Inhibit pin Power supply OK (I C) DC current fail (I C) 2 1 2 1 2 Conditions/Description LEDs: DC OK (green), AC OK (green); fan fail and overtemperature (amber) Monitors alarm functions and sets parameters Contact closure to logic ground ( internal pull-down resistor of 1 kΩ) TTL compatible signal, inhibited when open contact, high or at TTL logic “1”. Signal referenced to logic return (LRTN) AC OK & DC OK & no overcurrent & no overtemperature & fans working Overcurrent on Io1 Provides a warning that the input power has failed at least 5 ms before the output falls out of regulation ( 110% of Vo1 set, measured in front of the ORing FETs. A green LED on the front panel indicates normal operation. The LED will flash if in parallel operation Vo1 is OK, but the unit is disabled. 2 I C critical temperature warning: Indicates that the operating temperature has reached [Tshut-down – 10K] 2 I C & OC overtemperature warning: Indicates if the unit is in overtemperature shutdown. Open collector signal with 20 mA pull-down capability, referenced to logic return (LRTN). The OC-output will go low 100 ms before an overtemperature condition shuts down the unit. An amber LED on the front panel indicates overtemperature or fan fail. Monitors the voltage Vo1 at the output connector. Accuracy ± 0.45 V over setting range, temperature and load. Monitors the output current Io1 : Accuracy ± 0.4A over the load range. Output voltage trimming Vo1: ± 8 % of Vo set 2 Setting accuracy over I C: ± 50mV at Vo nom, ± 150 mV over setting range Two fan speed levels automatically set depending on the internal temperature. The fan speed can be set to full speed or automatic control. Indicates if the fans are operating or have failed. Overcurrent signal which can be used for synchronous startup of units in parallel or to recover from an overload condition. (See application note). 2 AC fail / Power down warning 2 2 (I C & OC) DC fail / Output voltage fault 2 2 (I C & OC) Temperature warning (I C & OC) 2 2 DC voltage monitoring (I C) DC current monitoring (I C) DC voltage trimming 2 1 (I C or external resistor) Fan speed control (I C) Fan OK (I C & OC) Synch. startup pin 1 2 2 2 2 2 2 1 2 2 1 1 Detailed I C information is available from the model’s I C Manual found on the Power-One web site. Provided over the I C interface and as an open collector signal on the output connector (OC). MCD10074 Rev. 1.2, 15-Apr-10 Page 6 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelf Data Sheet Output Connector Pinning and Signal Specification Output Connector Description Overtemperature / Fan Fail AC Fail / Power down warning Power Supply Present DC Fail / Output voltage fault Internal ground ADDR0, I C address bus 2 ADDR1, I C address bus ADDR2, I C address bus 2 ADDR3, I C address bus ADDR4, I C address bus DATA, I C data line CLOCK, I C clock line Vo2 + output Vo2 – output Logic ground 2 2 2 2 2 Pin Location U1 U2 U3 U4 U5 T1 T2 T3 T4 T5 S1 S2 S3 S4 S5 Type OC-output, protected by 16 V Zener diode and a 10 Ω resistor in series, referenced to logic GND OC-output, protected by 16 V Zener diode and a 10 Ω resistor in series, referenced to logic GND Resistor (1 kΩ) connected to logic GND OC-output, protected by 16 V Zener diode and a 10 Ω resistor in series, referenced to logic GND Internal ground (Vo1– line before the output filter). Do not connect the internal grounds in systems with several units. DIP switch or wire to internal ground, Internally pull up to 5V (10 kΩ). DIP switch or wire to internal ground, Internally pull up to 5V (10 kΩ). DIP switch or wire to internal ground, Internally pull up to 5V (10 kΩ). DIP switch or wire to internal ground, Internally pull up to 5V (10 kΩ). DIP switch or wire to internal ground, Internally pull up to 5V (10 kΩ). I C compatible signal referenced to logic GND 2 I C compatible signal referenced to logic GND Auxiliary power pin, insulated from main output Auxiliary ground pin, insulated from main output Internally connected over 10 Ω to Auxiliary GND. Wire separately form Auxiliary - and main output GND to 2 minimize noise on signals and I C. Leave open if not used. PS active when pulled low (DC-DC stage off when left open) Referenced to logic GND Open or connected to Vo1+ at the load (Internally connected to Vo1+ over 100 Ω) Open or connected to Vo1- at the load (Internally connected to Vo1- over 100 Ω) Open or connected over resistor to internal ground. Do not connect the margin pins in systems with several units. Open or connected to internal ground (+8 % Vo1) or V sense+ (-8 % Vo1) Do not connect the margin pins in systems with several units. Open or connected to synch startup circuit, referenced to Vo1 - at the output connector Open or connected to synch startup circuit, referenced to Vo1 - at the output connector Main output + pins Main output – pins Main output + pins Main output – pins 2 Low level High level < 0.4 V @ 20 mA Pull up < 0.4 V @ 20 mA Pull up Open Pull up < 0.4 V @ 20 mA Pull up V max I max 15 V 20 mA 15 V 20 mA 10 V 10 mA 15 V 20 mA Switch closed Switch open Switch closed Switch open Switch closed Switch open Switch closed Switch open Switch closed Switch open 5 V or 3.3 V logic 5 V or 3.3 V logic 5V 5V 5V 5V 5V Output inhibit V sense + V sense 12V models Output margin 48V models R1 R2 R3 R4 < 0.8 V > 2.0 V 10 V 3.5 mA dU < 3 Vpp 30 mA dU < 3 Vpp 30 mA 3 VDC 60 VDC R4 12V models Synch. startup 48V models Vo1 + output 12V models Vo1 – output 12V models Vo1 + output 48V models Vo1 – output 48V models R5 R5 P2, P4, P6, P8, P10, P12 P1, P3, P5, P7, P9, P11 P2, P4, P6 P1, P3, P5 12V 3mA 12V 2mA MCD10074 Rev. 1.2, 15-Apr-10 Page 7 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelf Data Sheet Mechanical Data (FNP1500/1800 12V Models) Mechanical Data (H, W, D) 5.6” (141.2mm) x 1.6” (40.5mm) x 11” (279.4mm) FNP1500/1800 12V Model Output Connector Descriptions Rear View Female Connector: FCI (51732-026 LF) Mates with: 90° output connector type: 180° output connector type: Part No. FCI (manufacturer): 51762-11202000AA LF Part No. FCI (manufacturer): 51742-11202000AA LF Locate information on availability of FCI connectors at http://www.stkcheck.com/evs/fcielectronics/fcisearch.asp Connector drawings available at: http://portal.fciconnect.com/portal/page/portal/FcicntPublic/DocSrchCustDraw IEC AC power cord with C19 connector VDE 16A: Interpower Components Ltd. 70009110250 IEC AC power cord with C19 connector UL 20A: Interpower Components Ltd. 70025110250 MCD10074 Rev. 1.2, 15-Apr-10 Page 8 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelf Data Sheet Mechanical Data (FNP1500/1800 48V Models) Mechanical Data (H, W, D) 5.6” (141.2mm) x 1.6” (40.5mm) x 11” (279.4mm) FNP1500/1800 48V Model Output Connector Descriptions Rear View Female Connector: FCI (51732-020 LF) Mates with: 90° output connector type: 180° output connector type: Part No. FCI (manufacturer): 51762-10602000AA LF; Power-One Part No.: ZES258-G Part No. FCI (manufacturer): 51742-10602000AA LF Locate information on availability of FCI connectors at http://www.stkcheck.com/evs/fcielectronics/fcisearch.asp Connector drawings available at: http://portal.fciconnect.com/portal/page/portal/FcicntPublic/DocSrchCustDraw IEC AC power cord with C19 connector VDE 16A: Interpower Components Ltd. 70009110250 IEC AC power cord with C19 connector UL 20A: Interpower Components Ltd. 70025110250 MCD10074 Rev. 1.2, 15-Apr-10 Page 9 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelf Data Sheet Paralleling Front-Ends: For parallel use in minimal configuration systems, only the inhibit pins must be shorted to logic GND. All other pins can be left open. The power supplies will share the output current automatically (droop current share). 2 For parallel applications without I C bus, but the use of all other features, it is recommended to connect all logic GND’s on a backplane together, to connect all Vo2 -, all V o2 + and to leave the internal GND’s open. The sense wires can be left open or connected to a common load point, the synch-start pin can be left open or connected to a 2 synch-start circuit, the inhibit pins can be connected together or used individually. All I C signals (T1-T5, S1, and S2) can be left open. Use of a small foil capacitor > 3µF directly at the power outputs of each unit is recommended in order to prevent voltage drops at the hot plug. For additional information on paralleling see the following Rack (Power Shelf) section. Racks (FNR-3-12G and FNR-3-48G Power Shelves) Each rack (power shelf) is 1U high with backplane and designed for up to three front-end models in parallel or in n+1 operation. Each power shelf has:  Massive copper bus bars for low-loss current distribution.  Output terminals with two M4-screws on each power tab.  Two fast-on contacts for system earthing.  Address coding over five pole DIP switch on each unit, 37-pin D-Sub connector with I2C-lines, monitoring signals and support functions.  Provides a start-up synchronization circuit and EMV filters. FNR-3-12G and FNR-3-48G Power Shelf Front View Overall Mechanical Dimensions (FNR-3-12G and FNR-3-48G Power Shelves) FNR-3 Mechanical Data (W, H, D) 17.7” (449.6 mm) x 1.7” (43.1 mm) x 13” (330.2 mm) MCD10074 Rev. 1.2, 15-Apr-10 Page 10 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelf Data Sheet Output Connector Descriptions (FNR-3-12G and FNR-3-48G) A B C D E F G H I Location A B C D E F G H I Description 5-Bit DIP switch for I2C addressing of PSU 1 Earth connection Earth connection Earth connection Output 1 minus Output 1 plus 5-Bit DIP switch for I2C addressing of PSU 2 37-pin SUB-D connector, controlling and auxiliary power (output 2) 5-Bit DIP switch for I2C addressing of PSU 3 MCD10074 Rev. 1.2, 15-Apr-10 Page 11 of 17 www.power-one.com FNP1500/1800 Front-Ends & FNR-3 Power Shelf Data Sheet SUB-D Output Connector Pinout and Signal Specification Output Connector Description Overtemperature / Fan Fail PSU1 Power Supply Present PSU 1 Power Supply Present PSU 2 Open Overtemperature / Fan Fail PSU 3 AC Fail / Power down warning PSU 3 Power Supply Present PSU 3 DC Fail / Output voltage fault PSU 3 Overtemperature / Fan Fail PSU 2 Pin Location 1 2 3 4 5 6 7 8 9 Type OC-output, protected by 16 V Zener diode and a 10 Ω resistor in series, referenced to logic GND Resistor (1 kΩ) connected to logic GND Resistor (1 kΩ) connected to logic GND Low level High level
FNP1500_10 价格&库存

很抱歉,暂时无法提供与“FNP1500_10”相匹配的价格&库存,您可以联系我们找货

免费人工找货