0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HN29V102414T-50

HN29V102414T-50

  • 厂商:

    RENESAS(瑞萨)

  • 封装:

  • 描述:

    HN29V102414T-50 - 1G AND type Flash Memory More than 32,113-sector (542,581,248-bit) x 2 - Renesas T...

  • 数据手册
  • 价格&库存
HN29V102414T-50 数据手册
To all our customers Regarding the change of names mentioned in the document, such as Hitachi Electric and Hitachi XX, to Renesas Technology Corp. The semiconductor operations of Mitsubishi Electric and Hitachi were transferred to Renesas Technology Corporation on April 1st 2003. These operations include microcomputer, logic, analog and discrete devices, and memory chips other than DRAMs (flash memory, SRAMs etc.) Accordingly, although Hitachi, Hitachi, Ltd., Hitachi Semiconductors, and other Hitachi brand names are mentioned in the document, these names have in fact all been changed to Renesas Technology Corp. Thank you for your understanding. Except for our corporate trademark, logo and corporate statement, no changes whatsoever have been made to the contents of the document, and these changes do not constitute any alteration to the contents of the document itself. Renesas Technology Home Page: http://www.renesas.com Renesas Technology Corp. Customer Support Dept. April 1, 2003 Cautions Keep safety first in your circuit designs! 1. Renesas Technology Corporation puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures such as (i) placement of substitutive, auxiliary circuits, (ii) use of nonflammable material or (iii) prevention against any malfunction or mishap. Notes regarding these materials 1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corporation product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corporation or a third party. 2. Renesas Technology Corporation assumes no responsibility for any damage, or infringement of any third-party's rights, originating in the use of any product data, diagrams, charts, programs, algorithms, or circuit application examples contained in these materials. 3. All information contained in these materials, including product data, diagrams, charts, programs and algorithms represents information on products at the time of publication of these materials, and are subject to change by Renesas Technology Corporation without notice due to product improvements or other reasons. It is therefore recommended that customers contact Renesas Technology Corporation or an authorized Renesas Technology Corporation product distributor for the latest product information before purchasing a product listed herein. The information described here may contain technical inaccuracies or typographical errors. Renesas Technology Corporation assumes no responsibility for any damage, liability, or other loss rising from these inaccuracies or errors. Please also pay attention to information published by Renesas Technology Corporation by various means, including the Renesas Technology Corporation Semiconductor home page (http://www.renesas.com). 4. When using any or all of the information contained in these materials, including product data, diagrams, charts, programs, and algorithms, please be sure to evaluate all information as a total system before making a final decision on the applicability of the information and products. Renesas Technology Corporation assumes no responsibility for any damage, liability or other loss resulting from the information contained herein. 5. Renesas Technology Corporation semiconductors are not designed or manufactured for use in a device or system that is used under circumstances in which human life is potentially at stake. Please contact Renesas Technology Corporation or an authorized Renesas Technology Corporation product distributor when considering the use of a product contained herein for any specific purposes, such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use. 6. The prior written approval of Renesas Technology Corporation is necessary to reprint or reproduce in whole or in part these materials. 7. If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a license from the Japanese government and cannot be imported into a country other than the approved destination. Any diversion or reexport contrary to the export control laws and regulations of Japan and/or the country of destination is prohibited. 8. Please contact Renesas Technology Corporation for further details on these materials or the products contained therein. HN29V102414 Series 1G AND type Flash Memory More than 32,113-sector (542,581,248-bit) × 2 ADE-203-1265B (Z) Rev. 1.0 Jan. 25, 2002 Description The Hitachi HN29V102414 Series is a CMOS Flash Memory with AND type multi-level memory cells. It has fully automatic programming and erase capabilities with a single 3.0 V power supply. The functions are controlled by simple external commands. To fit the I/O card applications, the unit of programming and erase is as small as (2048 + 64) bytes. Initial available sectors of HN29V102414 are more than 64,226 (98% of all sector address) and less than 65,536 sectors. Features • On-board single power supply (VCC): VCC = 2.7 V to 3.6 V • Organization  AND Flash Memory: (2048 + 64) bytes × (More than 32,113 sectors) × 2  Data register: (2048 + 64) bytes × 2 • Multi-level memory cell  2 bit/per memory cell • Automatic programming  Sector program time: 1.0 ms (typ)  System bus free  Address, data latch function  Internal automatic program verify function  Status data polling function • Automatic erase  Single sector erase time: 1.0 ms (typ)  System bus free  Internal automatic erase verify function  Status data polling function HN29V102414 Series • Erase mode  Single sector erase ((2048 + 64) byte unit) • Fast serial read access time:  First access time: 50 µs (max)  Serial access time: 50 ns (max) • Low power dissipation:  ICC1 = 2 mA (typ) (Read) (1-chip operation) ICC1 = 4 mA (typ) (Read) (2-chip operation)  ICC2 = 20 mA (max) (Read) (1-chip operation) ICC2 = 40 mA (max) (Read) (2-chip operation)  ISB2 = 50 µA (max) (Standby) (1-chip operation) ISB2 = 100 µA (max) (Standby) (2-chip operation)  ICC3/ICC4 = 40 mA (max) (Erase/Program) (1-chip operation) ICC3/ICC4 = 80 mA (max) (Erase/Program) (2-chip operation)  ISB3 = 20 µA (max) (Deep standby) (1-chip operation) ISB3 = 40 µA (max) (Deep standby) (2-chip operation) • The following architecture is required for data reliability.  Error correction: more than 3-bit error correction per each sector read  Spare sectors: 1.8% (579 sectors)/chip (min) within usable sectors Ordering Information Type No. HN29V102414T-50 Available sector More than 64,226 sectors Package 12.0 × 18.40 mm 2 0.5 mm pitch 48-pin plastic TSOP I (TFP-48DA) 2 HN29V102414 Series Pin Arrangement 48-pin TSOP VCC*2 NC*1, 2 NC*1, 2 NC*1, 2 VSS*2 RES*2 RDY/Busy*2 SC*2 OE*2 I/O0*2 I/O1*2 I/O2*2 I/O3*2 VCC*2 VSS*2 I/O4*2 I/O5*2 I/O6*2 I/O7*2 CDE*2 WE*2 CE*2 NC*1, 2 VSS*2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 (Top view) 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 VCC*3 NC*1, 3 NC*1, 3 NC*1, 3 VSS*3 RES*3 RDY/Busy*3 SC*3 OE*3 I/O0*3 I/O1*3 I/O2*3 I/O3*3 VCC*3 VSS*3 I/O4*3 I/O5*3 I/O6*3 I/O7*3 CDE*3 WE*3 CE*3 NC*1, 3 VSS*3 Note: 1. This pin can be used as the VSS pin. 2. Upper chip. 3. Lower chip. 3 HN29V102414 Series Pin Description Pin name I/O0 to I/O7 CE OE WE CDE VCC* VSS * 1 1 Function Input/output Chip enable Output enable Write enable Command data enable Power supply Ground Ready/ Busy Reset Serial clock No connection RDY/Busy RES SC NC Note: 1. All V CC and VSS pins should be connected to a common power supply and a ground, respectively. 4 HN29V102414 Series Block Diagram Upper chip 2048 + 64 X-decoder 32768 × (2048 + 64) × 8 memory matrix •• I/O0 to I/O7 Data input buffer Input data control Data register (2048 + 64) • • • Multiplexer • • • • • Y-gating Y-decoder Data output buffer RDY/Busy •• • • Y-address counter VCC VSS CE OE WE SC RES CDE Control signal buffer Read/Program/Erase control Lower chip 2048 + 64 X-decoder 32768 × (2048 + 64) × 8 memory matrix •• I/O0 to I/O7 Data input buffer Input data control Data register (2048 + 64) • • • Multiplexer • • • • • Y-gating Y-decoder Data output buffer RDY/Busy •• • • Y-address counter VCC VSS CE OE WE SC RES CDE Control signal buffer Read/Program/Erase control 32113 - 32768 Sector address buffer 32113 - 32768 Sector address buffer ••• ••• 5 HN29V102414 Series Memory Map and Address Sector address 2048 bytes 7FFFH 7FFEH 7FFDH 2048 bytes 2048 bytes 64 bytes 64 bytes 64 bytes 2048 bytes 0002H 0001H 0000H 000H 2048 + 64 bytes 2048 bytes 2048 bytes 64 bytes 64 bytes 64 bytes 800H 83FH Column address Control bytes Cycles SA (1): SA (2): Column address CA (1): CA (2): Address Sector address I/O0 I/O1 I/O2 I/O3 A0 A1 A2 A3 A8 A9 A10 A11 A0 A1 A2 A3 A8 A9 A10 A11 I/O4 A4 A12 A4 × I/O5 I/O6 I/O7 A5 A6 A7 A13 A14 ×*2 A5 A6 A7 × × × First cycle Second cycle First cycle Second cycle Notes: 1. Some failed sectors may exist in the device. The failed sectors can be recognized by reading the sector valid data written in a part of the column address 800 to 83F (The specific address is TBD.). The sector valid data must be read and kept outside of the sector before the sector erase. When the sector is programmed, the sector valid data should be written back to the sector. 2. An × means "Don't care". The pin level can be set to either VIL or VIH, referred to DC characteristics. 6 32113 - 32768 sectors *1 HN29V102414 Series Pin Function CE: CE is used to select the device. The status returns to the standby at the rising edge of CE in the reading operation. However, the status does not return to the standby at the rising edge of CE in the busy state in programming and erase operation. OE: Memory data and status register data can be read, when OE is VIL . WE : Commands and address are latched at the rising edge of WE. SC: Programming and reading data is latched at the rising edge of SC. RES : RES pin must be kept at the VILR (V SS ± 0.2 V) level when VCC is turned on and off. In this way, data in the memory is protected against unintentional erase and programming. RES must be kept at the VIHR (VCC ± 0.2 V) level during any operations such as programming, erase and read. CDE: Commands and data are latched when CDE is VIL and address is latched when CDE is VIH. RDY/Busy: The RDY/Busy indicates the program/erase status of the flash memory. The RDY/ Busy signal is initially at a high impedance state. It turns to a VO L level after the (40H) command in programming operation or the (B0H) command in erase operation. After the erase or programming operation finishes, the RDY/Busy signal turns back to the high impedance state. I/O0 to I/O7: The I/O pins are used to input data, address and command, and are used to output memory data and status register data. Mode Selection Mode Deep standby Standby Output disable Status register read* Command write* 2 1 CE ×* 4 VIH VIL VIL VIL OE × × VIH VIL VIH WE × × VIH VIH VIL SC × × × × VIL RES VILR VIHR VIHR VIHR VIHR CDE × × × × VIL RDY/Busy* 3 I/O0 to I/O7 VOH VOH VOH VOH VOH High-Z High-Z High-Z Status register outputs Din Notes: 1. Default mode after the power on is the status register read mode (refer to status transition). From I/O0 to I/O7 pins output the status, when CE = VIL and OE = VIL (conventional read operation condition). 2. Refer to the command definition. Data can be read, programmed and erased after commands are written in this mode. 3. The RDY/ Busy bus should be pulled up to VCC to maintain the VOH level while the RDY/Busy pin outputs a high impedance. 4. An × means “Don’t care”. The pin level can be set to either VIL or VIH referred to DC characteristics. 7 HN29V102414 Series Command Definition*1, 2 First bus cycle Command Read Bus cycles Serial read (1) (Without CA) 3 (With CA) Serial read (2) Read identifier codes Data recovery read Auto erase Single sector (Without CA*7) (With CA*7) Program (2)*10 Operation Data in mode*3 Write 00H 00H F0H 90H 01H 20H 10H 10H 1FH 0FH 11H 11H FFH 50H 12H Write SA (1)*4 Second bus cycle Operation Data in mode Write Write Write Read Read Write Write Write Write Write Write Write SA (1)*4 SA (1)*4 SA (1)*4 SA (1)*4 SA (1)*4 SA (1)*4 SA (1)*4 SA (1)*4 SA (1)*4 SA (1)*4 ID*8, 9 Recovery data Data out 3 + 2h*6 Write 3 1 1 4 4 Write Write Write Write Write Auto program Program (1) 4 + 2h*6 Write 4 Write Write Write Program (3) (Control bytes)*7 4 Program (4) (WithoutCA*7) 4 (With CA*7) Reset Clear status register Data recovery write 4 + 2h*6 Write 1 1 4 Write Write Write 8 HN29V102414 Series Third bus cycle Command Read Bus cycles Serial read (1) (Without CA) 3 (With CA) Serial read (2) Read identifier codes Data recovery read Auto erase Single sector (Without CA*7) (With CA*7) Program (2)* 10 Fourth bus cycle Operation mode Data in Operation mode Write Data in SA (2)*4 SA (2)*4 SA (2)*4 3 + 2h*6 Write 3 1 1 4 4 Write Write Write Write CA (1)*5 SA (2)*4 SA (2)*4 SA (2)*4 SA (2)* 4 Write Write Write Write Write Write Write B0H*11 40H *11, 12 CA (1) 40H *11, 12 40H *11, 12 40H *11, 12 CA (1) Auto program Program (1) 4 + 2h*6 Write 4 Write Write Write Program (3) (Control bytes)*7 4 Program (4) (WithoutCA*7) 4 (With CA*7) Reset Clear status register Data recovery write SA (2)*4 SA (2)*4 SA (2)*4 4 + 2h*6 Write 1 1 4 Write SA (2)*4 Write 40H *11, 12 9 HN29V102414 Series Fifth bus cycle Command Read Bus cycles Serial read (1) (Without CA) 3 (With CA) Serial read (2) Read identifier codes Data recovery read Auto erase Single sector (Without CA*7) (With CA*7) Program (2)*10 7 Sixth bus cycle Operation mode Data in Operation mode Data in 3 + 2h*6 Write 3 1 1 4 4 4 + 2h*6 Write 4 CA (2)*5 Auto program Program (1) CA (2)*5 Write 40H *11, 12 Program (3) (Control bytes)* 4 Program (4) (WithoutCA*7) 4 (With CA*7) Reset Clear status register Data recovery write 4 + 2h*6 Write 1 1 4 CA (2) Write 40H *11, 12 Notes: 1. Commands and sector address are latched at rising edge of WE pulses. Program data is latched at rising edge of SC pulses. 2. The chip is in the read status register mode when RES is set to VIHR first time after the power up. 3. Refer to the command read and write mode in mode selection. 4. SA (1) = Sector address (A0 to A7), SA (2) = Sector address (A8 to A14). 5. CA (1) = Column address (A0 to A7), CA (2) = Column address (A8 to A11). (0 ≤ A11 to A0 ≤ 83FH) 6. The variable h is the input number of times of set of CA (1) and CA (2) (1 ≤ h ≤ 2048 + 64). Set of CA (1) and CA (2) can be input without limitation. 7. By using program (1) and (3), data can additionally be programmed maximum 15 times for each sector before erase. 8. ID = Identifier code; Manufacturer code (07H), Device code (9DH). 9. The manufacturer identifier code is output when CDE is low and the device identifier code is output when CDE is high. 10. Before program (2) operations, data in the programmed sector must be erased. 11. No commands can be written during auto program and erase (when the RDY/ Busy pin outputs a VOL ). 12. The fourth or sixth cycle of the auto program comes after the program data input is complete. 10 HN29V102414 Series Mode Description Read Serial Read (1): Memory data D0 to D2111 in the sector of address SA is sequentially read. Output data is not valid after the number of the SC pulse exceeds 2112. When CA is input, memory data D (m) to D (m + j) in the sector of address SA is sequentially read. Then output data is not valid after the number of the SC pulse exceeds (2112 to m). The mode turns back to the standby mode at any time when CE is VIH. Serial Read (2): Memory data D2048 to D2111 in the sector of address SA is sequentially read. Output data is not valid after the number of the SC pulse exceeds 64. The mode turns back to the standby mode at any time when CE is VIH. Automatic Erase Single Sector Erase: Memory data D0 to D2111 in the sector of address SA is erased automatically by internal control circuits. After the sector erase starts, the erasure completion can be checked through the RDY/Busy signal and status data polling. All the bits in the sector are "1" after the erase. The sector valid data stored in a part of memory data D2048 to D2111 must be read and kept outside of the sector before the sector erase. Automatic Program Program (1): Program data PD0 to PD2111 is programmed into the sector of address SA automatically by internal control circuits. When CA is input, program data PD (m) to PD (m + j) is programmed from CA into the sector of address SA automatically by internal control circuits. By using program (1), data can additionally be programed 15 times for each sector before the following erase. When the column is programmed, the data of the column must be [FF]. After the programming starts, the program completion can be checked through the RDY/Busy signal and status data polling. Programmed bits in the sector turn from "1" to "0" when they are programmed. The sector valid data should be included in the program data PD2048 to PD2111. Program (2): Program data PD0 to PD2111 is programmed into the sector of address SA automatically by internal control circuits. After the programming starts, the program completion can be checked through the RDY/Busy signal and status data polling. Programmed bits in the sector turn from "1" to "0" when they are programmed. The sector must be erased before programming. The sector valid data should be included in the program data PD2048 to PD2111. Program (3): Program data PD2048 to PD2111 is programmed into the sector of address SA automatically by internal control circuits. By using program (3), data can additionally be programed 15 times for each sector befor the following erase. When the column is programmed, the data of the column must be [FF]. After the programming starts, the program completion can be checked through the RDY/ Busy signal and status data polling. Programmed bits in the sector turn from "1" to "0" when they are programmed. 11 HN29V102414 Series Program (4): Program data PD0 to PD2111 is programmed into the sector of address SA automatically by internal control circuits. When CA is input, program data PD (m) to PD (m + j) is programmed from CA into the sector of address SA automatically by internal control circuits. By using program (4), data can be rewritten for each sector before the following erase. So the column data before programming operation are either "1" or "0". In this mode, E/W number of times must be counted whenever program (4) execute. After the programming starts, the program completion can be checked through the RDY/ Busy signal and status data polling. The sector valid data should be included in the program data PD2048 to PD2111. 32767 Sector address Memory array 0 0 32767 Sector address Memory array 0 32767 Sector address Memory array 0 Register 2111 0 Column address Register 2111 0 2048 Register Serial read (2) Program (3) 2111 Serial read (1) (Without CA) Program (1) (Without CA) Program (2) Serial read (1) (With CA) Program (1) (With CA) Status Register Read The status returns to the status register read mode from standby mode, when CE and O E is VIL. In the status register read mode, I/O pins output the same operation status as in the status data polling defined in the function description. Identifier Read The manufacturer and device identifier code can be read in the identifier read mode. The manufacturer and device identifier code is selected with CDE VIL and V IH, respectively. 12 HN29V102414 Series Data Recovery Read When the programming was an error, the program data can be read by using data recovery read. When an additional programming was an error, the data compounded of the program data and the origin data in the sector address SA can be read. Output data are not valid after the number of SA pulse exeeds 2112. The mode turns back to the standby mode at any time when CE is VIH. The read data are invalid when addresses are latched at a rising edge of WE pulse after the data recovery read command is written. Data Recovery Write When the programming into a sector of address SA was an error, the program data can be rewritten automatically by internal control circuit into the other selected sector of address SA’. Since the data recovery write mode is internally Program (4) mode, rewritten sector of address SA’ needs no sector erase before rewrite. After the data recovery write mode starts, the program completion can be checked through the RDY/Busy signal and the status data polling. 13 HN29V102414 Series Command/Address/Data Input Sequence Serial Read (1) (With CA before SC) Command /Address CDE WE SC Low Data output Data output 00H SA (1) SA (2) CA (1) CA (2) CA (1)' CA (2)' Serial Read (1) (With CA after SC) Command /Address CDE WE SC Low Data output Data output Data output 00H SA (1) SA (2) CA (1) CA (2) CA (1)' CA (2)' Serial Read (1) (Without CA), (2) Command/Address CDE WE SC Low Data output 00H/F0H SA (1) SA (2) Single Sector Erase Command/Address CDE WE SC Low Erase start 20H SA (1) SA (2) B0H 14 HN29V102414 Series Program (1), (4) (With CA before SC) Command /Address CDE WE SC Low Data input Data input Program start 10H/11H SA (1) SA (2) CA (1) CA (2) CA (1)' CA (2)' 40H Program (1), (4) (With CA after SC) Command /Address CDE WE SC Low Data input Data input Data input Program start 10H/11H SA (1) SA (2) CA (1) CA (2) CA (1)' CA (2)' 40H Program (1), (4) (Without CA) Command/Address CDE WE SC Low Data input Program start 10H/11H SA (1) SA (2) 40H Program (2) Command/Address CDE WE SC Low Data input Program start 1FH SA (1) SA (2) 40H 15 HN29V102414 Series Program (3) Command/Address CDE WE SC Low Data input Program start 0FH SA (1) SA (2) 40H ID Read Mode Command/Address CDE WE SC Low Manufacture Device code Manufacture code output output code output 90H Data Recovery Read Mode Command/Address CDE WE SC Low Data output 01H Data Recovery Write Mode Command/Address CDE WE SC Low Program start 12H SA (1) SA (2) 40H 16 HN29V102414 Series Status Transition Deep standby RES 00H/F0H FFH CE 90H FFH CE 20H FFH Sector Erase setup SA (1), SA (2) Sector address input B0H Erase start OE Read (1) / (2) SA (1), SA (2) setup VCC Column address input CA(1) CA(2) Sector address OE, SC input Power off CA(1)' OE CA(2)' SC Read (1) / (2) ID read setup CDE, OE ID read BUSY Status register read Erase finish Column address SC, CDE PD(m) input CA(1) CA(2) CA(1)' to CA(2)' PD(m+j) CE Standby PD0 to 10H SA (1), PD2111 OE 40H Output /11H SA (2) Sector address Program Program Program disable (1)/(4) setup input data input start FFH SC, CDE Program finish Status register read PD0 to 1FH SA (1), PD2111*3 OE 40H /0FH Program (2)/(3) SA (2) Sector address Status register Program Program read input data input setup start SC, CDE FFH Program finish Program error or Status register clear 50H Erase error CE*2 FFH*2 ERROR Data recovery OE, SC Data recovery read setup read SA(1) 1 Error CE Output 12H* Data recovery SA(2) Sector address 40H standby disable write setup input FFH OE Status register read OE Status register read 01H*1 Notes: 1. (01H)/(12H) Data recovery read/write can be used only for Program (1), (2), (3), (4) errors. 2. When reset is done by CE or FFH, error status flag is cleared. 3. When Program (3) mode, input data is PD2048 to PD2111. 17 HN29V102414 Series Absolute Maximum Ratings Parameter VCC voltage VSS voltage All input and output voltages Operating temperature range Storage temperature range Storage temperature under bias Symbol VCC VSS Vin, Vout Topr Tstg Tbias Value –0.6 to +4.6 0 –0.6 to +4.6 0 to +70 –65 to +125 –10 to +80 Unit V V V ˚C ˚C ˚C 3 1, 2 Notes 1 Notes: 1. Relative to VSS . 2. Vin, Vout = –2.0 V for pulse width ≤ 20 ns. 3. Device storage temperature range before programming. Capacitance (Ta = 25˚C, f = 1 MHz) Parameter Input capacitance Output capacitance Symbol Cin Cout Min — — Typ — — Max 6 12 Unit pF pF Test conditions Vin = 0 V Vout = 0 V 18 HN29V102414 Series DC Characteristics (VCC = 2.7 V to 3.6 V, Ta = 0 to +70˚C) Parameter Input leakage current Output leakage current Standby V CC current (1-chip operation) (2-chip operation) (1-chip operation) (2-chip operation) Deep standby VCC current (1-chip operation) (2-chip operation) Operating VCC current (1-chip operation) (2-chip operation) (1-chip operation) (2-chip operation) Operating VCC current (Program) (1-chip operation) (2-chip operation) Operating VCC current (Erase) (1-chip operation) (2-chip operation) Input voltage Symbol Min I LI I LO I SB1 I SB1 I SB2 I SB2 I SB3 I SB3 I CC1 I CC1 I CC2 I CC2 I CC3 I CC3 I CC4 I CC4 VIL VIH Input voltage (RES pin) VILR VIHR Output voltage VOL VOH — — — — — — — — — — — — — — — — –0.3* 2.0 –0.2 VCC – 0.2 — 2.4 1, 2 Typ — — 0.3 0.6 30 60 1 2 2 4 10 20 20 40 20 40 — — — — — — Max 2 2 1 2 50 100 20 40 20 40 20 40 40 80 40 80 0.8 3 Unit µA µA mA mA µA µA µA µA mA mA mA mA mA mA mA mA V Test conditions Vin = VSS to V CC Vout = VSS to V CC CE = VIH CE = VCC ± 0.2 V, RES = VCC ± 0.2 V RES = VSS ± 0.2 V Iout = 0 mA, f = 0.2 MHz Iout = 0 mA, f = 20 MHz In programming In erase VCC + 0.3* V 0.2 VCC + 0.2 0.4 — V V V V I OL = 2 mA I OH = –2 mA Notes: 1. VIL min = –1.0 V for pulse width ≤ 50 ns in the read operation. VIL min = –2.0 V for pulse width ≤ 20 ns in the read operation. 2. VIL min = –0.6 V for pulse width ≤ 20 ns in the erase/data programming operation. 3. VIH max = VCC + 1.5 V for pulse width ≤ 20 ns. If VIH is over the specified maximum value, the operations are not guaranteed. 19 HN29V102414 Series AC Characteristics (VCC = 2.7 V to 3.6 V, Ta = 0 to +70˚C) Test Conditions • • • • • Input pulse levels: 0.4 V/2.4 V Input pulse levels for RES: 0.2 V/VCC – 0.2 V Input rise and fall time: ≤ 5 ns Output load: 1 TTL gate + 100 pF (Including scope and jig.) Reference levels for measuring timing: 0.8 V, 1.8 V 20 HN29V102414 Series Power on and off, Serial Read Mode Parameter Write cycle time Serial clock cycle time CE setup time CE hold time Write pulse time Write pulse high time Address setup time Address hold time Data setup time Data hold time SC to output delay OE setup time for SC OE low to output low-Z OE setup time before read OE setup time before command write SC to output hold OE high to output float WE to SC delay time RES to CE setup time SC to OE hold time SC pulse width SC pulse low time SC setup time for CE CDE setup time for WE CDE hold time for WE VCC setup time for RES RES to V CC hold time CE setup time for RES RDY/Busy undefined for V CC off RES high to device ready CE pulse high time CE , WE setup time for RES RES to CE , WE hold time Symbol t CWC t SCC t CES t CEH t WP t WPH t AS t AH t DS t DH t SAC t OES t OEL t OER t OEWS t SH t DF t WSD t RP t SOH t SP t SPL t SCS t CDS t CDH t VRS t VRH t CESR t DFP t BSY t CPH t CWRS t CWRH Min 120 50 0 0 60 40 50 10 50 10 — 0 0 100 0 15 — 50 0.3 50 20 20 0 0 20 1 1 1 0 — 200 0 0 Typ — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — Max — — — — — — — — — — 50 — 40 — — — 40 — — — — — — — — — — — — 0.3 — — — Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns µs ms ns ns ns ns ns ns µs µs µs ns ms ns ns ns CE = VIH CE = VIH CE = OE = VIL, WE = VIH CE = VIL, WE = VIH 1 2 CE = OE = VIL, WE = VIH CE = VIL, OE = VIH Test conditions Notes 21 HN29V102414 Series Parameter SC setup for WE CE hold time for OE SA (2) to CA (2) delay time RDY/Busy setup for SC Time to device busy Busy time on read mode Symbol t SW t COH t SCD t RS t DB t RBSY Min 50 0 — 200 — — Typ — — — — — 45 Max — — 30 — 150 — Unit ns ns µs ns ns µs Test conditions Notes Notes: 1. t DF is a time after which the I/O pins become open. 2. t WSD (min) is specified as a reference point only for SC, if t WSD is greater than the specified tWSD (min) limit, then access time is controlled exclusively by tSAC. 22 HN29V102414 Series Program, Erase and Erase Verify Parameter Write cycle time Serial clock cycle time CE setup time CE hold time Write pulse time Write pulse high time Address setup time Address hold time Data setup time Data hold time Symbol t CWC t SCC t CES t CEH t WP t WPH t AS t AH t DS t DH Min 120 50 0 0 60 40 50 10 50 10 0 40 100 — — — — — 50 200 20 20 0 30 50 0 20 Typ — — — — — — — — — — — — — — 1.0 1.5 1.0 2.0 — — — — — — — — — Max — — — — — — — — — — — — — 150 10.0 20.0 20.0 30.0 — — — — — — — — — Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ms ms ms ms µs ns ns ns ns ns ns ns ns CDE = VIL Test conditions Note OE setup time before command t OEWS write OE setup time before status polling OE setup time before read Time to device busy Auto erase time Auto program time Program(1), (3) Program(2) Program(4), Data recovery write WE to SC delay time CE pulse high time SC pulse width SC pulse low time Data setup time for SC Data hold time for SC SC setup for WE SC setup for CE SC hold time for WE t OEPS t OER t DB t ASE t ASP t ASP t ASP t WSD t CPH t SP t SPL t SDS t SDH t SW t SCS t SCHW 23 HN29V102414 Series Parameter CE to output delay OE to output delay OE high to output float RES to CE setup time CDE setup time for WE CDE hold time for WE CDE setup time for SC CDE hold time for SC Next cycle ready time CDE to OE hold time CDE to output delay CDE to output invalid CE hold time for OE OE setup time for SC OE low to output low-Z SC to output delay SC to output hold RDY/Busy setup for SC Busy time on read mode Note: Symbol t CE t OE t DF t RP t CDS t CDH t CDSS t CDSH t RDY t CDOH t CDAC t CDF t COH t OES t OEL t SAC t SH t RS t RBSY Min — — — 0.3 0 20 1.5 30 0 50 — — 0 0 0 — 15 200 — Typ — — — — — — — — — — — — — — — — — — 45 Max 120 60 40 — — — — — — — 50 100 — — 40 50 — — — Unit ns ns ns ms ns ns µs ns ns ns ns ns ns ns ns ns ns ns µs 1 Test conditions Note 1. t DF is a time after which the I/O pins become open. 24 HN29V102414 Series Timing Waveforms Power on and off Sequence VCC tVRS CE tRP WE tCWRS RES *1 tBSY RDY /Busy Notes: 1. RES must be kept at the VILR level referred to DC characteristics at the rising and falling edges of VCC to guarantee data stored in the chip. 2. RES must be kept at the VIHR level referred to DC characteristics while I/O7 outputs the VOL level in the status data polling and RDY/Busy outputs the VOL level. 3. : Undefined *2 High-Z Ready tBSY tCES tCEH tCESR tRP tCES tCEH tCESR tCWRH tVRH *1 tDFP 25 HN29V102414 Series Serial Read (1) (2) Timing Waveform *1 tCPH tCWC tWPH tOER *3 CE tCES OE tOEWS WE tCDS CDE tWP tCDS tCDH SC tSCS I/O0 to I/O7 00H /F0H RES tRP RDY /Busy tDB SA(1) SA(2) tDS tDH tAS tAH tAS tAH tOEL tWP tWP tOES tWSD tSCC tSP tSCC *2 tCWC tWPH tCOH tCEH tWP tCDH tSOH tCDS tDS tDH tSPL tSAC tSH tSAC tSH D1out/D2049out tSAC tSAC tDF D0out/D2048out D2111out/D2111out *2 FFH tRBSY tRS High-Z Notes: 1. The status returns to the standby at the rising edge of CE. 2. Output data is not valid after the number of the SC pulse exceeds 2112 and 64 in the serial read mode (1)and (2), respectively. 3. After any commands are written, the status can return to the standby after the command FFH is input and CE turns to the VIH level. Serial Read (1) with CA before SC Timing Waveform h-1 cycle * 5 CE tCES * tCOH 1 tCPH tCWC tWPH tCWC tWPH tCWC tWPH tOEWS tOER tSW tWP tWP tSCD tCDH tWSD tWP tOES tSCC tSP tSCS tDS tDH tAS tAH tAS tAH tAS tAH tAS tAH t tOEL SAC t SH tSPL tSAC tSH D(n+1)out D(n+i)out *2 * tCEH4 OE tOEWS tCWC tWPH tCWC tWPH tOER WE tCDS tWP tCDS t WP tWP tWP tOES tSCC tSCC *3 tSOH tWP tCDH CDE tSCC *2 tSOH tCDS SC tSAC tSAC tDF tAS tAH tAS tAH CA(2)' tSAC tOEL tSP tSPL tSAC tSAC tSH tSH D(m)out D(m+1)out tSAC tDF tDS tDH I/O0 to I/O7 tRP 00H SA(1) SA(2) CA(1) CA(2) D(n)out CA(1)' D(m+j)out *3 FFH RES RDY /Busy tDB tRBSY tRS High-Z Notes: 1. 2. 3. 4. The status returns to the Standby at the rising edge of CE. Output data is not valid after the number of the SC pulse exceeds (2112-n). (i ≤ 2111-n, 0 ≤ n ≤ 2111) Output data is not valid after the number of the SC pulse exceeds (2112-m). (j ≤ 2111-m, 0 ≤ m ≤ 2111) After any commands are written, the status can return to the standby after the command FFH is input and CE turns to the VIH level. 5. This interval can be repeated (h-1) cycle. (1≤ h ≤ 2048 + 64) 26 HN29V102414 Series Serial Read (1) with CA after SC Timing Waveform h cycle* 5 tCOH *1 CE tCES tCPH tCWC tWPH tOER tSW tWP tWP tWP tOES tCDS tWSD tSCC tSCC 2 * tSOH tCDH tCDS tOEWS tCWC tWPH tOER 4 tCEH* OE tOEWS tCWC tWPH WE tWP tWP tOES tSCC tSCC *3 tSOH tWP tCDH CDE tCDS SC tSCS tDS tDH tAS tAH tAS tAH tSAC t t tOEL t SP SPL tSH SAC tSAC tSH tSAC tDF tAS tAH tAS tAH tOEL tRP 00H SA(1) SA(2) D0out D1out D(k)out *2 tSP tSAC tSAC tSPL tSAC tSH tSH D(m)out D(m+1)out tSAC tDF tDS tDH I/O0 to I/O7 CA(1) CA(2) D(m+j)out *3 FFH RES tDB tRBSY RDY /Busy tRS High-Z Notes: 1. 2. 3. 4. 5. The status returns to the Standby at the rising edge of CE. Output data is not valid after the number of the SC pulse exceeds 2112. (0 ≤ k ≤ 2111) Output data is not valid after the number of the SC pulse exceeds (2112-m). (j ≤ 2111-m, 0 ≤ m ≤ 2111) After any commands are written, the status can return to the standby after the command FFH is input and CE turns to the VIH level. This interval can be repeated h cycle. (1≤ h ≤ 2048 + 64) Erase and Status Data Polling Timing Waveform (Sector Erase) CE tCES OE tOEWS WE tCDS CDE tWP tCDS tCDH SC tSCS I/O0 to I/O7 20H RES tRP RDY /Busy High-Z tDB *1 *2 High-Z SA(1) SA(2) B0H IO7 = VOL IO7 = VOH tDS tDH tAS tAH tAS tAH tDS tDH tDF tDF tWP tWP tWP tCDS tCDH tCDH tSCHW tCWC tWPH tCWC tWPH tCWC tWPH tCEH tOEPS tCE tOE tASE tRDY tCDS Notes: 1. Any commands,including reset command FFH, cannot be input while RDY/Busy outputs a VOL. 2. The status returns to the standby status after RDY/Busy returns to High-Z. 27 HN29V102414 Series Program (1) and Status Data Polling Timing Waveform CE tCES OE tOEWS tCWC tWPH WE tCDS CDE tCDH SC tSCS I/O0 to I/O7 10H RES tRP RDY /Busy High-Z *2 SA (1) SA (2) PD0 PD1 PD2111 40H tDB I/O7 = VOL I/O7 = VOH *3 High-Z tDS tDH tAS tAH tAS tAH tSDH tSP tSDS tSP tDS tDH tDF tDF tCDH tSCC tSPL *1 tCDH tSCHW tWPtCDS tWP tWP tCDSS tSW tWP tASP tCWC tWPH tOEPS tOE tRDY tCEH tCE tCDS Notes: 1. 2. 3. 4. The programming operation is not guranteed when the number of the SC pulse exceeds 2112. Any commands, including reset command FFH, cannot be input while RDY/Busy is VOL. The status returns to the standby status after RDY/Busy returns to High-Z. By using program (1), data can be programmed additionally for each sector before erase. 28 HN29V102414 Series Program (1) with CA before SC and Status Data Polling Timing Waveform h–1 cycle*6 CE tCES OE tOEWS tCWC tCWC tWPH tWPH tCWC tWPH tCWC tWPH tSW tCDS t CDE tSCS SC tDS I/O0 to I/O7 10H RES tRP RDY /Busy Notes: 1. 2. 3. 4. 5. 6. High-Z tDB *3 The programming operation is not guaranteed when the number of the SC pulse exceeds (2112 – n).(i ≤ 2111 – n, 0 ≤ n ≤ 2111) The programming operation is not guaranteed when the number of the SC pulse exceeds (2112 – m).(j ≤ 2111 – m, 0 ≤ m ≤ 2111) Any commands, including reset command FFH, cannot be input while RDY/Busy is VOL. The status returns to the standby status after RDY/Busy returns to High-Z. By using program (1), data can be programmed additionally for each sector before erase. This interval can be repeated (h – 1) cycle.(1 ≤ h ≤ 2048 + 64) High-Z*4 SA(1) SA(2) CA(1) CA(2) PD(n) PD(n+1) PD(n+i)*1 CA(1)' CA(2)' PD(m) PD(m+1)PD(m+j)*2 40H I/O7=VOL I/O7=VOH t tDHAS tAH tAS tAH tAS tAH tAS tCDH tCDH tSCC tSPL tSP *1 tSP tCDSH tAH tCDH tAH tSDS tSCC tSPL tSDH *2 tSP tSP tDS t WP CDS tWP tWP tWP tWP tCDSS tCDS tWP tWP tCDSS tWP tSW tCDH tSCHW tDH tDF tDF tASP tCDS tCWC tWPH tCEH tCE tOEPS tOE tRDY WE tAH t tSDS SDH tAS tAS Program (1) with CA after SC and Status Data Polling Timing Waveform h cycle*6 CE tCES OE tOEWS tCWC tCWC tWPH tWPH tSW tCDS tWP tCDS tWP CDE tSCS SC tDS I/O0 to I/O7 10H RES tRP RDY /Busy Notes: 1. 2. 3. 4. 5. 6. High-Z tDB *3 The programming operation is not guaranteed when the number of the SC pulse exceeds 2112.(0 ≤ k ≤ 2111) The programming operation is not guaranteed when the number of the SC pulse exceeds (2112 – m).(j ≤ 2111 – m, 0 ≤ m ≤ 2111) Any commands, including reset command FFH, cannot be input while RDY/Busy is VOL. The status returns to the standby status after RDY/Busy returns to High-Z. By using program (1), data can be programmed additionally for each sector before erase. This interval can be repeated h cycle.(1 ≤ h ≤ 2048 + 64) High-Z*4 SA(1) SA(2) PD0 PD1 PD(k)*1 CA(1) CA(2) PD(m) PD(m+1)PD(m+j)*2 40H I/O7=VOL I/O7=VOH t tDHAS tAH tAS tAH tSDS tCDH tCDH tSCC tSPL tSDH tSP *1 tSP tCDSH tAH tCDH tAH tSCC tSPL tSDH *2 tSP tSP tWP tCDSS tCDS tWP tWP tCDSS tWP tSW tCDH tSCHW tDH tDF tDF tASP tCDS tCWC tWPH tCEH tCE tOEPS tOE tRDY WE tAS tAS tSDS tDS 29 HN29V102414 Series Program (2) and Status Data Polling Timing Waveform CE tCES OE tOEWS tCWC tWPH WE tCDS CDE tCDH SC tSCS I/O0 to I/O7 1FH RES tRP RDY /Busy High-Z *2 SA (1) SA (2) PD0 PD1 PD2111 40H tDB I/O7 = VOL I/O7 = VOH *3 High-Z tDS tDH tAS tAH tAS tAH tSDH tSP tSDS tSP tDS tDH tDF tDF tCDH tSCC tSPL *1 tCDH tSCHW tWPtCDS tWP tWP tCDSS tSW tWP tASP tCDS tCWC tWPH tOEPS tOE tRDY tCEH tCE Notes: 1. 2. 3. 4. The programming operation is not guranteed when the number of the SC pulse exceeds 2112. Any commands, including reset command FFH, cannot be input while RDY/Busy is VOL. The status returns to the standby status after RDY/Busy returns to High-Z. By using program (2), the programmed data of each sector must be erased before programming next data. 30 HN29V102414 Series Program (3) and Status Data Polling Timing Waveform CE tCES OE tOEWS tCWC tWPH WE tCDS CDE tCDH SC tSCS I/O0 to I/O7 0FH RES tRP RDY /Busy High-Z *2 SA (1) SA (2) PD2048 PD2049 PD2111 40H tDB I/O7 = VOL I/O7 = VOH *3 High-Z tDS tDH tAS tAH tAS tAH tSDH tSP tSDS tSP tDS tDH tDF tDF tCDH tSCC tSPL *1 tCDH tSCHW tWPtCDS tWP tWP tCDSS tSW tWP tASP tCDS tCWC tOEPS tOE tRDY tCEH tCE Notes: 1. 2. 3. 4. The programming operation is not guranteed when the number of the SC pulse exceeds 64. Any commands, including reset command FFH, cannot be input while RDY/Busy is VOL. The status returns to the standby status after RDY/Busy returns to High-Z. By using program (3), the data can be programmed additionally for each sector before erase. 31 HN29V102414 Series Program (4) and Status Data Polling Timing Waveform CE tCES OE tOEWS tCWC tWPH WE tCDS CDE tCDH SC tSCS I/O0 to I/O7 11H RES tDB tRP RDY /Busy tRBSY Notes: 1. 2. 3. 4. The programming operation is not guranteed when the number of the SC pulse exceeds 2112. Any commands, including reset command FFH, cannot be input while RDY/Busy is VOL. The status returns to the standby status after RDY/Busy returns to High-Z. By using program (4), data can be rewritten for each sector. tRS tDB High-Z *2 SA (1) SA (2) PD0 PD1 PD2111 40H tDB I/O7 = VOL I/O7 = VOH *3 High-Z tDS tDH tAS tAS tAH tCDH tWSD tAH tSDH tSP tSDS tSP tDS tDH tDF tDF tSCC tSPL *1 tCDH tSCHW tWPtCDS tWP tWP tCDSS tSW tWP tASP tCDS tCWC tWPH tOEPS tOE tRDY tCEH tCE 32 HN29V102414 Series Program (4) with CA before SC and Status Data Polling Timing Waveform h–1 cycle*6 CE tCES OE tOEWS tCWC tCWC tWPH tWPH tCWC tWPH tCWC tWPH tSW tCDS tWP tCDS tWP CDE tSCS SC tDS I/O0 to I/O7 11H RES tRP RDY /Busy Notes: 1. 2. 3. 4. 5. 6. tDB tRBSY tRS High-Z tDB *3 The programming operation is not guaranteed when the number of the SC pulse exceeds (2112 – n).(i ≤ 2111 – n, 0 ≤ n ≤ 2111) The programming operation is not guaranteed when the number of the SC pulse exceeds (2112 – m).(j ≤ 2111 – m, 0 ≤ m ≤ 2111) Any commands, including reset command FFH, cannot be input while RDY/Busy is VOL. The status returns to the standby status after RDY/Busy returns to High-Z. By using program (4), data can be rewritten for each sector. This interval can be repeated (h – 1) cycle.(1 ≤ h ≤ 2048 + 64) High-Z*4 SA(1) SA(2) CA(1) CA(2) PD(n) PD(n+1) PD(n+i)*1 CA(1)' CA(2)' PD(m) PD(m+1)PD(m+j)*2 40H I/O7=VOL I/O7=VOH t tDHAS tAH tAS tAH tAS tAH tAS tCDH tWSD tCDH tSCC tSPL tSP *1 tSP tCDSH tAH tCDH tAH tSDS tSCC tSPL tSDH *2 tSP tSP tDS tWP tWP tWP tCDSS tCDS tWP tWP tCDSS tWP tSW tCDH tSCHW tDH tDF tDF tASP tCDS tCWC tWPH tCEH tCE tOEPS tOE tRDY WE tAH t tSDS SDH tAS tAS Program (4) with CA after SC and Status Data Polling Timing Waveform h cycle*6 CE tCES OE tOEWS tCWC tCWC tWPH tWPH tSW tCDS tWP tCDS tWP CDE tSCS SC tDS I/O0 to I/O7 11H RES tRP RDY /Busy Notes: 1. 2. 3. 4. 5. 6. tDB SA(1) SA(2) PD0 PD1 PD(k)*1 CA(1) CA(2) PD(m) PD(m+1)PD(m+j)*2 40H I/O7=VOL I/O7=VOH t tDHAS tAH tAS tAH tSDS tCDH tCDH tWSD tSCC tSPL tSDH tSP *1 tSP tCDSH tAH tCDH tAH tSCC tSPL tSDH *2 tSP tSP tWP tCDSS tCDS tWP tWP tCDSS tWP tSW tCDH tSCHW tDH tDF tDF tASP tCDS tCWC tWPH tCEH tCE tOEPS tOE tRDY WE tAS tAS tSDS tDS tRBSY tRS High-Z tDB *3 The programming operation is not guaranteed when the number of the SC pulse exceeds 2112.(0 ≤ k ≤ 2111) The programming operation is not guaranteed when the number of the SC pulse exceeds (2112 – m).(j ≤ 2111 – m, 0 ≤ m ≤ 2111) Any commands, including reset command FFH, cannot be input while RDY/Busy is VOL. The status returns to the standby status after RDY/Busy returns to High-Z. By using program (4), data can be rewritten for each sector. This interval can be repeated h cycle.(1 ≤ h ≤ 2048 + 64) High-Z*4 33 HN29V102414 Series ID and Status Register Read Timing Waveform *1 CE tCES OE tOEWS WE tCDS CDE tSCHW SC tSCS I/O0 to I/O7 90H RES tRP RDY /Busy Note: 1. The status returns to the standby at the rising edge of CE. High-Z Manufacturer Device Manufacturer code code code Status register tDS tDH t OE tCDF tCDAC tCDF tCDAC tDF tSCS tOE tDF tCE tWP tCDH tCDOH tOEPS tCOH tCOH *1 34 HN29V102414 Series Data Recovery Read Timing Waveform *1 CE tCES OE tOEWS WE tCDS CDE tWP tCDH tOES tSCC SC tSCS I/O0 to I/O7 01H RES High-Z RDY /Busy Notes: 1. The status returns to the standby at the rising edge of CE. 2. Output data is not valid after the number of the SC pulse exceed 2112 in the recovery data read mode. 3. After any commands are written, the status can turns to the standby after the command FFH is input and CE turns to the VIH level. D0out D1out D2111out High *2 FFH tDS tDH tSP tOEL tSAC tSCC *2 tSOH tCDS tWP tCDH tOER tCPH tCOH tCEH *3 tSPL t t tSH SAC tSH SAC tSAC tDF tDS tDH 35 HN29V102414 Series Data Recovery Write Timing Waveform CE tCES OE tOEWS WE tCDS CDE tWP tCDS tCDH SC tSCS I/O0 to I/O7 12H RES High-Z RDY /Busy tDB *1 *2 High-Z SA(1) High SA(2) 40H IO7 = VOL IO7 = VOH tDS tDH tAS tAH tAS tAH tDS tDH tDF tDF tWP tWP tWP tCDS tCDH tCDH tSCHW tASP tCWC tWPH tCWC tWPH tCWC tWPH tCEH tOEPS tCE tOE tRDY tCDS Notes: 1. Any commands,including reset command FFH, cannot be input while RDY/Busy is VOL. 2. The status returns to the standby status after RDY/Busy returns to High-Z. 36 HN29V102414 Series Clear Status Register Timing Waveform *1 CE tCES OE tOEWS WE tWP tCDH CDE tCDS SC tSCS tDS tDH tDS tDH tSCS tDS tDH tWPH tCDS tWP tCDH tCEH tCPH tCES tOEWS tCDS tWP tCDH I/O0 to I/O7 50H RES High High-Z Next Command Next Command RDY /Busy Note 1. The status returns to the standby at the rising edge of CE. 37 HN29V102414 Series Function Description Status Register: The HN29V102414 outputs the operation status data as follows: I/O7 pin outputs a V OL to indicate that the memory is in either erase or program operation. The level of I/O7 pin turns to a VOH when the operation finishes. I/O5 and I/O4 pins output V OLs to indicate that the erase and program operations complete in a finite time, respectively. If these pins output VOHs, it indicates that these operations have timed out. If I/O6 pin outputs V OH , it indicates a possibility that can be corrected by ECC, choose data correction by ECC or not by reading out the data. When these pins monitor, I/O7 pin must turn to a VOH . To execute other erase and program operation, the status data must be cleared after a time out occurs. From I/O0 to I/O3 pins are reserved for future use. The pins output V OLs and should be masked out during the status data read mode. The function of the status register is summarized in the following table. I/O I/O7 I/O6 I/O5 I/O4 I/O3 I/O2 I/O1 I/O0 Flag definition Ready/ Busy Definition VOH = Ready, VOL = Busy Program/Erase ECC When I/O7 outputs V OH , VOH = ECC available, VOL = ECC not available. check Erase check Program check Reserved Reserved Reserved Reserved VOH = Fail, VOL = Pass VOH = Fail, VOL = Pass Outputs a V OL and should be masked out during the status data poling mode. ECC Applicability I/O7 VOH VOH VOH VOH I/O6 VOH VOL VOH VOL I/O5 VOH VOH VOL VOL I/O4 VOL VOL VOH VOH Needed Not needed. Sector replacement Needed Not needed. Sector replacement System data correction by ECC This device needs to be corrected failure data by ECC on system or Spare sectors, by reading out again the failure sector data when program/erase error occures. 38 HN29V102414 Series Requirement for System Specifications Program/Erase Endurance: 105 cycles Item Usable sectors (initially) Spare sectors (1-chip operation) (2-chip operation) ECC (Error Correction Code) Min 64,226 579 1158 3 Typ — — — — Max 65,536 — — — Unit sector sector sector bit/sector 39 HN29V102414 Series Unusable Sector Initially, the HN29V102414 includes unusable sectors. The unusable sectors must be distinguished from the usable sectors by the system as follows. 1. Check the partial invalid sectors in the devices on the system. The usable sectors were programmed the following data. Refer to the flowchart “Indication of unusable sectors”. Initial Data of Usable Sectors Column address Data 0H to 81FH FFH 820H 1CH 821H 71H 822H C7H 823H 1CH 824H 71H 825H C7H 826H to 83FH FFH 2. Do not erase and program to the partial invalid sectors by the system. START Sector number = 0 Read data Column address = 820H to 825H Sector number = Sector number + 1 Bad sector*2 No Check data*1 Yes No Sector number = 32,767 Yes END Notes: 1. Refer to table "Initial data of usable sectors". 2. Bad sectors are installed in system. The Unusable Sector Indication Flow (1-chip) 40 HN29V102414 Series Requirements for High System Reliability The device may fail during a program, erase or read operation due to write or erase cycles. The following architecture will enable high system reliability if a failure occurs. 1. For an error in read operation: An ECC (Error Correction Code) or a similar function which can correct 3-bits per each sectors is required for data reliability. When error occurs, data must not be corrected by replacing to spare sector. 2. For errors in program or erase operations: The device may fail during a program or erase operation due to write or erase cycles. The status register indicates if the erase and program operation complete in a finite time. When an error occured in the sector, try to reprogram the data into another sector. Avoid further system access to the sector that error happens. Typically, recommended number of a spare sectors are 1.8% (579 sectors/chip (min)) of initial usable 32,113 sectors/chip (min.) by each device. For the reprogramming, do not use the data from the failed sectors, because the data from the failed sectors are not fixed. So the reprogram data must be the data reloaded from the external buffer, or use the Data recovery read mode or the Data recovery write mode (see the “Mode Description” and under figure “Spare Sector Replacement Flow after Program Error”). To avoid consecutive sector failures, choose addresses of spare sectors as far as possible from the failed sectors. In this case, 105 cycles of program/erase endurance is guaranteed. 41 HN29V102414 Series START Program start Set an usable sector Program end Check RDY/Busy Check status Yes No Clear status register Load data from external buffer Data recovery read Data recovery write Program start Set another usable sector Program end Check RDY/Busy Check status Yes Check status: Status register read END No Spare Sector Replacement Flow after Program Error 42 HN29V102414 Series For Errors in program or erase operations The device may fail during a program or erase operation. Failure mode can be confirmed by read out the status register after complete the erase and program operations. There are two failure modes specified by each codes: 1: Status register error flag: I/O6 = V OL Replace sector under the “Spare Sectors Replacement Flow at Status Register I/O6 Read”. Replacement must be applied to one sector(2k bytes) which contains failure bits. 2: Status register error flag: I/O6 = V OH Escape the program data temporary under the “Replacement Flow at Status Register I/O6 Read”. If failure data can be corrected by ECC, do not replace to spare sector. If failure data can not be corrected by ECC, replace to spare sector. Replacement must be applied to one sector(2k bytes) which contains failure bits. START Check status: Status register read Check I/O6: I/O6 output monitor Check ECC: Correct by ECC? Set an usable sector Program start Program end Check RDY/Busy Check status Yes No Check I/O6 VOL Sector Replacement VOH Escape program deta*1 Program end Read error sector Check status Yes No Check ECC Yes No Sector Replacement Program end Check status Yes END No Note: 1. Refer to 'Spare sector replacement flow after program error' to escape the deta. Spare Sectors Replacement Flow at Status Register I/O6 Read 43 HN29V102414 Series Memory Structure bit 32,768 sectors sector byte (8 bits) 2,112 bytes (16,896 bits) Bit: Minimum unit of data. Byte: Input/output data unit in programming and reading. (1 byte = 8 bits) Sector: Page unit in erase, programming and reading. (1 sector = 2,112 bytes = 16,896 bits) Device: 1 device = 32,768 sectors. 44 HN29V102414 Series Package Dimensions HN29V102414T Series (TFP-48DA) Unit: mm 25 12.00 12.40 Max 48 1 0.50 *0.22 ± 0.08 0.08 M 0.20 ± 0.06 0.45 Max 1.20 Max 24 *0.17 ± 0.05 0.125 ± 0.04 18.40 0.80 20.00 ± 0.20 0° – 8° 0.05 ± 0.05 0.50 ± 0.10 Hitachi Code JEDEC EIAJ Mass (reference value) TFP-48DA Conforms Conforms 0.52 g 0.08 *Dimension including the plating thickness Base material dimension 45 HN29V102414 Series Cautions 1. Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Hitachi bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice. Confirm that you have received the latest product standards or specifications before final design, purchase or use. 3. Hitachi makes every attempt to ensure that its products are of high quality and reliability. However, contact Hitachi’s sales office before using the product in an application that demands especially high quality and reliability or where its failure or malfunction may directly threaten human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power, combustion control, transportation, traffic, safety equipment or medical equipment for life support. 4. Design your application so that the product is used within the ranges guaranteed by Hitachi particularly for maximum rating, operating supply voltage range, heat radiation characteristics, installation conditions and other characteristics. Hitachi bears no responsibility for failure or damage when used beyond the guaranteed ranges. Even within the guaranteed ranges, consider normally foreseeable failure rates or failure modes in semiconductor devices and employ systemic measures such as fail-safes, so that the equipment incorporating Hitachi product does not cause bodily injury, fire or other consequential damage due to operation of the Hitachi product. 5. This product is not designed to be radiation resistant. 6. No one is permitted to reproduce or duplicate, in any form, the whole or part of this document without written approval from Hitachi. 7. Contact Hitachi’s sales office for any questions regarding this document or Hitachi semiconductor products. Hitachi, Ltd. Semiconductor & Integrated Circuits Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan Tel: (03) 3270-2111 Fax: (03) 3270-5109 URL http://www.hitachisemiconductor.com/ For further information write to: Hitachi Semiconductor (America) Inc. 179 East Tasman Drive San Jose,CA 95134 Tel: (408) 433-1990 Fax: (408) 433-0223 Hitachi Europe Ltd. Electronic Components Group Whitebrook Park Lower Cookham Road Maidenhead Berkshire SL6 8YA, United Kingdom Tel: (1628) 585000 Fax: (1628) 585200 Hitachi Europe GmbH Electronic Components Group Dornacher Straße 3 D-85622 Feldkirchen Postfach 201,D-85619 Feldkirchen Germany Tel: (89) 9 9180-0 Fax: (89) 9 29 30 00 Hitachi Asia Ltd. Hitachi Tower 16 Collyer Quay #20-00 Singapore 049318 Tel : -538-6533/538-8577 Fax : -538-6933/538-3877 URL : http://semiconductor.hitachi.com.sg Hitachi Asia Ltd. (Taipei Branch Office) 4/F, No. 167, Tun Hwa North Road Hung-Kuo Building Taipei (105), Taiwan Tel : -(2)-2718-3666 Fax : -(2)-2718-8180 Telex : 23222 HAS-TP URL : http://www.hitachi.com.tw Hitachi Asia (Hong Kong) Ltd. Group III (Electronic Components) 7/F., North Tower World Finance Centre, Harbour City, Canton Road Tsim Sha Tsui, Kowloon Hong Kong Tel : -(2)-735-9218 Fax : -(2)-730-0281 URL : http://semiconductor.hitachi.com.hk Copyright © Hitachi, Ltd., 2001. All rights reserved. Printed in Japan. Colophon 5.0 46
HN29V102414T-50 价格&库存

很抱歉,暂时无法提供与“HN29V102414T-50”相匹配的价格&库存,您可以联系我们找货

免费人工找货