LOW VOLTAGE INVERTER TRANSFORMER
Turns Ratio ( + 2% )
PARAMETER Open Circuit Inductance * Leakage Inductance * Interwinding Capacitance (CW/W) * Operating Frequency Primary DC Resistance Secondary DC Resistance Isolation (HI-POT) Power Rating Current Operating Temperature 0 300 10 1 +70 20 0.250 0.300 MIN. 3.0 12 65 TYP.
1CT : 1CT
MAX. UNITS mHy µHy pF KHz ohms ohms VRMS Watts A
0
Designed as Driven NonSaturating Transformer at Rated Voltage, Power and Frequency.
Materials used in construction of this component meet or exceed UL Class B and can be operated up to 1300 C
C
Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test.
PHYSICAL DIMENSIONS in inches (mm)
1.20 (30.5) MAX. 1.00 (25.4) MAX.
SCHEMATIC DIAGRAM
1
.900 (22.86) MAX.
6 5 4
2 3
.500 (12.70) MIN. # 22 AWG Solderable Leads, 6 ea.
.600 (15.24) TYP.
.400 (10.16) TYP.
.800 (20.32)
1
2
3
RHOMBUS INDUSTRIES INC. FSCM NO. 16714
RHOMBUS P/N: T-1074
6 5 4
CUST P/N: DATE: 11/11/97
NAME: SHEET:
1 OF 1
Rhombus Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971